Attachment 12 Drawing M-223.pdf
PDF 166 KB Posted
- Attached to
- HVAC Humidity Environmental Control Evaluation Federal contract opportunity
- Solicitation number
- FA671223Q0004
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 3 Quote Template.docx | DOCX document | |
| Attachment 15 Schedule (Lighting Fixture - Shop Equipment Data) E-722.pdf | ||
| Attachment 19 HVAC Schedule.pdf | ||
| Attachment 11 Drawing M-222.pdf | ||
| Attachment 13 Drawing P-121.pdf | ||
| Attachment 1 Combined Synopsis Solicitation.docx | DOCX document | |
| Attachment 2 Statement of Work.docx | DOCX document | |
| Attachment 4 Wage Determination No. 2015-4235 Rev. No. 22, Dated 27 Dec 2022.pdf | ||
| Attachment 6 Drawing EP-121.pdf | ||
| Attachment 8 Drawing FX-121.pdf | ||
| Attachment 9 Drawing FX-122.pdf | ||
| Attachment 16 Schedule (Existing Panel Board) E-723.pdf | ||
| Attachment 5 Drawing A-120.pdf | ||
| Attachment 7 Drawing EP-122.pdf | ||
| Attachment 10 Drawing M-221.pdf | ||
| Attachment 14 Drawing P-122.pdf | ||
| Attachment 17 Branch Panel E-724.pdf | ||
| Attachment 18 Branch Panel E-725.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HT
A
B
KEY PLAN
70"X50"
18"Ø
24"Ø
30"X24"
12"Ø
"Ø
"X
180"X96"180"X96"
2 2.1 3 3.1 4 4.1 4.11 5
A
A.1
B
B.1
B.11
C
C.1
C.11
D
E
PF
PF
PF
PF
D-400 D-400 D-400
D-400 D-400
12"Ø
12"Ø
12"Ø
12"Ø
"Ø
"Ø
14"Ø 14"Ø
Z-1000 Z-1000
M-305
AHU
AHU
AHU
HV
HV
HV
112 112 112
113113113
"X
O
/A
"X
E /A 3 "X
E /A
70"X50" E/A
24"Ø R/A
70"X50" O/A
"X
O
/A
US Army Corps of Engineers
LOUISVILLE
1 2 3 4 5
D
B
A
C
DISTRICT
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
P
IT
T S
B U
R G
H A
IR
R
E S
E R
V E
S T
A T
IO
N
C O
N S
O L
ID
A T
E D
B U
IL
D
IN
G
R E
N O
V A
T
IO
N S
P N
J L S
S
J L S
S
J L S
S
AS-BUILT
W Q
R -1
-C
-0
M-223
B U
I L D
IN
G
H V
A C
M E
Z Z
A N
IN
E
P L A
N
O V
E R
A L L
V A
M A
D O
R
V A
M A
D O
R
K M
IL
L
E R
-1 -2
N
4'0 8' 16'SCALE: 1/8" = 1'-0"
BUILDING 417 - HVAC MEZZANINE PLAN- OVERALL
KEY NOTES
101 WALL MOUNTED DDC TEMPERATURE SENSOR.
102 WALL MOUNTED DDC HUMIDITY SENSOR.
104 PROVIDE A 36" DEEP (MIN.) PLENUM ON BACKSIDE
OF LOUVER. SEE ARCHITECTURAL DRAWINGS FOR
SIZE AND TYPE.
105 70X50 GRAVITY BACKDRAFT DAMPER.
112 CONCRETE HOUSEKEEPING PAD
113 DUCTWORK ROUTED DOWN TO FIRST FLOOR.
114 DUCTWORK CONTINUED ON FIRST FLOOR.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
File details come from the government source that posted it. Updated .