Navy Marine Corps Intranet A superior Intranet and the service to back it up

NGEN INSIDE CABLE

PLANT (ISP)

INSTALLATION

STANDARDS

FINAL

Version 1.00 April 14, 2015

NSID-CS-0001

Created by HP for the NGEN Contract Number: N00039-13-D-0013

NGEN INSIDE CABLE PLANT (ISP) INSTALLATION STANDARDS -

Change History This document was created using the most recent version of the operations support template. The Next Generation Enterprise Network (NGEN) Knowledge Management Systems (KMS) version of the master template is controlled. All other versions are uncontrolled.

The following table contains a record of changes made to this document:

Change History Log

Date Published/

Revised

Version No. Author Section / Description of Change

06/20/2005 2.00 (NMCI) UNK Last Known Version under NMCI Contract 04/29/2011 1.00 (CoSC) Joel Dorr Reissuance under CoSC Contract 04/14/2015 1.00 (NGEN) Todd Allen Reissuance under NGEN Contract

NGEN operations support documents are identified on the title page as a draft or final, followed by the version number. Draft and final documents are defined and numbered, as follows:

• Initial drafts are numbered version 0.01 (D+1). Subsequent draft editions are numbered version 0.02 (D+2), 0.03 (D+3), 0.04 (D+4) and so forth.

• The first final edition is numbered version 1.0 (F+0). Subsequent final versions are numbered

1.1 (U+1), 1.2 (U+2), 2.0 (UA0), 3.0 (UB0), 4.0 (UC0) and so forth.

• After KMS finalizes the first version 1.0 (F+0), the following applies:

− The document cannot revert to a draft. All subsequent versions are finals.

− In the Change History Log, point of contact (POC) entries are numbered X.X.X (for example, 1.0.1, 1.1.1, 1.2.1, and so forth).

− The POC must request the latest version, go to the KMS SharePoint site and fill out the fields to request a document checkout.

• To view a master list of abbreviations, acronyms, and terms, click NGEN Glossary.

For more information about NMCI documentation, send an email to DMCIncomingRequest@nmci-isf.com.

FINAL i NSID-CS-0001 Created by HP for the NGEN Contract Number: N00039-13-D-0013 https://teams8.uspublicsector.ssn.hp.com/sites/KM/DMCDP/Lists/Document%20Checkout%20Requests/NewForm.aspx?RootFolder= https://www.homeport.navy.mil/support/articles/nmci-acronyms/ mailto:DMCIncomingRequest@nmci-isf.com

Table of Contents

1. INTRODUCTION\GENERAL INFORMATION

1.1 Introduction

1.2 General Information

1.2.1 Deviation from ISP Installation Standards

1.2.2 ISP Installation Test Results

1.2.3 Acceptance of Government installed ISP

1.2.4 PDS Installations

1.2.5 Red/Black Separation

1.2.6 ISP Installation Consistency

2. INSIDE PLANT (ISP) CABLE DESIGN STANDARDS

2.1 Inside Plant Horizontal Category 5e or Category 6 Cabling

2.2 Installation Materials

2.3 Inside Plant Fiber Optic Cable:

2.3.1 Fiber-To-The-Desk (FTTD) Standards

2.4 Copper and Fiber Panels

2.4.1 Patch Panels, Category 5e or Category 6

2.4.2 Wire Management Panels

2.4.3 Fiber Optic Closet Connector Housings (Fiber Panels)

3. STANDARD WIRING FOR NMCI SEATS

3.1 NMCI Seat Descriptions

3.2 Installation Descriptions

3.2.1 Standard UNCLASSIFIED Seat/Printer (One Drop)

3.2.2 Optional UNCLASSIFIED Seat (Four Drop)

3.2.3 Standard CLASSIFIED Seat/Printer

3.2.4 Standard UNCLASSIFIED Fiber To The Desk (FTTD) Connections

3.2.5 CLASSIFIED Fiber To The Desk (FTTD) Connection Option

3.3 3.3 Standard Configuration: Work Area

3.3.1 Flush Mount

3.3.2 Surface Mount

3.4 Standard Configuration: Data Closet (ISP)

3.5 Numbering and Naming Convention

Figures No table of figures entries found.

