AE101-ADDENDUM_3.pdf

PDF 772 KB Posted

Attached to
US Trustee 4th Floor Keating Renovation Federal contract opportunity
Solicitation number
47PC1120R0003
Issued by
General Services Administration Public Buildings Service Region 2

About this file

This solicitation seeks contractors to furnish all materials, equipment, labor, and supervision for the "Keating 4th Floor US Trustees Relocation Project" located at the Kenneth B. Keating Federal Building and U.S. Courthouse in Rochester, New York. The approximately 2,700 square foot renovation includes reception, workstations, enclosed offices, storage, mail room, break room, conference room, and associated circulation space to support the work functions of the US Trustees. Base interior work includes hazardous material abatement, new walls, doors, casework, woodwork, flooring, plumbing, electrical, fire protection and mechanical systems. Additionally, technology, data and security infrastructure work is required. The project was designed by N.K. Bhandari Architecture & Engineering P.C. of Syracuse, New York. Award will be made as a firm fixed price construction contract to a responsible bidder in accordance with FAR 15.3. The estimated contract value is between $500,000 and $1,000,000. The NAICS code is 236220 with a size standard of $38.5 million. Performance and payment bonds are required following award pursuant to the Miller Act. A bid guarantee is also required. The procurement is 100% set-aside for small business concerns, with offers from other than small businesses not being considered. The required construction completion date is approximately 192 calendar days after notice to proceed.

View the file

Other files for this federal contract opportunity

Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R E

F

2466 2466

246636663666

3'-0"

144 SF

WORK ROOM

4230E

184 SF

BREAK ROOM

4230F

STC 45

141 SF

OFFICE

4230H

220 SF

AUST. OFFICE

4230J

STC 45 148 SF

OFFICE

4230K

362 SF

CONFERENCE

ROOM

4230M

STC 45

86 SF

STORAGE

4230B

86 SF

RECEPTION

STC 45

84 SF

COMMUNICATIONS

CLOSET

4230N

65 SF

WORK STATION

4230L

86 SF

WORK STATION

4230P b c d

4230g

4230h

4230j k m n

4230a 4230

17 SF

CLOSET

4230G

609 SF

CIRCULATION

4230A

AE300 11

03a

A L

IG

N

ALIGN

A L

IG

N

ALIGN

ALIGN

ALIGN

C L E

A R

A L

IG

N

2' - 6"

AE300

778 SF

MEETING ROOM

a

240 SF

ROOM 4220

E Q

E Q

AE300

AE300

AE300

AE500

AE500

ALIGN

AE500

AE501

99 99

ALIGN

/8

V

IF

AE501

AE501

AE501

AE501

AE501

AE501

AE500

NIC

NIC

NIC

NIC

NIC

107 SF

COPY/MAIL ROOM

4230D

STC 45

196 SF

CASE FILE ROOM

4230C

03a

AE501

AE501

AE300

p

4230f

4230e

EX

EX

A

A

A

A

A

A

A

A

A

A

B

A

A

AE500

AE500

ALIGN

5' - 5" 5' - 5"

/8 " 1

/8

10' - 4 7/8" 9' - 4 7/8"

1' - 2 7/8"

/8

03b

W1 03b

03b

AE501

11 1111

AE501

Sim

AE501

Sim

AE501

Sim

AE501

Sim

AE501

Sim

AE501

Sim

NKB

N. .______________________________________________________

ARCHITECTURE & ENGINEERING, PC..

K BHANDARI

RENOVATION

SHEET SIZE: 30 X 42

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs.

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. FIRM

SUB A/E

PRIME A/E

A/E CON. NO.

D R

A W

IN

G

P R

O J E

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R A

P H

IC

S C

A L

E R

E V

IS

IO

N N

O T

E S

C E

R T

IF

IC

A T

IO

N

S

MARK DATE DESCRIPTION

SHEET OF

NK BHANDARI ARCHITECTURE

C&S

GS-07-P-16-UC-D-7008

K E

Y P

L A

N

SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

DATE:

1 2 3 4 5 6

E

D

C

B

A

1 2 3 4 5 6

SUB A/E

CONSTR. CON. -

NYS EDUCATION LAW, SECTION 7209 AND 69.5(B)

PROHIBITS ANY PERSON TO ALTER THESE DRAWINGS

OTHER THAN A LICENSED ARCHITECT OR THE DESIGN

ENGINEER. INFORMATION ON THESE DRAWINGS FOR

GSA ONLY, AND CAN BE UTILIZED BY GSA AS THEY

DEEM NECESSARY.

