This is a Contract Data Requirements List (DD Form 1423-1) specifying a single data item requirement for a federal contract.

The contract requires submission of a Hydrostatic Test Report (Data Item No. DI-QCIC-82089) for a 42-inch non-metallic expansion joint with retaining rings. The expansion joint must be ordered per ASTM F1123-87(2024) specification and is designed for seawater applications with operating parameters of 40 psig maximum and 21 psig minimum pressure, and 105°F maximum and 60°F minimum temperature. The joint features a 42-inch inside diameter, 12-inch face-to-face flange dimension (±3/16"), and one drilled flange with 38 bolt holes at 1-5/16" diameter (±1/64") on a 47-3/4" (±5/16") bolt circle. The hydrostatic test requirement is 60 psig, and certified test data must be provided. The report must be traceable to material via unique marking and submitted with corresponding material acceptance through the Wide Area Workflow (WAWF) e-Business Suite rather than prior to shipment. Distribution is restricted to DoD and DoD contractors only with administration and operations access effective through 6/25/2026, with other requests referred to COMNAVSEASYSCOM. All containers must be marked per MIL-STD-129 in accordance with DLA Procurement Note C20. The document was prepared by Joseph Berbach and approved by Errnell Quebral on 6/25/2026.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT DATA REQUIREMENTS LIST Form Approved (1 Data Item) OMB No. 0704-0188

The public reporting burden for this collection of information is estimated to average 110 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to the Department of Defense, Executive Services Directorate (0704-0188). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. Please do not return your form to the above organization.

Send completed form to the Government Issuing Contracting Officer for the Contract/PR No. listed in Block E.

A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY:

TDP

TM OTHER

NDTI

X

D. SYSTEM|ITEM E. CONTRACT/PR NO. F. CONTRACTOR

1. DATA ITEM NO. 2. TITLE OF DATA ITEM 3. SUBTITLE 17. PRICE

GROUP

TEST/INSPECTION REPORT

HYDROSTATIC TEST REPORT

4. AUTHORITY (Data Acquisition Document No.) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE 18. ESTIMATED

TOTAL PRICE

DI-QCIC-82089 PER CONTRACT PURCHASING ACTIVITY

7. DD 250 REQ 9. DIST STATEMENT

REQUIRED

10. FREQUENCY 12. DATE OF FIRST SUBMISSION 14. DISTRIBUTION

DD ONE/R SEE BLOCK 16 b. COPIES

8. APP CODE D 11. AS OF DATE 13. DATE OF SUBSEQUENT

SUBMISSION

a. ADDRESSEE DRAFT FINAL

N/A N/A N/A

Reg Repr o

16. REMARKS N4523A 0 1 0

Block 4: 2.a Ensure hydrostatic test report is traceable to material via unique marking.

Block 9: Distribution Statement D. Distribution authorized to DoD and DoD contractors only.

Administration and operations only, effective 6/25/2026. Other U.S. requests shall be referred to COMNAVSEASYSCOM.

Block 12 - Certification/Data Report documentation shall be attached in the Wide Area Workflow (WAWF) e-Business Suite. Acceptance/Rejection of Certification/Data Report documentation will be accomplished with the corresponding material and will not be accomplished prior to shipment of material.

Document No.: 6175-1301

15. Total 0

G. PREPARED BY H. DATE I. APPROVED BY J. DATE

/s/ Joseph Berbach 6/25/2026 /s/ Errnell Quebral 6/25/2026

DD FORM 1423-1, FEB 2001

Page 1 of 1 Pages

MATERIAL ORDERING DATA

Any specification that is referenced in this Material Order Data sheet is required to be to the latest revision at time of award.

IDN: N4523A 6175-1301

ICN: 38VNL25608 KO: S01 KOI: 001

Paragraph 4 Ordering Data

ASTM-F1123, (42 INCH) STANDARD SPECIFICATION FOR NON-METALLIC EXPANSION

JOINTS, dated 31 DECEMBER 1987 (Reapproved 2024)

(From ASTM-F-1123) 4.1 Orders for products under this specification shall include the following information:

4.1.1 Inside diameter of connecting pipes (joint ID): 42”

4.1.2 Face-to-face dimension that is the flange-to-flange dimension into which the expansion joint is to be installed: 12” dia. ± 3/16”

4.1.3 Maximum and minimum operating pressure in pounds-force per square inch gage (pascals): 40 psig max, 21 psig min

4.1.4 Maximum and minimum operating temperature in °F (°C): 105°F max, 60°F min

4.1.5 Flange drilling in accordance with the appendix titled “Common Flange Dimension/Drilling Chart’’ of the Technical Handbook on Rubber Expansion Joints and Flexible Pipe Connectors (herein referred to as the Technical Handbook) or in accordance with special customer requirements. Drill ONE flange only as follows:

42” Dia. Expansion joint w/retaining rings. Quantity Required: 1 EA

Bolt Circle Dia. = 47-3/4” ± 5/16”

Bolt Holes = 38ea. @ 1-5/16” dia. ± 1/64”

4.1.6 Fluid to be handled: seawater

4.1.7 This ASTM specification designation: ASTM F1123-87(2024)

4.1.8 Movement data requirements (including shock or vibratory excursions if applicable):

not required

4.1.9 Design certification burst test if required (see 9.1): not required

4.1.10 Hydrostatic or special tests if required (see 9.2): Required PSIG: 60

4.1.11 Certification of expansion joint if required (see Section 12): not required

4.1.12 Certified detailed drawing of the expansion joint if required (see 12.2): not required

Additional Data requirements: Expansion joint will be hydrostatically tested at 60 psig. Certified test data is required.

All unit, intermediate, and shipping containers must be marked in accordance with MIL-STD-129. Refer to DLA Procurement Note C20 for further instructions.

Prepared By: Joseph Berbach