Attachment 01 - Part 1 Plans Construct Hydrazine PSTE172020.pdf
PDF 13 MB Posted
- Attached to
- Construct Hydrazine Facility
- Solicitation number
- W50S95-22-B-0001
- Issued by
-
Department of the Army National Guard
About this file
This document provides details for a solicitation to construct a new Hydrazine Storage Facility. The South Carolina Air National Guard intends to award a single firm fixed-price contract for construction services including erecting a new facility, site work, utilities, and fire protection systems. The scope of work is described in an attachment to plans and specifications. The project value is between $500,000 and $1,000,000 and has a performance period of 180 days. The solicitation is set aside exclusively for small businesses with a size standard of $39.5 million defined by NAICS code 236220. Interested offerors must register on SAM.gov and check betaSAM.gov for solicitation documents and any amendments, with the pre-bid conference on June 14th and bids due June 28th.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I N D E X O F D R A W I N G S
C :\r vt \2
8\
-0 0-
G _J as on
.S ea gl e.
rv t
6/
/2
9:
:0
A
M
SHEET # DESCRIPTION
SERIES 13 - MECHANICAL
M-001 MECHANICAL LEGEND, NOTES, AND ABBREVIATIONS
M-101 MECHANICAL PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
SERIES 14 - PLUMBING
P-001 PLUMBING LEGEND, NOTES, AND ABBREVIATIONS
P-101 PLUMBING PLANS
P-401 DOMESTIC WATER RISER DIAGRAM
P-402 RISER DIAGRAMS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
SERIES 15 - FIRE PROTECTION
FA001 FIRE PROTECTION LEGEND, NOTES, AND ABBREVIATIONS
FA101 FIRE ALARM AND MASS NOTIFICATION PLAN
FA601 FIRE ALARM SEQUENCE OF OPERATION & RISER DIAGRAM
FX101 FIRE PROTECTION PLAN
FX501 FIRE PROTECTION DETAILS
SERIES 16 - ELECTRICAL
E-001 ELECTRICAL LEGEND AND NOTES
E-101 ELECTRICAL SITE PLAN
E-102 POWER PLANS
E-103 LIGHTING PLAN
E-104 ELECTRICAL SCHEDULES
E-105 ELECTRICAL DETAILS GROUNDING
E-106 ELECTRICAL DETAILS
SHEET # DESCRIPTION
SERIES 00 - GENERAL
G-000 COVER SHEET
G-001 ABBREVIATIONS
G-002 GENERAL LEGEND
G-003 CODE ANALYSIS
G-004 LIFE SAFETY PLAN
G-005 CODE COMPLIANCE SITE PLAN
SERIES 05 - CIVIL
C-000 CIVIL LEGEND
C-001 OVERALL SITE PLAN
C-002 SITE DEMOLITION PLAN
C-003 CIVIL EROSION CONTROL PLAN
C-004 CIVIL GRADING AND DRAINAGE PLAN
C-005 CIVIL UTILITY PLAN
C-006 CIVIL EROSION CONTROL DETAILS
C-007 CIVIL EROSION CONTROL DETAILS
C-008 CIVIL EROSION CONTROL DETAILS
C-009 CIVIL EROSION CONTROL DETAILS
SERIES 08 - STRUCTURAL
S-100 STRUCTURAL GENERAL NOTES
S-101 STRUCTURAL PLANS
S-301 STRUCTURAL SECTIONS
S-500 STRUCTURAL STANDARD DETAILS
S-501 STRUCTURAL STANDARD DETAILS
S-502 STRUCTURAL STANDARD DETAILS
SERIES 09 - ARCHITECTURAL
A-101 FLOOR PLAN
A-102 ROOF PLAN AND DETAILS
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-302 WALL SECTIONS & DETAILS
A-501 SCHEDULES & DETAILS
PROJECT
LOCATION
COLUMBIA
SOUTH CAROLINA AIR NATIONAL GUARD
MCENTIRE JOINT NAVAL GUARD BASE
CONSTRUCT HYDRAZINE FACILITY
169th AIRLIFT WING
EASTOVER, SC
CONTRACT NO.: W9133L-15-D-0004
TASK ORDER NO.: W912QG-18-F-0040
PN: PSTE172020
B-2 DESIGN SUBMISSION
JUNE 2019
EASTOVER
TOP OF BOLT, TOP OF BANK,
TOP OF BEAM, TOP OF BERM
TOP OF CURB, TOP OF CONCRETE
TOP OF DUCT
TOP OF FOOTING
TOP OF GRATING
TOLERANCE, TOP OF LEDGER
TOP OF MASONRY
TOP OF PLATE
TOPOGRAPHY
TOP OF SLAB, TOP OF STEEL,
TOE OF SLOPE
TOP OF WALL
TOILET PARTITION, TELEPHONE POLE,
TOE PLATE, TRAP PRIMER
TOILET PAPER DISPENSER
TOPPING, THROUGH PLATE GIRDER
TRANSOM
TRANSITION
TRENCH DRAIN
TYPICAL
URINAL
UNDERGROUND
ULTIMATE
UNFINISHED
UNLESS NOTED OTHERWISE
UTILITY
VENT, VELOCITY, VOLT
VOLT AMPERE
VACUUM
VARNISH, VARIABLE,
VOLT AMPERES REACTIVE
VAPOR BARRIER, VINYL BASE,
VALVE BOX
VERTICAL CURVE
VITRIFIED CLAY PIPE
VINYL COMPOSITION TILE,
VERTICAL CENTERLINE
VELOCITY
VENTILATION
VERTICAL
VERTICAL REINFORCING
VERTICAL GRAIN
VERIFY IN FIELD
VINYL
VOLUME
VERTICAL POINT OF CURVATURE
VERTICAL POINT OF INTERSECTION
VERTICAL POINT OF TANGENCY
VERSUS, VAPOR SEAL
VENT THROUGH ROOF
VINYL WALL COVERING
WITH
WITHOUT
WATT, WEST, WIDE, WINDOW, WIRE,
WIDE FLANGE BEAM
WOOD BASE
WATER CLOSET, WATER COLUMN
WOOD, WIDTH
WIDE FLANGE, WASH FOUNTAIN
WIRE GLASS, WATER GAGE
WALL HYDRANT, WEEP HOLE
WROUGHT IRON
WATER LEVEL
WELDED
WIRE MESH
WEATHERPROOF
WATERSTOP, WATER SURFACE
WAINSCOT
WEIGHT, WATER TIGHT
WATERPROOF, WORKING POINT
WELDED WIRE FABRIC
EXPLOSION-PROOF
EXTRA STRONG
CROSS SECTION
DOUBLE EXTRA STRONG
YARD HYDRANT
YIELD STRENGTH
TOB
TOC
TOD
TOF
TOG
TOL
TOM
TOP
TOPO
TOS
TOW
TP
TPD
TPG
TR
TRANS
TRD
TYP
U
UG
ULT
UNFN
UNO
UTIL
V
VA
VAC
VAR
VB
VC
VCP
VCT
VEL
VENT
VERT
VERTS
VG
VIF
VIN
VOL
VPC
VPI
VPT
VS
VTR
VWC
W/
W/O
W
WB
WC
WD
WF
WG
WH
WI
WL
WLD
WM
WP
WS
WSCT
WT
WTHP
WWF
XP
XS
XSECT
XXS
YH
YS
REMOVE AND REPLACE
REMOVE AND SALVAGE
RADIUS, REGISTER, RISER
RETURN AIR
RESILIENT BASE, ROCK BERM
RECEPTACLE
ROOF DRAIN
RECESS
RECEIVED
RECTANGULAR
REDUCER
REFERENCE
REINFORCING
REMOVE
REQUIRED
RESILIENT
RETAINING, RETURN
REVISION, REVERSE
RESILIENT FLOORING
ROOFING
REFLECTED, REFLECTOR
ROUGH
RIGID GALVANIZED STEEL
PVC COATED RGS
RELIEF HOOD, RIGHT HAND,
RELATIVE HUMIDITY
REQUIRED LAP
RELIEF AIR
ROUND
RUNNING
ROUGH OPENING
RIGHT-OF-WAY
REVOLUTIONS PER MINUTE
RAILROAD
ROCK SLOPE PROTECTION
RIGHT
RESILIENT VINYL TILE
READY
SOUTH, SINK
SUPPLY AIR
SOUND-ABSORBING MASONRY UNIT
SANITARY
SPLASH BLOCK
SOLID CORE
SCHEDULE
SCHEMATIC
SCREEN
STEEL/ALUMINUM EDGE
SECONDARY, SECONDS
SECTION
SEPARATE
SQUARE FOOT, SILT FENCE
SHEET GLASS, SEALANT GROOVE
SHOWER
SHEET
SHEATHING
SILENCE
SIMILAR
SLAB JOINT
SLOPE, STEEL LINTEL
SLOTTED
SLEEVE
SEAMLESS
SLAB ON GRADE
SOUNDPROOF, STANDPIPE
SPACING
SPECIFICATION
SUPPLY
SINGLE POLE SINGLE THROW
SET POINT
SQUARE
SHORT RADIUS
SERVICE SINK
STAINLESS STEEL
STREET
STATION
STANDARD
STIFFENER
STIRRUP
STEEL
STORAGE
STRUCTURAL, STRAIGHT
SUBSTITUTE
SUCTION
SUSPENDED
SQUARE YARD
SYMBOL
SYMMETRICAL
SYNTHETIC
SYSTEM
TOP AND BOTTOM
TONGUE AND GROOVE
TILE, TREAD
TOILET ACCESSORY, TEMPERED AIR
TANGENT
TEMPORARY BENCHMARK
TEMPORARY CONSTRUCTION EASEMENT
TROWELED EPOXY FLOORING
TEMPORARY, TEMPERATURE
THREAD
THICK
THRESHOLD
TACK BOARD
R&R
R&S
R
RA
RB
RCPT
RD
REC
RECD
RECT
RED
REF
REINF
REM
REQD
RESIL
RET
REV
RF
RFG
RFL
RGH
RGS
RGS-PVC
RH
RL
RLFA
RND
RNG
RO
ROW
RPM
RR
RSP
RT
RVT
RY
S
SA
SAMU
SAN
SB
SC
