BPM007579 Exhibit 6 Project Drawings.pdf
PDF 17 MB Posted
- Attached to
- ADOT Flagstaff Service Center Re-Roof
- Solicitation number
- BPM007579
- Issued by
- Cochise County, Arizona
About this file
Summary: ADOT Building Re-Roof Project
This construction document package represents a comprehensive set of specifications and drawings prepared by DLR Group for the Arizona Department of Transportation (ADOT) for a building re-roofing project located at 1959 S. Woodlands Village Boulevard, Flagstaff, Arizona. The project involves the complete removal and replacement of the existing roofing membrane, built-up roof, and insulation down to the metal deck, along with the installation of a permanent roof access system at the Motor Vehicle Division facility. The scope encompasses new roof system installation with an R-30ci insulation requirement per IECC standards, mechanical equipment relocation, structural modifications including an interior stair to the roof with a cold-formed metal-framed penthouse, and the infilling of an existing mechanical well. The project requires compliance with the 2018 International Building Code, 2018 International Mechanical Code, and various NFPA standards. Project management is under Omar Navarro (928-699-6279, onavarro@azdot.gov), with Michael Clark serving as project manager for DLR Group. The construction documents, approved as of September 3, 2025, expire September 30, 2027.
The project is structured as a single prime contract on a competitive bid, fixed-price basis, requiring contractor compliance with AISC and AWS standards for structural steel fabrication and installation. Key technical specifications include wind design requirements with an ultimate design wind speed of 115 mph, seismic design category C, and provisions for both EPDM and TPO roofing systems. The contractor is responsible for obtaining all necessary permits, coordinating with ADOT during the construction period when the facility remains occupied, maintaining life safety systems without interruption, and performing extensive coordination with mechanical, electrical, and plumbing trades. The project warranty period is one year minimum from Substantial Completion. No specific contract value, funding source, or award date is indicated in the construction documents provided.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADOT FLAGSTAFF OFFICE
BUILDING RE-ROOF
1959 S. WOODLANDS VILLAGE BLVD
FLAGSTAFF, AZ 86001
CONSTRUCTION DOCUMENTS
REV 1: 01/29/2026
OWNER INFORMATION:
OWNER: ARIZONA DEPARTMENT OF TRANSPORTATION
MANAGER: OMAR NAVARRO
PHONE: 928-699-6279
EMAIL: ONAVARRO@AZDOT.GOV
ADDRESS: 1655 W. JACKSON ST, MD 123F
FLAGSTAFF, AZ 86001
PROJECT ADDRESS:
1959 S WOODLANDS VILLAGE BLVD
FLAGSTAFF, AZ 86001
PARCEL#: 112-28-010-A
8.15 ACRES
SUBDIVISION: WOODLANDS VILLAGE UNIT 03 LOT 53
SUBDIVISION: WOODLANDS VILLAGE UNIT 01 LOT 14,
SIXTEENTH: SE QUARTER: SE SECTION: 20
TOWNSHIP: 21N RANGE: 07E
PROJECT TEAM:
DLR GROUP
ADDRESS: 6225 NORTH 24 STREET SUITE 250, PHOENIX, AZ 85016
OFFICE: 602.381.8580
FAX: 602.956.8358
CONTACT: PRIMARY POINT OF CONTACT = MICHAEL CLARK
ARCHITECTURE:
LARRY SMITH PRINCIPAL IN CHARGE
LSMITH@DLRGROUP.COM
MICHAEL CLARK PROJECT MANAGER
MICHAEL.CLARK@DLRGROUP.COM 720-257-5621 (DIRECT)
FRED IBARRA
FIBARRA@DLRGROUP.COM
ELECTRICAL:
CHRIS MAROTTA
CMAROTTA@DLRGROUP.COM
MECHANICAL:
DAVID ANDERSON
DANDERSON@DLRGROUP.COM
STRUCTURAL:
MARK FORMAN
MFORMAN@DLRGROUP.COM
ROOFING CONSULTANT:
BRYAN HILL
BRYAN@WRECORP.COM
APPLICABLE BUILDING CODES
PROJECT SCOPE DESCRIPTION
ADOT INTENDS TO REMOVE THE ENTIRE ROOFING MEMBRANE, BUILT UP ROOF, INSULATION (DOWN
TO METAL DECK), EQUIPMENT CURBS, PENETRATIONS, SLOPES, ETC., FOR A COMPLETELY
RENOVATED AND FUNCTIONAL ROOFING SYSTEM FOR THE MVD FACILITY. ADD A PERMANENT ROOF
ACCESS SYSTEM.
• 2018 INTERNATIONAL BUILDING CODE (IBC)
• 2018 INTERNATIONAL MECHANICAL CODE (IMC)
• 2018 INTERNATIONAL PLUMBING CODE (IPC)
• 2018 NATIONAL ELECTRIC CODE (NEC)
• 2018 INTERNATIONAL FIRE CODE (IFC)
• 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
• 2018 INTERNATIONAL FUEL GAS CODE (IFGC)
• 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
• ARIZONA ADMINISTRATIVE CODE TITLE 20, CHAPTER 5, ARTICLE 5
• 2010 ADA STANDARDS AS ADOPTED BY STATE OF ARIZONA
• ICC / ANSI A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
• UL STANDARDS
• ARIZONA DEPARTMENT OF ENVIRONMENTAL QUALITY (ADEQ) AIR STANDARDS AND GRAHAM
COUNTY AIR QUALITY DEPARTMENT OF AIR QUALITY STANDARDS
• SMACNA GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS
• SMACNA STANDARDS
• SMACNA, HVAC DUCT CONSTRUCTION STANDARDS
• NATIONAL FIRE PROTECTION ASSOCIATIONS (NFPA) STANDARDS (REFER TO BELOW LIST)
• REFER TO CHAPTER 35 FOR NFPA STANDARDS REQUIREMENTS:
1. NFPA 13 AUTOMATIC SPRINKLER SYSTEMS
2. NFPA 14 STANDPIPE SYSTEMS
3. NFPA 72 NATIONAL FIRE ALARM CODE
4. NFPA 80 FIRE DOORS AND OTHER OPENING PROTECTIVES
5. NFPA 101 LIFE SAFETY CODE
6. NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS
7. NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS
• APPLICABLE FEDERAL REGULATIONS:
- FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)
- U.S. ENVIRONMENTAL PROTECTION AGENCY REGULATIONS (EPA)
- AMERICANS WITH DISABILITIES ACT (ADA)
EXISTING BUILDING IS LISTED AS TYPE II-B CONSTRUCTION WITH OCCUPANCY TYPES A-3, B AND F-2
TABLE 601: ROOF CONSTRUCTIN AND ASSOCIATED SECONDARY MEMBERS = 0 HR RATING
WIND DESIGN DATA: ULTIMATE DESIGN WIND SPEED Vult =115 MPH
RISK CATEGORY II
EXPOSURE 'C'
INTERNAL PRESSURE COEFF. = +/- 0.18
COMPONENT AND CLADDING DESIGN: 30 PSF
SEISMIC DESIGN DATA:
IMPORTANCE FACTOR = 1.0
RISK CATEGORY II
SEISMIC DESIGN CATEGORY 'C'
SITE CLASS 'D'
2018 INTERNATIONAL EXISTING BUILDING CODE:
SECTION 602 ALTERATION - LEVEL 1:
• LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF
EXISTING MATERIALS, ELEMENT, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT OR FIXTURES THAT SERVE THE SAME PURPOSE.
CODE ANALYSIS:
ENERGY CODE DATA VALUES ROOF R-1
MATERIAL: DEPTH R-VALUE
OUTSIDE AIR FILM 0.00" 0.25
EPDM ROOFING MEMBRANE 0.06" 0.00
COVER BOARD 0.50" 0.56
RIGID INSULATION (POLYISO) 6.00" 34.8
(E) METAL DECK 1.50" 0.00
INSIDE AIR FILM 0.00" 0.68
TOTAL: 8.06" 36.3
SOLAR REFLECTANCE INDEX: 9
IECC CLIMATE ZONE: 5B COCONINO
ROOF - INSULATION ENTIRELY ABOVE DECK R-30ci
ASHRAE 90.1-2019 R-30ci
METAL FRAMED WALLS R-20 + R-9ci
D
L R
G ro u p
REVISIONS
A B C D E F
/2
/2
:3
:3
P M
A u to d e s k D o c s
/3
-2
-0
A
D O
T M
V D
R e ro o f N
/3
-2
-0
A
D O
T M
V D
R e ro o f_ A
R
.r v t
30-25134-00
09/03/2025
A D
O T
B U
IL
D
IN
G
R E
-R O
O F
P R
O J E
C T
CONSTRUCTION
DOCUMENTS
COVER SHEET
G0.1
S
W o o d la n d s V ill a g e B lv d
F la g s ta ff A
Z
ARCHITECTURAL
AS1.1 ARCHITECTURAL SITE PLAN
AD1.1A DEMO FLOOR PLAN - LEVEL 1
AD1.2 DEMO FLOOR PLAN - LEVEL 2
AD1.4 DEMO ROOF PLAN
AD3.1 REFLECTED CEILING DEMOLITION PLAN - LEVEL 1 & 2
A1.1 OVERALL FLOOR PLAN, LEVEL 1
A1.2A OVERALL FLOOR PLAN - LEVEL 2
A1.3 OVERALL ROOF PLAN
A3.1 OVERALL - REFLECTED CEILING PLAN - LEVEL 1
A3.2 OVERALL - REFLECTED CEILING PLAN - LEVEL 2
A5.1 WALL SECTIONS AND DETAILS
A5.2 3D SECTIONS
A9.1 ELEVATIONS & ROOF-FRAMING DETAILS
A9.3 STAIRS AND HANDRAIL DETAILS
GENERAL
G0.1 COVER SHEET
G1.1 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
STRUCTURAL
S0.1 GENERAL STRUCTURAL NOTES
S0.2 GENERAL STRUCTURAL NOTES & SPECIAL INSPECTIONS
S0.3 GENERAL STRUCTURAL NOTES, SYMBOLS & ABBREVIATIONS
S2.2 OVERALL ROOF FRAMING PLAN
S3.1 STRUCTURAL DETAILS
MECHANICAL
MD1.1 LEVEL 01 - HVAC DEMOLITION PLAN
MD1.3 LEVEL 03 - HVAC DEMOLITION PLAN
M1.1 LEVEL 01 - HVAC PLAN
M1.3 LEVEL 03 - ROOF MECHANICAL PLAN
M8.1 PLUMBING & MECHANICAL SCHEDULES, DETAILS & SECTIONS
ELECTRICAL
E0.1 ELECTRICAL SYMBOLS
ED1.3 LEVEL 03 - ELECTRICAL DEMOLITION PLAN
E1.3 LEVEL 03 - LIGHTING PLAN
E2.3 LEVEL 03 - POWER PLAN
E5.1 ELECTRICAL DIAGRAMS
CITY OF FLAGSTAFF STAMPINGINDEX OF DRAWINGSSITE CONTEXT AERIAL
VICINITY MAP
PROJECT INFORMATION NOT TO SCALE IMAGE FROM GOOGLE EARTH
NOT TO SCALE IMAGE FROM BING MAPS
NORTH
N O R T H
CODE DATA SUMMARY
1 01/29/2026
EXPIRES: 09/30/2027
01/29/2026
RembertoMartinez SAFEbuilt - Conditionally Approved
202012 Approved PCS
GENERAL SYMBOLS
SIM
ROOM NAME
XXX-XX
DETAIL NUMBER
SHEET NUMBER
CROSS REFERENCE
WALL SECTION
SIMILAR OR TYPICAL
REFERENCE
DETAIL REFERENCE
BUILDING SECTION
SHEET NOTE
COLUMN GRID LINE
ROOM NUMBER/NAME
REVISION NUMBER
EARTH
GRAVEL
SAND
CONCRETE
PRECAST CONCRETE
STEEL
STONE
CONCRETE MASONRY UNIT
BRICK VENEER
LEVEL XX
XXX'-XX"
LEVEL ELEVATION
GYM FLOOR
WOOD
(CONTINUOUS BLOCKING)
WOOD
(NON-CONTINUOUS BLOCKING)
WOOD (TRIM/FINISH)
GLASS
SHINGLES
PLYWOOD (LARGE SCALE)
GYPSUM WALL BOARD
BLANKET INSULATION
RIGID INSULATION
SPRAY FOAM INSULATION
MINERAL WOOL INSULATION
PROTECTION BOARD
CARPET (LARGE SCALE)
ACOUSTIC TILE (LARGE SCALE)
TILE (LARGE SCALE)
REFERENCE KEYNOTE
XX A4.XX BUILDING ELEVATION
A12.X
XX
XX XX
XX
INTERIOR ELEVATION
100'-0"
TYP FF EL=
100'-0"
