VC and GMAC
| Facility Management Software System | ||||||||||||||||||
| Asset Detail (Excel) for Structural Fire | ||||||||||||||||||
| Asset | Asset Description | Location | Location Description | Facility Type | Park | Region | Occupant | Classification | Quantity | Unit of Measure | Replacement Cost | Installation Date | Replacement Date | Manufacturer Description | Brand | Model | Serial Number | Comments |
| 1167099 | Alarm Sys, Fire, PVC, 7,000.0 SF, VC Lobby | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / ALARM / FRALMSIG | 40 | EA | $11,881.00 | 01/01/2006 | 01/01/2016 | |||||
| 487777 | Alarm Sys, Fire, 107000 SF, Controllers | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / ALARM / FRALMSIG | 73 | EA | $44,664.00 | 01/10/2007 | 01/01/2028 | |||||
| 1635433 | Fixed Fire Suppression System, Watermist Sprinkler System, Vestibule Room 105 Sprinkler Main GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/18/2018 | 02/18/2038 | Vestibule Room 105 Sprinkler Main GRG | ||||
| 1635436 | Fire Sprinkler System, Wet Pipe, Zone 19 West Entry Side Wall Sprinkler Heads GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 10 | EA | $1.00 | 02/18/2018 | 02/18/2028 | Zone 19 West Entry Side Wall Sprinkler Heads GRG | ||||
| 1635480 | Fire Sprinkler System, Dry Pipe, Zone 19 Flow Switch Near South handicap door GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $1.00 | 02/18/2018 | 02/02/2038 | Zone 19 Flow Switche Near South handicap door GRG | ||||
| 1635481 | Standpipe, Class I - Fire Department Use, Zone19 Standpipe Hose Cabnt South door West GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / STNDPIPE | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone19 Standpipe Hose Cabnt South door West GRG | ||||
| 1635482 | Fixed Fire Suppression System, Watermist Sprinkler System, Zone19 Dry Pipe Valve W s door GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone19 Dry Pipe Valve W s door GRG | ||||
| 1635483 | Fixed Fire Suppression System, Zone 18 4" fire protection Riser to Mezzanine GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone 18 4" fire protection Riser to Mezzanine GRG | ||||
| 1635484 | Fixed Fire Suppression System, Zone 18 Stand Pipe Hose Valve Cabinet by S escalator GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $0.00 | 02/02/2018 | 02/02/2038 | Zone 18 Stand Pipe Hose Valve Cabinet by S escalator GRG | ||||
| 1635485 | Fixed Fire Suppression System, Zone 18 Flow Switch GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $0.00 | 02/02/2018 | 02/02/2038 | Zone 18 Flow Switch GRG | ||||
| 1635486 | Fire Sprinkler System, Wet Pipe, Zone 18 Typical Concealed sprinkler heads Guard/firstaid GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 26 | EA | $1.00 | N/A | 02/02/2028 | Zone 18 Typical Concealed sprinkler heads Guard/firstaid GRG | ||||
| 1635487 | Fire Sprinkler System, Wet Pipe, Zone 18 Typical Concealed sprinkler heads GRG Screening area | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 16 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 18 Typical Concealed sprinkler heads GRG Screening area | ||||
| 1635494 | Fire Sprinkler System, Wet Pipe, Zone 17 Typical Concealed sprinkler heads GRG Queing office and rr | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 47 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 17 Typical Concealed sprinkler heads GRG Queing office and rr lg heads | ||||
| 1635496 | Fire Sprinkler System, Wet Pipe, Zone 17 Typical Concealed sprinkler heads GRG Metro307 and room 304 | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 5 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 17 Typical Concealed sprinkler heads GRG Metro307 and room 304A | ||||
| 1635500 | Fixed Fire Suppression System, Watermist Sprinkler System, Zone 17 Flow Switch GRG outside of RM 304 | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone 17 Flow Switch GRG outside of RM 304A | ||||
| 1635505 | Standpipe, Class I - Fire Department Use, Zone 17 Stand Pipe Hose Valve Cabinet outside rm 304A GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / STNDPIPE | 1 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 17 Stand Pipe Hose Valve Cabinet outside rm 304A GRG | ||||
