This is a Material Standard specification document issued by Seattle City Light, a municipal utility in Washington State, establishing requirements for Class 0 electrical insulating rubber gloves used by utility workers. The standard specifies gloves in eight sizes (ranging from size 7 to size 12) with corresponding stock numbers, establishing that these gloves are appropriate for use only on systems rated 1,000 volts or less. The gloves must meet ASTM D 120-08 and ASTM F 496-08 industry standards, featuring 14-inch length with yellow exterior and interior coloring, straight cuff design, and a proof test rating of 5,000 volts AC (rms). The standard mandates halogenation treatment and requires red class color marking. Packaging must include Seattle City Light's stock number on the exterior of each package, and all gloves must be marked in accordance with ASTM D-120 specifications.

The document identifies two approved manufacturers: Chance (Hubbell Power Systems) and Salisbury (by Honeywell), with specific catalog numbers designated for each size and stock number. This material standard is referenced in a related City of Seattle solicitation for Electric Utility Grade Lineman Gloves and Rubber Goods, which seeks to replace the current contract (Contract 3750) with an average annual spend of approximately $45,000. The solicitation explicitly states that substitutes will not be accepted and that bidders must provide products from the manufacturers listed in the material standards. The standard became effective August 15, 2018, superseding previous versions dated March 7, 2018.

View the file

Other files

File Type Posted
Electric_Utility_Grade_Lineman_Gloves_and_Rubber_Goods.pdf PDF
Contract_Terms_and_Conditions.docx DOCX document
ITB#_CL0-6520_Re-Bid_-_Insurance_Requirements_and_Transmittal.docx DOCX document
7634.62.pdf PDF
7634.21.pdf PDF
7634.20.pdf PDF
7633.20.pdf PDF
4010.60.pdf PDF
Insurance_Requirements_and_Transmittal.doc DOC document
Rebate_Report_Template.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Seattle City Light

MATERIAL STANDARD

standard number:

superseding:

effective date:

page:

7634.60

March 7, 2018 August 15, 2018

Standards Coordinator Laura Vanderpool

Standards Supervisor John Shipek

Unit Director Andrew Strong

Gloves, Insulating, Rubber, Class 0

1. Scope

This standard covers the requirements for Class 0 electrical insulating rubber gloves.

The requirements for leather protector gloves, appropriate for use with Class 0 rubber gloves, are specified in SCL 7634.20.

The requirements for Class 2 insulating rubber gloves are specified in SCL 7634.62.

This standard applies to the following Seattle City Light stock numbers:

Stock No. Size

014333 7

014334 8

014336 9

013258 9-1/2

014337 10

013259 10-1/2

014338 11

014339 12

2. Appl icat ion

The phase-to-ground voltage to which the rubber insulating gloves may be exposed shall be limited to the maximum use voltage (see detailed requirements) of the glove.

The gloves specified in this standard are only appropriate for use on systems rated 1000 V or less.

Refer to WAC 296-45 and ASTM F-496, Section 3 for more information.

3. Industry Standards

Gloves shall meet the requirements of the following industry standards:

ASTM D 120-08 - Standard Specification for Rubber Insulating Gloves

ASTM F 496-08 - Standard Specification for In- Service Care of Insulating Gloves and Sleeves

4. Detai led Requirements

Gloves shall have the following electrical ratings and attributes:

type I, non-resistant to ozone class 0 length 14 in length tolerance, in +0, -1/2 glove color (outside) yellow glove color (inside) yellow cuff design straight halogenation treatment required, or approved equal treatment class color red proof test 5,000 V ac (rms) maximum use voltage

1,000 V ac (rms)

Seattle City Light

MATERIAL STANDARD

Gloves, Insulating, Rubber, Class 0 standard number:

superseding:

effective date:

page:

7634.60

March 7, 2018 August 15, 2018

5. Marking

Each glove shall be marked according to the requirements of ASTM D-120, Section 7.

6. Testing

Gloves shall be tested according to the requirements of ASTM D-120 and F-496.

Test data that establishes compliance with the requirements of ASTM D-120 and ASTM F-496 shall be provided upon request.

7. Packaging

Gloves shall be packaged according to the requirements of ASTM D-120, Section 15, with the following clarification that the outside of each package shall be marked with Seattle City Light's Stock Number.

8. Issuance

PR

9. Approved Manufacturers

Manufacturers and Catalog Numbers

Stock No. Size Chance Salisbury

014333 7 PSC014Y7 E014Y/7

014334 8 PSC014Y8 E014Y/8

014336 9 PSC014Y9 E014Y/9

013258 9-1/2 PSC014Y9H E014Y/9H

014337 10 PSC014Y10 E014Y/10

013259 10-1/2 PSC014Y10H E014Y/10H

014338 11 PSC014Y11 E014Y/11

014339 12 PSC014Y12 E014Y/12

10. References

SCL Material Standard 7634.20; “Gloves, Leather Protectors”

SCL Material Standard 7634.62; “Gloves, Insulating, Rubber, Class 2”

WAC 296-25505 (1); "Personal Protective Equipment"; Washington Administrative Code;

Washington State

11. Sources

ASTM F 696-06: “Standard Specification for Leather Protectors for Rubber Insulating Gloves and Mittens;” ASTM

ASTM F 819-08: “Standard Terminology Relating to Electrical Protective Equipment for Workers;”

ASTM

Chance product catalog; Chance (Hubbell Power Systems)

Chance website; www.hubbellpowersystems.com

The Lineman's and Cableman's Handbook;

McGraw-Hill Professional; 9th edition

Salisbury product catalog; Salisbury

Salisbury by Honeywell website;

www.whsalisbury

Shipek, John; SCL Standards Engineer; originator, and subject matter expert for 7634.60 (john.shipek@seattle.gov)

Tawney, Everette; subject matter expert for

7634.60 (everette.tawney@seattle.gov) mailto:john.shipek@seattle.gov

File details come from the government source that posted it. Updated .