36C26118B0618-009.pdf
PDF 5 MB Posted
- Solicitation number
- 36C26118B0618
About this file
This notice provides information about an upcoming Invitation for Bid for Project 612-501 to construct a new Dermatology Outpatient Service Building.
The solicitation will be issued on or about July 20, 2019 for a single, firm-fixed price contract to provide all labor, materials, permits and supervision to construct the new building. The period of performance is 500 days from notice to proceed. The construction magnitude is between $5-10 million. The project location is VA Northern California Healthcare System in Mather, CA.
This procurement will be set aside as a total small business set-aside for Service-Disabled Veteran-Owned Small Businesses. The NAICS code is 236220 for Commercial and Institutional Building Construction with a $36.5 million size standard. The solicitation and drawings will be available on FBO and amendments must be monitored there, as hard copies will not be distributed. Interested parties have until issuance to check the website for notices and changes to requirements. The contract will be awarded following sealed bid procedures in the FAR.
36C26118B0618 C27 - 02-12-18 - ELECTRICAL - MATHER - DERMATOLOGY - 10TH SUBMITTAL.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26118B0618-0004001.docx | DOCX document | |
| 36C26118B0618-0004000.docx | DOCX document | |
| 36C26118B0618-0003000.docx | DOCX document | |
| 36C26118B0618-0003001.pdf | ||
| 36C26118B0618-0003002.pdf | ||
| 36C26118B0618-0002000.docx | DOCX document | |
| 36C26118B0618-0001000.docx | DOCX document | |
| 36C26118B0618-0001001.pdf | ||
| 36C26118B0618-008.pdf | ||
| 36C26118B0618-012.pdf | ||
| 36C26118B0618-017.pdf | ||
| 36C26118B0618-007.pdf | ||
| 36C26118B0618-015.pdf | ||
| 36C26118B0618-003.pdf | ||
| 36C26118B0618-013.pdf | ||
| 36C26118B0618-010.pdf | ||
| 36C26118B0618-011.pdf | ||
| 36C26118B0618-014.pdf | ||
| 36C26118B0618-004.pdf | ||
| 36C26118B0618-005.pdf | ||
| 36C26118B0618-006.pdf | ||
| 36C26118B0618-016.pdf | ||
| 36C26118B0618-002.docx | DOCX document | |
| 36C26118B0618-001.docx | DOCX document |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECEPTACLE SHALL BE MOUNTED 18" ON CENTER AFF, AND SWITCHES AND WALL
OCCUPANCY SWITCHES SHALL BE MOUNTED 48" ON CENTER AFF, UNLESS
OTHERWISE NOTED
RECEPTACLE, TELECOMMUNICATION OUTLET AND SWITCH SUFFIX OF:
-A MOUNTED ±6" ABOVE COUNTERTOP OR BACKSPLASH.
-B MOUNTED ±6" FROM THE EDGE OF THE SINK TOP AND ±40" AFF OR
±6" ABOVE THE EDGE OF THE SINK TOP
-C MOUNTED ON CEILING
-F MOUNTED ON FLOOR
-W MOUNTED 48" AFF
-H MOUNTED ±12" BELOW CEILING LINE
-S SURFACE MOUNTED
GFCI GROUND FAULT CIRCUIT INTERRUPTER
SC SAFETY TYPE (TAMPER RESISTANT)
WP WEATHER PROTECTED (NEMA 3R) ENCLOSURE
PHASE CONDUCTOR
NEUTRALGROUND
IDENTIFIES PANEL AND CIRCUIT NUMBER(S). HASH MARKS INDICATES NUMBER
COMBINATION MOTOR STARTER, CIRCUIT BREAKER TYPE
A, B, C INDICATES SEPARATE CONTROL OF CIRCUITS AS DESIGNATED
5-20R, GROUNDING TYPE - EMERGENCY POWER
DUPLEX RECEPTACLE, NEMA 5-20R, GROUNDING