| 1635509 | Fixed Fire Suppression System, Zone 17 4" fire protection Riser Northto Mezzanine GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | N/A | 02/02/2038 | Zone 17 4" fire protection Riser Northto Mezzanine GRG | ||||
| 1635512 | Standpipe, Class I - Fire Department Use, Zone17 StandPipe HoseValve Cab exteriorStair 2STC GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / STNDPIPE | 1 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone17 StandPipe HoseValve Cab exteriorStair 2STC GRG | ||||
| 1635571 | Fixed Fire Suppression System, Watermist Sprinkler System, Zone 17 Flow Switch GRG in hall to stair | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone 17 Flow Switch GRG in hall to stair 2STC | ||||
| 1635591 | Fire Sprinkler System, Wet Pipe, Zone 14 Typical Concealed sprinkler heads GRG Lobby Area | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 46 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 14 Typical Concealed sprinkler heads GRG Lobby Area | ||||
| 1635594 | Fire Sprinkler System, Wet Pipe, Zone 13 Typical Concealed sprinkler heads GRG Mezzanine Area | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 60 | EA | $1.00 | N/A | 02/02/2028 | Zone 13 Typical Concealed sprinkler heads GRG Mezzanine Area | ||||
| 1635599 | Fire Sprinkler System, Wet Pipe, Zone 15 Typical Concealed sprinkler heads GRG RMs 201 Lg heads | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 4 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 15 Typical Concealed sprinkler heads GRG RMs 201 Lg heads | ||||
| 1635600 | Fire Sprinkler System, Wet Pipe, Zone 15 Typical Concealed sprinkler heads GRG RMs 202 sm heads | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 7 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 15 Typical Concealed sprinkler heads GRG RMs 202 sm heads | ||||
| 1635601 | Fire Sprinkler System, Wet Pipe, Zone 16 Typical Concealed sprinkler heads GRG RR Lg heads | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 6 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 16 Typical Concealed sprinkler heads GRG RR Lg heads | ||||
| 1636674 | Fire Sprinkler System, Wet Pipe, Zone 12 Typical Concealed Lg sprinkler heads GRG museum entrance | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 45 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 12 Typical Concealed Lg sprinkler heads GRG museum entrance | ||||
| 1636676 | Fire Sprinkler System, Wet Pipe, Fire Sprinkler System, Wet Pipe, Zone12 sidewall heads GRG museum | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 3 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Fire Sprinkler System, Wet Pipe, Zone12 sidewall heads GRG museum ent | ||||
| 1636686 | Standpipe, Class I - Fire Department Use, Zone12 StandPipeHoseValve Cabinet at transition wall to mu | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / STNDPIPE | 2 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone12 StandPipeHoseValve Cabinet at transition wall to mus GRG | ||||
| 1636692 | Fire Hydrant, Wet Barrel, 6.0 IN, Zone 1 Fire Department Connection after check valve pump RM | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / HYDRANT | 1 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 1 Fire Department Connection after check valve pump RM | ||||
| 1636712 | Fire Sprinkler System, Wet Pipe, Zone1 Pendant Head Sprinklers N service hall GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 8 | EA | $1.00 | 02/02/2018 | 02/02/2023 | Zone1 Pendant Head Sprinklers N service hall GRG | ||||
| 1636714 | Fire Sprinkler System, Wet Pipe, Zone 1 Upright Sprinkler Heads In Mueum | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 138 | EA | $1.00 | 02/02/2018 | 02/02/2023 | Zone 1 Upright Sprinkler Heads In Mueum | ||||
| 1636716 | Fire Sprinkler System, Wet Pipe, Zone 1 side wall sprinklers in Corridor 109A S hall GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 9 | EA | $1.00 | 02/02/2018 | 02/02/2023 | Zone 1 side wall sprinklers in Corridor 109A S hall GRG | ||||
