Lubbock_Exhibit_D.pdf

PDF 5 MB Posted

Attached to
LED Lighting, Lubbock Federal Office Building
Solicitation number
47PH1119R0003
Issued by

About this file

Exhibit D

View the file

Other files

File Type Posted
Lubbock__Exhibit_A.pdf PDF
Lubbock_LED_Lighting_SOW_20190716.pdf PDF
Lubbock_Exhibit_D.pdf PDF
Lubbock_Exhibit_C.pdf PDF
Lubbock_RFIs071619.pdf PDF
Amendment_03_SF30.pdf PDF
Lubbock_Exhibit_B.pdf PDF
Lubbock_Exhibit_C.pdf PDF
Lubbock_RFI_s_070119.pdf PDF
Amendment_02_SF30.pdf PDF
Lubbock_Exhibit_A.pdf PDF
Exhibit_B.pdf PDF
Lubbock_Exhibit_E.pdf PDF
Lubbock_LED_Lighting_SOW_20190627.pdf PDF
Amendment_01_SF30.pdf PDF
Lubbock_Exhibit_B_(2).pdf PDF
GSA527.pdf PDF
PBS_Past_Performance_Questionnaire.pdf PDF
47PH1119R0003.pdf PDF
Wage_Determination_TX280.pdf PDF
Lubbock_LED_Lighting_SOW_20190530.pdf PDF
C301_GC_Reps_&_Certs.pdf PDF
SBSA_LPTA_Solicitation.pdf PDF
SBSA_GC_Agreement.pdf PDF
Lubbock_Exhibit_A.pdf PDF
Lubbock_Exhibit_C.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 1 02.09.18

Nova T*

Nova T* Controls This series of classic thin-profile linear-slide dimmers and switches offers the following standard features:

• SquareLawDimming
• Voltagecompensation(notapplicabletoNTCL-250)
• Power-failurememory
• SuperiorRFIsuppression
• Captivelinearslider
• Accessibleair-gapswitch
• Electrostaticdischargetested
• Precisecolormatching
• Heavy-dutycomponentsforsurgeprotectionand

long product life

• 100% factory tested

Product Family Features

• Available for 120 –277 V~ line voltage switching

(sink-onlycontrol)0–10V-LEDdriversandballasts
(powerpacknotrequiredforloadsupto8A)
• Excellentforresidentialorcommercialapplications
• Intuitiveoperation;easytouse
• Slide-to-offandpresetmodelsavailable
• Enclosedheatsinkforaestheticallypleasing

appearance

• Multi-gangalignmentforquickandeasyinstallation
• Fullfamilyofproductsformostlightingsources,plus

matching accessories and wallplates

• Ratedat120V~60Hz,unlessnotedotherwise
• Customproducts(CPN)areavailabletomeet
specificcustomerneeds.PleasecontactLutron
CustomerAssistanceat1.844.LUTRON1(588.7661)
foravailability.

Regulatory Approvals

• UL®Listed
• CSAcertified

• NOM

Colors and Finishes

Whenorderingproductforusewithmetalwallplates,
theproductandwallplatemustbeordered
separately.Seethe“ArchitecturalWallplatesand
Accessories”sectionofVolume 1: Basic Devices
and Single-Space Systems Catalog(P/N367-1746)
fororderingprocedure.Seetabletotherightfor

complete list of metal finishes.

CustomcolormatchingisavailableforallNovaT*
products.Aswatchorsampleisallthatisrequired.Call
customerservicetoarrangeforacolor-matchedcontrol.

Slide-to-Off Controls

Selectlightlevelwithslider;
slidedowntoOFF

Preset Controls

Selectlightlevelwithslider;
pressON/OFF
EngravingisavailableforallNovaT* products.
Engravingschedulesareavailableat

www.lutron.com/engraving or through Customer Assistance at 1.844.LUTRON1 (588.7661).

Available Colors and Finishes Matte Finishes

Toorder,addcolor/finishsuffixcodetomodel
number.Example:NT-600-WH

Code Color Code Color Code Color WH White GR Gray BE Beige

TP Taupe IV IvorySI Sienna
AL Almond LA LightAlmond BR Brown

BL Black

Special Order

Toorder,addcolor/finishsuffixcodetomodel
number.Example:NT-600-BB

Metal Finishes Code Color Code Color

SB SatinBrass BB Bright Brass
BC BrightChrome

Special Metal Finishes Code Color Code Color

QB AntiqueBrassQZ AntiqueBronze
SC SatinChrome SN SatinNickel
BN BrightNickel

Anodized Aluminum Finishes Code Color Code Color Code Color CLA Clear BLA Black BRA Brass

Must be Equal or Better Control 1 Exhibit B

ShaMarCNolen Highlight

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 2 02.09.18

Nova T*

Dimensions Measurements shown as: in (mm)

2.75 (70) 1.31 (33)

4.56(116)
0.30(8)

Small Control Large Control Profile

4.56 (116) 2.75 (70)

Note:Somemodels
asdeepas1.9(48)

Back Views: NT- models

NT-600

NT-1000

NT-1500

NT-2000

Available Controls and Accessories(Summary)
Forspecificuses,capacities,andmodelnumbers,seethefollowingpages.