FINISH FLOOR
ELEVATION
SPOT ELEVATION
X
GENERAL NOTES
A. GENERAL NOTES APPLY TO ALL SHEETS.
B. DIMENSIONS ARE ACTUAL AND ARE TO FACE OF STUDS, FACE
OF CONCRETE WALLS, FACE OF CMU WALLS, FACE OF FRAMES,
OR CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE.
C. COORDINATE ALL MECHANICAL CHASE SIZES WITH THE
MECHANICAL CONTRACTOR.
D. ARCHITECTURAL FINISH FLOOR ELEVATION 0'-0" EQUALS
ACTUAL SITE REFERENCE ELEVATION OF FINISH FLOOR ?????
FEET.
E. ALL PENETRATIONS THROUGH WALLS SHALL BE SEALED WITH
PENETRATION FIRE STOPPING MATERIAL AS REQUIRED TO
ACHIEVE THE RESPECTIVE FIRE-RESISTANCE RATING AND
SMOKE STOPPAGE. SEE SPECIFICATION SECTION 078413.
F. COORDINATE WITH MECHANICAL AND ELECTRICAL
CONTRACTORS THE SIZE AND LOCATION OF EQUIPMENT PADS
SHOWN ON PLANS.
G. FIRE-RESISTANCE-RATED ENCLOSURES AROUND ALL STEEL
COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO UNDERSIDE
OF FLOOR OR ROOF DECK ABOVE FOR EACH LEVEL.
H. CONSTRUCTION DOCUMENTS ARE COMPLEMENTARY. SEE
DRAWING FOR QUANTITIES AND LOCATION OF WORK. SEE
SPECIFICATIONS FOR QUALITIES AND CONDITIONS OF WORK.
I. WORK: ALL ASPECTS OF THE WORK AND ITEMS NOT
SPECIFICALLY MENTIONED, BUT NECESSARY TO MAKE A
COMPLETE WORKING INSTALLATION, SHALL BE INCLUDED AND
INDICATED IN THE CONTRACTOR'S BID.
J. SHEET NOTES ONLY APPLY TO PARTICULAR DRAWING OR
SERIES OF DRAWINGS.
K. NO ASBESTOS OR PCB CONTAINING MATERIALS SHALL BE USED
ON THIS PROJECT.
L. DO NOT SCALE DRAWINGS. DIMENSIONS NOTED PREVAIL.
NOTIFY ARCHITECT IN CASE OF DISCREPANCY.
M. HORIZONTAL AND VERTICAL DIMENSIONS ARE MINIMUM
DIMENSIONS. CLEARANCES ARE GIVEN TO FINISH SURFACES.
GC TO VERIFY ALL CLEARANCES. NOTIFY ARCHITECT IN CASE
OF DISCREPANCY.
ARCHITECTURAL SYMBOLS
XX/ A11.X
XX. X. XX
CASEWORK ELEVATION
DOOR NUMBER
EXTERIOR WINDOW /
CURTAIN WALL NUMBER
WALL TYPE
A110
A124
XX/ A11.X XXXX
XX
XX
APC-1
9' - 0"
CEILING TYPE
CEILING HEIGHT
CEILING TYPE
INTERIOR WINDOW
NUMBER
D
L R
G ro u p
REVISIONS
A B C D E F
/4
/2
:2
:3
P M
A u to d e s k D o c s
/3
-2
-0
A
D O
T R e ro o f N
/3
-2
-0
A
D O
T R e ro o f_
A R
.r v t
30-25134-00
09/03/2025
A D
O T
B U
IL
D
IN
G
R E
-R O
O F
P R
O J E
C T
CONSTRUCTION
DOCUMENTS
GENERAL NOTES,
SYMBOLS AND
ABBREVIATIONS
G1.1
S
W o o d la n d s V ill a g e B lv d
F la g s ta ff A
Z
GENERAL ABBREVIATIONS
# NUMBER
& AND
@ AT
ADA AMERICANS WITH DISABILITY ACT
ADDN ADDITION OR ADDITIONAL
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
ALT ALTERNATE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
BLDG BUILDING
BSMT BASEMENT
CL CENTER LINE
CLG CEILING
CM CENTIMETER
CONC CONCRETE
CONN(S) CONNECTION(S)
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACT(OR)
CTR CENTER
D DEPTH
DEG DEGREE
DEMO DEMOLISH OR DEMOLITION
DIA DIAMETER
DIM DIMENSION
DIV SPECIFICATION DIVISION
DN DOWN
DTL DETAIL
DWG(S) DRAWING(S)
E EAST
EA EACH
EC ELECTRICAL CONTRACTOR
EL ELEVATION
ELEC ELECTRICAL
ENG ENGINEER
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
EXST EXISTING
EXT EXTERIOR
FIN FINISHED
FL FLOOR
FT FEET
FUT FUTURE
GC GENERAL CONTRACTOR
GOVT GOVERNMENT
H HEIGHT
HORIZ HORIZONTAL
HT HEIGHT
i.e. THAT IS
IBC INTERNATIONAL BUILDING CODE
IN INCH
INT INTERIOR
LB(S) POUND(S)
M METER
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MM MILLIMETER
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
OVHD OVERHEAD
PAR PARALLEL
PENT PENTHOUSE
PLYWD PLYWOOD
QTY QUANTITY
REQ(D) REQUIRE(D)
REV REVISION(S)
RM ROOM
RND ROUND
S SOUTH
SCHED SCHEDULE
SECT SECTION
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION(S)
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SYM SYMETRICAL
TEMP TEMPORARY
TYP TYPICAL
UNEX UNEXCAVATED
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
W WEST
W/ WITH
W/O WITHOUT
A/E ARCHITECT/ENGINEER
AB AIR BARRIER
ABS ASBESTOS
ACC ADA ACCESSIBLE
ACR ACRYLIC
ACT ACOUSTIC CEILING TILE
AD ACCESS DOOR
ADJ ADJUSTABLE
ADJT ADJACENT
ADMIN ADMINISTRATION
AEC AUTOMATED EXTERNAL DEFIBRILLATORS
AL ALUMINUM
ALUM ALUMINUM
AP ACCESS PANEL
APC ACOUSTIC PANEL CEILING
ASPH ASPHALT
AUTO AUTOMATIC
AVG AVERAGE
AWP ACOUSTIC WALL PANEL
B.O. BOTTOM OF
BCS BABY CHANGING STATION
BD BOARD
BLK BLOCK
BLKG BLOCKING
BLKHD BULKHEAD
BM(S) BEAM(S)
BOT BOTTOM
BRDG BRIDGING
BRG BEARING
BRKT BRACKET
BT BATHTUB
BTWN BETWEEN
CAB CABINET
CBD CHALKBOARD
CER CERAMIC
CF CUBIC FEET
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFMF COLD-FORMED METAL FRAMING
CG CLEAR FLOAT GLASS
CGD CORNER GUARD
CI CAST IRON
CIG CLEAR INSULATING GLASS
CIP CAST IN PLACE
CJ CONTROL JOINT
CJA CONTROL JOINT ABOVE
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
COM COMMON
COMB COMBINATION
COMM COMMUNICATIONS
COMPR COMPRESSIBLE
CONF CONFERENCE
CONFIG CONFIGURATION
CORR CORRIDOR
CP COVER PLATE
CPT CARPET
CR CHAIR RAIL
CS COUNTERSINK
CSTJ CONSTRUCTION JOINT
CSWK CASEWORK
CT CERAMIC TILE
CTG CLEAR TEMPERED FLOAT GLASS
CTIG CLEAR TEMPERED INSULATING GLASS
CU COPPER
CU COMBINATION UNIT
CV CONDOM VENDOR
CY CUBIC YARD
CYL CYLINDER
DB DECIBEL
DBL DOUBLE
DC DUST COLLECTOR
DEPR DEPRESS(ION)(ED)
DEPT DEPARTMENT
DET DETENTION
DF DRINKING FOUNTAIN
DG DOOR GRILLE
DIAG DIAGONAL
DPFG DAMPROOFING
DR DOOR
DSN DOWNSPOUT NOZZLE
DW DISHWASHER
DWL(S) DOWEL(S)
DWR DRAWER
EB EXPANSION BOLT
EE EACH END
EEW EMERGENCY EYE WASH
EEWS EMERGENCY EYE WASH SHOWER
EFF EFFICIENCY
EJ EXPANSION JOINT
ELAS ELASTOMERIC
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENTR ENTRANCE
ERF EPOXY RESIN FLOORING
EUI ENERGY USE INTENSITY
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXP EXPANSION
EXP EXPOSED
F FABRIC
F.O. FACE OF
FAB FABRICATE(D)
FB FACE BRICK
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIG FIGURE
FIX FIXTURE
FLASH FLASHING
FLEX FLEXIBLE
FLG FLOORING
FLM FULL LENGTH MIRROR
FLUOR FLUORESCENT
FO FINISH OPENING
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FP FIREPROOFING
FPG FIRE-PROTECTIVE GLASS
