Attachment 9 Drawing FX-122.pdf
PDF 167 KB Posted
- Attached to
- HVAC Humidity Environmental Control Evaluation Federal contract opportunity
- Solicitation number
- FA671223Q0004
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 1 Combined Synopsis Solicitation.docx | DOCX document | |
| Attachment 2 Statement of Work.docx | DOCX document | |
| Attachment 4 Wage Determination No. 2015-4235 Rev. No. 22, Dated 27 Dec 2022.pdf | ||
| Attachment 6 Drawing EP-121.pdf | ||
| Attachment 8 Drawing FX-121.pdf | ||
| Attachment 12 Drawing M-223.pdf | ||
| Attachment 16 Schedule (Existing Panel Board) E-723.pdf | ||
| Attachment 3 Quote Template.docx | DOCX document | |
| Attachment 15 Schedule (Lighting Fixture - Shop Equipment Data) E-722.pdf | ||
| Attachment 19 HVAC Schedule.pdf | ||
| Attachment 11 Drawing M-222.pdf | ||
| Attachment 13 Drawing P-121.pdf | ||
| Attachment 5 Drawing A-120.pdf | ||
| Attachment 7 Drawing EP-122.pdf | ||
| Attachment 10 Drawing M-221.pdf | ||
| Attachment 14 Drawing P-122.pdf | ||
| Attachment 17 Branch Panel E-724.pdf | ||
| Attachment 18 Branch Panel E-725.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
KEY PLAN
NEW WET-PIPE SPRINKLER PROTECTION FOR LIGHT HAZARD
PROTECTION (0.1 GPM/SQ. FT. OVER THE MOST REMOTE 1,500 SQ. FT.)
WITH 5.6 K-FACTOR SPRINKLERS FOR CEILING HEIGHTS 30-FT OR LESS
NEW WET-PIPE SPRINKLER PROTECTION FOR ORDINARY HAZARD
PROTECTION (0.2 GPM/SQ. FT. OVER THE MOST REMOTE 2,500 SQ. FT)
WITH 8.0 K-FACTOR SPRINKLERS FOR CEILING HEIGHTS 30-FT OR LESS
NEW WET-PIPE SPRINKLER PROTECTION FOR ORDINARY HAZARD
PROTECTION (0.2 GPM/SQ. FT. OVER THE MOST REMOTE 2,500 SQ. FT.)
WITH 11.2 K-FACTOR SPRINKLERS FOR CEILING HEIGHTS OVER 30 FT
FIRE PROTECTION KEYED NOTES
1 1.1 2 2.1 3 3.1 4 4.1 4.11 5 5.1 6 6.1 7 7.1 8
C
C.1
C.11
D
E
3 3
METALS TECH
SHEET METAL
CORROSION
CONTROL
SMCO
STORAGE
124A
WELD LAB
METALS
STORAGE
117A
A1 A2 A3 A4 A5
B1 B2 B3 B4 B5
98 99
METALS
STORAGE
117A
HYDRAULIC DESIGN AREA: 0.2 GPM/SQ.
FT. OVER 2,500 SQ. FT. WITH 11.2 K-
FACTOR SPRINKLERS; SPRINKLERS
AND PIPE SIZES SHOWN FOR
REFERENCE ONLY TO CONFIRM THE
ADEQUACY OF THE WATER SUPPLY
2"2"
6"
6"
-1
/2
-1
/2
2-1/2"
RISER
" 2-1/2"
RISER
-1
/2
-1
/4
US Army Corps of Engineers
LOUISVILLE
1 2 3 4 5
D
B
A
C
DISTRICT
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
P
IT
T S
B U
R G
H A
IR
R
E S
E R
V E
S T
A T
IO
N
C O
N S
O L
ID
A T
E D
B U
IL
D
IN
G
R E
N O
V A
T
IO
N S
P N
J L S
S
J L S
S
J L S
S
AS-BUILT
W Q
R -1
-C
-0
FX122
B U
IL
D
IN
G
F
IR
S T
F L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
A R
E A
B
S .D
U B
IN
S .D
U B
IN
D .H
U G
H L E
Y
/1 /2
N
4'0 8' 16'SCALE: 1/8" = 1'-0"
BUILDING 417 - FIRST FLOOR SPRINKLER PLAN - AREA B
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
File details come from the government source that posted it. Updated .