NF085001.pdf
PDF 1 MB Posted
- Attached to
- Emergency Dry Dock for Z-Drive Repairs Federal contract opportunity
- Solicitation number
- EA-133M-18-RQ-01428
About this file
NF085001
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_04.pdf | ||
| 10021_-_Dry_Docking_REV_1.doc | DOC document | |
| Amendment_03.pdf | ||
| Amendment_02.pdf | ||
| 12351_-_Z-drive_Flush,_Seal_replacement_REV1.doc | DOC document | |
| Amendment_01.pdf | ||
| MOC-300-3.pdf | ||
| 12351_-_Z-drive_Flush,_Seal_replacement.doc | DOC document | |
| RFQ_EA-133M-18-RQ-01428.pdf | ||
| AMC-997-1A.pdf | ||
| NF-241-05__Z_Drive_Tech_Man.pdf | ||
| NF-505-6501097_Standard_Piping_Details.pdf | ||
| 10011_-_General_Requirements.doc | DOC document | |
| NF085002_F,_Docking_Plan.pdf | ||
| 10021_-_Emergency_Dry_Docking_Basic_Spec_.doc | DOC document | |
| AMC-000-1F_.pdf | ||
| AMC-000-2C.doc | DOC document | |
| MOC-631-2D.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT #
NOAA DRAWING NUMBER REVSIZE
SCALE: CAD FILENAME SHT OF
CAGE CODE
DSGN
DWN
CHK
CHK
NOAA APPROVAL
D
C
B
A
C
B
D
A
Seaworthy Systems, Inc.
MARINE ENGINEERS
NAVAL ARCHITECTS TEL: (860) 767-9061
ESSEX, CT 06426
P.O. BOX 965
NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION
OFFICE OF MARINE & AVIATION OPERATIONS
NOAA SHIP NANCY FOSTER
BOOKLET OF GENERAL PLANS
50-ABNA-0-00032
TAR-SSI-021-(02)
NF-085-001 CD
AS SHOWN NF085001-1A 1 7
OYLJ5
JEK
12/03/02
DAR
12/03/02
1. THIS BOOKLET OF GENERAL PLANS WAS DEVELOPED UNDER TAR SSI-021(02)
BASED ON A SHIPCHECK CONDUCTED AT CASCADE GENERAL, INC. IN PORTLAND,
OREGON ON OCTOBER 28-30, 2002, FOLLOWING THE DEMILITARIZATION AND
CONVERSION OF THE EX-USNV AGATE PASS (YTT-12) TO A NOAA RESEARCH
VESSEL.
THIS DRAWING SUPERSEDES REFERENCES NO. 1, 2, 3, AND 4.
LIST OF ABBREVIATIONS
BHD
BU
CG
CONT
DC
DF
DO
ENCAP
EM
FC
FCU
FO
FRZR
FS
FW
FXD
GEN
H
LAV
LKR
MSD
NT
PP
REFER
REFRD
SH
SR
SPLY
SWBD
TBL
TK
V
VL
WC
WDO
WT
WTD
XDCR
XFMR
BULKHEAD
BUREAU
CLEANING GEAR
CONTROLLER
DAMAGE CONTROL
DRINKING FOUNTAIN
DIESEL OIL
ENCAPSULATED
EXPANDED METAL
FILE CABINET
FAN COIL UNIT
FUEL OIL
FREEZER
FIRE STATION
FRESH WATER
FIXED
GENERATOR
HATCH
LAVATORY
LOCKER
MARINE SANITATION DEVICE
NON-TIGHT
PUMP
REFRIGERATOR
REFRIGERATED
SHOWER
STATEROOM
SUPPLY
SWITCHBOARD
TABLE
TANK
VENT
VERTICAL LADDER
WATER CLOSET
WINDOW
WATERTIGHT
WATERTIGHT DOOR
TRANSDUCER
TRANSFORMER
COVER SHEET
OUTBOARD PROFILE
INBOARD PROFILE
HOLD LEVEL
MAIN DECK6
SHT TITLE
INDEX
GENERAL DATA
FOC'SLE DECK, 02 LEVEL AND BRIDGE7
DATE APPDDESCRIPTIONITEMZONESHTREV
REVISIONSGENERAL NOTES
2.