Tables No table of figures entries found.

FINAL ii NSID-CS-0001

1. INTRODUCTION\GENERAL INFORMATION

1.1 Introduction

This document defines the standards to be used for inside cable plant installations for the

NMCI network.

NOTE: The terms NMCI, CoSC and NGEN are used throughout the document. They all mean the same thing and interchangeable which is the network HP implemented for the US Navy under the NMCI contract, CoSC contract and now under the NGEN contract.

1.2 General Information

1.2.1 Deviation from ISP Installation Standards

Any deviation from the standards outlined in this document must be approved in advance by the Core Services Manager. At the time of the writing of this document that would be:

Matthew Galusha; Phone: 360.212.4081; E-mail: matthew.galusha@hp.com

1.2.2 ISP Installation Test Results

ISP Installation Test Results will consist of a PDF file download from the testing equipment and will include: UTP permanent link tests in accordance with TIA/EIA-568-B.1, B.2, and manufacturer’s guidelines.

HP requires Test Results that show how the installed cable lines up with the T-568B standard (i.e. Wire map, Frequency, Insertion Loss, NEXT, PSNEXT, Return Loss, Delay, Skew, Length, Identification of the Cable being tested, etc.).

1.2.3 Acceptance of Government installed ISP

Government installed ISP will be accepted by HP upon testing and labeling by HP per

NGEN standards. The testing and labeling will be the financial responsibility of the Government.

Where necessary, termination (or retermination) into the NMCI cabinet will also be the financial responsibility of the Government.

NOTE: Access to active NGEN IDF’s is restricted to HP only (staff and subcontractors).

1.2.4 PDS Installations

The standard security guidelines published by the Government on classified PDS (US

Navy/Marine Corps IA PUB 5239-22) will be followed.

1.2.5 Red/Black Separation

Classified and Unclassified ISP Installations shall be done in accordance with CNSSAM TEMPEST/1-13 for Red\Black separation.

FINAL 1 NSID-CS-0001

NOTE: As a general rule on NMCI\CoSC\NGEN, we have separated unclass/class processing by 3ft/36in and parallel cabling by six inches. I.e. the faceplates are separated by at least 3ft/36in and the horizontal cabling is separated by six inches.

1.2.6 ISP Installation Consistency

HP will retain same media type in a building and IDF for new installs. So buildings\IDFs with existing FTTD ISP Installations receive new FTTD, if existing installation is Cat 6, we will install Cat 6 to retain the same standard.

NOTE: The existing media type must equal or exceed Cat 5e requirements. This is the Normal style.

FINAL 2 NSID-CS-0001

2. INSIDE PLANT (ISP) CABLE DESIGN STANDARDS

2.1 Inside Plant Horizontal Category 5e or Category 6 Cabling

• Category 5e, 4-pair, 100 Ω UTP, CMP, (Plenum-rated), cable

• Category 5e, 4-pair, 100 Ω UTP, CMR, (Riser-rated), cable. (Where permitted by code)

• Category 6, 4-pair, 200 Ω UTP, CMP, (Plenum-rated), cable

• Category 6, 4-pair, 200 Ω UTP, CMR, (Riser-rated), cable. (Where permitted by code)

NOTE: It is not anticipated that individual cable drops will be required in support of the implementation of Voice Over IP (VoIP) within the NMCI network. But in the event these drops are required, any new cabling installed MUST be Category 5e specification or better.

NOTE: Total maximum horizontal passive cable length (NMCI patch panel to drop) shall not exceed 295 feet. If the ISP is being installed to a remote cabinet (i.e. GOV cabinet) with an ISP tie between the remote cabinet and the NMCI cabinet, the distance between the cabinets must be taken into consideration of the 295 feet maximum.

