This is an Attachment A document listing service locations and equipment specifications for cafeteria grease exhaust system cleaning and ANSUL fire suppression services at Metro's Headquarters (USG) facility. The scope of work encompasses cleaning and maintenance of five grease exhaust systems located in the 3rd and 4th floor cafeteria areas, including front kitchen, back kitchen, and over-stove hood systems with associated components such as filters, baffles, air plenums, troughs, and exhaust ductwork. The systems contain a combined total of 20 filters across the cafeteria locations. Additionally, two ANSUL R-102 wet-chemical fire suppression systems are to be serviced, one in the front kitchen and one in the back kitchen, each containing two tanks. Grease exhaust system cleaning is required on a quarterly service frequency, while ANSUL fire suppression system maintenance is required semi-annually.
The document provides detailed equipment specifications and component lists for each location but does not specify pricing terms, contract duration, renewal options, response deadlines, or funding sources. No information regarding incumbent contractors, set-asides, bidders' conferences, site visit requirements, or award dates is included in this attachment.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT A
CAFETERIA GREASE EXHAUST SYSTEM
CLEANING AND ANSUL FIRE SUPPRESSION
SERVICES
LIST OF LOCATIONS AND EQUIPMENT
OP142160
Grease Exhaust Systems - Metro’s Headquarters (USG) 3rd Floor Cafeteria
# Location System Component Number of Filters
Service Frequency
3rd Floor Cafeteria Front Kitchen
Front Kitchen Grease Exhaust System
Main Hood, Backsplash, Filters, Baffles, Air Plenums, Troughs, Exhaust Ductwork
8 Quarterly
3rd Floor Cafeteria Back Kitchen
Back Kitchen Grease Exhaust System
Soup Hood, Backsplash, Filters, Baffles, Air Plenums, Troughs, Exhaust Ductwork
6 Quarterly
3rd Floor Cafeteria Back Kitchen
Back Kitchen Grease Exhaust System
Over-Stove Hood, Backsplash, Filters, Baffles, Air Plenums, Troughs, Exhaust Ductwork
6 Quarterly
4 4th Floor Roof Front Kitchen Grease
Exhaust System Exhaust Fan, Fan Housing, Diverters N/A Quarterly
5 4th Floor Roof Back Kitchen Grease
Exhaust System Exhaust Fan, Fan Housing, Diverters N/A Quarterly
ANSUL Fire Suppression Systems - Metro’s Headquarters (USG),3rd Floor Cafeteria
# Location System Number of
Tanks Service
Frequency
1 Front Kitchen ANSUL R-102 wet-chemical fire suppression system 2 Semi Annual
2 Back Kitchen ANSUL R-102 wet-chemical fire suppression system 2 Semi Annual