SCH
SCHEM
SCN
SE
SEC
SECT
SEP
SF
SG
SH
SHT
SHTG
SIL
SIM
SJ
SL
SLTD
SLV
SMLS
SOG
SP
SPA
SPEC
SPLY
SPST
SPT
SQ
SR
SS
SST
ST
STA
STD
STIF
STIR
STL
STOR
STR
SUB
SUC
SUSP
SY
SYM
SYMM
SYN
SYS
T&B
T&G
T
TA
TAN
TBM
TCE
TEF
TEMP
THD
THK
THRESH
TKBD
NORTH, NEUTRAL
NOT APPLICABLE
NATURAL, NATIONAL
NORMALLY CLOSED
NEGATIVE
NEAR FACE, NON-FUSED
NOT IN CONTRACT
NORMALLY OPEN, NUMBER
NOMINAL
NOMINAL PIPE SIZE
NATIONAL PIPE THREAD
NEAR SIDE
NOT TO SCALE
NORMAL WATER LEVEL
OUT TO OUT
OUTSIDE AIR, OVERALL
ON CENTER
OVER CURRENT PROTECTION DEVICE
OUTSIDE DIAMETER
OPEN END DUCT
OUTSIDE FACE, OFFICE FURNISHING
OWNER FURNISHED CONTRACTOR
INSTALLED
OWNER FURNISHED OWNER INSTALLED
ORIGINAL GROUND
OVERHEAD
OPENING
OPPOSITE
OPTIONAL
OUTSIDE RADIUS
OVERFLOW ROOF DRAIN
ORIGINAL
OVERFLOW
OVERHANG
OUNCE
PAINT
PUBLIC ADDRESS
PARALLEL, PARAPET
PANIC BAR, PULL BOX
PARTICLE BOARD
POINT OF CURVE, PIECE, PRECAST
POINT OF COMPOUND CURVATURE
POUNDS PER CUBIC FOOT
PERCENT
PLAIN END
PEDESTAL
PENETRATION
PERFORATED
PERMANENT
PERPENDICULAR
POWER FACTOR
PREFACED MASONRY UNIT
PHASE
POINT OF INTERSECTION
PACKAGE
PLATE, PROPERTY LINE,
PRECAST LINTEL
PLASTER
PLATFORM
PLUMBING
POUNDS PER LINEAR FOOT
PNEUMATIC
POLISH
POSITIVE, POSITION
POLYPROPYLENE, POWER POLE
POINT OF REVERSE CURVATURE
PREFINISHED
PREFABRICATED
PRELIMINARY
PREPARE
PRESSURE
PRIMARY
PROPERTY, PROPOSED
PROTECTION
PIPE SUPPORT
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH ABSOLUTE
POUNDS PER SQUARE INCH GAGE
PRESTRESSED
POINT, POINT OF TANGENCY
PARTITION
POLYVINYL CHLORIDE, POINT OF
VERTICAL CURVE
PAVEMENT
PLYWOOD
PLYWOOD WEB JOIST
PIEZOMETER
RATE OF FLOW
QUARRY TILE
QUARTER
QUANTITY
QUALITY
N
NA
NAT
NC
NEG
NF
NIC
NO
NOM
NPS
NPT
NS
NTS
NWL
O TO O
OA
OC
OCPD
OD
OED
OF
OFCI
OFOI
OG
OH
OPNG
OPP
OPT
OR
ORD
ORIG
OVFL
OVHG
OZ
P
PA
PAR
PB
PBD
PC
PCC
PCF
PCT
PE
PED
PEN
PERF
PERM
PERP
PF
PFMU
PH
PI
PKG
PL
PLAS
PLAT
PLBG
PLF
PNEU
POL
POS
PP
PRC
PREF
PREFAB
PRELIM
PREP
PRES
PRI
PROP
PROT
PS
PSF
PSI
PSIA
PSIG
PST
PT
PTN
PVC
PVMT
PWD
PWJ
PZ
Q
QT
QTR
QTY
QUAL
ID
IE
IF
IH
IMP
IN
INC
INF
INSTR
INSUL
INT
INTR
INV
IPS
IPT
IR
IRR
ISO
JB
JCT
JF
JST
JT
K
KB
KCMIL
KD
KO
KSI
KW
L
LAD
LAM
LATL
LB
LCTB
LDG
LDR
LE
LF
LG
LH
LIN
LIQ
LLH
LLV
LMLU
LNG
LOC
LP
LPS
LR
LT
LTD
LTG
LTL
LTNG
LV
LVL
LVR
LW
LWC
LWL
MA
MACH
MAINT
MAN
MATL
MAX
MB
MBR
MC
MCB
MCJ
MDMJ
MECH
MED
MFR
MH
MIN
MIR
MISC
MJ
ML
MLO
MMB
MO
MOD
MON
MPT
MRGWB
MS
MSL
MT
MU
MULL
MV
MW
INSIDE DIAMETER, INTERIOR DIMENSION
INVERT ELEVATION, FOR EXAMPLE
INSIDE FACE
INTAKE HOOD
IMPACT
INCH
INCLUDE, INCANDESCENT
INFLUENT
INSTRUMENTATION
INSULATION
INTERIOR, INTERSECTION
INTERMEDIATE, INTERIOR
INVERT
IRON PIPE SIZE
INTERNAL PIPE THREAD
INSIDE RADIUS, IRON ROD
IRRIGATION
ISOMETRIC
JUNCTION BOX
JUNCTION
JOINT FILLER
JOIST
JOINT
KIP
KNEE BRACE
THOUSAND CIRCULAR MILS
KNOCK DOWN
KNOCK OUT
KIPS PER SQUARE INCH
KILOWATT
ANGLE, LENGTH, LAVATORY, LINTEL
LADDER
LAMINATE
LATERAL
LAG BOLT, POUND
LIQUID CHALK AND TACK BOARD
LANDING
LEADER
LIFTING EYE
LINEAR FOOT
LONG
LEFT HAND
LINEAR
LIQUID
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LIQUID MARKER LECTURE UNIT
LONGITUDINAL
LOCATION
LOW POINT
LOW-PRESSURE SODIUM
LONG RADIUS
LEFT
LIMITED
LIGHTING
LINTEL
LIGHTNING
LOW VOLTAGE
LAMINATED VENEER LUMBER
LOUVER
LIGHTWEIGHT
LIGHTWEIGHT CONCRETE
LOW WATER LEVEL
MIXED AIR
MACHINED
MAINTENANCE
MANUAL
MATERIAL
MAXIMUM
MACHINE BOLT
MEMBER
MECHANICAL CONTRACTOR,
MECHANICAL COUPLING,
MOMENT CONNECTION
METAL CORNER BEAD
MASONRY CONTROL JOINT
MODIFIED DOUBLE MECHANICAL JOINT
MECHANICAL
MEDIUM
MANUFACTURER
MANHOLE, METAL HALIDE
MINIMUM
MIRROR
MISCELLANEOUS
MECHANICAL JOINT
MASONRY LINTEL
MAIN LUGS ONLY
MEMBRANE
MASONRY OPENING
MODULAR, MODIFY
MONUMENT
MALE PIPE THREAD
MOISTURE-RESISTANT
GYPSUM WALLBOARD
MOP SINK
MEAN SEA LEVEL
MOUNT
MASONRY UNIT
MULLION
MEDIUM VOLTAGE
MONITORING WELL
F TO F
F&B
FAB
FB
FBD
FBG
FBM
FBO
FC
FCA
FD
FDC
FDR
FDTN
FE
FEC
FES
FEXT
FF
FG
FH
FIG
FIN
FJT
FL
FLEX
FLG
FLOR
FLR
FLS
FN
FO
FOB
FOC
FOF
FOM
FOS
FOT
FPT
FR
FRP
FRTM
FS
FT
FTG
FUR
FURN
FUT
FV
FW
FWD
FWE
FXTR
G
GA
GAL
GALV
GB
GC
GD
GEN
GFCI
GFMU
GG
GJ
GL
GLB
GND
GP
GR
GRTG
GSB
GT
GVL
GW
GWB
GYP
H
HB
HBD
HC
HD
HDR
HDW
HEX
HGR
HH
HID
HM
HORIZ
HP
HPC
HPS
HPT
HR
HS
HSS
HT
HTG
HV
HVAC
HWD
HWL
HYD
HZ
FACE TO FACE
FACE AND BYPASS
FABRICATE
FLOOR BEAM
FIBERBOARD
FIBERGLASS
BOARD FOOT MEASURE
FURNISHED BY OWNER
FLUSHING CONNECTION
FLANGED COUPLING ADAPTER
FLOOR DRAIN
FLEXIBLE DUCT CONNECTION
FEEDER
FOUNDATION
FLANGED END
FIRE EXTINGUISHER CABINET
FLARED END SECTION
FIRE EXTINGUISHER
FAR FACE, FACTORY FINISH, FLAT FACE
FINISHED GRADE
FIRE HYDRANT
FIGURE
FINISH
FLUSH JOINT
FLOW, FLOW LINE
FLEXIBLE
FLANGE
FLUORESCENT
FLOOR
FLASHING, FLUSH
FENCE
FINISHED OPENING
FLAT ON BOTTOM
FACE OF CONCRETE, FACE OF CURB
FACE OF FINISH
FACE OF MASONRY
FACE OF STUDS
FLAT ON TOP
FEMALE PIPE THREAD
FRAME
FIBERGLASS REINFORCED PLASTIC
FIRE RETARDANT TREATED MATERIAL
FLOOR SINK, FAR SIDE
FEET, FOOT
FOOTING, FITTING
FURRED, FURRING
FURNITURE, FURNISH
FUTURE
FACE VELOCITY
FIELD WELD, FIRE WALL
FORWARD
FURNISHED WITH EQUIPMENT
FIXTURE
GRILLE, GROUND
GAGE (METAL THICKNESS)
GALLON
GALVANIZED
GRAB BAR, GRADE BREAK
GROOVED COUPLING
GUARD
GENERAL
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FACE MASONRY UNIT
GUTTER GRADE
GROOVED JOINT
GLASS
GLASS BLOCK, GLULAM BEAM
GROUND
GUY POLE
GRADE
GRATING
GYPSUM SHEATHING BOARD
GREASE TRAP
GRAVEL
GUY WIRE
GYPSUM WALLBOARD
GYPSUM HARDBOARD
HIGH
HOSE BIBB
HARDBOARD
HANDICAPPED, HOLLOW CORE, HORIZONTAL
CURVE, HORIZONTAL CENTERLINE
HEAD, HOT DIP
HEADER
HARDWARE
HEXAGONAL
HANGER
HANDHOLE
HIGH-INTENSITY DISCHARGE
HOLLOW METAL
HORIZONTAL
HIGH POINT, HORSEPOWER
HORIZONTAL POINT OF CURVATURE
HIGH-PRESSURE SODIUM
HORIZONTAL POINT OF TANGENCY
HOSE REEL, HOUR
HEADED STUD, HIGH STRENGTH
HOLLOW STRUCTURAL SHAPE
HEIGHT
HEATING
HIGH VOLTAGE
HEATING, VENTILATING AND
AIR CONDITIONING
HARDWOOD
HIGH WATER LEVEL
HYDRAULIC
HERTZ, CYCLES PER SECOND
CLKG
CLR
CMH
CMP
CMU
CO
COL
COM
COMB
COMM
COMP
CON
CONC
CONN
CONST
CONT
COOR
CORR
CP
CPLG
CRL
CSC
CSK
CSS
CT
CTJ
CTR
CTRL
CVT
CU
CW
CY
d
D
DB
DBA
DBL
DC
DEG
DEG C
DEG F
DEMO
DEP
DEPT
DET
DI
DIA
DIAG
DIFF
DIM
DISCH
DIST
DIV
DL
DMJ
DMPF
DN
DO
DP
DPDT
DPST
DS
DT
DUP
DWG
DWL
DWR
E
EA
EC
ECC
ED
EDB
EE
EF
EFF
EHH
EIFS
EJ
EL
ELEC
EMBD
EMER
EMH
ENCL
ENGR
ENTR
EOP
EQ
EQUIP
EQUIV
ES
ESEW
EST
EW
EWC
EWEF
EWTB
EXC
EXH
EXP
EXST
EXT
CAULKING
CLEAR
COMMUNICATION MANHOLE
CORRUGATED METAL PIPE
CONCRETE MASONRY UNIT
CLEANOUT, CONCRETE OPENING
COLUMN
COMMON
COMBINATION
COMMUNICATION
COMPOSITION, COMPRESSIBLE,
COMPOSITE
CONCENTRIC
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
COORDINATE
CORROSIVE, CORRUGATED
CHECKER PLATE, CONTROL POINT
COUPLING
CORROSION-RESISTANT LINING
COMPRESSION SLEEVE COUPLING
COUNTERSINK
CLINIC SERVICE SINK
CERAMIC TILE
CONTRACTION JOINT
CENTER
CONTROL
CULVERT
COPPER, CUBIC
CLOCKWISE
CUBIC YARD
PENNY (NAIL MEASURE)
DEEP, DIFFUSER, DRAIN
DUCT BANK, DECIBEL, DRY BULB
DEFORMED BAR ANCHOR
DOUBLE
DIRECT CURRENT
DEGREE
DEGREE CENTIGRADE
DEGREE FAHRENHEIT
DEMOLITION
DEPRESSED
DEPARTMENT
DETAIL
DROP INLET, DUCTILE IRON, DIGITAL INPUT
DIAMETER
DIAGONAL, DIAGRAM
DIFFERENTIAL, DIFFERENCE
DIMENSION
DISCHARGE
DISTANCE, DISTRIBUTION
DIVISION
DEAD LOAD
DOUBLE MECHANICAL JOINT
DAMP PROOFING
DOWN
DISSOLVED OXYGEN, DIGITAL OUTPUT, DITTO
DEPTH
DOUBLE POLE, DOUBLE THROW
DOUBLE POLE, SINGLE THROW
DOWN SPOUT
DOUBLE TEE, DRIP TRAP ASSEMBLY
DUPLICATE
DRAWING
DOWEL
DRAWER
EAST
EACH, EXHAUST AIR
ELECTRICAL CONTRACTOR
ECCENTRIC
EQUIPMENT DRAIN
ELECTRICAL DUCT BANK
EACH END
EACH FACE
EFFLUENT, EFFICIENCY
ELECTRICAL HANDHOLE
EXTERIOR INSULATION &
FINISH SYSTEM
EXPANSION JOINT
ELBOW, ELEVATION
ELECTRICAL
EMBEDDED
EMERGENCY
ELECTRICAL MANHOLE
ENCLOSURE
ENGINEER
ENTRANCE
EDGE OF PAVEMENT
EQUAL
EQUIPMENT
EQUIVALENT
EACH SIDE, EQUAL SPACE,
EMERGENCY SHOWER
EMERGENCY SHOWER AND EYE WASH
ESTIMATE
EACH WAY, EMERGENCY
EYE/FACE WASH
ELECTRIC WATER COOLER
EACH WAY, EACH FACE
EACH WAY, TOP AND BOTTOM
EXCAVATION
EXHAUST
EXPANSION, EXPOSED
EXISTING
EXTERIOR, EXTERNAL, EXTENSION
A/C
A/E
A
AB
ABAN
ABC
ABT
AC
ACK
ACP
ACST
AD
ADDL
ADH
ADJ
AF
AFF
AFG
AGGR
AI
AIC
ALIG
ALT
ALUM
AM
AMB
ANC
AO
AP
APRX
APVD
ARCH
ASSY
AT
ATC
ATM
AUTO
AUX
AVE
AVG
AWG
AWT
B TO B
BAL
BBD
BC
BD
BE
BF
BITUM
BKG
BL
BLDG
BLK
BLKG
BM
BOC
BOD
BOG
BOL
BOP
BOR
BOT
BOU
BP
BRG
BRGP
BRKT
BS
BTU
BTW
BTWLD
BU
BUR
BW
BYP
CTOC
C&G
C
CAB
CAP
CAT
CAV
CB
CCB
CCW
CDF
CE
CER
CF
CFL
CHBD
CHD
CHFR
CHH
CI
CIP
CIPB
CIRC
CJ
CKT
CL
CLG
AIR CONDITIONING
ARCHITECT/ENGINEER
AMPERE
ANCHOR BOLT
ABANDON
AGGREGATE BASE COURSE
ABOUT
ALTERNATING CURRENT
ACKNOWLEDGE
ACOUSTIC CEILING PANEL,
ASPHALTIC CONCRETE PAVEMENT
ACOUSTIC
ADDENDUM, AREA DRAIN
ADDITIONAL
ADHESIVE
ADJUSTABLE, ADJACENT
AMP FRAME, AMP FUSE
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
AGGREGATE
AREA INLET, ANALOG INPUT
AMPS INTERRUPTING CAPACITY
ALIGNMENT
ALTERNATE, ALTITUDE
ALUMINUM
ACOUSTICAL MATERIAL
AMBIENT
ANCHOR
ANALOG OUTPUT
ACCESS PANEL
APPROXIMATE
APPROVED
ARCHITECTURAL
ASSEMBLY
ACOUSTICAL TILE, AMP TRIP
ACOUSTICAL TILE CEILING
ATMOSPHERE
AUTOMATIC
AUXILIARY
AVENUE
AVERAGE
AMERICAN WIRE GAGE
ACOUSTICAL WALL TILE
BACK TO BACK
BALANCE
BULLETIN BOARD
BASE CABINET, BOTTOM CHORD,
BOLT CENTER, BOLT CIRCLE
BOARD
BOTH ENDS, BELL END
BOTH FACES, BOTTOM FACE,
BLIND FLANGE, BOARD FEET
BITUMINOUS
BACKING
BASE LINE
BUILDING
BLOCK
BLOCKING
BENCHMARK, BEAM
BACK OF CURB
BOTTOM OF DUCT
BOTTOM OF GRILLE
BOTTOM OF LOUVER, BOLLARD
BOTTOM OF PIPE
BOTTOM OF REGISTER
BOTTOM
BOTTOM OF UNIT
BASE PLATE
BEARING
BEARING PLATE
BRACKET
BOTH SIDES
BRITISH THERMAL UNIT
BETWEEN
BUTT WELD
BELL UP, BUILT-UP
BUILT-UP ROOFING
BOTH WAYS
BYPASS
CENTER TO CENTER
CURB AND GUTTER
CHANNEL SHAPE, CENTIGRADE, CONDUIT
CABINET
CAPACITY
CATALOG, CATALOGIORY
CAVITY
CATCH BASIN
CONCRETE BLOCK
COUNTER CLOCKWISE
CONTROLLED-DENSITY FILL
CONCRETE EDGE
CERAMIC
CUBIC FEET (FOOT)
COUNTER FLASHING
CHALKBOARD
CHORD
CHAMFER
COMMUNICATION HANDHOLE
CURB INLET
CAST-IN-PLACE
CONCRETE INTERLOCKING PAVER
BALLAST
CIRCULATION, CIRCULAR
CONSTRUCTION JOINT
CIRCUIT
CENTERLINE, CLASS, CLOSE
CEILING
GENERAL NOTES:
THESE ABBREVIATIONS APPLY TO THE ENTIRE SET
OF CONTRACT DRAWINGS.
1.
LISTING OF ABBREVIATIONS DOES NOT IMPLY
THAT ALL ABBREVIATIONS ARE USED IN THE
CONTRACT DRAWINGS.
2.
ABBREVIATIONS SHOWN ON THIS SHEET INCLUDE
VARIATIONS OF A WORD. FOR EXAMPLE, "MOD" MAY
MEAN MODIFY OR MODIFICATION, "INC" MAY MEAN
INCLUDED OR INCLUDING, AND "REINF" MAY MEAN
REINFORCE OR REINFORCING.
3.
SEE INSTRUMENTATION AND GENERAL LEGEND
SHEETS FOR PROJECT-SPECIFIC EQUIPMENT AND
PIPING SYSTEM ABBREVIATIONS.
4.
S O
UT
H
A
NI
LORAC
C E R T I
AU T
HO
R
C
ATE OF
I T I
A Z
O N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F I
NONE
PROJECT MANAGER
0 1" 2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET CONTRACT #: W912QG-18-F-0040
ANG PROJECT #: PSTE172020
HDR PROJECT #: 10136847
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
MCENTIRE JOINT NATIONAL GUARD BASE
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
C rv t\
\1
-0
-G
J a s o n .S e a g le .r v t
/2
/2
:2
:0
A M
G-001
NICK OVERBY
10136847-00-G.rvt
ABBREVIATIONS
JUNE 2019 B-2 DESIGN SUBMISSION
X
X
X
X
XXX
X
ROOM
NAME
XX-XX
EQUIPMENT IDENTIFICATION
ALTERNATIVE 2
ALTERNATIVE 1
PIPING
GENERAL NOTES:
SHEET TYPE DESIGNATOR
DISCIPLINE DESIGNATOR & DISCIPLINE ORDER
EXAMPLE
ARCHITECTURAL
KEY NOTE DESIGNATION
PLAN TITLE
SECTION CUT MARKER
DETAIL MARKER
MULTIPLE ELEVATION OR PHOTO MARKER
DETAIL MARKER
SECTION TITLE
ELEVATION TITLE
DETAIL TITLE
FULL BUILDING SECTION CUT MARKER
1/4" = 1'-0"
X
XXX 3/8" = 1'-0"
XXX
XXXXXX
X
XXX 1/4" = 1'-0"
X
XXX
X
XXX 3" = 1'-0"
A
EQUIPMENT NUMBER
PUMP 23
INDICATES PUMP
EXAMPLEFIGURE
PUMP 23
BUILDING 20
INDICATES PUMP
EXAMPLEFIGURE
36"LINE SIZE
PLANT EFFLUENTSERVICE
EXAMPLE36"-PLEFIGURE
NPWP2023
NPWP-23
GRAVITY THICKENER ARCHITECTURAL SECTION, DRAWING 01
GENERAL (SYMBOLS, LEGENDS)
PLANS
ELEVATIONS
SECTIONS
LARGE SCALE VIEWS
DETAILS
SCHEDULES AND DIAGRAMS
PROFILES
3D REPRESENTATIONS
GENERAL
SURVEYING/MAPPING
CIVIL
STRUCTURAL
ARCHITECTURAL
MECHANICAL (HVAC)
PLUMBING
ELECTRICAL
G V C S A M P E
SERVICE
ABBREVIATION
EQUIPMENT
ABBREVIATION
BUILDING
OR
STRUCTURE
NUMBER
EQUIPMENT NUMBER
INDICATES
NON-POTABLE WATER
INDICATES
NON-POTABLE WATER
SERVICE
ABBREVIATION
EQUIPMENT
ABBREVIATION
KEY NOTE NUMBER
LOUVER
WINDOW TYPE
WALL TYPE
COLUMN GRID LINE
ROOM NUMBER
DOOR NUMBER
ACCESSORY, FURNITURE,
AND MISCELLANEOUS
EQUIPMENT IDENTIFIER
ARROW INDICATES
DIRECTION OF PLAN
NORTH
4-HOUR FIRE RATED WALL
3-HOUR FIRE RATED WALL
2-HOUR FIRE RATED WALL
1-HOUR FIRE RATED WALL
COLUMN GRID LINE/CENTERLINE
FOR REFERENCING DETAILS BOUND IN
SPECIFICATIONS OR SEPARATE VOLUME.