FR FIRE RESISTANT
FRG FIRE-RESISTIVE GLASS
FRP FIBERGLASS REINFORCED PANEL
FRT FIRE RESISTANCE TREATED
FS FLOOR SINK
FSS FOLDING SHOWER SEAT
FTG FOOTING
FVC FIRE VALVE CABINET
FWC FABRIC WALL COVERING
G GROUT
GA GAUGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
ARCHITECTURAL ABBREVIATIONS
GD GARBAGE DISPOSAL
GEN GENERAL
GFA GROSS FLOOR AREA
GL GLUE LAMINATED
GL GLASS
GMP GUARANTEED MAXIMUM PRICE
GR GUARD RAIL
GR GRADE
GRS GALVANIZED RIGID STEEL
GWB GYPSUM WALL BOARD
GYP GYPSUM
HC HOLLOW CORE
HD HAND DRYER
HDF HIGH DENSITY FIBERBOARD
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HR HOUR
HR HANDRAIL
HS HARDWARE SET
HSS HOLLOW STRUCTURAL SHAPE
HVAC HEATING VENTILATING AND AIR CONDITIONING
IAW IN ACCORDANCE WITH
ID INSIDE DIAMETER
IF INSIDE FACE
IIP INSULATED INFILL PANEL GLASS
IJ ISOLATION JOINT
IJS IN JOIST SPACE
INC INCLUDE(ING)
INSUL INSULATION
JAN JANITOR
JBE JOIST BEARING ELEVATION
JBX JUNCTION BOX
JCT JUNCTION
JFB JOINT FILLER BOARD
JST JOIST
JT JOINT
KCJ KEYED CONSTRUCTION JOINT
KD KNOCKDOWN
KH KITCHEN HOOD
KIT KITCHEN
L ANGLE
LAB LABORATORY
LAM LAMINATED
LAV LAVATORY
LBR LUMBER
LDG LOADING
LF LINEAR FOOT
LG LENGTH (LONG)
LG LAMINATED GLASS
LIN LINEAR
LINO LINOLEUM
LKR LOCKER
LOC LOCATION
LONG LONGITUDINAL
LSC LIFE SAFETY CODE
LTG LIGHTING
LV LOUVER
LVT LUXURY VINYL TILE
MAG MAGNETIC
MAINT MAINTENANCE
MAN MANUAL
MAS MASONRY
MATL MATERIAL
MB MOP BASIN
MBD MARKER BOARD
MBH MOP/BROOM HOLDER
MC MEDICINE CABINET
MEMB MEMBRANE
MH MANHOLE
MR/S MIRROR WITH SHELF
MTD MOUNTED
MTG MOUNTING
MUL MULLION
NC NOISE CRITERIA
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NOM NOMINAL
O to O OUT TO OUT
OA OVERALL
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFF OFFICE
OFOI OWNER FURNISHED OWNER INSTALLED
OH OPPOSITE HAND
OPG(S) OPENING(S)
OSHA OPERATIONAL SAFETY AND HEALTH ADMINISTRATION
OTB OPEN TO BELOW
OVFL OVERFLOW
P PAINT
PAN B PANIC BOLT
PB PARTICLE BOARD
PC PRECAST CONCRETE
PCD PAPER CUP DISPENSER
PCT PORCELAIN CERAMIC TILE
PD PANIC DEVICE
PERF PERFORATED
PERP PERPENDICULAR
PG PATTERN GLASS
PIC PORTABLE INSTRUMENT CONNECTION
PIG PATTERN INSULATING GLASS
PL PLATE
PL PROPERTY LINE
PL PLASTIC LAMINATE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PR PAIR
PREFAB PREFABRICATED
PROJ PROJECT(OR) (ION)
PS PROJECTION SCREEN
PT POINT
PT POINT OF TANGENCY
PTD PAPER TOWEL DISPENSER
PTD/R COMBINATION TOWEL DISPENSER/RECEPTACLE
PTN PARTITION
PVC POLYVINYL CHLORIDE
PWL SOUND POWER LEVEL
QGV QUAD GAS VALVE
QT QUARRY TILE
QTR RND QUARTER ROUND
R RISER
RAD RADIUS
RB RUBBER BASE
RC REMOTE CONTROL
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFERENCE
REFL REFLECTED
REM REMOVABLE
RESIL RESILIENT
RF RESILIENT FLOORING
RF RUBBER FLOOR
RFM RECESSED FLOOR MAT
RH ROBE HOOK
RI&C ROUGH IN AND CONNECT
S SINK
SAT SPRAYED ACOUSTIC TREATMENT
SAW SOUND ABSORBING WALL UNITS
SB SPLASH BLOCK
SC SOLID CORE
SC SHOWER CURTAIN
SCD SEAT COVER DISPENSER
SCH SHOWER CURTAIN HOOK
SCR SHOWER CURTAIN ROD
SCT STRUCTURAL CLAY TILE
SD SOAP DISPENSER
SECY SECRETARY
SF SQUARE FEET
SG SPANDREL GLASS
SG SPECIALTY GLASS
SGL SINGLE
SGV SINGLE GAS VALVE
SH SHOWER
SHM SECURITY HOLLOW METAL
SLNT SEALANT
SM SHEET METAL
SND SANITARY NAPKIN DISPOSAL
SNV SANITARY NAPKIN VENDOR
SO SENSOR OPERATED
SPL SOUND PRESSURE LEVEL
SQ SQUARE
SR SURFACE MOUNTED ELECTRICAL RACEWAY
SS SOLID SURFACE
SSA STORM SHELTER AREA
SSM SOLID SURFACE
SSS STAINLESS STEEL SHELF
SST STAINLESS STEEL
ST STONE
ST STAIR
STAG'D STAGGERED
STC SOUND TRANSMISSION CLASS
STGR STRINGER
SUBFL SUBFLOOR
SUL SULPHUR
SURF SURFACE
SUSP SUSPENDED
SVF SHEET VINYL FLOORING
SVF SERVICE FIXTURE
SVG SERVICE FIXTURE GROUP
T TREAD
T&G TONGUE AND GROOVE
T.O. TOP OF
TAN TANGENT
TB TOWEL BAR
TBD TACK BOARD
TCP TOILET COMPARTMENT PARTITION
TERR TERRAZZO
TFG TINTED FLOAT GLASS
TG TEMPERED GLASS
TH THRESHOLD
THK THICK(NESS)
TI TENANT IMPROVEMENT
TIG TINTED INSULATING GLASS
TMR TILT MIRROR UNIT
TOIL TOILET
TOP TOP OF PAVING
TRANS TRANSVERSE
TT TERRAZZO TILE
TTD TOILET TISSUE DISPENSER
TTG TINTED TEMPERED FLOAT GLASS
TTIG TINTED TEMPERED INSULATING GLASS
TW TACK WALL
UL UNDERWRITERS LABORATORIES
UR URINAL
US UTILITY SHELF
UTIL UTILITY
VB VAPOR BARRIER
VB VINYL BASE
VCB VENTED COVE BASE
VF VINYL FLOOR
VOC VOLITILE ORGANIC COMPOUND
VOL VOLUME
VP VENEER PLASTER
VT VINYL TILE
VWC VINYL WALL COVERING
W WIDE
WB WALL BASE
WC WATER CLOSET
WC WALL COVERING
WCL WATER CLOSET/LAVATORY COMBINATION
WD WOOD
WDF WOOD FLOORING
WDW WINDOW
WG POLISHED WIRE GLASS
WI WROUGHT IRON
WOM WALK OFF MAT
WR WASTE RECEPTACLE
WRB WEATHER RESISTANT BARRIER
WW WARM WHITE
WWF WELDED WIRE FABRIC
YD YARD
09/03/2025
EXPIRES 09/30/2027
RembertoMartinez SAFEbuilt - Conditionally Approved
STRUCTURAL RENOVATION SCOPE
1. PROJECT STRUCTURAL SCOPE IS LIMITED TO THE FOLLOWING:
a. INTERIOR STAIR FROM MEZZANINE TO ROOF WITH COLD-FORMED METAL FRAMED PENTHOUSE.
b. MECHANICAL UNIT RE-LOCATION, AND INFILL OF ROOF TOP MECHANICAL WELL.
EXISTING CONDITIONS
1. CONTRACTOR IS TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. ALL WORK AND MATERIALS NECESSARY TO INSTALL NEW WORK IN EXISTING BUILDING(S) SHALL BE INCLUDED.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AND SHALL CONTACT
THE ENGINEER IF ANY DISCREPANCIES ARE FOUND BEFORE PROCEEDING. NOTIFY ENGINEER
IMMEDIATELY IF EXISTING CONDITIONS DO NOT MATCH, OR SEEM IN CONFLICT WITH, INFORMATION
SHOWN ON DRAWINGS.
3. DIMENSIONS INDICATED ON PLAN AS FIELD VERIFY, OR “FV”, ARE DIMENSIONS THAT MAY BE REQUIRED FOR FABRICATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF
DIMENSIONS IN THE FIELD NECESSARY FOR FABRICATION OF MEMBERS AND PRIOR TO
SUBMISSION OF SHOP DRAWINGS.
4. CONTRACTOR TO PROVIDE PROTECTION FOR ALL EXISTING BUILDING MATERIALS AND EQUIPMENT
TO REMAIN FROM DAMAGE DUE TO DEMOLITION OR CONSTRUCTION OPERATIONS PERFORMED
UNDER THIS CONTRACT.