YTT 9 CLASS, GENERAL ARRANGEMENTS - DECKS
YTT 9 CLASS, OUTBOARD PROFILE
YTT 9 CLASS, INBOARD PROFILE
YTT 9 CLASS, GENERAL ARRANGEMENTS - HOLD PLAN
801-6500934
801-6500930
5777-005
801-6500933
NO TITLE DRAWING NO
REFERENCES
A 2 10-B 1 ADDED VESSEL CALL LETTERS 1/31/03
RJH
2 10-C 2 MODIFIED VESSEL COMPLEMENT
MODIFIED BRIDGE CONSOLE355-B7
B 3 20-C 1 ADDED 02 HOUSE & 01 DECK EXTENSION 3/11/06
BECI
4 29-C 2
342-C5
6 49-C 4
555-A7
ADDED 02 HOUSE & 01 DECK EXTENSION
MOD STOREROOM 2-7-4-A
ADDED 02 HOUSE & 01 DECK EXTENSION
ADDED 02 HOUSE & 03 DECK EXTENSION
& 01 DECK EXTENSION59-B
60-D
C ALL - 1 GENERAL REVISION AND UPDATE 8/18/06
BECI
SHT OF
SIZE
SCALE:
MARINE ENGINEERS
NAVAL ARCHITECTS
ESSEX, CT 06426
TEL: (860) 767-9061
Seaworthy Systems, Inc.
PREPARED BY:
NOAA DRAWING NUMBERCAGE CODE
CAD FILENAME
REV
A
B
C
D
A
B
C
D
NF-085-001 B
NF085001-2A 2 7
D OYLJ5
AS SHOWN
11 10 9
916 15 14 13 12 11 10
16 15 14 13 12
GENERAL INFORMATION
LAUNCHED
DELIVERED
CONVERTED
CALL LETTERS
BUILDER
HOMEPORT
HULL
SEPTEMBER 1990
JULY 1991
DECEMBER 2002
CASCADE GENERAL INC., PORTLAND, OR
WTER
McDERMOTT SHIPYARDS INC.
AMELIA, LA
CHARLESTON, SC
WELDED STEEL
COMPLEMENT
OFFICERS
CREW
SCIENTISTS
GENERAL CHARACTERISTICS
LENGTH OVERALL
LENGTH BETWEEN PERPENDICULARS
BEAM (MOLDED)
DEPTH TO MAIN DECK (MOLDED)
DESIGN DRAFT
MOLDED DISPLACEMENT (S.W.)
FRAME SPACING
186'-6"
176'-77
16"
40'-0"
16'-0"
10'-6"
1182.37 L.TONS
24"
ENGINEERING
CUMMINS
CUMMINS
ULSTEIN
OMNITHRUSTER
CUMMINS
OUTBOARD MOTOR
NAVIGATION SCIENTIFIC EQUIPMENT
COMMUNICATIONS ACOUSTICS
ELECTRONICS
LAUNCHES & SMALL BOATS
NOTE: ELECTRICAL SERVICE: 450 VAC 3 PHASE, 220 & 120 VAC SINGLE PHASE, 230 VDC, 120 VDC
TYPE PROPULSION LENGTH QTY
TYPE MANUFACTURER PULL/CAPACITY QTY
SATNAV
GMDSS
GYROCOMPASS
RADAR
EPIRB'S
PORTABLE EMERGENCY TRANSCEIVER
EMERGENCY RADIO AUTOALARM
HF TRANSCEIVERS
VHF/FM TRANSCEIVERS
EMERGENCY GENERATOR (450 VAC)
RHIB (AMBAR AM550)
SHIP'S SERVICE GENERATORS (450 VAC)
Z-DRIVE UNIT
MAIN PROPULSION (GEARED DIESEL)
BOW THRUSTER (ELECTRIC)
DOPPLER SPEED LOG
