This is an architectural site and floor plan document prepared by SPE Architects for the American Preparatory Academy West Valley 2/3 Campus expansion project located at 3636 West and 3100 South in West Valley City, Utah. The project is a two-phase addition involving an elementary classroom addition (Phase 1, 7,530 square feet on Level 1) and a secondary addition with auditorium and support spaces (Phase 2, 27,960 square feet on Level 1 and 13,361 square feet on Level 2), along with a future food service building shell of 2,424 square feet included as an alternate bid item. Phase 1 is scheduled to be completed by August 2027. The plans include detailed floor layouts for multiple levels showing classroom configurations, administrative spaces, gymnasiums, auditorium facilities, music rooms, dining areas, and support facilities. The site plan indicates the location of utility infrastructure including fire risers, water lines, electrical systems, storm drain modifications, and landscape elements. A mandatory pre-proposal meeting is scheduled for Thursday, August 27th at 10:00 AM on-site, with the submission deadline extended to Thursday, September 10th at 5:00 PM. The Utah Charter Academies (UCA), conducted through the State of Utah Division of Purchasing, is procuring general contracting services and all necessary materials for project completion.
The contract will be awarded to a single responsive and responsible vendor with the highest score as justified by procurement code. Vendor pricing must be guaranteed for six months, and the contract term extends through project completion. The project work is structured in two overlapping phases, with Phase 1 sitework and Phase 2 construction anticipated to commence at the end of the 2026/27 school year. As of the schematic design phase dated August 6, 2026, the plans are marked "For Review Only" and "Not for Permit" or "Not for Construction." The document notes that coordination with landscape, civil, and other engineering drawings is required for complete implementation of the project scope.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T R
U C
K D
O C
K
VAN
W
E S
T S
T R
E E
T
VAN
B A
N G
E R
T E
R H
W Y
3100 SOUTH STREET
FUTURE
FOOD
SERVICE
PHASE 1
PHASE 2
LEVEL 1 - 7,530 sf
LEVEL 1 - 27,960 sf LEVEL 2 - 13,361 sf FUTURE FOOD SERVICE - 2,424 sf
2,424 SF
AS-102
A1
COPYRIGHT: © 2025 SPE ARCHITECTS
1 2 3 4 5
1 2 3 4 5
A
B
C
D
A
B
C
E
SHEET NUMBER:
SHEET TITLE:
ISSUED:
NO. DATE DESCRIPTION
PROJECT NAME:
REVISIONS:
NO. DATE DESCRIPTION
L a s t P lo tt e d
D
E
PROFESSIONAL STAMP:
CONSULTANT INFORMATION:
1 06/21/26 SCHEMATIC IN PROGRESS
P.O. Box 517 - Kaysville, Utah 84037 info@spe-architect.com 801.298.1368
ARCH I T E C T S
SPE ARCHITECTS
A M
E R
I C
A N
P R
E P
A R
A T
O R
Y A
C A
D E
M Y
W
V C
/3
C A
M P
U S
DESIGNED BY:
CHECKED BY:
PROJECT #:
DRAWN BY:
25-10
ELM/GTE
ELM
ELM
C L
A S
S R
O O
M S
A
U D
I T
O R
I U
M A
D D
I T
I O
N
P H
A S
E
A
R E
A K
FOR REVIEW
ONLY
NOT FOR PERMIT
NOT FOR CONSTRUCTION
/6
/2
:3
:3
P M
A u to d e s k D o c s /2
-1
W
V C
T h e a te r/
W V
C
-A R
C H
R rv t
SITE PLAN
OVERALL
AS-101
W
E S
T
S
O U
T H
W E
S T
V A
L L E
Y C
IT
Y
U
T A
H
0 60' 90' 120'30'
PR
O
JEC
T
N O R
TH
T R
U E
N O
R T
H
1" = 30'-0"A1 SITE PLAN - OVERALL
UP
DN
UP
DN
FIR
E
R
ISER
G
E
8" FIRE
2" WATER
8" FIRE
2" WATER
8" FIRE
2" WATER
2" WATER
ABANDON ???
