RFI OVERALL FURN PLAN REV (3.20.20) signed.pdf
PDF 459 KB Posted
- Attached to
- DOT-FMC SA Alterations, Sam Nunn AFC
- Solicitation number
- 47PE0220R0015
About this file
This document announces a Request for Proposal for design and construction services for alterations to the U.S. Department of Transportation Federal Motor Carrier Safety Administration facilities located in Atlanta, Georgia. Work will include demolition, installation of new and reused partitions, glass front partitions, fire rated partitions, offices, conference rooms, break rooms, LAN rooms and associated areas. Additional work comprises new and reused doors and hardware, reuse of undamaged ceiling tiles and grid, new and reused light fixtures, new finishes, HVAC, plumbing, sprinkler and fire alarm system modifications. Infrastructure will also be provided for new power, voice, data, audiovisual systems and controlled access/security equipment. This procurement is set aside for total small business women owned firms. The estimated project magnitude is between $500,000 to $1,000,000. Proposals are due by April 3, 2020. The pre-bid site visit will take place on March 11, 2020. The solicitation and questions will be posted on FBO.gov. Award will be made using LPTA procedures to the firm offering best value to the Government.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OPTION G - REVISED 3.20.20
PRELIMINARY TEST FIT AND CONCEPT
FURNITURE PLAN ONLY.
PLAN IS NOT INTENDED FOR CONSTRUCTION.
SPACE HAS NOT BEEN FIELD VERIFIED FOR ACCURACY.
DOT'S IT, DATA, TEL AND ELECTRICAL REQUIREMENTS TO
BE DETERMINED BY DESIGN BUILD CONTRACTOR.
LAYOUT IS PENDING LIFE-SAFETY REVIEW.
RECEPTION /
MAIN ENTRANCE
REGIONAL
FIELD
ADMIN.
COPIER
FI
LE
S /S
TO
R A G
E
M
AR
KE
R B
OA
RD
FI
LE
S /S
TO
R A G
E
FI
LE
S /S
TO
R A G
E
CONF
OFC
LAN
212223
24 25 26 27
CRITICAL
DIMENSION
M.W.
REF. COFFEE
FILES/STORAGE
42"H HIGH STORAGE W/COLLATING
SURFACE ABOVE
COMBINATION
LAN & LAN
WORKROOM
VTC
BUFFET HT
CREDENZA
PO4
BREAK
AREA
MEETING RM - CONF CONFIGURATION
MULTI-PURPOSE
M
AR
KE
R B
OA
RD
CONF
VTC
BUFFET HT
CREDENZA
MEETING RM - TRAINING CONFIGURATION
WT2465
TYP. FLOOR TO CEILING
GLASS ALONG
BUILDING PERIMETER
32"PIV
OFC
OFC
OFC
OFC
OFC
EX 77X21
TABLE FOR
EQUIPTMENT.
OUTLET TYPES
AND HEIGHTS
TBD.
APROX.
36 SF
181716
OFC
PO2
PO3
3H-LAT 3H-LAT
3H-LAT
3H-LAT
3H-LAT
TYPICAL MAIL
STATION-B
EX
T7
3H-LAT
NO
T A
VA
ILA
BL
E O
N
GS
A-
BP
A
NON-TYP WS DUE TO
LOW PANEL RQRD AT
WINDOW.
J
J
J
J
MA2
WS4-DOT
MA2
WS4-DOT
MA2
WS4-DOT
MA2
WS4-DOT
MA2
WS4-DOT
MA2
WS4-DOT
MA2
WS4-DOT
MA2
CAPSTD
CAPSTDTITLECAPALIAS1CAPALIAS2CAPALIAS3CAPBLDGCAPFLOORCAPDEPTCAPPERSONCAPSTDTYPE
CUSTOMER TO ADVISE IF
PANELS ALONG WINDOWS
SHOULD BE LOWERED TO 42H
PRIOR TO ORDER ENTRY.
RECOMMENDED LOCATION FOR
SYSTEMS TO BE HARD-WIRED TO
BLDG POWER SOURCE ON WALL.