VERTICAL FISH FINDER
MULTIBEAM ECHO SOUNDER (EM1002)
ACOUSTIC DOPPLER CURRENT PROFILER (ADCP)
SHIPBOARD ENVIRONMENTAL
XBT SYSTEM
ACQUISITION SYSTEM (SEAS)
100 KW
395 KW
300 HP
400 HP
1250 BHP/1800 RPM
18.67 FEET 1
DECK MACHINERY
TYPE MANUFACTURER PULL\CAPACITY QTY
AFT CRANE
A-FRAME
J-FRAME
CT WINCH
COM 15 WINCH
APPLETON MARINE
GOODCRANE.COM
ALLIED SYSTEMS
MARKEY
25,000 LBS
10,000 LBS @ 40ft
440 Sq Ft
SEWAGE WASTE CONTROL
OILY WASTE CONTROL
HOLDING CAPACITY
FLOW RATE
MANUFACTURER
SYSTEM TYPE
SYSTEM TYPE
HOLDING CAPACITY
MANUFACTURER
OILY WATER SEPARATOR
VILLAGE MARINE
___GALLONS
__ GPM
OMNIPURE 12MC
CHT WITH MSD
7,500 GALS
DRY LAB
FRESHWATER SYSTEM
TYPE
EVAPORATOR (ALFA-LAVAL)
JWP-16-C40
295 Sq Ft
HABITABILITY
SCIENTIFIC LABORATORY FACILITIES
TOTAL BUNKS ABOARD
MESS
WET LAB
FOUR BUNK ROOMS
DOUBLE STATEROOM
SINGLE STATEROOM
7 CU. METERS/DAYCAPACITY
UNCONTAMINATED SALT WATER SYSTEM
NOAA DRAWING NUMBER REV
CAD FILENAME SHT OFSCALE:
SIZE CAGE CODE
AA
B
C
D D
B
C
NF-085-001 C
NF085001-3C 3 73/16"=12"
D OYLJ5
OUTBOARD PROFILE
SCALE: 3/16" = 1'-0"
1' 2'
6'4' 16'8' 12'
1520 10 5 02530354045505560657075808590 o o o o o o
B L L
B
PROJ
NOAA DRAWING NUMBER REV
CAD FILENAME SHT OFSCALE:
SIZE CAGE CODE
AA
B
C
D D
B
C
NF-085-001 C
NF085001-4A 4 73/16"=12"
D OYLJ5
E X H
.T R U N
K LAUNDRY
CHAIN
LKR EQUIPMENT
FWD HYDRAULIC
AUX. MACHINERY ROOM ENGINE ROOM MULTI-PURPOSE ROOM MSD SEWAGE TANK VOID
THRUSTER SEACHEST
P A S S A G E
W R W C
P A S S A G E
CO SR
BRIDGE
GRATING LEVEL
HOLD DECK
MAIN DECK
FOCSLE DECK
HOLD DECK
CENTERLINE INBOARD PROFILE
WT
BHD BHD
WT
BHD
WT
BHD
WT
BHD
WT
BHD
WT
BULWARK
BULWARK
SCALE: 3/16" = 1'-0"
1' 2'
6'4' 16'8' 12'
MAIN DECK
02 DECK
BRIDGE DECK
03-16-0-C
02-15-0-L
L
02-24-2-L
STAIR
STAIR
01-22-4-L
01-12-0-L
SR (2)
L
L
01-29-2-L
PASSAGESR (4)
01-32-2-L
01-40-2-Q
DC LKR
(GENERALLY LOOKING TO PORT)
1-9-0-Q 1-7-2-Q 1-2-0-E1-12-2-L
SR (4)
1-19-2-L
SR (4)
1-35-2-C
COMPUTER
L
W R W C
L
SR
Q
U P S
R O O M
1-46-2-Q
WORKSHOP
2-46-0-E 1.5-29-2-A 1.5-21-0-W 2-18-0-V 2-12-0-F
TANK
FUEL OIL
BOW THR.
MOTOR COMP.