TYPE WITH GROUND FAULT CIRCUIT INTERRUPTER (GFCI) - EMERGENCY POWER
DUPLEX RECEPTACLE, NEMA 5-20R, GROUNDING
QUADRAFLEX-RECEPTACLE (DOUBLE DUPLEX), NEMA 5-20R,
GROUNDING TYPE WITH GROUND FAULT CIRCUIT INTERRUPTER - EMERGENCY POWER
QUADRAFLEX-RECEPTACLE (DOUBLE DUPLEX), NEMA
QUADRAFLEX-RECEPTACLE (DOUBLE DUPLEX), NEMA
ELECTRIC PANELBOARD, FLUSH MOUNTED
ELECTRIC PANELBOARD, SURFACE MOUNTED
MOTOR, 3 PHASE
SWITCH, 20A, 1 POLE, 120/277 V, UNLESS OTHERWISE INDICATED
OF PHASE, NEUTRAL AND GREEN GROUND WIRES
BRANCH CIRCUIT HOMERUN TO PANELBOARD; LETTER AND NUMBER NOTATION
CONDUIT OR WIRE RUN EXPOSED OR ABOVE THE CEILING
5-20R, GROUNDING TYPE WITH GROUND FAULT CIRCUIT INTERRUPTER
QUAD-RECEPTACLE (DOUBLE DUPLEX), NEMA
DUPLEX RECEPTACLE, NEMA 5-20R, GROUNDING
TYPE WITH GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
DUPLEX RECEPTACLE, NEMA 5-20R, GROUNDING TYPE
DISCONNECT SWITCH, FUSED
D DIMMER
4 4 WAY SWITCH
3 3 WAY SWITCH
DISCONNECT SWITCH, UNFUSED
SP SPEAKER-PUBLIC ADDRESS/PAGING
GENERAL NOTES
SUFFIX OF:
THERMOSTAT
ELECTRICAL DISTRIBUTION PANEL
S
T
EP
TYPE - EMERGENCY POWER
GFCI
A-1,3
GFCI
5-20R, GROUNDING TYPE
JUNCTION BOX
GFCI
GFCI
J J
CURRENT TRANSFORMER
POWERPWR
GROUND FAULT CIRCUIT-INTERRUPTER
MISCELLANEOUS
MINIMUM
NOT APPLICABLE
MOUNTING
MOUNTED
N/A
MTD
MTG
MISC
MIN
GFP GROUND FAULT PROTECTION
GOVERNMENT
MECHANICAL
LOCATION
KILOVOLT
MAXIMUM
GREEN
HAND-OFF-AUTOMATIC
HERTZ
KILOWATT
KILO-AMPERES
HEIGHT
LIGHT
KILOVOLT-AMPERE
JUNCTION BOX
GROUND
LOC
MECH'L
MAX
LTG
KV
KW
KA
KVA
H-O-A
J.B.
Hz
HT
GRN
GOV
GNDGND
FLOOR
COPPER
ELEVATION
ELECTRIC
DRAWING
DISCONNECT
DISTRIBUTION
EQUIPMENT
FOOT, FEET
EXISTING
FLOOD
GALVANIZED
FULL LOAD AMPS
ELECTRICAL METALLIC TUBING
EQUIP
EXIST/(E)
FLD
GALV
GFCI
FLR
FT
FLA
ELECT
DWG
EMT
ELEV
DIST
DISC
CT
CU
SHIELDED TWISTED WIRE PAIR
MOUNTING HEIGHT ABOVE FINISHED+12"A.F.F.
Ø
WT
XFMR
WP
W
V
VA
UON
FLOOR OR GRADE
PHASE
UNLESS OTHERWISE NOTED
WEATHERPROOF
WIRE TROUGH
TRANSFORMER
WIRE
VOLT AMPS
VOLT
STP
U/G
UL
UBC
TYP
TBD
TEMP
TERM
TV
SMUD
SWBD
SW
ST
RECEPT
RGS
RPS
UNDERWRITERS LABORATORIES
UNIFORM BUILDING CODE
UNDERGROUND
TYPICAL
TO BE DETERMINED
TERMINAL
TEMPORARY
TELEVISION
RIGID GALVANIZED STEEL
SWITCHBOARD
SWITCH
SACRAMENTO MUNICIPAL UTILITY DISTRICT
STREET
RECEPTACLE
REMOTE POWER SUPPLY
CONTRACTING OFFICER REPRESENTATIVE
ELECTRICAL ABBREVIATIONS
AMERICAN NATIONAL STANDARDS INSTITUTE
COMMUNICATION
CATALOG
CEILING
CONDUIT
CIRCUIT
CONNECTED
CIRCUIT BREAKER
AMPERE
AMPS INTERRUPTING CAPACITY
BUILDING
BARE COPPER
AMERICAN WIRE GAUGE
ABOVE FINISHED FLOOR
COMM
CONN
CLG
COR
CKT
C
CAT
C.B.
BLDG
A/AMP
AWG
B.C.
AIC
ANSI
AFF
2.
1.
MANUFACTURERS ASSOCIATION
PNL
PRI
PVC
PH
PR
PA
P
O.L.
NEMA
NF
NTS
NO.
NEC
PUBLIC ADDRESS
POLYVINYL CHLORIDE
PANEL
PRIMARY
PHASE
PAIR
OVERLOAD
POLE
NATIONAL ELECTRICAL
NOT TO SCALE
NATIONAL ELECTRICAL CODE
NON-FUSED
NUMBER
1. PENETRATION OF CONDUITS, RACEWAYS AND WIRING THROUGH FIRE RATED WALLS, FLOOR AND
CEILINGS SHALL BE FIRE-STOPPED IN ACCORDANCE WITH SPECIFICATION SECTION 07 84 00. FIRE
STOPPING MATERIALS AND METHODS SHALL BE A U.L. LISTED ASSEMBLY.
