Attachment_II_-_Addendum_1_REVISED_Construction_Plans_Sheets_C-07_C-08_C-21.pdf
PDF 9 MB Posted
- Solicitation number
- 252769MM
- Issued by
- Sarasota County, Siesta Key CDP, Florida
About this file
This addendum contains revised construction plans for the Honore Avenue Reclaimed Water Main Extension Phase 2B project prepared by Sarasota County in partnership with Kimley-Horn and Associates, Inc. The addendum includes three revised sheets (C-07, C-08, and C-21) dated September 2025 and digitally signed by Ashley M. Miele, P.E. (Florida Professional Engineer License No. 66476) on November 7-11, 2025. Sheet C-07 provides the key plan, Sheet C-08 presents plan and profile details for stations 100+00 through 102+60, and Sheet C-21 details construction specifications. The project involves the installation of approximately 5,500 linear feet of reclaimed water transmission main using specialized techniques including 20-inch and 8-inch horizontal directional drill (HDD) installations and a 20-inch jack and bore in a 36-inch casing. The bid deadline is December 3, 2025, with a contract duration of 300 calendar days. The work is located in Osprey, Florida (Section 07, Township 38S, Range 19E).
The construction plans specify a 20-inch nominal DR-18 PVC carrier pipe with a 30-inch steel casing featuring 0.562-inch wall thickness and two-piece casing spacer assembly with 2-inch-wide runners. The project is funded through a Southwest Florida Water Management District (SWFWMD) grant, which requires compliance with federal provisions including United States-produced iron and steel products and minority and small business participation reporting for projects exceeding $100,000 in cooperative funding. Liquidated damages are set at $400 per day for substantial completion delays and $100 per day for final acceptance delays. Performance and payment bonds are mandatory, along with comprehensive insurance requirements including workers' compensation, commercial general liability, automobile liability, and umbrella/excess liability coverage. Contractors must demonstrate relevant experience, including installation of at least 1,000 linear feet of 16-inch or larger diameter pressure pipe and pipeline work involving lane closures, with experience from the past 10 years required.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KEY SHEET C-07
DATE
AS SHOWN
DATE:
SHEET NUMBER
No. REVISIONS DATE BY CHECKED BY
SCALE
DESIGNED BY
DRAWN BY
KHA PROJECT LICENSED PROFESSIONAL
SHEET NUMBER
No. REVISIONS DATE BY
DATE
AS SHOWN
CHECKED BY
SCALE
DESIGNED BY
DRAWN BY
KHA PROJECT
DATE:
LICENSED PROFESSIONAL
WWW.KIMLEY-HORN.COM REGISTRY NO. 35106
1800 2ND STREET, SUITE 900, SARASOTA, FL 34236
PHONE: 941-379-7600
HONORE AVE RECLAIMED
WATERMAIN EXTENSION PH2B
PREPARED FOR
SARASOTA COUNTY
© 2025 KIMLEY-HORN AND ASSOCIATES, INC.
FLSARASOTA COUNTY
66476
048048155
SEPTEMBER 2025
MSB
NLP
AMM
NOT FOR CONSTRUCTION
NORTH
STATE OF FLORIDA,
PROFESSIONAL ENGINEER,
LICENSE NO. 66476
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ASHLEY M. MIELE, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
ASHLEY M. MIELE, P.E.Digitally signed by Ashley M Miele Date:
2025.11.07 09:24:11-05'00'
PLAN AND PROFILE
[100+00 - 102+60] C-08
N
DATE
AS SHOWN
DATE:
SHEET NUMBER
No. REVISIONS DATE BY CHECKED BY
SCALE
DESIGNED BY
DRAWN BY
KHA PROJECT LICENSED PROFESSIONAL
SHEET NUMBER
No. REVISIONS DATE BY
DATE
AS SHOWN
CHECKED BY
SCALE
DESIGNED BY
DRAWN BY
KHA PROJECT
DATE:
LICENSED PROFESSIONAL
WWW.KIMLEY-HORN.COM REGISTRY NO. 35106
1800 2ND STREET, SUITE 900, SARASOTA, FL 34236
PHONE: 941-379-7600
HONORE AVE RECLAIMED
WATERMAIN EXTENSION PH2B
PREPARED FOR
SARASOTA COUNTY
© 2025 KIMLEY-HORN AND ASSOCIATES, INC.
FLSARASOTA COUNTY
66476
048048155
SEPTEMBER 2025
MSB
NLP
AMM
NOT FOR CONSTRUCTION
STATE OF FLORIDA,
PROFESSIONAL ENGINEER,
LICENSE NO. 66476
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ASHLEY M. MIELE, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
ASHLEY M. MIELE, P.E.Digitally signed by Ashley M Miele Date:
2025.11.07 09:26:19-05'00'
DATE
AS SHOWN
DATE:
SHEET NUMBER
No. REVISIONS DATE BY CHECKED BY
SCALE
DESIGNED BY
DRAWN BY
KHA PROJECT LICENSED PROFESSIONAL
SHEET NUMBER
No. REVISIONS DATE BY
DATE
AS SHOWN
CHECKED BY
SCALE
DESIGNED BY
DRAWN BY
KHA PROJECT
DATE:
LICENSED PROFESSIONAL
WWW.KIMLEY-HORN.COM REGISTRY NO. 35106
1800 2ND STREET, SUITE 900, SARASOTA, FL 34236
PHONE: 941-379-7600
HONORE AVE RECLAIMED
WATERMAIN EXTENSION PH2B
PREPARED FOR
SARASOTA COUNTY
© 2025 KIMLEY-HORN AND ASSOCIATES, INC.
FLSARASOTA COUNTY
66476
048048155
SEPTEMBER 2025
MSB
NLP
AMM
NOT FOR CONSTRUCTION
CONSTRUCTION DETAILS C-21
APPROX. LIMITS OF CARRIER
PIPE BELL O.D.
PROP. 20" NOMINAL DR-18
PVC CARRIER PIPE
PROP. TWO PIECE CASING SPACER
ASSEMBLY WITH 2" WIDE RUNNERS
PROP. UPPER SPACERS TO EXTEND
ABOVE CARRIER PIPE BELL O.D.
PROP. 30" STEEL CASING
(0.562" WALL THICKNESS)
STATE OF FLORIDA,
PROFESSIONAL ENGINEER,
LICENSE NO. 66476
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ASHLEY M. MIELE, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
ASHLEY M. MIELE, P.E.Digitally signed by Ashley M Miele Date:
2025.11.11 19:30:50-05'00'
| FLAT_C-07 KEY SHEET (ADDM #1)_SS |
| FLAT C-08 PLAN AND PROFILE (100+00 - 102+60) (ADDM #1)_SS |
| FLAT C-21 CONSTRUCTION DETAILS (ADDM #1)_SS |
File details come from the government source that posted it. Updated .