2-12-0-E
FOREPEAK VOID
2-2-0-V
VOID
2-29-2-V
VOID
2-21-2-V
2-63-0-E
2-83-0-E
STEERING GEAR
PASSAGEWAY
2-79-0-T
POTABLE WATER
2-71-2-W
.5 T
AZIMUTHING THRUSTER P/S
DIRTY OIL TANK
HATCH
HATCH
RUDDER (CL)
JO SR (2)
02-32-2-L
HEAD
02-29-2-L
90 85 80 75 70 65 60 55 50 45 40 3035 25 20 15 10 5 0
BL LB
48x48 HATCH OVER
1.5-36-1-L REFER
1.5-29-0-T
PASSAGE
UP
1.5-29-2-A
MULTI-PURPOSE ROOM
SHELL @ 5'-9" WL
1.5-21-2-L
EXERCISE ROOM
1.5-21-0-W
SEWAGE TANK
1.5-21-1-A
STORES
SHELL @ MAIN DECK
VOID NO. 2 (P)
2-29-2-V(BLW)
CREW'S LOUNGE
FRZ
2-21-2-V(BLW)
VOID NO.1(P)
MSD
2-12-1-F
F.O. TANK NO.3 (S)
VOID NO.2 (S)
2-29-1-V(BLW)
VOID
1.5-18-0-V
FWD
GEAR RM (C)
2-83-0-E
STEERING
POTABLE WTR
TANK (P)
2-71-2-W
FUEL OIL
TANK NO. 2 (S)
2-71-5-F
PASSAGEWAY
2-71-3-T
POTABLE WTR
TANK (S)
2-71-1-W
STOREROOM
2-71-4-A
2-71-6-F
TANK NO. 2 (P)
FUEL OIL
PASSAGEWAY
2-79-0-T
2-83-2-E
STEERING GEAR RM (P)
STEERING GEAR RM (S)
2-83-1-E
C VESSELL
2-80-2-V
VOID
2-80-1-V
VOID
VOID NO. 2 (C)
2-29-0-V(BLW)
SSDG #2
SSDG #3
SSDG #1
MAIN ENGINE
ENGINEERS OPR STA
2-51-2-F
FUEL OIL TK NO.1 (P)
2-46-2-F
FUEL OIL DAY TK (P)
2-48-2-A
2-60-2-A
ENGINEERS STORES
2-57-2-F (UNDER)
LUBE OIL TANK (P)
1.5-57-2-T
ENGINE ROOM EXHAUST TRUNK (P)
FUEL OIL DAY TK (S)
2-46-3-F
FUEL OIL TK NO.1 (S)
2-51-1-F
BILGE MANIFOLD
BILGE PP NO.3
BILGE PP NO.4
L.O. PP, DIRTY OIL PP
A/C UNIT
B
IL
G E
M A N
IF
O L D
2-46-1-C
SWITCHBOARD
ERC
CONSOLE
FIRE PP
POTABLE WTR TK
SPARE
PARTS RM
ELECTRICAL
ROOM
2-48-1-Q
O.W.S.
FUEL OIL TRANSFER MANIFOLD
FUEL OIL PURIFIER
L.P. AIR
COMPRESSORS
OILY BILGE TANK (S)
2-57-1-W (UNDER)
ENGINE ROOM ESCAPE/EXHAUST TRUNK (S)
1.5-57-2-T
A
IR
R C V R
DIRTY OIL TK
SW/JW PLATE
HEAT EXCHANGER
ENGINE ROOM
2-46-0-E
2-2-0-V
FOREPEAK VOID
VOID NO.1(S)
2-21-1-V(BLW)
REFR
COMPRESSORS
F.O. TANK NO.3 (P)
2-12-2-F
2-12-0-E
MOTOR COMPT
BOW THRUSTER
S.W./GNL.
SVC. PUMP
BROMINATOR
J.W.