2. METHODS AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL
ELECTRICAL CODE (NEC). EQUIPMENT SHALL BE IN ACCORDANCE WITH THE STANDARDS OF NEMA
AND ANSI. EQUIPMENT SHALL BE NEW AND LISTED BY U.L. AND INSTALLED IN ACCORDANCE WITH
THE CONDITIONS STATED IN THAT LISTING.
3. BEFORE ENERGIZING, EQUIPMENT SHALL BE TESTED TO BE FREE OF GROUNDS AND SHORTS.
4. RECEPTACLES, OUTLETS, SWITCHES, DISCONNECT, CONDUITS AND JUNCTION BOXES (ABOVE AND
BELOW CEILING) SHALL BE PERMANENTLY MARKED AS TO INDICATE THE CIRCUIT NUMBER AND
SOURCE PANELBOARD. PERMANENT MARKING FOR BELOW THE CEILING DEVICES SHALL BE CLEAR 3/8" WIDE STICK-ON LABEL WITH BLACK LETTERING. PERMANENT MARKING FOR ABOVE THE CEILING
DEVICES MAY BE HAND LABELED WITH PERMANENT MARKER.
5. UNLESS OTHERWISE INDICATED, POWER AND LIGHTING CONDUCTORS SHALL BE TYPE THHN/THWN, 600 VOLT, SOLID OR STRANDED COPPER IN ACCORDANCE WITH SPECIFICATIONS, AND NOT
SMALLER THAN #12 AWG FOR POWER AND LIGHTING CIRCUITS AND #14 AWG FOR CONTROL
CIRCUITS.
6. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED IN STRICT ACCORDANCE WITH THE LATEST
EDITION OF NATIONAL ELECTRIC CODE (NEC). PROVIDE EQUIPMENT GROUNDING CONDUCTORS.
CONDUIT CANNOT BE USED AS THE ONLY MEANS OF GROUNDING.
7. FIXTURES AND EQUIPMENT SHALL BE SUPPORTED/MOUNTED TO COMPLY WITH THE SEISMIC
REQUIREMENTS OF THE IBC AND ASCE 7.
8. CONDUIT CONNECTIONS TO MOTORS AND LIGHTING FIXTURES SHALL BE MADE WITH FLEXIBLE
METAL OR LIQUID TIGHT FLEXIBLE CONDUIT NOT MORE THAN 6 FEET LONG.
9. MECHANICAL ELECTRICALLY OPERATED EQUIPMENT SHALL BE PROVIDED WITH "WITHIN SIGHT"
PADLOCKABLE DISCONNECTING SWITCH CONSISTING OF HORSEPOWER RATED SWITCH, MOLDED
CASE CIRCUIT BREAKER OR TOGGLE SWITCH, IN ACCORDANCE WITH NEC. OUT OF SIGHT
LOCKABLE DISCONNECTING DEVICES ARE NOT ACCEPTABLE TO MEET THIS REQUIREMENT.
10. CONTRACTOR SHALL COORDINATE ELECTRICAL WORK WITH OTHER TRADES.
11. LABEL AND IDENTIFY ALL PANEL SCHEDULES.
12. PROVIDE DEDICATED NEUTRAL ON EACH NEW 120V AND 277V CIRCUITS.
13. ALL CONDUITS SHALL BE CONCEALED IN ACCORDANCE WITH SPECIFICATION 26 05 33. CONDUITS
SHALL RUN ABOVE THE CEILING OR BEHIND THE FINISH WALL, UNLESS OTHERWISE NOTED.
14. "PROVIDE" MEANS "FURNISH AND INSTALL".
15. ALL ELECTRICAL CONSTRUCTION WORK, METHODS AND MATERIALS SHALL BE IN COMPLIANCE WITH
THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) AND APPLICABLE GOVERNMENT
AND VETERANS ADMINISTRATION RULES AND REGULATIONS.
16. ROUTE ALL TELECOMMUNICATION CIRCUITS 18" MINIMUM APART FROM ELECTRICAL CIRCUITS. IN
LOCATIONS WHERE MINIMUM SEPARATION CAN NOT BE OBTAINED, WRAP TELECOMMUNICATION
CIRCUITS WITH GROUNDED METALLIC SHEET TO REDUCE NOISE INTERFERENCE.
17. ALL TELECOMMUNICATION WIRES SHALL BE SUPPORTED BY HANGERS OR WIRE TRAYS. WIRES LAID
ON SUSPENDED CEILING IS PROHIBITED.
18. ALL ABOVE CEILING RACEWAYS, OUTLETS, J.B's AND PULL BOXES SHALL BE HUNG ON THE
CONCRETE SLAB. WALL MOUNTING IS NOT PERMITTED.
19. PROVIDE ADDITIONAL ACCESS PANEL, AS REQUIRED, ON HARD CEILING FOR ELECTRICAL DEVICES, EQUIPMENT, JUNCTION BOXES, ETC. ACCESS.
