A 03 Final Dwgs_Small Arms Range.pdf
PDF 15 MB Posted
- Attached to
- Small Arms Range
- Solicitation number
- W912LM21R1001
About this file
This document provides details for a federal contract solicitation for small arms range construction services. The U.S. Property and Fiscal Office for Minnesota is seeking a firm fixed-price contract for all labor, materials, equipment, and supervision to construct a manufactured containerized small arms range and conventionally constructed Combat Arms Training and Maintenance facility attached to the range. The project scope includes site work, utilities, and all structural, architectural, mechanical, and electrical systems for both facilities. The contract value is between $5-10 million and work must be completed within 360 days of the notice to proceed. The solicitation number is W912LM21R1001 and responses are due June 22, 2021. The procurement is set aside for small businesses with a size standard of $39.5 million or less. A pre-proposal conference will be held on June 3, 2021 followed by a site visit at the 148th Fighter Wing Duluth Air National Guard Base in Minnesota.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION MAP
MINNESOTA AIR NATIONAL GUARD
DULUTH, MINNESOTA
FMKM 179063
CONSTRUCT SMALL
ARMS RANGE
CONTACTS
CLIENT
PROJECT MANAGER
CIVIL ENGINEER
ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
LHB, INC.
21 WEST SUPERIOR STREET, SUITE 500
DULUTH, MN 55802
PHONE: (218) 727-8446
CONTACT: CARALYN KIEPER
E-MAIL: CARALYN.KIEPER@LHBCORP.COM
LHB, INC.
21 WEST SUPERIOR STREET, SUITE 500
DULUTH, MN 55802
PHONE: (218) 727-8446
CONTACT: DAN SHAW
E-MAIL: DAN.SHAW@LHBCORP.COM
LHB, INC.
21 WEST SUPERIOR STREET, SUITE 500
DULUTH, MN 55802
PHONE: (218) 727-8446
CONTACT: CYNTHIA POIRIER
E-MAIL: CYNTHIA.POIRIER@LHBCORP.COM
LHB, INC.
21 WEST SUPERIOR STREET, SUITE 500
DULUTH, MN 55802
PHONE: (218) 727-8446
CONTACT: JENNIFER BABCOCK
E-MAIL: JENNIFER.BABCOCK@LHBCORP.COM
LHB, INC.
21 WEST SUPERIOR STREET, SUITE 500
DULUTH, MN 55802
PHONE: (218) 727-8446
CONTACT: STEWART CRAN
E-MAIL: STEWART.CRAN@LHBCORP.COM
LHB, INC.
21 WEST SUPERIOR STREET, SUITE 500
DULUTH, MN 55802
PHONE: (218) 727-8446
CONTACT: MARK VINCENT
E-MAIL: MARK.VINCENT@LHBCORP.COM
148TH FIGHTER WING MINNESOTA AIR NATIONAL GUARD
OFFICE OF THE BASE CIVIL ENGINEER
PHONE: (218) 788-7339
CONTACT: COR MAJ JOSEPH SOLBERG
BASE CIVIL ENGINEER
JOSEPH.V.SOLBERG.MIL@MAIL.MIL
RENDERING/ IMAGE
497499
H A
IN
E S
R D
230 240
230 240
P H
AN
TO
M D
R
IV
E
SCORPION DRIVE
R A
M P
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
THIS SQUARE APPEARS 1/2"x1/2"
ON FULL SIZE SHEETS
CLIENT:
DULUTH, MINNESOTA
148th FIGHTER WING
MINNESOTA AIR
NATIONAL GUARD
CONSTRUCT SMALL
ARMS RANGE
..\180940 MnANG - Construct Small Arms Range A20.rvt
FMKM179063
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
NO DATE ISSUED FOR
21 W. Superior St., Ste 500 | Duluth, MN 55802 | 218.727.8446
10/5/20 B3 FINAL SUBMITTAL
B
IM
/1
M n A
N G
C o n s tr u c t
S m a ll
A rm s R a n g e
/1
M n
A N
G
C o n s tr u c t S m a ll
A rm s R a n g e
A
.r v t
/2 /2
:5
:4
P
M
G001
10/5/20
CYNTHIA POIRIER
22021
CMK
CIP
180940
PROJECT TITLE SHEET
SHEET INDEX
SHEET
NO SHEET NAME
F001 FIRE PROTECTION COVER SHEET & PLAN
F101 FIRE ALARM PLAN
F102 FIRE ALARM SCHEDULES AND DIAGRAMS
P001 PLUMBING SYMBOLS AND ABBREVIATIONS
P110 UNDERSLAB PLUMBING PLAN
P111 PLUMBING PLAN
P601 PLUMBING SCHEDULES, DETAILS & CONTROLS
P911 PLUMBING RISER DIAGRAMS
M001 MECHANICAL SYMBOLS AND ABBREVIATIONS
M151 VENTILATION PLANS
M201 MECHANICAL ROOF PLAN
M601 MECHANICAL SCHEDULES
M701 SYSTEM DETAILS AND CONTROLS 1 OF 2
M702 SYSTEM DETAILS AND CONTROLS 2 OF 2
E001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
E002 STANDARD INSTALLATION REQUIREMENTS
E003 STANDARD INSTALLATION REQUIREMENTS
ES101 ELECTRICAL SITE PLAN
E101 LIGHTNING PROTECTION PLAN
E102 LIGHTNING PROTECTION ROOF PLAN
EP101 POWER PLAN
T101 TECHNOLOGY PLAN
EL121 LIGHTING PLAN
E401 ENLARGED ELECTRICAL PLANS & DIAGRAMS
E501 ELECTRICAL DETAILS
E601 ELECTRICAL SCHEDULES
E602 ELECTRICAL SCHEDULES
T501 TECHNOLOGY DETAILS
SHEET INDEX
SHEET
NO SHEET NAME
G001 PROJECT TITLE SHEET
G002 PROJECT TITLE SHEET
G003 STANDARD MOUNTING HEIGHTS
G004 CODE PLANS & CODE SUMMARY
C000 SITE REMOVALS & EROSION CONTROL PLAN
C001 STORMWATER POLLUTION PREVENTION PLAN (SWPPP) NARRATIVE
C002 STORMWATER POLLUTION PREVENTION PLAN (SWPPP) NARRATIVE
C003 SURFACE WATERS AND PROJECT LOCATION MAP
C100 SITE LAYOUT & SURFACING PLAN
C200 SITE UTILITY PLAN
C300 SITE GRADING PLAN
C400 CONSTRUCTION DETAILS
C401 CONSTRUCTION DETAILS
C402 CONSTRUCTION DETAILS
C403 CONSTRUCTION DETAILS
C404 CONSTRUCTION DETAILS
C405 CONSTRUCTION DETAILS
S000 STRUCTURAL NOTES
S001 STRUCTURAL NOTES, SCHEDULES, & TYPICAL DETAILS
S002 TYPICAL COLD-FORMED STEEL DETAILS
S003 TYPICAL COLD-FORMED STEEL DETAILS
S101 FOUNDATION PLAN
S111 ROOF FRAMING PLAN
S301 STRUCTURAL SECTIONS
S501 FOUNDATION DETAILS
S502 FOUNDATION DETAILS
S511 ROOF FRAMING DETAILS
A101 FLOOR PLAN
A111 ROOF PLAN
A121 REFLECTED CEILING PLAN
A201 EXTERIOR ELEVATIONS
A301 BUILDING SECTIONS
A311 WALL SECTIONS
A411 ENLARGED PLANS & INTERIOR ELEVATIONS
A501 EXTERIOR DETAILS
A511 INTERIOR DETAILS & PARTITION TYPES
A512 INTERIOR DETAILS
A611 DOOR AND WINDOW OPENING SCHEDULES
A711 ROOM FINISH SCHEDULE, FINISH PLANS AND DETAILS
AREA OF WORK
NO DATE REVISION
REFERENCE INDICATORS
ROOM NAME
PLYWOOD
WOOD BLOCKING
MATERIALS
ABBREVIATIONS
PROJECT GENERAL NOTES
ELEVATION INDICATOR
WALL/ PARTITION TYPE.
SEE PARTITION TYPES
FOR ADDITIONAL INFO
DOOR TAG
WINDOW/ LOUVER TAG
INTERIOR ELEVATION REFERENCE
EXTERIOR ELEVATION REFERENCE
BUILDING SECTION REFERENCE
SECTION REFERENCE
REFERENCE TAG
REVISION NUMBER
KEYNOTES
ROOM NAME/ NUMBER101A
DETAIL NUMBER
SHEET NUMBER
G0.01
A5.11
L000
101A.1
A
POINT REFERENCED
ELEVATION
FACE BRICK
CONCRETE BLOCK
CONCRETE BLOCK (LARGE SCALE)
WOOD STUD PARTITION
METAL STUD PARTITION
BATT INSULATION
EXTERIOR RIGID INSULATION
FINISH WOOD
GYPSUM BOARD OR PLASTER
METAL
STONE
EXISTING
A
AB
AC
ACBD
ACT
ADDM
ADJ
ADJ
ADJ
AFF
AHU
ALT
ALUM
AP
APPROX
ARCH
AWT
Absolute Acoustic Acoustic Board Acoustical Ceiling Tile Addendum Adjacent Adjoining Adjustable Above Finished Floor Air Handling Unit Alternate Aluminum Access Panel Approximate Architect Acoustical Wall Treatment
BB
BD
BITUM
BLDG
BLK
BLKG
BM
BMU
BOT
BRG
BUR
Bulletin Board Board Bituminous Building Block Blocking Bench Mark, Beam Burnished Masonry Unit Bottom Bearing Built-Up Roofing
CAB
CB
CI
CJ
CT
CEM
CEMPLAS
CHBD
CG
CL
CLG
CLR
CMU
CO/COR
COL
COMP
CONC
CONF
CONT
CONTR
CPT
CSG
CUH
Cabinet Catch Basin Cast Iron Control Joint Ceramic Tile Cement Cement Plaster Chalk Board Corner Guard Center Line Ceiling Clear Concrete Masonry Unit Contracting Officer (Rep) Column Composition Concrete Conference Continuous Contractor Carpet Casing Cabinet Unit Heater
D
DBL
DEMO
DET
DF
DIA
DIM
DISP
DN
DR
DR
DS
DT
DW
DWG
Depth Double Demolition Detail Drinking Fountain Diameter Dimension Dispenser Down Door Drain Down Spout Drain Tile Dishwasher Drawing
E
EA
EF
EFIS
EJ
EL
ELEC
ELEV
ENCL
EQ
EW
EWC
EXP
EXPMATL
EXT
EXIST
East Each Each Face Exterior Finish Insulation
Expansion Joint Elevation Electrical Elevator Enclosure Equal Each Way Elec.. Water Cooler Expansion, Exposed Expansion Material Exterior Existing
FD
FDTN
FE
FEC
FIN
FLR
FP
FR
FT
FTG
FWC
Floor Drain Foundation Fire Extinguisher Fire Extinguisher Cabinet Finish Floor Fireproofing Frame Foot Footing Fabric Wall Covering
GA
GALV
GB
GEN
GI
GL
GLU LAM
GYP
Gage Galvanized Grab Bar General Galvanized Iron Glass Glued Laminated Wood Gypsum
HC
HD
HDBD
HDW
HDWD
HNDRL
HM
HORIZ
HT
Hollow Core Hand Dryer Hardboard Hardware Hardwood Handrail Hollow Metal Horizontal Height
ID
INSUL
INT
JAN
JST
JT
Inside Diameter Insulation Interior Janitor Joist Joint
LAV
LF
LINO
LKR
LOC
MATL
MAX
MECH
MET/MTL
MEZZ
MFR
MH
MK BD
MIN
MIRR
MISC
MO
MR
MTG
Lavatory Linear Feet (Foot) Linoleum Locker Location, Locate
Material Maximum Mechanical Metal Mezzanine Manufacturer Manhole Marker Board Minimum, Minute Mirror Miscellaneous Masonry Opening Moisture Resistant Mounting
N
NA
NIC
NTS
NO
North Not Applicable Not In Contract Not To Scale Number
OC
OD
OFF
OPNG
OPP
OH
ORIG
On Center Outside Diameter Office Opening Opposite Overhead Original
PC
PBD
PERF
PL
PLAS
PLAM
PLYWD
PREFIN
PTD
PTH
PT
QT
R
RAD
RB
RD
REC
REF
REINF
REQD
RESIL
RM
RO
RS
RTF
S
SAT
SC
SCHED
SECT
SD
SGD
SGT
SHTHG
SIM
SND
SPEC
SQ FT
SS
STL
STOR
STRUCT
SUSP
SV
Portland Cement Particle Board Perforated Plate Plaster Plastic Laminate Plywood Prefinished Paper Towel Dispenser Paper Towel Holder Paint
Quarry Tile
Riser, Radius, Range Radiator Resilient Base Roof Drain Recessed Refrigerator Reinforced Required Resilient Room Rough Opening Rough Sawn Rubber Tile Flooring
South Suspended Acoustical Tile Solid Core Schedule Section Soap Dispenser Sliding Glass Door Structural Glazed Tile Sheathing Similar Sanitary Napkin Dispenser Specification Square Foot Stainless Steel Steel Storage Structural Suspended Sheet Vinyl
T
TB
TD
TEL
TEMP
TER
TKBD
T&G
TPD
TYP
UNEX
UNFIN
UNO
UR
VB
VCT
VERT
VIF
VWC
W W/ W/O
WC
WD
WDW
WGL
WH
WWM
WI
Tread, Toilet Towel Bar Towel Dispenser Telephone Tempered Terrazzo Tack Board Tongue and Groove Toilet Paper Dispenser Typical
Unexcavated Unfinished Unless Noted Otherwise Urinal
Vinyl Base Vinyl Composition Tile Vertical Verify In Field Vinyl Wall Covering
West With Without Water Closet Wood Window Wire Glass Water Heater Welded Wire Mesh Wrought Iron
At Angle Channel Center Line Flow Line Plate Feet Inches Number Smoke Square Round, Diameter
CL
FL
PL
Ø
SYMBOL CHARACTERS
W, X, Y, Z
V
U
T
S
R
Q
PH
I, J, K
L
M
N
O
D
E
F
G
C
B
A3.01
A5.03
CAST-IN-PLACE CONCRETE
System
A. ALL WORK SHALL BE PERFORMED IN STRICT CONFORMANCE WITH LAWS, ORDINANCES,
RULES, CODES AND REGULATIONS OF GOVERNMENT AUTHORITIES HAVING
JURISDICTION.
B. THE GENERAL CONTRACTOR, ASSOCIATED SUBCONTRACTORS, AND ALL OF THEIR
SUBORDINATES (REGARDLESS OF THE TRADE INVOLVED) SHALL FAMILIARIZE
THEMSELVES WITH ALL INFORMATION LOCATED WITHIN THE COMPLETE
CONSTRUCTION DOCUMENT SET (ALL DRAWINGS AND SPECIFICATIONS) PRIOR TO
CONSTRUCTION.
C. CONTRACTOR(S) SHALL MAINTAIN CURRENT RECORD DRAWINGS ON SITE AT ALL TIMES.
D. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR AND ASSOCIATED
SUBCONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN IN THE
CONTRACT DOCUMENTS. THIS INCLUDES REVIEW AND VERIFICATION THAT
DIMENSIONS, LOCATIONS, AND REQUIREMENTS SHOWN ON THESE PLANS ARE
ACCEPTABLE FOR INSTALLATION AND PROPER USE OF THEIR RESPECTIVE SYSTEMS,
MATERIALS AND EQUIPMENT. ANY DEVIATIONS, DISCREPANCIES, AND/OR CONFLICTS
SHALL BE REPORTED IN WRITING TO THE ARCHITECT.
E. PRIOR TO COMMENCEMENT OF ANY OPERATION, EACH CONTRACTOR SHALL EXAMINE
WORK PERFORMED BY OTHERS TO WHICH THEIR WORK ADJOINS OR IS APPLIED, AND
REPORT TO THE ARCHITECT ANY CONDITIONS PREVENTING SATISFACTORY
ACCOMPLISHMENT OF THEIR WORK. STARTING WORK OF ANY OPERATION SHALL
INDICATE ACCEPTANCE OF CONDITIONS.
F. DRAWINGS ARE NOT TO BE SCALED. DIMENSIONS GOVERN, LARGE SCALE DETAILS
GOVERN OVER SMALL SCALE. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND
FIELD CONDITIONS PRIOR TO COMMENCEMENT OF WORK, AND SHALL NOTIFY
ARCHITECT IMMEDIATELY IF ANY CONFLICTS OR DISCREPANCIES OCCUR.
G. MATERIALS AND NOTES COMMON TO SEVERAL DRAWINGS MAY BE NOTED ON ONLY
ONE DRAWING. CONTRACTORS SHALL BE RESPONSIBLE FOR ENTIRE SET OF
DOCUMENTS. REVIEW SPECIFICATIONS FOR INSTRUCTIONS NOT SHOWN ON
DRAWINGS.
H. REFERENCES SHOWN ON DRAWINGS DO NOT NECESSARILY INDICATE ALL LIKE
CONDITIONS AND DO NOT LIMIT APPLICATION OF DRAWING OR DETAIL WHERE SPECIFIC
DIMENSION, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED. CONSULT THE
ARCHITECT PRIOR TO PROCEEDING WITH WORK.
I. CONTRACTOR SHALL ARRANGE TO ACCOMMODATE "NOT IN CONTRACT" WORK. WHEN
INFORMATION IS INADEQUATE, REQUEST FURTHER INSTRUCTIONS BEFORE
PROCEEDING.
J. CONTRACTOR SHALL PERFORM HIGH QUALITY WORK. MATERIALS INSTALLED TO
UNIFORM ACCURATE FIT SO THEY MEET WITH NEAT, STRAIGHT LINES, FREE OF OPEN
SEAMS OR OVERLAPS. INSTALL EXPOSED MATERIALS APPROPRIATELY LEVEL, PLUMB
AND AT ACCURATE RIGHT ANGLES, OR FLUSH WITH ADJOINING MATERIALS. WORK OF
EACH TRADE SHALL MEET OR EXCEED ALL NATIONAL STANDARDS PUBLISHED BY THE
TRADE.
K. COORDINATE WITH ALL SUBCONTRACTORS, ANY REQUIRED OPENINGS, INCLUDING
THOSE NOT INDICATED IN THE CONSTRUCTION DOCUMENT.
L. WHERE ACCESS PANELS ARE REQUIRED FOR EQUIPMENT, UTILITIES, OR DEVICES,
THOSE PANELS SHALL BE INSTALLED WHETHER OR NOT THEY ARE SPECIFICALLY
SHOWN ON THE DRAWINGS. WHEN INSTALLED IN A FIRE RATED ASSEMBLY, THE
ACCESS PANEL MUST BE FIRE RATED TO MATCH THE RATING OF THAT ASSEMBLY.
VERIFY ALL PANEL LOCATIONS WITH ARCHITECT AND OWNER BEFORE INSTALLING.
M. CONTRACTOR SHALL MAINTAIN CLEAN AND PRESENTABLE WORK AND STORAGE
AREAS, AND SHALL NOT ALLOW ANY MATERIAL AS A RESULT OF DEMOLITION OR
CONSTRUCTION TO ACCUMULATE.
N. CONTRACTOR SHALL TAKE CARE TO PROTECT NEWLY INSTALLED MATERIALS.
O. PRIOR TO FINAL INSPECTION OF AND ACCEPTANCE OF THIS PROJECT, THE
CONTRACTOR SHALL HAVE PROJECT AREA FREE FROM ALL CONSTRUCTION DEBRIS,
SCRAPS, MATERIAL, AND EQUIPMENT.
P. UPON COMPLETION OF WORK, CONTRACTOR SHALL REMOVE ALL CONSTRUCTION
DEBRIS. ALL AREAS AFFECTED BY THE PROJECT SHALL BE DELIVERED CLEAN, WHOLE,
TIGHT, AND FIT FOR IMMEDIATE OCCUPANCY.
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
THIS SQUARE APPEARS 1/2"x1/2"
ON FULL SIZE SHEETS
CLIENT:
DULUTH, MINNESOTA
148th FIGHTER WING
MINNESOTA AIR
NATIONAL GUARD
CONSTRUCT SMALL
ARMS RANGE
..\180940 MnANG - Construct Small Arms Range A20.rvt
FMKM179063
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
NO DATE ISSUED FOR
21 W. Superior St., Ste 500 | Duluth, MN 55802 | 218.727.8446
10/5/20 B3 FINAL SUBMITTAL
B
IM
/1
M n A
N G
C o n s tr u c t
S m a ll
A rm s R a n g e
/1
M n
A N
G
C o n s tr u c t S m a ll
A rm s R a n g e
A
.r v t
/2 /2
:5
:4
P
M
G002
10/5/20
CYNTHIA POIRIER
22021
CMK
CIP
180940
PROJECT TITLE SHEET
COMPLY WITH
SIDE WALL GRAB
BAR STANDARDS
STANDARD DRINKING FOUNTAIN
(DF)
ACCESSIBLE DRINKING
FOUNTAIN (ACC DF)
" M
IN
ACCESSIBLE LAVATORY
(ACC LAV)
9" M
IN
" M
IN
" M
IN
" M
A X
TO
R
E
FL
E C
TI
V
E
" M
A X
17" MIN.
8" MIN.
MAX
6"
O
F S
P O
U T
" M
A X
9" M
IN
8" MIN.
O
F S
P O
U T
" M
IN
" M
A X
URINAL (UR)
" M
A X
STANDARD WATER CLOSET (WC)
ACCESSIBLE WATER CLOSET (ACC WC)
" M
A X
12" MIN.
40" MAX.
" M
IN
" M
A X
7"-9" 18 " M
IN
ACCESSORY LOCATION;
ALLOW 1 1/2" MIN.
CLEAR TO GRAB BARS40" MAX.
12" MIN.
" M
A X
S N
D
T P
D
SND/TPD
STANDARD GRAB BARS (GB)
STANDARD GRAB BARS (GB)
6"
12" 42"
54"
39"-41"
VERTICAL GRAB
BAR REQ'D IN MN
12" 24"
6" 36"
42"
SOAP
DISPENSER (SD)
O P
E R
A B
L E P
A R
TS
" M
A X
PAPER TOWEL
DISPENSER (PTD)
O P
E R
A B
L E P
A R
TS
" M
A X
HAND DRYER
(HD)
O P
E R
A B
L E P
A R
TS
" M
A X
FIRE EXTINGUISHER
CABINET (FEC)
TO
C
O N
TR
O
LS
" M
A X
S U
R F
A C
E
6"
" M
IN
LA
T
C H
32"
NURSE CALL (NC),
WHERE OCCURS
ANNUNCIATOR KEY BOX MAILBOXESCOAT / ROBE HOOK
(CH / RH)
TOILET ROOM
SHELF (SH)
MIRROR (MIRR)
" M
A X
" M
A X
" T
Y P
. 60
" M
A X
" M
IN
TO
R
E
FL
E C
TI
V
E
(4 0"
M A
X
A B
O V
E L
A V
T O
C O
N T
R O
LS
O P
E R
A B
LE
P
A R
T S
6" TYP.
12" WIDE (MAX)
6" DEEP (MAX)
M A
X
S U
R F
A C
E
MOP RACK
(MR)
DIVIDER
SCREEN
DIAPER CHANGING
STATION (DCS)
/2
4" MAX.
BARRIER FREE
DOOR ACTUATOR (DA)
" M
IN
" M
A X
FEMININE
HYGIENE
VENDOR (FHV)
O P
E R
A B
L E P
A R
TS
" M
A X
T.
O
. L A
TC
H
" M
A X
STANDARD MOUNTING HEIGHTS
O P
E R
A B
LE
H
G T
W
IT
H N
O
O B
S T
R U
C T
IO
N
S
MOUNTING HEIGHTS FOR EQUIPMENT
PUBLIC RESTROOM FIXTURE / ACCESSORY MOUNTING HEIGHTS (STANDARD ADULT)
LA
TC
H A
P P
R O
A C
H
" M
IN
" M
IN
AMBULATORY STALL
7'
MARKER BOARD (MB)
18" 18"
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
THIS SQUARE APPEARS 1/2"x1/2"
ON FULL SIZE SHEETS
CLIENT:
DULUTH, MINNESOTA
148th FIGHTER WING
MINNESOTA AIR
NATIONAL GUARD
CONSTRUCT SMALL
ARMS RANGE
..\180940 MnANG - Construct Small Arms Range A20.rvt
FMKM179063
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
NO DATE ISSUED FOR
21 W. Superior St., Ste 500 | Duluth, MN 55802 | 218.727.8446
10/5/20 B3 FINAL SUBMITTAL
B
IM
/1
M n A
N G
C o n s tr u c t
S m a ll
A rm s R a n g e
/1
M n
A N
G
C o n s tr u c t S m a ll
A rm s R a n g e
A
.r v t
/2 /2
:5
:4
P
M
G003
10/5/20
CYNTHIA POIRIER
22021
CMK
CIP
180940
STANDARD MOUNTING
HEIGHTS
12' - 0"
20' - 0"
0"
0"
39' - 0"
0"
0"
CODE PLAN LEGEND
= EXIT SIGN
= FIRE EXTINGUISHER / FIRE
EXTINGUISHER CABINET
= EXIT DISTANCE
FE FEC
= BUILDING EXIT/ EXIT ACCESS
XXX sf
OCCUPANT TYPE
ROOM AREA
LOAD FACTORXXXX
XXX OCCUPANT LOAD
= MAX BUILDING DIAGONAL
107' - 0" TRAVEL DISTANCE
68'-0" TRAVEL DISTANCE
RANGE STORAGE
MODULAR ARMS
RANGE
MECH
WEAPONS MAINT &
CLEANING
ELEC
TELE
OPEN OFFICE
9'
3"
X
/3
6'
5"
M
IN
IM
U M
E
XI
T
SE
PA
R
AT
IO
N
BID OPTION: (2) ADDITIONAL SHOOTING LANES
735 SF
CLASSROOM/
BREAKROOM
B 15
WOMEN'S TLT
JANITOR
MEN'S TLT
ALCOVE
110B
558 SF
CIRC
B 150
OTHER
VEST.
3. USE AND OCCUPANCY CLASSIFICATIONS (IBC CHAPTER 3)
A. B BUSINESS - OFFICE AREAS, CLASSROOMS,
SHOOTING SUPPLY STORAGE & MAINTENANCE
5 TYPES OF CONSTRUCTION (IBC CHAPTER 6)
A. TYPE II-B
BUILDING ELEMENT FIRE RESISTANCE
- PRIMARY STRUCTURAL FRAME 0 HR
- EXTERIOR BEARING WALLS 0 HR
- INTERIOR BEARING WALLS 0 HR
- EXTERIOR NON-BEARING WALLS 0 HR
- INTERIOR NON-BEARING WALLS 0 HR
- FLOOR CONST & SECONDARY MEMBERS 0 HR
- ROOF CONST & SECONDARY MEMBERS 0 HR
4. GENERAL BUILDING HEIGHTS AND AREAS (IBC CHAPTER 5)
A. ALLOWABLE BUILDING HEIGHT AND AREAS (TABLE 504)
B OCCUPANCY TYPE II-B 3 STORIES 23,000 SF
B. BUILDING AREA MODIFICATIONS (SECTION 506)
Aa = {At + [At x If] + [At x Is]}
At = 23,000 Aa = {23,000 + [23,000x.75] + [23,000x0]}
ALLOWABLE AREA - 40,250 TOTAL ALLOWABLE
C. FRONTAGE INCREASE (SECTION 506, EQUATION 5-2)
If = [F/P - 0.25]W/30 - [515/515-0.25]30/30 = .75
D. AUTOMATIC SPRINKLER INCREASE (SECTION 506.3)
AREA INCREASE FOR SPRINKLERS NOT TAKEN. BUILDING WILL NOT BE FULLY
SPRINKLED UFC 3-600-01, 9-7.2.1.1 SINGLE STORY LESS THAN 15,000 SF IS
EXEMPT FROM AUTOMATIC SPRINKLER SYSTEM REQUIREMENT.