Controls

Slide-to-Off Dimmers

Small Control

Large Control

Preset Dimmers

Small Control

Large Control

Slide-to-Off Fan-Speed Controls

Small Control

Large Control

Linear-Slide Switches

Small Control

Must be Equal or Better Control 1 Exhibit B

ShaMarCNolen Highlight

ShaMarCNolen Highlight

ShaMarCNolen Highlight

ShaMarCNolen Highlight

ShaMarCNolen Highlight

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 3 02.09.18

Nova T*

(continued on next page…)

Control Specifications Incandescent Dimmers: Slide-to-Off

Small Control Description Maximum Capacity Model Number

Single-pole120V~60Hz 600 W NT-600-XX
Single-pole120V~60Hz 1000 W NT-1000-XX

Large Control Single-pole 120 V~ 60 Hz 1500 W NT-1500-XX

Single-pole 120 V~ 60 Hz 1950 W NT-2000-XX

• TheNT-2000-XXdoesnothaveremovablesidesections;itcanbegangedbutmustbekeptintact.
•TheNT-2000-XXrequiresa2-gangwallbox.

Incandescent Dimmers: Preset

Small Control Description Maximum Capacity Model Number

Single-pole/3-way/4-way120V~60Hz 600 W NT-603P-XX
Single-pole/3-way/4-way120V~60Hz 1000 W NT-1003P-XX

Large Control Single-pole/3-way/4-way 120 V~ 60 Hz 1500 W NT-1503P-XX

• For 3-way or 4-way switching, use NT-3PS-XX (3-way), NT-4PS-XX (4-way), or other mechanical switches.

C•L Dimmers: Slide-to-Off

Small Control Description Maximum Capacity Model Number

DimmableLED/CFL
Single-pole120V~60Hz

250 W NTCL-250-XX

Incandescent/Halogen Single-pole 120 V~ 60 Hz

1000 W

Hi-lume1%2-WireLTELEDdriver
Single-pole120V~60Hz

400 W (maximum of 10 drivers)

Mixedbulbtype
Single-pole120V~60Hz
SeeDerating:Maximum
CapacitiesinMultigang

Installations

Application requirements:

• WhendimmingLEDsorCFLs,onlybulbsmarkedorratedasdimmableandontherecommendedlistmaybeused.
• ForacompletelistofrecommendeddimmableLEDsandCFLspleasevisitwww.lutron.com/dimcflled.For questionscall

1.844.LUTRON1.

• Some dimmable LEDs and CFLs require a minimum number of bulbs for proper operation. For details and the bulb list, visit www.lutron.com/dimcflled

• For LED product selection tool, visit www.lutron.com/ledtool Features:

• Low-endadjustmenttoaccommodateawiderangeofbulbs.
• HEDTTechnology:AdvancedLutrondimmingcircuitrydesignedforcompatibilitywithmosthighefficacylightbulbs.
• NEMASSL-7AType2compliant.

Electronic Low-Voltage (ELV) Dimmers: Slide-to-Off

Small Control Description Maximum Capacity Model Number

Single-pole120V~60Hz 300 W NTELV-300-XX
Single-pole120V~60Hz 600 W NTELV-600-XX
• Maximumcapacityispermittedlampwattage.
• Requiresneutralwireconnection.
• ForlargercapacityELVloads(upto1000W),useNovaT*fluorescentdimmers(NTF-10-XXorNTF-103P-XX)withaPHPM-WBX

interface.

• Minimum Load: 5 W Incandescent / Halogen or 1 ELV transformer. ELV transformer must be loaded per manufacturer’s recommendations.

Must be Equal or Better Control 1 Exhibit B

ShaMarCNolen Highlight

ShaMarCNolen Highlight

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 4 02.09.18

Nova T*

(continued on next page…)

Control Specifications (continued) Magnetic Low-Voltage (MLV) Dimmers: Slide-to-Off

Small Control Description Maximum Capacity Model Number

Single-pole120V~60Hz 600VA/450W NTLV-600-XX
Single-pole277V~60Hz 600VA/450W NTLV-600-277-XX
Single-pole120V~60Hz 1000VA/800W NTLV-1000-XX
Single-pole277V~60Hz 1000VA/800W NTLV-1000-277-XX

Large Control Single-pole 120 V~ 60 Hz 1500 VA / 1200 W NTLV-1500-XX

•Maximumcapacityispermittedlampwattage.
•277V~ models require neutral wire connection.

Magnetic Low-Voltage (MLV) Dimmers: Preset

Small Control Description Maximum Capacity Model Number

Single-pole/3-way/4-way120V~60Hz 600VA/450W NTLV-603P-XX
Single-pole/3-way/4-way120V~60Hz 1000VA/800W NTLV-1003P-XX

Large Control Single-pole/3-way/4-way 120 V~ 60 Hz 1500 VA / 1200 W NTLV-1503P-XX

• For 3-way or 4-way switching, use NT-3PS-XX (3-way), NT-4PS-XX (4-way), or other mechanical switches.

Fluorescent Dimmers for Lutron 3-wire fluorescent ballasts or LED drivers: Slide-to-Off

Small Control Description Maximum Capacity Model Number

Single-pole120V~60Hz 16A NTF-10-XX
Single-pole277V~60Hz 8A NTF-10-277-XX
•UsewithLutron3-wirefluorescentballastsorLEDdriversonly.
•ForLEDloads,pleaseseethe“ReportCards”atwww.lutron.com/ledtool for proper loading of the dimmer.
•Noderatingrequired.
•TodeterminethenumberofballaststhatcanbecontrolledbyNovaT*fluorescentdimmer,dividethecontrolcapacitybytheballast

current.