| 1636717 | Fire Sprinkler System, Wet Pipe, Zone 1 concealed sprinklers in museum entrance 1 in NE corner | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 5 | EA | $1.00 | 02/02/2018 | 02/02/2023 | Zone 1 concealed sprinklers at museum entrance 1 in NE corner | ||||
| 1637492 | Fire Sprinkler System, Wet Pipe, Zone 2 concealed head | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 80 | EA | $1.00 | 02/01/2018 | 02/11/2018 | Zone 2 concealed head | ||||
| 1637559 | Fire Sprinkler System, Wet Pipe, Zone 5 Concealed sprinkler heads | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 192 | EA | $1.00 | 02/01/2018 | 02/01/2028 | Zone 5 Concealed sprinkler heads | ||||
| 1637563 | Fire Sprinkler System, Wet Pipe, Zone 4 Concealed sprinkler heads | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 24 | EA | $1.00 | 02/01/2018 | 02/01/2028 | Zone 4 Concealed sprinkler heads | ||||
| 1637568 | Fire Sprinkler System, Wet Pipe, Zone 4 Pendent sprinkler heads GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 39 | EA | $0.00 | N/A | 02/01/2028 | Zone 4 Pendent sprinkler heads GRG | ||||
| 1683481 | Fire Sprinkler System, Wet Pipe, Zone 6 Pendent sprinkler heads Concessions GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 35 | EA | $0.00 | N/A | 02/01/2028 | Zone6 Pendent sprinkler heads Concessions GRG | ||||
| 1683482 | Fire Sprinkler System, Wet Pipe, Zone 6 Recessed sprinkler heads Concessions GRG | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 12 | EA | $0.00 | N/A | 02/01/2028 | Zone 6 Recessed sprinkler heads Concessions GRG | ||||
| 1697692 | Lighting, Emergency, Other, 120V, Bi-State LED Rope Lighting under Stainless Steel ramp walls, Other | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | ELECTRCL / LIGHT | 2 | EA | $16,976.61 | 03/01/2016 | 03/01/2028 | |||||
| 400091 | Fire Extinguishing Sys, Deluge/Preaction, 107000 SF, 4" Iron Pipe | 19274 | Arch Visitor Center | 4129 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $214,000.00 | 01/01/1965 | 01/01/2040 | |||||
| 1265723 | Alarm Sys, Fire, Fire and Heat Detectors Grds | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / ALARM / FRALMSIG | 1 | EA | $100,000.00 | 10/01/2002 | 10/01/2022 | |||||
| 1676855 | Smoke Alarm System, Smoke Sensors Fire Suppression System GRG | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / ALARM / SMKALSYS | 18 | EA | $4,000.00 | 02/04/2015 | 02/04/2030 | |||||
| 1755004 | Fire Alarm Signaling System, Addressable, 75 Candela fire alarm w/strobe GRDS 1st FL | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / ALARM / FRALMSIG | 10 | EA | $0.00 | 02/07/2002 | 04/20/2022 | |||||
| 1755005 | Fire Alarm Signaling System, Addressable, 110 Candela fire alarm w/strobe GRDS 1st FL | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / ALARM / FRALMSIG | 6 | EA | $0.00 | 04/20/2002 | 04/20/2022 | |||||
| 1755006 | Fire Alarm Signaling System, Addressable, 110 Candela fire alarm w/strobe GRDS basement | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / ALARM / FRALMSIG | 2 | EA | $0.00 | 04/02/2002 | 04/20/2022 | |||||
| 1755007 | Fire Alarm Signaling System, Addressable, Pull stations in main corridor 1st fl | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / ALARM / FRALMSIG | 2 | EA | $0.00 | 04/20/2002 | 04/20/2007 | |||||
| 1757469 | Smoke Management and Control System, Dedicated, Fire Alarm System Back Up Batteries | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SMKMNGCT | 2 | EA | $0.00 | 01/01/2016 | 01/01/2021 | |||||
| 1757471 | Smoke Alarm System, Hardwired Interconnected, Dedicated, Smoke Detector WO Sensitivity | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / ALARM / SMKALSYS | 7 | EA | $0.00 | 01/01/2011 | 01/01/2023 | |||||
| 385725 | Fire Alarm Signaling System, Addressable, Restorable, Heat and Smoke GRDS | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / ALARM / FRALMSIG | 1 | EA | $7,315.00 | 09/01/2002 | 09/01/2017 | |||||
