Navy Marine Corps Intranet A superior Intranet and the service to back it up
NGEN INSIDE CABLE
PLANT (ISP)
INSTALLATION
STANDARDS
FINAL
Version 1.00 April 14, 2015
NSID-CS-0001
Created by HP for the NGEN Contract Number: N00039-13-D-0013
NGEN INSIDE CABLE PLANT (ISP) INSTALLATION STANDARDS -
Change History This document was created using the most recent version of the operations support template. The Next Generation Enterprise Network (NGEN) Knowledge Management Systems (KMS) version of the master template is controlled. All other versions are uncontrolled.
The following table contains a record of changes made to this document:
Change History Log
Date Published/
Revised
Version No. Author Section / Description of Change
06/20/2005 2.00 (NMCI) UNK Last Known Version under NMCI Contract 04/29/2011 1.00 (CoSC) Joel Dorr Reissuance under CoSC Contract 04/14/2015 1.00 (NGEN) Todd Allen Reissuance under NGEN Contract
NGEN operations support documents are identified on the title page as a draft or final, followed by the version number. Draft and final documents are defined and numbered, as follows:
• Initial drafts are numbered version 0.01 (D+1). Subsequent draft editions are numbered version 0.02 (D+2), 0.03 (D+3), 0.04 (D+4) and so forth.
• The first final edition is numbered version 1.0 (F+0). Subsequent final versions are numbered
1.1 (U+1), 1.2 (U+2), 2.0 (UA0), 3.0 (UB0), 4.0 (UC0) and so forth.
• After KMS finalizes the first version 1.0 (F+0), the following applies:
− The document cannot revert to a draft. All subsequent versions are finals.
− In the Change History Log, point of contact (POC) entries are numbered X.X.X (for example, 1.0.1, 1.1.1, 1.2.1, and so forth).
− The POC must request the latest version, go to the KMS SharePoint site and fill out the fields to request a document checkout.
• To view a master list of abbreviations, acronyms, and terms, click NGEN Glossary.
For more information about NMCI documentation, send an email to DMCIncomingRequest@nmci-isf.com.
FINAL i NSID-CS-0001 Created by HP for the NGEN Contract Number: N00039-13-D-0013 https://teams8.uspublicsector.ssn.hp.com/sites/KM/DMCDP/Lists/Document%20Checkout%20Requests/NewForm.aspx?RootFolder= https://www.homeport.navy.mil/support/articles/nmci-acronyms/ mailto:DMCIncomingRequest@nmci-isf.com
Table of Contents
1. INTRODUCTION\GENERAL INFORMATION
1.1 Introduction
1.2 General Information
1.2.1 Deviation from ISP Installation Standards
1.2.2 ISP Installation Test Results
1.2.3 Acceptance of Government installed ISP
1.2.4 PDS Installations
1.2.5 Red/Black Separation
1.2.6 ISP Installation Consistency
2. INSIDE PLANT (ISP) CABLE DESIGN STANDARDS
2.1 Inside Plant Horizontal Category 5e or Category 6 Cabling
2.2 Installation Materials
2.3 Inside Plant Fiber Optic Cable:
2.3.1 Fiber-To-The-Desk (FTTD) Standards
2.4 Copper and Fiber Panels
2.4.1 Patch Panels, Category 5e or Category 6
2.4.2 Wire Management Panels
2.4.3 Fiber Optic Closet Connector Housings (Fiber Panels)
3. STANDARD WIRING FOR NMCI SEATS
3.1 NMCI Seat Descriptions
3.2 Installation Descriptions
3.2.1 Standard UNCLASSIFIED Seat/Printer (One Drop)
3.2.2 Optional UNCLASSIFIED Seat (Four Drop)
3.2.3 Standard CLASSIFIED Seat/Printer
3.2.4 Standard UNCLASSIFIED Fiber To The Desk (FTTD) Connections
3.2.5 CLASSIFIED Fiber To The Desk (FTTD) Connection Option
3.3 3.3 Standard Configuration: Work Area
3.3.1 Flush Mount
3.3.2 Surface Mount
3.4 Standard Configuration: Data Closet (ISP)
3.5 Numbering and Naming Convention
Figures No table of figures entries found.