J
WALL BLOCKING
REQUIREMENTS FOR
WALL DISPLAYS, OUTLETS
TYPES & HEIGHTS TO
BE CORDINATED
BY IT VENDOR AND
CONTRACTOR.
WT2465
WT2465
WT2465
WT2465
WT2465
WT2465
PO2
PO2
PO2
PO2
OUTLETS NOTED
ARE RECOMMENDED
LOCATIONS ONLY.
CONTRACTOR TO CONFIRM
CUSTOMER'S SPECIFIC
DATA/IT/ELEC/TEL REQUIREMENTS.
WALL BLOCKING
REQUIREMENTS FOR
WALL DISPLAYS, OUTLETS
TYPES & HEIGHTS TO
BE CORDINATED
BY IT VENDOR AND
CONTRACTOR.
OUTLETS AND HEIGHTS
TO BE DETERMINED.
WALL BLOCKING REQUIREMENTS FOR WALL DISPLAYS, OUTLETS TYPES
& HEIGHTS TO BE CORDINATED BY IT VENDOR AND CONTRACTOR.
BCH-1 (30X54)
BCH-1 (30X54)
CU
ST
OM
ER
TO
PR
OV
ID
E
IF
RE
QU
IRE
D
AH
AH
AH
AH 4629
AH 4629
OPTION 'A' LAYOUT
PENDING
SECURE LOCKING
SPECIFICATIONS
AVAILABLE.
PIV BCH-1 (30X54)
OPTION 'B' LAYOUT
PENDING
SECURE LOCKING
SPECIFICATIONS
AVAILABLE.
PP
POWER POLE
REQUIRED TO HARD-WIRE
THIS CLUSTER OF
WORKSTATIONS.
FLOOR CORES ARE NOT POSSIBLE
IN THIS ROOM.WALL OUTLETS TO BE PROVIDED
ON ALL 4 WALLS (INCLUDING PERIMETER
WINDOW WALL)
IF POSSIBLE.
HUDDLE
RM
11 x 17 sheet edge (no print)
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
DOT FMCSA SSC- ATLANTA - AFC 3RD FL. SUITE 3M40/M55 PLAN IS NOT FOR CONSTRUCTION
FURNITURE CONCEPT PLAN ONLY
REVISED 3.20.20
LIFE SAFETY REVIEW REQUIRED
GENERIC OFFICE FURNITURE LAYOUT ONLY
GSA PBS REGION 4 DESIGN AND CONSTRUCTION
CONCEPTUAL FURNITURE PLAN ONLY - REV 3.20.20
SCALE: TO FIT
Approved change of the combination LAN & LAN workroom (13) and workstations 14 &15.
3/26/2020
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
CUST.
AutoCAD SHX Text E0325
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text
STAIR
AutoCAD SHX Text #4
AutoCAD SHX Text 3M55
AutoCAD SHX Text 3M40
AutoCAD SHX Text 3M60
AutoCAD SHX Text
MEN
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
PASS-THRU WINDOW
AutoCAD SHX Text
OCT-2
AutoCAD SHX Text
CAPPN
AutoCAD SHX Text
CAPMG
AutoCAD SHX Text
CAPMC
AutoCAD SHX Text
CAPQT
AutoCAD SHX Text
CAPDH
AutoCAD SHX Text
CAPGC
AutoCAD SHX Text
CAPPN
AutoCAD SHX Text
CAPMG
AutoCAD SHX Text
CAPMC
AutoCAD SHX Text
CAPQT
AutoCAD SHX Text
CAPDH
AutoCAD SHX Text
CAPGC
AutoCAD SHX Text
CFT-1-30SQ
AutoCAD SHX Text
CAPPN
AutoCAD SHX Text
CAPMG
AutoCAD SHX Text
CAPMC
AutoCAD SHX Text
CAPQT
AutoCAD SHX Text
CAPDH
AutoCAD SHX Text
CAPGC
AutoCAD SHX Text
CFT-1-30SQ
AutoCAD SHX Text
CHANGE OF FLOOR FINISH
| Sheets and Views |
| OVERALL PLAN LARGE OFC - 11x17-G |
File details come from the government source that posted it. Updated .