SHEET WHERE SECTION
IS LOCATED
SHEET WHERE SECTION
VIEW IS FIRST CUT *
SHEET WHERE DETAIL
IS LOCATED *
ELEVATION
IDENTIFICATION NUMBER
SHEET WHERE POINT OF VIEW
MARKER CAN BE FOUND *
* EXCEPTIONS WHERE THE SHEET NUMBER IS REPLACED BY A DASH (-).
1) FOR COMMON DETAILS, SECTIONS, ELEVATIONS OR DETAILS
THAT ARE CUT OR CALLED OUT ON MULTIPLE SHEETS.
2) SECTIONS, ELEVATIONS OR DETAILS THAT ARE LOCATED ON THE
SAME SHEET THEY ARE CUT OR CALLED OUT ON.
ARROW INDICATES POINT OF
VIEW ELEVATION
INDICATES SHEET WHERE
ELEVATION IS LOCATED
FOR REFERENCING DETAILS INCLUDED IN DRAWING SET.
X
XX
X
SECTION LETTER
FLAG INDICATES DIRECTION
OF SECTION CUT
SECTION LETTER
DETAIL NUMBER
SHEET WHERE DETAIL
IS LOCATED *
DETAIL NUMBER
ELEVATION NUMBER
SHEET WHERE
SECTION IS LOCATED
SECTION LETTER
TARGET ELEVATION
ARROW INDICATES
DIRECTION OF SECTION
CUT
IDENTIFICATION SYMBOLOGY SHEET NAMING CONVENTION
GENERAL LINE SYMBOLOGY
GENERAL SYMBOLOGY
PLAN
SECTION
DETAIL
ELEVATIONX
XXX
X
XXX
MATERIALS IN PLAN/SECTION
BRICK MASONRY (PLAN AND/OR SECTION)
GROUT (SECTION)
DEMOLITION (PLAN AND/OR SECTION)
CONCRETE (PLAN AND/OR SECTION)
GRANULAR FILL (SECTION)
EARTH (SECTION)
BATT INSULATION (SECTION)
WOOD - CONTINUOUS (SECTION)
RIGID INSULATION (SECTION)
WOOD - BLOCKING (SECTION)
GYPSUM BOARD (SECTION)
CONCRETE MASONRY (PLAN
AND/OR SECTION)
X
XXX
BUILDING OR AREA 02
SHEET TYPE DESIGNATOR
SHEET NUMBER
DISCIPLINE DESIGNATOR
BUILDING OR AREA DESIGNATION
EXAMPLE
0 2
A
0 1
0 2 A 3 0 1
ARCHITECTURAL
SECTIONS
SHEET 01
SINGLE ELEVATION OR PHOTO MARKER
X
XXX
X
XXX
ARROW INDICATES
POINT OF VIEW
SHEET WHERE ELEVATION
IS LOCATED *
INTERIOR EXTERIOR
ELEVATION NUMBER
NORTH ARROW
THIS IS A STANDARD SHEET SHOWING
COMMON SYMBOLOGY. ALL SYMBOLS ARE
NOT NECESSARILY USED ON THIS PROJECT.
SCREENING OR SHADING OF WORK IS USED
TO INDICATE EXISTING COMPONENTS OR TO
DE-EMPHASIZE PROPOSED IMPROVEMENTS TO
HIGHLIGHT SELECTED TRADE WORK. REFER
TO CONTEXT OF EACH SHEET FOR USAGE.
1.
2.
S O
UT
H
A
NI
LORAC
C E R T I
AU T
HO
R
C
ATE OF
I T I
A Z
O N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F I
NONE
PROJECT MANAGER
0 1" 2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET CONTRACT #: W912QG-18-F-0040
ANG PROJECT #: PSTE172020
HDR PROJECT #: 10136847
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
MCENTIRE JOINT NATIONAL GUARD BASE
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
C rv t\
\1
-0
-G
J a s o n .S e a g le .r v t
/2
/2
:2
:0
A M
G-002
NICK OVERBY
10136847-00-G.rvt
GENERAL LEGEND
S O
UT
H
A
NI
LORAC
C E R T I
AU T
HO
R
C
ATE OF
I T I
A Z
O N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F I
NONE
PROJECT MANAGER
0 1" 2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET CONTRACT #: W912QG-18-F-0040
ANG PROJECT #: PSTE172020
HDR PROJECT #: 10136847
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
MCENTIRE JOINT NATIONAL GUARD BASE
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
C rv t\
\1
-0
-F
J a s o n .S e a g le
.r v t
/2
/2
:1
:3
A M
G-003
NICK OVERBY
10136847-00-F.rvt
CODE ANALYSIS
A.SENK
A.LOCKWOOD
Z.SACHSENMAIER
SHALL BE PROVIDED.
AUTOMATIC SPRINKLER PROTECTION IS PROVIDED SMOKE BARRIERS
UNLESS AUTOMATIC SPRINKLER PROTECTION IS PROVIDED. WHERE
ROOMS AND SHOPS THAT INCLUDE WOODWORKING OR PAINTING AREA, 40.3.2.1
• SMOKE BARRIER REQUIRED FOR GENERAL STORAGE, BOILER, OR FURNACE NFPA 101 §8,7,1,2 (1), 12.3.2.1.2 (b), PROTECTION FROM HAZARDS
NOTE 1: FIRE RATING MAYBE INCREASED DUE TO OTHER CRITERIA SUCH AS FIRE AREA SEPARATION.
• ROOF CONSTRUCTION (INCLUDING SUPPORTING BEAMS AND JOISTS) 0 HOUR
• FLOOR CONSTRUCTION (INCLUDING SUPPORTING BEAMS AND JOISTS) 0 HOUR
• NONBEARING WALLS & PARTITIONS - INTERIOR 0 HOUR (NOTE 1)
• NONBEARING WALLS - EXTERIOR SEPARATION DISTANCE >30' 0 HOUR
• BEARING WALLS - INTERIOR 0 HOUR
• BEARING WALLS - EXTERIOR SEPARATION DISTANCE >30' 0 HOUR
• STRUCTURAL FRAME (INCLUDING COLUMNS, GIRDERS, AND TRUSSES) 0 HOUR
IBC 601 & TABLE 602 ALL ALLOWABLE
COMBUSTIBLE MATERIALS AS DEFINED
IN SECTION 603
IBC STRUCTURAL ELEMENTS:
FIRE RESISTANCE REQUIREMENTS
• ALLOWABLE HEIGHT: 55 FEET AND 1 STORY FOR NONSPRINKLED H-2 BUILDING IBC §504.1 TABLE 504.3/504.4
• ALLOWABLE GROSS SQUARE FEET OF BUILDING: 7,000 SQ.FT. IBC §506.2.1
ALLOWABLE IBC BUILDING HEIGHT AND FLOOR AREA:
• BUILDING IS FULLY PROTECTED WITH AN AUTOMATIC SPRINKLER SYSTEM
• BUILDING HEIGHT AND STORIES: 12FT. 0IN. AND 1 STORIES IBC § 502 BUILDING HEIGHT DEFINITION
• TOTAL BUILDING AREA: 868 SQ.FT. IBC § 502 BUILDING AREA DEFINITION
• TYPE IIB CONSTRUCTION (IBC) IBC § 602 & TABLE 601
BUILDING DESCRIPTION - PROVIDED
SPECIAL-PURPOSE HAZARD INDUSTRIAL NFPA 101 CHAPTER 40
• NFPA OCCUPANCY CLASSIFICATION NFPA 101 CHAPTER 6
HIGH-HAZARD GROUP H-2 IBC § 307 (HIGH-HAZARD)
• IBC OCCUPANCY CLASSIFICATION IBC § 302
BUILDING OCCUPANCY CLASSIFICATION
ARCHITECTURAL BARRIERS ACT (ABA), 2015 EDITION
INTERNATIONAL CODE COUNCIL, INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. (AS AMENDED BY UFC 1-200-01)
OTHER REFERENCES
NFPA 400, HAZARDOUS MATERIAL CODE, 2019
NFPA 291, RECOMMEND PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS, 2019 EDITION
NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, 2019 EDITION
NFPA 170, STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS, 2018 EDITION
NFPA 101, LIFE SAFETY CODE, 2018 EDITION.
NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATION SYSTEMS, 2019 EDITION.
NFPA 80, STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2019 EDITION
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2019 EDITION.
NFPA 70, NATIONAL ELECTRIC CODE, 2017 EDITION
NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2018 EDITION.
NFPA 1, FIRE CODE, 2018 EDITION.
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
UFC 3-601-02, OPERATION AND MAINTENANCE: INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS, 8 SEP 2010.
UFC 3-460-01, DESIGN: PETROLEUM FUEL FACILITIES, 16 AUGUST 2010, CHANGE 3, MAY 2018.
UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, 28 NOV 2016.
UFC 3-520-01, INTERIOR ELECTRICAL SYSTEMS, 26 OCTOBER 2015
UFC 1-300-02, UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS) FORMAT STANDARD CHANGE 1, 1 APRIL 2017
UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, 20 JUN 2016.
UNIFIED FACILITIES CRITERIA (UFC)
REFERENCED CODES AND STANDARDS
CODE ANALYSIS
IN DESIGN ARE LISTED):
WAY AND SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING (ONLY THOSE INCLUDED
• EACH REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE CONTINUOUS TO A PUBLIC IBC § 1009.2
ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO.
REQUIRED BY SECTION 1006.1 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH
ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS ARE
• ACCESSIBLE MEANS OF EGRESS SHALL BE PROVIDED WITH NOT LESS THAN ONE IBC § 1009.1
(NOTE: IN THE 2015 EDITION OF IBC ACCESSIBLE MEANS OF EGRESS WAS MOVED TO SECTION 1009)
ACCESSIBLE MEANS OF EGRESS. (2015 EDITION)
• ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THE IBC §1007 (2003 EDITION) ABA F207.1
THE 2015 EDITION WILL BE USED.