| 1574328 | Fire Sprinkler System, Wet Pipe GPM, 4.0 IN, GMAC | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $3,600.00 | 06/01/2016 | 06/01/2046 | |||||
| 1596655 | Fixed Fire Suppression System, GRG Fire Supression system Ranger Substation | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 10/01/2016 | 01/01/2041 | |||||
| 1676851 | Fixed Fire Suppression System | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 12 | EA | $5,000.00 | 02/04/2015 | 02/04/2030 | |||||
| 1676859 | Strobe lights Fire Suppression System GRG | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 5 | EA | $4,000.00 | 02/04/2018 | 02/04/2030 | |||||
| 1676865 | Fixed Fire Suppression System | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 5 | EA | $0.00 | N/A | 02/04/2030 | |||||
| 1676869 | Switches Fixed Fire Suppression System | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 2 | EA | $2,000.00 | 02/04/2015 | 02/04/2030 | |||||
| 1676873 | Components Fixed Fire Suppression System GRG | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRESUPP | 61 | EA | $2,000.00 | 02/04/2015 | 02/04/2030 | |||||
| 1754990 | Fire Sprinkler System, Wet Pipe, dry pendant sidewall GRG | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 9 | EA | $540.00 | 01/01/2014 | 01/01/2019 | |||||
| 1754991 | Fire Sprinkler System, ceiling mount upright GRG | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 22 | EA | $1,012.00 | 01/01/2014 | 01/01/2019 | |||||
| 1754992 | Fire Sprinkler System, Wet Pipe, Extend Cover Brass UPright 1st Fl | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 42 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1754993 | Fire Sprinkler System, Wet Pipe, Extend Cover Brass UPright basement | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 27 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1754994 | Fire Sprinkler System, Wet Pipe, Extend Cover Brass UPright 1st Fl | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 26 | EA | $0.00 | N/A | 03/08/2022 | |||||
| 1754995 | Fire Sprinkler System, Wet Pipe, Quick Response Brass Upright 1st Fl | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 5 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1754996 | Fire Sprinkler System, Wet Pipe, Quick Response recessed chrome pendent 1st Fl | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 17 | EA | $0.00 | 03/12/2022 | 03/08/2022 | |||||
| 1754997 | Fire Sprinkler System, Wet Pipe, Dry Horizontal 1st Fl | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 6 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1754999 | Fire Sprinkler System, Wet Pipe, Extend Cover Recess Chrome basement | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 2 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1755000 | Fire Sprinkler System, Wet Pipe, Quick response Brass Upright basement | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 7 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1755001 | Fire Sprinkler System, Wet Pipe, Quick response chrome Upright basement | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1755002 | Fire Sprinkler System, Wet Pipe, Dry Horizontal sidewall basement | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 2 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1755003 | Fire Sprinkler System, Wet Pipe, Dry Horizontal sidewall basement | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | EA | $0.00 | 03/08/2012 | 03/08/2022 | ||||||
| 1757474 | Smoke Management and Control System, Dedicated, Pull Stations | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SMKMNGCT | 8 | EA | $0.00 | 01/01/2011 | 01/01/2016 | |||||
| 385715 | Fire Extinguishing Sys, Wet Pipe, 23500 SF, GMSC | 19288 | Grounds Maint Complex and Warehouse Building | 4160 | JEFF | MWR | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $61,330.00 | 09/01/2002 | 09/01/2022 |
19274 Arch VC
| Facility Management Software System | |||||||||||||||||
| Asset Detail (Excel) for Structural Fire | |||||||||||||||||
| Asset | Asset Description | Location | Location Description | Facility Type | Park | Occupant | Classification | Quantity | Unit of Measure | Replacement Cost | Installation Date | Replacement Date | Manufacturer Description | Brand | Model | Serial Number | Comments |
