B320_DRAWING_-_PAFP103.pdf

PDF 46 KB Posted

Attached to
Repair Base Fire Systems
Solicitation number
F8R3CE7177AW02-01
Issued by

About this file

B320 DRAWING - 3

View the file

Other files

File Type Posted
MASTER_Q&A_DOCUMENT.pdf PDF
B320_DRAWING_-_PAFP101.pdf PDF
B320_DRAWING_-_PAFP105.pdf PDF
B320_DRAWING_-_PAFP201.pdf PDF
B320_DRAWING_-_PAFP106.pdf PDF
B320_DRAWING_-_PAFP102.pdf PDF
B320_DRAWING_-_PAFP104.pdf PDF
B258_Fire_Alarm_Control_panel__4.jpg JPG image
B258_Fire_Alarm_Control_panel__3.jpg JPG image
B258_Fire_Alarm_Control_panel__5.jpg JPG image
B258_Fire_Alarm_Control_panel__2.jpg JPG image
B258_Fire_Alarm_Control_panel__1.jpg JPG image
B258_Fire_Alarm_Control_panel__6.jpg JPG image
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

24'16'8'4'0 1'2'

SCALE: 1/8" = 1'-0"

SCALE: 1/8"=1'-0"

MANUAL RELEASE STATIONS

FIRE PROTECTION PLAN - DETECTION AND

N

AFFF SYSTEM DETECTION

ZONE No. 2B

(300 Sq. Ft. SPACING)

(125 Sq. Ft. SPACING) ZONE No. 3

AFFF SYSTEM DETECTION

(150 Sq. Ft. SPACING) ZONE No. 1C

AFFF SYSTEM DETECTION

AFFF SYSTEM DETECTION

ZONE No. 2A

(200 Sq. Ft. SPACING)(200 Sq. Ft. SPACING) ZONE No. 1A

AFFF SYSTEM DETECTION

DR

AF

T

CU

RT

AI

N

DR

AF

T

CU

RT

AI

N

NOTES:

ALL HEAT DETECTORS SHALL BE RATE COMPENSATION TYPE, MOISTURE

RESISTANT AND EXPLOSION PROOF.

ALL HEAT DETECTORS SHALL BE SPACED AS INDICATED. DISTANCE

BETWEEN DETECTORS SHALL BE MEASURED ALONG THE ROOF SLOPE.

MONITOR NOZZLE SYSTEM MANUAL RELEASE STATIONS SHALL BE

PROVIDED AS INDICATED.

ALL MANUAL RELEASE STATIONS SHALL BE MOISTURE RESISTANT AND

EXPLOSION PROOF.

ALL MANUAL RELEASE STATIONS SHALL BE MOUNTED 4'-0" A.F.F.

ALL AUDIBLE/VISIBLE DEVICES SHALL BE MOISTURE RESISTANT AND

EXPLOSION PROOF.

ALL AUDIBLE/VISIBLE DEVICES SHALL BE MOUNTED 6'-8" A.F.F.

1.

2.

3.

4.

5.

6.

7.

AFFF SYSTEM DETECTION

(300 Sq. Ft. SPACING) ZONE No. 1B

O 'K O N

C O M P A N Y

R

EM

A R K S

D A

TE

N O

REVISIONS

PROJECT NO.: 9141

DATE:

CHECKED:

DRAWN:

SHEET NUMBER:

En gi ne er s/

D es ig ne rs

P ea ch tr ee S tr ee t N .E

Su it e

A tl an ta G eo rg ia

(4

5-

FU

EL

S

YS

TE

M S

M A

IN

TE

N A N C E D O C K

1s t A

IR

R

EF

U

EL

IN

G W

IN

G

P

IT

TS

B U R G H I N

TE

R N A

TI

O N A L A

IR

P O R T, P

A

P

EN

N

SY

LV

A N

IA

A

IR

N

A

TI

O N A L G U A R D

P R O

JE

C T

JL

SQ

12/5/94

FINAL SUBMITTAL

F.1

5.7

B.5

B.1

7.3

6.7

8.1

5.9

A.5

6.1

H

7.4

6.9

5.3

A.9A B B.3

B.8

C D E F

F.3

G.5

GF.6

F.7

AFFF SYSTEM DETECTION

ZONE No. 2C

(150 Sq. Ft. SPACING)

DRAFT CURTAIN

DRAFT CURTAIN DRAFT CURTAIN

DR

AF

T

CU

RT

AI

N

Model

File details come from the government source that posted it. Updated .