CCT.

NO.S

IZ

E

B R

K R

P O

L E

KVA DESCRIPTION

LOAD

KVA P

H

A S

E

S

IZ

E B

R K

R

P O

L E

NO.

CCT.

DESCRIPTION

LOAD

A

B

C

C

B

A

C

B

A

C

B

A

C

B

A

C

B

A

C

B

A

1 RECPT HANGER N WALL RECPT WOMEN'S REST ROOM20 - - 1 20

201--20 HANGER DROP LIGHTSRECPT HANGER NOSE AREA1

201--20 LIGHTING CONTROL PANELRECPT HANGER NOSE AREA1

201--20 RECPT HANGER NE WALLRECPT HANGER N. WALL1

201--20 RECPT HANGER NE WALLHVAC SHUT DOWN/DUCT DET1

201--20 SPAREWEST HOSE REEL1

201--20 DOOR OPERATORNORTH HOSE REEL1

201--20 RECPT HANERLIGHT REELS1

201--20 EF-1EXIT LIGHTS1

201--20 P-3P-21

201--20 INSTANT AIR DRYERRECPT MEN'S REST ROOM1

201--20 ADVANTOR SEC PANELMECH RM HOT WATER PUMP1

201--20 FA EXTENDER PANELFIRE SYSTEM COMPRESSOR1

201--

TO PANEL D-RTH

GUTTER DE-ICING1

201-- TO PANEL D-RTH

201--

TO PANEL D-RTH

GUTTER DE-ICING1

201-- P-1

201--

VESS LDB COMMUNICATIONS

COMPRESSED AIR DRYER1

201-- SPARE

201--20 SPARESPARE1

201--20 SPARESPARE1

W

EXISTING PANELBOARD SCHEDULE

BPANEL: PHV 43120/208 MOUNTING100A MCBMAIN

KAIC

2019 B

CCT.

NO.S

IZ

E

B R

K R

P O

L E

KVA DESCRIPTION

LOAD

KVA P

H

A S

E

S

IZ

E B

R K

R

P O

L E

NO.

CCT.

DESCRIPTION

LOAD

A

B

A

B

A

B

A

B

A

OFFICE AREA LIGHTING BATHROOM LIGHTS1 20 - - 1 20

1--201 BACK FLOOD LIGHTSFRONT FLOOD LIGHTS

1--201 SPARESIDE FLOOD LIGHTS

1--201 MECH RM & EM HANGER LTSHANGER NIGHT LIGHTS & E. OH DOOR LTS

1--201 SPACESPACE

1--201 SPACESPACE

1--201 SPACESPACE

1--201 SPACESPACE

1--201 SPACESPACE

1--201 SPACESPACE

W

EXISTING PANELBOARD SCHEDULE

CPANEL: PHV 43480/277 MOUNTING100A MCBMAIN

KAIC

CCT.

NO.S

IZ

E

B R

K R

P O

L E

KVA DESCRIPTION

LOAD

KVA P

H

A S

E

S

IZ

E B

R K

R

P O

L E

NO.

CCT.

DESCRIPTION

LOAD

A

B

C

C

B

A

C

B

A

C

B

A

153--15 SPARESPARE3

153--15 P-1 (1 HP)BRIDGE CRANE (OVERHEAD)3

153--15 CRANE TAIL DOORSPARE3

201-- SPACE

201--30 SPACEEF-2 (1/2 HP)3

201-- SPACE

W

EXISTING PANELBOARD SCHEDULE

D-1PANEL: PHV 43480Y/277 MOUNTING225A MCBMAIN

KAIC

CCT.

NO.S

IZ

E

B R

K R

P O

L E

KVA DESCRIPTION

LOAD

KVA P

H

A S

E

S

IZ

E B

R K

R

P O

L E

NO.

CCT.

DESCRIPTION

LOAD

A

B

C

C

B

A

C

B

A

C

B

A

153--30 NEW TWIN AIR COMPRESSORHWB-1 (1-1/2 HP)3

153--15 EF-2 STARTERINST. AIR COMPRESSOR3

153--15 10 HP COMPRESSORDOOR OPERATOR (1/2 HP) TAIL3

153--30 SPARESPARE3

W

EXISTING PANELBOARD SCHEDULE

B-2PANEL: PHV 43480/277 MOUNTING225A MCBMAIN

KAIC

CCT.

NO.S

IZ

E

B R

K R

P O

L E

KVA DESCRIPTION

LOAD

KVA P

H

A S

E

S

IZ

E B

R K

R

P O

L E

NO.

CCT.

DESCRIPTION

LOAD

A

B

C

C

B

A

C

B

A

C

B

A

1 CIRCULATING PUMP MECH ROOM LIGHTS-NEW ADDITION20 - - 1 20

201--20 RECPT-NEW ADDITIONSPARE TO PANEL B1

--20

HEATER-NEW ADDITION

RECEPT WATER COOLER, JANITOR1

30 RECPT DRYER, JANITOR CLOSET RM 2082

201--20 FOAM SUPPRESSION CONTROL PNLHOT WATER BLOWER1

201--20 TEMP SENSOR CONTROL PANELSNOW MELT BLOWER1

201--20 BITI RM 7 CAB 1SPARE1

201--20 SPARESPARE1

201--20 SPARESPARE1

25 SPARESPARE2

W

EXISTING PANELBOARD SCHEDULE

FPANEL: PHV 43120/208 MOUNTING100A MCBMAIN

KAIC

201ISOLATION VALVE

CCT.

NO.S

IZ

E

B R

K R

P O

L E

KVA DESCRIPTION

LOAD

KVA P

H

A S

E

S

IZ

E B

R K

R

P O

L E

NO.

CCT.