Color Coding: Color-coding will be provided through the use of colored Cable Sheathing as Table 1 lists. (colored icons that snap into the face of the jack\patch panel positions follow same color schema)

Table 1: Cable Sheath color-coding

Cable Purpose Cable Sheath (& Icon Color) Data #1 Blue Data #2 Green VoIP #1 White VoIP #2 Grey

Classified #1 Red Classified #2 Red

2.2 Installation Materials

IDC Termination: All Category 5e or Category 6 cabling will be terminated in the Data Cabinet/Telecommunications Room using Category 5e or Category 6, 24-port and/or 48-port, 110-type Insulation Displacement Contact (IDC) to 8-position T568-B configured patch panels.

(For smart configuration the four drops will be terminated in same patch panel).

• Standard configuration: One (1) data drops terminated on data patch panels.

o Optional configuration (if required): One (1) data drop terminated on data patch panels, and one (1) Voice-over-IP (VoIP) drop terminated using separate “Voice over IP” Category 5e or Category 6, 24-port and/or 48-port, 110-type IDC to 8 position, T568-B configured patch panels. However on smaller installations the same patch panel may be used for both voice and data cabling.

FINAL 3 NSID-CS-0001

o Optional Voice Terminal Blocks: HP may specify 66 /110 Blocks (Cat 5e or Cat 6 certified) as the final end point for the “Voice over IP” cabling in the data closet. Horizontal cabling from the work area will still be terminated on “Voice over IP” Category 5e or Category 6, 48 port, 110-type IDC to 8 position, patch panels.

Category 5e or Category 6, 4 pair, 100 Ω UTP or 200 Ω UTP, CMP or

CMR rated, cable will be extended from new “Voice over IP” patch panels to the wall fields 66/110 termination block for final connections. All 4 pairs will be mirror image through the 66/110 termination blocks to the patch panels.

J Hooks: The default cable installation will use J-hooks. The installation will be adjusted to conform to existing installation practice (J-hooks, ladder rack, cable trays, in wall/surface mount) for a building where possible. Where no current cabling exists, J-hooks will be the default method. PWC requirements will be supported if counter to J-hooks.

EMT: Facility requirements will dictate the EMT requirements needed to protect cabling.

Conduit size will be determined by fill ratio and is sized by current requirements.

Pin Configuration: Work Area Outlets will use Category 5e or Category 6, 8 position outlets supporting universal T568A/B wiring will be installed. All outlets shall be T568-B wiring configuration.

2.3 Inside Plant Fiber Optic Cable:

Table 2: Inside Plant Fiber Optic Cable

Type: Multimode (MM) fiber optic cable

Singlemode (SM) fiber optic cable

Use:

Fiber-To-The-Desktop

(FTTD)

UNCLASSIFIED,

CLASSIFIED

Mission Critical seat Closet to Closet

TIE cable (closet to closet)

UNCLASSIFIED,

CLASSIFIED

Mission Critical seat

Closet to Closet

Sheath Color: Orange Yellow Strand Count: Six (6) strand Twelve (12) strand Construction: dielectric strength member dielectric strength member

Buffering: Tight buffered Tight buffered Listing/Rating: CMR or CMP CMR or CMP Core/Cladding: 62.5/125 μm 8.3 - 9/125 μm/singlemode

Connector:

SC (FTTD)

ST (CLASSIFIED)

SC (TIE cable)

ST (CLASSIFIED)

FINAL 4 NSID-CS-0001

New installations are to utilize J-hooks as the baseline. Alternative means may be used if required by building codes/PWC practices.

2.3.1 Fiber-To-The-Desk (FTTD) Standards

• Data Closet fiber patch panels and Work Area faceplates will use the following color coding, based on pulling a 6-strand fiber optic cable:

Table 3: Inside Plant Fiber Optic Cable

Work Area Data Room

D1/S1-A XMT: Blue D1/S1-A RCV: Blue

D1/S1-B RCV: Orange D1/S1-B XMT: Orange

D2/S2-A XMT: Green D2/S2-A RCV: Green

D2/S2-B RCV: Brown D2/S2-B XMT: Brown

• The Slate and White strands are NOT terminated at both ends and they are NOT to be cut short.

o Unless specified otherwise:

UNCLASSIFIED fiber is terminated in duplex SC connectors CLASSIFIED fiber is terminated in dual ST, or duplex SC or LC connectors

• Multimode cable will have a maximum run length of 150 Meters from patch panel to the drop on the wall

2.4 Copper and Fiber Panels

2.4.1 Patch Panels, Category 5e or Category 6

• Under NGEN, only 24 or 48 Port Patch Panel will be used:

o Must be Category 5e or Category 6 compliant o Rear cable management o Icon labels/holders available in colors to match the cables

1 Rack Unit height - 24 port 2 Rack Unit height – 48 port o 110-type IDC rear cable termination or equipment

FINAL 5 NSID-CS-0001

o Universal T568A/B wiring o All patch panels shall be terminated to a T568-B wiring configuration

NOTE: 96-port patch panels are not allowed as cable management is insufficient to support moves, adds and changes.

2.4.2 Wire Management Panels

• Single-sided or Double-sided o Front cable management with cover o Optional Rear cable management o Optional Pass-through holes for front to back routing o Cable retention design

1 Rack Unit height: 1.75” 2 Rack Unit height : 3.50”

NOTE: All patch panels shall be matched with a horizontal wire management panel above and below the patch panel.

2.4.3 Fiber Optic Closet Connector Housings (Fiber Panels)

• 12, 24, 48, 72 and 144 Port Panels o 1, 2 and 4 Rack Unit heights: 1RU = 1.75 inches o SC duplex connector panels supporting 12 strands per panel for UNCLASSIFIED o ST dual, SC or LC duplex connector panels supporting 12 strands per panel for

CLASSIFIED (Installation of connector type is based on what is currently in place) o Splice trays supported (Fiber Distribution Centers) if required o Rack-mount and wall-mount versions

FINAL 6 NSID-CS-0001

3. STANDARD WIRING FOR NMCI SEATS

3.1 NMCI Seat Descriptions

Table 4: NMCI Seat Descriptions

Seat Type

Number of Cables- Cat 5e

(Drops) Number of Wall Plates

Cable Outlet Designations

Conduit Required

Figure Number

Jack, Connector

Type

Unclassified Seat (including mission critical seats)

1 1 D1 - 1 T568-B

Unclassified

Option 2 1 D1, V1 - 2 T568-B

Classified Seat (including mission critical seats)

1 1 S1 - 3 T568-B

Classified Printer 1 1 S1 3/4”

EMT 4 T568-B

Unclassified

Printer 1 1 D1 - 4 (w/o

EMT) T568-B

UNCLASSIFIED Fiber-To-Desk (FTTD) consisting of:

Unclassified 2 MM 2- Strand Pairs (4 strands)

1 D1, D2 - 5 Duplex

SC

CLASSIFIED Fiber-To-Desk (FTTD) consisting of:

Classified 2 MM 2- Strand Pairs (4 strands)

1 S1, S2 - 6 Dual ST

FINAL 7 NSID-CS-0001

3.2 Installation Descriptions

3.2.1 Standard UNCLASSIFIED Seat/Printer (One Drop)

• Unclassified Seat/Printer Installation –One Drop: One (1) Category 5e or Category 6 cable to a single wall plate. Terminate each cable on a Category 5e or Category 6, 8-position, modular insert. This standard also applies to unclassified mission critical seats.

o Cable 1 shall be designated D1 (Data 1) o Optional Configuration based on customer order: Cable 2 shall be designated D2

(Data 2)

NOTE: Unless otherwise specified by HP, the vendor is to install unclassified ISP to this standard for Copper installs.

120-1-3B

00700-0111-014 Unclassified Data Closet

Category 5e or 6 Patch Panel

D1 D2

D2 – Green (Optional Configuration based on Customer Order)

D1 - Blue

Category 5e or 6

Wall Plate Unclassified

Green IconBlue Icon

FIGURE 1

FINAL 8 NSID-CS-0001

3.2.2 Optional UNCLASSIFIED Seat (Four Drop)

• Optional Installation- Unclassified-Four Drops: Four (4) Category 5e or Category 6 cables to a single wall plate. Terminate each cable on a Category 5e or Category 6, 8-position, modular insert.

o Cable 1 shall be designated D1 (Data 1), o Cable 2 shall be designated D2 (Data 2), o Cable 3 (V1) and Cable 4 (V2) shall be designated for voice over IP

NOTE: This option will only be implemented at sites with VOIP capability and the government customer has ordered the applicable CLIN items. HP will direct the vendor to install to this option, otherwise the two drop option is to be used as the standard.

V1 V2

120-1-3B

00700-0111-014 Unclassified Data Closet

Category 5e or 6 Patch Panels

D1 D2

V2 - Gray

D1 - Blue

Category 5e or 6

D2 - Green

V1 - White

NOTE: D1, D2 are on separate patch panel from V1, V2

Wall Plate Unclassified

Green IconBlue Icon

White Icon Grey Icon

FIGURE 2

FINAL 9 NSID-CS-0001

3.2.3 Standard CLASSIFIED Seat/Printer

• The Classified Seat: One (1) Category 5e or Category 6 cable to a single wall plate.

Terminate each cable on a Category 5e or Category 6, 8-position, modular insert. This cable run must conform to all applicable Classified/PDS guidelines. Verify site requirements for SIPRNET are IAW Base Security Requirements. This standard also applies to classified mission critical seats.

o Cable 1 shall be designated S1 (Secure Data 1) o Optional Configuration based on customer order: Cable 2 shall be designated S2

(Secure Data 2)

00700-0111-014 Classified Data Closet

Category 5e or 6 Patch Panel

S1 S2

S2 - Red

S1 - Red

Wall Plate Classified

Red Icon Red Icon

FIGURE 3

FINAL 10 NSID-CS-0001

3.2.4 Standard UNCLASSIFIED Fiber To The Desk (FTTD) Connections

• Four strands terminated out of a 6-strand singlemode or multimode fiber optic cable;

pulled to a wall plate equipped with two (2) duplex SC connectors.

NOTE: Multimode cable will have a maximum run length of 150 Meters from patch panel to the

D2A D2B

120-1-3B

00700-0111-014 Unclassified Data Closet

Fiber Optic Patch Panel

D1A D1B

D2B - Brown

D1A - Blue

6 Strands of Multimode

62.5 Micron Fiber

D1B - Orange

D2A - Green

Wall Plate Unclassified

2 Strands Coiled and Spared out in Work Box

(White and Slate) Duplex SC Connectors

FIGURE 4

3.2.5 CLASSIFIED Fiber To The Desk (FTTD) Connection Option

• Four strands terminated out of a 6-strand singlemode (SM) or multimode (MM) fiber optic cable pulled to single wall plate equipped with two (2) dual ST connectors for CLASSIFIED / SIPRNET access. This cable run must conform to all applicable

FINAL 11 NSID-CS-0001

Classified/PDS guidelines. Verify site requirements for SIPRNET are IAW Base Security Requirements.

NOTE: Multimode cable will have a maximum run length of 150 Meters from patch panel to the

S2A S2B

00700-0111-014 Classified Data Closet

Fiber Optic Patch Panel

S1A S1B

S2B - Brown

S1A - Blue

6 Strands of Multimode

62.5 Micron Fiber

S1B - Orange

S2A - Green

Wall Plate Classified

2 Strands Coiled and Spared out in Work Box

(White and Slate) Dual ST, Duplex LC or Duplex SC Connectors

FIGURE 5

3.3 3.3 Standard Configuration: Work Area

3.3.1 Flush Mount

• Placement to work area: via J-Hook

• Cable:

FINAL 12 NSID-CS-0001

o Category 5e or Category 6 o Plenum-listed o 4-pair o UTP

• Mounting: In-wall box eliminator (i.e.: “Caddy” MPLS),

• Faceplate: single-gang 4-port,

• Jacks: dual 8-position Category 5e or Category 6 jacks and blank inserts

• Color: light Ivory with color coded icon for jacks

3.3.2 Surface Mount

• Placement to work area: via J-Hook and ten feet (10’) of surface mount raceway

• Cable:

o Category 5e or Category 6 o Plenum-listed o 4-pair o UTP

• Maximum cable length: 250 feet

• Mounting: single-gang surface mount box

• Faceplate: single-gang 4-port,

• Jacks: dual 8-position Category 5e or Category 6 jacks and blank inserts

• Color: light Ivory with color coded icon for jacks

3.4 Standard Configuration: Data Closet (ISP)

• Patch Panel: Category 5e or Category 6, 8-position, 24 or 48 port

• Fiber Panel: Fiber Optic Termination Units

• Housing: Open bay relay rack or equipment cabinet (Unclassified & Classified)

• Cable management: horizontal and vertical management panels

• Cable Support: Stovepipe, Ladder or Cable Tray providing support from rack to wall

• Other:

o Telecommunications Grounding Busbar o Sleeves and/or Slots o Fire-stop system

3.5 Numbering and Naming Convention

FINAL 13 NSID-CS-0001

V1 V2

120-1-3B

00700-0111-014

D1 D2

Cable ID

Building# - Room# - Drop/Seat#

Closet# - Rack# - Patch Panel#

Green IconBlue Icon

White Icon Grey Icon

120-1-3B

00700-0111-014

S1 S2

Wall Plate Classified

Building# - Room# - Drop/Seat#

Wall Plate Unclassified

Closet# - Rack# - Patch Panel#

Red Icon Red Icon

FIGURE 6

• Un-numbered cubical: When a cubical area is found unnumbered, it shall be numbered clock-wise from North. The assigned numbers will be noted on the red lined floor plan.

• If wiring closet room number is not available, label wiring closets, M01 for main 01, S01 for sub-closet 01, and clock-wise from North.

• If room numbers are unavailable, start numbering rooms north to south, west to east.

• Drop numbers are in sequence by wiring closet.

• Patch panels are identified by a number followed by F for front and B for back as necessary.

• Numbers next to jacks are always D1, D2, S1, S2, V1 and V2, as they are part of the cable ID convention and not a patch panel number. D is for Data and V for Voice over IP.

NOTE: This NGEN wall plate naming scheme supersedes all existing labeling schemes in place.

Include all dashes and pad the appropriate numbers with zeros (0) as needed. This information goes into a central database; SO DO NOT DEVIATE FROM IT. Exceptions must be approved by Matthew Galusha in advance of install.

FINAL 14 NSID-CS-0001

1. Introduction\General Information
1.1 Introduction
1.2 General Information
1.2.1 Deviation from ISP Installation Standards
1.2.2 ISP Installation Test Results
1.2.3 Acceptance of Government installed ISP
1.2.4 PDS Installations
1.2.5 Red/Black Separation
1.2.6 ISP Installation Consistency
2. Inside Plant (ISP) Cable Design Standards
2.1 Inside Plant Horizontal Category 5e or Category 6 Cabling
2.2 Installation Materials
2.3 Inside Plant Fiber Optic Cable:
2.3.1 Fiber-To-The-Desk (FTTD) Standards
2.4 Copper and Fiber Panels
2.4.1 Patch Panels, Category 5e or Category 6
2.4.2 Wire Management Panels
2.4.3 Fiber Optic Closet Connector Housings (Fiber Panels)
3. Standard Wiring for NMCI Seats
3.1 NMCI Seat Descriptions
3.2 Installation Descriptions
3.2.1 Standard UNCLASSIFIED Seat/Printer (One Drop)
3.2.2 Optional UNCLASSIFIED Seat (Four Drop)
3.2.3 Standard CLASSIFIED Seat/Printer
3.2.4 Standard UNCLASSIFIED Fiber To The Desk (FTTD) Connections
3.2.5 CLASSIFIED Fiber To The Desk (FTTD) Connection Option
3.3 3.3 Standard Configuration: Work Area
3.3.1 Flush Mount
3.3.2 Surface Mount
3.4 Standard Configuration: Data Closet (ISP)
3.5 Numbering and Naming Convention