EGRESS AND ACCESSIBILITY. UTILIZE THE ABA. WHERE THE ABA REFERENCES THE IBC, § 2-10 & 2-11
• PER UFC 1-200-01 §2-11, DELETE CHAPTER 10 & 11 OF THE IBC FOR MEANS OF UFC 1-200-01
ACCESSIBLE MEANS OF EGRESS
• EVERY EXIT OR DIRECTIONAL SIGN SHALL BE ILLUMINATED BY A RELIABLE LIGHT SOURCE NFPA 101 § 7.10.5.1
LOCATION WHERE DIRECTION OF TRAVEL TO REACH THE NEAREST EXIT IS NOT APPARENT
• A SIGN WITH DIRECTIONAL INDICATOR SHOWING DIRECTION OF TRAVEL SHALL BE PLACED IN EVERY NFPA 101 § 7.10.2.1
THE EXIT OR WAY TO REACH EXITIS NOT READILY APPARENT TO OCCUPANTS
• ACCESS TO EXITS SHALL BE MARKED BY APPROVED, READILY VISIBLE SIGNS IN ALL CASES WHERE NFPA 101 § 7.10.1.5.1
EXITS, SHALL BE MARKED BY APPROVED SIGNS
• EXITS OTHER THAN MAIN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIED AS NFPA 101 § 7.10.1.2.1
MARKING MEANS OF EGRESS
• MINIMUM ILLUMINATION FOR FLOORS AND OTHER WALKING SURFACES SHALL BE AT LEAST 1FT. CANDLE NFPA 101 § 7.8.1.3 (2)
ILLUMINATION OF MEANS OF EGRESS
• NOT LESS THAN 36" FOR ANY MEANS OF EGRESS NFPA 101 § 7.3.4.1 (2)
MINIMUM WIDTH
SERVED.
THAN 1/3RD THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE
• MINIMUM DISTANCE SEPARATION BETWEEN EXITS AND EXIT ACCESS DOORS SHALL BE NOT LESS NFPA 101 § 7.5.1.3.3
REMOTENESS OF EXITS
• SPECIAL-PURPOSE INDUSTRIAL, (NONSPRINKLERED): 50 FEET, NFPA 101 § 40.2.5.1
DEAD-END LIMITS
• SPECIAL-PURPOSE INDUSTRIAL, (NONSPRINKLERED): 50 FEET NFPA 101 § 40.2.5.1
COMMON PATH OF TRAVEL
• SPECIAL-PURPOSE INDUSTRIAL, (NONSPRINKLERED): 300 FEET NFPA 101 § 42.2.6.1
TRAVEL DISTANCE TO AN EXIT
• OCCUPANT LOAD 1-500: NOT LESS THAN 2 MEANS OF EGRESS REQUIRED NFPA 101 § 7.4.1.1
MINIMUM NUMBER OF MEANS OF EGRESS
MEANS OF EGRESS REQUIRED; SEE LIFE SAFETY PLANS FOR EGRESS PROVIDED
INDUSTRIAL A OR B A, B, OR C A, B, OR C CLASS I OR II
GROUP EXITS
EXIT ACCESS
CORRIDORS
ROOMS AND
ENCLOSED SPACES
INTERIOR FINISH
FLOOR
INTERIOR WALL, CEILING, AND FLOOR FINISHES: NFPA 101 CHAPTER 10 TABLE A.10.2.2
UNLESS BUILDING IS PROTECTED THROUGHOUT WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM.
• FIRE DAMPERS ARE REQUIRED FOR ALL HVAC PENETRATIONS IN HORIZONTAL EXITS. NFPA 101 § 7.2.4.3.5(2)
FIRE DAMPERS REQUIRED FOR AIR TRANSFER GRILLES.
• FIRE DAMPERS NOT REQUIRED FOR FULLY DUCTED HVAC IN 1-HOUR FIRE RATED BARRIERS. NFPA 90A § 5.3.1.1
REQUIRED FIRE DAMPERS IN RATED WALLS
• FIRE EXTINGUISHERS ARE NOT REQ'D IN SPRINKLERED BUILDINGS UFC 3-300-01
ALARM
• SURGE PROTECTION DEVICE SHALL BE PROVIDED FOR ALL 120 VAC POWERED FIRE UFC 3-600-01 § 9-18.11.2
• BREAKER LOCK SHALL BE PROVIDED FOR FIRE ALARM UFC 3-520-01 UFC 3-600-01 § 9-18.11.1
• MASS NOTIFICATION SYSTEM PROVIDED WHERE OCCUPANT LOAD IS 11 OR MORE PERSONS UFC 4-010-01 § 1-6
• NOTIFICIATION TO BE PROVIDED THROUGHOUT ENTIRE BUILDING UFC 3-600-01 § 9-18.6.1
• MANUAL PULL STATION AT ALL EXIT DOORS UFC 3-600-01 § 9-18.7.4
• REMOTE ANNUNCIATOR PROVIDED AT DESIGNATED PRIMARY ENTRANCE UFC 3-600-01 § 9-18.4.4
• ANALOG / ADDRESSABLE FIRE ALARM SYSTEM SHALL BE PROVIDED UFC 3-600-01 § 9-18.4
• INDUSTRIAL OCCUPANCY - REQUIRED FOR OCCUPANT LOAD > 100 PERSONS. NFPA 101 § 40.3.4
• FIRE ALARM SYSTEM TO BE INSTALL IN ACCORDANCE WITH UFC-3-600-01, NFPA 70, NFPA 72 AND ABA
FIRE ALARM AND MASS NOTIFICATION SYSTEM (MNS)
ACTIVE FIRE PROTECTION SYSTEMS (SHALL COMPLY WITH UFC 3-600-01 CHAPTER 9)
CONSIDERATION GIVEN TO ACCESSIBILITY AND OBSTRUCTIONS.
• ALL PARTS OF THE FACILITY EXTERIOR MUST BE WITHIN 350FT OF A HYDRANT WITH UFC 3-600-01 § 9-3.5.8.2
FIRE HYDRANT PLACEMENT AND COVERAGE (UFC 3-600-01 § 9-3.5; SEE CODE COMPLIANCE SITE PLAN)
• DIMENSIONS OF FIRE LANES AND TURNAROUNDS COMPLY WITH NFPA 1.
◦ EXTERIOR DOOR ACCESSIBLE FOR FIRE DEPARTMENT INGRESS AND WITHIN 150FT OF FIRE DEPARTMENT.
• ONE MEANS OF PAVED ALL-WEATHER GROUND ACCESS NO FARTHER THAN 33 FEET FROM AN CONNECTIONS.
FIRE DEPARTMENT VEHICLE ACCESS (UFC 3-600-01 § 9-1; SEE CODE COMPLIANCE SITE PLAN)
• MECHANICAL/ELECTRICAL ROOMS: 500 SQ.FT./PERSON GROSS FLOOR AREA UFC 3-600-01, TABLE 10-1
• INDUSTRIAL USE: 100 SQ.FT./PERSON GROSS FLOOR AREA NFPA 101 TABLE 7.3.1.2
OCCUPANCY LOAD FACTORS
• LEVEL COMPONENTS (DOORS) - 0.2 INCHES PER OCCUPANT FOR DOORS IN BUILDINGS NFPA 101 TABLE 7.3.3.1
OCCUPANCY CAPACITY FACTORS
SP SP SP SP SP
P
S P
S P
SP SP SP SP
SP SP SP SP SP
PROTECTIVE
EQUIP
TOILET
DRUM
STORAGE
SERVICING
AREA
T D
-1 T
D -1
TD-1
TD-1 TD-1
T D
-4
TD-4 TD-4
TD-6
T D
-6 T
D -6
T D
-6
MECH.
TD-2
T D
-2
TD-3
T D
-3
DOOR
5' - 8"
DOOR
2' - 8"
DOOR
2' - 8"
DOOR
2' - 8"
DOOR
5' - 8"
DOOR
2' - 8"
107A 106A
105A
103A
101A
102A T
D -5
TD-5
TD-5
T D
-5
SMOKE PARTITION
CLEAR DOOR WIDTH [FEET - INCHES]
OCCUPANT LOAD CAPACITY [NO.OF PEOPLE]
EXIT DOOR TAG
LIFE SAFETY NOTES:
1. FOR EXIT LIGHTS AND EMERGENCY LIGHTING, SEE ELECTRICAL LIGHTING DRAWINGS (E SERIES).
LINE TYPES FOR MEANS OF EGRESS:
TRAVEL DISTANCE
SYMBOLCOMPONENT
LIFE SAFETY SYMBOLS:
TD
EXIT DISCHARGE ARROW
EXIT DISCHARGE
A
B
S O
UT
H
A
NI
LORAC
C E R T I
AU T
HO
R
C
ATE OF
I T I
A Z
O N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F I
PROJECT MANAGER
0 1" 2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1/4" = 1'-0"
1 2 3 4 5 6 7 8
D
C
B
A
SHEET CONTRACT #: W912QG-18-F-0040
ANG PROJECT #: PSTE172020
HDR PROJECT #: 10136847
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
MCENTIRE JOINT NATIONAL GUARD BASE
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
C rv t\
\1
-0
-F
J a s o n .S e a g le
.r v t
/2
/2
:1
:4
A M
G-004
NICK OVERBY
10136847-00-F.rvt
LIFE SAFETY PLAN
A.SENK
A.LOCKWOOD
Z.SACHSENMAIER
1/4" = 1'-0"G-004
1 LIFE SAFETY PLAN
MEANS OF EGRESS ARRANGEMENT DISTANCE
SCHEDULE - BUILDING SUMMARY
EGRESS
PATH ID
EGRESS DISTANCE
PROVIDED
MAXIMUM
PERMITTED
TD-1 23' - 6" 300' - 0"
TD-2 6' - 6" 300' - 0"
TD-3 6' - 0" 300' - 0"
TD-4 14' - 6" 300' - 0"
TD-5 26' - 0" 300' - 0"
TD-6 15' - 6" 300' - 0"
WALL RATINGS
MEANS OF EGRESS WIDTH CAPACITY - LEVEL 1
EXIT ID
PROVIDED EGRESS CAPACITY - LEVEL
COMPONENTS & RAMPS
EGRESS
CAPACITY
FACTOR
CLEAR
WIDTH
OCCUPANT LOAD
CAPACITY
101A 0.2 5' - 8" 340
102A 0.2 5' - 8" 340
103A 0.2 2' - 8" 160
105A 0.2 2' - 8" 160
106A 0.2 2' - 8" 160
107A 0.2 2' - 8" 160
JUNE 2019 B-2 DESIGN SUBMISSION
INDUSTRIAL 800 100 8
OCCUPANT USE
TYPE
AREA
(SQ FT)
OCCUPANT
LOAD FACTOR
(SF/PERSON) OCCUPANT LOAD
OCCUPANT LOAD SCHEDULE
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
PROJECT MANAGER
HDR PROJECT #:
0 1" 2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
ALLAN GOFF
ALLAN GOFF
ROBERT BAYSDEN
10136847
NICK OVERBY
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
ANG PROJECT #:
PSTE172020
CONTRACT #:
W912QG-18-F-0040
MCENTIRE JOINT NATIONAL GUARD BASE
S
O
U
T
H
A
N
I
L
O
R A
C
C
E
R
T
I
A
U
T
H
O
R
C
A
T
E
O
F
I
T
I
A
Z
O
N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F
I
G-005
G-005.DWG
CODE COMPLIANCE
SITE PLAN
1" = 20'
ADAM SENK
ADELAINE LOCKWOOD
ZACH SACHSENMAIER
- JUNE 2019 B-2 DESIGN SUBMISSION
LEGEND:
KEY NOTES:
1. ALL PARTS OF BUILDING EXTERIOR WITHIN 350
FT AS REQUIRED UFC 3-600-01 PARA. 9-3.5.8.2.
