Attachment 3 - Water Level Spec - 7ML53131..060.A0 (ID 3482090).pdf

PDF 95 KB Posted

Attached to
2026 Closed Landfill Leachate Systems Improvements
Solicitation number
2132954
Issued by
Tioga County, Garden City South CDP, New York

About this file

This is a technical specification datasheet for water level measurement equipment specified for a state or local contract opportunity. The document provides detailed specifications for the SITRANS LR110 Radar level transmitter, manufactured by Siemens (ordering code 7ML53131..060.A0), a non-contact continuous radar-based level measurement device designed for liquids, slurries, and solids with a maximum measuring range of 15 meters (49.2 feet). The equipment features an 80 GHz operating frequency, 8-degree beam angle, and measurement accuracy of 2 mm maximum deviation at the analog output. The transmitter operates under medium temperatures ranging from -40°C to +80°C with operating pressure limits of -1 bar to 3 bar and requires a minimum dielectric constant of 1.6 for the process medium.

The SITRANS LR110 is engineered for harsh environmental conditions with IP66 and IP68 degree of protection ratings, operates on 24V DC external power supply, and includes integrated cable connection with polyurethane (PUR) material. The device incorporates polyvinylidene fluoride (PVDF) materials for the antenna, enclosure, and cable entry components and utilizes Bluetooth and MODBUS RTU communication protocols. The transmitter holds multiple certifications and approvals including CE, CRN, CSA, FCC, FM, and RCM designations, and complies with EC Regulation 1935/2004 for food-contact materials and PED 2014/68/EU pressure equipment directives for gas group 1 and liquid group 1 classification. The device weighs 1.45 kg and features galvanic isolation with recommended fastening bolt torque specifications of 6 Nm and maximum torque of 7 Nm.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Creation date: 05/30/2025 s

This is only an extract from the technical data. For more details, see the FI 01 catalog or the Industry Mall.

Datasheet for SITRANS LR110 Radar level transmitter, continuous, non-contact, 15m (49.2ft) range, for liquids, slurries, or solids, integrated cable connection.

Ordering data: 7ML53131..060.A0

General Manufacturer Siemens Supplier Siemens Product designation Radar level meter Brand name SITRANS LR110 Type designation SITRANS LR110 Radar level transmitter, continuous, non-contact, 15m

(49.2ft) range, for liquids, slurries, or solids, integrated cable connection.

Net weight 1.45 kg Reference code acc. IEC 81346-2:2009 BL Reference code acc. IEC 81346-2:2019 BFA Slogan compact radar transmitter for continuous level measurement of liquids, slurries, and solids

Mode of operation and application Measuring principle radar Operating frequency 80 GHz Beam angle 8 Degree

Input Measurand Distance, Level, Volume, Volume flow

Measuring range Measuring range 0 m...15 m Near range suppression 0 m

Measuring span Measuring span 0.1 m...15 m

Accuracy Measurement deviation at the analog output, interval 1 (maximum)

2 mm

Operating conditions Medium temperature -40 °C...+80 °C Degree of pollution Pollution degree 4 Standard for the degree of pollution IEC 61010-1 Overvoltage class Installation category III Standard for the overvoltage class IEC 61010-1

Process medium Dielectric constant (minimum) 1.6

Pressure Operating pressure, relative -1 bar...3 bar

This is only an extract from the technical data. For more details, see the FI 01 catalog or the Industry Mall.

Datasheet for SITRANS LR110 Radar level transmitter, continuous, non-contact, 15m (49.2ft) range, for liquids, slurries, or solids, integrated cable connection.

Ordering data: 7ML53131..060.A0

Environmental conditions Ambient temperature during operation -40 °C...+80 °C Ambient temperature during storage -40 °C...+80 °C Ambient temperature during transport -40 °C...+80 °C Relative humidity during operation 0 % Relative humidity during operation (maximum) 100 %

Degree of protection IP rating IP66, IP68

Electromagnetic compatibility EMC Standard for EMC IEC 61326-1

Structural Design

Mechanical design Design of the device compact version, sensor integrated Model of the antenna Lens antenna

...Material

....Enclosure Material Polyvinylidene fluoride (PVDF)

....Sensor Material of the antenna polyvinylidene-fluoride (PVDF)

....Cable entry & cable gland Material of the cable entry Polyvinylidene fluoride (PVDF)

....Miscellaneous Material of the connection cable polyurethane (PUR)

...Mounting Tightening torque of fastening bolt (recommended) 6 000030 Tightening torque of fastening bolt (maximum) 7 000030

Electrical connections Potential insulation galvanic isolation Number of cable entries 1 Design of the cable entry potted

Display and operating controls Display without display

Power supply

Electrical Type of power supply External Voltage type DC Nominal voltage, DC 24 V

This is only an extract from the technical data. For more details, see the FI 01 catalog or the Industry Mall.

Datasheet for SITRANS LR110 Radar level transmitter, continuous, non-contact, 15m (49.2ft) range, for liquids, slurries, or solids, integrated cable connection.

Ordering data: 7ML53131..060.A0

Communication Protocol Bluetooth, MODBUS RTU

Certificates and approvals Verification of suitability CE, CRN, CSA, EC 1935/2004 (Regulation on materials and articles intended to come into contact with food), FCC, FM, RCM Fluid group according to PED 2014/68/EU gas group 1, liquid group 1 Pressure device category according to PED

2014/68/EU

Article 4.3

The information provided in this data sheet contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice.