This solicitation package describes requirements for a construction renovation project. The General Services Administration seeks a contractor to renovate approximately 2,700 square feet of space on the fourth floor of the Kenneth B. Keating Federal Building and U.S. Courthouse in Rochester, New York. Renovations will include elements to support the work functions of the U.S. Trustees such as a reception area, workstations, enclosed offices, storage areas, a mail room, break room, and conference room. Base interior work includes hazardous material abatement, walls, doors, casework, flooring, plumbing, electrical, fire protection and mechanical systems. Additional requirements include technology, data and security infrastructure. The total project cost is estimated between $500,000 and $1,000,000. The solicitation is set aside for small businesses with a size standard of $38.5 million. The required construction completion date is approximately 192 calendar days after notice to proceed. Responses are due no earlier than 15 days after posting in FedBizOpps. The contracting officer is James Berring of the General Services Administration and can be reached at james.berring@gsa.gov.
View the file
Other files for this federal contract opportunity
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTCHED STUD
TRACK, MIN 20 GA.
V A
R
IE
S S
E E
D E
T A
IL
S
PROVIDE BLOCKING WHERE
FASTENERS ARE LOCATED AT
WALL MOUNTED ITEMS
(TYPICAL). SECURE BLOCKING
W/ 2 SCREWS PER STUD
SCHEDULED
PARTITION FRAMING
SCHEDULED
PARTITION
SHEATHING
2 x 6 NOMINAL
BLOCKING
V A
R
IE
S S
E E
D E
T A
IL
S
PROVIDE WOOD BLOCKING WHERE
FASTENERS ARE LOCATED AT
WALL MOUNTED ITEMS (TYPICAL).
SECURE BLOCKING W/ 3 SCREWS
PER STUD
SCHEDULED
PARTITION FRAMING
SCHEDULED
PARTITION
SHEATHING
5/8"
/2
WOOD CHAIR RAIL - STAIN (STN)
ACOUSTIC INSULATION
EXISTING STEEL
RUNNER AND STUDS
(1) LAYER 5/8" GWB EACH
SIDE
3 5/8" 22 GAUGE
CORROSION-PROTECTED
STEEL RUNNER
SCHEDULED CEILING.
SEE ROOM FINISH SCHEDULE
8' - 0" AFF
EXISTING STRUCTURE
ACOUSTIC INSULATION
(1) LAYER 5/8" GWB
3 5/8" 22 GAUGE
CORROSION-PROTECTED
STEEL RUNNER
EXISTING CORRIDOR CEILING
EXISTING STRUCTURE
3 5/8" 22 GAUGE
CORROSION-PROTECTED
STEEL STUDS AT 16" O.C.
3 5/8" 22 GAUGE
CORROSION-PROTECTED
STEEL RUNNER
3 5/8" 22 GAUGE
CORROSION-PROTECTED
STEEL STUDS AT 16" O.C.
PROVIDE CROSS BRACING
TO EXISTING STRUCTURE
AS REQUIRED
3 5/8" 22 GAUGE
CORROSION-PROTECTED
STEEL RUNNER
LIGHT FIXTURE.
SEE ELECTRICAL DRAWINGS
EXISTING CEILING
3 5/8" 22 GAUGE
CORROSION-PROTECTED
STEEL RUNNER
3 5/8" 22 GAUGE
CORROSION-PROTECTED
STEEL STUDS AT 16" O.C.
(1) LAYER 5/8" GWB
**PROVIDE SMOKE/FIRE SEALANT AT PARITION/STUD/DECK CONNECTIONS
107 SF
COPY/MAIL ROOM
4230D
STC 45
d
/4
10' - 0"
AE300
AE500
AE500
84 SF
COMMUNICATIONS
CLOSET
4230N
135.00°
/8
V
IF
7' - 10" n
11" +/-
1" MIN
2' - 5 7/8"
9 1/4" 3 5/8"
ARCHITECTURAL GRILLE
B.O.D. AG10 A FRAME
4/4 (25 mm) X 3/4" (19 mm)
SOLID CHERRY EDGING
1/2" (13 mm) CHERRY
BACKER
2X3 FRAMING
M
IN
3/4" (19 mm) CHERRY
WOOD REMOVABLE
PANELING.