ELEC'L ELECTRICAL
CO CONTRACTING OFFICER
HATCHED GRAY THIN LINE INDICATES DEMOLISH PER DRAWING NOTES
DETAIL NUMBER
DRAWING NUMBER ON WHICH DETAIL IS DRAWN
NOTE REFERENCE
PS POWER SUPPLY
TV COAXIAL CABLE OUTLET
BOLD LINE INDICATES NEW WORK
CONDUIT OR WIRE RUN UNDERGROUND
INTERNATIONAL BUILDING CODEIBC
TELECOM TELECOMMUNICATION
VFD VARIABLE FREQUENCY DRIVE
OS OCCUPANCY SENSOR - CEILING MOUNTED
OCCUPANCY WALL SWITCH - WALL MOUNTEDOS
TELECOMMUNICATION OUTLET, QUAD (4 DATA)
TELECOMMUNICATION OUTLET, DUPLEX (2 DATA)
PUSHBUTTON
VAMC VETERANS AFFAIRS MEDICAL CENTER
H HEATER
RECEPTACLE, NEMA 6-20R, OR 6-30R 250V (GROUNDING TYPE)
RECEPTACLE, NEMA 6-20R, 250V (GROUNDING TYPE) - EMERGENCY POWER
RECEPTACLE, NEMA L6-20R, 250V TWIST LOCK
(GROUNDING TYPE) - EMERGENCY POWER
CEILING RECESSED LIGHTING FIXTURE (TYP.) LETTER IN LIGHT FIXTURE DESIGNATES
FIXTURE TYPE. SEE LIGHTING FIXTURE SCHEDULE FOR DETAILS.
GRAY THIN LINE INDICATES EXISTING WORK
SP
WI-FI FIXTURE
M T
MOTION DETECTOR
SUFFIX 'P' INDICATES ADDITIONAL AMBIENT LIGHT CONTROL FEATURE
SPECIAL RECEPTACLE, PER EQUIPMENT MANUFACTURER'S REQUIREMENT
SUFFIX OF:
P INDICATES ADDITIONAL AMBIENT LIGHT CONTROL FEATURE
F 360° COVERFACE
H 180° COVERFACE
T TRANSFORMER
XX###
RM ROOM
LEGEND LEGEND
ELECTRICAL STRIP MOLD OUTLETS
MOTOR, 1 PHASE
TV
SURFACE MOUNTED CEILING STRIP LIGHT
SUSPENDED STRIP LIGHT
EXIT SIGN
IN-FLOOR POKE-THRU TELECOMMUNICATION OUTLET, QUAD (4 DATA)
X
X
X
X
X CEILING RECESSED LIGHTING FIXTURE ON EMERGENCY POWER (TYP.)
P PHOTOCELL; NEMA 3R ENCLOSURE
CABLE TRAY
UTP UNSHIELDED TWISTED PAIR
RECESSED DOWNLIGHT
L
X
SCHED SCHEDULE
MAIN LUG ONLYMLO
X - DESIGNATE 6-20R Y - DESIGNATE 6-30R
20. CONTRACTOR IS RESPONSIBLE FOR ALL COST, PERMITS, COORDINATION AND OBTAIN APPROVAL
FROM SMUD ON ALL SMUD RELATED EQUIPMENT, TRANSFORMER PAD, GROUNDING, SMUD
METER AND MAIN CIRCUIT BREAKER STRUCTURE, ENCLOSURES, CONDUITS, WIRING SELECTION
AND INSTALLATION. CONTRACTOR SHALL SUBMIT APPLICATION TO SMUD FOR NEW SERVICES
INCLUDING FEES.
20A, 2P, 3 WIRE, 250V GROUNDING, FLUSH MOUNTED,
TWIST LOCK RECEPTACLE
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
3/13/2018 9:03:32 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
E101
ELECTRICAL GENERAL NOTES,
LEGEND AND ABBREVIATIONS
A. LEUNG
612-501
E. MITCH
117 151
F.E.C.
F .E
.C
DD
D
DD
D
D
D
3D 3D
OS
ab b
C1
D1
D1 D1
B1
D1D1
D1
D1
C1
E2
E2 E2
E2
U U U
U
U
U
U
U
U a b
M A
T C
H L
IN
E S
E E
E L -2
Q
225 SF
ELECTRICAL
1A15
710 SF
MECHANICAL
1A14
108 SF
MULTI
PURPOSE
1A02B
100 SF
I.T.
1A16
102 SF
OFFICE
1A02A
847 SF
CORRIDOR
1AC2
170 SF
LASER
1A12
123 SF
EXAM
ROOM
1A11
124 SF
EXAM
ROOM
1A10
1(TYP.)
A
B
C
D
C4
D1
A.3
A.7
B.3
(TYP.)
c a b b
C1 b
3 8 (TYP.)
U c a
U
U
U a c c a a a a a a a c
PHOTOCELL CIRCUIT
"c" ON ROOF
PHOTOCELL CIRCUIT
"a" ON ROOF
2 2 a a a
(TYP.)4
(TYP.)
3 8 (TYP.)
3 8 (TYP.)