HOWEVER, ETL 11-18 REQUIRES SPRINKLERS WHEN RANGE IS INTEGRAL WITH
SUPPORT FACILITIES. SPRINKLERS NOT REQUIRED OR DESIRED IN THE DOWN
RANGE OR TARGET AREA OF THE MODULAR RANGE.
6. FIRE AND SMOKE PROTECTION FEATURES (IBC CHAPTER 7)
A. BUILDING ELEMENT FIRE RESISTANCE
FIRE WALLS 3 HR (PER TABLE 706.4)
FIRE BARRIERS 2 HR (PER TABLE 707.3.10)
FIRE PARTITIONS 1 HR (708.3)
- CORRIDOR WALLS 0 HR @ SPRINKLERED CONST
SMOKE BARRIERS 1 HR
SMOKE PARTITIONS 0 HR
7. INTERIOR FINISHES (IBC CHAPTER 8)
A. GROUP B
BUILDING ELEMENT CLASSIFICATION
- EXIT ENCLOSURES AND EXIT PASSAGEWAYS B
- CORRIDORS C
- ROOMS AND ENCLOSED SPACES C
CODE ANALYSIS
9. MEANS OF EGRESS (NFPA 10-1.1)
A. MAX FLOOR AREA PER OCCUPANT (NFPA TABLE 7.3.1.2)
& TABLE 10-1 PER UFC 3-600-01
TOTAL GROSS OCCUPIABLE AREA: 10,053
OFFICE/BUSINESS USE 150 GROSS=10,053-735=9,318/150=63
COLLABORATION ROOM USE 30 NET= 735/15=49 OCCUPANTS
TOTAL OCCUPANTS = 112
B. EXIT CAPACITY (TABLE 7.3.3.1)
.2”/PERSON X 112 PERSONS = 23”
ACTUAL CAPACITY = 2X36”=72”
C. REQUIRED EXITS (7.4.1.1)
(2) EXITS REQUIRED, EXCEPT WHERE (1) IS ALLOWED BY CH. 11-43
DOES NOT MEET EXCEPTIONS FOR ONLY 1 EXIT (OVER 100-PERSON OCCUPANCY)
(7.5.1.3.3) DISTANCES BETWEEN (2) EXITS 1/3 MAX OVERALL DIAGONAL
SPACES WITH ELECTRICAL EQUIPMENT (PER NFPA 70).
(IBC 1008.1.10) ELECT ROOMS WITH RATED EQUIP1,200 AMPS OR MORE AND OVER 6’
WIDE THAT CONTAIN OVERCURRENT DEVICES, SWITCHING DEVICES OR CONTROL
DEVICES, MUST SWING OUT & INCLUDE EXIT DEVICES.
D. COMMON PATH OF EGRESS TRAVEL (NFPA 713.1 (1), 38.2.5.3.1)
COMMON PATH OF EGRESS TRAVEL SHALL NOT EXCEED 100 FEET.
E. EXIT ACCESS TRAVEL DISTANCE (CH. 11-43)
BUSINESS OCCUPANCY = 300’ (38.2.6.3)
F. CORRIDORS: (38.2.5.2.2) DEAD END CORRIDOR SHALL NOT EXCEED 50’.
(38.3.6.1) RATED CORRIDORS NOT REQUIRED IN BUILDING PROTECTED
THROUGHOUT BY AUTOMATIC SPRINKLER SYSTEM
G. MINIMUM NUMBER OF EXITS: (NFPA 7.4) 2 EXITS REQUIRED
ACTUAL NUMBER OF EXITS PROVIDED: 2
10. PLUMBING FIXTURES (IBC CHAPTER 29)
A. (IBC CH. 29, TABLE 2902.1) BUSINESS OCCUPANCY;
REQUIRES 1 WC/25 FOR FIRST 50 OCCUPANTS, THEN 1 /50 REMAINING.
REQUIRES 1 LAV/40 FOR THE FIRST 80 AND 1/80 FOR REMAINING.
REQUIRES 1 DF/100 OCCUPANTS, 1 SERVICE SINK.
116 OCCUPANTS REQUIRES, 4 WC, 3 LAV
4 WC, 2 URINAL, 4 LAV PROVIDED
1. GENERAL INFORMATION
A. PROJECT NAME: CONSTRUCT SMALL ARMS RANGE
B. PROJECT LOCATION: DULUTH IAF, MN
C. GROSS BUILDING SIZE: 9,100 SF
10,053 SF w BID OPTION
F. ACCESSORY OCCUPANCIES (SECTION 508.2)
- AGGREGATE ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE
THAN 10 PERCENT OF THE BUILDING AREA OF THE STORY IN WHICH
THEY ARE LOCATED AND NOT EXCEED TABULAR VALUES IN TABLE 503.
- NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIES
AND THE MAIN OCCUPANCY
G. INCIDENTAL ACCESSORY OCCUPANCIES (TABLE 509)
- FURNACE ROOMS (over 400,000 BTU) 1 HR OR SPRINKLER SYSTEM
- BOILER ROOMS (over 15 PSI and 10 HP) 1 HR OR SPRINKLER SYSTEM
2. APPLICABLE CODES
A. MINNESOTA STATE BUILDING CODE 2015 EDITION
B. INT'L BUILDING CODE (W/ AMENDMENTS) 2012 EDITION
C. INT'L FIRE CODE (W/ AMENDMENTS) 2012 EDITION
D. MINNESOTA MECHANICAL AND FUEL GAS CODE 2015 EDITION
E. MINNESOTA PLUMBING CODE 2015 EDITION
F. NATIONAL ELECTRICAL CODE (NEC) 2017 EDITION
G. MINNESOTA COMMERCIAL ENERGY CODE 2012 EDITION
H. MINNESOTA ACCESSIBILITY CODE 2015 EDITION
I. ANG DESIGN POLICY, ETL 15-01, 1 MAY 2015
J. NFPA 101 2018 EDITION
K. 2017 NFPA 70 NATIONAL ELECTRICAL CODE
L. 2010 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE
M. UFC 1-200-01, DOD GENERAL BUILDING REQUIREMENTS.
N. UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES
8. FIRE PROTECTION SYSTEMS (UFC 3-600-01, ELT 02-15,
FOLLOW NFPA 409 PER IBC)
A. BUILDING NOT SPRINKLERED
B. FIRE EXTINGUISHERS ARE NOT REQUIRED (UFC 3-600-01, 9-17.1)
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
THIS SQUARE APPEARS 1/2"x1/2"
ON FULL SIZE SHEETS
CLIENT:
DULUTH, MINNESOTA
148th FIGHTER WING
MINNESOTA AIR
NATIONAL GUARD
CONSTRUCT SMALL
ARMS RANGE
..\180940 MnANG - Construct Small Arms Range A20.rvt
FMKM179063
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
NO DATE ISSUED FOR
21 W. Superior St., Ste 500 | Duluth, MN 55802 | 218.727.8446
10/5/20 B3 FINAL SUBMITTAL
B
IM
/1
M n A
N G
C o n s tr u c t
S m a ll
A rm s R a n g e
/1
M n
A N
G
C o n s tr u c t S m a ll
A rm s R a n g e
A
.r v t
/2 /2
:5
:4
P
M
G004
10/5/20
CYNTHIA POIRIER
22021
CMK
CIP
180940
CODE PLANS & CODE
SUMMARY
1/8" = 1'-0"1
CODE PLAN
CONSTRUCT SMALL
ARMS RANGE
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C000 (DEMO).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C000
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
SITE REMOVALS &
EROSION CONTROL PLAN
PAB
DRP
WARNING
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C000 (DEMO).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C001
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
STORMWATER POLLUTION
PREVENTION PLAN (SWPPP)
NARRATIVE
PAB
STORM WATER POLLUTION PREVENTION PLAN (SWPPP) NARRATIVE
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C000 (DEMO).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C002
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
STORMWATER POLLUTION
PREVENTION PLAN (SWPPP)
NARRATIVE
PAB
STORM WATER POLLUTION PREVENTION PLAN (SWPPP) NARRATIVE
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C000 (DEMO).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C003
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
SURFACE WATERS AND
PROJECT LOCATION MAP
PAB
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C100 (SURF).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C100
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
SITE LAYOUT &
SURFACING PLAN
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C200 (UTIL).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C200
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
SITE UTILITY PLAN
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C300 (GRAD).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C300
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
SITE GRADING PLAN
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C400 (DETL).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C400
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
CONSTRUCTION DETAILS
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C400 (DETL).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C401
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
CONSTRUCTION DETAILS
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C400 (DETL).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C402
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
CONSTRUCTION DETAILS
SIGN SCHEDULE
ARMS RANGE
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C400 (DETL).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C403
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
CONSTRUCTION DETAILS
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C400 (DETL).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C404
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
CONSTRUCTION DETAILS
NO DATE REVISION
DRAWING TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
FILE:
DRAWING NO:
PROJ. NO:
..\180940\600 Drawings\C\180940_C400 (DETL).dwg
21 W. Superior St., Ste. 500 | Duluth, MN 55802 | 218.727.8446
COPYRIGHT 2020 BY LHB, INC. ALL RIGHTS RESERVED.
C405
180940
MINNESOTA AIR
148TH FIGHTER WING
CLIENT:
NO DATE ISSUED FOR
THIS SQUARE APPEARS 1/2" x 1/2" ON
FULL SIZE SHEETS.
NATIONAL GUARD
FMKM 179063
1 10/5/20 TYPE B3 FINAL SUBMITTAL
CONSTRUCTION DETAILS
GENERAL DESIGN AND CONSTRUCTION NOTES
A. BUILDING CODE
1. 2015 MINNESOTA STATE BUILDING CODE (MSBC).
2. 2012 INTERNATIONAL BUILDING CODE (IBC).
3. ANG ETL 15-01, 1 MAY 2015
4. UFC 3-301-01, 1 OCTOBER 2019, STRUCTURAL ENGINEERING.
5. UFC 4-010-01, 12 DECEMBER 2018, DoD MINIMUM ANTITERRORISM STANDARDS
FOR BUILDINGS.
B. DESIGN LOADS
1. FLOOR LIVE LOAD: UNIFORM (PSF) CONCENTRATED (LB)
OFFICES: . . . . . . . . . . . . . . . . . . . 50 2,000
FIRST FLOOR CORRIDORS: . . . 100 2,000
LIGHT STORAGE: . . . . . . . . . . . . 125 0
MECHANICAL: . . . . . . . . . . . . . . . 100 ACTUAL
LIVE LOAD REDUCTION WAS NOT UTILIZED IN THE DESIGN.
2. ROOF LIVE LOAD: 20 PSF
3. ROOF SNOW LOAD: 60 PSF GROUND SNOW PLUS SNOW ACCUMULATION
PER IBC AND ASCE 7.
a. FLAT ROOF SNOW LOAD, Pf = 42 PSF
b. SNOW EXPOSURE FACTOR, Ce = 1.0
c. SNOW IMPORTANCE FACTOR, I = 1.0
d. THERMAL FACTOR, Ct = 1.0
4. WIND LOAD: ULTIMATE DESIGN WIND SPEED, Vult = 115 MPH (3 SEC GUST) NOMINAL DESIGN WIND SPEED, Vasd = 89.1 MPH
RISK CATAGORY = II
WIND EXPOSURE = C
INTERNAL PRESSURE COEFFICIENT = +/- 0.18
COMPONENTS AND CLADDING WIND PRESSURES
TRIBUTARY AREA 0-10 FT² 10-50 FT² >50 FT²
ROOF NEGATIVE:
ZONE 1: 31.6 PSF 29.7 PSF 28.9 PSF
ZONE 2: 53.1 PSF 39.9 PSF 34.3 PSF
ZONE 3: 79.8 PSF 48.0 PSF 34.3 PSF
ROOF POSITIVE:
ZONES 1, 2, & 3: 16.0 PSF 16.0 PSF 16.0 PSF
TRIBUTARY AREA 0-10 FT² 10-100 FT² >100 FT²
WALL NEGATIVE:
ZONE 4: 31.3 PSF 27.1 PSF 24.1 PSF
ZONE 5: 38.6 PSF 30.1 PSF 24.1 PSF
WALL POSITIVE:
ZONES 4 & 5: 28.9 PSF 24.7 PSF 21.7 PSF
a. REFER TO WIND PRESSURE DIAGRAM FOR ZONES.
b. DIMENSION "a" = 5.9 FT.
5. EARTHQUAKE DESIGN DATA:
a. SEISMIC IMPORTANCE FACTOR , I: 1.0
b. OCCUPANCY CATEGORY: II
c. MAPPED SPECTRAL RESPONSE ACCELERATIONS, SS = 0.041 AND S1 = 0.017
d. SITE CLASS: D (ASSUMED)
e. SPECTRAL RESPONSE COEFFICIENTS, SDS = 0.044 AND SD1 = 0.027
f. SEISMIC DESIGN CATEGORY = A
g. BASIC SEISMIC-FORCE-RESISTING SYSTEM(S): ORDINARY REINFORCED
MASONRY SHEAR WALLS
h. DESIGN BASE SHEAR: V = 0.022W
i. SEISMIC RESPONSE COEFFICIENT(S), CS = 0.022
j. RESPONSE MODIFICATION FACTOR(S), R = 2.0
k. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE ANALYSIS
6. LOADS PROVIDED ON DRAWINGS ARE UNFACTORED ALLOWABLE STRESS
DESIGN LOADS. 1.33 ALLOWABLE STRESS INCREASE FOR SHORT-TERM
LOADING IS NOT ALLOWED.
7. BLAST LOADS: IN ACCORDANCE WITH DoD MINIMUM ANTITERRORISM
STANDARDS FOR BUILDINGS, UFC 4-010-01.
8. SOIL LOADS: ALL WALLS LATERALLY SUPPORTING SOIL SHALL BE DESIGNED
FOR THE AT-REST EQUIVALENT FLUID EARTH PRESSURE OF 60 pcf AT WALL /
SOIL INTERFACE.
WALLS
a a a a
WIND PRESSURE DIAGRAMS
MONOSLOPE ROOFS
3° < 0 ≤ 10° a a a a
3 2 3
2 1 2
3 2 3
GENERAL CONSTRUCTION NOTES
A. FOOTINGS AND FOUNDATION
1. SOIL DESIGN NET ALLOWABLE BEARING CAPACITY IS 3000 PSF IN ACCORDANCE
WITH THE GEOTECHNICAL REPORT DATED JANUARY 14, 2019 BY BRAUN
INTERTEC CORPORATION. NOTIFY ENGINEER OF RECORD OF ANY POOR SOIL
CONDITIONS ENCOUNTERED.
2. MINIMUM DEPTH FROM EXTERIOR GRADE TO BOTTOM OF BUILDING PERIMETER
FOOTINGS SHALL BE 60". ALL OPEN AIR FOUNDATIONS SHALL HAVE A MINIMUM
OF 72" OF FROST PROTECTION.
3. BOTH SIDES OF FOUNDATION WALLS SHALL BE BACKFILLED SIMULTANEOUSLY
SO AS TO PREVENT OVERTURNING OR LATERAL MOVEMENT OF WALLS.
BACKFILLING OF BASEMENT WALLS SHALL NOT COMMENCE UNTIL FLOOR
SYSTEMS TOP AND BOTTOM ARE IN PLACE, CURED 7 DAYS, AND ALL NECESSARY
BRACING HAS BEEN INSTALLED.
4. FOUNDATIONS SHALL BEAR ON UNDISTURBED, UNFROZEN SUBGRADE, EXCEPT
WHERE COMPACTED SUBGRADE OR FILL IS OTHERWISE SPECIFIED, OR
FOUNDATIONS BEAR ON ROCK.
5. PROVIDE STANDARD 90 DEGREE HOOK DOWELS BETWEEN FOUNDATIONS AND
WALLS EQUAL TO THE SIZE AND SPACING OF THE VERTICAL REINFORCING
UNLESS SPECIFICALLY NOTED OTHERWISE.
6. RIGID INSULATION SHALL BE EXTRUDED POLYSTYRENE MEETING ASTM C578-08,
TYPE IV, 25 PSI MINIMUM COMPRESSIVE RESISTANCE, MANUFACTURED FOR USE
BELOW GRADE. PLACE ALL RIGID INSULATION IN TWO EQUAL THICKNESS LAYERS
AND STAGGER JOINTS.
7. SEE CIVIL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ALL UNDERSLAB
UTILITIES, WATER MAINS, ETC.
B. FILL NOTES
1. MATERIALS:
a. GENERAL FILL: NON-ORGANIC SELECT COMPACTABLE SUBSOIL
EXCAVATED ON SITE AND/OR MNDOT 2105.2B2 COMMON BORROW.
WHEN ON-SITE GENERAL FILLS ARE EXHAUSTED OR FOUND TO BE
UNSUITABLE FOR USE DUE TO MOISTURE CONTENT, ORGANICS, OR
OVERSIZED ROCK, THE CONTRACTOR SHALL PROVIDE MnDOT COMMON
BORROW AS NECESSARY TO COMPLETE THE WORK AT NO ADDITIONAL
COST TO THE OWNER. MATERIAL MUST BE GRADED, FREE OF LUMPS
LARGER THAN 3 INCHES, ROCKS LARGER THAN 2 INCHES, AND DEBRIS.
MOISTURE CONTENT OF SALVAGED SOILS SHALL BE MANAGED BY THE
CONTRACTOR.
b. STRUCTURAL FILL (NFS) ALLOWABLE SOIL TYPES: SP, SP-SM, SM.
100 PERCENT PASSING THE 2-INCH SIEVE. LESS THAN 2 PERCENT
ORGANIC CONTENT.
c. SAND: CONFORMING TO MnDOT 3149.2K SAND COVER MODIFIED SO THAT
NOT MORE THAN 5% PASSES THE NO. 200 SIEVE.
2. PLACE AND COMPACT MATERIALS IN EQUAL CONTINUOUS LAYERS NOT
EXCEEDING 12 INCHES COMPACTED DEPTH.
3. COMPACTED FILL SHALL MEET THE FOLLOWING MINIMUM STANDARD PROCTOR
TEST VALUES (ASTM D698) AND SHALL BE TESTED BY A QUALIFIED
GEOTECHNICAL AGENCY AS FOLLOWS:
a. SLABS-ON-GRADE: ONE TEST FOR EVERY 1000 SQ. FT. PER 1 FT. OF DEPTH
OR FRACTION THEREOF TO 95% OF MAXIMUM DRY DENSITY.
b. FOUNDATION WALLS AND FOOTINGS: ONE TEST FOR EVERY 25 LIN. FT. OF
WALL / FOOTING LENGTH AND ONE TEST UNDER EACH COLUMN FOOTING
TO 95% OF MAXIMUM DRY DENSITY.
4. FILL AT SPECIFIC LOCATIONS:
a. USE GENERAL FILL UNLESS OTHERWISE SPECIFIED.
b. UNDER FOOTINGS: USE STRUCTURAL FILL.
c. UNDER INTERIOR SLABS-ON-GRADE: USE GRANULAR FILL UP TO
SUBGRADE, THEN STRUCTURAL FILL AS SPECIFIED ON THE DRAWINGS.