2. ALL WEATHER GROUND ACCESS SHALL BE
PROVIDED FOR EMERGENCY VEHICLES PER UFC
3-600-01 PARA 9-1.1.
3. FIRE DEPARTMENT CONNECTION PROVIDED
WITHIN 150 FT AS REQUIRED BY UFC 3-600-01
PARA. 3-7.3.3.
4. FIRE ALARM/SPRINKLER RISER ROOM.
5. FIRE HOSE PULL 150 FT.
6. FIRE WATER SUPPLY ISOLATION GATE VALVE
BELOW GRADE IN VALVE BOX
7. SITE FENCE
8. FIRE WATER SUPPLY
F-101
CODE COMPLIANCE SITE PLAN
SCALE: 1" = 20' - 0"
HOSE PULL
HYDRANT
C p w w o r k i n g e a s t d
G d w g
P l o t
A
M
A
L O
C K
W O
O D
AutoCAD SHX Text
FH
AutoCAD SHX Text
FH
AutoCAD SHX Text
PAVEMENT
AutoCAD SHX Text
6' WOVEN WIRE FENCE WITH BARB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
DRIVEWAY
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text
FH
AutoCAD SHX Text
FH
AutoCAD SHX Text
PAVEMENT
AutoCAD SHX Text
6' WOVEN WIRE FENCE WITH BARB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
DRIVEWAY
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text
ASPHALT
ALOCKWOOD
Text Box
A.SENK
ALOCKWOOD
Text Box
A.LOCKWOOD
ALOCKWOOD
Text Box
Z. SACHSENMAIER
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
PROJECT MANAGER
HDR PROJECT #:
0 1"
2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
ALLAN GOFF
ALLAN GOFF
ROBERT BAYSDEN
10136847
NICK OVERBY
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
ANG PROJECT #: PSTE172020
CONTRACT #: W912QG-18-F-0040
MCENTIRE JOINT NATIONAL GUARD BASE
S
O
U
T
H
A
N
I
L
O
R A
C
C
E
R
T
I
A
U
T
H
O
R
C
A
T
E
O
F
I
T
I
A
Z
O
N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F
I
C-000
C-000.DWG
CIVIL LEGEND
- JUNE 2019 B-2 DESIGN SUBMISSION
UTILITY BENEATH STRUCTURE
LARGE PIPELINE
PIPELINE
CENTERLINE
PROPERTY LINE
EASEMENT
LIMITS OF DISTURBANCE
ROW
LOD LOD LOD LOD
EXISTING CONTOUR W/ ELEVATION (MAJOR)
EXISTING CONTOUR (MINOR)
CONTOUR W/ ELEVATION (MAJOR)
HIGHWAY GUARDRAIL
EXISTING VEGETATION/BRUSH LINE
X X X X X X
SECURITY FENCE
SILT FENCE
DOWNGUY
SURVEY BENCHMARK
SPOT ELEVATION
SURVEY CONTROL POINT
IDENTIFICATION AND APPROXIMATE
LOCATION OF SOIL TEST HOLE
CIVIL MAPPING SYMBOLOGY
BUOY
STORM OPEN THROAT CATCH BASIN
STORM SPLITTER BOX
EMBANKMENT SLOPE (CUT)
FLOW ARROW
EMBANKMENT SLOPE RIGHT ARROW RIGHT
EMBANKMENT SLOPE LEFT ARROW LEFT
CLEANOUT
FUEL OIL METER
FUEL OIL MANHOLE
FUEL OIL VAULT
EMBANKMENT SLOPE (FILL)
GREASE TRAP
GRIT CHAMBER
NATURAL GAS METER
NATURAL GAS RECEIVER
NATURAL GAS TRAP
NATURAL GAS LINE VAULT
HEADWALL
HORIZONTAL CONTROL POINT
VERTICAL CONTROL POINT
INTERSTATE HIGHWAY SYMBOL
INDUSTRIAL WASTE WATER METER
INDUSTRIAL WASTE WATER MANHOLE
EXTERIOR UTILITY JUNCTION BOX
MONITORING WELL
POST INDICATOR VALVE
PUMP STATION
RAIL SIGNAL
RAIL SWITCH
SECTION CORNER MONUMENT
SECTION CORNER NO MONUMENT
STORM DRAINAGE MANHOLE
SIGN
SANITARY MANHOLE
SEPTIC TANK
STATE HIGHWAY SYMBOL
TIDE GAUGE
TIRE TREDDLE
TRAFFIC ARM WITH CARD READER
TRAFFIC ARM MECHANICAL SWING
US HIGHWAY SYMBOL
WATER/AIR VENT
WATER BACKFLOW PREVENTER
WATER LEVEL IN SECTION/PROFILE
EXISTING UTILITY POLE
UTILITY/CIVIL LINE SYMBOLOGY
GATE VALVE
FIRE HYDRANT
CULVERT END SYMBOL
(WITH CULVERT SHOWN BETWEEN SYMBOLS)
H:V
H:V
CP-X
MW
CO
D
S
XXX
XXX
XXX
R R
F
F
F
GT
GC
G
G
G
G
I
I
J
X
PS
X
ST
W
W
X
X
In
WATER BLOWOFF
WATER METER
WATER SHUTOFF
WATER SOFTENER
WATER VALVE VAULT
WS
PIEZOMETER
TANK BELOW GROUND
TANK HORIZONTAL ABOVE GROUND
TANK VERTICAL ABOVE GROUND
X
X
X
TEMPORARY SEDIMENT TRAP
HAY BALE
SOIL BORING
X
TEST PIT
FLOOD LIMIT (100 YEAR)
X
X
X
A. THIS IS A STANDARD CIVIL SYMBOLOGY SHEET. ALL SYMBOLS ARE NOT
NECESSARILY USED ON THIS PROJECT.
B. SCREENING OR SHADING OF WORK IS USED TO INDICATE EXISTING
COMPONENTS OR TO DE-EMPHASIZE PROPOSED IMPROVEMENTS TO
HIGHLIGHT SELECTED TRADE WORK. REFER TO CONTEXT OF EACH
SHEET FOR USAGE.
TREE PROTECTION FENCE
STORM FLARED END SECTION
DIVERSION SWALE
TREE LINE
WETLAND BUFFER
LINEAR REMOVAL/DEMOLITION
HEAVY DUTY ASPHALT PAVEMENT
CONCRETE SIDEWALK
SEDIMENT TUBE
YARD INLET SEDIMENT FILTER
W W
EXISTING ELECTRICAL
EXISTING WATER
EXISTING SANITARY SEWER
EXISTING TREE LINE
CONTOUR (MINOR)
X X X X X X
EXISTING SECURITY FENCE
RIPRAP
SILT FENCE ROCK OUTLET
STORM DRAINAGE DROP INLET
EXISTING OVERHEAD ELECTRICAL
EXISTING UNDERGROUND FIBER OPTIC
EXISTING UNDERGROUND TELEPHONE
OHE
PLUG VALVE
LIGHT DUTY ASPHALT PAVEMENT
ASPHALT PAVEMENT DEMOLITION
CONCRETE PAVEMENT DEMOLITION
MACHINE CLEAR AND GRUB
CONCRETE WHEEL STOP
SB
OT
EXISTING UNDERGROUND ELECTRICAL
EXISTING UNDERGROUND GAS
WETLANDS
WW
WATER MAIN
SEWER FORCE MAIN
STORM DRAINAGE PIPING
FM FM FM FM FM
GRAVITY SEWER PIPING
BLOCK & GRAVEL CURB
INLET SEDIMENT FILTER
CONSTRUCTION ENTRANCE
HEAVY DUTY CONCRETE PAVEMENT
1 STAKING POINT
FFE = 123
BUILDING FINISHED FLOOR ELEVATION
GAS PIPING
RIPRAP OUTLET PROTECTION
GENERAL SHEET NOTES
±800-SF
HYDRAZINE
FACILITY
26.67'
LIMITS OF DISTURBANCE
(0.55-ACRES)
MILL 2-INCHES
EXISTING ASPHALT
AND RESURFACE
(±650-SY)
±935-SF HEAVY DUTY
CONCRETE PAVEMENT
±250-LF 7-FT CHAINLINK
FENCE WITH BARB WIRE
3-FT WALK THROUGH GATE
16-FT ROLLING GATE
±25-SF
CONCRETE SIDEWALK
±50-SF
CONCRETE SIDEWALK
SAWCUT EDGE
25.24'
SS
S S
S S
W
W
W
W
W
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
PROJECT MANAGER
HDR PROJECT #:
0 1"
2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
ALLAN GOFF
ALLAN GOFF
ROBERT BAYSDEN
10136847
NICK OVERBY
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
ANG PROJECT #: PSTE172020
CONTRACT #: W912QG-18-F-0040
MCENTIRE JOINT NATIONAL GUARD BASE
S
O
U
T
H
A
N
I
L
O
R A
C
C
E
R
T
I
A
U
T
H
O
R
C
A
T
E
O
F
I
T
I
A
Z
O
N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F
I
C-001
C-001.DWG
OVERALL SITE
PLAN
1" = 20'
- JUNE 2019 B-2 DESIGN SUBMISSION
SD
SD
SD
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S D
S D
S D
S D
S D
S D
S D
SD
SD
SD
S D
LIMITS OF DISTURBANCE
(0.55-ACRES)
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
PROJECT MANAGER
HDR PROJECT #:
0 1"
2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
ALLAN GOFF
ALLAN GOFF
ROBERT BAYSDEN
10136847
NICK OVERBY
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
ANG PROJECT #: PSTE172020
CONTRACT #: W912QG-18-F-0040
MCENTIRE JOINT NATIONAL GUARD BASE
S
O
U
T
H
A
N
I
L
O
R A
C
C
E
R
T
I
A
U
T
H
O
R
C
A
T
E
O
F
I
T
I
A
Z
O
N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F
I
C-002
C-002.DWG
SITE
DEMOLITION PLAN
1" = 20'
- JUNE 2019 B-2 DESIGN SUBMISSION
REMOVE METAL BUILDING
AND STAIRS
ABANDON EXISTING VALVE IN PLACE
SD
SD
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S D
S D
S D
S D
S D
S D
S D
SD
SD
SD
S D
S F
S F
S F
SF
SF SF
SF SF
S F
S F
S F
S F
S F
S F
S F
S F
S F
S F
SF SF
SF
SF SF
SF SF
SF SF
SF
SF SF
SF SF
SF
SF SF
SF SF
SF
SF SF
SF SF
SF
SF SF
SF SF
SF SF
SF
SF SF
SF SF
SF
SF SF
SF SF
SF
SF SF
SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SF
SF
SF SF
SF
S F
S F
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
S F
S F
S F
S F
S F
S F
S F
S F
S F
S F
S F
TEMPORARYSILT FENCE
00C-07
CONCRETE WASHOUT AREA
00C-07
SILT FENCE ROCK OUTLET (TYP.)
