This technical specification document is for Type 3 Lettering and Striping for the California Department of Forestry and Fire Protection (CAL FIRE), prepared by the State of California General Services Department. The specification establishes minimum requirements for lettering and striping on Type 3 Wildland Fire Apparatus, detailing precise graphic design, placement, and material standards for vehicle exterior markings. The document provides comprehensive visual guidelines through 16 detailed figures showing exact placement of vehicle numbers, agency logos, striping, and reflective tape on various parts of the fire apparatus, including sides, doors, bumpers, roof, and rear panels.
The specification requires contractors to install graphics using 3M brand 680 series Scotchlite plus (or equivalent) reflective tape and CAL FIRE-provided exterior door shields. Specific requirements include a 6-inch white reflective side stripe, CAL FIRE cab door logo, "CAL FIRE" decals, 30-inch-tall black vinyl adhesive-backed agency identification numbers on the cab roof, and a 4-inch red reflective stripe along the interior of all compartment doors. The document references compliance with Federal Motor Vehicle Safety Standards (FMVSS) and National Fire Protection Agency (NFPA) standards 1900, 1901, and 1906, with final details to be discussed at a pre-construction conference.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_1-Specification_4210-TS-0253222-1_Type_3.pdf | ||
| Event_36181_Type_3_Fire_Apparatus.docx | DOCX document | |
| Event_36181_Type_3_Fire_Apparatus_-_Addendum_1.docx | DOCX document | |
| Attachment_1C_-_Specified_Alternative_Brand_Listing.xlsx | XLSX spreadsheet | |
| Question___Answer_Set__1.docx | DOCX document | |
| Attachment_3_-_Narrative_Response.docx | DOCX document | |
| Addendum_1_Cover_Sheet.docx | DOCX document | |
| Attachment_2_-_Cost_Worksheet.xlsx | XLSX spreadsheet | |
| Attachment_4_-_Customer_Reference_Form.docx | DOCX document | |
| Attachment_1A-Specification_4210-TS-0253222-2_EQ,_RP,_AVL.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
State of California Technical Specification
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
4210-TS-0253222-3
Grant, M Page 1 of 12 07/11/2025
Document Summary Detail Type Detail Event ID 0000036181 Commodity Type 3 Lettering and Striping Attachment (Exhibit) 1B Technical Specification 4210-TS-0253222-3 Specification Date July 11, 2025 Revision Level - Revision Date - Agency Name California Department of Forestry and Fire Protection (CAL FIRE)
Revision History Technical Spec Rev
Level Revision Date Author Summary of Changes
4210-TS-0253222-3 - - Michael Grant Initial Release
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 2 of 12 07/11/2025
Table of Contents Document Summary Revision History Table of Contents
1.0 SCOPE
2.0 APPLICABLE LAWS and INDUSTRY STANDARDS
2.1 Laws, Regulations, And Codes
2.2 Industry Standards
3.0 TECHNICAL REQUIREMENTS
3.1 General
3.2 Workmanship
4.0 EXTERIOR LETTERING and STRIPING REQUIREMENTS
4.1 Materials Supplied by Vendor
5.0 CAL FIRE TYPE 3 INFORMATIONAL PICTURES
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 3 of 12 07/11/2025
1.0 SCOPE
This specification establishes the minimum requirements for the Lettering and Striping pertaining to the Type 3 Wildland Fire Apparatus intended for use by personnel at the California Department of Forestry and Fire Protection (CAL FIRE).
2.0 APPLICABLE LAWS and INDUSTRY STANDARDS
The following standards, laws, regulations, and codes of the issue in effect on the date of the Invitation for Bid (IFB) form a part of this specification to the extent specified herein. Any applicable laws, regulations, codes, industry standards, or manufacturing standards, though not specifically cited, shall apply. Any referenced document is the current edition, unless otherwise stated, as of the date of the issuance of this specification.
Should a conflict arise between any of these standards and this specification CAL FIRE will determine as to which standard or specification will be in effect. Details regarding any conflicts between the specific standards and compliance will be finalized at the pre-construction conference or during the development process.
