Attachment 7 Drawing EP-122.pdf
PDF 241 KB Posted
- Attached to
- HVAC Humidity Environmental Control Evaluation Federal contract opportunity
- Solicitation number
- FA671223Q0004
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 11 Drawing M-222.pdf | ||
| Attachment 13 Drawing P-121.pdf | ||
| Attachment 1 Combined Synopsis Solicitation.docx | DOCX document | |
| Attachment 2 Statement of Work.docx | DOCX document | |
| Attachment 4 Wage Determination No. 2015-4235 Rev. No. 22, Dated 27 Dec 2022.pdf | ||
| Attachment 6 Drawing EP-121.pdf | ||
| Attachment 8 Drawing FX-121.pdf | ||
| Attachment 9 Drawing FX-122.pdf | ||
| Attachment 12 Drawing M-223.pdf | ||
| Attachment 16 Schedule (Existing Panel Board) E-723.pdf | ||
| Attachment 5 Drawing A-120.pdf | ||
| Attachment 10 Drawing M-221.pdf | ||
| Attachment 14 Drawing P-122.pdf | ||
| Attachment 17 Branch Panel E-724.pdf | ||
| Attachment 18 Branch Panel E-725.pdf | ||
| Attachment 3 Quote Template.docx | DOCX document | |
| Attachment 15 Schedule (Lighting Fixture - Shop Equipment Data) E-722.pdf | ||
| Attachment 19 HVAC Schedule.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
m mmm m m
J
J J J
F
F
F m m
B
KEY PLAN
1 1.1 2 2.1 3 3.1 4 4.1 4.11 5 5.1 6 6.1 7 7.1 8
C
C.1
C.11
D
E
METALS
STORAGE
117A
SMCO
STORAGE
124A
CORROSION
CONTROL
WELD LAB
METALS
TECH
118 SHEET
METAL
SEE SHEET: EP121SEE SHEET: EP121
20 12
MTDP
MTPPA
- 7,9,11SMDP
- 23,25,27SMPP- 17,19,21SMPP
60 61
MTPPB
- 1,3,5MTDP
- 25,27,29MTDP
- 31,33,35MTDP
- 26,28,30MTDP
- 32,34,36MTPPA
- 1,3,5MTPPA
- 25,27MTPPA
- 29,31,33MTPPA
- 37,39,41MTPPA
- 8,10,12MTPPA
- 28MTPPA
- 1,3MTPPB
- 5,7MTPPB
- 9,11,13MTPPB
- 15,17MTPPB
WH
WH
- 14417MDP
- 15417MDP
PF
PF
PF
- 19,21,23SMDP
- 8,10,12MTDP
#10 AWG
#10 AWG
#10 AWG
#4 AWG
214 215
12"x4"
24"x4"
12"x4"
"x
BOCT: 29' - 10"
BOCT: 12' - 0"
BOCT: 12' - 0"
BOCT: 12' - 0"
"x
"x
"x
12"x4"1
"x
SMCO
16 16
28 28 28
- 12,14SMPP
- 1,3,5SMCO
- 2,4,6SMCO
- 7,9,11SMCO
- 8,10,12SMCO
- 13,15,17SMCO
- 14,16,18SMCO
- 19,21,23SMCO
- 20,22,24SMCO
- 16SMPP13,15,17
19,21,23
UH
- 36SMPP
UH
- 25MTPPB
- 33MTPPB
- 13MTPPA
- 24MTPPB
- 26,28MTPPB
- 15,17MTPPA
- 14,16,18MTPPA
- 32MTPPB
218 218
- 34MTPPB
- 30MTPPA
T3
200A TRANSFORMER
DISCONNECT SWITCH
#3 AWG
VERIFY POWER
CONNECTION
LOCATION WITH
EQUIPMENT
PROVIDED (TYP OF 4).