Fluorescent Dimmers for Lutron 3-wire fluorescent ballasts or LED Drivers: Preset

Small Control Description Maximum Capacity Model Number

Single-pole/3-way120V~60Hz 8A NTF-103P-XX
Single-pole/3-way277V~60Hz 6A NTF-103P-277-XX
•UsewithLutron3-wirefluorescentballastsorLEDdriversonly.
•ForLEDloads,pleaseseethe“ReportCards”atwww.lutron.com/ledtool for proper loading of the dimmer.
•For3-wayor4-wayswitching,useNT-3PS-XX(3-way),NT-4PS-XX(4-way),orothermechanicalswitches.Noderatingrequired.
•TodeterminethenumberofballaststhatcanbecontrolledbyNovaT*fluorescentdimmer,dividethecontrolcapacitybytheballast

current.

Must be Equal or Better Control 1 Exhibit B

ShaMarCNolen Highlight

ShaMarCNolen Highlight

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 5 02.09.18

Nova T*

(continued on next page…)

Control Specifications (continued)

0–10 V- Dimmers for Electronic Ballasts or LED Drivers: Slide-to-Off

Small Control Description Maximum Capacity * Model Number

Single-pole 0 –10 V- 120 – 277 V~ Load 0 –10 V- Sink

NTSTV-DV-XX

8 A 30 mA

•Powerpacknotrequiredforloadsupto8A.MayuseLutronpowerpack(modelPP-DVorPP347H;seeLutronP/N369544)for
higherloadcurrentapplicationsorforClass2installations.
•WorkswithallballastsanddriversthatprovideacurrentsourcecomplianttoIEC60629AnnexE.2,andwhoseinrushcurrentdoes
notexceedNEMA410standardsforelectronicballast/driverloadsof8Asteady-statecurrent.RefertoLEDdriverandballast
manufacturer'sspecificationfor0–10V-sinkcurrents.
•Controlhasahighandlowendtrimtoadjustthe0–10V- output for optimal dimming performance.
*Limitedbywhicheverratingisachievedfirst.

Fluorescent Dimmers for Tu-Wire Electronic Ballasts: Slide-to-Off

Small Control Description Maximum Capacity Model Number

Single-pole120V~60Hz 5A NTFTU-5A-XX
Single-pole277V~60Hz 5A NTFTU-5A-277-XX
•UsewithLutronTu-Wirelinevoltagecontrolelectronicdimmingballastsonly.
•TodeterminethenumberofballaststhatcanbecontrolledbyNovaT*fluorescentdimmer,dividethecontrolcapacitybytheballast

current.

• Compatible with Advance® Mark X® and Sylvania Powersense® ballasts.

Fluorescent Dimmers for Advance® Mark X® VEZ series 277 V~ Ballasts: Preset

Small Control Description Maximum Capacity Model Number

3-way 277 V~ 60 Hz 3 A NTFTU-103P-277-XX-CPW0196

•ForcontrolofpermanentlyinstalledAdvance®MarkX®VEZseries277V~ballastsonly.
•Installonloadsideonly.
•Noderatingrequired.
•TodeterminethenumberofballaststhatcanbecontrolledbyNovaT*fluorescentdimmer,dividethecontrolcapacitybytheballast

current.

Linear-Slide Switches for General Purpose: All Sources and Motor Loads

Small Control Description Maximum Capacity Model Number

Single-pole120/277V~60Hz 20A NT-1PS-XX
3-way120/277V~60Hz 20A NT-3PS-XX
4-way120/277V~60Hz 20A NT-4PS-XX

• No derating required.

Reverse-Phase Electronic Low-Voltage (ELV) Dimmer: Slide-to-Off

Small Control Description Maximum Capacity Model Number

DimmableLED/CFL;
Single-pole120V~60Hz 250W
NTRP-250-XXIncandescent/Halogen
Single-pole120V~60Hz

600 W

ELVwithHalogen
Single-pole120V~60Hz

600 W

•For the best performance, use a bulb that is on the Lutron LED Report Card Tool at www.lutron.com/ledtool For questions call 1.877.DIM.LED8.
•WhendimmingLEDsorCFLs,onlybulbsmarkedorratedasDIMMABLEWITHREVERSE-PHASEORUNIVERSALDIMMERSmaybeused.
•ForrecommendedELVtransformersandcompatibleMR16LEDbulbs,pleaseseeLutronApplicationNote#559at
www.lutron.com/TechnicalDocumentLibrary/048559.pdf.Alwaysfollowthetransformerandbulbmanufacturerinstructionsforallowableloading.
•Notcompatiblewithmagenticlow-voltage(MLV)transformersormagneticLEDtransformers/drivers
•Dimmerisnotcompatiblewithbulbsratedonlyforforward-phasetypedimmers.
•MinimumLoad:1compatibleCFL/LEDbulbor5WIncandescent/Halogenor1ELVtransformer.ELVtransformermustbeloadedperthe

manufacturer’s recommendation.

Must be Equal or Better Control 1 Exhibit B

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 6 02.09.18

Nova T*

Low-voltage Momentary Switch

Small Control Description Maximum Capacity Model Number

Upto10switchesperpowerpack,
24V-/24V~60Hz 1A NTRCS-1-XX
•ForusewithLutrondevices(powerpackandwiredoccupancysensors)only.
•Noderatingrequired.
•NotavailableinAL,LA,orSI.

Fan-Speed Controls: Quiet

Small Control Description Maximum Capacity Model Number

Single-pole, 3-speed 120 V~ 60 Hz 1.5 A NTFSQ-XX

•Forusewithoneceilingpaddlefan.
•Noderatingrequired.

Fan-Speed Controls: Fully Variable

Small Control Description Maximum Capacity Model Number

Single-pole, Adjustable minimum speed 120 V~ 60 Hz 6 A NTFS-6E-XX

Large Control Single-pole, Adjustable minimum speed 120 V~ 60 Hz 12 A NTFS-12E-XX

• For use with one or more ceiling, ventilation, or exhaust fans. Do not mix fan types on same control.