M A
T C
H L
IN
E S
E E
E L -2
T1
T1
T1
T1
T1
6441Z-EHP01, CKT 23
O S
OS
N 26
C1
26 26
PNL 6441Z-NHD01,
CKT 26
PNL 6441Z-NLD01-27
6441Z-EHP01-23 6441Z-EHP01-23
6441Z-EHP01-21
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
Z
-E H
P -2
Z
-E H
P -2
T1
6441Z-EHP01-23
J
J
6441Z-EHP01-23
6441Z-EHP01-23
282828
6441Z-EHP01-21
U
U
6441Z-EHP01-21
JJJ
J
J J
J
6441Z-EHP01-21
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-236441Z-EHP01-23
6441Z-EHP01-23
Z
-E H
P -2
Z
-E H
P -2
Z
-E H
P -2
OS
OS
PNL 6441Z-EHP01-23
GENERAL NOTES
SHEET NOTES
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND WIRES IS
NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO THE
EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND INSTALL
BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND JUNCTION
BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR SHALL PROVIDE
CONDUITS AND WIRES MEETING NEC AND VAMC REQUIREMENTS,
UNLESS OTHERWISE NOTED.
LIGHT SWITCHES MOUNTED 48" AFF, UNLESS OTHERWISE INDICATED.
CIRCUIT NUMBERS WITHOUT IDENTIFICATION ARE FROM PNL
6441Z-NHD01 OTHERS ARE PRECEDED BY PANEL IDENTIFICATION.
OCCUPANCY SENSOR QUANTITY AND LOCATION SHOWN IS FOR
REFERENCE ONLY. PROVIDE OCCUPANCY SENSORS TO COMPLETELY
COVER THE AREA WHERE OCCUPANCY SENSORS ARE INSTALLED.
PROVIDE T-BAR SAFETY EARTHQUAKE CLIP ON LIGHT FIXTURE,
WHENEVER POSSIBLE.
WHERE CEILINGS ARE INSULATED, PROVIDE IC RATED LIGHTING
FIXTURE WHETHER OR NOT IC RATING IS CALLED OUT ON FIXTURE
SCHEDULE OR DRAWINGS. IC RATED FIXTURE TYPE AND APPEARANCE
SHALL MATCH NON-RATED FIXTURE TYPE AS SHOWN ON FIXTURE
SCHEDULE. SUBMIT NEW IC RATED FIXTURE TYPE TO COR OR VAMC
REPRESENTATIVE FOR APPROVAL.
OCCUPANCY SENSOR AND OCCUPANCY WALL SWITCH SHALL BE DUAL
TECHNOLOGY TYPE, UNLESS OTHERWISE INDICATED.
1.
2.
3.
4.
1 TYPE "U" EXT. WALL LAMPS MOUNTED 12' A.F.F. ALONG EAST BUILDING
WALL
TYPE "U" EXT. WALL LAMPS MOUNTED 8' A.F.F.
MOUNTED ±9'-0" A.F.F.
ALL FIRST FLOOR LIGHTING NOT MARKED OTHERWISE OR NOT MARKED
FOR EMERGENCY LIGHTING IS FED FROM PNL
6441Z-NHD01, CIRCUIT 26
ALL EXIT AND STAIRWAY LIGHTS ON PNL 6441Z-EHP01, CKT 23
ALL EMERGENCY LIGHTS IN ROOMS ARE ON PNL 6441Z-EHP01, CKT 23.
ALL EMERGENCY LIGHTS IN CORRIDORS ARE ON PANEL 6441Z-EHP01,
CKT 23.
ALL LIGHTING IN ELECTRICAL , MECHANICAL AND TELECOM ROOMS ARE
ON PANEL 6441Z-EHP01, CKT. 23.
ALL EXTERNAL LIGHTING IS PHOTO CONTROLLED FROM ROOF, AS
SHOWN ON DWG NO. EP133.
SEE TELECOM DRAWING ON LIGHT LOCATION REQUIREMENTS.
TYPE "U" EXT. WALL LAMPS MOUNTED 6' A.F.F.
5.
6.
7.
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:41 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EL111-1
ELECTRICAL LIGHTING PLAN -
ENLARGED FIRST FLOOR - NORTH
A. LEUNG
612-501
E. MITCH
118 151
1/4" = 1'-0"EL111-1
1 ELECTRICAL LIGHTING PLAN - PARTIAL FIRST FLOOR - NORTH PROJECT
NORTH
DDDDDDD
D
D
D
D D D D D DD
D D
D
3D3D
3D 3D
DDDD
D
D
3D 3D
GENERAL NOTES
SHEET NOTES
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND WIRES
IS NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO THE
EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND INSTALL
BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND JUNCTION
BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR SHALL
PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
LIGHT SWITCHES MOUNTED 48" AFF, UNLESS OTHERWISE INDICATED.
CIRCUIT NUMBERS WITHOUT IDENTIFICATION ARE FROM PNL
6441Z-NHD01; OTHERS ARE PRECEDED BY PANEL IDENTIFICATION.
