Attachment 7 - Furniture Scope of Work and Specifcation.pdf

PDF 295 KB Posted

Attached to
HVAC Repair Space Optimization & Renovation PNSY-B43 Federal contract opportunity
Solicitation number
N4008520B2557
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document includes a scope of work and specifications for furniture required as part of an HVAC repair, space optimization, and renovation project for the Portsmouth Naval Shipyard in Kittery, Maine. The scope of work requires furnishing a variety of items including thirteen workstations, three break room tables, twenty-four mobile stackable chairs, sixteen tall perimeter seats, thirteen multi-purpose office chairs, fourteen mobile stackable side chairs, and five side tables. It specifies dimensions, materials, and features for each item. The related federal contract opportunity is solicitation number N4008520B2557 for the HVAC Repair Space Optimization & Renovation PNSY-B43 project being conducted by the Department of the Navy Naval Facilities Engineering Command.

View the file

Other files for this federal contract opportunity

Other files attached to HVAC Repair Space Optimization & Renovation PNSY-B43, newest first.
File Type Posted
Attachment 6 - Draft Internal Service Requirement List.xlsx XLSX spreadsheet
Attachment 2 - Specifications.pdf PDF
N4008520B2557.pdf PDF
Attachment 4 - Drawings.pdf PDF
Attachment 1 - Bid Form.pdf PDF
encl a - Scope of Work.pdf PDF
Attachment 9 - NAVFAC MIDLANT PWD-Maine - ICS Standard.pdf PDF
Attachment 5 - Draft eOMSI Workbook.xlsx XLSX spreadsheet
Attachment 8 - Project Laydown and Construction Barrier Drawings.pdf PDF
Attachment 3 - Submittal Register.xls XLS spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 7

MM OH - HVAC REPAIR SPACE OPTIMIZATION & RENOVATION PNSY-43

FURNITURE SCOPE OF WORK AND SPECIFICATION

General

1. Site visit is required for dimension verification and final layout.

2. Contractor required to remove and dispose of old furniture.

3. Installation/assembly/set-up of all materials to be included.

4. All colors, finishes and/or materials to be selected by

NAVFAC from vendor’s standard color options through samples and submittals.

5. Workstations must be clean and in useable/working condition when installation is complete.

6. Items such as desks, workstations and systems furniture must include all necessary components to be structurally sound and must not be attached to the wall unless specified to be wall mounted in the contract documents.

Furniture for Workstations:

1. Typical of (13). Exact dimensions must be verified for best fit of each location.

2. Work Surface will be panel supported/cantilevered surfaces, consisting of one rectangular surface. Size to be (6’L x 2'W) at a minimum and stretched to fit the space where applicable. At a minimum, work surface to be of a high pressure wood laminate material with cable pass through.

3. Pencil drawer mounted under work surface.

4. One (4’L x 2’W) rectangular surface. At a minimum, to be of a high pressure wood laminate material with cable pass through.

5. Exceeds BIFMA Test criteria.

6. No visible crossbars

7. One (1) open shelf, approximately 36” wide (min. 36” max.

42”), secured to the wall panel.

8. Task lighting to consist of one (1) LED light strip, per overhead bin or shelf. Lighting and cords shall be secured to the underside of said shelf by heavy duty magnet, sturdy clip and/or cord tracks.

9. One (1) D/D/F with one pencil tray insert (non-work surface supported) and one (1) F/F pedestals. One (1) pedestal to have casters and padded top. Pedestal height should maximized the space under the work surface.

10. All doors and drawers to be locking and keyed alike within each workstation.

Electrical/Data/Voice for Workstations:

1. Workstation shall maintain access to wall outlets for plugging in computers and monitors.

2. Workstation will have one (1) cat6 data cable (blue) and one (1) white cat6 voice cable. Data and voice cables should be terminated at the wall jack and whips/cables to each station. Whips/cables should have minimum 3’ of slack at each station.

Break/Lunch Room 110:

1. Tables:

a. Three (3) tables dimension 3’x7’ rectangle. Sized to fit at least 8 people.

b. Material to be a high pressure wood laminate material.

2. Mobile Stackable Chairs:

a. Quantity (24), nesting/stackable chairs with arms and caster feet appropriate for the specified floor.

b. Chairs to have hard vinyl seat and back and metal frames.

3. Tall seats for perimeter seating:

a. Quantity (16)

b. Seats shall be sized at the height required to sit at the perimeter counter installed under this project.

c. Chairs to have hard vinyl seat and back with metal frames.

Multi-Purpose Office Chairs:

1. Quantity thirteen (13) multi-purpose chairs. Refer to scope of work for quantities associated with each option.

2. Chairs to have fabric seat and back and metal frames. Seat and back to be cushioned.

3. Chairs to have 5-star based caster feet appropriate for the specified floor.

4. Chairs to have adjustable arm-rests, adjustable back, and pneumatic seat height adjustment. Arm-rests to be cushioned.