Control Specifications (continued)

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 7 02.09.18

Nova T*

When installing more than one dimmer in the same

wallbox,itmaybenecessarytoremovesomeside
sectionspriortowiring(seediagrambelow).Removalof
sidesectionsmayreducemaximumwattage,asshown
inthechartsbelow.
Mixingbulbtypes(usingacombinationofLED/CFLand
incandescent/halogenbulbs)willalsoaffectthe
maximumratings,asshowninthechartsbelow.
Example:Ifonesetofsidesectionsisremovedandyou
haveeight9WLEDbulbsinstalled(TotalLED
Wattage=72W),youmayaddupto500 Wof
incandescentorhalogenlightingwiththeC•L
controlor300WwiththeReverse-Phasecontrol.

Derating: Maximum Capacities in Multigang Installations*

Eachcontrolhasinside
sectionsremoved
Middlecontrolhastwoside
sectionsremoved

Do not remove outside sections (shaded areas below)

* For more information on multigang installations, visit www.lutron.com/en-US/Service-Support/Pages/Technical/InstallationInstructions/Ganging-Derating/ GangingDerating.aspx

(continued on next page…)

Reverse-Phase Electronic Low-Voltage (ELV) Controls

Maximum Allowable Incandescent/Halogen Wattage + Total LED / CFL Wattage Installed (Wattage per bulb × number of bulbs)

600 W 500W 400W + 0 W
500W 400W 300 W + 1W–40W
400W 300 W 200 W + 41W–80W
300 W 200 W 100 W + 81W–120W
200 W 100 W 50W + 121W–160W
100 W 50W 0 W + 161W–200W
0 W 0 W 0 W + 201W–250W
•NoderatingisrequiredformultiganginstallationsifonlyLEDbulbsareusedorifnofinsarebroken.

LED

DELLFCA

CFL

AFC

Single Units

Fullcapacity.
Nosidesections

removed

End Units One side section removed

Middle Units Two side sections removed

Incandescent Controls

600 W 500W 300 W
1000 W 900 W 700W
1500W 1250W 1000 W
1950W — —
•NT-2000-XXcontrols(for1950Wcapacity)mustbeganged
withoutremovingsidesections.

C•L Controls

Maximum Allowable Incandescent/Halogen Wattage + Total LED / CFL Wattage Installed (Wattage per bulb × number of bulbs)

1000 W 800 W 600 W + 0 W

800 W 600 W 500W + 1W–40W
600 W 500W 400W + 41W–80W
500W 400W 300 W + 81W–120W
400W 300 W 200 W + 121W–160W
300 W 200 W 100 W + 161W–200W
0 W 0 W 0 W + 201W–250W
•NoderatingisrequiredformultiganginstallationsifonlyLEDbulbsareusedorifnofinsarebroken.

LED

DELLFCA

CFL

AFC

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 8 02.09.18

Nova T*

Derating: Maximum Capacities in Multigang Installations* (continued) Single Units

Fullcapacity.
Nosidesections

removed

End Units One side section removed

Middle Units Two side sections removed

Electronic Low-Voltage (ELV) Controls

300 W 300 W 250W
600 W 500W 400W
•PermittedlampwattageforELVcontrols.

Magnetic Low-Voltage (MLV) Controls

600VA/450W 500VA/400W 300VA/250W
1000VA/800W 900VA/750W 700VA/500W
1500VA/1200W 1250VA/1000W 1000VA/800W
•PermittedlampwattageforMLVcontrols.

Fluorescent 3-Wire Ballast or LED Driver Controls

6A Noderatingrequired
8A Noderatingrequired
16A Noderatingrequired

Fluorescent Tu-Wire Controls

3A Noderatingrequired
5A 4A 3.3A

0–10 V- Electronic Ballast or LED Driver Controls

Load 0–10 V- Sink No derating required

8 A 30 mA

Quiet Fan-Speed Controls

1.5 A No derating required

Fully Variable Fan-Speed Controls

6A 4.2A 2.5A
12A 10A 8.3A

* For more information on multigang installations, visit www.lutron.com/en-US/Service-Support/Pages/Technical/InstallationInstructions/Ganging-Derating/ GangingDerating.aspx

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 9 02.09.18

Nova T*

Wiring Diagrams: Single Location

Single-Pole Control

Black1Black1 Line / Hot

Neutral

Green2 Load

Control

Models:

•NT-600-XX
•NT-1000-XX
•NT-1500-XX
•NT-2000-XX
•NTCL-250-XX
•NTLV-600-XX
•NTLV-1000-XX
•NTLV-1500-XX
•NT-1PS-XX
•NTFSQ-XX

Single-Pole Control with Neutral

RedorYellowBlack
Line/

Hot

Neutral

White Green

Load

Control

Models:

•NTELV-300-XX**
•NTELV-600-XX**
•NTLV-600-277-XX
•NTLV-1000-277-XX

** Use NTELV- models with 120 V~ only

3-Way Control

Models:

•NT-603P-XX
•NT-1003P-XX
•NT-1503P-XX
•NTLV-603P-XX
•NTLV-1003P-XX
•NTLV-1503P-XX
•NT-3PS-XX

Red1Black3 Line / Hot

Neutral

Green2 Load

Control Red (capped)1

Fan Control

Models:

•NTFS-6E-XX
•NTFS-12E-XX

** Switched full-voltage only

RedBlack Line / Hot

Neutral

Green

Load (fan)

Control Yellow** (capped)

