Attachment 13 Drawing P-121.pdf
PDF 193 KB Posted
- Attached to
- HVAC Humidity Environmental Control Evaluation Federal contract opportunity
- Solicitation number
- FA671223Q0004
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 11 Drawing M-222.pdf | ||
| Attachment 1 Combined Synopsis Solicitation.docx | DOCX document | |
| Attachment 2 Statement of Work.docx | DOCX document | |
| Attachment 4 Wage Determination No. 2015-4235 Rev. No. 22, Dated 27 Dec 2022.pdf | ||
| Attachment 6 Drawing EP-121.pdf | ||
| Attachment 8 Drawing FX-121.pdf | ||
| Attachment 9 Drawing FX-122.pdf | ||
| Attachment 12 Drawing M-223.pdf | ||
| Attachment 16 Schedule (Existing Panel Board) E-723.pdf | ||
| Attachment 5 Drawing A-120.pdf | ||
| Attachment 7 Drawing EP-122.pdf | ||
| Attachment 10 Drawing M-221.pdf | ||
| Attachment 14 Drawing P-122.pdf | ||
| Attachment 17 Branch Panel E-724.pdf | ||
| Attachment 18 Branch Panel E-725.pdf | ||
| Attachment 3 Quote Template.docx | DOCX document | |
| Attachment 15 Schedule (Lighting Fixture - Shop Equipment Data) E-722.pdf | ||
| Attachment 19 HVAC Schedule.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R E
F
S S
V
2" V
3" SS
4" SS
(EXIST.)
LAV-2
FD
SH-3
LAV-1
LAV-3
FD
FD
WC-2
WC-1
FD
MS
FD
FCO
SK
EWC
FCO
FCO
FCO
2"VTR
NEW TO EXIST, INTERFACE
NEW TO EXIST INTERFACE
3" SS
(EXIST.)
WC-2
CAP
WF
WFWF
EWS
SH-1
SH-2
FD
UR-2
3" SS
FFD
4" SS
4" SS
4" SS
(EXIST.)
3" SS
3" SS 3" SS
S S
V
2" SS
2" V
/2
V
1 1/2" V
2" V
3"VTR
2" V
FD (EXIST.)
FS-1
FCO
FCO
1 1/2" V
FD (EXIST.)
FCO (EXIST.)
S S
(E X
IS
T
3" SS
4" SS
UP TO 3"VTR
VEST
115A
JAN
ELEC
COMM
CLEAN UP
TLT
113A
COMPOSITE
SHOP
SINK/SHWR
LOCKER/TLT
114A
CORRIDOR
SMCO OFFICES
MXMF FLT
CHIEF
SMCO OFFICE
ART OFFICE
METALS TECH
SMCO TOOL
ROOM
CORRIDOR
CORRIDOR
MECHANICAL
M01
SHEET METAL
BREAK &
TRAINING
ROOM
VEST
113B
LOCKER
113C
SINK/SHWR
3" SS
3" SS 3" SS
3" SS ABOVE CEILING,
SERVING MEZZANINE
3" SS ABOVE CEILING,
SERVING MEZZANINE
3" SS ABOVE CEILING,
SERVING MEZZANINE
FD
(Mezz.)
FD
(Mezz.)
FD
(Mezz.)
2 2.1 3 3.1 4 4.1 4.11 5 5.1 6 6.1 7
A
A.1
B
B.1
B.11
USB-2
FD
FD
FD
FCO
3" SS 3
S S
3" SS
2" V
2" V
2" V
3" STACK VENT UP TO 3"
VTR AND SAN STACK DN
3" SS
3" SS
CLEANOUT
PLUG
2" V
/1 P-122 /1 P-122
V
S S
2" VTR
FD
1 1/2" V
A
KEY PLAN
US Army Corps of Engineers
LOUISVILLE
1 2 3 4 5
D
B
A
C
DISTRICT
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
P
IT
T S
B U
R G
H A
IR
R
E S
E R
V E
S T
A T
IO
N
C O
N S
O L
ID
A T
E D
B U
IL
D
IN
G
R E
N O
V A
T
IO
N S
P N
J L S
S
J L S
S
J L S
S
AS-BUILT
W Q
R -1
-C
-0
P-121
B U
IL
D
IN
G
P L U
M B
IN
G
D W
V F
IR
S
T F
L O
O R
P L A
N
A R
E A
A
V A
M A
D O
R
V A
M A
D O
R
K M
IL
L
E R
-1 -2
SCALE: 1/8" = 1'-0"
BUILDING 417 - PLUMBING DWV FIRST FLOOR PLAN - AREA A
4'0 8' 16'
GRAPHIC
N
PLUMBING GENERAL NOTES
1 FIELD VERIFY LOCATION AND INVERTS OF SITE
UTILITIES AND INTERIOR BUILDING SERVICES PRIOR
TO CONSTRUCTION / INSTALLATION
2 WHERE PLUMBING PIPES MUST PENETRATE
THROUGH STRUCTURAL BEAMS, SEE STRUCTURAL
DRAWING DEATILS AND SCHEDULES. BEAM
OPENING DETAILS AND SCHEDULES CAN BE FOUND
ON DRAWING S-532
3 COORDINATE ALL ASPECTS OF WORK WITH OTHER
TRADES PRIOR TO AND DURING CONSTRUCTION /
INSTALLATION
4 UNDERGROUND SANITARY SEWER PIPING BELOW
FLOOR SLAB AND EXTENDING THROUGH FLOOR
SHALL BE 2" MINIMUM
5 PROVIDE CLEANOUT IN ACCESSIBLE LOCATION AT
THE BASE OF ALL PLUMBING RISERS
6 SEE PROJECT PLUMBING NOTES ON DRAWING P-001
FOR ADDITIONAL INFORMATION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
File details come from the government source that posted it. Updated .