amend04Vista Construction Questions Num 2.docx
DOCX document 14 KB Posted
- Solicitation number
- AG-9702-S-10-0347
About this file
Questions and answers
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Schedule of Items061510.docx | DOCX document | |
| SF30-005-06-15.rtf | RTF text file | |
| SF30-004-06-01-2010_SEC.rtf | RTF text file | |
| amend04DTLS_SHEETS L-5.pdf | ||
| amend04Schedule of Items.docx | DOCX document | |
| SF30-003-06-01-2010_SEC.rtf | RTF text file | |
| Schedule of Items.docx | DOCX document | |
| Traffic Control Plan Special Provision Sect 702-A 2004.pdf | ||
| Drawings Addendum 060310.pdf | ||
| Vista Construction Questions Num 1.docx | DOCX document | |
| SF30-002-06-01-2010_SEC.rtf | RTF text file | |
| CONSTRUCTION_RFP.doc | DOC document | |
| REVISEDSchedule of Items 052110.pdf | ||
| SF30_SEC.rtf | RTF text file | |
| 7 - MCT Drawings.pdf | ||
| 1 - MCT Vista Specification and Drawing Listing.pdf | ||
| 5 - MCT Vista Interpretive Plan.pdf | ||
| 3 - MCT Vista Specs Vol I.pdf | ||
| Bid Bond_Standard_Form_24.pdf | ||
| CONSTRUCTION_RFP.doc | DOC document | |
| 2 - MCT Vista FP03 Supplement.pdf | ||
| 4 - MCT Vista Specs Vol II Roadway.pdf |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Mexican Canyon Trestle Clarifications and Answers to Questions
Drawings
· Corrected references on sheets L-5
Schedule
· Added site entrance signs: one for east bound traffic and one for west bound traffic.
· Added “Type 1-A” to the drop inlet item.
Questions
1. Rail details do not specify wall thickness of steel tubes. What is required?
ANSWER: The steel posts are HSS3x3x3/16
2. Sheet L5 Sections A-A & plan 4 call for 1" steel grating. Sheet L5 Section 7 calls for aluminum grating. Sheet S2.0 framing plan calls for 3/4" steel grating. Which is correct?
ANSWER: Use 3/4" steel grating
3. There is a note @ Detail 1, Sheet L-5 just below the section cut calling for 3 x 1/4" plate steel. What is this referring to?
ANSWER: See revised Sheet L-5; the callout was deleted.
4. Handrail notes @ detail 1 & 3 Sheet L-5 call for 1x1 1/4" tube top rail. @ plan 4 calls for 4x1 1/2" Tube. 4x1 1/2" is more readily available. Is this acceptable?
ANSWER: Structurally 4"x 1 1/2" is acceptable for top rail
5. How will the stream crossing be paid for?
ANSWER: The stream crossing is considered incidental to trail construction.
6. Will you allow the use of SPIV in lieu of the SPIII called out in the bid items?
ANSWER: Use SP III in your proposal; we may consider SP IV after award.
7. Can you provide more details or a standard reference for the drop inlet? The detail shown on sheet 39 (sub sheet PP) doesn’t detail the grate, rebar, etc. Can you please provide?
ANSWER: Use NMDOT Type 1-A drop inlet.