COPYRIGHT 2019

N. K. BHANDARI, ARCHITECTURE & ENGINEERING, P.C.

1005 W. Fayette Street, Suite 500 Syracuse, NY 13204

Phone Fax www.nkbpc.com

315.428.1177 315.428.9822

499 Col. Eileen Collins Blvd Syracuse, NY 13212

Phone www.cscos.com

315.455.2000

SPECIAL

PROGRAMS

DIVISION

100 STATE STREET

ROCHESTER, NY 14614

C:\Users\pdd\Documents\R19_GSA_KEATING TRUSTEES_CENTAL_ADDENDUMS_pdudkowskiD8JHD.rvt

/6

/2

:0

:0

A

M

NEW CONSTRUCTION PLAN

KEATING FED. BLDG U.S.T.

4TH FLR RENOVATION

DBH

JLHS 08/30/2019

N1777507

08/30/2019

6 29

CONSTRUCTION DOCUMENTS

AE101

ERIN BISHOP

KENNETH B. KEATING FED.

1/4" = 1'-0"AE101

1 FOURTH FLOOR NEW CONSTRUCTION PLAN

0 2' 4' 8'

FLOOR PLAN - KEYED NOTES- AE101

NO. DESCRIPTION

1 PROVIDE WALL INFILL WITH 3 5/8" METAL STUD, SHEATH AND FINISH TO MATCH

EXISTING ADJACENT MATERIALS. COORDINATE WITH BUILDING MANAGER TO

OBTAIN ATTIC STOCK TO FINISH WALL ON CORRIDOR SIDE.

2 PROVIDE WALL INFILL WITH 3 5/8" METAL STUD, SHEATH AND FINISH TO MATCH

EXISTING ADJACENT MATERIALS.

3 PROVIDE SCHEDULED DOOR LEAF AND HARDWARE IN EXISTING DOOR FRAME. SEE

DOOR AND HARWARE SCHEDULES.

4 PROVIDE LVT FLOORING INFILL AND RUBBER TRANSITION STRIP.

5 PROVIDE UPPER CABINETRY, SOLID SURFACE COUNTER TOP, LOWER CABINETRY

AND SINK.

6 PROVIDE SOLID SURFACE COUNTER TOP, SOLID SURFACE WALL CAP AND LOWER

CABINETRY.

7 WORK STATIONS, TABLES AND CHAIRS SHOWN FOR REFERENCE ONLY. NOT IN

CONTRACT.

8 PAINT EXISTING DOOR 4230p DOOR FRAME. SEE DOOR SCHEDULE.

9 PROVIDE REFRIGERATOR AND MICROWAVE. SEE SPECIFICATIONS.

10 PER FINISH SCHEDULE. THIS WALL LOCATION WILL BE PAINTED IN THE BLUE

ACCENT PAINT

11 PROVIDE INSULATION TO PREVENT EXTERIOR AIR INFILTRATION WHERE PTAC

MEETS EXISTING STOREFRONT, WHERE THE EXISTING EXTERIOR MARBLE PANELS

MEET THE CONCRETE COLUMNS, AND ABOVE THE METAL VALANCE AT THE HEAD

OF THE EXIST. STOREFRONT - REFER TO DETAILS 8 AND 10 ON SHEET AE501.

1 12/06/19 ADDENDUM #2

2 01/03/20 ADDENDUM #3

GENERAL NOTES

1 ALTHOUGH NOTED AS "NIC", SOME AREAS OF THE BUILDING NOT IN THE

WORK AREAS WILL NEED TO BE ACCESSED FOR PREPARATION AND

INSTALLATIION OF SCHEDULED WORK.

2 EXISTING WINDOW TREATMENTS TO REMAIN THROUGHOUT CONSTRUCTION

AND BE CLEANED AT END OF CONSTRUCTION SERVICES BY CONTRACTOR.

Sheets
AE101 - NEW CONSTRUCTION PLAN
AE501 - DETAILS

File details come from the government source that posted it. Updated .