Any test equipment required, or expense incurred for the Certification Tests shall be borne by the Contractor supplying this equipment.
2.1 Laws, Regulations, And Codes
2.1.1 Federal Motor Vehicle Safety Standards (FMVSS)
2.2 Industry Standards
2.2.1 National Fire Protection Agency (NFPA) 1900, 1901 and 1906
3.0 TECHNICAL REQUIREMENTS
3.1 General
The Lettering and Striping shall be new, unused, and current production as specified in the solicitation at the line item description. The Lettering and Striping shall meet or exceed the requirements in the solicitation line item description. The Lettering and Striping be supplied with all equipment and accessories indicated as standard equipment in the manufacturer’s published literature or website.
The Lettering and Striping shall include all necessary equipment, be complete, and ready to use.
All parts not specifically mentioned which form part of the complete unit required for functionality shall be provided and shall conform in design, strength, quality of materials, and workmanship to the highest standards of engineering practices.
3.2 Workmanship
The Lettering and Striping, including any equipment and accessories, shall be a product of good workmanship. The Lettering and Striping shall be free from any defects that will affect appearance or serviceability; including, but not limited to, paint/metal free from scratches, securely fastened wiring, and free from obstructions of all correctly installed hardware.
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 4 of 12 07/11/2025
4.0 EXTERIOR LETTERING and STRIPING REQUIREMENTS
Under the direction of the CAL FIRE representative, the contractor shall install the CAL FIRE required graphics package on the vehicle exterior utilizing 3M brand 680 series Scotchlite plus (or equivalent) reflective tape and the CAL FIRE provided exterior door shields. In addition, a 4-inch red reflective stripe shall be installed along the lower inside wall of all compartment doors, including the cab doors.
Four (4) 30-inch-tall black vinyl adhesive backed agency identification numbers shall be installed on the cab roof. Final details shall be discussed during the pre-construction conference.
4.1 Materials Supplied by Vendor
Sides
• White reflective side stripe height 6 inches
• CAL FIRE cab door logo
• “CAL FIRE” decal
Rear
• “CAL FIRE” decal (center)
5.0 CAL FIRE TYPE 3 INFORMATIONAL PICTURES
Figure 1: Driver Side View
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 5 of 12 07/11/2025
Figure 2: Passenger Side View
Figure 3: Front Bumper Vehicle Number
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 6 of 12 07/11/2025
Figure 4: Fender Flare Striping
Figure 5: Front Door Striping and Logo
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 7 of 12 07/11/2025
Figure 6: Front Door Striping and Logo
Figure 7: Rear Door Striping and Vehicle Number
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 8 of 12 07/11/2025
Figure 8: Passenger Side Doors Striping, Badging, and Vehicle Number
Figure 9: Rear Side Doors Striping
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 9 of 12 07/11/2025
Figure 10: Rear Side Doors Striping
Figure 11: Side Equipment Doors Striping
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B 4210-
TS-0253222-3
Grant, M Page 10 of 12 07/11/2025
Figure 12: Side Equipment Doors Striping
Figure 13: Roof Vehicle Numbering
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 11 of 12 07/11/2025
Figure 14: Compartment and Discharge Valves Labeling
Figure 15: Rear Vehicle Numbering
Type 3 Lettering and Striping
Event ID 0000036181 Attachment 1B
Grant, M Page 12 of 12 07/11/2025
Figure 16: Rear View
| Document Summary |
| Revision History |
| Table of Contents |
| 1.0 SCOPE |
| 2.0 APPLICABLE LAWS and INDUSTRY STANDARDS |
| 2.1 Laws, Regulations, And Codes |
| 2.2 Industry Standards |
| 3.0 TECHNICAL REQUIREMENTS |
| 3.1 General |
| 3.2 Workmanship |
| 4.0 EXTERIOR LETTERING and STRIPING REQUIREMENTS |
| 4.1 Materials Supplied by Vendor |
5.0 CAL FIRE TYPE 3 INFORMATIONAL PICTURES
File details come from the government source that posted it. Updated .