WOOD FRAMING
@24" O.C. AND ON EITHER
SIDE OF RADIATOR
FINISH NAIL TYP.
WOOD BASE (WS-1)
SCRIBE TO FLOOR
SCHEDULED FLOOR FINISH
EXIST. FLOOR STRUCTURE
EXIST. WINDOW FRAME
AND GLAZING TO REMAIN
WHERE PTAC COVERS MEETS
THE EXISTING STOREFRONT,
PROVIDE SPRAY-APPLIED
INSULATION FULL HEIGHT @ 2"
MAX. THICKNESS - COLUMN TO
COLUMN; TIGER FOAM E-84
CLOSED-CELL, CLASS 1 FIRE
RATED, OR APPROVED EQUAL
TO PREVENT
AIR TRANSFER.
SCHEDULED PTAC WORK.
SEE MECHANICAL.
1' - 2 1/2"
ARCHITECTURAL
GRILLE B.O.D. AG10 A
FRAME
/8
/4
/8
1/8" 1/4"
/4
/2
/8
2" MIN.8 1/2" +/- VIF
3/4"
1/2"
2 1/2"
3/4" (19 mm) CHERRY
WOOD
PANELING
WORK STATION
4230P
RECEPTION
W1
6" 7"
/2
/2
VB
SALVAGED TRANSACTION
WINDOW TO BE PROVIDED BY
GSA AND INSTALLED BY
CONTRACTOR.
1 1/2" THICK MAX
PLASTIC LAMINATE COUNTERTOP
NOTCHED AROUND DEAL TRAY
FURNISHED W/ SECURITY
WINDOW UNIT
PROVIDE SUFFICIENT BLOCKING
AS REQUIRED BY THE SECURITY
WINDOW MANUFACTURER FOR
PROPER INSTALLATION AND
SECUREMENT AROUND ENTIRE
OPENING PERIMETER
PROVIDE SUFFICIENT BLOCKING
AS REQUIRED BY THE SECURITY
WINDOW MANUFACTURER FOR
PROPER INSTALLATION AND
SECUREMENT AROUND ENTIRE
OPENING PERIMETER
PROVIDE ACOUSTIC SEALANT AT
ALL SIDES AS REQ.
PROVIDE ACOUSTIC SEALANT AT
ALL SIDES AS REQ.
JAMB BEYOND
S Y
S T
E M
F U
R N
IT
U
R E
W O
R K
S U
R F
A C
E
N
IC
M A
X
SYSTEM FURNITURE LOW
HEIGHT SUPPORT WALL.
NIC.
7/16" UL752 LEVEL 3
BULLET RESISTANT FIBERGLASS.
SEE WALL TYPE 03a
(THREAT SIDE)(SECURE SIDE)
03a
EXTERIOR
EXIST. STRUCTURAL
COLUMN
EXIST. AIR CAVITY
EXIST. EXTERIOR
MARBLE PANEL
EXIST. WINDOW FRAME
AND GLAZING TO
REMAIN
LAMINATE 5/8" GWB TO EXIST.
GWB - PREP., PRIME, PAINT AND
FINISH PER FINISH SCHEDULE
CUT AND REMOVE EXIST.
GWB AS NECESSARY TO
ACCESS SHAFT SPACE FOR
INSULATION INSTALLATION
EXIST. TO REMAIN METAL FRAMING
LINE OF FCU COVER BELOW
SPRAY-APPLIED INSULATION FULL
HEIGHT @ 2" MAX. THICKNESS - EACH
SIDE OF COLUMN; TIGER FOAM E-84
CLOSED-CELL, CLASS 1 FIRE RATED,
OR APPROVED EQUAL
FILL SPACE BETWEEN MARBLE
AND CONCRETE COLUMN USING
LOOSE FILL INSULATION, FULL
HEIGHT - EACH SIDE OF COLUMN
INTERIOR
LINE OF CHAIR RAIL BELOW
NKB
N. .______________________________________________________
ARCHITECTURE & ENGINEERING, PC..
K BHANDARI
RENOVATION
SHEET SIZE: 30 X 42
DRAWING NO.
CHECKED BY
DRAWN BY
FLOOR NO.
FILE NAME
DRAWING TITLE
SUB. DATE
SUBMISSION
GSA PM
PROJECT NO.
PROJECT
DESCRIPTION
PROJECT
TITLE
FACILITY CODE
OTHER
BUILDING NOs.
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
CONSTR. FIRM
SUB A/E
PRIME A/E
A/E CON. NO.
D R
A W
IN
G
P R
O J E
C T
B U
IL
D
IN
G
C O
N T
R A
C T
O R
S G
R A
P H
IC
S C
A L
E R
E V
IS
IO
N N
O T
E S
C E
R T
IF
IC
A T
IO
N
S
MARK DATE DESCRIPTION
SHEET OF
NK BHANDARI ARCHITECTURE
C&S
GS-07-P-16-UC-D-7008
K E
Y P
L A
N
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
DATE:
1 2 3 4 5 6
E
D
C
B
A
1 2 3 4 5 6
SUB A/E
CONSTR. CON. -
NYS EDUCATION LAW, SECTION 7209 AND 69.5(B)
PROHIBITS ANY PERSON TO ALTER THESE DRAWINGS
OTHER THAN A LICENSED ARCHITECT OR THE DESIGN
ENGINEER. INFORMATION ON THESE DRAWINGS FOR
GSA ONLY, AND CAN BE UTILIZED BY GSA AS THEY
DEEM NECESSARY.
COPYRIGHT 2019
N. K. BHANDARI, ARCHITECTURE & ENGINEERING, P.C.
1005 W. Fayette Street, Suite 500 Syracuse, NY 13204
Phone Fax www.nkbpc.com
315.428.1177 315.428.9822
499 Col. Eileen Collins Blvd Syracuse, NY 13212
Phone www.cscos.com
315.455.2000
SPECIAL
PROGRAMS
DIVISION
100 STATE STREET
ROCHESTER, NY 14614
C:\Users\pdd\Documents\R19_GSA_KEATING TRUSTEES_CENTAL_ADDENDUMS_pdudkowskiD8JHD.rvt
/6
/2
:0
:0
A
M
DETAILS
KEATING FED. BLDG U.S.T.
4TH FLR RENOVATION
DBH
JLHS 08/30/2019
N1777507
08/30/2019
10 29
CONSTRUCTION DOCUMENTS
AE501
ERIN BISHOP
KENNETH B. KEATING FED.
3/4" = 1'-0"AE501
1 TYPICAL BLOCKING DETAIL
3/4" = 1'-0"AE501
2 TYPICAL BLOCKING DETAIL
12" = 1'-0"AE501
3 CHAIR RAIL
1" = 1'-0"AE201 AE501
4 SOFFIT DETAIL
1" = 1'-0"AE201 AE501
5 CEILING EDGE DETAIL
1 12/06/19 ADDENDUM #2
2 01/03/20 ADDENDUM #3
1/2" = 1'-0"AE101 AE501
6 ENLARGED PLAN - COPY/MAIL ROOM
1/2" = 1'-0"AE101 AE501
7 ENLARGED PLAN - ADP ROOM
3" = 1'-0"AD-1 AE501
8 PTAC COVER DETAIL
1 1/2" = 1'-0"AD-1 AE501
9 RECEPTION 4230 - TRANSACTION WINDOW
3" = 1'-0"AE101 AE501
10 COLUMN ENCLOSURE