ATTACHMENT 04 Section 01 32 23 Survey Layout and Data.pdf

PDF 292 KB Posted

Attached to
Ft. Sill JOC Job Order Contract
Solicitation number
W9124L21B0001
Issued by

View the file

Other files

File Type Posted
W9124L-21-B-0001 Abstract of Offers signed.pdf PDF
W9124L-21-B-0001 AMENDMENT 0002.pdf PDF
ATTACHMENT 21- 00 21 16 Coefficient Proposal Format 6-17-21.pdf PDF
ATTACHMENT 01 Section 01 00 00 General Requirements JOC - 6-1-21.pdf PDF
W9124L21B0001 Ammendment 0001Ft SILL JOC SOLICITATION POSTED 6-9-21.pdf PDF
ATTACHMENT 15 Section 01 78 00 Closeout Submittals.pdf PDF
ATTACHMENT 05 Section 01 33 00 Submittal Procedures.pdf PDF
ATTACHMENT 13 Section 01 70 00 Contract Closeout.pdf PDF
ATTACHMENT 20 Section 26 00 01 Fort Sill Electrical Requirements-revised Mar 16 2018 - ADG.pdf PDF
ATTACHMENT 09 Section 01 42 00 Referenced Specifications 6-1-21.pdf PDF
ATTACHMENT 08 Section 01 35 43 Environmental Procedures.pdf PDF
ATTACHMENT 16 Section 01 78 36 Warranty of Construction.pdf PDF
W9124L21B0001 Ft SILL JOC SOLICITATION.pdf PDF
ATTACHMENT 18 Section 02 81 00 Transportation and Disposal of Hazardous Materials.pdf PDF
ATTACHMENT 11 Section 01 57 19 Temporary Environmental Controls.pdf PDF
ATTACHMENT 02 Section 01 14 00 Work Restrictions.pdf PDF
ATTACHMENT 06 Section 01 35 26 Governmental Safety Requirements.pdf PDF
Attachment 23 - Bid Schedule.xlsx XLSX spreadsheet
ATTACHMENT 14 Section 01 74 19 Construction Waste Management and Disposal.pdf PDF
ATTACHMENT 22 Wage Determination OK20210043.pdf PDF
ATTACHMENT 19 Section 02 83 13 Lead Hazard.pdf PDF
ATTACHMENT 10 Section 01 45 00 QC For Minor Construction.pdf PDF
ATTACHMENT 07 Section 01 35 29 Health Safety and Emergency Response Procedures.pdf PDF
ATTACHMENT 21- 00 21 16 Coefficient Proposal Format.pdf PDF
ATTACHMENT 03 Section 01 32 00 Project Schedule.pdf PDF
ATTACHMENT 17 Section 02 41 00 Demolition.pdf PDF
ATTACHMENT 12 Section 01 57 20 Environmental Protection.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 01 32 23

SURVEY, LAYOUT, AND OTHER DATA

PART 1 - GENERAL:

1.1 REFERENCES: (Not Applicable)

PART 2 - PRODUCTS: (Not Applicable)

PART 3 - EXECUTION:

3.1 CONTRACTOR VERIFICATION OF CONTRACT SURVEY DATA

During the initial site layout and before existing site conditions are disturbed the Contractor shall verify, in writing, the basic survey data provided on the drawings or documents provided (if there are any deviations). Verification shall be from the contract drawings and shall include, as a minimum, the existing benchmark data provided and northings and eastings provided to ensure that the survey data adequately reflects existing conditions. The Contractor shall not proceed with construction until the survey verification is provided to the Contracting Officer's Authorized Representative. The Contractor shall refer to Contract Clauses, "Differing Site Conditions" and "Site Investigations and Conditions Affecting Work", for additional requirements.

3.2 CONSTRUCTION TOLERANCES

Construction horizontal and vertical layout shall not deviate from the allowable tolerances as shown in the table below.

Construction Tolerances Item Horizontal Vertical

Box Culverts +/- 0.10 ft. +/- 0.05 ft.

Bridge Substructures +/- 0.03 ft. +/- 0.03 ft.

Bridge Superstructures +/- 0.02 ft. +/- 0.02 ft.

Clearing and Grubbing Stakes +/- 1.00 ft. n/a

Construction Centerline Control Points +/- 0.05 ft. n/a

Construction Centerline Station Points +/- 0.10 ft. n/a

Curbs, Walks, and Bike Paths +/- 0.03 ft. +/- 0.02 ft.

Engineering Stationing +/- 1.00 ft. n/a

Grade Stakes - Roadway Subgrade +/- 0.20 ft. +/- 0.05 ft.

Grade Stakes - Top of Rock +/- 0.20 ft. +/- 0.03 ft.

All ACP Courses +/- 0.10 ft. +/- 0.02 ft.

Manholes, Inlets, and Culverts +/- 0.10 ft. +/- 0.03 ft.

PCC Pavement +/- 0.10 ft. +/- 0.02 ft.

Slope Stakes and References +/- 0.30 ft. +/- 0.10 ft.

Traffic Markings +/- 0.20 ft. n/a

Walls - Retaining, MSE, Sound, etc. +/- 0.10 ft. +/- 0.05 ft.

Wetland Mitigation Control Stakes +/- 0.20 ft. +/- 0.20 ft.

Luminaire and Signal Poles (incl. footings) +/- 0.20 ft. +/- 0.03 ft.

Storm Sewers +/- 0.02 ft. +/- 0.01 ft

Pipe Culverts +/- 0.10 ft +/- 0.02 ft

Structure Layout +/- 0.02 ft +/- 0.01 ft

Concrete Barriers +/- 0.02 ft +/- 0.01 ft

Electrical Installation +/- 0.02 ft +/- 0.01 ft

Supplemental Control Third Order Third Order

Note: Where tolerances differ from Building Codes, such as ACI, the stricter shall apply.