5. THE SEQUENCE OF CONSTRUCTION SHALL BE THE RESPONSIBILITY THE CONTRACTOR. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL TEMPORARY GUYS, BRACING, AND
OTHER SUPPORTS AS NEEDED TO SAFELY RESIST ALL GRAVITY AND LATERAL LOADS TO WHICH
THE EXISTING OR PROPOSED STRUCTURE MAY BE SUBJECTED, INCLUDING LOADS FROM
ERECTION EQUIPMENT AND ERECTION OPERATIONS, AND WIND OR SEISMIC FORCES COMPARABLE
IN INTENSITY FOR WHICH THE STRUCTURE IS DESIGNED. LOAD VERIFICATION OF EXISTING
MEMBERS TO RECEIVE TEMPORARY SHORING SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR’S ENGINEER.
6. ALL ERECTION AND CONSTRUCTION PROCEDURES SHALL MEET THE REQUIREMENTS OF ALL
APPLICABLE CODES AND ORDINANCES.
7. ALL FRAMING CONNECTIONS TO EXISTING STRUCTURE SHALL BE FIELD VERIFIED PRIOR TO SHOP DRAWING PRODUCTION AND FABRICATION. FIELD VERIFIED DIMENSIONS SHALL BE INCLUDED ON
FIRST SHOP DRAWING SUBMITTAL AND NOTED AS SUCH.
8. EXISTING UTILITY LINES SHALL BE PROBED PRIOR TO CONSTRUCTION OF FOUNDATIONS. NOTIFY
ENGINEER IF THE TOP OF ANY UTILITY PIPE COMES WITHIN 3'-0" OF THE BOTTOM OF ANY
FOUNDATION. DETERMINE THE LOCATION OF ALL NEW AND EXISTING UNDERGROUND UTILITIES IN
AND ADJACENT TO THE AREA OF WORK PRIOR TO EXCAVATION. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR ANY DAMAGES WHICH MAY RESULT FROM FAILURE TO EXACTLY LOCATE,
PROTECT, AND PRESERVE ALL EXISTING UNDERGROUND UTILITIES.
9. EXCAVATION UNDER OR NEAR IN-PLACE FOOTINGS WHICH DISTURBS THE COMPACTED SOIL
BENEATH THE FOOTINGS IS NOT PERMITTED.
10. CONTRACTOR SHALL LOCATE REBAR IN EXIST. CONSTRUCTION PRIOR TO DRILLING OF HOLES AND SHALL TAKE CARE NOT TO DAMAGE EXIST. BARS. IF DAMAGE TO EXIST. REBAR OCCURS DURING
CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING THE DAMAGE. REPAIR
PROCEDURES NOT DETAILED IN THE CONTRACT DOCUMENTS WILL REQUIRE PREPARATION BY A
QUALIFIED PROFESSIONAL ENGINEER REGISTERED IN THE STATE IN WHICH THE PROJECT IS
LOCATED AND MUST BE APPROVED BY THE ENGINEER.
DEMOLITION
1. DEMOLITION OF EXISTING STRUCTURE TO BE REMOVED SHALL BE PERFORMED BY THE
CONTRACTOR USING MEANS NECESSARY TO PREVENT DAMAGE TO THE EXISTING STRUCTURE TO
REMAIN. DAMAGE TO THE EXISTING STRUCTURE TO REMAIN SHALL BE REPAIRED AT THE
CONTRACTOR'S EXPENSE USING METHODS REVIEWED BY THE STRUCTURAL ENGINEER. IF
EXISTING CONDITIONS DIFFER FROM THOSE SHOWN IN THE CONTRACT DOCUMENTS CONTACT
THE ARCHITECT PRIOR TO PROCEEDING WITH WORK.
2. SHORING OF THE EXISTING STRUCTURE SHALL BE PROVIDED BY THE CONTRACTOR AND
DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER REGISTERED IN THE STATE IN WHICH THE
PROJECT IS LOCATED.
GENERAL
1. THE DRAWINGS REPRESENT THE FINISHED STRUCTURE, NOT THE METHOD OF CONSTRUCTION. THE
CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND
HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS
HAVE BEEN COMPLETED. THE RESEARCH, DESIGN, SAFETY, ADEQUACY, AND INSPECTION OF
ERECTION BRACING, SHORING, GUYING, TEMPORARY SUPPORTS, ETC, IS THE RESPONSIBILITY OF
THE CONTRACTOR.
2. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS AND METHODS,
SEQUENCES OF CONSTRUCTION, OR CONSTRUCTION TECHNIQUES USED TO PERFORM THE WORK.
OBSERVATION VISITS TO THE SITE WILL NOT INVOLVE REVIEW OF THESE ITEMS.
3. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PROGRAM. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND
REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT ADVISE ON, NOR ISSUE DIRECTION, AS TO SAFETY PRECAUTIONS AND PROGRAMS. OBSERVATION VISITS TO THE SITE WILL NOT INVOLVE
REVIEW OF THESE ITEMS.
4. CONTRACTOR IS TO ESTABLISH AND VERIFY OPENINGS AND INSERTS FOR ITEMS TO BE INSTALLED
BY OTHER TRADES PRIOR TO SUBMITTAL OF SHOP DRAWINGS AND CONSTRUCTION.
5. CONSTRUCTION MATERIAL AND EQUIPMENT LOADS PLACED ON THE STRUCTURE DURING THE
CONSTRUCTION PROCESS SHALL NOT EXCEED THE DESIGN LIVE LOAD OF THE STRUCTURE NOTED IN THESE DRAWINGS. THE ENGINEER SHALL NOT BE RESPONSIBLE TO INVESTIGATE, NOR APPROVE, THE STRUCTURE FOR CONSTRUCTION MATERIAL OR EQUIPMENT LOADING. ERECTION OR
CONSTRUCTION LOADS ARE NOT TO BE APPLIED UNTIL PROPER STRUCTURAL FRAMING
CONNECTIONS ARE MADE, AND ALL TEMPORARY BRACING IS IN PLACE. THE CONTRACTOR SHALL
DESIGN AND PROVIDE TEMPORARY BRACING OF THE STRUCTURE WHERE NECESSARY FOR
CONSTRUCTION LOADS.
6. DETAILS THAT ARE NOTED AS "TYPICAL" OR "TYP" ON DETAIL TITLES ARE TO BE APPLIED TO THE
PROJECT CONSTRUCTION AS GENERAL CONSTRUCTION METHODS UNLESS NOTED OTHERWISE.
THESE DETAILS ARE NOT CUT AT ALL LOCATIONS WHERE THEY OCCUR, AND THEY MAY NOT BE CUT AT ALL. WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR
CONDITIONS ELSEWHERE ON THE PROJECT, SUBJECT TO APPROVAL OF THE ENGINEER.
7. DO NOT SCALE DRAWINGS. CONTRACTOR IS TO VERIFY ALL DIMENSIONS RELATIVE TO
ARCHITECTURAL OR OTHER DISCIPLINE DRAWINGS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES
MUST BE REPORTED TO THE ENGINEER PRIOR TO CONSTRUCTION.
8. WHERE DISCREPANCIES OCCUR BETWEEN GENERAL NOTES, PLANS, DETAILS, AND SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN, UNLESS APPROVED OTHERWISE BY THE
ENGINEER IN WRITING PRIOR TO CONSTRUCTION.
9. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL OTHER
DISCIPLINES AND SPECIFICATIONS. THE CONTRACTOR SHALL ESTABLISH AND VERIFY THE
REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERT ANCHORS, HOLES, AND OTHER ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK. DO NOT PENETRATE ANY
STRUCTURAL ELEMENTS (BEAMS, COLUMNS, WALLS, SLABS, STEEL DECKS, ETC) WITHOUT PRIOR
WRITTEN APPROVAL OF THE ENGINEER.
10. IF THE ENGINEER'S SEAL AND SIGNATURE IS NOT AFFIXED TO THESE DRAWINGS, THESE DRAWINGS ARE INTENDED FOR PRELIMINARY PURPOSES ONLY AND SHALL NOT BE USED FOR CONSTRUCTION.
11. STRUCTURAL JOINT DIMENSIONS SHOWN ON PLANS AND DETAILS (EXPANSION, SEISMIC,
SEPARATION, ETC) INDICATE THE MINIMUM CLEAR DISTANCE REQUIRED. SEE ARCHITECTURAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS AND INFORMATION.
SUBMITTALS
1. THE FOLLOWING ITEMS ARE REQUIRED STRUCTURAL SUBMITTALS AS DESCRIBED IN THE
SPECIFICATIONS.
a. 031000 CONCRETE FORMING & ACCESSORIES
b. 032000 CONCRETE REINFORCING
c. 033000 CAST-IN-PLACE CONCRETE REINFORCING
d. 051200 STRUCTURAL STEEL FRAMING
e. 053100 STEEL DECKING
f. 054000 COLD-FORMED METAL FRAMING
COLD FORMED METAL FRAMING
1. FABRICATE, AND ERECT COLD-FORMED STEEL STRUCTURAL MEMBERS PER THE REQUIREMENTS OF
THE LATEST EDITION OF THE SPECIFICATION FOR THE DESIGN OF COLD-FORMED STRUCTURAL
MEMBERS BY THE AMERICAN IRON AND STEEL INSTITUTE, INCLUDING ALL APPLICABLE
AMENDMENTS. WHERE REQUIRED, THE SEISMIC DESIGN OF COLD-FORMED STRUCTURAL MEMBERS, AISI S100 & S200, AND SHALL BE IN ACCORDANCE WITH THE ADDITIONAL PROVISIONS OF THE
BUILDING CODE.
2. MINIMUM YIELD STRENGTH FOR 43 AND 33 MIL STUDS, JOISTS, STRAPS, BRIDGING, ETC, SHALL BE 33 KSI MINIMUM. YIELD STRENGTH FOR 97, 68, AND 54 MIL STUDS, JOISTS, STRAPS, BRIDGING, ETC, SHALL BE 50 KSI MINIMUM.
3. PROVIDE CFMF MEMBERS WITH SECTION PROPERTIES REQUIRED TO RESIST APPLIED LOADING AND
AS MANUFACTURED BY MEMBERS OF THE STEEL STUD MANUFACTURER'S ASSOCIATION (SSMA)
COMPLYING WITH ICC ESR-3064P AND THE BUILDING CODE.
4. STUDS IN LOAD BEARING WALLS SHALL ALIGN VERTICALLY WITH THE JOIST BEARING LOCATION
ABOVE AND BELOW. UNLESS NOTED OTHERWISE, PROVIDE DOUBLE STUDS AT ALL JAMBS,
CORNERS, INTERSECTIONS, BEAM BEARINGS, AND JOIST BEARINGS. PROVIDE ADDITIONAL STUDS AT JAMBS AS REQUIRED BY THE CFMF SUPPLIER. ALL STUDS SHALL BE SECURELY SEATED FOR FULL
END BEARING ON TOP AND BOTTOM TRACK.
5. TEMPORARY BRACING SHALL BE INSTALLED AND LEFT IN PLACE UNTIL OTHER MEANS IS PROVIDED
TO ADEQUATELY BRACE THE STRUCTURE. STUD SUPPLIER AND INSTALLER SHALL PROVIDE ALL
CONNECTORS, FASTENERS, BRIDGING AND BRACING AS REQUIRED TO PROVIDE A COMPLETE
STABLE INSTALLATION.
6. STUDS AND TRACKS ARE TO BE ATTACHED WITH SHEET METAL SCREWS (SMS) WITH SIZES CALLED OUT ON THE DETAILS. PENETRATION OF SCREWS THOROUGH JOINED MATERIAL SHALL NOT BE LESS THAN 3 EXPOSED THREADS. SCREWS ARE TO BE INSTALLED AND TIGHTENED IN ACCORDANCE WITH
SCREW MANUFACTURER’S RECOMMENDATIONS. SHEET METAL SCREWS SHALL COMPLY WITH ASTM
C1513, SELF-DRILLING AND TAPPING TYPE, WITH PANCAKE FRAMER HEAD TYPE FOR #10 SMS AND
HEX WASHER HEAD TYPE FOR #12 AND #14 (1/4ӯ) SMS UNLESS NOTED OTHERWISE.
7. AT A MINIMUM, PROVIDE BRIDGING AT 4'-0" OC MAX FOR FULL HEIGHT OF EXTERIOR, SHEAR, AND BEARING WALLS AND AT 5'-0" OC MAX AT NON-BEARING WALLS WITH SHEATHING ON ONE SIDE ONLY (NON-LOAD BEARING WALLS WITH SHEATHING ON BOTH SIDES DO NOT REQUIRE BRIDGING), OR AS
REQUIRED BY THE CFMF SUPPLIER.
8. MEMBERS SHALL BE UNPUNCHED WHERE USED FOR THE FOLLOWING: HEADERS AND SILLS OF
OPENINGS WIDER THAN 3’-0”, AND BUILT-UP BOX AND BACK-TO-BACK SECTIONS. PUNCH-OUTS SHALL BE LOCATED IN THE CENTER OF THE WEB WITH A MINIMUM SPACING OF 24” OC, HAVE A MAXIMUM WIDTH OF HALF THE MEMBER DEPTH OR 2 ½”, WHICHEVER IS LESS, AND A MAXIMUM LENGTH OF 4 ½”.
THE MINIMUM DISTANCE BETWEEN THE END OF THE MEMBER AND THE NEAR EDGE OF THE PUNCH-
OUT SHALL BE 12”.
9. COLD-FORMED METAL STUD SHALL BE 600S163-54 @ 16" OC AT PENTHOUSE WALLS
STRUCTURAL STEEL
1. FABRICATOR QUALIFICATIONS: FABRICATOR SHALL BE AISC CERTIFIED OR AN “APPROVED
FABRICATOR” IN ACCORDANCE WITH THE BUILDING CODE AND APPROVED BY THE AHJ. IN LIEU OF THE PREVIOUS, FABRICATOR SHALL INCLUDE IN THEIR BID THE SERVICES OF A SPECIAL INSPECTOR
TO PROVIDE IN-PLANT INSPECTION/TESTING SERVICES FOR WORK COMPLETED ON THE
FABRICATOR’S PREMISES TO MEET BUILDING CODE REQUIREMENTS. AT THE COMPLETION OF WORK, FABRICATOR SHALL SUBMIT A “CERTIFICATE OF COMPLIANCE” TO THE ARCHITECT AND AHJ STATING
THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH APPROVED CONSTRUCTION DOCUMENTS.
2. STRUCTURAL STEEL SHAPES AND CONNECTING COMPONENTS SHALL CONFORM TO THE FOLLOWING
MATERIAL SPECIFICATIONS UNO:
FOLLOWING MATERIAL SPECIFICATIONS:
WIDE FLANGE SHAPES ASTM A992, Fy = 50 KSI
HOLLOW STRUCTURAL SECTIONS (HSS)
RECTANGULAR & SQUARE ASTM A500, GRADE C, Fy = 50 KSI ROUND ASTM A500, GRADE C, Fy = 46 KSI
STEEL PIPE ASTM A53, GRADE B, Fy = 35 KSI OTHER STEEL SHAPES AND PLATES ASTM A36, Fy = 36 KSI
HIGH STRENGTH STRUCTURAL BOLTS ASTM F3125, GRADE A325N
COLUMN ANCHOR RODS ASTM F1554, GRADE 36
MACHINE BOLTS ASTM A307
THREADED RODS ASTM A36
WELDING ELECTRODES E70XX
DEFORMED BAR ANCHORS (DBA) ASTM A496, Fy = 70 KSI WELDED HEADED STUDS (WHS) ASTM A108, Fu = 65 KSI WELDED THREADED STUDS (WTS) ASTM A108, Fu = 65 KSI
3. CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE BUILDING SYSTEM AT ALL TIMES DURING THE ERECTION PROCESS. ELEMENTS HAVE BEEN DESIGNED FOR THE FINAL COMPLETED CONDITION
AND HAVE NOT BEEN INVESTIGATED FOR TEMPORARY LOADING DURING CONSTRUCTION.
INVESTIGATION OF THE STRUCTURAL ELEMENTS FOR ADEQUACY DURING THE STEEL ERECTION AND
CONSTRUCTION PROCESS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR TO
PROVIDE TEMPORARY SUPPORTS AS REQUIRED TO MAINTAIN STABILITY.
4. COLUMNS AND BEAMS WITH BASE, CAP OR END PLATES SHALL HAVE SQUARE CUT OR MILLED ENDS.
5. NON-METALLIC, NON-SHRINK, CHLORIDE FREE GROUT UNDER ALL COLUMN BASE PLATES AND BEAM BEARING PLATES SHALL CONSIST OF A PRE-MIXED PRODUCT COMPLYING WITH ALL REQUIREMENTS
OF ASTM C1107. THE 28-DAY COMPRESSIVE STRENGTH OF THE GROUT SHALL BE TWICE THE
FOUNDATION REQUIRED CONCRETE COMPRESSIVE STRENGTH, 5,000 PSI MINIMUM.
6. UNO, ALL STRUCTURAL STEEL PERMANENTLY EXPOSED TO THE WEATHER, INCLUDING ALL BRICK SHELF ANGLES AND EXTERIOR LINTELS, SHALL BE HOT DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123. ALL DAMAGED GALVANIZING SHALL BE REPAIRED IN ACCORDANCE WITH ASTM A780. STAINLESS AND WEATHERING STEELS, WHERE SPECIFIED, ARE EXEMPT FROM THIS
REQUIREMENT.
7. ALL BOLTS (HIGH STRENGTH, ANCHOR BOLTS, EXPANSION BOLTS, ADHESIVE ANCHORS, ETC.) SHALL BE INSTALLED WITH STEEL NUTS AND WASHERS. NUTS AND WASHERS FOR HIGH STRENGTH BOLTS
SHALL CONFORM TO ASTM A563 AND TO ASTM F436, RESPECTIVELY.
8. WELDING PROCEDURES, ELECTRODES, AND WELDER QUALIFICATIONS SHALL CONFORM TO THE
AMERICAN WELDING SOCIETY CODE D1.1, AISC STANDARDS, AND LOCAL CODE REQUIREMENTS.
9. ALL WELDS SHOWN ON THE DRAWINGS SHALL BE SHOP WELDS, UNO. WHERE SHOWN, FIELD
WELDING SHALL BE USED. CONTRACTOR MAY SUBSTITUTE FIELD WELDS FOR SHOP WELDS AT
THEIR DISCRETION. SHOP DRAWINGS SHALL CLEARLY NOTE ALL WELDING USING AWS A2.4 SYMBOLS.
10. WHERE CONTINUOUS ANGLES OR BENT PLATES ARE INDICATED, PROVIDE A CONTINUOUS BUTT WELD OR FULL PENETRATION WELD AT THE SPLICE POINTS, UNO. THE STEEL FABRICATOR MAY
SUBMIT AN ALTERNATE BOLTED CONNECTION DETAIL FOR APPROVAL.
11. COORDINATE WITH ALL OTHER TRADES WHICH STEEL INTERACTS. THIS INCLUDES BUT IS NOT LIMITED TO COORDINATING WITH MASONRY, PRECAST CONCRETE, CAST-IN-PLACE CONCRETE, JOIST, AND METAL DECK SUPPLIERS.
STEEL DECK
1. ALL STEEL DECK SHALL BE MANUFACTURED, DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST EDITION OF THE "DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND
ROOF DECKS" BY THE STEEL DECK INSTITUTE (SDI).