RedBlack Line / Hot

Neutral

Green

Load (fan)

Load (incandescent)**

Fan/Light Control

Models:

•NTFS-6E-XX
•NTFS-12E-XX

** Switched full-voltage only

Control Yellow

Key

Ground

Wire connector

1 Wire or brass/ gold screw terminal*

2 Wire or green screw terminal*

3Wireorcopper/
blackscrew

terminal*

*Dimmershave
wires;switches
havescrew

terminals

P

NP

P

NP

• NTRP-250-XX

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 10 02.09.18

Nova T*

Wiring Diagrams: Multi-Location

3-Way Control Line Side

Red1

Red1Black Red

Red

Black3 Line / Hot

Neutral

Green Green2 Load

3-Way Dimmer

3-Way Switch

4-Way Control Line Side

Red

Red Red1

Red1

Red1

Red1Black Black3

Black3

Black3 Line / Hot

Neutral

Green Green2 Green2 Load

3-Way Dimmer

4-Way Switch

3-Way Switch

Load Side

Red

Red1 Red1

Red1 Red1

Red

Black3 Black Line / Hot

Neutral

Green2 Green2 Green Load

3-Way Switch

4-Way Switch

3-Way Dimmer

Load Side

Red1

Red1

Black3 Black Line / Hot

Neutral

Green2 Green Load

3-Way Switch

3-Way Dimmer

Models:

•NT-603P-XX
•NT-1003P-XX
•NT-1503P-XX
•NTLV-603P-XX
•NTLV-1003P-XX
•NTLV-1503P-XX
•NT-3PS-XX
•NT-4PS-XX

Models:

•NT-603P-XX
•NT-1003P-XX
•NT-1503P-XX
•NTLV-603P-XX
•NTLV-1003P-XX
•NTLV-1503P-XX

• NT-3PS-XX

Black3

Black3

Red

Red

Key

Ground

Wire connector

1 Wire or brass/ gold screw terminal*

2 Wire or green screw terminal*

3Wireorcopper/
blackscrew

terminal*

*Dimmershave
wires;switches
havescrew

terminals

P

NP

P

NP

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 11 02.09.18

Nova T*

Wiring Diagrams: NTF- Controls

3-Way Control Single-Pole

Single-Pole Control

Models:

•NTF-10-XX
•NTF-10-277-XX

Load Side

Models:

•NTF-103P-XX
•NTF-103P-277-XX

Blue Red

Violet or Blue Yellow or OrangeRed1

Red1 Black

Black

Whiteb

Whiteb

Orange or Browna

Orange or Browna

To additional ballasts

Black3 Line / Hot

Neutral

Dimming Ballast

Dimming Ballast

WhiteGreen2 Green

3-Way Switch

3-Way Dimmer

Black Red

Yellow or Orange

Black

Black

Orange or Browna

Orange or Browna

Whiteb

Whiteb

To additional ballasts

Line / Hot

Neutral

Dimming Ballast

Dimming Ballast White

Green

Dimmer

Blue Red

Violet or Blue (capped)

Yellow or Orange

Black

Black

Whiteb

Whiteb

Orange or Browna

Orange or Browna

To additional ballasts

Line / Hot

Neutral

Dimming Ballast

Dimming Ballast

White

Green

3-Way Dimmer

Key

Ground

Wire connector

Typical 4-wire connection

aYellow/Blueor
Yellow/Greenwire

when used with magnetic dimming ballasts b Must use lamp disconnect sockets with magnetic dimming ballasts

1 Wire or brass/ gold screw terminal*

2 Wire or green screw terminal*

3Wireorcopper/
blackscrew

terminal*

*Dimmershave
wires;switches
havescrew

terminals

P

NP

P

NP

P

NP

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 12 02.09.18

Nova T*

Wiring Diagrams: NTFTU- Controls

Model:

• NTFTU-103P-277-XX-CPW0196

3-Way Control Single-Pole

Single-Pole Control

Model:

• NTFTU-5A-XX

Blue

Blue (capped)

Yellow Black Line / Hot

Neutral

Dimming Ballast

White

Green

Dimmer

Black Black Line / Hot

Neutral

Dimming Ballast

White

Green or Bare

Dimmer

Load Side

Blue

Blue

YellowBlack3 Red1

Red1

Line / Hot

Neutral

Dimming Ballast

White

Green2 Green

3-Way Switch Dimmer

Key

Ground

Wire connector

1 Wire or brass/ gold screw terminal*

2 Wire or green screw terminal*

3Wireorcopper/
blackscrew

terminal*

*Dimmershave
wires;switches
havescrew

terminals

P

NP

P

NP

Model:

• NTFTU-5A-277-XX

Line / Hot Black Red

Green or Bare

White

Dimming Ballast

Dimmer

Neutral

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 13 02.09.18

Nova T*

Wiring Diagrams: NTSTV- Controls

•Thetotal0–10V-controlsignalwiringforthiscontrolshouldnotexceed500ft(152.4m).
•Donotusewiresmallerthan20AWG(0.75mm2).
•ForClass1installations,0–10V-wiresmustberuninconduitorapprovedcableperNEC®orlocaljurisdiction.
•ForClass2installations,conduitistypicallynotrequired(localcodemayapply).
•Forapplicationwithexcessiveelectricalnoise,0–10V-wiresshouldberuninseparateconduitfromthemains.