| 1167099 | Alarm Sys, Fire, PVC, 7,000.0 SF, VC Lobby | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / ALARM / FRALMSIG | 40 | EA | $11,881.00 | 01/01/2006 | 01/01/2016 | |||||
| 487777 | Alarm Sys, Fire, 107000 SF, Controllers | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / ALARM / FRALMSIG | 73 | EA | $44,664.00 | 01/10/2007 | 01/01/2028 | |||||
| 1635433 | Fixed Fire Suppression System, Watermist Sprinkler System, Vestibule Room 105 Sprinkler Main GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/18/2018 | 02/18/2038 | Vestibule Room 105 Sprinkler Main GRG | ||||
| 1635436 | Fire Sprinkler System, Wet Pipe, Zone 19 West Entry Side Wall Sprinkler Heads GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 10 | EA | $1.00 | 02/18/2018 | 02/18/2028 | Zone 19 West Entry Side Wall Sprinkler Heads GRG | ||||
| 1635480 | Fire Sprinkler System, Dry Pipe, Zone 19 Flow Switch Near South handicap door GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $1.00 | 02/18/2018 | 02/02/2038 | Zone 19 Flow Switche Near South handicap door GRG | ||||
| 1635481 | Standpipe, Class I - Fire Department Use, Zone19 Standpipe Hose Cabnt South door West GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / STNDPIPE | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone19 Standpipe Hose Cabnt South door West GRG | ||||
| 1635482 | Fixed Fire Suppression System, Watermist Sprinkler System, Zone19 Dry Pipe Valve W s door GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone19 Dry Pipe Valve W s door GRG | ||||
| 1635483 | Fixed Fire Suppression System, Zone 18 4" fire protection Riser to Mezzanine GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone 18 4" fire protection Riser to Mezzanine GRG | ||||
| 1635484 | Fixed Fire Suppression System, Zone 18 Stand Pipe Hose Valve Cabinet by S escalator GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $0.00 | 02/02/2018 | 02/02/2038 | Zone 18 Stand Pipe Hose Valve Cabinet by S escalator GRG | ||||
| 1635485 | Fixed Fire Suppression System, Zone 18 Flow Switch GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $0.00 | 02/02/2018 | 02/02/2038 | Zone 18 Flow Switch GRG | ||||
| 1635486 | Fire Sprinkler System, Wet Pipe, Zone 18 Typical Concealed sprinkler heads Guard/firstaid GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 26 | EA | $1.00 | N/A | 02/02/2028 | Zone 18 Typical Concealed sprinkler heads Guard/firstaid GRG | ||||
| 1635487 | Fire Sprinkler System, Wet Pipe, Zone 18 Typical Concealed sprinkler heads GRG Screening area | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 16 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 18 Typical Concealed sprinkler heads GRG Screening area | ||||
| 1635494 | Fire Sprinkler System, Wet Pipe, Zone 17 Typical Concealed sprinkler heads GRG Queing office and rr | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 47 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 17 Typical Concealed sprinkler heads GRG Queing office and rr lg heads | ||||
| 1635496 | Fire Sprinkler System, Wet Pipe, Zone 17 Typical Concealed sprinkler heads GRG Metro307 and room 304 | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 5 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 17 Typical Concealed sprinkler heads GRG Metro307 and room 304A | ||||
| 1635500 | Fixed Fire Suppression System, Watermist Sprinkler System, Zone 17 Flow Switch GRG outside of RM 304 | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone 17 Flow Switch GRG outside of RM 304A | ||||
| 1635505 | Standpipe, Class I - Fire Department Use, Zone 17 Stand Pipe Hose Valve Cabinet outside rm 304A GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / STNDPIPE | 1 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 17 Stand Pipe Hose Valve Cabinet outside rm 304A GRG | ||||
| 1635509 | Fixed Fire Suppression System, Zone 17 4" fire protection Riser Northto Mezzanine GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | N/A | 02/02/2038 | Zone 17 4" fire protection Riser Northto Mezzanine GRG | ||||
