About this file
This document provides details for a federal construction contract opportunity with the General Services Administration to renovate approximately 2,700 square feet of space for the US Trustees office in the Kenneth B. Keating Federal Building in Rochester, New York. The renovation will include elements to support the work functions of the US Trustees such as reception, workstations, enclosed offices, storage, mail room, break room and conference room. Base interior work will include hazardous material abatement, new walls, doors, casework, flooring, plumbing, electrical, fire protection and mechanical systems. Additionally, technology, data and security infrastructure work is required. The construction completion date is approximately 192 calendar days after notice to proceed. The procurement is set aside for small businesses with offers from other than small businesses not being considered. Interested contractors must register in the System for Award Management and complete Representations and Certifications to receive specifications and drawings. The point of contact is James Berring, Contracting Officer, for any questions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment 47PC1120R0003_0002.pdf | ||
| Keating 4th Floor UST Addendum #3 2020-01-03.pdf | ||
| AE101-ADDENDUM_3.pdf | ||
| AE501-ADDENDUM_3.pdf | ||
| RFI QA part 2, 47PC1120R0003.pdf | ||
| RFI QA, 47PC1120R0003.pdf | ||
| 20190307_Narrative_Keating_4th Floor UST Office Reno2.pdf | ||
| GE Microwave.pdf | ||
| GE Refrigerator.pdf | ||
| Solicitation Amendment 47PC1120R0003_0001.pdf | ||
| GSA527.pdf | ||
| Reps&Certs for 47PC1120R0003.docx | DOCX document | |
| Agreement, 47PC1120R0003, Keating 4th Fl Relocation.pdf | ||
| Attachment 2, PBS Past Performance Questionnaire.pdf | ||
| SF1442, 47PC1120R0003 Form.pdf | ||
| Wage Determination, NY 20190010, 10 25 2019.pdf | ||
| Attachment 3 - Experience on Similar Projects Offeror Form.xlsx | XLSX spreadsheet | |
| DocumentSecurityStatement, 47PC1120R0003.pdf | ||
| Attachment 1, Proposal Breakdown Template.xlsx | XLSX spreadsheet | |
| Solicitation, 47PC1120R0003, Keating 4th Fl Relocation.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM NO. 2
Project: U.S. Trustees Office – 4th Floor Renovation
Kenneth B. Keating Federal Office Building and US Courthouse
Buffalo, NY 14202
GSA Project: N17777507 [NKB#12245.53]
A/E Contract No.: GS-07-P-16-UC-D-7008
Date of Issue: December 06, 2019
Attachments: Job Drawings
TO ALL BIDDERS: The following additions, deletions, and/or changes or clarifications to the drawings, specifications, and bidding documents for this project, shall become and are hereby made part of the Contract Documents. They change the original documents only in the manner and to the extent stated.
Each bidder shall acknowledge receipt of this ADDENDUM in the appropriate location on the bid proposal form.
This ADDENDUM consists of two (2) pages, including this page. All requirements of the original Specifications and Drawings and previous
Addendum, if applicable, shall remain in force except as noted by this
ADDENDUM.
THE PURPOSE OF THIS ADDENDUM IS TO CHANGE THE FOLLOWING ITEMS:
DRAWINGS
1.1 ADD Job Drawing AD-1
The intent is to incorporate the changes to the work shown on Job Drawing AD-1 for additional ballistic door / window / wall protection (three walls of Reception 4230, the entry door 4230a, and the security/transaction window shall meet the UL752 Level 1
Bullet-Resisting rating)
The intent is also to incorporate the reuse and reinstallation of the existing US Trustees transaction window salvaged on-site by GSA property management.
END OF ADDENDUM NO. 2
B
M B B C
E K F B G
F L P R
AE300
AE501
86 SF
STORAGE
4230B
86 SF
RECEPTION
STC 45
n
4230a 4230
03a
ALIGN
ALIGN
03a
A
03b
W1 03b
03b
WT-03b:
UL --
RATING 0 HOUR
STC --
EXISTING METAL STUD / BULLET RESISTANT
FIBERGLASS / GYPSUM WALL BOARD
EXISTING WALL STUDS
(1) LAYER 5/8" GWB
BOTTOM OF FLOOR STRUCTURE
TOP OF FLOOR STRUCTURE
7/16" UL752 LEVEL 3 BULLET
RESISTANT FIBERGLASS
(THREAT SIDE)
03b
NKB
N. .______________________________________________________
ARCHITECTURE & ENGINEERING, PC..
K BHANDARI
1005 W. Fayette Street, Suite 500
Syracuse, NY 13204
Phone 315.428.1177
Fax 315.428.9822 www.nkbpc.com
SHEET OF
DRAWN:
CHECKED:
SCALE: AS NOTED
DATE:
DRAWING NO.
PROJECT
NUMBER:
DRAWING TITLE
NYS EDUCATION LAW, SECTION 7209 AND 69.5(B)
PROHIBITS ANY PERSON TO ALTER THESE DRAWINGS
OTHER THAN A LICENSED ARCHITECT OR THE DESIGN
ENGINEER. INFORMATION ON THESE DRAWINGS FOR
GSA ONLY, AND CAN BE UTILIZED BY GSA AS THEY
DEEM NECESSARY.
COPYRIGHT 2019
N.K. BHANDARI, ARCHITECTURE & ENGINEERING, P.C.
GSA PROJECT
MANAGER:
GSA CONTRACT
NUMBER:
REVISIONS
MARK DATE DESCRIPTION
GS-07-P-16-UC-D-7008
ERIN BISHOP
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.1
/6 /2
:1 :3
P
M
K E
A T
IN
G
F E
D
B L
D G
U .S
.T
T
H F
L R
R E
N O
V A
T
IO
N
AD-1
DBH
JLHS
12/06/19
E n te r a d d re s s h e re
E R
IN
B
IS
H
O P
RECEPTION REVISIONS
N1777507
DOOR SCHEDULE 4230a
DOOR
ROOM
NAME
ROOM
DOOR FRAME
THRESHOLD
FIRE
RATING REMARKS
HARDWARE
SETWIDTH HT THICKNESS
LEAF
SIZE TYPE
DOOR
MATERIAL FINISH
FRAME
TYPE
FRAME
MATERIAL
FRAME
FINISH
FRAME
DETAIL
4230a CIRCULATION 4230A 3' - 0" 7' - 0" 0' - 1 3/4" 36 F WD STN H1 HM PNT 1 & 2/AE600 NA - 1, 2 3
WINDOW SCHEDULE
NUMBER DESCRIPTION COUNT DETAIL
W1 SALVAGED TRANSACTION WINDOW TO BE
PROVIDED BY GSA AND INSTALLED BY
CONTRACTOR.
1 9/AE501
DOOR SCHEDULE REMARKS
1 ELECTRONIC SECURITY - REFER TO HARDWARE SETS AND SECURITY
DRAWINGS
2 BALLISTIC WOOD DOOR BASIS OF DESIGN: CURRIES / ASSA ABLOY 737
SERIESUL 752 LEVEL 1 DOOR AND FARME WITH WOOD VENEER TO MATCH
REMAINDER OF DOOR PACKAGE. INCLUDE CLOSER AND LOCKSET
REINFORCEMENT FOR COORDINATION WITH HARDWARE SET.
1/4" = 1'-0"AD-1
1 PARTIAL FOURTH FLOOR NEW CONSTRUCTION PLAN
WALL TYPE WT-03b
1 12/06/19 ADDENDUM #2
| Sheets |
| AD-1 - RECEPTION REVISIONS |
File details come from the government source that posted it. Updated .