EVAP
J.W. CIRC
PUMP
EDUCTOR
PUMP
POTABLE WTR
PRESS. SET
FIRE
PUMP
HEAVY LIFT
CAPSTAN HPU
DIVING AIR
COMPRESSOR
SCBA RACK
UP
UP
SPACE HTR
PLAN VIEW, HOLD
SCALE: 3/16" = 1'-0"
SCALE: 3/16" = 1'-0"
1' 2'
6'4' 16'8' 12'
V L
VL
V L
SLIDING
WTD
SLIDING
WTD
Z-DRIVE
UNIT
MOTOR
HPU
BLOWER
HTR
HTR
BLOWER
HPU
MOTOR
UNIT
Z-DRIVE
VL
2-63-0-E
AUXILIARY MACHINERY ROOM
F.S. #8
WTD
WTD
MOON POOL/
DROP TUBE
NOAA DRAWING NUMBER REV
CAD FILENAME SHT OFSCALE:
SIZE CAGE CODE
AA
B
C
D D
B
C
NF-085-001 C
NF085001-5A 5 73/16"=1'
D OYLJ5
DN
90 85 80 75 70 6065 55 50 45 40 35 30 25 20 15 10 5 0
1-19-2-L
MESS AREA
1-18-1-Q
PLAN VIEW, MAIN DECK
SCALE: 3/16" = 1'-0"
GALLEY
1-28-1-Q
1-27-1-A
STORES
1-15-0-L
PASSAGE
WR/WC
1-31-2-L
1-24-2-A
SUPPLY
SR (4)
1-24-4-L
SR (4)
RECIRC. PP
FCSLE DK (OVER)
FWD
1-12-1-Q
SHIP'S OFFICE
1-15-1-E
WTR HTR &
SR (4)
1-12-2-L
1-9-0-Q
LAUNDRY
LC VESSEL
UP
1-9-2-V
VOID
MED LKR
1-9-1-A
1-7-2-A
CHAIN LOCKER
1-7-1-A
CHAIN LOCKER
FWD HYDRAULIC EQUIPMENT RM
1-2-0-E
1-57-1-T
ACCESS
UP
BOAT & DECK
1-58-2-A
GEAR LOCKER
1-43-1-C
WET LAB DRY LAB
1-34-1-C
DN
DN
1-46-4-Q
WORKSHOP
ENGRG OFF
1-43-2-Q
FLUSH HATCH
48x48
1-35-2-C
COMPUTER CTR
HPU
AFT CRANE
PASSAGE
1-61-1
DN
MOON POOL
"J" FRAME
DBL BERTH
DBL BERTH
DBL BERTH
DBL BERTH
DBL BERTH
DBL BERTH
SCALE: 3/16" = 1'-0"
1' 2'
6'4' 16'8' 12'
DOUBLE BITT (P/S)
PANAMA CANAL CHOCK (P/S)
PANAMA
CANAL
CHOCK
(P/S)
TIE-DOWN (TYP.)
STORES
AFFF TANK
SH
SH SH
WC
WC
LKR
LKR
D E S K
D E S K
D E S
KD
E S K
L K R
L K R
LKR
L K R
DESK
DESK
1-20-1-A
SAFE
D E S K
SH
ELV
ES
F.S. #6
F.S. #7
1-46-2-E
NOAA DRAWING NUMBER REV
CAD FILENAME SHT OFSCALE:
SIZE CAGE CODE
AA
B
C
D D
B
C
NF-085-001 C
NF085001-6C 6 73/16"=1'
D OYLJ5
"A" FRAME
W O R K
B E N C H
CABINETS
SCUBA
BOTTLE
RACK
COUNTER D
E S K
LKR ICE
MACHINE
FLASH
FREEZER
CHEST
FREEZER
EQMT
RACK
COUNTER
C O U N T E R
COUNTER
EQMT
RACK
EQMT RACK
DESK FC FC
D E S K
SODA
MACH
90 85 80 75 70 6065 55 50 45 40 35 30 25
15 10 5 0
W
D
W
D
PLAN VIEW, FOC'SLE DECK
SCALE: 3/16" = 1'-0"
01-24-1-L
ENG SR (2)
HEAD
01-25-1-L
SR (4)
01-32-2-L
PASSAGE
01-29-2-L
01-29-4-L
HEAD
CME SR
01-24-2-L
SR (2)
01-19-3-L
FAN ROOM
01-19-1-Q
01-12-1-L
SR (2)
02 LVL OVER
1-22-4-L
STAIR PASSAGE
01-18-0-L
WR/WC
01-19-2-L
SR (2)
01-12-2-L
LC
01-12-0-L
SR (2)
VESSEL
UP
DN
01-29-1-K
HALON STOR01-33-1-K
PAINT LKR BOSUN LKR &
EMERGENCY GEN LKR
01-36-1-E
SCALE: 3/16" = 1'-0"
PLAN VIEW, 02 DECK
DAVIT CONTROL STAND
RESCUE BOAT
DN
02-25-1-L
JO SR (2)
02-22-1-L
JO SR (2)
C.O. SR
02-15-0-L
HEAD
02-19-1-L
F.S. #1
UP
02-22-2-L
PASSAGE
DN
02-24-2-L
HEAD
UP
02-15-2-L
XO SR
VESSELCL
BRIDGE DECK (OVER)
02-22-4-L
HEAD
UP
SCALE: 3/16" = 1'-0"
PLAN VIEW, BRIDGE DECK
BRIDGEWING CONSOLE (P/S)
DN
DN
UPS SHIP SERVICE
PNL EP101/102
UPS COMMS
PNL EP105
NAV LTG PNL
INMARSAT-B
& GMDSS
FIRE & SMOKE DET.