2" W
A
TE
R
22 15
W E
S T
S T
R E
E T
5 20
8 7
12 PHASE 1
ADDITION
PHASE 2
ADDITION
LEVEL 1 = 7,530 sf
LEVEL 1 - 27,960 sf LEVEL 2 - 13,361 sf FUTURE FOOD SERVICE - 2,424 sf
FIRE
RISER
REQUIRED SETBACK
20' - 0"
21' +/-
7 8
5 5
FDC
FUTURE
FOOD
SERVICE
2,424 SF
NOTE:
FOOD SERVICE
BUILDING SHELL
IS BID ALT. #1
OF PHASE 2
34 36 35 37
PHASING NOTE:
IT IS ANTICIPATED THAT PHASE 1 SITEWORK
AND PHASE 2 CONSTRUCTION WILL COMMENCE
AT THE END OF THE 2026/27 SCHOOL YEAR.
THEREFORE, THIS PLAN DOES NOT
DIFFERENTIATE BETWEEN PHASES
# KEYED NOTES
1. EXISTING BUILDING TO REMAIN - PROTECT FROM DAMAGE.
2. EXISTING FIRE HYDRANT - PROTECT FROM DAMAGE.
3. NEW LANDSCAPING - SEE LANDSCAPE DRAWINGS.
4. EXISTING LANDSCAPING AND OTHER IMPROVEMENTS IN THIS AREA TO
REMAIN AND BE PROTECTED FROM DAMAGE - WHERE NEW WORK
TIES INTO EXISTING, MODIFY EXISTING AS REQUIRED - COORDINATE
WITH LANDSCAPE AND CIVIL DRAWINGS.
5. NEW CONCRETE SIDEWALK - SEE CIVIL DRAWINGS.
6. EXISTING CONCRETE SIDEWALK - PROTECT FROM DAMAGE.
7. NEW CONCRETE CURB AND/OR GUTTER - SEE CIVIL DRAWINGS.
8. EXISTING CURB AND GUTTER - PROTECT FROM DAMAGE - SEE CIVIL
DRAWINGS.
9. NEW ASPHALT PAVING - SEE CIVIL DRAWINGS.
10. EXISTING ASPHALT PAVING TO REMAIN - PROTECT FROM DAMAGE
11. EXISTING ASPHALT PAVING TO BE REMOVED - SAW CUT - SEE CIVIL
DRAWINGS.
12. NEW CONCRETE PAVING - SEE CIVIL DRAWINGS.
13. EXISTING STORM DRAIN SYSTEM - PROTECT FROM DAMAGE.
14. EXISTING STORM DRAIN SYSTEM TO BE REMOVED - SEE CIVIL
DRAWINGS.
15. NEW STORM DRAIN - TIE INTO EXISTING SYSTEM - SEE CIVIL
DRAWINGS.
16. NEW CATCH BASIN - SEE CIVIL DRAWINGS.
17. NEW TRENCH DRAIN - SEE CIVIL DRAWINGS.
18. NEW UNDERGROUND STORM DRAIN DETENTION SYSTEM - SEE CIVIL
DRAWINGS.
19. EXISTING CHAIN LINK FENCING SYSTEM TO REMAIN - PROTECT FROM
DAMAGE.
20. EXISTING CHAIN LINK FENCING AND ALL RELATED MATERIALS TO BE
REMOVED.
21. NEW 6' CHAIN LINK FENCING SYSTEM TO MATCH EXISTING - SEE SPEC,
22. NEW FIRE LINE TO NEW FIRE RISER (IF REQUIRED)
23. NEW ASPHALT PATCH INTO EXISTING ASPHALT BASKETBALL COURT
24. EXISTING SANITARY SEWER LATERAL - SEE CIVIL DRAWINGS
25. NEW OIL/WATER SEPARATOR - SEE CIVIL DRAWINGS
26. NEW SAMPLING MANHOLE - SEE CIVIL DRAWINGS
27. NEW SEWER LATERAL - SEE CIVIL DRAWINGS
28. EXISTING ELECTRICAL EQUIPMENT
29. NEW CURB RAMP - SEE CIVIL DRAWINGS
30. EXISTING ARTIFICIAL TURF - MODIFY / REMOVE / REPLACE AS
REQUIRED FOR REDUCED PLAYGROUND SIZE AND NEW UTILITIES
INSTALLED THROUGH EXISTING PLAYGROUND