Class 1 Installation

Black

White

White

Violet (+)

Violet (+) Violet (+)

Black

Red Black

Gray (–)

Gray (–) Gray (–)

To additional ballasts

Line / Hot

Neutral

0–10 V-

DimmingBallast
orLEDDriver

0–10 V-

DimmingBallast
orLEDDriver

Green

Control

Class1
0–10V-Control
SignalWiresa

120 – 277 V~

Model:

• NTSTV-DV-XX

Maximum Capacity *

Load 0–10 V- Sink 8 A 30 mA

* Whichever comes first.

Class 2 Installation ON/OFF control using Power Pack (PP-DV or PP-347H)

Redb

Black Black

Red

Blue

White

Redb

Red

Black Black (capped)

White

White

Violet (+)

Violet (+) Violet (+)

Black

Black

Gray (–)

Gray (–) Gray (–)

To additional ballasts

Line / Hot

Neutral

0–10 V-

DimmingBallast
orLEDDriver

0–10 V-

DimmingBallast
orLEDDriver

Greenc

Control

Power Pack

Class2
0–10V-Control
SignalWiresa
IECPELV/NEC®Class2wiring:
20AWG(0.75mm2)a

Model:

• NTSTV-DV-XX

Maximum Capacity

Load 0–10 V- Sink ** 30 mA

**SeePP- and UPP-Series Power Packs
specsubmittal,LutronP/N369544

Key

Ground

Wire connector

Wire connector

Typical 4-wire connection

aDoNOTconnect
tolinevoltage
b18AWG
(1.0 mm2)red

wires are interchangeable.

Connect to either line or load side

cGreenwiremay
becappedfor
Class2
installationsONLY

P

NP

P

NP

P

NP

P

NP

Notice

• Lutron is not liable for damage due to miswiring 0 –10 V-

controlsignalwireswithlinevoltage.
•DonotrunClass 2wiresandlinevoltageconductorstogether

in the same conduit.

Job Number:

Model Numbers:

Dimmers, Switches, and Accessories Wallbox Controls

369616q 14 02.09.18

Nova T*

Wiring Diagrams: NTCL- Controls

Hi-lume 1% 2-Wire LTE LED Driver Installation

Model:

• NTCL-250-XX

Neutral

Line/
Hot DimmedHot(Black)

Neutral (White)

Ground (Green)a

+V (Red)b

–V (Black/White)b Grounda

Grounda

NTCL-250

Dimmer

Hi-lume 1% 2-Wire LED

Driver

LED

Light Engine

Key

Ground

Wire connector

aEnclosureand
junctionboxmust
begroundedin

accordance with local and national electrical codes.

Groundprovided
bygroundingof
junctionboxorby

using the green ground wire connection

bFormaximum
driver-to-LEDlight

engine wire length, see Hi-lume 1% 2-Wire LED Driver (P/N 369543)

P

NP

P

NP

Lutron,)Lutron,C•L,Hi-lume,NovaT*,andTu-WirearetrademarksofLutronElectronicsCo.,Inc.,registeredintheU.S.andothercountries.
NECisaregisteredtrademarkofNationalFireProtectionAssociation,Quincy,Massachusetts.
ULisatrademarkofULLLC.
AdvanceandMarkXareregisteredtrademarksofPhilipsCorporation.
PowersenseisaregisteredtrademarkofSylvaniaCorporation.

PEP ecopassport No LGRP-00259-V01.01-EN Page 1 / 5

LEGRAND’S ENVIRONMENTAL COMMITMENTS

• Incorporate environmental management into our industrial sites Of all Legrand sites worldwide, over 85% are ISO 14001 certified (sites belonging to Legrand for more than five years).

• Offer our customers environmentally friendly solutions Develop innovative solutions to help our customers design more energy efficient, better managed and more environmentally friendly installations.

• Involve the environment in product design Reduce the environmental impact of products over their whole life cycle.

Provide our customers with all relevant information (composition, consumption, end of life, etc.).

Product Environmental Profile Wattstopper® - Passive Infrared Fixture Integrated Outdoor Sensor operating at 277 V

Legrand North America Wattstopper Inc.

2234 Rutherford Drive Carlsbad, CA 92008

1.877.BY.LEGRAND (295.3472)

www.legrand.us

REFERENCE PRODUCT

Function Multi-level light control based on occupancy and daylight detection in an area between 40 ft and 100 ft in diameter for outdoor environements for a period of 10 years.

Reference Product

Part Number: FSP-211 Passive Infrared Fixture Integrated Outdoor Sensor, operating at 277 V

The company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in the document are for guidance and cannot be held binding on the company.

COMPANY OVERVIEW

• Designed to Be Better – Our Commitment to Sustainability At Legrand®, our sustainability commitment translates into greater benefits and tangible value for our customers, business partners, employees, and the broader community.

• Better Performance We provide building solutions to meet many building performance goals from sustainability and energy efficiency to productivity and occupant well being. The right choice in network and electrical infrastructure can play a key role in many facets of building performance. Our products help ensure electrical safety. They offer choice and flexibility in space design. They are designed to reduce installation time and material waste on site. Because we know buildings consume a great deal of energy, we offer a range of products and solutions that reduce energy consumption from lighting to plug load to data centers.

• Better Solutions We offer a wide range of innovative solutions for the building, while constantly evolving our design and development processes to improve the environmental profile of our products. Through active monitoring and research, we serve as an expert resource for market trends and building and product performance standards to keep our customers at the top of their game.

• Better Operations We focus on operational excellence because we believe optimizing the way we manage energy, water and waste is not only good for the environment, it’s good for business. As part of the Department of Energy’s Better Building, Better Plants Challenge (BBBP) Legrand has reduced its energy intensity by over 30% across 14 sites in the United States in just three years. Integrating sustainability into the way we run our operations makes us more competitive – and a better business partner.