OCCUPANCY SENSOR QUANTITY AND LOCATION SHOWN IS FOR
REFERENCE ONLY. PROVIDE OCCUPANCY SENSORS TO COMPLETELY
COVER THE AREA WHERE OCCUPANCY SENSORS ARE INSTALLED
PROVIDE T-BAR SAFETY EARTHQUAKE CLIP ON LIGHT FIXTURE,
WHENEVER POSSIBLE.
WHERE CEILINGS ARE INSULATED, PROVIDE IC RATED LIGHTING
FIXTURE WHETHER OR NOT IC RATING IS CALLED OUT ON FIXTURE
SCHEDULE OR DRAWINGS. IC RATED FIXTURE TYPE AND
APPEARANCE SHALL MATCH NON-RATED FIXTURE TYPE AS SHOWN
ON FIXTURE SCHEDULE. SUBMIT NEW IC RATED FIXTURE TYPE TO
COR OR VAMC REPRESENTATIVE FOR APPROVAL.
OCCUPANCY SENSOR AND OCCUPANCY WALL SWITCH SHALL BE
DUAL TECHNOLOGY TYPE, UNLESS OTHERWISE INDICATED.
1.
2.
3.
4.
5.
6.
7.
1 TYPE "U" EXT. WALL LAMPS FACING EAST WALKWAY MOUNTED ±12'
A.F.F.
TYPE "U" EXT. WALL LAMPS MOUNTED ±1'-0" ABOVE DOOR
DECORATIVE RESIN PANEL AND ASSOCIATED STRIP LIGHTING
FIXTURES AND THE SURROUNDING SOFFIT DOWNLIGHTS, ARE TO BE
CENTERED ON POINT OF INTERSECTION OF OVERHEAD BEAMS.
ALL 1ST FLOOR LIGHTING NOT MARKED OTHERWISE OR NOT
MARKED FOR EMERGENCY LIGHTING IS FED FROM PANEL
6441Z-NHD01, CIRCUIT 26
ALL EXIT AND STAIRWAY LIGHTS ON PNL 6441Z-EHP01, CKT. 23
ALL EMERGENCY LIGHTS IN ROOMS AND TOILET ARE ON
PNL 6441Z-EHP01, CKT. 23
ALL EMERGENCY LIGHTS IN CORRIDORS ARE ON PANEL
6441Z-EHP01, CKT. 23
COORDINATE WITH ELEVATOR MANUFACTURER ON ELEVATOR PIT
LIGHTS AND SWITCH MOUNTING HEIGHT AND LOCATION.
ELEVATOR PIT LIGHTS ARE ON PNL 6441Z-EHP01, CKT. 23
81 SF
ELEVATOR
E1
OS
ab a a a a b a b aaa
C1
C1C1C1C1
D1 D1
D1 D1
D1
D1
N
D1 D1 D1
D2
D2 D2 D2
D2D2 D1
C1
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
B2 B2
B2 B2
M
M
UUU
M A
T C
H L
IN
E S
E E
E L -1
10'-0" A.F.F.
/2 "6' - 0"6' - 0"
OF LTDOORSOF LT
M A
T C
H L
IN
E S
E E
E L -1
F
M
6' - 0"6' - 0"
4' - 0" 4' - 0"
/8
M M
H
1193 SF
OPEN OFFICE
1A02
174 SF
PHOTO
1A13
56 SF
STAFF
1A02D
63 SF
STAFF
1A02C
801 SF
WAITING
1A01
210 SF
RECEPTION
1A03
36 SF
H.A.C.
1AC2A
847 SF
CORRIDOR
1AC2
126 SF
EXAM
ROOM
1A04125 SF
EXAM
ROOM
1A05
122 SF
EXAM
ROOM
1A06
124 SF
EXAM
ROOM
1A07
124 SF
EXAM
ROOM
1A08
124 SF
EXAM
ROOM
1A09
124 SF
EXAM
ROOM
1A10
63 SF
PATIENT
TOILET
1AC2C
75 SF
SHOWER
1A13A
354 SF
STAFF
1AC2B
58 SF
PUBLIC
TOILET
1AC1A
59 SF
PUBLIC
TOILET
1AC1B
179 SF
HALL
1AC1
LIGHT SWITCHES ON
RECEPTION STALLS TO BE
MOUNTED UNDER THE
COUNTER FOR EACH OF 3
STATIONS
1 (TYP.)
A1
0.9122.135
A
B
C
D
C4
D1
3.1
(TYP.)
T1
L
L
L
L
L
L
PHOTOCELL
CIRCUIT "c", ON ROOF
MM
C1
OSOS OS
a b
A1
A1 A1
A2
A2
A1
A2 A2 A2
A2
A2
A1 A1 A1 A1
K
K
K
K
K
K
K
K
D1 D1
M
NN
A1 A1
A1A1
PHOTOCELL
CIRCUIT "a", ON ROOF
PHOTOCELL
CIRCUIT "c", ON ROOF
(TYP)
4 (TYP)
6 (TYP)
G
G b
T 5
6 (TYP.)
