7-448-2023-040460 Add 1 Exhibit A.pdf

PDF 350 KB Posted

Attached to
ASR Phase 3 Recharge Basins
Solicitation number
260221
Issued by
Sedgwick County, Kansas

About this file

This is a technical exhibit document prepared for the City of Wichita's Public Works & Utilities Department as part of the ASR Phase 3 Recharge Basins construction project in Kansas. The document, titled "Exhibit A - Reinforcing Steel Requirements for Concrete Headwall," provides detailed engineering specifications and design drawings for recharge basin infrastructure components. The specifications include concrete headwall construction details with reinforcing steel placement requirements, slope protection measures utilizing riprap with a D50 of 12 inches, filter blanket installation, and a flanged mounted flap gate for the recharge outlet. The drawings indicate elevation specifications for recharge basins RB09 at 1405.0 feet and RB15 at 1396.0 feet, with 3 horizontal to 1 vertical slope ratios. Reinforcing steel requirements are specified throughout, including #4 and #5 rebar placements at 12-inch centers, with detailed callouts for centered-in-wall (CIW) placement and corner (CB) reinforcement configurations.

The technical specifications include tension development length requirements for standard 90-degree hooks based on ACI 318 standards, with hook lengths varying by bar size and concrete strength (f'c values of 4000 psi noted). The document provides a reference table for tension development lengths specifying hook lengths of 7-9 inches for #4 bars and 8-12 inches for #5 bars depending on concrete strength and application. These specifications establish the engineering requirements and construction standards that bidders must meet for the concrete headwall and associated basin components on this public infrastructure project.

View the file

Other files

File Type Posted
4-260221 Bid Table Add01 Rev.pdf PDF
1-260221 Bid Table.pdf PDF
3-BP 448-2023-040460.pdf PDF
6-Add01 448-2023-040460.pdf PDF
5-448-2023-040460 KS20260162.pdf PDF
2-BPAttach 448-2023-040460 Revised.pdf PDF
8-Add02 448-2023-040460.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0.33

0.67'

0.83

5.33'

2.50'

1.50'

6.16'

5.83'

2.00'

1.00'

2.17'

3.00' 6.00' 3.00'

1.00'

0.67'

1.5

1'

6" FILTER BLANKET

18" RIPRAP THICKNESS

D50 = 12"

0.50'

PIPE FLANGED

MOUNTED

FLAP GATE

EDGE OF CONCRETE

RB09 EL. 1405.0

RB15 EL. 1396

3H:1V 3H:1V

RECHARGE BASIN

RB09 EL. 1405.0

RB15 EL. 1396.0

RECHARGE OUTLET DETAIL 1

#5 @ 12 CIW

RECHARGE BASIN

SLOPE PROTECTION

#4 @ 12

ADD #5 CIW

ON SLOPE

#4 @ 12 CIW

1.50' 0.83'

0.67'

5.33'

2.00'

4.00'1.00' 1.00' 1.00' 1.00'

24db

(TYP.)

#5 @ 12 O.C.

#5 @ 12 O.C.

1SECTION

#5 @ 12 CENTERED IN WALL (CIW)

(TYP)

#5 @ 12 CIWADD 4-#5 EF

#5 CB @ 12 24X24 (TYP)

λ = 1.0 FOR NORMAL WEIGHT CONCRETE = β = 1.0 FOR UNCOATED BARS

TABLE BASED ON ACI 318

TENSION DEVELOPMENT LENGTH (INCHES)

FOR STANDARD 90° HOOKS

BAR SIZE

f'c (psi)

4000 HOOK LENGTH 12d b

#4 7 6

#5 9 8

ΨE

d b d

6d b

#3 THRU #8

l dh

CRITICAL

SECTION

TENSION DEVELOPMENT LENGTH FOR STANDARD 90 DEGREE HOOK

EXHIBIT A - REINFORCING STEEL REQUIREMENTS FOR CONCRETE HEADWALL

File details come from the government source that posted it. Updated .