2. STEEL DECK & ACCESSORIES SHALL BE FABRICATED FROM STEEL PER ASTM A1008 OR A653.
3. DECK SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES:
A. 2” COMPOSITE DECK:
a. MINIMUM YIELD STRENGTH Fy = 50 KSI
b. DEPTH/GAGE: 2” / 20
c. MOMENT OF INERTIA (Ip): 0.407 IN4 / FT
d. SECTION MODULUS (Sp): 0.337 IN3 / FT
B. WIDE RIB ROOF DECK (TYPE B):
a. MINIMUM YIELD STRENGTH Fy = 50 KSI
b. DEPTH/GAGE: 1 1/2" / 20
c. MOMENT OF INERTIA (Ip): 0.197 IN4 / FT MIN
d. SECTION MODULUS (Sp): 0.224 IN3 / FT MIN
4. COMPOSITE DECK AND BARE METAL ROOF DECK SHALL BE ATTACHED TO SUPPORTING
STRUCTURAL MEMBERS BY 5/8” EFFECTIVE DIAMETER PUDDLE WELDS PLACED AT EACH DECK RIB OR 18 INCHES ON CENTER MAX. THIS WELD CAN BE OMITTED IN RIBS THAT HAVE SHEAR STUD CONNECTORS. SIDE LAPS BETWEEN ADJACENT UNITS ARE TO BE ATTACHED WITH #10 TEK SCREWS, CRIMP OR BUTTON PUNCH OR 5/8" EFFECTIVE ARCH SPOT WELDS AT 36 INCHES MAXIMUM (MINIMUM
2 SCREWS PER SPAN).
5. MINIMUM DECK BEARING SHALL BE 2" AT EXTERIOR SUPPORTS & 3" FOR INTERIOR SUPPORTS, UNO.
6. COMPOSITE DECK DESIGN IS INTENDED TO BE UNSHORED, UNO.
1. NO DIRECT ATTACHMENT TO UNDERSIDE OF METAL ROOF DECK IS ALLOWED UNLESS INDICATED ON THE STRUCTURAL DRAWINGS. ALL SUSPENDED LOADS, INCLUDING BUT NOT LIMITED TO, CEILINGS, LIGHT FIXTURES, DUCTWORK, PIPING, AND OTHER UTILITIES TO BE SUPPORTED FROM THE PRIMARY
STRUCTURAL MEMBERS OR SECONDARY SUPPORTS BETWEEN STRUCTURAL FRAMING.
COORDINATE HANGER AND/OR WIRE SUPPORTS WITH ASSOCIATED SPECIFICATIONS AND TRADES.
2. THE STEEL DECK SUPPLIER SHALL PROVIDE CLOSURE PLATES, AND ALL MISCELLANEOUS COLD-
FORMED STEEL NECESSARY TO COMPLETE THE WORK.
SUBMITTALS
1. THE CONTRACTOR SHALL DEVELOP AND SUBMIT A SUBMITTAL SCHEDULE INDICATING THE
NUMBER OF SHOP DRAWINGS TO BE SUBMITTED EACH WEEK OVER THE DURATION OF THE
PROJECT.
2. THE SUBMITTAL SCHEDULE PROVIDED BY THE CONTRACTOR IS NECESSARY TO PROVIDE
REASONABLE TIME TO PROCESS THE SCHEDULED SUBMITTALS. THE ENGINEER'S REVIEW
SCHEDULE WILL BE DETERMINED USING THE SUBMITTAL SCHEDULE PROVIDED BY THE
CONTRACTOR.
3. REVIEW OF SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR FROM CONFORMANCE WITH
THE INTENT OF THE DRAWINGS. REVIEW DOES NOT IMPLY OR STATE THAT THE FABRICATOR HAS
CORRECTLY INTERPRETED THE CONSTRUCTION DOCUMENTS.
4. COPIES OF THE CONTRACT DOCUMENTS SHALL NOT BE SUBMITTED AS SHOP DRAWINGS.
CONTRACT DRAWINGS SHOW ONLY GENERAL DESIGN INTENT. FINAL SHOP DRAWING SECTIONS
SHALL PROVIDE SIZES, LAYOUT, EXACT DIMENSIONS, ELEVATIONS, GRADES OF MATERIALS, ETC, SPECIFIC TO EACH LOCATION.
5. SHOP DRAWINGS SHALL BE REVIEWED AND STAMPED BY THE GENERAL CONTRACTOR OR
CONSTRUCTION MANAGER PRIOR TO SUBMITTING TO ENGINEER. REQUEST FOR INFORMATION
FOR ITEMS SUCH AS OVERALL BUILDING GEOMETRY, ELEVATIONS, ETC. SUBMITTED THROUGH
SHOP DRAWINGS SHALL BE DETERMINED BY THE CONTRACTOR. IF GEOMETRY CANNOT BE
DETERMINED FROM THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL SUBMIT AN RFI AND
COORDINATE THE RESPONSE WITH ALL AFFECTED TRADES PRIOR TO FABRICATION.
6. ANY CHANGES, SUBSTITUTION REQUESTS, OR DEVIATIONS FROM THE CONTRACT DOCUMENTS
SHALL BE CLOUDED BY THE SUPPLIER AND THE CONTRACTOR. SUCH ITEMS NOT CLOUDED BY
THE SUBMITTING PARTY SHALL NOT BE CONSIDERED ALLOWED AFTER THE ENGINEER’S REVIEW
UNLESS NOTED ACCORDINGLY BY THE ENGINEER IN WRITING.
7. DELEGATED DESIGN SUBMITTAL CALCULATIONS AND SHOP DRAWINGS SHALL BE SIGNED AND
SEALED BY THE PREPARING ENGINEER REGISTERED IN THE STATE THE PROJECT IS LOCATED AND
SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW WITH THE SHOP DRAWING SUBMITTAL.
ONCE REVIEWED, CONTRACTOR SHALL FORWARD TO THE BUILDING DEPARTMENT FOR
APPROVAL. FABRICATION AND/OR INSTALLATION OF DEFERRED SUBMITTAL ITEMS SHALL NOT
OCCUR UNTIL APPROVAL OF THE BUILDING DEPARTMENT IS RECEIVED.
8. SUBMITTALS EXPECTED TO BE REVIEWED BY THE ENGINEER ARE PROVIDED IN THE TABLE
FOLLOWING THESE NOTES. THE SUBMISSION REQUIREMENTS FOR PRODUCT DATA, SHOP
DRAWINGS, TEST RESULTS, CALCULATIONS, AND BUILDING DEPARTMENT REVIEW ARE INDICATED.
DEFERRED SUBMITTALS PER IBC SECTION 107.3.4.1 ARE INDICATED.
CONCRETE TOPPING SLABS
1. TOPPING THICKNESS SHOWN ON PLAN IS NOMINAL. ACTUAL THICKNESS WILL VARY DUE TO
SUPPORTING MEMBER CAMBER AND DEFLECTIONS. PROVIDE THICKNESS AS REQUIRED TO ACHIEVE
A LEVEL FLOOR WITH A FINAL THICKNESS NO LESS THAN 1/2 INCH LESS THAN SPECIFIED.
2. UNO IN PLAN OR DETAIL, PROVIDE (1) #4 IN TOPPING SLAB EACH SIDE OF OPENINGS EXCEEDING 12
INCHES IN SIZE. EXTEND REINFORCING 1’-6” PAST CORNER OF OPENING.
3. DO NOT PROVIDE CONTROL JOINTS IN TOPPING SLABS.
4. CONDUITS IN THE TOPPING SLAB SHALL BE LIMITED TO THE LARGER OF ¾-INCH OR ONE-FOURTH
THE TOPPING THICKNESS AND SPACED A MINIMUM OF THREE DIAMETERS ON CENTER.
CAST-IN-PLACE CONCRETE MIX DESIGNS
1. THE CONCRETE MIX TABLE SHOWN BELOW SHALL APPLY TO ALL CONCRETE MIX DESIGNS USED FOR
STRUCTURAL ITEMS IN THIS PROJECT. MIX DESIGN SUBMITTALS SHALL BE IDENTIFIED FOR
INTENDED STRUCTURAL USE AND SUBMITTED TO THE OWNER’S REPRESENTATIVE AND ENGINEER
FOR REVIEW PRIOR TO PLACING ANY CONCRETE. WHEN CONCRETE MIX DESIGNS ARE A
DELEGATED DESIGN ITEM, THE SUBMITTED MIX DESIGN SHALL BEAR THE SEAL AND SIGNATURE OF
THE ENGINEER RESPONSIBLE FOR THEIR DESIGN.
A. EXPOSURE CLASSES ARE F0, S0, W0, C0 UNLESS NOTED OTHERWISE IN THE TABLE ABOVE.
B. THE WATER-CEMENT RATIO IN CONCRETE CONTAINING POLYSILICATE ADMIXTURES SHALL
CONFORM TO THE REQUIREMENTS OF THE ADMIXTURE SUPPLIER. SUBMIT ADMIXTURE PRODUCT
DATA FOR REVIEW WITH THE MIX DESIGN SUBMITTAL. REFER TO THE PROJECT SPECIFICATIONS
FOR ADDITIONAL REQUIREMENTS.
C. CONCRETE MIXES SHALL COMPLY WITH ACI 318 SECTION 19.3 FOR THE EXPOSURE CLASSES
INDICATED THE TABLE ABOVE. FOR CLASSES F1 THROUGH F3, AIR ENTRAINMENT SHALL MEET
THE REQUIREMENTS OF ACI-318 TABLE 19.3.3.1.
D. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150 OR C-595 OF THE TYPE SPECIFIED IN THE
TABLE ABOVE.
E. AGGREGATE FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33. AGGREGATE
FOR LIGHT WEIGHT CONCRETE SHALL CONFORM TO ASTM C-330.
F. VERIFY THE UNIT WEIGHT OF LIGHT WEIGHT CONCRETE IN ACCORDANCE WITH ASTM C567.
G. WATER SHALL BE CLEAR, POTABLE AND SHALL CONFORM TO ASTM C-94.
H. CONCRETE MIXING OPERATION SHALL CONFORM TO ASTM C-94.
2. REFER TO PROJECT SPECIFICATION FOR ADDITIONAL INFORMATION.
3. FLY ASH MAY BE USED TO REPLACE 15% TO 25% OF PORTLAND CEMENT. FLY ASH SHALL CONFORM TO ASTM C618, TYPE F. PERCENTAGE LISTED IS BY WEIGHT OF TOTAL CEMENTITIOUS MATERIAL INCLUDING ASTM C150, C595, C845, AND C1157 CEMENT. DO NOT USE FLY ASH IF CONTENT WITHIN
THE PERCENTAGES SHOWN CANNOT BE ACHIEVED.
SLABS ON GRADE, TOPPING SLABS & ELEVATED FLOORS SHALL HAVE A MAXIMUM SHRINKAGE RATE OF 0.035% IN NW AT 28 DAYS PER ASTM C157 (CURING TEST SPECIMENS TO BE CONSISTENT WITH FIELD CONDITIONS). RESULTS OF TESTING SHALL BE SUBMITTED TO ENGINEER WITH CONCRETE MIX
SUBMITTAL.
GENERAL STRUCTURAL NOTES
CONCRETE CONSTRUCTION
1. THESE NOTES APPLY TO CONCRETE USED IN BUILDING CONSTRUCTION ONLY. SEE CIVIL/SITE WORK
DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF ACI 301 AND ACI 318.
