Attachment 14 Drawing P-122.pdf
PDF 143 KB Posted
- Attached to
- HVAC Humidity Environmental Control Evaluation Federal contract opportunity
- Solicitation number
- FA671223Q0004
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 3 Quote Template.docx | DOCX document | |
| Attachment 15 Schedule (Lighting Fixture - Shop Equipment Data) E-722.pdf | ||
| Attachment 19 HVAC Schedule.pdf | ||
| Attachment 11 Drawing M-222.pdf | ||
| Attachment 13 Drawing P-121.pdf | ||
| Attachment 1 Combined Synopsis Solicitation.docx | DOCX document | |
| Attachment 2 Statement of Work.docx | DOCX document | |
| Attachment 4 Wage Determination No. 2015-4235 Rev. No. 22, Dated 27 Dec 2022.pdf | ||
| Attachment 6 Drawing EP-121.pdf | ||
| Attachment 8 Drawing FX-121.pdf | ||
| Attachment 9 Drawing FX-122.pdf | ||
| Attachment 12 Drawing M-223.pdf | ||
| Attachment 16 Schedule (Existing Panel Board) E-723.pdf | ||
| Attachment 5 Drawing A-120.pdf | ||
| Attachment 7 Drawing EP-122.pdf | ||
| Attachment 10 Drawing M-221.pdf | ||
| Attachment 17 Branch Panel E-724.pdf | ||
| Attachment 18 Branch Panel E-725.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6" SS
(EXIST.) (EXIST.) (EXIST.) (EXIST.)
6" SS 6" SS 6" SS
S S
S S
(E X
IS
T
(E X
IS
T
(E X
IS
T
(E X
IS
T
FS-1 FS-1
FS-2
FS-1
FS-1
FS-2
S S
S S
3" SS
S S
S S
4" SS
FD
FCO
S S
S S
S S
3" SS
3" SS
4" SS
2" SS
2" V
3" SS
2" V
2" V
V
2" V
V
2" V
PLUGPLUGPLUGPLUG
NEW TO EXIST.
INTERFACE
NEW TO EXIST.
INTERFACE
NEW TO EXIST.
INTERFACE
NEW TO EXIST.
INTERFACE
3" SS
NEW TO EXIST.
INTERFACE
2" VENT UP TO VTR
2" VENT UP TO VTR
4" SS
WF
3" VENT UP TO VTR
FS-1
FS-1
NEW TO EXIST.
INTERFACE
NEW TO EXIST.
INTERFACE
METALS
STORAGE
117A
SMCO
STORAGE
124A
WELD LAB
CORROSION
CONTROL
METALS TECH
SHEET METAL
C
C.1
C.11
D
E
/1 P-121 /1 P-121
B
KEY PLAN
US Army Corps of Engineers
LOUISVILLE
1 2 3 4 5
D
B
A
C
DISTRICT
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
P
IT
T S
B U
R G
H A
IR
R
E S
E R
V E
S T
A T
IO
N
C O
N S
O L
ID
A T
E D
B U
IL
D
IN
G
R E
N O
V A
T
IO
N S
P N
J L S
S
J L S
S
J L S
S
AS-BUILT
W Q
R -1
-C
-0
P-122
B U
IL
D
IN
G
P L U
M B
IN
G
D W
V F
IR
S
T F
L O
O R
P L A
N
A R
E A
B
V A
M A
D O
R
V A
M A
D O
R
K M
IL
L
E R
-1 -2
4'0 8' 16'
GRAPHIC
N
SCALE: 1/8" = 1'-0"
BUILDING 417 - PLUMBING DWV FIRST FLOOR PLAN - AREA B
PLUMBING GENERAL NOTES
1 FIELD VERIFY LOCATION AND INVERTS OF SITE
UTILITIES AND INTERIOR BUILDING SERVICES PRIOR
TO CONSTRUCTION / INSTALLATION
2 WHERE PLUMBING PIPES MUST PENETRATE
THROUGH STRUCTURAL BEAMS, SEE STRUCTURAL
DRAWING DEATILS AND SCHEDULES. BEAM
OPENING DETAILS AND SCHEDULES CAN BE FOUND
ON DRAWING S-532
3 COORDINATE ALL ASPECTS OF WORK WITH OTHER
TRADES PRIOR TO AND DURING CONSTRUCTION /
INSTALLATION
4 UNDERGROUND SANITARY SEWER PIPING BELOW
FLOOR SLAB AND EXTENDING THROUGH FLOOR
SHALL BE 2" MINIMUM
5 PROVIDE CLEANOUT IN ACCESSIBLE LOCATION AT
THE BASE OF ALL PLUMBING RISERS
6 SEE PROJECT PLUMBING NOTES ON DRAWING P-001
FOR ADDITIONAL INFORMATION