4 (TYP.)
aaa
4 (TYP.)
6 (TYP.)
c cc c
T1
T1
T1
T1
T1
T1
T1
T2
T1
(TYP)
N
N
N
N
N
N
26 26 26
26 26 26
26OS OS
OS
G
G
26 26
26 26
26 26
26 26
G
G
2626262626
26 26
(TYP)
26 26 26
(TYP)
U
6441Z-EHP01-21
T1
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23 6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-236441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-236441Z-EHP01-236441Z-EHP01-236441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23 6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-21
6441Z-EHP01-21
6441Z-EHP01-23
282828
V
V
V
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
26 D1
P
P
6441Z-EHP01-23
6441Z-EHP01-23
6441Z-EHP01-23
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:43 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EL111-2
ELECTRICAL LIGHTING PLAN -
ENLARGED FIRST FLOOR - SOUTH
A. LEUNG
612-501
E. MITCH
119 151
1/4" = 1'-0"EL111-2
1 ELECTRICAL LIGHTING PLAN - PARTIAL FIRST FLOOR - SOUTH PROJECT
D
D
D
D
D
D
D2D2D2
C1 C1
C1 C1
C1 C1
B1B1
L
C1
C1
C1
F1
OS
B1 a a a a a
OS
67 5
A
B
C
D
C4
D1
A.3
A.7
B.3 b a a
C1
C1
C2
C2
N
O S
(TYP.)
b
PHOTO CELL CIRCUIT "c" c c a
PHOTO CELL CIRCUIT "a"
(TYP.)
B1b
(TYP.)
a a b
T1
T1
101 SF
I.T.
2A08
316 SF
IT OPEN
OFFICE
2A05
293 SF
STAFF
2AC2D
80 SF
CLEAN
SUPPLY
2AC2E
370 SF
IT STORAGE
2A06
2 2
OS
2 2
2 22
(TYP)
2 2
6442Z-NHP01,
CKT 2
PNL 6442Z-EHP01, CKT13
a
S
F E
L E
C T
R
IC
A L
A
C E
U
U
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
U
6441Z-NHD01-28
J 6 Z
-E H
P -1
6441Z-EHP01-21
6441Z-EHP01-21
J
J
6442Z-EHP01-13
6442Z-EHP01-13
8 9
6442Z-
EHP01-13
6442Z-EHP01-13
GENERAL NOTES
SHEET NOTES
1 TYPE "U" EXT. WALL LAMPS MOUNTED 8' A.F.F. ABOVE LANDING OR
AFF.
ALL 2ND FLOOR LIGHTING NOT MARKED OTHERWISE OR NOT MARKED
FOR EMERGENCY LIGHTING IS FED FROM PANEL 6442Z-NHP01, CKT 2.
ALL EXTERNAL LIGHTING IS PHOTO CONTROLLED FROM ROOF, AS
SHOWN ON DWG NO EP133 .
ALL EXIT AND STAIRWAY LIGHTS ON PNL FROM 6442Z-EHP01, CKT 13.
ALL EMERGENCY LIGHTS IN ROOMS ARE ON PNL 6442Z-EHP01, CKT. 13.
ALL EMERGENCY LIGHTS IN CORRIDORS ARE ON PANEL 6442Z-EHP01,
CKT 13.
ALL LIGHTING IN ELECTRICAL, MECHANICAL AND TELECOM ROOMS
ARE ON PANEL 6442Z-EHP01, CKT. 13.
MOUNTED ±9'-0" AFF.
SEE TELECOM DRAWING ON LIGHT LOCATION REQUIREMENTS.
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND WIRES
IS NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO THE
EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND INSTALL
BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND JUNCTION
BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR SHALL
PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
LIGHT SWITCHES MOUNTED 48" AFF, UNLESS OTHERWISE INDICATED.
CIRCUIT NUMBERS WITHOUT IDENTIFICATION ARE FROM PNL
6441Z-NHP01 OTHERS ARE PRECEDED BY PANEL IDENTIFICATION.
OCCUPANCY SENSOR QUANTITY AND LOCATION SHOWN IS FOR
REFERENCE ONLY. PROVIDE OCCUPANCY SENSORS TO COMPLETELY
COVER THE AREA WHERE OCCUPANCY SENSORS ARE INSTALLED.
PROVIDE T-BAR SAFETY EARTHQUAKE CLIP ON LIGHT FIXTURE,
WHENEVER POSSIBLE.
WHERE CEILINGS ARE INSULATED, PROVIDE IC RATED LIGHTING
FIXTURE WHETHER OR NOT IC RATING IS CALLED OUT ON FIXTURE
SCHEDULE OR DRAWINGS. IC RATED FIXTURE TYPE AND
APPEARANCE SHALL MATCH NON-RATED FIXTURE TYPE AS SHOWN
ON FIXTURE SCHEDULE. SUBMIT NEW IC RATED FIXTURE TYPE TO
COR OR VAMC REPRESENTATIVE FOR APPROVAL.