3. REFER TO DRAWINGS OF OTHER DISCIPLINES AND VENDOR DRAWINGS FOR EMBEDDED ITEMS AND
RECESSES NOT SHOWN ON STRUCTURAL DRAWINGS.
4. SLEEVES OR OPENINGS, EXCEPT AS DETAILED ON THE STRUCTURAL DRAWINGS, SHALL NOT BE PLACED IN WALLS, JOISTS, BEAMS, GIRDERS, OR IN SLABS ADJACENT TO A COLUMN (WITHIN A
DISTANCE EQUAL TO THE SLAB THICKNESS) UNLESS APPROVED BY THE ENGINEER. PLUMBING,
MECHANICAL, & ELECTRICAL CONTRACTORS SHALL SUBMIT SIZES AND LOCATIONS OF ALL
PENETRATIONS IN STRUCTURAL SLABS FOR THE ENGINEER'S APPROVAL BEFORE THE SLAB IS
PLACED. ALL PIPE PENETRATIONS THROUGH SLABS SHALL BE SLEEVED AND REINFORCING SHALL NOT BE CUT. CORING OF CONCRETE AFTER PLACEMENT IS NOT PERMITTED UNLESS APPROVED BY
THE ENGINEER.
5. PROVIDE CONSTRUCTION JOINTS IN ACCORDANCE WITH ACI 318. SUBMIT DRAWINGS SHOWING
PLACEMENT SEQUENCE FOR ENGINEERING REVIEW.
6. ALL CONCRETE SHALL BE MECHANICALLY CONSOLIDATED IN ACCORDANCE WITH ACI 309.
7. PROVIDE A FORMED CONSTRUCTION KEYWAY BETWEEN ALL HORIZ AND VERT PLACEMENT EDGES
EXCEPT CONCRETE TOPPING SLABS. PROVIDE WATERSTOPS FOR ALL CONSTRUCTION JOINTS
BELOW WATER TABLE AND WHERE INTERIOR SLAB ON GRADE IS BELOW EXTERIOR GRADE.
8. INTENTIONALLY ROUGHEN ALL CONCRETE SURFACES TO A MINIMUM 1/4" AMPLITUDE AGAINST
WHICH CONCRETE IS TO BE PLACED UNO.
9. ALL EDGES OF PERMANENTLY EXPOSED CONCRETE SURFACES SHALL BE CHAMFERED 3/4", UNO.
CONCRETE REINFORCEMENT
1. REINFORCING STEEL SHALL BE ASTM A615, GRADE 60, UNO.
2. REINFORCING STEEL TO BE WELDED SHALL BE ASTM A706, GRADE 60. NO WELDING OF
REINFORCEMENT SHALL BE PERMITTED UNLESS SPECIFICALLY CALLED FOR OR REVIEWED AND
APPROVED BY THE ENGINEER.
3. DEFORMED BAR ANCHORS (DBA) SHALL BE PROVIDED IN ACCORDANCE WITH NELSON STUD
WELDING, INC ICC ESR 2907. ANCHORS SHALL BE SHOP WELDED TO STEEL USING A STUD WELDING
GUN.
4. CONCRETE COVER REQUIREMENTS FOR CAST-IN-PLACE, NON-PRESTRESSED REINFORCEMENT
UNLESS OTHERWISE NOTED ON DETAILS SHALL BE AS FOLLOWS:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"
FORMED CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 BARS AND LARGER: 2"
#5 BARS AND SMALLER: 1 1/2"
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH EARTH:
SLABS, WALLS, AND JOISTS:
#14 AND #18 BARS: 1 1/2"
#11 BARS AND SMALLER: 1"
BEAMS, COLUMNS:
PRIMARY REINFORCEMENT: 1 1/2"
TIES, STIRRUPS, SPIRALS: 1 1/2"
5. REINFORCING BAR SPLICES SHALL BE AS INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH
THE REQUIREMENTS OF ACI 318 AND THE REINFORCING SPLICE LENGTH SCHEDULE.
6. ALL HORIZONTAL WALL AND BEAM REINFORCING SHALL BEND AROUND ALL CORNERS, LAP WITH
INTERSECTING REINFORCEMENT, AND LAP SHALL CONFORM TO LAP SPLICE AND ANCHORAGE
SCHEDULE PROVIDED, UNO.
7. ALL REINFORCEMENT SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES IN
CONFORMANCE WITH CRSI MANUAL OF STANDARD PRACTICE AND ACI 315 DURING CONCRETE
PLACEMENT. NO WET SETTING OF REINFORCEMENT OR ACCESSORIES.
8. PROVIDE CORROSION RESISTANT ACCESSORIES SUCH AS PLASTIC COATED (NOT PLASTIC TIPPED)
OR STAINLESS-STEEL CHAIRS IN ALL EXPOSED CONCRETE CONSTRUCTION. PRECAST CONCRETE
CHAIRS OR SAND PLATE CHAIRS SHALL BE USED FOR THE SUPPORT OF REINFORCING ON GRADE.
CONCRETE BLOCK OR CLAY MASONRY BRICK ARE NOT PERMITTED.
9. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS
SPECIFICALLY DETAILED AS SUCH OR APPROVED BY THE ENGINEER IN WRITING.
10. WELDED WIRE REINFORCING (WWR) SHALL COMPLY WITH ASTM A1064. USE ONLY FLAT SHEETS.
LAP ALL WWR AT LEAST TWO FULL WIRE SPACING OR 8", WHICHEVER IS GREATER. ALL WWR SHALL BE CHAIRED TO ITS PROPER HEIGHT AND MAINTAINED AT THE PROPER LEVEL THROUGHOUT THE
CONCRETE PLACING OPERATION. LIFTING OF WWR WITH A HOOK DURING CONCRETE PLACEMENT
SHALL NOT BE PERMITTED.
11. MECHANICAL COUPLERS SHALL BE TYPE 2 COUPLERS CAPABLE OF SUSTAINING 125% Fy.
12. ALL BARS INTERRUPTED BY STRUCTURAL STEEL SHALL EXTEND TO WITHIN 1" OF STRUCTURAL
STEEL FLANGE OR WEB AND HAVE A 90 DEGREE HOOK, UNO.
13. REINFORCING STEEL PROJECTING FROM THE CONCRETE OR MASONRY AND CONNECTING DIRECTLY
TO STRUCTURAL STEEL WHERE DIMENSIONAL CONTROL IS CRITICAL OR WHERE SPECIFICALLY
NOTED ON THE PLAN SHALL BE TREATED AS AN ANCHOR ROD AND SHALL CONFORM TO THE
TOLERANCES SPECIFIED IN SECTION 7.5 OF AISC 303-16 "CODE OF STANDARD PRACTICE FOR STEEL
BUILDINGS AND BRIDGES".
14. WELDING OF REINFORCEMENT SHALL CONFORM TO THE 2017 EDITION OF AWS D1.4 "STRUCTURAL
WELDING CODE - REINFORCING STEEL". WELDED CONNECTIONS NOT SPECIFIED ON THE PLANS
SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE ENGINEER.
15. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND
SPACING AS THE VERTICAL REINFORCING, RESPECTIVELY, UNO.
DESIGN CRITERIA
1. ALL CONSTRUCTION, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THESE DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND REGULATIONS OF THE 2018 INTERNATIONAL BUILDING CODE (IBC), AS ADOPTED AND AMENDED BY THE CITY OF FLAGSTAFF
HEREAFTER REFERRED TO AS THE BUILDING CODE.
2. MATERIAL SPECIFIC DESIGN STANDARDS LISTED IN THESE GENERAL NOTES ARE THE VERSION
REFERENCED BY THE BUILDING CODE. IF NOT REFERENCED BY THE BUILDING CODE, USE THE
LATEST EDITION APPROVED BY THE AUTHORITY HAVING JURISDICTION ON THE DATE OF THE
PERMIT ISSUANCE.
3. RISK CATEGORY II
4. EXISTING DEAD LOADS
ROOF - TOTAL 25 PSF (INCLUDES STRUCTURE SELF WEIGHT)
FLOOR 63 PSF (INCLUDES STRUCTURE SELF WEIGHT)
5. EXISTING LIVE LOADS
STAIRS & EXIT WAYS 100 PSF
OFFICES (R) 65 PSF (INCLUDES 15 PSF PARTITIONS)
LOBBIES 100 PSF
CORRIDORS 100 PSF
UPPER LEVEL CORRIDORS (R) 80 PSF
LIGHT STORAGE 125 PSF
ROOF LIVE LOAD 20 PSF
FLOOR LIVE LOADS NOTED ‘(R)’ HAVE BEEN REDUCED PER THE BUILDING CODE.
6. SNOW LOADS
GROUND SNOW LOAD, Pg 60 PSF FLAT-ROOF SNOW LOAD, Pf 42.0 PSF SNOW EXPOSURE FACTOR, Ce 1.0 THERMAL FACTOR, Ct 1.0 SNOW LOAD IMPORTANCE FACTOR, ls 1.10
DRIFT LOADS (EXISTING STRUCTURES CHECKED FOR
DRIFTING SNOW OF ??.?? PSF
7. WIND LOADS
BASIC DESIGN WIND SPEED (3-SEC GUST), V 115 MPH
ALLOWABLE STRESS DESIGN WIND SPEED, Vasd 89.1 MPH
EXPOSURE CATEGORY C
TOPOGRAPHIC FACTOR, Kzt 1.0 AIR DENSITY FACTOR, Ke 1.0 INTERNAL PRESSURE COEFFICIENT, GCpi +/- 0.18
8. SEISMIC LOADS
SITE LATITUDE 35.1824
SITE LONGITUDE -111.6688
SITE CLASS D
MAPPED SPECTRAL RESPONSE ACCELERATIONS SS = 31.4
S1 = 9.7
DESIGN SPECTRAL RESPONSE ACCELERATIONS SDS = 32.4
SD1 = 15.5
SEISMIC DESIGN CATEGORY C
IMPORTANCE FACTOR, Ie 1.25
SEISMIC FORCE RESISTING SYSTEM: INTERMEDIATE REINFORCED MASONRY
SHEAR WALLS.