| 1635512 | Standpipe, Class I - Fire Department Use, Zone17 StandPipe HoseValve Cab exteriorStair 2STC GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / STNDPIPE | 1 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone17 StandPipe HoseValve Cab exteriorStair 2STC GRG | ||||
| 1635571 | Fixed Fire Suppression System, Watermist Sprinkler System, Zone 17 Flow Switch GRG in hall to stair | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 02/02/2018 | 02/02/2038 | Zone 17 Flow Switch GRG in hall to stair 2STC | ||||
| 1635591 | Fire Sprinkler System, Wet Pipe, Zone 14 Typical Concealed sprinkler heads GRG Lobby Area | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 46 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 14 Typical Concealed sprinkler heads GRG Lobby Area | ||||
| 1635594 | Fire Sprinkler System, Wet Pipe, Zone 13 Typical Concealed sprinkler heads GRG Mezzanine Area | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 60 | EA | $1.00 | N/A | 02/02/2028 | Zone 13 Typical Concealed sprinkler heads GRG Mezzanine Area | ||||
| 1635599 | Fire Sprinkler System, Wet Pipe, Zone 15 Typical Concealed sprinkler heads GRG RMs 201 Lg heads | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 4 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 15 Typical Concealed sprinkler heads GRG RMs 201 Lg heads | ||||
| 1635600 | Fire Sprinkler System, Wet Pipe, Zone 15 Typical Concealed sprinkler heads GRG RMs 202 sm heads | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 7 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 15 Typical Concealed sprinkler heads GRG RMs 202 sm heads | ||||
| 1635601 | Fire Sprinkler System, Wet Pipe, Zone 16 Typical Concealed sprinkler heads GRG RR Lg heads | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 6 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 16 Typical Concealed sprinkler heads GRG RR Lg heads | ||||
| 1636674 | Fire Sprinkler System, Wet Pipe, Zone 12 Typical Concealed Lg sprinkler heads GRG museum entrance | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 45 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 12 Typical Concealed Lg sprinkler heads GRG museum entrance | ||||
| 1636676 | Fire Sprinkler System, Wet Pipe, Fire Sprinkler System, Wet Pipe, Zone12 sidewall heads GRG museum | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 3 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Fire Sprinkler System, Wet Pipe, Zone12 sidewall heads GRG museum ent | ||||
| 1636686 | Standpipe, Class I - Fire Department Use, Zone12 StandPipeHoseValve Cabinet at transition wall to mu | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / STNDPIPE | 2 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone12 StandPipeHoseValve Cabinet at transition wall to mus GRG | ||||
| 1636692 | Fire Hydrant, Wet Barrel, 6.0 IN, Zone 1 Fire Department Connection after check valve pump RM | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / HYDRANT | 1 | EA | $1.00 | 02/02/2018 | 02/02/2028 | Zone 1 Fire Department Connection after check valve pump RM | ||||
| 1636712 | Fire Sprinkler System, Wet Pipe, Zone1 Pendant Head Sprinklers N service hall GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 8 | EA | $1.00 | 02/02/2018 | 02/02/2023 | Zone1 Pendant Head Sprinklers N service hall GRG | ||||
| 1636714 | Fire Sprinkler System, Wet Pipe, Zone 1 Upright Sprinkler Heads In Mueum | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 138 | EA | $1.00 | 02/02/2018 | 02/02/2023 | Zone 1 Upright Sprinkler Heads In Mueum | ||||
| 1636716 | Fire Sprinkler System, Wet Pipe, Zone 1 side wall sprinklers in Corridor 109A S hall GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 9 | EA | $1.00 | 02/02/2018 | 02/02/2023 | Zone 1 side wall sprinklers in Corridor 109A S hall GRG | ||||
| 1636717 | Fire Sprinkler System, Wet Pipe, Zone 1 concealed sprinklers in museum entrance 1 in NE corner | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 5 | EA | $1.00 | 02/02/2018 | 02/02/2023 | Zone 1 concealed sprinklers at museum entrance 1 in NE corner | ||||
