Attach_4._List_of_Heatpump_Equip.pdf
PDF 233 KB Posted
- Solicitation number
- W91QVN20R0202
About this file
This document contains an attachment listing heating system equipment and a federal contract opportunity solicitation for preventive maintenance and repair services of that heating system. The solicitation was issued by the Department of the Army Materiel Command Army Contracting Command for preventive maintenance and repair/replacement services of heating equipment listed in an attached equipment list. The list details various heat pumps, circulation pumps, chillers, air handling units, cooling towers, and other heating system components by manufacturer, model, quantity, specifications, and location. The solicitation requests pricing proposals for repair/replacement parts and installation/removal labor to be submitted through the beta.SAM website by the response date.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment W91QVN20R0202-0001.pdf | ||
| Attach_6._Repair_Replacement Parts List_KRW.xlsx | XLSX spreadsheet | |
| RFP W91QVN20R0202_Preventive Maintenance_Repair Services of Heating System.pdf | ||
| Attach_3._List-of-Heating-Equipment.xlsx | XLSX spreadsheet | |
| Attach_7._On call service list for Heating.xlsx | XLSX spreadsheet | |
| Attach_10._PM_Tasks_Cycles.pdf | ||
| Attach_8._On call service list for Heat Pump.xlsx | XLSX spreadsheet | |
| Attach_6._Repair_Replacement Parts List.xlsx | XLSX spreadsheet | |
| Attach_5._Minor_Parts_less_than_$250.pdf | ||
| Attach_1._Heating_System_&_Service_Area(SF).pdf | ||
| Attach_2._Heat_Pump_Systems_and_Service_Areas_(SF).pdf | ||
| Attach_9._Inspection_Checklist_for_AST_Dike.pdf | ||
| Attach 11._Installation_ Removal ELINs Price List.xlsx | XLSX spreadsheet |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 4
List of Heat Pump Equipment
Capacity Power Consumption
GEVB060 TRANE 30 Heating :73.8 MBTUH Cooling
:57.9 MBTUH
4.84KW Located on 30 units
GEVB042 TRANE 5 Heating :48.5 MBTUH Cooling
:39.5 MBTUH
3.46KW Located on 1st ~5th Floor Hall
M2515T BALDOR 2 20 HP for condensing water M3218T BALDOR 2 5 HP for cooling tower
Coolingtower VTL092‐L BALTIMORE 1 92 ton Roof Floor GKX26 Jang‐Han Tech. 1 193,900 kcal/h Mech. Room HT 153H‐1P‐137 DHT co., LTD 1 Roof Floor
GEVB060 TRANE 30 Heating :73.8 MBTUH Cooling
:57.9 MBTUH
4.84KW Located on 30 units
GEVB042 TRANE 5 Heating :48.5 MBTUH Cooling
:39.5 MBTUH
3.46KW Located on 1st ~5th Floor Hall
M2515T BALDOR 2 20 HP for condensing water M3218T BALDOR 2 5 HP for cooling tower
Coolingtower VTL092‐L BALTIMORE 1 92 ton Roof Floor GKX26 Jang‐Han Tech. 1 193,900 kcal/h Mech. Room HT 153H‐1P‐137 DHT co., LTD 1 Roof Floor
GEHB060 TRANE 8 Heating :73.8 MBTUH Cooling
:57.9 MBTUH
4.84KW
GEHB048 TRANE 6 Heating :57 MBTUH Cooling
:47.3 MBTUH
4.27KW
GEHB042 TRANE 5 Heating :48.5 MBTUH Cooling
:39.5 MBTUH
3.46KW
GEHB030 TRANE 1 Heating :33.5 MBTUH Cooling
:28.1 MBTUH
2.33KW
GEHB024 TRANE 2 Heating :31.0 MBTUH Cooling
:25.2 MBTUH
2.18KW
Q'ty
Specification
Remark
7170 Cooling Tower Type
Heat Pump
Circulation Pump
Heat Exchanger
Bldg. System Equipment Model Mfg
7171 Cooling Tower Type
Heat Pump
Circulation Pump
Heat Exchanger
GEHB018 TRANE 1 Heating :22.1 MBTUH Cooling
:18.6 MBTUH
1.54KW
GEHB015 TRANE 3 Heating :17.5 MBTUH Cooling
:13.8 MBTUH
1.09KW
GEHB009 TRANE 2 Heating : 11.1 MBTUH Cooling
: 8.9 MBTUH
0.72KW
WPWD072 TRANE 1 Heating :96.9 MBTUH Cooling
:58.2 MBTUH