3. TESTING REQUIREMENTS:
a. CONCRETE:
I) COMPRESSIVE STRENGTH - ASTM C39, (3) 4x8 CYLINDERS FOR EACH
TYPE OF CONCRETE FOR EVERY 50 YARDS EACH DAY.
II) ONE SLUMP TEST FOR EACH TRUCK.
iii) ONE AIR TEST FOR EACH TRUCK.
b. MASONRY:
i) VERIFY PERIODIC PLACEMENT OF REINFORCEMENT AND GROUTING
TECHNIQUE.
ii) GROUT MIXES PER ASTM C1019, SAME FREQUENCY AS PRISM TESTS.
c. FIELD BOLTING & WELDING:
i) VISUAL INSPECTION OF ALL FIELD WELDS & BOLTS SHALL BE
PERFORMED.
d. BACKFILL:
i) VERIFY SOIL REMOVAL.
ii) TEST SOIL COMPACTION - ONE TEST FOR EVERY 3000 SQUARE FEET.
e. CONTRACTOR TO PROVIDE AND PAY FOR ALL TESTING BY AN OWNER APPROVED
TESTING FIRM. TESTING REPORTS SHALL BE SUBMITTED TO OWNER ON A WEEKLY
BASIS.
E. USE OF DRAWINGS
1. DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC
DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE
ON THE PROJECT.
2. WHERE DISCREPANCIES OCCUR WITHIN THE CONTRACT DOCUMENTS, THE MOST COSTLY
REQUIREMENT IS TO BE MET.
C. CONSTRUCTION NOTES
1. ALL DIMENSIONS INVOLVING COORDINATION OF NEW WORK WITH EXISTING
CONSTRUCTION SHALL BE FIELD-CHECKED BY THE CONTRACTOR AND FURNISHED
TO THE SUBCONTRACTORS PRIOR TO FABRICATION OF ANY WORK. THE VERIFIED
DIMENSIONS SHALL APPEAR AND BE NOTED ON THE SHOP DRAWINGS SUBMITTED.
2. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING BUILDINGS,
UTILITIES, STREETS, ETC. DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE
FOR DESIGN AND INSTALLATION OF ALL NECESSARY TEMPORARY BRACING.
3. ANY HOLES CUT IN NEW OR EXISTING CONSTRUCTION THAT ARE NOT DETAILED ON
THE STRUCTURAL DRAWINGS SHALL BE REVIEWED WITH THE STRUCTURAL
ENGINEER. COORDINATE ALL HOLES AND PENETRATIONS WITH OTHER DISCIPLINES.
4. THE STRUCTURE SHALL BE ADEQUATELY BRACED AND SHORED DURING
CONSTRUCTION AGAINST WIND, ERECTION AND OTHER LOADS. STRUCTURAL
MEMBERS ARE DESIGNED FOR IN-PLACE LOADS BASED ON FINAL SUPPORT
CONDITIONS.
5. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF DISCREPANCIES
FOUND BETWEEN CONSTRUCTION DOCUMENTS AND ACTUAL FIELD CONDITIONS.
D. QUALITY ASSURANCE AND CONTROL
1. SEE PROJECT "SPECIAL STRUCTURAL TESTING AND INSPECTION SUMMARY
SCHEDULE".
2. SUBMITTALS:
a. CONCRETE MIX DESIGN FOR EACH TYPE OF CONCRETE.
b. PRODUCT DATA FOR CONCRETE ADMIXTURES.
c. SHOP DRAWINGS FOR CONCRETE REINFORCING.
d. SHOP DRAWINGS FOR STRUCTURAL STEEL.
e. WELDER CERTIFICATION.
f. SHOP DRAWINGS FOR STEEL JOISTS & METAL DECK.
g. MORTAR & GROUT MIX DESIGNS.
9. SEE "MINIMUM LAP SPLICES OF REINFORCING BARS IN TENSION" CHART FOR LAP
SPLICE LENGTHS.
10. COORDINATE GROUNDING REQUIREMENTS BETWEEN FOUNDATION
CONSTRUCTION AND ELECTRICAL WORK.
11. PROVIDE EXTRA REINFORCING ON EACH FACE AROUND ALL OPENINGS 24" OR
LARGER IN ALL SLABS & WALLS EQUAL TO (2) #5 BARS ON ALL FOUR SIDES AND
EXTEND 2 FEET BEYOND OPENINGS.
12. PROVIDE ISOLATION JOINTS AROUND COLUMNS AT SLAB ON GRADE. SEE
DETAIL 1/S502.
13. SEE 1/S501 FOR TYPICAL SLAB ISOLATION JOINT TO BE PROVIDED AT ALL
LOCATIONS UNLESS NOTED OTHERWISE.
14. SEE 7/S501 FOR TYPICAL SLEEVED OPENINGS IN CONCRETE FOUNDATION
WALLS.
15. CONSOLIDATE ALL CONCRETE, INCLUDING SLABS, BY VIBRATING.
16. MIX DESIGNS SHALL INCORPORATE ADMIXTURES AS APPROPRIATE FOR
ENVIRONMENTAL CONDITIONS.
17. ALL REINFORCING SHALL BE DETAILED, FABRICATED & PLACED IN ACCORDANCE
WITH ACI SP-66 (04), ACI DETAILING MANUAL - 2004, AND CRSI MANUAL OF
STANDARD PRACTICE.
18. COMPLETE SAWING OF ALL CONTROL JOINTS WITHIN 12 HOURS OF PLACEMENT.
CONSTRUCTION AND CONTROL JOINTS SHALL BE AS INDICATED ON THE
DRAWINGS.
19. SPACING OF CONSTRUCTION OR CONTROL JOINTS IN WALLS EXPOSED TO VIEW
SHALL NOT EXCEED 20 FEET UNLESS SPECIFICALLY NOTED OTHERWISE ON THE
DRAWINGS. DISCONTINUE OR CUT HALF OF THE HORIZONTAL REINFORCING AT
CONTROL JOINTS.
B. CONCRETE NOTES
1. PERFORM WORK IN ACCORDANCE WITH ACI 301-14 AND ACI 318-14.
2. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR
REINFORCEMENT:
MINIMUM
COVER (IN.)
CONCRETE CAST AGAINST &
PERMANENTLY EXPOSED TO EARTH:
CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 THRU #11 BARS:
#5 & SMALLER BARS: . . . . . . . . . . . . . . . . . . . . . . 1 1/2
CONCRETE NOT EXPOSED TO WEATHER
OR IN CONTACT WITH GROUND:
SLABS AND WALLS: . . . . . . . . . . . . . . . . . . . . . . . 3/4
BEAMS AND COLUMNS: . . . . . . . . . . . . . . . . . . . . 1 1/2
3. PROVIDE A 3/4" CHAMFER ON ALL EXPOSED CONCRETE CORNERS.
4. PROVIDE LAP SPLICES AT ALL CORNERS AND INTERSECTIONS, SAME SIZE AND
SPACING AS HORIZONTAL REINFORCING.
5. ALL HORIZONTAL WALL REINFORCING SHALL RUN CONTINUOUS THROUGH PIERS.
6. PROVIDE SUPPORTS AND SPACERS FOR ALL REINFORCING, INCLUDING WWF.
7. SEE ARCHITECTURAL PLANS FOR DEPRESSED AND SLOPED AREAS IN FLOORS NOT
SHOWN ON STRUCTURAL DRAWINGS.
8. ALL CONCRETE SHOWN SHALL BE REINFORCED. PLANS, SECTIONS AND DETAILS
SHOWN WITHOUT REINFORCEMENT ARE INTENDED TO SHOW DIMENSIONS AND
DETAILS OF CONSTRUCTION ONLY. REINFORCEMENT OF THESE SECTIONS SHALL BE
PROVIDED IN ACCORDANCE WITH THE DETAILS SHOWING REINFORCEMENT.
CAST-IN-PLACE CONCRETE
A. MATERIAL PROPERTIES
1. CONCRETE PROPERTIES: MAX.
fc (PSI) EXPOSURE SLUMP MAX ENTR MAX.
28 DAYS CLASS INCHES AGGR. AIR (%) W/C
FOOTINGS:. . . . . . . . . . . . . . . . . . 4,000 F0 4 1 1/2" 0 -
WALLS, GRADE BEAMS, PIERS:. 4,500 F2 4 3/4" 0* 0.45
INT. SLAB ON GRADE (NW):. . . . 4,000 F0 4 3/4" 0 0.50
STOOPS, APRONS:. . . . . . . . . . . 5,000 F3 4 3/4" 6 ± 1.5 0.40
* USE 6%±1.5% ENTRAINED AIR IF EXTERIOR CONCRETE.
2. REINFORCING PROPERTIES: FY (PSI) ASTM
ALL BARS UNLESS NOTED OTHERWISE: . . . . . . . . . 60,000 A615
TIES & STIRRUPS: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60,000 A615
WELDED WIRE FABRIC (SMOOTH, SHEETS):. . . . . . . 65,000 A185
WELDABLE REINFORCEMENT: . . . . . . . . . . . . . . . . . . 60,000 A706
EPOXY COATING:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A A775
3. CHAIRS AND BOLSTERS SHALL BE PLASTIC OR EPOXY COATED.
4. IF CONCRETE SUPPORT BLOCKS ARE USED, THEIR STRENGTH SHALL BE EQUAL OR GREATER
THAN THAT OF THE CONCRETE BEING PLACED.