| 1637492 | Fire Sprinkler System, Wet Pipe, Zone 2 concealed head | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 80 | EA | $1.00 | 02/01/2018 | 02/11/2018 | Zone 2 concealed head | ||||
| 1637559 | Fire Sprinkler System, Wet Pipe, Zone 5 Concealed sprinkler heads | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 192 | EA | $1.00 | 02/01/2018 | 02/01/2028 | Zone 5 Concealed sprinkler heads | ||||
| 1637563 | Fire Sprinkler System, Wet Pipe, Zone 4 Concealed sprinkler heads | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 24 | EA | $1.00 | 02/01/2018 | 02/01/2028 | Zone 4 Concealed sprinkler heads | ||||
| 1637568 | Fire Sprinkler System, Wet Pipe, Zone 4 Pendent sprinkler heads GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 39 | EA | $0.00 | N/A | 02/01/2028 | Zone 4 Pendent sprinkler heads GRG | ||||
| 1683481 | Fire Sprinkler System, Wet Pipe, Zone 6 Pendent sprinkler heads Concessions GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 35 | EA | $0.00 | N/A | 02/01/2028 | Zone6 Pendent sprinkler heads Concessions GRG | ||||
| 1683482 | Fire Sprinkler System, Wet Pipe, Zone 6 Recessed sprinkler heads Concessions GRG | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 12 | EA | $0.00 | N/A | 02/01/2028 | Zone 6 Recessed sprinkler heads Concessions GRG | ||||
| 1697692 | Lighting, Emergency, Other, 120V, Bi-State LED Rope Lighting under Stainless Steel ramp walls, Other | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | ELECTRCL / LIGHT | 2 | EA | $16,976.61 | 03/01/2016 | 03/01/2028 | |||||
| 400091 | Fire Extinguishing Sys, Deluge/Preaction, 107000 SF, 4" Iron Pipe | 19274 | Arch Visitor Center | 4129 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $214,000.00 | 01/01/1965 | 01/01/2040 |
19288 Grds Complex
| Facility Management Software System | |||||||||||||||||
| Asset Detail (Excel) for Structural Fire | |||||||||||||||||
| Asset | Asset Description | Location | Location Description | Facility Type | Park | Occupant | Classification | Quantity | Unit of Measure | Replacement Cost | Installation Date | Replacement Date | Manufacturer Description | Brand | Model | Serial Number | Comments |
| 1265723 | Alarm Sys, Fire, Fire and Heat Detectors Grds | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / FRALMSIG | 1 | EA | $100,000.00 | 10/01/2002 | 10/01/2022 | |||||
| 1676855 | Smoke Alarm System, Smoke Sensors Fire Suppression System GRG | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / SMKALSYS | 18 | EA | $4,000.00 | 02/04/2015 | 02/04/2030 | |||||
| 1755004 | Fire Alarm Signaling System, Addressable, 75 Candela fire alarm w/strobe GRDS 1st FL | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / FRALMSIG | 10 | EA | $0.00 | 02/07/2002 | 04/20/2022 | |||||
| 1755005 | Fire Alarm Signaling System, Addressable, 110 Candela fire alarm w/strobe GRDS 1st FL | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / FRALMSIG | 6 | EA | $0.00 | 04/20/2002 | 04/20/2022 | |||||
| 1755006 | Fire Alarm Signaling System, Addressable, 110 Candela fire alarm w/strobe GRDS basement | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / FRALMSIG | 2 | EA | $0.00 | 04/02/2002 | 04/20/2022 | |||||
| 1755007 | Fire Alarm Signaling System, Addressable, Pull stations in main corridor 1st fl | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / FRALMSIG | 2 | EA | $0.00 | 04/20/2002 | 04/20/2007 | |||||
| 1757469 | Smoke Management and Control System, Dedicated, Fire Alarm System Back Up Batteries | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SMKMNGCT | 2 | EA | $0.00 | 01/01/2016 | 01/01/2021 | |||||
| 1757471 | Smoke Alarm System, Hardwired Interconnected, Dedicated, Smoke Detector WO Sensitivity | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / SMKALSYS | 7 | EA | $0.00 | 01/01/2011 | 01/01/2023 | |||||
| 1757472 | Smoke Alarm System, Hardwired Interconnected, Heat Detector elevator Mech Rm and shaft | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / SMKALSYS | 2 | EA | $0.00 | 01/01/2016 | 01/01/2021 | |||||