Tables No table of figures entries found.
FINAL ii NSID-CS-0001
1. INTRODUCTION\GENERAL INFORMATION
1.1 Introduction
This document defines the standards to be used for inside cable plant installations for the
NMCI network.
NOTE: The terms NMCI, CoSC and NGEN are used throughout the document. They all mean the same thing and interchangeable which is the network HP implemented for the US Navy under the NMCI contract, CoSC contract and now under the NGEN contract.
1.2 General Information
1.2.1 Deviation from ISP Installation Standards
Any deviation from the standards outlined in this document must be approved in advance by the Core Services Manager. At the time of the writing of this document that would be:
Matthew Galusha; Phone: 360.212.4081; E-mail: matthew.galusha@hp.com
1.2.2 ISP Installation Test Results
ISP Installation Test Results will consist of a PDF file download from the testing equipment and will include: UTP permanent link tests in accordance with TIA/EIA-568-B.1, B.2, and manufacturer’s guidelines.
HP requires Test Results that show how the installed cable lines up with the T-568B standard (i.e. Wire map, Frequency, Insertion Loss, NEXT, PSNEXT, Return Loss, Delay, Skew, Length, Identification of the Cable being tested, etc.).
1.2.3 Acceptance of Government installed ISP
Government installed ISP will be accepted by HP upon testing and labeling by HP per
NGEN standards. The testing and labeling will be the financial responsibility of the Government.
Where necessary, termination (or retermination) into the NMCI cabinet will also be the financial responsibility of the Government.
NOTE: Access to active NGEN IDF’s is restricted to HP only (staff and subcontractors).
1.2.4 PDS Installations
The standard security guidelines published by the Government on classified PDS (US
Navy/Marine Corps IA PUB 5239-22) will be followed.
1.2.5 Red/Black Separation
Classified and Unclassified ISP Installations shall be done in accordance with CNSSAM TEMPEST/1-13 for Red\Black separation.
FINAL 1 NSID-CS-0001
NOTE: As a general rule on NMCI\CoSC\NGEN, we have separated unclass/class processing by 3ft/36in and parallel cabling by six inches. I.e. the faceplates are separated by at least 3ft/36in and the horizontal cabling is separated by six inches.
1.2.6 ISP Installation Consistency
HP will retain same media type in a building and IDF for new installs. So buildings\IDFs with existing FTTD ISP Installations receive new FTTD, if existing installation is Cat 6, we will install Cat 6 to retain the same standard.
NOTE: The existing media type must equal or exceed Cat 5e requirements. This is the Normal style.
FINAL 2 NSID-CS-0001
2. INSIDE PLANT (ISP) CABLE DESIGN STANDARDS
2.1 Inside Plant Horizontal Category 5e or Category 6 Cabling
• Category 5e, 4-pair, 100 Ω UTP, CMP, (Plenum-rated), cable
• Category 5e, 4-pair, 100 Ω UTP, CMR, (Riser-rated), cable. (Where permitted by code)
• Category 6, 4-pair, 200 Ω UTP, CMP, (Plenum-rated), cable
• Category 6, 4-pair, 200 Ω UTP, CMR, (Riser-rated), cable. (Where permitted by code)
NOTE: It is not anticipated that individual cable drops will be required in support of the implementation of Voice Over IP (VoIP) within the NMCI network. But in the event these drops are required, any new cabling installed MUST be Category 5e specification or better.
NOTE: Total maximum horizontal passive cable length (NMCI patch panel to drop) shall not exceed 295 feet. If the ISP is being installed to a remote cabinet (i.e. GOV cabinet) with an ISP tie between the remote cabinet and the NMCI cabinet, the distance between the cabinets must be taken into consideration of the 295 feet maximum.