00C-06
(2) TYPE A INLET
PROTECTION
00C-07
(2) TYPE A INLET PROTECTION
00C-07
TYPE A INLET PROTECTION
00C-07
TYPE A INLET
PROTECTION
00C-07
LIMITS OF DISTURBANCE
(0.55-ACRES)
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
PROJECT MANAGER
HDR PROJECT #:
0 1"
2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
ALLAN GOFF
ALLAN GOFF
ROBERT BAYSDEN
10136847
NICK OVERBY
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
ANG PROJECT #: PSTE172020
CONTRACT #: W912QG-18-F-0040
MCENTIRE JOINT NATIONAL GUARD BASE
S
O
U
T
H
A
N
I
L
O
R A
C
C
E
R
T
I
A
U
T
H
O
R
C
A
T
E
O
F
I
T
I
A
Z
O
N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F
I
C-003
C-003.DWG
CIVIL EROSION
CONTROL PLAN
SD
SD
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S D
S D
S D
S D
S D
S D
S D
SD
SD
SD
S D
LIMITS OF DISTURBANCE
(0.55-ACRES)
SS
S S
S S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
EL 231.90
EL 231.18
EL 231.17
EL 231.22
EL 231.40
EL 231.40
±800-SF
HYDRAZINE
FACILITY
(FFE = 231.90)
EL 231.40
EL 231.40
EL 231.40
EL 231.40
EL 231.15
EL 231.90
EL 231.90
EL 231.40
EL 231.90
EL 231.90
EL 231.90
EL 231.90
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
PROJECT MANAGER
HDR PROJECT #:
0 1"
2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
ALLAN GOFF
ALLAN GOFF
ROBERT BAYSDEN
10136847
NICK OVERBY
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
ANG PROJECT #: PSTE172020
CONTRACT #: W912QG-18-F-0040
MCENTIRE JOINT NATIONAL GUARD BASE
S
O
U
T
H
A
N
I
L
O
R A
C
C
E
R
T
I
A
U
T
H
O
R
C
A
T
E
O
F
I
T
I
A
Z
O
N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F
I
C-004
C-004.DWG
CIVIL GRADING
AND DRAINAGE PLAN
SD
SD
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S D
S D
S D
S D
S D
S D
S D
SD
SD
SD
S D
LIMITS OF DISTURBANCE
(0.55-ACRES)
SS
S S
S S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
±311-LF 2-INCH HDPE FORCEMAIN
(2) 2-INCH 45° HDPE BENDS
11,000 GALLON H-70 NEUTRALIZATION
TANK WITH DE-WATERING PUMP SYSTEM
EXISTING FIRE HYDRANT
TO BE MAINTAINED
±60-LF OF 2-INCH HDPE
DOMESTIC WATER SERVICE LINE
2-INCH FORCE MAIN
CONNECTION TO
EXISTING MANHOLE
(APPROX. LOCATION)
±18-LF 4-INCH HDPE DRAIN LINE
(2) 4-INCH HDPE 45° BENDS
PACKAGE GRINDER PUMP STATION
8x2-INCH TAPPING SADDLE
±39-LF 4-INCH SSWR GRAVITY SERVICE LINE
(2) 4-INCH HDPE 45° BEND
4-INCH SEWER CLEANOUT
EXISTING 8-INCH WATERLINE
TO BE MAINTAINED
±17-LF 4-INCH HDPE DRAIN LINE
(2) 4-INCH HDPE 45° BENDS
4" SEWER CLEANOUT
ON DRAIN LINE
PRELIMINARY
NOT FOR
CONSTRUCTION
OR
RECORDING
PROJECT MANAGER
HDR PROJECT #:
0 1"
2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
ALLAN GOFF
ALLAN GOFF
ROBERT BAYSDEN
10136847
NICK OVERBY
HYDRAZINE FACILITY
SC AIR NATIONAL GUARD
169TH FIGHTER WING
EASTOVER, SC
ANG PROJECT #: PSTE172020
CONTRACT #: W912QG-18-F-0040
MCENTIRE JOINT NATIONAL GUARD BASE
S
O
U
T
H
A
N
I
L
O
R A
C
C
E
R
T
I
A
U
T
H
O
R
C
A
T
E
O
F
I
T
I
A
Z
O
N
HDR ENGINEERING,
INC.
OF THE CAROLINAS
NO. C0318
F
I
C-005
C-005.DWG
CIVIL
UTILITY PLAN
6. LIME AND FERTILIZER SHALL BE APPLIED UNIFORMLY AND MIXED WITH THE SOIL DURING SEEDBED
PREPARATION. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DEPENDING ON
FIELD CONDITION.
7. MULCH TO BE TACKED OR MECHANICALLY TIED DOWN IMMEDIATELY AFTER MULCH IS SPREAD.
8. ALL SLOPES GREATER THAN 3:1 SHALL BE STABILIZED WITH NORTH AMERICAN GREEN SC150 OR
EQUIVALENT
STABILIZATION REQUIREMENTS
TEMPORARY OR PERMANENT GROUND COVER STABILIZATION SHALL OCCUR WITHIN 7 CALENDAR DAYS
FROM THE LAST LAND-DISTURBING ACTIVITY, WITH THE FOLLOWING EXCEPTIONS IN WHICH
TEMPORARY OR PERMANENT GROUND COVER SHALL BE PROVIDED IN 14 CALENDAR DAYS FROM THE
LAST LAND-DISTURBING ACTIVITY:
· SLOPES BETWEEN 2:1 AND 3:1, WITH A SLOPE LENGTH OF 10 FT. OR LESS
· SLOPES 3:1 OR FLATTER, WITH A SLOPE OF LENGTH OF 50 FT. OR LESS
· SLOPES 4:1 OR FLATTER
NATIVE GRASS SEEDING AND MULCHING: (EAST)
NATIVE GRASS SEEDING AND MULCHING SHALL BE PERFORMED ON THE DISTURBED AREAS OF
WETLANDS AND RIPARIAN AREAS, AND ADJACENT TO STREAM RELOCATION CONSTRUCTION WITHIN A
50 FOOT ZONE ON BOTH SIDES OF THE STREAM OR DEPRESSION, MEASURED FROM TOP OF STREAM
BANK OR CENTER OF DEPRESSION. THE STREAM BANK OF THE STREAM RELOCATION SHALL BE
SEEDED BY A METHOD THAT DOES NOT ALTER THE TYPICAL CROSS SECTION OF THE STREAM BANK.
NATIVE GRASS SEEDING AND MULCHING SHALL ALSO BE PERFORMED IN THE PERMANENT SOIL
REINFORCEMENT MAT SECTION OF PREFORMED SCOUR HOLES, AND IN OTHER AREAS AS DIRECTED.
THE KINDS OF SEED AND FERTILIZER, AND THE RATES OF APPLICATION OF SEED, FERTILIZER, AND
LIMESTONE, SHALL BE AS STATED BELOW. DURING PERIODS OF OVERLAPPING DATES, THE KIND OF
SEED TO BE USED SHALL BE DETERMINED. ALL RATES ARE IN POUNDS PER ACRE.
FERTILIZER SHALL BE 10-20-20 ANALYSIS. A DIFFERENT ANALYSIS OF FERTILIZER MAY BE USED
PROVIDED THE 1-2-2 RATIO IS MAINTAINED AND THE RATE OF APPLICATION ADJUSTED TO PROVIDE
THE SAME AMOUNT OF PLANT FOOD AS A 10-20-20 ANALYSIS AND AS DIRECTED.
NATIVE GRASS SEEDING AND MULCHING SHALL BE PERFORMED IN ACCORDANCE WITH SECTION 1660
OF THE STANDARD SPECIFICATIONS AND VEGETATIVE COVER SUFFICIENT TO RESTRAIN EROSION
SHALL BE INSTALLED IMMEDIATELY FOLLOWING GRADE ESTABLISHMENT.
TEMPORARY SEEDING
FERTILIZER SHALL BE THE SAME ANALYSIS AS SPECIFIED FOR SEEDING AND MULCHING AND APPLIED
AT THE RATE OF 400 POUNDS AND SEEDED AT THE RATE OF 50 POUNDS PER ACRE. GERMAN MILLET
OR BROWNTOP MILLET SHALL BE USED IN SUMMER MONTHS AND RYE GRAIN DURING THE REMAINDER
OF THE YEAR. THE ENGINEER WILL DETERMINE THE EXACT DATES FOR USING EACH KIND OF SEED.
FERTILIZER TOPDRESSING
FERTILIZER USED FOR TOPDRESSING SHALL BE 16-8-8 GRADE AND SHALL BE APPLIED AT THE RATE OF
500 POUNDS PER ACRE. A DIFFERENT ANALYSIS OF FERTILIZER MAY BE USED PROVIDED THE 2-1-1
RATIO IS MAINTAINED AND THE RATE OF APPLICATION ADJUSTED TO PROVIDE THE SAME AMOUNT OF
PLANT FOOD AS 16-8-8 ANALYSIS AND AS DIRECTED.
SUPPLEMENTAL SEEDING
THE KINDS OF SEED AND PROPORTIONS SHALL BE THE SAME AS SPECIFIED FOR SEEDING AND
MULCHING, AND THE RATE OF APPLICATION MAY VARY FROM 25# TO 75# PER ACRE. THE ACTUAL RATE
PER ACRE WILL BE DETERMINED PRIOR TO THE TIME OF TOPDRESSING AND THE CONTRACTOR WILL
BE NOTIFIED IN WRITING OF THE RATE PER ACRE, TOTAL QUANTITY NEEDED, AND AREAS ON WHICH
TO APPLY THE SUPPLEMENTAL SEED. MINIMUM TILLAGE EQUIPMENT, CONSISTING OF A SOD SEEDER
SHALL BE USED FOR INCORPORATING SEED INTO THE SOIL AS TO PREVENT DISTURBANCE OF
EXISTING VEGETATION. A CLODBUSTER (BALL AND CHAIN) MAY BE USED WHERE DEGREE OF SLOPE
PREVENTS THE USE OF A SOD SEEDER.
MOWING
THE MINIMUM MOWING HEIGHT SHALL BE 4 INCHES.
CLEARING:
CLEARING SHALL INCLUDE THE TRIMMING OF ONLY THOSE TREES OVERHANGING THE CLEARING LIMITS
AS NECESSARY TO PERFORM THE WORK. THE CONTRACTOR SHALL ALSO CLEAR THOSE AREAS OR
FEATURES SPECIFICALLY SHOWN ON THE PLANS TO BE CLEARED. CLEARING SHALL NOT INCLUDE THE
UNNECESSARY REMOVAL OF TREES, GRASS, TURF, BRUSH, OR LANDSCAPING OR SIMILAR GROUND
COVERS OR OTHER VEGETATION. THE CONTRACTOR SHALL NOT CONDUCT ANY CLEARING
OPERATIONS OUTSIDE THE LIMITS SPECIFIED, UNLESS APPROVED BY THE OWNER/ENGINEER. ALL
OTHER SUCH FEATURES REMOVED OR DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES BY THE
CONTRACTOR SHALL BE RESTORED TO ORIGINAL CONDITION.