4.34KW
WPWD060 TRANE 1 Heating :80.4 MBTUH Cooling
:52.5 MBTUH
3.93KW
Capacity Power Consumption
WPWD042 TRANE 1 Heating :55.9 MBTUH Cooling
:35.7 MBTUH
2.06KW
WPWD036 TRANE 1 Heating :46.9 MBTUH Cooling
:30.5 MBTUH
1.72KW
WPWD024 TRANE 2 Heating :34.3 MBTUH Cooling
:20.6 MBTUH
1.79KW Hot Water
HRP‐S700‐W700 Dooil Engineering 2
HRP‐S600‐W700 Dooil Engineering 2
LPBO‐125/114 GRUNDFOS 2 5.6HP (220V/60Hz/3Ph) for geo‐thermal
TP50‐160/2 GRUNDFOS 2 1.5HP (220V/60Hz/3Ph) for condensing water on 1F
TP65‐190/4 GRUNDFOS 2 4HP (220V/60Hz/3Ph) for condensing water on 2F
TP32‐40/4 GRUNDFOS 1 1/3HP (220V/60Hz/3Ph) for WP(Hot Water)
TP32‐160/2 GRUNDFOS 4 3/4HP (220V/60Hz/3Ph) for HX
BSQ‐180‐15 MARATHON 1 1.5HP (220V/60Hz/3Ph)
BSQ‐180‐7 MARATHON 4 4/3HP (220V/60Hz/3Ph)
BSQ‐180‐10 MARATHON 3 1HP (220V/60Hz/3Ph)
Heat Pump
Bldg. System Equipment Model Mfg Q'ty
Specification
Remark
Heat Pump (Water to Water Heat Pump)
HX
(Air to Air Heat Exchanger)
Circulation Pump
Circulation Pump
Fan
E2907‐040C TPI CORPORATION 4 1 kW
E2906‐040C TPI CORPORATION 3 0.5 kW
D80 BELL&COSSETT 1 Maxium Working Pressure : 85 for HP piping loof
D20 BELL&COSSETT 4 Maxium Working Pressure : 85 for HX
Heating Water Coil 4 serviced with HX GEHB024 TRANE 6 Heating :31.0 MBTUH Cooling
:25.2 MBTUH
2.18KW
GEHB018 TRANE 1 Heating :22.1 MBTUH Cooling
:18.6 MBTUH
1.54KW
Heat Pump (Water to Water Heat Pump)
EXWA24041 TRANE 4 Heating :302.4 MBTUH Cooling
:191.4 MBTUH
Scroll Chiller CGWF0404 TRANE 1 40 TON
AHU MCCB040UA0AO
UA
TRANE 1
Fan Motor M2513T BALDOR 1 15HP (460V/3Ph/60Hz)
Fan Motor ADSMITH ADSMITH 1 7.5 HP (460V/3Ph/60Hz)
2 3Row, 11'‐6"
2 3Row, 10'‐6" VAV Unit 95
Capacity Power Consumption
Expansion Tank
4 Working Pressure : 862 ㎪Tank Volume : 19 ℓ
Coolingtower VF1096510 BALTIMORE 1 Cooling capacity : 671kW
M3313T BALDOR 2 10HP (460V/3Ph/60Hz)
M3211T BALDOR 2 3HP (460V/3Ph/60Hz) M3157T BALDOR 2 2HP (460V/3Ph/60Hz) M99084 MARATHON 1 2HP (460V/3Ph/60Hz) P6CKB‐2742 EMERSON 1 1HP (460V/3Ph/60Hz) S55CXJFM4927 EMERSON 2 0.5HP (115V/1Ph/60Hz)
2372 Geothermal Type
Baseboard Heater
Expansion Tank
2308 Cooling Tower Type
Heat Pump
Fin Tube Radiator
Bldg. System Equipment Model Mfg Q'ty
Specification
Remark
Pump
AHU DACD-3034 DATA-AIRE 1 496.3 MBTUH NOC Room
AHU DAAD-3034 DATA-AIRE 2 397.9 MBTUH NOC Room
Heat Pump GSUJ072 TRANE 1 Heating :83 MBTUH Cooling
:68.2 MBTUH
Circulation Pump LPK4B GRUNDFOS 1 1/4 HP (220volt/60HZ/1Ph)
Heat Pump GSUJ060 TRANE 1 Heating :73.5 MBTUH Cooling
:63.2 MBTUH
Circulation Pump LPK4B GRUNDFOS 1 1/4 HP (220volt/60HZ/1Ph)
Heat Pump GSUJ060 TRANE 1 Heating :73.5 MBTUH Cooling
:63.2 MBTUH
Circulation Pump LPK4B GRUNDFOS 1 1/4 HP (220volt/60HZ/1Ph)
Heat Pump GSUJ072 TRANE 1 Heating :83 MBTUH Cooling
:68.2 MBTUH
Circulation Pump LPK4B GRUNDFOS 1 1/4 HP (220volt/60HZ/1Ph)
Heat Pump GSUJ060 TRANE 1 Heating :73.5 MBTUH Cooling
:63.2 MBTUH
Circulation Pump LPK4B GRUNDFOS 1 1/4 HP (220volt/60HZ/1Ph)
Heat Pump GSUJ060 TRANE 1 Heating :73.5 MBTUH Cooling
:63.2 MBTUH
Circulation Pump LPK4B GRUNDFOS 1 1/4 HP (220volt/60HZ/1Ph)
Heat Pump GSUJ060 TRANE 1 Heating :73.5 MBTUH Cooling
:63.2 MBTUH
Circulation Pump LPK4B GRUNDFOS 1 1/4 HP (220volt/60HZ/1Ph)
Heat Pump GSUJ072 TRANE 2 Heating :83 MBTUH Cooling
:68.2 MBTUH
Circulation Pump LPK4B GRUNDFOS 2 1/4 HP (220volt/60HZ/1Ph)
EMD048‐1H2C FLORIDA H/P 2
EMD036‐1H2C FLORIDA H/P 1
Circulation Pump 4
Cooled Air Type
Geothermal Type
7069A/B
Heat Pump
Table 1