Color Coding: Color-coding will be provided through the use of colored Cable Sheathing as Table 1 lists. (colored icons that snap into the face of the jack\patch panel positions follow same color schema)
Table 1: Cable Sheath color-coding
Cable Purpose Cable Sheath (& Icon Color) Data #1 Blue Data #2 Green VoIP #1 White VoIP #2 Grey
Classified #1 Red Classified #2 Red
2.2 Installation Materials
IDC Termination: All Category 5e or Category 6 cabling will be terminated in the Data Cabinet/Telecommunications Room using Category 5e or Category 6, 24-port and/or 48-port, 110-type Insulation Displacement Contact (IDC) to 8-position T568-B configured patch panels.
(For smart configuration the four drops will be terminated in same patch panel).
• Standard configuration: One (1) data drops terminated on data patch panels.
o Optional configuration (if required): One (1) data drop terminated on data patch panels, and one (1) Voice-over-IP (VoIP) drop terminated using separate “Voice over IP” Category 5e or Category 6, 24-port and/or 48-port, 110-type IDC to 8 position, T568-B configured patch panels. However on smaller installations the same patch panel may be used for both voice and data cabling.
FINAL 3 NSID-CS-0001
o Optional Voice Terminal Blocks: HP may specify 66 /110 Blocks (Cat 5e or Cat 6 certified) as the final end point for the “Voice over IP” cabling in the data closet. Horizontal cabling from the work area will still be terminated on “Voice over IP” Category 5e or Category 6, 48 port, 110-type IDC to 8 position, patch panels.
Category 5e or Category 6, 4 pair, 100 Ω UTP or 200 Ω UTP, CMP or
CMR rated, cable will be extended from new “Voice over IP” patch panels to the wall fields 66/110 termination block for final connections. All 4 pairs will be mirror image through the 66/110 termination blocks to the patch panels.
J Hooks: The default cable installation will use J-hooks. The installation will be adjusted to conform to existing installation practice (J-hooks, ladder rack, cable trays, in wall/surface mount) for a building where possible. Where no current cabling exists, J-hooks will be the default method. PWC requirements will be supported if counter to J-hooks.
EMT: Facility requirements will dictate the EMT requirements needed to protect cabling.
Conduit size will be determined by fill ratio and is sized by current requirements.
Pin Configuration: Work Area Outlets will use Category 5e or Category 6, 8 position outlets supporting universal T568A/B wiring will be installed. All outlets shall be T568-B wiring configuration.
2.3 Inside Plant Fiber Optic Cable:
Table 2: Inside Plant Fiber Optic Cable
Type: Multimode (MM) fiber optic cable
Singlemode (SM) fiber optic cable
Use:
Fiber-To-The-Desktop
(FTTD)
UNCLASSIFIED,
CLASSIFIED
Mission Critical seat Closet to Closet
TIE cable (closet to closet)
UNCLASSIFIED,
CLASSIFIED
Mission Critical seat
Closet to Closet
Sheath Color: Orange Yellow Strand Count: Six (6) strand Twelve (12) strand Construction: dielectric strength member dielectric strength member
Buffering: Tight buffered Tight buffered Listing/Rating: CMR or CMP CMR or CMP Core/Cladding: 62.5/125 μm 8.3 - 9/125 μm/singlemode
Connector:
SC (FTTD)
ST (CLASSIFIED)
SC (TIE cable)
ST (CLASSIFIED)
FINAL 4 NSID-CS-0001
New installations are to utilize J-hooks as the baseline. Alternative means may be used if required by building codes/PWC practices.
2.3.1 Fiber-To-The-Desk (FTTD) Standards
• Data Closet fiber patch panels and Work Area faceplates will use the following color coding, based on pulling a 6-strand fiber optic cable:
Table 3: Inside Plant Fiber Optic Cable
Work Area Data Room
D1/S1-A XMT: Blue D1/S1-A RCV: Blue
D1/S1-B RCV: Orange D1/S1-B XMT: Orange
D2/S2-A XMT: Green D2/S2-A RCV: Green
D2/S2-B RCV: Brown D2/S2-B XMT: Brown
• The Slate and White strands are NOT terminated at both ends and they are NOT to be cut short.