31. NEW UNDERGROUND ELECTRIC SERVICE TO EXISTING
TRANSFORMER - COORDINATE WITH ROCKY MOUNTAIN POWER
32. NEW CURB RAMP WITH 1:10 SLOPE MAX
33. NEW FIRE DEPARTMENT CONNECTION
34. EXISTING 2" CULINARY WATER TO BE ABANDONED WHERE DASHED -
SEE CIVIL DRAWINGS
35. NEW 2" CULINARY WATER - SEE CIVIL DRAWINGS
36. EXISTING 8" FIRE LINE TO BE ABANDONED WHERE DASHED - SEE CIVIL
DRAWINGS
37. NEW 8" FIRE LINE - SEE CIVIL DRAWINGS
38. NEW 8" CONCRETE RETAINING WALL - SEE CIVIL DRAWINGS
COPYRIGHT: © 2025 SPE ARCHITECTS
1 2 3 4 5
1 2 3 4 5
A
B
C
D
A
B
C
E
SHEET NUMBER:
SHEET TITLE:
ISSUED:
NO. DATE DESCRIPTION
PROJECT NAME:
REVISIONS:
NO. DATE DESCRIPTION
L a s t P lo tt e d
D
E
PROFESSIONAL STAMP:
CONSULTANT INFORMATION:
1 06/21/26 SCHEMATIC IN PROGRESS
P.O. Box 517 - Kaysville, Utah 84037 info@spe-architect.com 801.298.1368
ARCH I T E C T S
SPE ARCHITECTS
A M
E R
I C
A N
P R
E P
A R
A T
O R
Y A
C A
D E
M Y
W
V C
/3
C A
M P
U S
DESIGNED BY:
CHECKED BY:
PROJECT #:
DRAWN BY:
25-10
ELM/GTE
ELM
ELM
C L
A S
S R
O O
M S
A
U D
I T
O R
I U
M A
D D
I T
I O
N
P H
A S
E
A
R E
A K
FOR REVIEW
ONLY
NOT FOR PERMIT
NOT FOR CONSTRUCTION
/6
/2
:3
:4
P M
A u to d e s k D o c s /2
-1
W
V C
T h e a te r/
W V
C
-A R
C H
R rv t
ARCHITECTURAL
SITE PLAN
AS-102
W
E S
T
S
O U
T H
W E
S T
V A
L L E
Y C
IT
Y
U
T A
H
1" = 20'-0"A1 CONCEPT SITE PLAN
0 40' 60' 80'20'
PR
O
JEC
T
N O R
TH
T R
U E
N O
R T
H
HIGH SCHOOL GYMNASIUM
SCENE SHOP
TRUCK DOCK
LOWER SCHOOL GYMNASIUM
STAGE
CONCESSIONS
FOOD COURT
SET & PROP
STORAGE
LOWER
ENTRY
STAGE
CONTROL
BLACK BOX /
DRAMA
CLASSROOM
WEIGHT
ROOM
DRESSING
DRAMA
OFFICE
DRESSING
FOOD
DELIVERY
STAGING
FUTURE
ELEV.
VEST. 92 SEATS
S/L
LOCK
RR
STAGE SUPPORT
RAMP DOWN
R A
M P
D O
W N
R A
M P
U P
R A
M P
U P
EXISTING
ELEV.
DANCE
S/L LOCK
MEN
WOMEN
RRRR
A R
B O
R P
IT
TICKETS
TICKETS
LATIN
BREAKOUT
ENGLISH/
HEALTH
STAFF WORK
ROOM
ADMIN.
TEACHING
CLASSROOM
CLASSROOMP
A
N T
R Y
T&C STORAGE
LOBBY
ENGLISH
SCIENCE
CLASSROOM
698/20/35
CLASSROOM
1234/20/62
CLASSROOM
637/20/32 CLASSROOM
576/20/29
CLASSROOM
682/20/34
CLASSROOM
456/20/23
STORAGE
421/500/1
OFFICE
268/100/3
OFFICE
UTILITY
254/200/2
MATH
HISTORY
ELEV
BREAKOUT
STORAGE
1st GRADE
1st GRADE
1st GRADE
2nd GRADE
2nd GRADE
3rd GRADE
2nd GRADE
3rd GRADE
3rd GRADE
BREAKOUT
BREAKOUT
BOYS
GIRLS
KINDERGARTEN
4th GRADE
KINDERGARTEN
4th GRADE
4th GRADE
KINDERGARTEN
STAFF BREAK
WORK ROOM
5th GRADE
5th GRADE
5th GRADE
CURRICULUM
CONFERENCE
ROOM
ADMIN.
SICK
ACAD.
DIR.
EXEC.
DIR.
ADMIN.