DESCRIPTION

LOAD

A

B

C

C

B

A

C

B

A

C

B

A

C

B

A

C

B

A

C

B

A

AC-2 AND CU-2

20 - - 2 20

--201

201--20 BAC CABINET1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

201--20 SPARE1

--201

303--20 SPD1

--201

W

EXISTING PANELBOARD SCHEDULE

GPANEL: PHV 43120/208 MOUNTING100A MCBMAIN

KAIC

FIRE ALARM CTRL PANEL

FENWAL PANEL

SPARE

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

KVA

KVA

KVA

KVA

TOTAL =

C PH =

B PH =

A PH = -

KVA

KVA

KVA

KVA

TOTAL =

C PH =

B PH =

A PH = -

KVA

KVA

KVA

KVA

TOTAL =

C PH =

B PH =

A PH = -

KVA

KVA

KVA

KVA

TOTAL =

C PH =

B PH =

A PH = -

KVA

KVA

KVA

KVA

TOTAL =

C PH =

B PH =

A PH = -

KVA

KVA

KVA

KVA

TOTAL =

C PH =

B PH =

A PH = -

CCT.

NO.S

IZ

E

B R

K R

P O

L E

KVA DESCRIPTION

LOAD

KVA P

H

A S

E

S

IZ

E B

R K

R

P O

L E

NO.

CCT.

DESCRIPTION

LOAD

A

B

C

C

B

A

C

B

A

C

B

A

C

B

A

C

B

A

1 AC-1 (1/2 HP)20 - - 1 20HV-1

1 20 REC OFFICE A (4A) OFFICE B (4B) RECPTS STORAGE 2C 201--

1 20 REC OFFICE A (4A) OFFICE B (4B) REC HANGER NOSE LFT 201--

1 20 WATER COOLER BRK RM, OFF. B RECEPTACLES 201--

1 20 REC HANGER COLUMN LINE 4B REC HANGER WEST WALL 201--

1 20 REC HANGER COLUMN LINE 3B REC HANGER WEST WALL 201--

1 20 REC STOCK RM SOUTH WALL REC HANGER WEST WALL 201--

1 20

REC STOCK RM, NOSE HANGER

DOOR OPERATOR 201--

1 20

REC COMPUTER RM, STOCK RM

DOOR OPERATOR 201--

1 20 - REC HALL, COMPUTER RM FAB 201--

1 20 SPRINKLER CP, FACP BLANK 201--

SPARE 201--

3 20 SURGE SUPPRESSOR RECEPTACLES HANGER 201--

REC BRK RM N & W WALLS RM 5 201--

1 20 REC MEZZAININE BLANK 201--

1 20 REC MEZZAININE --

1 20 LTS HANGER UNDER MEZZANINE MAIN 603--

1 20 BLANK --

W

EXISTING PANELBOARD SCHEDULE

APANEL: PHV 43120/208 MOUNTING100A MCBMAIN

KAIC

CCT.

NO.S

IZ

E

B R

K R

P O

L E

KVA DESCRIPTION

LOAD

KVA P

H

A S

E

S

IZ

E B

R K

R

P O

L E

NO.

CCT.

DESCRIPTION

LOAD

A

B

C

C

B

A

C

B

A

C

B

A

1 REFRIG S. WALL RM 5 HOT WATER UNDER SINK RM520 - - 1 20

201--20 SPAREGFCI REC E & S WALL CNTR RM 51

201--20 GRINDER PUMP RECPTGFCI REC COUNTER S WALL RM 51

201-- EXHAUST FAN

201--20 RECPTS COMPUTER ROOMHVAC RT UNIT AHU-1 ROOF MTD1

201-- DUCT DETECTOR IN BREAK ROOM

201-- SPARE

201--

SPARE

RANGE ROOM 51

201--20 SPARESIEMENS CONTROL PANEL1

201--20 SPARESPARE1

201--20 SPARESPARE1

201--20 SPARESPARE1

W

EXISTING PANELBOARD SCHEDULE

EPANEL: PHV 43120/208 MOUNTING100A MCBMAIN

KAIC

PANEL TO BE REMOVED

PANEL TO BE REMOVED

KVA

KVA

KVA

KVA

TOTAL =

C PH =

B PH =

A PH = -

KVA

KVA

KVA

KVA

TOTAL =

C PH =

B PH =

A PH = -

CONTRACTOR SHALL REVISE LOADS AND

UPDATE EXISTING PANEL SCHEDULES

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

VESS POWER

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE SPARE

SPARE SPARE

SPARE SPARE

SPARE SPARE

SPARE SPARE

SPARE SPARE

SPARE SPARE

SPARE SPARE

SPARE SPARE

SPARE SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

D-2

LIGHTS NEW ADDITION

RECEP NEW ADDITION

HEATER

ATC PANEL

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

US Army Corps of Engineers

LOUISVILLE

1 2 3 4 5

D

B

A

C

DISTRICT

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

P

IT

T S

B U

R G

H A

IR

R

E S

E R

V E

S T

A T

IO

N

C O

N S

O L

ID

A T

E D

B U

IL

D

IN

G

R E

N O

V A

T

IO

N S

P N

J L S

S

J L S

S

J L S

S

AS-BUILT

W Q

R -1

-C

-0

E-723

B U

IL

D

IN

G

E X

IS

T

IN

G

E L E

C T

R

IC

A L

S C

H E

D U

L E

S

K B

A N

O V

IC

R B

L O

C H

E R

K H

A R

R

IS

-1 -2

OUTSIDE LIGHT

MECHANICAL ROOM RECEP

MECHANICAL ROOM RECEP

REVISED

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D A

S -B

U

IL

T

/2

/2

File details come from the government source that posted it. Updated .