o Unless specified otherwise:
UNCLASSIFIED fiber is terminated in duplex SC connectors CLASSIFIED fiber is terminated in dual ST, or duplex SC or LC connectors
• Multimode cable will have a maximum run length of 150 Meters from patch panel to the drop on the wall
2.4 Copper and Fiber Panels
2.4.1 Patch Panels, Category 5e or Category 6
• Under NGEN, only 24 or 48 Port Patch Panel will be used:
o Must be Category 5e or Category 6 compliant o Rear cable management o Icon labels/holders available in colors to match the cables
1 Rack Unit height - 24 port 2 Rack Unit height – 48 port o 110-type IDC rear cable termination or equipment
FINAL 5 NSID-CS-0001
o Universal T568A/B wiring o All patch panels shall be terminated to a T568-B wiring configuration
NOTE: 96-port patch panels are not allowed as cable management is insufficient to support moves, adds and changes.
2.4.2 Wire Management Panels
• Single-sided or Double-sided o Front cable management with cover o Optional Rear cable management o Optional Pass-through holes for front to back routing o Cable retention design
1 Rack Unit height: 1.75” 2 Rack Unit height : 3.50”
NOTE: All patch panels shall be matched with a horizontal wire management panel above and below the patch panel.
2.4.3 Fiber Optic Closet Connector Housings (Fiber Panels)
• 12, 24, 48, 72 and 144 Port Panels o 1, 2 and 4 Rack Unit heights: 1RU = 1.75 inches o SC duplex connector panels supporting 12 strands per panel for UNCLASSIFIED o ST dual, SC or LC duplex connector panels supporting 12 strands per panel for
CLASSIFIED (Installation of connector type is based on what is currently in place) o Splice trays supported (Fiber Distribution Centers) if required o Rack-mount and wall-mount versions
FINAL 6 NSID-CS-0001
3. STANDARD WIRING FOR NMCI SEATS
3.1 NMCI Seat Descriptions
Table 4: NMCI Seat Descriptions
Seat Type
Number of Cables- Cat 5e
(Drops) Number of Wall Plates
Cable Outlet Designations
Conduit Required
Figure Number
Jack, Connector
Type
Unclassified Seat (including mission critical seats)
1 1 D1 - 1 T568-B
Unclassified
Option 2 1 D1, V1 - 2 T568-B
Classified Seat (including mission critical seats)
1 1 S1 - 3 T568-B
Classified Printer 1 1 S1 3/4”
EMT 4 T568-B
Unclassified
Printer 1 1 D1 - 4 (w/o
EMT) T568-B
UNCLASSIFIED Fiber-To-Desk (FTTD) consisting of:
Unclassified 2 MM 2- Strand Pairs (4 strands)
1 D1, D2 - 5 Duplex
SC
CLASSIFIED Fiber-To-Desk (FTTD) consisting of:
Classified 2 MM 2- Strand Pairs (4 strands)
1 S1, S2 - 6 Dual ST
FINAL 7 NSID-CS-0001
3.2 Installation Descriptions
3.2.1 Standard UNCLASSIFIED Seat/Printer (One Drop)
• Unclassified Seat/Printer Installation –One Drop: One (1) Category 5e or Category 6 cable to a single wall plate. Terminate each cable on a Category 5e or Category 6, 8-position, modular insert. This standard also applies to unclassified mission critical seats.
o Cable 1 shall be designated D1 (Data 1) o Optional Configuration based on customer order: Cable 2 shall be designated D2
(Data 2)
NOTE: Unless otherwise specified by HP, the vendor is to install unclassified ISP to this standard for Copper installs.
120-1-3B
00700-0111-014 Unclassified Data Closet
Category 5e or 6 Patch Panel
D1 D2
D2 – Green (Optional Configuration based on Customer Order)
D1 - Blue
Category 5e or 6
Wall Plate Unclassified
Green IconBlue Icon
FIGURE 1
FINAL 8 NSID-CS-0001
3.2.2 Optional UNCLASSIFIED Seat (Four Drop)
• Optional Installation- Unclassified-Four Drops: Four (4) Category 5e or Category 6 cables to a single wall plate. Terminate each cable on a Category 5e or Category 6, 8-position, modular insert.
o Cable 1 shall be designated D1 (Data 1), o Cable 2 shall be designated D2 (Data 2), o Cable 3 (V1) and Cable 4 (V2) shall be designated for voice over IP
NOTE: This option will only be implemented at sites with VOIP capability and the government customer has ordered the applicable CLIN items. HP will direct the vendor to install to this option, otherwise the two drop option is to be used as the standard.