OFFICE
STORAGE
MULTI-PURPOSE ROOM
ELEM. ORCHESTRA
BREAKOUT
BREAKOUT
6th GRADE
6th GRADE
6th GRADE
ELEM. ART
EQUIP
BOYS
GIRLS
BOYS GIRLS
BOYS
GIRLS
STORAGE
SVR
CLASSROOM
BUS. MGR.
OPERATIONS
BREAKOUT
PANTRY
MATH
E
LE
C T
OFFICE
OFFICE
OFFICE
OFFICE
U P
100' - 0"
97' - 8"
97' - 6"
97' - 6"
100' - 0"
FIRE
RISER
8,037 sf
FUTURE
FOOD
SERVICE
CLASSRM 5
CLASSRM 6
CLASSRM 3
CLASSRM 4
CLASSRM 2
CLASSRM 1
BREAKOUT
BREAKOUT
GIRLS
BOYS
STAFF
JAN
ELECT
BREAKOUT
P2-AE-105
A1
P2-AE-106
AE-111
A1
K-6 ADDITION
AE-104
A1
PHASE 2 PLANS
SEE
PHASE 2 PLANS
SEE
COPYRIGHT: © 2025 SPE ARCHITECTS
1 2 3 4 5
1 2 3 4 5
A
B
C
D
A
B
C
E
SHEET NUMBER:
SHEET TITLE:
ISSUED:
NO. DATE DESCRIPTION
PROJECT NAME:
REVISIONS:
NO. DATE DESCRIPTION
L a s t P lo tt e d
D
E
PROFESSIONAL STAMP:
CONSULTANT INFORMATION:
1 06/21/26 SCHEMATIC IN PROGRESS
P.O. Box 517 - Kaysville, Utah 84037 info@spe-architect.com 801.298.1368
ARCH I T E C T S
SPE ARCHITECTS
A M
E R
I C
A N
P R
E P
A R
A T
O R
Y A
C A
D E
M Y
W
V C
/3
C A
M P
U S
DESIGNED BY:
CHECKED BY:
PROJECT #:
DRAWN BY:
25-10
ELM/GTE
ELM
ELM
C L
A S
S R
O O
M S
A
U D
I T
O R
I U
M A
D D
I T
I O
N
P H
A S
E
A
R E
A K
FOR REVIEW
ONLY
NOT FOR PERMIT
NOT FOR CONSTRUCTION
/6
/2
:3
:3
P M
A u to d e s k D o c s /2
-1
W
V C
T h e a te r/
W V
C
-A R
C H
R rv t
FLOOR PLAN
LEVEL 1
OVERALL
AE-101
W
E S
T
S
O U
T H
W E
S T
V A
L L E
Y C
IT
Y
U
T A
H
1" = 20'-0"A1 FLOOR PLAN - LEVEL 1
0 32' 48' 64'16'
PROJECT
NORTH
TR
U E
N O R
TH
B
ID
G
E
S L
O P
E D
CLASSROOM
HIGH SCHOOL GYMNASIUM
BELOW
ORCHESTRA 2
SCENE SHOP
BELOW
OUTDOOR
PATIO
LOWER SCHOOL GYMNASIUM
BELOW
OPEN TO
BELOW
ELEV
OPEN
TO
BELOW
COSTUME
STORAGE
CLASSROOM
CLASSROOM
CLASSROOM
CHEMISTRY
BIOLOGY
TO MAIN ENTRY
BAND 1
VERIFY
LOCATION
.1
CHOIR
STAFF LOUNGE /
CONFERENCE
ROOM
BAND 2
OFFICE
OFFICE
FUTURE
ELEV INSTRUMENT STORAGE
ORCHESTRA 1
OFFICE
CLST
STAGE SUPPORT
BELOW
O P
E N
T O
B E
L O
W
SOUND
CONTROL
AUDITORIUM LOBBY
OPEN
TO
BELOW
S/L LOCK
S/L LOCK
WOMEN RR
RAMP DOWN
INSTRUMENT
STORAGE
HOOD
EXHAUST
FO
O D
S E R V
IC
TU
B
LA
C K
O
XR
TU
MEN RR
FAMILY RR
O P
E N
T O
B E
L O
W
NEW
CLASSROOM
NEW
CLASSROOM
NEW
CLASSROOM
NEW
CLASSROOM
P2-AE-108
P2-AE-107
P2-AE-108
CLASSROOM
OFFICE
OFFICE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
OFFICE
OFFICE
ADMINISTRATION
OFFICE
OFFICE
OFFICE
ENTRY LOBBY
BELOW
JAN.