RESPONSE MODIFICATION FACTOR, R 3.5
OVERSTRENGTH FACTOR, Ωo 2.5 DEFLECTION AMPLIFICATION FACTOR, Cd 2.25 REDUNDANCY FACTOR, ρ 1.0
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
SEISMIC RESPONSE COEFFICIENT, Cs 0.078
9. RAIN INTENSITY 3 INCH/HOUR
SLABS-ON-GROUND/GRADE
1. VERIFY ALL TOP OF SLAB ELEVATIONS COMPLY WITH THE ARCHITECTURAL DRAWINGS. SEE
ARCHITECTURAL FOR LOCATION AND EXTENT OF SPECIAL FINISHES OR TREATMENTS TO EXPOSED
CONCRETE.
2. ALL INTERIOR SLABS ON GROUND/GRADE SHALL BE CAST ON A 15 MIL VAPOR RETARDER INSTALLED
PER MANUFACTURER’S WRITTEN INSTRUCTIONS, PLACED OVER CRUSHED ROCK DRAINAGE
MATERIAL TO FORM A CAPILLARY BREAK OF THICKNESS NOTED ON DRAWINGS, BUT NOT LESS THAN
THAT PRESCRIBED BY THE GEOTECHNICAL ENGINEER.
3. CONTROL (CONTRACTION OR CONSTRUCTION) JOINTS SHALL BOUND ALL CONCRETE SLABS ON
GROUND/GRADE AS SHOWN ON THE DRAWINGS. WHERE NOT SHOWN ON THE DRAWINGS,
CONTROL JOINTS SHALL BE LOCATED SUCH THAT THE ENCLOSED AREA IS RELATIVELY SQUARE
WITH A MAXIMUM ASPECT RATIO OF 1.5:1 AND DOES NOT EXCEED A SPACING EQUAL TO 3 TIMES (IN
FEET) THE SLAB THICKNESS (IN INCHES) OR 15 FEET WHICHEVER IS LESS.
4. GENERAL CONTRACTOR SHALL SUBMIT CONTROL JOINT SHOP DRAWINGS AND PLACING
SEQUENCES FOR APPROVAL PRIOR TO CONCRETE PLACEMENT. KEYED JOINTS NEED ONLY OCCUR
AT CONSTRUCTION JOINTS. ALL CONTRACTION JOINTS MAY BE SAWCUT, UNO.
5. THE SLAB ON GROUND/GRADE IS NOT DESIGNED TO SUPPORT TRAFFIC FROM CRANES OR OTHER
HEAVY CONSTRUCTION VEHICLES. CONTRACTOR SHALL REPAIR OR REPLACE DAMAGED CONCRETE
SLABS.
6. REINFORCE SLABS, INCLUDING STAIR PANS AND LANDINGS, WITH 6X6 W2.1XW2.1 WWR UNO.
7. ALL PIPING AND CONDUIT INSTALLED BELOW SLABS ON GROUND/GRADE SHALL BE INSTALLED ENTIRELY BELOW THE BOTTOM OF THE SLAB, WITH NO ENCROACHMENT INTO THE BOTTOM OF THE
SLAB.
POST-INSTALLED ANCHORS
1. UNO, THE FOLLOWING APPLIES TO ALL POST-INSTALLED ANCHORAGE INTO HARDENED
CONCRETE OR MASONRY WHICH INCLUDES TYPES SUCH AS EXPANSION, WEDGE, SLEEVE,
ADHESIVE / EPOXY, SHOT-PIN, SCREW AND UNDERCUT.
2. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED.
3. CONTRACTOR SHALL OBTAIN APPROVAL FROM ENGINEER OF RECORD PRIOR TO USING POST-
INSTALLED ANCHORS FOR MISSING, DAMAGED OR MISPLACED CAST-IN-PLACE ANCHORS.
4. CARE SHALL BE GIVEN TO AVOID CONFLICTS WITH EXISTING REBAR OR EMBEDDED CONDUIT
WHEN DRILLING HOLES. HOLES SHALL BE DRILLED AND CLEANED PER THE MANUFACTURER’S
INSTRUCTIONS.
5. MAINTAIN A MINIMUM OF 2 INCHES FROM EXISTING REINFORCEMENT, CONDUIT, POST-
TENSIONING (WHERE OCCURS), ETC. USE NON-DESTRUCTIVE TESTING TO LOCATE PRIOR TO
DRILLING, CORING OR SHOOTING PINS INTO THE EXISTING CONCRETE OR MASONRY. FOR
INSTALLATION DEEPER THAN 3 INCHES USE GROUND PENETRATING RADAR OR X-RAY METHODS.
6. ALL ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS, MANUFACTURER’S RECOMMENDATIONS AND ALL APPLICABLE ICC-ES REPORTS, INCLUDING, BUT
NOT LIMITED TO, ALL ANCHOR SPACINGS, EMBEDMENTS AND EDGE DISTANCES.
7. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE
ENGINEER PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT
THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE
SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY HAVING AN ICC ESR SHOWING
COMPLIANCE WITH THE BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION
CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE
ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE AND INSTALLATION
TEMPERATURES.
8. EMBEDMENT REFERS TO THE FINAL INSTALLED EFFECTIVE DEPTH “Hef”. ALL ANCHORS SHALL
HAVE EMBEDMENT NOTED OR EMBEDMENT AS RECOMMENDED BY MANUFACTURER WHERE NO
EMBEDMENT IS SHOWN. REQUIRED ANCHOR HOLE DEPTH FOR INSTALLATION MAY BE DEEPER.
9. IF THE FULL ANCHOR EMBEDMENT DEPTH, SPACING OR EDGE DISTANCE CANNOT BE ACHIEVED, NOTIFY THE ENGINEER.
10. STEEL ANCHORING ELEMENTS SHALL BE THE SIZE AND GRADE SHOWN ON THE DRAWINGS AND
MUST BE CLEAN, DRY AND FREE OF ANY OIL CONTAMINANTS. DO NOT INCREASE OR DECREASE
SIZE OF ANCHOR WITHOUT APPROVAL OF ENGINEER.
11. ALL PERSONNEL INSTALLING POST-INSTALLED ANCHORS SHALL BE TRAINED BY THE
MANUFACTURER ON PROPER INSTALLATION TECHNIQUE. TRAINING DOCUMENTATION FROM THE
MANUFACTURER SHALL BE AVAILABLE UPON REQUEST.
12. INSTALLATION OF ADHESIVE ANCHORS IN HORIZONTAL TO VERTICALLY OVERHEAD ORIENTATION SHALL BE DONE BY A CERTIFIED ADHESIVE ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI AND IN ACCORDANCE WITH ACI 318. PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED
TO THE ENGINEER FOR APPROVAL PRIOR TO COMMENCEMENT OF INSTALLATION.
13. EXPANSION BOLTS IN CONCRETE MASONRY SHALL BE ONE OF THE FOLLOWING:
a. HILTI KWIK BOLT TZ2 MASONRY ANCHORS (ICC ESR-4561)
b. DEWALT – POWER STUD+SD1 (ICC ESR-2966)
c. SIMPSON STRONG-TIE STRONG BOLT-2 WEDGE ANCHOR (IAMPO UES ER-240)
14. SCREW ANCHORS IN CONCRETE MASONRY SHALL BE ONE OF THE FOLLOWING:
a. HILTI KH-EZ SCREW ANCHOR (ICC ESR-3056)
b. DEWALT – SCREW BOLT+, SCREW ANCHOR (ICC ESR-4042)
c. SIMPSON STRONG-TIE TITEN HD SCREW ANCHORS (ICC ESR-1056)
15. ADHESIVE ANCHORS IN MASONRY SHALL BE ONE OF THE FOLLOWING:
a. HILTI HIT-HY 270 FAST CURE ADHESIVE ANCHORING SYSTEM (ICC ESR-4144 FOR MULTI
WYTHE BRICK, ICC ESR-4143 FOR CMU)
b. HILTI HIT-HY 200 V3 ADHESIVE ANCHORING SYSTEM (ICC ESR-4878)
c. DEWALT AC100+GOLD FAST CURE ADHESIVE ANCHORING SYSTEM (ICC ESR-3200)
d. SIMPSON STRONG-TIE SET-3G ADHESIVE ANCHORING SYSTEM (ICC ESR-4844)
16. EXPANSION BOLTS IN CONCRETE SHALL BE ONE OF THE FOLLOWING:
a. HILTI KWIK BOLT TZ2 CONCRETE ANCHORS (ICC ESR-4266)
b. DEWALT POWER-STUD+SD1 (ICC ESR-2818), POWER STUD +SD2 (ICC ESR-2502)
c. SIMPSON STRONG-TIE STRONG-BOLT 2 WEDGE ANCHORS (ICC ESR-3037)
17. SCREW ANCHORS IN CONCRETE SHALL BE ONE OF THE FOLLOWING:
a. HILTI HUS-EZ SCREW ANCHORS (ICC ESR-3027)
b. DEWALT SCREW BOLT+, SCREW ANCHORS (ICC ESR-3889)
c. SIMPSON STRONG-TIE TITEN HD SCREW ANCHORS (ICC ESR-2713)
18. ADHESIVE ANCHORS IN CONCRETE SHALL BE ONE OF THE FOLLOWING:
a. HILTI HIT-HY 200 V3 ADHESIVE ANCHORING SYSTEM WITH SAFESET (ESR-4868) (FAST
CURE APPLICATIONS)
b. HILTI RE-500 V3 ADHESIVE ANCHORING SYSTEM (ICC ESR-3814)
c. HILTI RE-100 ADHESIVE ANCHORING SYSTEM (ICC ESR-3829) (STANDARD CURE
APPLICATIONS)
d. DEWALT AC200+ ADHESIVE ANCHORING SYSTEM (ICC ESR-4027) (FAST CURE
APPLICATIONS)
e. DEWALT PURE 220+ ADHESIVE ANCHORING SYSTEM (ICC ESR-5144) (STANDARD CURE
APPLICATIONS)
f. SIMPSON STRONG-TIE SET-3G ADHESIVE ANCHORING SYSTEM (ICC ESR-4057) (STANDARD
CURE APPLICATIONS)
g. SIMPSON STRONG-TIE AT-3G ADHESIVE ANCHORING SYSTEM (ICC ESR-5026) (FAST CURE
APPLICATIONS)
19. ANCHORS ARE NOT TO BE INSTALLED UNTIL CONCRETE OR GROUT HAS REACHED IT’S…
This is the start of the file's text. The full file is on GovTribe.