| 385725 | Fire Alarm Signaling System, Addressable, Restorable, Heat and Smoke GRDS | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / ALARM / FRALMSIG | 1 | EA | $7,315.00 | 09/01/2002 | 09/01/2017 | |||||
| 1574328 | Fire Sprinkler System, Wet Pipe GPM, 4.0 IN, GMAC | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $3,600.00 | 06/01/2016 | 06/01/2046 | |||||
| 1596655 | Fixed Fire Suppression System, GRG Fire Supression system Ranger Substation | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 1 | EA | $1.00 | 10/01/2016 | 01/01/2041 | |||||
| 1676851 | Fixed Fire Suppression System | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 12 | EA | $5,000.00 | 02/04/2015 | 02/04/2030 | |||||
| 1676859 | Strobe lights Fire Suppression System GRG | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 5 | EA | $4,000.00 | 02/04/2018 | 02/04/2030 | |||||
| 1676865 | Fixed Fire Suppression System | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 5 | EA | $0.00 | N/A | 02/04/2030 | |||||
| 1676869 | Switches Fixed Fire Suppression System | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 2 | EA | $2,000.00 | 02/04/2015 | 02/04/2030 | |||||
| 1676873 | Components Fixed Fire Suppression System GRG | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRESUPP | 61 | EA | $2,000.00 | 02/04/2015 | 02/04/2030 | |||||
| 1754990 | Fire Sprinkler System, Wet Pipe, dry pendant sidewall GRG | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 9 | EA | $540.00 | 01/01/2014 | 01/01/2019 | |||||
| 1754991 | Fire Sprinkler System, ceiling mount upright GRG | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 22 | EA | $1,012.00 | 01/01/2014 | 01/01/2019 | |||||
| 1754992 | Fire Sprinkler System, Wet Pipe, Extend Cover Brass UPright 1st Fl | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 42 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1754993 | Fire Sprinkler System, Wet Pipe, Extend Cover Brass UPright basement | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 27 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1754994 | Fire Sprinkler System, Wet Pipe, Extend Cover Brass UPright 1st Fl | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 26 | EA | $0.00 | N/A | 03/08/2022 | |||||
| 1754995 | Fire Sprinkler System, Wet Pipe, Quick Response Brass Upright 1st Fl | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 5 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1754996 | Fire Sprinkler System, Wet Pipe, Quick Response recessed chrome pendent 1st Fl | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 17 | EA | $0.00 | 03/12/2022 | 03/08/2022 | |||||
| 1754997 | Fire Sprinkler System, Wet Pipe, Dry Horizontal 1st Fl | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 6 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1754999 | Fire Sprinkler System, Wet Pipe, Extend Cover Recess Chrome basement | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 2 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1755000 | Fire Sprinkler System, Wet Pipe, Quick response Brass Upright basement | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 7 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1755001 | Fire Sprinkler System, Wet Pipe, Quick response chrome Upright basement | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1755002 | Fire Sprinkler System, Wet Pipe, Dry Horizontal sidewall basement | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 2 | EA | $0.00 | 03/08/2012 | 03/08/2022 | |||||
| 1755003 | Fire Sprinkler System, Wet Pipe, Dry Horizontal sidewall basement | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | EA | $0.00 | 03/08/2012 | 03/08/2022 | ||||||
| 1757474 | Smoke Management and Control System, Dedicated, Pull Stations | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SMKMNGCT | 8 | EA | $0.00 | 01/01/2011 | 01/01/2016 | |||||
| 385715 | Fire Extinguishing Sys, Wet Pipe, 23500 SF, GMSC | 19288 | Grounds Complex and Warehouse BLDG | 4160 | JEFF | NPS | SAFETY / SUPPRSSN / FIRSPRNK | 1 | EA | $61,330.00 | 09/01/2002 | 09/01/2022 |