5. Chair to be full swivel type with adjustable/locking tilt-back control.

6. Colors and finish to be selected by customer from vendor’s standard options.

Mobile Stackable Side Chairs:

1. Quantity fourteen (14) stackable chairs with arms and caster feet appropriate for the specified floor.

2. Chairs to have fabric seat and back and metal frames. Seat and back to be cushioned.

Side Tables:

1. Quantity four (4) small and one (1) large

2. Small tables to be 2’ x 3’.

3. Large table to be 3’ x 6’.

4. At a minimum, work surface to be of a high pressure wood laminate material.

5. One central metal leg/post with base/feet appropriate for specified flooring.

GRAPHIC SCALE N

A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

A101FAC-YR-NUM

PWD-MAINE

IN HOUSE DESIGN

1FIRST FLOOR LUNCH ROOM 2OFFICE 120 LAYOUT 3

OFFICE 125 AND 136

LAYOUT (OPTION 1)

OFFICE 139A AND 139B

LAYOUT (OPTION 2)

KEYNOTES

GENERAL SHEET NOTES

5COUNTER DETAIL, TYP.

AutoCAD SHX Text

1 SEATS

AutoCAD SHX Text

117 SF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 139A

AutoCAD SHX Text 139A

AutoCAD SHX Text 139B

AutoCAD SHX Text

1 SEATS

AutoCAD SHX Text

118 SF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 139B

AutoCAD SHX Text

40 SEATS

AutoCAD SHX Text

677 SF

AutoCAD SHX Text

LUNCH ROOM

AutoCAD SHX Text

AutoCAD SHX Text

9 SEATS

AutoCAD SHX Text

6 SEATS

AutoCAD SHX Text

565 SF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1 SEAT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

112 SF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

1 SEAT

AutoCAD SHX Text

129 SF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1/4" = 1'

AutoCAD SHX Text feet

AutoCAD SHX Text scale

AutoCAD SHX Text

CHECK GRAPHIC SCALE BEFORE USING

AutoCAD SHX Text

DEPARTMENT OF THE NAVY

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

PUBLIC WORKS DEPARTMENT - MAINE

AutoCAD SHX Text

NAVAL SHIPYARD - PORTSMOUTH, NH

AutoCAD SHX Text

DESIGN MANAGER

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

FEAD/PM&E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

FURNITURE LAYOUT PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1617115

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

AutoCAD SHX Text

ISSUED FOR BID

AutoCAD SHX Text

MM/DD/YYYY

AutoCAD SHX Text

DM

AutoCAD SHX Text

PORTSMOUTH NAVAL SHIPYARD

AutoCAD SHX Text

KITTERY, MAINE

AutoCAD SHX Text

MM OH-HVAC REPAIR SPACE OPTIMIZATION

AutoCAD SHX Text

& RENOVATIONS PNSY-43

AutoCAD SHX Text

AutoCAD SHX Text

LOUIS DITOMASSO

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DESIGNER

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

XXX

AutoCAD SHX Text

ERIK RODSTROM

AutoCAD SHX Text

ERIK RODSTROM

AutoCAD SHX Text

ERIK RODSTROM

AutoCAD SHX Text

ERIK RODSTROM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

DRAWFORM REVISION: DECEMBER 2018

AutoCAD SHX Text

JEFF HOYT

AutoCAD SHX Text A101

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A101

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A101

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A101

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

1. AT LEAST 36" CLEAR PATH OF TRAVEL TO DESK IS REQUIRED FOR AT LEAST 36" CLEAR PATH OF TRAVEL TO DESK IS REQUIRED FOR ALL WORKSTATIONS.

AutoCAD SHX Text

1. SEE FURNITURE SCOPE OF WORK FOR FURNITURE SPECIFICATIONS. SEE FURNITURE SCOPE OF WORK FOR FURNITURE SPECIFICATIONS. 2. SUBMIT PROPOSED FURNITURE LAYOUT TO NAVFAC FOR FINAL SUBMIT PROPOSED FURNITURE LAYOUT TO NAVFAC FOR FINAL APPROVED BEFORE ORDERING. 3. CONTRACTOR RESPONSIBLE FOR VERIFYING FIELD MEASUREMENTS.CONTRACTOR RESPONSIBLE FOR VERIFYING FIELD MEASUREMENTS.

AutoCAD SHX Text

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text A101

AutoCAD SHX Text

SCALE: 1-1/2"=1'-0"

AutoCAD SHX Text

DRYWALL ON BOTH SIDES

AutoCAD SHX Text

BLOCKING AS REQUIRED

AutoCAD SHX Text FLUSH MOUNTED COUNTER SUPPORT BRACKETS - BOD RAKKS EH SERIES. INSTALL PER MANUFACTURER RECOMMENDATIONS INCLUDING WOOD BLOCKING WITHIN METAL STUDS FOR EXTRA STRENGTH. SCRIBE DRYWALL AROUND BRACKET, SEAL, AND PAINT.

AutoCAD SHX Text scale

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text feet

AutoCAD SHX Text 3"

AutoCAD SHX Text 1 " = 1'12" = 1'

File details come from the government source that posted it. Updated .