5. WATERSTOP: POLYVINYL CHLORIDE, MINIMUM 1750 PSI TENSILE
STRENGTH, MINIMUM 50 DEGREES F TO PLUS 175 DEGREES F WORKING
TEMPERATURE RANGE, 6 INCH WIDE, MAXIMUM POSSIBLE LENGTHS,
RIBBED PROFILE, PREFORMED CORNER SECTIONS, HEAT WELDED
JOINTING.
6. THE FOLLOWING MATERIALS SHALL NOT EXCEED THE FOLLOWING
PERCENT OF TOTAL CEMENTITIOUS MATERIAL BY WEIGHT:
FLY ASH: . . . . . . . . . . . . . . . . . . . . .15% SLABS, 25% ELSEWHERE
GROUND GRANULATED
BLAST FURNACE SLAG: . . . . . . . . 15% IN SLABS, 50% ELSEWHERE
FLY ASH AND SLAG COMBINED: 15% IN SLABS, 50% ELSEWHERE
SOLUBLE CHLORIDE: . . . . . . . . . . 0.1%
7. CONCRETE COMPONENTS SHALL MEET THE FOLLOWING ASTM:
PORTLAND CEMENT: . . . . . . . . . . . . . . . . . . . . C150, TYPE I OR III
FINE AND COARSE AGGREGATES: . . . . . . . . . . . . . . . . . . . . . C33
FLYASH: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C618, CLASS C OR F
GROUND GRANULATED BLAST
FURNACE SLAG . . . . . . . . .ASTM C989, GRADE 100 OR 120
AIR ENTRAINING ADMIXTURES: . . . . . . . . . . . . . . . . . . . . . . . C260
OTHER CHEMICAL ADMIXTURES: . . . . . . . . . . . . C494, TYPE A-G
WATER, CLEAN & NOT DETRIMENTAL TO CONCRETE: . . . C1602
MASONRY
A. MATERIAL PROPERTIES: STRENGTH (PSI) ASTM
HOLLOW MASONRY UNITS (INDIVIDUAL): . . . . . . . 1,900 C90-N
HOLLOW MASONRY UNITS (AVERAGE NET) f'm: . 1,500
MORTAR TYPE S (ABOVE GRADE): . . . . . . . . . . . . 1,800 C270
MORTAR TYPE M (BELOW GRADE): . . . . . . . . . . . . 2,500 C270
GROUT (COREFILL): . . . . . . . . . . . . . . . . . . . . . . . . . 3,000 C476
REINFORCING BARS: . . . . . . . . . . . . . . . . . . . . . . . . 60,000 A615
COLD DRAWN STEEL WIRE: . . . . . . . . . . . . . . . . . . 70,000 A1064, GALV.
B. MASONRY NOTES
1. DESIGN AND CONSTRUCTION SHALL COMPLY WITH TMS 402/602-16.
2. ALL REINFORCEMENT SPLICES SHALL BE 48 BAR DIAMETERS UNLESS NOTED
OTHERWISE.
3. ALL MASONRY WALLS SHALL HAVE A MINIMUM OF (1) #5 AT 32" ON CENTER (MAX.)
SPACING UNLESS NOTED OTHERWISE. PROVIDE (2) #5 BARS FULL HEIGHT AT EACH
SIDE OF MASONRY OPENINGS WIDER THAN 4'-0" AND AT CORNERS UNLESS NOTED
OTHERWISE.
4. BOND BEAMS SHALL BE CONTINUOUS AND REINFORCED WITH (2) #5 BARS OR AS
NOTED. DISCONTINUE BARS AT CONTROL JOINTS UNLESS NOTED OTHERWISE.
5. MASONRY WALLS WITH EARTH ON BOTH SIDES SHALL HAVE ALL CELLS FILLED SOLID
WITH GROUT.
6. CONSOLIDATE GROUT POURS 12" OR LESS IN HEIGHT BY MECHANICAL. CONSOLIDATE
POURS EXCEEDING 12" IN HEIGHT BY MECHANICAL VIBRATION AND RECONSOLIDATE BY
MECHANICAL VIBRATION AFTER INITIAL WATER LOSS AND SETTLEMENT HAS OCCURED.
7. WHEN GROUT IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL CONSTRUCTION
JOINTS SHALL BE FORMED BY STOPPING THE GROUT POUR 1-1/2" BELOW THE TOP OF
THE UPPERMOST UNIT. IF THE UPPERMOST UNIT IS A BOND BEAM, STOP POUR 1/2"
BELOW THE TOP OF MASONRY.
8. FIELD WELD BOND BEAM REINFORCING TO STEEL COLUMNS, BEAMS AND LINTELS
WHERE BOND BEAM REINFORCING IS INTERRUPTED.
9. ALL CMU WALLS SHALL BE BUILT INTEGRALLY AND PROVIDED WITH A CONTINUOUS
BOND BEAM AT THE TOP OF THE WALL AND AT LOCATIONS AS INDICATED.
10. PROVIDE FULL-DEPTH BOND BREAK MATERIAL BETWEEN STRUCTURAL AND NON-
STRUCTURAL MASONRY WALLS WHERE THEY INTERSECT.
11. NON-STRUCTURAL PARTITION WALLS SHALL BE LATERALLY SUPPORTED AT THE TOP
PER DETAIL 6/S511.
12. MASONRY WALLS SHALL HAVE CONTROL JOINTS AT A MAXIMUM SPACING OF 25 FEET
UNLESS NOTED OTHERWISE. IF CONTROL JOINTS ARE NOT SPECIFICALLY SHOWN ON
THE DRAWINGS, CONTRACTOR SHALL FOLLOW LOCALLY ACCEPTED PRACTICES.
CONTROL JOINTS SHALL BE PLACED AT ABRUPT CHANGES IN WALL HEIGHT OR
THICKNESS, ABOVE JOINTS IN FOUNDATION OR SUPPORTING FLOOR SLABS, WITHIN 12
FEET OF ALL CORNERS AND AT ONE OR BOTH SIDES OF DOOR AND WINDOW OPENING,
DEPENDING ON THE WIDTH AND LOCATION OF THE OPENING.
13. GROUT LIFTS SHALL NOT EXCEED 5 FEET WITHOUT APPROVAL OF THE ENGINEER.
14. SECURE VERTICAL REINFORCING IN REQUIRED ALIGNMENT BEFORE GROUTING.
15. PROVIDE 9-GAUGE (.148 INCH), HOT-DIP GALVANIZED TRUSS-TYPE HORIZONTAL JOINT
REINFORCEMENT MEETING THE REQUIREMENTS OF ASTM A1064 / A1064M AND ASTM
A153 / A153M (DUR-O-WALL OR EQUAL) EVERY COURSE IN STACK BOND WALLS AND
EVERY OTHER COURSE IN RUNNING BOND WALLS. WALLS SHALL BE RUNNING BOND
UNLESS NOTED OTHERWISE.
16. SUBMIT SHOP DRAWINGS CLEARLY SHOWING REINFORCEMENT LAYOUT,SIZE, SPACING
AND DETAILS TO ARCHITECT/ENGINEER FOR REVIEW.
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
CONSTRUCT SMALL
ARMS RANGE
XXX
COPYRIGHT 2019 BY LHB, INC. ALL RIGHTS RESERVED.
21 W. Superior St., Ste 500 | Duluth, MN 55802 | 218.727.8446
THIS SQUARE APPEARS 1/2"x1/2"
ON FULL SIZE SHEETS
CLIENT:
148th FIGHTER WING
MINNESOTA AIR
NATIONAL GUARD
NO DATE ISSUED FOR
NO DATE REVISION
DULUTH, MINNESOTA
FMKM179063
10/05/20 B3 FINAL SUBMITTAL1
B
IM
/1
M n A
N G
C o n s tr u c t
S m a ll
A rm s R a n g e
/1
M n
A N
G
C o n s tr u c t S m a ll
A rm s R a n g e
S
.r v t
/6 /2
:2
:4
P
M
S000
JENNIFER M. BABCOCK
4076810/05/20
MAS
JMB
180940
STRUCTURAL NOTES
STRUCTURAL STEEL
A. MATERIAL PROPERTIES
1. STEEL PROPERTIES: Fy (PSI) Fu (PSI) ASTM
W SHAPES: . . . . . . . . . . . . . . . . . . . 50,000 65,000 A992, A572
OTHER SHAPES, PLATES: . . . . . . . 36,000 58,000 A36
HOLLOW STRUCTURAL SECTIONS: 50,000 62,000 A500, GR C
STEEL PIPES: . . . . . . . . . . . . . . . . . 35,000 60,000 A53, GR B
HIGH STRENGTH BOLTS, U.N.O.,
BEARING CONNECTIONS: . . . . . . 92,000 120,000 F3125 (A325N)
HIGH STRENGTH BOLTS, SLIP
CRITICAL CONNECTIONS,
(WHERE NOTED): . . . . . . . . . . . . . 92,000 120,000 F3125 (A325 SC CLASS A)
NUTS: . . . . . . . . . . . . . . . . . . . . . . . . . - - A563 HEAVY HEX*
WASHERS: . . . . . . . . . . . . . . . . . . . . . - - F436 HARDENED STL
ANCHOR RODS: . . . . . . . . . . . . . . . . 36,000 58,000 F1554 GR 36
WELDING ELECTRODES: . . . . . . . . - E70XX A233
* GRADE DH WHEN GALVANIZED
2. GROUT: NON-SHRINK, NON-METALLIC AGGREGATE TYPE, COMPLYING WITH ASTM C1107
AND CAPABLE OF DEVELOPING A MINIMUM COMPRESSIVE STRENGTH OF 7,000 PSI AT 28
DAYS.