For information on Legrand PEP’s and our sustainability initiatives, scan the QR code to be brought to our High Performance Buildings page.

Must Be Equal or Better Control 2 Exhibit B

PEP ecopassport No LGRP-00259-V01.01-EN Page 2 / 5

Legrand North America Wattstopper Inc.

2234 Rutherford Drive Carlsbad, CA 92008

1.877.BY.LEGRAND (295.3472)

www.legrand.us

Product Environmental Profile Wattstopper® - Passive Infrared Fixture Integrated Outdoor Sensor operating at 277 V

CONSTITUENT MATERIALS

This Reference Product contains no substances prohibited by the regulations applicable at the time of its introduction to the market.

Total weight of Reference Product (with unit packaging) 107 g

Plastics as % of weight Metals as % of weight Other as % of weight

Polycarbonate (PC) 26.1% Steel 1.0% Printed Circuit Boards 42.1%

Ethylene-Propylene-Diene Mono-mer (EPDM)

1.0%

Packaging as % of weight

Cardboard 21.4%

Paper 4.9%

Polyethylene 3.5%

Total plastics 27.1% Total metals 1.0% Total other and packaging 71.9%

Estimated recycled material content: 18% of weight.

It respects the restrictions on use of hazardous substances as defined in the RoHS directive 2011/65/EC.

PRODUCTS CONCERNED

The environmental data is representative of the following products operating at 277 V:

FSP-211-x, FSP-211B-x, FSP-221B-x, and FSP-212-x

Where “-x” is any combination of numbers or letters that specify:

- Made in USA

- Mounting style

- Lenses

- Color

DISTRIBUTION

Products are distributed from logistics centers located to optimize transport efficiency using EPA SmartWay® certified carriers to reduce greenhouse gases emissions. Information on the distance of distribution is not available so the PCR hypothesis for “Intercontinental transport”, 2175 miles (3500 km) by heavy truck, was used. This represents transportation of the Reference Product from our warehouse to the local point of distribution in the North American market.

MANUFACTURING

The Reference Product comes from sites that have received ISO 14001 certification.

PEP ecopassport No LGRP-00259-V01.01-EN Page 3 / 5

Wattstopper Inc.

2234 Rutherford Drive Carlsbad, CA 92008

1.877.BY.LEGRAND (295.3472)

www.legrand.us

Product Environmental Profile Wattstopper® - Passive Infrared Fixture Integrated Outdoor Sensor operating at 277 V

Manufacturing Primary packaging taken into account, including pallet. As required by the PEP ecopassport program, all transport for the manufacturing of the Reference Product, including materials and components, has been taken into account. Inter-national transport, as defined by the PCR, was used to take into account transportation from the production site to the final distribution center. The waste generated during manufacturing phase has been taken into account.

Distribution Transport between the last distribution center and an average delivery to the sales area. The default scenario mod-elled maximizes the environmental impact.

Installation The end of life of the packaging (29.2 g) is taken into account at this phase. Transport of packaging to end of life treatment.

Use • Under normal conditions of use, this type of product requires no servicing or maintenance.

• No consumables are necessary to use this type of product.

• Product category: Other equipment - Category 2, Active product.

• Use scenario: Active sensing mode (0.331 W) in continuous operation (100% of the time) for 10 years. Wattage is based on operation at 277 V. This modeling duration does not constitute a minimum durability requirement.

• Energy model: Electricity (US) - 2009.

End of life The default end of life scenario modeled maximizes the environmental impact.

Software used EIME V5 and its database “CODDE-2015-04” and the indicators defined in the PCR ed 3 in alignment with the EN15804 standard

ENVIRONMENTAL IMPACTS

The evaluation of environmental impacts examines the stages of the Reference Product life cycle: manufacturing, distribution, installation, use, and end of life. It is representative of products marketed and used in North America.

The following modelling elements were taken into account:

INSTALLATION

No required components, products, parts, nor processes for installation. No electricity is required for installing the Reference Product.

USE

Servicing and maintenance:

Under normal conditions of use, this type of product requires no servicing or maintenance.

Consumable:

No consumables are necessary to use this type of product.

END OF LIFE

• Hazardous waste* contained in the product: no hazardous waste (*) Hazardous waste as defined by European Commission decision 2000/532/EC.

• Recycling rate:

Calculated using the method described in the IEC/TR 62635 technical report, the recyclability rate of the Reference Product without packaging is estimated as 12%. This value is based on data collected from a technological channel using industrial procedures. It does not pre-validate the effective use of this channel for end-of-life electrical and electronic products.

Separated into: (% mass of Reference Product without packaging)

- plastic materials (excluding packaging): 1%

- metal materials (excluding packaging): 1%

- other materials (excluding packaging) : 10%

Recycling rate of packaging (all types of materials): 60% (% mass of packaging)

PEP ecopassport No LGRP-00259-V01.01-EN Page 4 / 5

Wattstopper Inc.

2234 Rutherford Drive Carlsbad, CA 92008

1.877.BY.LEGRAND (295.3472)

www.legrand.us

Product Environmental Profile Wattstopper® - Passive Infrared Fixture Integrated Outdoor Sensor operating at 277 V

The environmental impact of the Reference Product occurs predominantly during the manufacturing and use phases.

