Attachment 11 Drawing M-222.pdf
PDF 143 KB Posted
- Attached to
- HVAC Humidity Environmental Control Evaluation Federal contract opportunity
- Solicitation number
- FA671223Q0004
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 13 Drawing P-121.pdf | ||
| Attachment 5 Drawing A-120.pdf | ||
| Attachment 7 Drawing EP-122.pdf | ||
| Attachment 10 Drawing M-221.pdf | ||
| Attachment 14 Drawing P-122.pdf | ||
| Attachment 17 Branch Panel E-724.pdf | ||
| Attachment 18 Branch Panel E-725.pdf | ||
| Attachment 3 Quote Template.docx | DOCX document | |
| Attachment 15 Schedule (Lighting Fixture - Shop Equipment Data) E-722.pdf | ||
| Attachment 19 HVAC Schedule.pdf | ||
| Attachment 1 Combined Synopsis Solicitation.docx | DOCX document | |
| Attachment 2 Statement of Work.docx | DOCX document | |
| Attachment 4 Wage Determination No. 2015-4235 Rev. No. 22, Dated 27 Dec 2022.pdf | ||
| Attachment 6 Drawing EP-121.pdf | ||
| Attachment 8 Drawing FX-121.pdf | ||
| Attachment 9 Drawing FX-122.pdf | ||
| Attachment 12 Drawing M-223.pdf | ||
| Attachment 16 Schedule (Existing Panel Board) E-723.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
S
S
S
METALS
STORAGE
117A
SMCO
STORAGE
124A
ELEC
117A
WELD LAB
CORROSION
CONTROL
"Ø
24"X15"
C
C.1
C.11
D
E
"Ø
"Ø
"X
M-305
"Ø R
/A
36"Ø R/A 30"Ø R/A
W-700
W-700
W-700
W-700
W-700
AA
AA
AA
X-1100X-1100
X-1100
X-1100
X-1100
X-1100
Y-980
Y-1100
Y-980
Y-980
Y-980
CC CC CC CC
40"Ø R/A30"Ø R/A
36"Ø S/A
"Ø R
/A
"Ø
R /A
"Ø R
/A
BB
BB
BB
UH
UH
"Ø S
/A
"Ø
S /A
"Ø S
/A
"Ø
S /A
20"Ø S/A
18"Ø S/A
20"Ø S/A
B
KEY PLAN
US Army Corps of Engineers
LOUISVILLE
1 2 3 4 5
D
B
A
C
DISTRICT
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
P
IT
T S
B U
R G
H A
IR
R
E S
E R
V E
S T
A T
IO
N
C O
N S
O L
ID
A T
E D
B U
IL
D
IN
G
R E
N O
V A
T
IO
N S
P N
J L S
S
J L S
S
J L S
S
AS-BUILT
W Q
R -1
-C
-0
M-222
B U
IL
D
IN
G
F
IR
S T
F L O
O R
H V
A C
P L
A N
A
R E
A B
V A
M A
D O
R
V A
M A
D O
R
K M
IL
L
E R
-1 -2
SCALE: 1/8" = 1'-0"
BUILDING 417 - FIRST FLOOR HVAC PLAN - AREA B
N
4'0 8' 16'
KEY NOTES
103 EMERGENCY SHUT DOWN SWITCH. SEE SHEET
M-423 FOR DETAILS.
106 RISE ABOVE OVERHEAD DOOR.
109 DUCTWORK ROUTED UP TO MEZZANINE LEVEL.
110 DUCTWORK CONTINUED ON MEZZANINE LEVEL
111 PAINT BOOTH AND BLAST BOOTH EQUIPMENT AND
INSTALLATION BY OTHERS.
MATCHLINE MATCHLINE
M A
R K
D E
S C
R
IP
T
IO
N D
A
E
File details come from the government source that posted it. Updated .