T3
- 25417PP2
- 4417PP2
- 2417PP2
- 6417PP2
BOCT: 12' - 0"
BOCT: 12' - 0"
B O
C T
B O
C T
B O
C T
: 1
(TYP)
(TYP)
222 (TYP)
(TYP)
(TYP)
(TYP)
- 29,31MTPPB
(TYP)
(TYP)
B O
C T
: 1
B
O C
T
B O
C T
B O
C T
B O
C T
: 1
B O
C T
: 1
(TYP)
B O
C T
: 1
B O
C T
: 1
MTDP-14,16,18
1. SEE SHEET E-001 FOR LEGEND & GENERAL NOTES.
2. SEE SHEET E-501 FOR CONTROL OF SWITCHED
DEVICES.
3. SEE SHOP EQUIPMENT SCHEDULE ON SHEET E-722.
US Army Corps of Engineers
LOUISVILLE
1 2 3 4 5
D
B
A
C
DISTRICT
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
P
IT
T S
B U
R G
H A
IR
R
E S
E R
V E
S T
A T
IO
N
C O
N S
O L
ID
A T
E D
B U
IL
D
IN
G
R E
N O
V A
T
IO
N S
P N
J L S
S
J L S
S
J L S
S
AS-BUILT
W Q
R -1
-C
-0
EP122
B U
IL
D
IN
G
F
IR
S T
F L O
O R
P O
W E
R P
L A
N
A R
E A
B
K B
A N
O V
IC
R B
L O
C H
E R
K H
A R
R
IS
-1 -2
N
SCALE: 1/8" = 1'-0"
BUILDING 417 - FIRST FLOOR POWER PLAN AREA B
4'0 8' 16'
GENERAL NOTES
KEYED NOTES
214 WALL MOUNTED RECEPTACLES IN THIS ROOM INSTALLED AT 44" AFF.
215 UTILIZE CABLE TRAY WITH TRAY CABLE (SIZED AS INDICATED ON SHOP
EQUIPMENT DATA SCHEDULE, SHEET E-722). TRANSITION TO CONDUIT
FOR DROPS OUT OF TRAY. PROVIDE FLOOR MOUNTED STRUT
STANCHION TO MOUNT DEVICE AT 48" AFF.
217 4"X6" OUTLET BOX MTD. 48" AFF WITH DEDICATED 20A, 120 VAC CIRCUIT
FOR THE FUTURE ACCESS CONTROL PANEL TO BE PROVIDED BY
OTHERS.
218 4"X6" OUTLET BOX MTD 108" AFF ON THE SECURE SIDE OF THE ENTRY
DOOR. OUTLET BOX SHALL INCLUDE A DEDICATED 20A, 120 VAC CIRCUIT
FOR THE FUTURE KEYPAD/CARD READER ENTRY SYSTEM TO BE
PROVIDED BY OTHERS.
220 INSTALL FAN CONTROLLER PROVIDED WITH FAN. PROVIDE 3/4"C - 5#12
FROM FAN TO CONTROLLER LOCATION.
221 COORDINATE CABLE TRAY FLOOR SUPPORT LOCATION WITH EQUIPMENT
LAYOUT AND INSTALLATION. VERIFY LOCATIONS AND TRAY MOUNTING
HEIGHT WITH USERS. SEE TRAY SUPPORT DETAIL A3 ON SHEET S-523.
222 PROVIDE WALL SUPPORT IN ACCORDANCE WITH TRAY MANUFACTURER'S
RECOMMENDATIONS. SPACE SUPPORT TO COMPLY WITH LOADING
REQUIREMENTS OF TRAY PROVIDED.
223 PROVIDE FLOOR MOUNTED STRUT STANCHION FOR DEVICE MOUNTED AT
48" AFF. COORDINATE LOCATIONS WITH EQUIPMENT INSTALLATION.
REVISED
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D A
S -B
U
IL
T
/2
/2
File details come from the government source that posted it. Updated .