STORAGE
S
TO
R A
G
LO
W
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
LOWER SCHOOL
CLASSROOMS
BELOW
LOWER SCHOOL
CLASSROOMS
BELOW
LOWER SCHOOL
MULTIPURPOSE
ROOM BELOW
S
TO
R A
G E
STAGE BELOW
RECORDING
1" = 20'-0"A1 FLOOR PLAN - LEVEL 3
COPYRIGHT: © 2025 SPE ARCHITECTS
1 2 3 4 5
1 2 3 4 5
A
B
C
D
A
B
C
E
SHEET NUMBER:
SHEET TITLE:
ISSUED:
NO. DATE DESCRIPTION
PROJECT NAME:
REVISIONS:
NO. DATE DESCRIPTION
L a s t P lo tt e d
D
E
PROFESSIONAL STAMP:
CONSULTANT INFORMATION:
1 06/21/26 SCHEMATIC IN PROGRESS
P.O. Box 517 - Kaysville, Utah 84037 info@spe-architect.com 801.298.1368
ARCH I T E C T S
SPE ARCHITECTS
A M
E R
I C
A N
P R
E P
A R
A T
O R
Y A
C A
D E
M Y
W
V C
/3
C A
M P
U S
DESIGNED BY:
CHECKED BY:
PROJECT #:
DRAWN BY:
25-10
ELM/GTE
ELM
ELM
C L
A S
S R
O O
M S
A
U D
I T
O R
I U
M A
D D
I T
I O
N
P H
A S
E
A
R E
A K
FOR REVIEW
ONLY
NOT FOR PERMIT
NOT FOR CONSTRUCTION
/6
/2
:3
:3
P M
A u to d e s k D o c s /2
-1
W
V C
T h e a te r/
W V
C
-A R
C H
R rv t
FLOOR PLAN -
LEVELS 2-3
AE-102
W
E S
T
S
O U
T H
W E
S T
V A
L L E
Y C
IT
Y
U
T A
H
0 32' 48' 64'16'
PROJECT
NORTH
TR
U E
N O
TH
KD
KD
KA
KA
K2
K2
K1
K1 C1
AE-301
C1
AE-301
B1
AE-301
B1
AE-301
A1
AE-301
A1
AE-301
C1
AE-302
B1
AE-302
A1
AE-302
K3
K3
K4
K4
K5
K5
K6
K6
K7
K7
VESTIBULE
K01
CORRIDOR
K02
688 SF
CLASSROOM
K03
693 SF
CLASSROOM
K04
ELECT
K05
JAN
K06
BOYS RR
K07
GIRLS RR
K08
STAFF RR
K09
272 SF
BREAKOUT
K10
195 SF
BREAKOUT
K11
324 SF
BREAKOUT
K12
698 SF
CLASSROOM
K13
698 SF
CLASSROOM
K14
698 SF
CLASSROOM
K15
727 SF
CLASSROOM
K16
A3
AE-312
A5
AE-312
AE-201
B1
AE-201
C1
AE-201
A1
KC
KC
KB
KB
A1
AE-312
A2
AE-312
AE-401
A1
K01A
K02A
K03A
K04A
K03B
K16A
K14A
K12A
K06A
K05A
K10A
K11A
K09A
K14B
K13B
K13A
K15A
K16B
K15B
K04B
B2
AE-504
SF100
SF101
SF102
W02
W01
W01
W01
SF103
SF103
KD
KD
KA
KA
K2
K2
K1
K1
70' - 8"
2' - 0"
3' - 4"
5' - 4"
3' - 4"
3' - 4"
3' - 4"
3' - 4"
3' - 4"
3' - 0"
7' - 0"
33' - 4"
20' - 8"
6' - 0"
22' - 0"
6' - 0"
23' - 4"
6' - 0"
25' - 8"
25' - 8"
25' - 8"
25' - 10 9/16"
7 5/8"
5' - 0"
5' - 0"
10' - 0"
3' - 0"
3' - 0"
5' - 4"
3' - 0"
FINISH14' -
3 1/8"
FINISH14' -
3"
7 5/8"
29' - 0 1/8"
10' - 9 7/8"
28' - 10 3/4"
7 5/8"
8"
K3
K3
K4
K4
K5
K5
K6
K6
8' - 0" +/-
8' - 10 1/2"
25' - 8"
25' - 8"
25' - 8"