PNL
AFT PROP./STEERING
CONSOLE
CHART TABLE
PH LTG PNL LP-104
DRINKING FOUNTAIN
S-BAND RADAR
ECDIS/VOYAGE PLANNING
OMNI THRUSTER MN. ELECT. UNIT
AUTONAV DP SCREEN
AUTONAV CONTROL SCREEN
OMNI THRUSTER JUNCTION BOX
X-BAND RADAR
GYRO ALARM UNIT
CHART TABLE
(DPS SYSTEM UNDER)
DEPTH RECORDER
WT DOOR INDICATOR PNL
GYROS
GYRO REPEATER (P/S)
VESSELCL
01-40-2-Q
DC LKR
CONTROL STAND
J-FRAME & A FRAME
DBL BERTH
DBL BERTH
SGL BERTH
DBL BERTH
DBL BERTH
SGL BERTH
SGL BERTH
DBL BERTH DBL BERTH
F.S. #2
EMERG. DIESEL
GEN. EXHAUST
DN
MACH'Y
MONITOR
SCALE: 3/16" = 1'-0"
1' 2'
6'4' 16'8' 12'
F.S. #3
RESCUE BOAT
(2) 25-MAN LIFERAFTS
(3) 25-MAN LIFERAFTS
DN
RESCUE BOAT DAVIT
UP
48" SQ. FLUSH HATCH
L K R
L K R
DESK
D E S K
L K R
L K R
DESK DESK
D E S K
D E S K
D E S K
DE
SK
L K R
L K R
DBL BE
RTH
D E S K
LKR
L K R
LKR
LKR
D E S K
DESK
F C
F C
D E S K
LKR
LKR
LKR
LKR
SGL BERTH
WC
WC
SH
SH
WC
SH
SH
WC
WC
WC
SHSH
L K R
D E S K
FC
BU
D E S K
D E S K
D E S K D E S K
LKR
LKR
LKR
LKR
BU
FC
D E S K
FC
SH
WC
S H E L V E S
F.S. #5
ANCHOR
WINDLASS
UP
VL
GRATING
AFFF STATION DOUBLE BITT (P/S)
SINGLE BITT (P/S)
150 GAL
GASOLINE
FWD
FWD
FWD
03-16-0-C
VESSELCL
SCALE: 3/16" = 1'-0"
PLAN VIEW, PILOT HOUSE TOP FWD
NOAA DRAWING NUMBER REV
CAD FILENAME SHT OFSCALE:
SIZE CAGE CODE
AA
B
C
D D
B
C
NF-085-001 C
NF085001-7A 7 73/16"=1'
D OYLJ5
INMARSAT
SEARCHLIGHT (P/S)
RADAR (P/S)
VL
VL
FLOODLIGHT
MAIN MAST
ECDIS/VOYAGE PLANNING
SH
02-29-2-L
HEAD
WC
02-34-1-L
JO SR (2)
02-29-1-L
JO SR (2)
02-32-2-L
JO SR (2)
DBL BERTH DBL BERTH
LKR LKR
LKR LKR
DBL BERTH
CAB.
LKR LKR
(1) 25-MAN LIFERAFT
COM 15
WINCH
BOOM REST
TELESCOPING BOOM
WT HATCH
JETTISONABLE
ENG SR
01-36-2-L
SGL BERTH
LKR
DESKD
E S K
A/C UNIT
60 55 4550 40 3035 025 20 15 10 5
STOWAGE UNDER
SEAT
40 35 30 25 20 15 10
M
IS
C
EQ
PT
P A N
EL
S/ M O U N
TI
N G
S W
30 25 20 15
15202530
| Layout1 |
| NF085001-2B.pdf |
| Layout1 |
| NF085001-3C.pdf |
| Outboard Profile |
| NF085001-4C.pdf |
| INBOARD PROFILE |
| NF085001-5C.pdf |
| all |
| NF085001-6C.pdf |
| all |
| NF085001-7C.pdf |
| all |
File details come from the government source that posted it.