B. STRUCTURAL STEEL NOTES
1. STRUCTURAL STEEL DESIGN AND CONSTRUCTION SHALL CONFORM TO AISC STEEL
CONSTRUCTION MANUAL & SPECIFICATIONS (AISC 360-16), FOURTEENTH EDITION.
2. THE CONTRACTOR AND FABRICATOR SHALL REVIEW THE CONTRACT DOCUMENTS AND
INCORPORATE ANY ADDITIONAL PROVISIONS NECESSARY TO MEET APPLICABLE
SAFETY REGULATIONS.
3. CAMBERS SHOWN REFLECT THE IN-PLACE ERECTED, BEAM DEAD LOAD CONDITION.
CAMBERS SHALL BE INCREASED ACCORDINGLY BY STRUCTURAL STEEL SUPPLIER TO
ACCOUNT FOR LOSS OF CAMBER DUE TO CAMBERING PROCESS. SINGLE POINT
CAMBERING WILL ONLY BE PERMITTED IF APPROVED IN WRITING BY STRUCTURAL
ENGINEER.
4. THIS STRUCTURE IS A NON-SELF SUPPORTING STEEL FRAME REQUIRING INTERACTION
WITH OTHER ELEMENTS TO PROVIDE THE REQUIRED STABILITY. THE STEEL ERECTOR
SHALL PROVIDE TEMPORARY SUPPORTS UNTIL FINAL STABILITY IS PROVIDED. AT A
MINIMUM, TEMPORARY SUPPORTS SHALL BE PROVIDED AT EACH GRID IN BOTH
DIRECTIONS.
5. PROVIDE ASPHALTIC COATING AROUND STRUCTURAL STEEL BELOW GRADE.
6. ALL SHOP CONNECTIONS SHALL BE WELDED AND FIELD CONNECTIONS BOLTED
UNLESS NOTED OTHERWISE. ALL WELDING SHALL BE BY AN AWS CERTIFIED WELDER.
7. UNLESS NOTED OTHERWISE, CONNECTIONS SHALL BE DESIGNED BY THE FABRICATOR.
ALL DETAILING SHALL CONFORM TO AISC AND OSHA ERECTION STANDARDS.
COMPLIANCE IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
8. CONNECTIONS SHALL BE DESIGNED AS FOLLOWS:
a. CONNECTIONS SHALL BE DESIGNED FOR ON HALF THE TOTAL UNIFORM LOAD
CAPACITY OR THE REACTION GIVEN ON THE DRAWINGS.
b. ALL SHOP CONNECTIONS SHALL BE WELDED OR BOLTED.
c. ALL FIELD CONNECTIONS SHALL BE BOLTED UNLESS WELDS ARE SPECIFIED.
d. BOLTS SHALL BE ASTM F3125 IN ACCORDANCE WITH AISC 329.
e. MINIMUM BOLT DIAMETER SHALL BE 3/4"
f. MINIMUM CONNECTIONS ANGLE THICKNESS SHALL BE 3/8"
g. MINIMUM GUSSET PLATE THICKNESS SHALL BE 3/8".
h. BOLT DIAMETER FOR SECONDARY MEMBERS (GIRTS, STAIRS) MAY BE 5/8" (MIN.).
i. ALL CONNECTIONS SHALL BE SYMMETRICAL ONE SIDED CONNECTIONS ARE NOT
ALLOWED, UNLESS SPECIFICALLY NOTED OTHERWISE.
j. ALL CONNECTIONS SHALL BE 2-BOLT MINIMUM.
9. ALL STEEL SHALL BE SHOP PRIMED.
C. MISCELLANEOUS METALS
1. POSTS SHALL BE SPACED AT 6'-0" (MAX.) CENTERS WITH TOP RAIL, TWO INTERMEDIATE
RAIL AND 1/4X4" TOE PLATE. ALL HANDRAILS SHALL BE BOLTED TO SUPPORTS UNLESS
NOTED OTHERWISE.
2. WHERE HANDRAIL TURNS A CORNER, PROVIDE A POST WITHIN 18" OF THE CORNER.
3. HANDRAIL SHALL BE SHOP WELDED CONSTRUCTION WITH ROUGH EDGES AND WELDS
GROUND SMOOTH.
STEEL JOISTS AND JOIST GIRDERS
A. ALL STEEL JOISTS AND JOIST GIRDERS SHALL BE DESIGNED AND MANUFACTURED
IN ACCORDANCE WITH SJI 'STANDARD SPECIFICATIONS - LOAD TABLES AND
WEIGHT TABLES FOR STEEL JOISTS AND JOIST GIRDERS, 2010'. TYPE AS SHOWN
ON THE DRAWINGS.
B. PLACEMENT OF MECHANICAL UNITS AND HANGERS SUPPORTED BY ROOF JOISTS
IS SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER.
C. THE DESIGN OF ALL JOIST, GIRDER MEMBERS, AND ELEMENTS SHOWN ON THE
DRAWINGS IS FOR THE IN-PLACE, COMPLETED BUILDING. ALL LOADING CRITERIA
AND VERIFICATION OF DESIGN FOR LOADINGS SUCH AS HANDLING,
TRANSPORTATION AND ERECTION ARE THE SOLE RESPONSIBILITY OF THE JOIST
MANUFACTURER.
D. JOIST MANUFACTURER SHALL DESIGN AND PROVIDE SPECIAL JOIST SEATS WHEN
THE SUPPORT BEARING WIDTH IS LESS THAN SJI REQUIREMENTS.
E. THE CONTRACTOR AND FABRICATOR SHALL REVIEW THE CONTRACT
DOCUMENTS AND INCORPORATE ANY ADDITIONAL PROVISIONS NECESSARY TO
MEET APPLICABLE SAFETY REGULATIONS. COMPLIANCE IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR.
F. ROOF JOISTS SHALL BE DESIGNED FOR A NET UPLIFT OF 10 PSF UNLESS NOTED
OTHERWISE.
G. PROVIDE 3-1/2" DEEP SEATS ON ALL K-JOISTS, UNLESS NOTED OTHERWISE.
H. SEE [9/S511] FOR JOIST REINFORCEMENT REQUIRED AT EQUIPMENT LOADS.
I. STEEL JOIST SUPPLIER SHALL FURNISH ALL BRACING, WALL ANCHORS, HEADERS
AND BOTTOM CHORD EXTENSIONS, ETC. AS NECESSARY TO PROVIDE A
COMPLETE INSTALLATION.
J. ALL STEEL JOISTS SHALL BE WELDED TO THE SUPPORTING MEMBERS UNLESS
NOTED OTHERWISE.
K. PROVIDE BRIDGING IN ACCORDANCE WITH SJI SPECIFICATIONS. EACH JOIST
SHALL BE ADEQUATELY BRACED LATERALLY BEFORE ANY LOADS ARE APPLIED.
L. THE JOIST MANUFACTURER IS RESPONSIBLE FOR AND SHALL SUBMIT SHOP
DRAWINGS FOR APPROVAL. A CERTIFIED LETTER STATING ALL STANDARD JOISTS
CONFORM TO SJI SPECIFICATIONS SHALL BE SUBMITTED TO THE ENGINEER.
CERTIFIED CALCULATIONS BY AN ENGINEER REGISTERED IN THE STATE OF THE
PROJECT SHALL BE SUBMITTED FOR ALL JOIST GIRDERS AND SPECIAL JOISTS.
NON-COMPOSITE STEEL DECK
A. ALL STEEL DECK SHALL BE DESIGNED AND SELECTED IN ACCORDANCE
WITH THE SDI DESIGN MANUAL NO. 31.
B. STEEL DECK SHALL BE MANUFACTURED FROM STEEL CONFORMING TO
ASTM A1008 PAINTED GRADE 33 OR HIGHER (33 KSI YIELD STRENGTH)
WHERE APPLICABLE.
C. DECK ANCHORAGE SHALL BE MADE WITH 5/8" DIAMETER PUDDLE WELDS AT
SUPPORTS AND EDGES AND #10 TEK SCREWS AT SIDELAPS. FASTENER
PATTERNS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:
1. 1-1/2" ROOF DECK: 36/4 PATTERN (12" ON CENTER) AT SUPPORTS AND
12" ON CENTER AT EDGES. PROVIDE (1) ONE SIDELAP FASTENERS PER
DECK SPAN.
D. ROOF DECK SHALL BE PAINTED TYPE B. WIDE RIB, DEPTH AND GAUGE AS
INDICATED ON THE DRAWINGS.
E. SUBMIT SHOP DRAWINGS FOR DECK PLACEMENT SHOWING DECK
CHARACTERISTICS, ANCHORAGE DETAILS AND ACCESSORIES.
F. PROVIDE REINFORCING AND CLOSURE STRIPS FOR ALL OPENINGS UP TO
13 INCHES IN ACCORDANCE WITH SDI MOC2, 2006. FOR OPENINGS LARGER
THAN 13 INCHES, FOLLOW TYPICAL FRAMED ROOF OPENING DETAIL
UNLESS NOTED OTHERWISE.
FASTENER NOTES
A. FASTENERS ARE BASED ON HILTI NORTH AMERICA. (1-800-879-8000,
www.US.HILTI.COM) UNLESS NOTED OTHERWISE.
B. SUBSTITUTIONS WILL BE CONSIDERED PROVIDED CONTRACTOR SUPPLIES
DATA WHICH SHOWS EQUIVALENT FASTENER CAPACITY. EMBEDMENT
DEPTH, FASTENER SPACING AND EDGE DISTANCES MUST BE CONSIDERED.
C. FASTENER TYPES:
ADHE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .