Exhibit #3 - Generator and Transfer Switch Location and Equipment Details.pdf

PDF 309 KB Posted

Attached to
IFB - GENERATOR REPAIRS FOR SPRINGFIELD HOSPITAL CENTER
Solicitation number
BPM055828
Issued by
Carroll County, Maryland

About this file

This is an exhibit document detailing generator and transfer switch inventory for the Maryland Department of Health's Springfield Hospital Center (SHC) in support of an Invitation for Bid (IFB Number BPM053794) for preventive maintenance and load testing of fifteen emergency generators. The facility operates fifteen emergency generators distributed across multiple buildings including the Administration Building, Central Storeroom, Maintenance Offices, Hitchman Building, Conference Center, Maintenance Shops, Big G Building, C-3 & C-4, M&S Building, McKeldin Building, Food Service Building, Patient's Canteen, Muncie Barn, Salomon Building, and one portable generator. The generators include equipment manufactured by Cummins, Kohler, and Terex Power, with specific model numbers, serial numbers, and engine specifications documented for each unit. The contract scope requires inspection, troubleshooting, load testing, and corrective maintenance to restore reliable generator operation for the facility's emergency power systems.

The exhibit also documents associated automatic transfer switches (ATS) ranging from 70 amperes to 1000 amperes in capacity, manufactured by Cummins, Kohler, and GE, located throughout the facility at various buildings and operational areas. Twelve distinct transfer switch locations are identified with their corresponding amperage ratings and equipment manufacturers. The generators operate at 480 volts, 3-phase, with engines featuring multiple configurations including John Deere and Cummins powerplants. This comprehensive inventory serves as the baseline specification for bidders to understand the scope and technical requirements of the preventive maintenance and load testing services needed to ensure uninterrupted emergency power capability for this state mental health treatment facility.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATE OF MARYLAND

MARYLAND DEPARTMENT OF HEALTH –

SPRINGFIELD HOSPITAL CENTER

(MDH - SHC)

SHC - PREVENTIVE MAINTENANCE AND LOAD TESTING OF

FIFTEEN (15) EMERGENCY GENERATORS

INVENTORY

Page | 1

SPRINGFIELD HOSPITAL CENTER

(MDH - SHC)

SHC - PREVENTIVE MAINTENANCE AND LOAD TESTING OF

FIFTEEN (15) EMERGENCY GENERATORS

IFB NUMBER BPM053794

INVENTORY

Page | 2

Generator Engine Information

Building: Administration Building: Central Storeroom Building: Maintenance Offices

Generator Manufacturer: Cummins Generator Manufacturer: Cummins Generator Manufacturer: Cummins

Generator Model #: GGHE-5656823 Generator Model #: GGFD-5656827 Generator Model #: GGFD-5656833

Generator Serial #: A040593995 Generator Serial #: A040593399 Generator Serial #: A040593397

Engine Model # WSG1068 Engine Model # ESG642 Engine Model # ESG42

Engine Serial # 042520574 Engine Serial # 042K21820 Engine Serial # 04ZK21826

Building: Hitchman Building: Conference Center Building: Maintenance Shops

Generator Manufacturer: Cummins Generator Manufacturer: Cummins Generator Manufacturer: Kohler

Generator Model #: GTA855G3 Generator Model #: DEFH-2278029 Generator Model #: 60RZG

Engine Model #: 25292831 Generator Serial #: L090078181 Generator Serial #:2101538

Building: Big G Building: C-3 & C-4 Building: M&S

Generator Manufacturer: Cummins Generator Manufacturer: Cummins Generator Manufacturer: Cummins

Generator Model #: GGHE-5656836 Generator Model #: GGKB-5656830 Generator Model #: GGKB-5656831

Generator Serial #: A040593403 Generator Serial #: A040593400 Generator Serial #: A040593398

Engine Model # WSG-10681-6005A Engine Model # GTA83G1 Engine Model # GTA8361

Engine Serial # 04-01-076645 Engine Serial # 46358431 Engine Serial # 46358374

Building: McKeldin Building: Food Service's Building: Patient's Canteen

Generator Manufacturer: Cummins Generator Manufacturer: Cummins Generator Manufacturer: Cummins

Generator Model #: GGKB-5656842 Generator Model #: Z15GFBB Generator Model #: GGHE-5656835

Generator Serial #: A040593402 Generator Serial #: KM04H063760 Generator Serial #: A040593396

Engine Model # GTA83G1 Engine Model # GTA85562 Engine Model # WSG-1068I-6005-A

Engine Serial # 46357342 Engine Serial # 25297022 Engine Serial # 04-01-076632

Building: Muncie Barn Building: Salomon Building: Portable Generator

Generator Manufacturer: Kohler Generator Manufacturer: Kohler Generator Manufacturer: Terex Power

SPRINGFIELD HOSPITAL CENTER

(MDH - SHC)

SHC - PREVENTIVE MAINTENANCE AND LOAD TESTING OF

FIFTEEN (15) EMERGENCY GENERATORS

INVENTORY

Page | 3

Generator Model #: 60RZG Generator Model #: 108REZXB Generator Model #: CJ4T7S0

Generator Serial #: 2093568 Generator Spec #: GM99499-GA1 Generator Serial #: 040133889

Generator Serial #: SGM32GML9 Voltage 480 3 Phase

Engine: John Deere

Engine Family #: 1J0XL06.8014

Engine Model #: 4045TF250B 4.5L

Transfer Switches

Item # Manufacturer Equipment Description Location

1 Cummins Cummins Kohler 150 A ATS 150 A ATS 70 A ATS C-3 C-4 Muncie Barn

2 Cummins 70 A ATS 70 A ATS 70 A ATS 70

A ATS

Employee's Home Men's Home Industrial Building McKeldin

3 Cummins 70 A ATS 125 A ATS Admin Building Load

4 Cummins 70 A ATS 70 A ATS 70 A ATS Nurse's Home Jones' Home Spring Rock Cafe

5 Cummins 1000 A ATS Hitchman

6 Cummins 125 A ATS Big G Building

7 Kohler 125 A ATS Maintenance

8 Cummins 225 A ATS M&S Building

9 Cummins 125 A ATS Central Storeroom (old C-K)

10 Cummins 70 A ATS 400 A ATS Food Services Building

11 Kohler 230 A ATS Muncie Barn

12 GE 225 A ATS 100 A ATS 100 A ATS Salomon

IFB NUMBER BPM053794