23' - 5 1/2"
4' - 9"
K7
K7
7 5/8"2 7/8"
7 5/8"
10 1/2"
KC
KC
KB
KB
40' - 8 1/2"
26' - 9 1/2"
3' - 2"
1' - 2"
7 5/8"
3 3/8"7 5/8"
2' - 0"
8"
3' - 6 1/2"
25' - 8"
25' - 8"
23' - 5 1/2"
4' - 9"
11"
79' - 6 1/2"
2' - 5 1/2"
34' - 0" +/-
10' - 8"
40' - 8"
10' - 8"
21' - 4"
4' - 9"
8' - 0" +/-
114' - 1"
G
RID
4 5/8"
5' - 4"
1' - 11 5/16"
5' - 0"
5' - 0"
5' - 4"
3' - 2 1/2"
2' - 1 1/2"
8' - 0"
2' - 8"
3' - 0"
2 3/4"
3' - 0"
5' - 6 1/2"
FINISH
13' - 6 1/2"
FINISH
13' - 5 5/8"
CM
U
3' - 4"
CM
U
3' - 4"
CM
U
8' - 8"
3"
4 1 /2"
3"
2 7 /8"
10' - 9 7/
8"
2 7 /8"
6' - 10 1/8"
8"
FIN
ISH14' -
0"
FIN
ISH14' -
1 1/ 8"
FIN
ISH
25' - 11 1/4"
25' - 6 7/8"
FIN
ISH14' -
3"
FIN
ISH14' -
3"
FIN
ISH14' -
3"
2' - 9"
17' - 8"
5' - 0"
3" 6' - 11 1/2"
14' - 0 3/4"
4' - 5"
8' - 8"
4' - 0"
AE-401
A1
2' - 0"
6"
6" 2' -
8"
5' - 5"
4"
18" MIN.
3' - 0 11/16"
3' - 0 11/16"
3' - 0 11/16"
3' - 0 11/16"
5' - 4"
3' - 2 1/2"
2' - 1 1/2"
2' - 0"
2' - 0"
11' - 0 1/2"
COPYRIGHT: © 2025 SPE ARCHITECTS
1 2 3 4 5
1 2 3 4 5
A
B
C
D
A
B
C
E
SHEET NUMBER:
SHEET TITLE:
ISSUED:
NO. DATE DESCRIPTION
PROJECT NAME:
REVISIONS:
NO. DATE DESCRIPTION
L a s t P lo tt e d
D
E
PROFESSIONAL STAMP:
CONSULTANT INFORMATION:
1 06/21/26 SCHEMATIC IN PROGRESS
P.O. Box 517 - Kaysville, Utah 84037 info@spe-architect.com 801.298.1368
ARCH I T E C T S
SPE ARCHITECTS
A M
E R
I C
A N
P R
E P
A R
A T
O R
Y A
C A
D E
M Y
W
V C
/3
C A
M P
U S
DESIGNED BY:
CHECKED BY:
PROJECT #:
DRAWN BY:
25-10
ELM/GTE
ELM
ELM
C L
A S
S R
O O
M S
A
U D
I T
O R
I U
M A
D D
I T
I O
N
P H
A S
E
A
R E
A K
FOR REVIEW
ONLY
NOT FOR PERMIT
NOT FOR CONSTRUCTION
/6
/2
:3
:4
P M
A u to d e s k D o c s /2
-1
W
V C
T h e a te r/
W V
C
-A R
C H
R rv t
FLOOR PLAN
LEVEL 1
PHASE 1
AE-103
W
E S
T
S
O U
T H
W E
S T
V A
L L E
Y C
IT
Y
U
T A
H
0 16' 24' 32'8'
PROJECT
NORTH
TR
U E
N O R
TH
1/8" = 1'-0"B1 LEVEL1 - AREA K - FLOOR PLAN
1/8" = 1'-0"B4 LEVEL1 - AREA K - DIMENSIONS
0 16' 24' 32'8'
PROJECT
NORTH
TR
U E
N O R
TH
1 07/07/20
REMINDERS
| Sheets |
| AE-101 - FLOOR PLAN LEVEL 1 OVERALL |
| AE-102 - FLOOR PLAN - LEVELS 2-3 |
| AE-103 - FLOOR PLAN LEVEL 1 PHASE 1 |
| AS-101 - SITE PLAN OVERALL |
| AS-102 - ARCHITECTURAL SITE PLAN |
File details come from the government source that posted it. Updated .