V1 V2
120-1-3B
00700-0111-014 Unclassified Data Closet
Category 5e or 6 Patch Panels
D1 D2
V2 - Gray
D1 - Blue
Category 5e or 6
D2 - Green
V1 - White
NOTE: D1, D2 are on separate patch panel from V1, V2
Wall Plate Unclassified
Green IconBlue Icon
White Icon Grey Icon
FIGURE 2
FINAL 9 NSID-CS-0001
3.2.3 Standard CLASSIFIED Seat/Printer
• The Classified Seat: One (1) Category 5e or Category 6 cable to a single wall plate.
Terminate each cable on a Category 5e or Category 6, 8-position, modular insert. This cable run must conform to all applicable Classified/PDS guidelines. Verify site requirements for SIPRNET are IAW Base Security Requirements. This standard also applies to classified mission critical seats.
o Cable 1 shall be designated S1 (Secure Data 1) o Optional Configuration based on customer order: Cable 2 shall be designated S2
(Secure Data 2)
00700-0111-014 Classified Data Closet
Category 5e or 6 Patch Panel
S1 S2
S2 - Red
S1 - Red
Wall Plate Classified
Red Icon Red Icon
FIGURE 3
FINAL 10 NSID-CS-0001
3.2.4 Standard UNCLASSIFIED Fiber To The Desk (FTTD) Connections
• Four strands terminated out of a 6-strand singlemode or multimode fiber optic cable;
pulled to a wall plate equipped with two (2) duplex SC connectors.
NOTE: Multimode cable will have a maximum run length of 150 Meters from patch panel to the
D2A D2B
120-1-3B
00700-0111-014 Unclassified Data Closet
Fiber Optic Patch Panel
D1A D1B
D2B - Brown
D1A - Blue
6 Strands of Multimode
62.5 Micron Fiber
D1B - Orange
D2A - Green
Wall Plate Unclassified
2 Strands Coiled and Spared out in Work Box
(White and Slate) Duplex SC Connectors
FIGURE 4
3.2.5 CLASSIFIED Fiber To The Desk (FTTD) Connection Option
• Four strands terminated out of a 6-strand singlemode (SM) or multimode (MM) fiber optic cable pulled to single wall plate equipped with two (2) dual ST connectors for CLASSIFIED / SIPRNET access. This cable run must conform to all applicable
FINAL 11 NSID-CS-0001
Classified/PDS guidelines. Verify site requirements for SIPRNET are IAW Base Security Requirements.
NOTE: Multimode cable will have a maximum run length of 150 Meters from patch panel to the
S2A S2B
00700-0111-014 Classified Data Closet
Fiber Optic Patch Panel
S1A S1B
S2B - Brown
S1A - Blue
6 Strands of Multimode
62.5 Micron Fiber
S1B - Orange
S2A - Green
Wall Plate Classified
2 Strands Coiled and Spared out in Work Box
(White and Slate) Dual ST, Duplex LC or Duplex SC Connectors
FIGURE 5
3.3 3.3 Standard Configuration: Work Area
3.3.1 Flush Mount
• Placement to work area: via J-Hook
• Cable:
FINAL 12 NSID-CS-0001
o Category 5e or Category 6 o Plenum-listed o 4-pair o UTP
• Mounting: In-wall box eliminator (i.e.: “Caddy” MPLS),
• Faceplate: single-gang 4-port,
• Jacks: dual 8-position Category 5e or Category 6 jacks and blank inserts
• Color: light Ivory with color coded icon for jacks
3.3.2 Surface Mount
• Placement to work area: via J-Hook and ten feet (10’) of surface mount raceway
• Cable:
o Category 5e or Category 6 o Plenum-listed o 4-pair o UTP
• Maximum cable length: 250 feet
• Mounting: single-gang surface mount box
• Faceplate: single-gang 4-port,
• Jacks: dual 8-position Category 5e or Category 6 jacks and blank inserts
• Color: light Ivory with color coded icon for jacks
3.4 Standard Configuration: Data Closet (ISP)
• Patch Panel: Category 5e or Category 6, 8-position, 24 or 48 port
• Fiber Panel: Fiber Optic Termination Units
• Housing: Open bay relay rack or equipment cabinet (Unclassified & Classified)
• Cable management: horizontal and vertical management panels
• Cable Support: Stovepipe, Ladder or Cable Tray providing support from rack to wall
• Other:
o Telecommunications Grounding Busbar o Sleeves and/or Slots o Fire-stop system
3.5 Numbering and Naming Convention
FINAL 13 NSID-CS-0001
V1 V2
120-1-3B
00700-0111-014
D1 D2
Cable ID
Building# - Room# - Drop/Seat#
Closet# - Rack# - Patch Panel#
Green IconBlue Icon
White Icon Grey Icon
120-1-3B
00700-0111-014
S1 S2
Wall Plate Classified
Building# - Room# - Drop/Seat#
Wall Plate Unclassified
Closet# - Rack# - Patch Panel#
Red Icon Red Icon
FIGURE 6
• Un-numbered cubical: When a cubical area is found unnumbered, it shall be numbered clock-wise from North. The assigned numbers will be noted on the red lined floor plan.
• If wiring closet room number is not available, label wiring closets, M01 for main 01, S01 for sub-closet 01, and clock-wise from North.
• If room numbers are unavailable, start numbering rooms north to south, west to east.
• Drop numbers are in sequence by wiring closet.
• Patch panels are identified by a number followed by F for front and B for back as necessary.
• Numbers next to jacks are always D1, D2, S1, S2, V1 and V2, as they are part of the cable ID convention and not a patch panel number. D is for Data and V for Voice over IP.
NOTE: This NGEN wall plate naming scheme supersedes all existing labeling schemes in place.
Include all dashes and pad the appropriate numbers with zeros (0) as needed. This information goes into a central database; SO DO NOT DEVIATE FROM IT. Exceptions must be approved by Matthew Galusha in advance of install.
FINAL 14 NSID-CS-0001
| 1. Introduction\General Information |
| 1.1 Introduction |
| 1.2 General Information |
| 1.2.1 Deviation from ISP Installation Standards |
| 1.2.2 ISP Installation Test Results |
| 1.2.3 Acceptance of Government installed ISP |
| 1.2.4 PDS Installations |
| 1.2.5 Red/Black Separation |
| 1.2.6 ISP Installation Consistency |
| 2. Inside Plant (ISP) Cable Design Standards |
| 2.1 Inside Plant Horizontal Category 5e or Category 6 Cabling |
| 2.2 Installation Materials |
| 2.3 Inside Plant Fiber Optic Cable: |
| 2.3.1 Fiber-To-The-Desk (FTTD) Standards |
| 2.4 Copper and Fiber Panels |
| 2.4.1 Patch Panels, Category 5e or Category 6 |
| 2.4.2 Wire Management Panels |
| 2.4.3 Fiber Optic Closet Connector Housings (Fiber Panels) |
| 3. Standard Wiring for NMCI Seats |
| 3.1 NMCI Seat Descriptions |
| 3.2 Installation Descriptions |
| 3.2.1 Standard UNCLASSIFIED Seat/Printer (One Drop) |
| 3.2.2 Optional UNCLASSIFIED Seat (Four Drop) |
| 3.2.3 Standard CLASSIFIED Seat/Printer |
| 3.2.4 Standard UNCLASSIFIED Fiber To The Desk (FTTD) Connections |
| 3.2.5 CLASSIFIED Fiber To The Desk (FTTD) Connection Option |
| 3.3 3.3 Standard Configuration: Work Area |
| 3.3.1 Flush Mount |
| 3.3.2 Surface Mount |
| 3.4 Standard Configuration: Data Closet (ISP) |
| 3.5 Numbering and Naming Convention |