TEMPORARY AND PERMANENT NON LAWN SEEDING MEASURES
A. GENERAL:
1. AFTER CONSTRUCTION IS COMPLETE IN ANY AREA OR PHASE OF THE PROJECT, THE DISTURBED
AREAS SHALL RECEIVE A PERMANENT GROUND COVER. SEEDING AND MULCHING SHALL BE
PERFORMED IMMEDIATELY BEHIND CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE
PERMANENT SEEDING IN ALL DISTURBED AREAS AS INDICATED IN THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL ADAPT PERMANENT SEEDING OPERATIONS TO PROTECT AND TO
ACCOMMODATE ANY TEMPORARY SEEDING AND SOIL AND EROSION CONTROL MEASURES THAT
MAY ALREADY BE IN PLACE DURING THE WORK PERIOD.
2. WHEN SEEDING MUST TAKE PLACE OUT OF SEASON FOR PERMANENT GRASS THE APPROPRIATE
TEMPORARY SEEDING SHALL BE DONE AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PERMANENT SEEDING AS SPECIFIED IN SEASON AT NO ADDITIONAL COST TO OWNER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR TURF MAINTENANCE THROUGH SUBSTANTIAL
COMPLETION. SLOPES MUST BE AT 90% COVERAGE AT SUBSTANTIAL COMPLETION REVIEW TO BE
ACCEPTED. IF NOT AT 90% COVERAGE, SUBSTANTIAL COMPLETION WILL BE DELAYED UNTIL THE
FOLLOWING GROWING SEASON.
B. SITE PREPARATION AND INSTALLATION:
1. GROUND COVER: ALL DISTURBED AREAS SHALL BE DRESSED TO A DEPTH OF FIVE (5) INCHES. THE
TOP TWO (2) INCHES SHALL BE PULVERIZED TO PROVIDE A UNIFORM SEEDBED. RAKE OR HARROW
THE SITE TO ESTABLISH A SMOOTH AND LEVEL FINAL GRADE. SOIL PARTICLES SHOULD BE NO
LARGER THAN MARBLE SIZE, AND PEA GRAVEL SIZE IS EVEN BETTER. AGRICULTURAL LIME SHALL
BE APPLIED AT THE RATE OF 95 LBS./1000 SQ. FT. IMMEDIATELY BEFORE PLOWING. GRASS SEED
SHALL BE APPLIED AT THE RATES OUTLINED IN TABLES 2A AND 2B.
2. 5-10-10 FERTILIZER SHALL BE APPLIED TO ALL DISTURBED AREAS AT A RATE OF 21 LBS./1000 SQ. FT.
MULCHING SHALL CONSIST OF SMALL GRAIN STRAW APPLIED AT A RATE OF 2 TONS/ACRE.
MULCHED AREAS SHALL BE TACKED WITH ASPHALT OR OTHER APPROVED METHOD SUFFICIENT TO
HOLD THE STRAW IN PLACE, AT A RATE OF 150 TO 200 GALLONS PER TON OF STRAW.
3. IF ACTIVE CONSTRUCTION CEASES IN ANY AREA FOR MORE THAN FOURTEEN (14) DAYS, ALL
DISTURBED AREAS MUST BE SEEDED, MULCHED, FERTILIZED AND TACKED AT NO ADDITIONAL COST
TO THE OWNER.
4. SOME AREAS MAY REQUIRE TEMPORARY SEEDING DUE TO AN INTERRUPTION OF WORK
EXCEEDING FOURTEEN (14) DAYS OR SEASONAL RESTRICTIONS AS SPECIFIED IN THE PERMANENT
SEEDING SCHEDULE, OR A COMBINATION THEREOF. THESE AREAS SHALL BE RESEEDED IN
ACCORDANCE WITH THE PERMANENT SEEDING SCHEDULE. IF TEMPORARY SEEDING IS REQUIRED
DUE TO CONTRACTOR DELAYS, THERE WILL BE NO COMPENSATION FOR THE TEMPORARY
SEEDING. TEMPORARY SEEDING SHALL BE PERFORMED ONLY AT THE DIRECTION OF THE
ENGINEER OR INSPECTOR.
C. CLEANUP AND INSPECTION:
1. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL REMOVE FROM THE SITE ALL EQUIPMENT
AND OTHER ARTICLES USED. ALL EXCESS SOIL, STONE, AND DEBRIS SHALL BE REMOVED AND
LEGALLY DISPOSED OF AT NO ADDITIONAL COST TO THE OWNER. ALL WORK AREAS SHALL BE LEFT
IN A CLEAN AND NEAT CONDITION. ALL DAMAGE TO EXISTING CONSTRUCTION CAUSED BY
LANDSCAPING OPERATIONS SHALL BE REPAIRED TO THE SATISFACTION OF THE TOWN AT THE
CONTRACTOR'S EXPENSE.
2. SEEDED AREAS SHALL BE PROTECTED AND REPLANTED AS NECESSARY TO ESTABLISH A UNIFORM
STAND OF SPECIFIED GRASS. SCATTERED BARE SPOTS, NONE OF WHICH SHALL BE LARGER THAT
ONE (1) SQUARE FOOT, WILL BE ALLOWED UP TO A MAXIMUM OF 3% OF THE SEEDED AREA FOR
EACH PROPERTY. WHEN SEEDED AREAS ARE READY FOR INSPECTION, THE MAINTAINED TURF
AREAS SHALL BE NEATLY MOWED TO THE UNIFORM HEIGHT OF APPROXIMATELY TWO AND
ONE-HALF (2.5) INCHES. THE LAWNS SHALL BE CONSIDERED ESTABLISHED ONLY WHEN THE
SPECIFIED GRASS IS VIGOROUS AND GROWING WELL IN ADDITION TO MEETING THE OTHER
REQUIREMENTS SPECIFIED.
3. AN INSPECTION OF THE COMPLETED SEEDING SHALL BE MADE AT THE CONCLUSION OF THE
LANDSCAPE WORK UPON WRITTEN NOTICE REQUESTING SUCH INSPECTION SUBMITTED BY THE
CONTRACTOR TO THE ENGINEER, AT LEAST TEN (10) DAYS PRIOR TO THE ANTICIPATED DATE OF
INSPECTION.
4. A FINAL INSPECTION SHALL BE PERFORMED WHEN A SATISFACTORY STAND OF SEEDED TURF
GRASS HAS BEEN PRODUCED, UPON WRITTEN NOTICE REQUESTING SUCH INSPECTION SUBMITTED
BY THE CONTRACTOR TO THE ENGINEER, AT LEAST TEN (10) DAYS PRIOR TO THE ANTICIPATED
DATE OF INSPECTION. IF A SATISFACTORY STAND OF TURF HAS NOT BEEN PRODUCED AT THE
TIME OF FINAL INSPECTION, NECESSARY REPAIRS SHALL BE PERFORMED IN CONFORMANCE WITH
THE REQUIREMENTS OF THIS SECTION. UPON COMPLETION OF THESE REPAIRS, THE SEEDED
GRASS SHALL BE REINSPECTED UPON WRITTEN NOTICE AS ABOVE.
SEEDBED PREPARATION NOTES
1. SURFACE WATER CONTROL MEASURES TO BE INSTALLED ACCORDING TO PLAN.
2. AREAS TO BE SEEDED SHALL BE RIPPED AND SPREAD WITH AVAILABLE TOPSOIL 3 INCH DEEP.
TOTAL SEEDBED PREPARED DEPTH SHALL BE 4 INCH TO 6 INCH DEEP.
3. LOOSE ROCKS, ROOTS AND OTHER OBSTRUCTIONS SHALL BE REMOVED FROM THE SURFACE SO
THAT THEY WILL NOT INTERFERE WITH ESTABLISHMENT AND MAINTENANCE OF VEGETATION.
SURFACE FOR FINAL SEEDBED PREPARATION AT FINISHED GRADES SHOWN SHALL BE
REASONABLY SMOOTH AND UNIFORM.
4. IF NO SOIL TEST IS TAKEN, FERTILIZER AND LIME TO BE ACCORDING TO SEEDING SPECIFICATIONS
BELOW. IN ADDITION, PROVIDE 15 LBS/1000 SF OF SUPERPHOSPHATE.
5. IF SOIL TEST IS TAKEN, PROVIDE LIME AND FERTILIZER ACCORDING TO SOIL TEST REPORT.
PERMANENT LAWN SEEDING MEASURES
A. GENERAL
1. THE FOLLOWING INFORMATION SHALL BE APPLICABLE FOR ALL PERMANENT LAWN SEEDING.
PERMANENT LAWN SEEDING SHALL TAKE PLACE WITHIN ALL DEVELOPED AREAS OF DISTURBANCE
INCLUDING RESIDENTIAL AND COMMERCIAL AREAS AND SHALL BE REPLACED IN KIND OF EXISTING
MATERIAL BY THE CONTRACTOR. AN APPROVED TURF TYPE TALL FESCUE BLEND SHALL BE USED
PER THE CONTRACT DOCUMENTS. KENTUCKY 31 IS NOT AN ACCEPTABLE BLEND.
2. WHEN SEEDING MUST TAKE PLACE OUT OF SEASON FOR PERMANENT GRASS THE APPROPRIATE
TEMPORARY SEEDING SHALL BE DONE AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PERMANENT SEEDING AS SPECIFIED IN SEASON AT NO ADDITIONAL COST TO OWNER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR LAWN MAINTENANCE THROUGH SUBSTANTIAL
COMPLETION. LAWNS MUST BE AT 90% COVERAGE AT SUBSTANTIAL COMPLETION REVIEW TO BE
ACCEPTED. IF NOT AT 90% COVERAGE, SUBSTANTIAL COMPLETION WILL BE DELAYED UNTIL THE
FOLLOWING GROWING SEASON.
B. SITE PREPARATION:
1. REMOVE OR KILL ANY UNDESIRABLE EXISTING TURF OR VEGETATION. HERBICIDE SPRAYING OR
OTHER CHEMICAL TREATMENT SHALL BE APPROVED BY THE ENGINEER PRIOR TO BEING USED BY
THE CONTRACTOR. IF PREEXISTING TURF OR OTHER VEGETATION IS MIXED WITH THE SOIL TO BE
REUSED, THE CONTRACTOR SHALL USE BEST JUDGEMENT IN REMOVING IT OR INCORPORATING IT
INTO THE SOIL DURING PREPARATION.
2. IF TOPSOIL WAS NOT USED TO REESTABLISH THE UPPER SOIL LAYER AND THE UPPER SOIL IS
HEAVY WITH HIGH CLAY CONTENT, SPREAD 1.5-2 INCHES OF AGED GROUND PINE BARK OR BAGGED
ORGANIC HUMUS OVER THE AREA TO BE REPAIRED.
3. FOR ALL GRASSES EXCEPT CENTIPEDE GRASS, APPLY PER 1,000 SQUARE FEET: 75 POUNDS OF
GROUND LIMESTONE AND ONE OF THE FOLLOWING FERTILIZERS: 40 POUNDS OF 5-10-10; 20
P…