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

GWP ODP A EP POCP ADPe PE FW ADPf WP AP

% Environmental Impact per Life Cycle Stage of Reference Product

Manufacturing Distribution Installation Use End of life

ENVIRONMENTAL IMPACTS (continued)

Total for Life cycle

Raw material and manufacturing Distribution Installation Use End of life

Global warming (GWP) 2.72E+01 kg CO2 eq. 7.01E+00 26% 1.87E-02 <1% 2.38E-02 <1% 2.01E+01 74% 8.01E-02 <1%

Ozone depletion (ODP) 1.28E-06 kg CFC-11 eq. 9.14E-07 71% 3.78E-11 <1% 8.94E-11 <1% 3.64E-07 28% 2.57E-09 <1%

Acidification of soil and water (A) 2.77E-02 kg SO2 eq. 8.26E-03 30% 8.38E-05 <1% 1.70E-05 <1% 1.92E-02 70% 6.53E-05 <1%

Water eutrophication (EP) 7.53E-03 kg PO4

3- eq. 2.35E-03 31% 1.93E-05 <1% 2.06E-05 <1% 5.11E-03 68% 2.83E-05 <1%

Photochemical ozone creation (POCP) 4.07E-03 kg C2H4 eq. 9.78E-04 24% 5.96E-06 <1% 5.43E-06 <1% 3.08E-03 76% 5.00E-06 <1%

Depletion of abiotic resources - elements (ADPe)

1.82E-03 kg Sb eq. 1.82E-03 100% 7.47E-10 <1% 2.25E-10 <1% 1.97E-07 0% 5.13E-10 <1%

Total use of primary energy (PE) 4.38E+02 MJ 9.34E+01 21% 2.64E-01 <1% 5.41E-02 <1% 3.44E+02 79% 2.71E-01 <1%

Net use of fresh water (FW) 7.58E-02 m3 4.03E-02 53% 1.67E-06 <1% 7.93E-06 <1% 3.55E-02 47% 3.72E-05 <1%

Depletion of abiotic resources – fossil fuels (ADPf)

3.96E+02 MJ 7.76E+01 20% 2.62E-01 <1% 5.00E-02 <1% 3.18E+02 80% 2.38E-01 <1%

Water pollution (WP) 1.72E+03 m3 7.27E+02 42% 3.07E+00 <1% 3.73E-01 <1% 9.90E+02 57% 3.89E+00 <1%

Air pollution (AP) 2.31E+03 m3 5.98E+02 26% 7.65E-01 <1% 7.05E-01 <1% 1.71E+03 74% 1.52E+00 <1%

The values of the 27 impacts defined in the PCR-ed3-EN-2015 04 02 are available in the digital database of pep-ecopassport.org website.

The environmental impacts of the Reference Product are representative of the products covered by the PEP, which therefore constitute a homogeneous environmental family.

PEP ecopassport No LGRP-00259-V01.01-EN Page 5 / 5

Wattstopper Inc.

2234 Rutherford Drive Carlsbad, CA 92008

1.877.BY.LEGRAND (295.3472)

www.legrand.us

Product Environmental Profile Wattstopper® - Passive Infrared Fixture Integrated Outdoor Sensor operating at 277 V

For products other than the Reference Product, the environmental impacts can be determined for each life cycle phase by multiplying the Reference Product impacts by the factors listed below. Values are generally consistent within a life cycle phase for each product.

Factor Ratio to calculate factor A Wattage of product energy use / Wattage of reference product energy use B Mass of product without packaging / Mass of reference product without packaging C Mass of product packaging / Mass of reference product packaging D Total mass of product with packaging / Total mass of reference product with packaging

ENVIRONMENTAL IMPACTS (continued)

Registration number: LGRP-00259-V01.01-EN Drafting rules: “PCR-ed3-EN-2015 04” Supplemented by “PSR-0005-ed2-EN-2016 03 29”

Verifier’s accreditation number: VH08 Information and reference documents: www.pep-ecopassport.org

Date of issue: 09-2016 Validity period: 5 years

Independent verification of the declaration and data, in compliance with ISO 14025:2010 Internal External

The PCR Review was conducted by a panel of experts chaired by Philippe Osset (SOLINNEN).

The elements of the present PEP cannot be compared with elements from another program.

Document in compliance with ISO 14025:2010: “Environmental labels and declarations - Type III environmental declarations”

In compliance with ISO 14040:2006: “Environmental management – LCA – Principles and framework” In compliance with ISO 14044:2006: “Environmental management – LCA – Requirements and guidelines” In alignment with EN 15804:2012+A1:2013: “Sustainability of construction works - EPD’s - Core rules for the product category of construction products”

Part Number Manufacturing Distribution Installation Use End of Life

FSP-211B

FSP-221B 0.6*B D C A D

FSP-212 B D C A B

FEATURES & BENEFITS

SPECIFICATIONS

WIRELESS HANDHELD CONFIGURATION

TOOL

FSIR100 | Wattstopper

The FSIR100 Wireless IR Configuration Tool is a handheld tool for remote configuration of IRenabled fixture integrated sensors. The tool enables device modifications via push button, without ladders or tools, and stores up to six sensor parameter profiles to speed configuration of multiple sensors.

Enables fast ladderfree setup and maintenance Easytoread OLED screen Allows precise configuration with greater granularity than dip switches or trimpots 2way IR communication for data upload, download, confirmation and storage Easytouse navigation pad Configures IRenabled fixture sensors including selected HBP and FSP models

MODELS

Product Number: FSIR100

GENERAL INFO

Typical Applications: Parking Facilities, Gas Stations, Pedestrian Pathways, Warehouses Type: Remote

LISTING AGENCIES/THIRD PARTY CERTIFICATIONS

RoHS: Yes

A:
B:
C:
D:
E:
F:
G: 1
H: 2
I: 3
J: 4
K: 5
L: 6
M: 7
N: 8
O: 9
P: 10
Q: 11
R: 12
S: 13
T: 14