OCCUPANCY SENSOR AND OCCUPANCY WALL SWITCH SHALL BE
DUAL TECHNOLOGY TYPE, UNLESS OTHERWISE INDICATED.
1.
2.
3.
4.
5.
6.
7.
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:45 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EL112-1
ELECTRICAL LIGHTING PLAN -
ENLARGED SECOND FLOOR PLAN -
NORTH
A. LEUNG
612-501
E. MITCH
120 151
1/4" = 1'-0"EL112-1
1 ELECTRICAL LIGHTING PLAN - PARTIAL SECOND FLOOR PLAN - NORTH TRUE
NORTH
M A
T C
H L
IN
E
S E
E E
L -2
M A
T C
H L
IN
E
S E
E E
L -2
.E
.C
F.E.C.
D
D D
D
D D D D
D
DDD
D D
D
D D
3D 3D
3D 3D
D
D D
3D3D
D
DD
A
B
D2
D2
B2
D2
D2 D2
D2 D2
D2
D2
B1
D1
D2
D2
B2
D2
D2 D2
B1 B1 B1 B1
B1
B1
C1C1
B1
B1 B1
A2 A2 A2A2
A2A2A2A2
A2A2
A2A2
A2A2
B2B2
B2 B2
B2 B2
D1 D1
D2 D2
C1
C1
C1
M
316 SF
IT OPEN
OFFICE
2A05
103 SF
OFFICE
2A05A
99 SF
MULTI
PURPOSE
2A05B
262 SF
CONFERENCE
2A04
214 SF
LOUNGE
2A03
1078 SF
CORRIDOR
2AC1
183 SF
WOMEN'S
TOILET
2AC1B
370 SF
IT STORAGE
2A06
67 SF
PATIENT
TOILET
2AC2C
631 SF
CORRIDOR
2AC2
175 SF
GEN
PROCEDURE
2A13
172 SF
DERM LAB
2A12
174 SF
GEN
PROCEDURE
2A11
175 SF
GEN
PROCEDURE
2A10
120 SF
PROCEDURE
PREP
2A09
240 SF
PROCEDURE
WAITING
2A01
370 SF
CONFERENCE
2A02
19 SF
TANK STO.
2AC2A
81 SF
DIRTY
2AC2B
B1
C2
O S
SHAFT
OS
OS
C.18'-0" AFF
C.25'-0" AFF
ALL 8 IN
SAME PLANE
OS
OS
C1
OS
M A
T C
H L
IN
E
S E
E E
L -1
M A
T C
H L
IN
E
S E
E E
L -1
C1
0.9122.135
A
B
C
D
C4
D1
3.1
B1 B1
OS
B1
B1
B1
B1
B1
B1
B1
B1
B1
OS
B1
OS
M
OS
B1B1B1B1
B1
OSOS
OS
C2
OS
F
G
G49 SF
HAC
T T
(TYP)
(TYP)
(TYP)6
(TYP)
(TYP)
7 (TYP)
(TYP)
(TYP)
G
L G G
LL
L L
T1 T1
T1
T1
T1
T2
T1
T1
F
N
OS
2 2
2 2
2 2
2 2 2
2 2
TO LIGHTS
ON ROOF
OS
(TYP)
O S
O S
(TYP)
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
V V
V
6442Z-EHP01-136442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-136442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13 6442Z-EHP01-13
6442Z-EHP01-13
6442Z-EHP01-13
GENERAL NOTES
SHEET NOTES
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND WIRES
IS NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO THE
EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND INSTALL
BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND JUNCTION
BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR SHALL
PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
LIGHT SWITCHES MOUNTED 48" AFF, UNLESS OTHERWISE INDICATED.
CIRCUIT NUMBERS WITHOUT IDENTIFICATION ARE FROM PNL
6442Z-NHP01 OTHERS ARE PRECEDED BY PANEL IDENTIFICATION.
OCCUPANCY SENSOR QUANTITY AND LOCATION SHOWN IS FOR
REFERENCE ONLY. PROVIDE OCCUPANCY SENSORS TO COMPLETELY
COVER THE AREA WHERE OCCUPANCY SENSORS ARE INSTALLED.
PROVIDE T-BAR SAFETY EARTHQUAKE CLIP ON LIGHT FIXTURE,
WHENEVER POSSIBLE.
WHERE CEILINGS ARE INSULATED, PROVIDE IC RATED LIGHTING
FIXTURE WHETHER OR NOT IC RATING IS CALLED OUT ON FIXTURE
SCHEDULE OR DRAWINGS. IC RATED FIXTURE TYPE AND APPEARANCE
SHALL MATCH NON-RATED FIXTURE TYPE AS SHOWN ON FIXTURE
SCHEDULE. SUBMIT NEW IC RATED FIXTURE TYPE TO COR OR VAMC
REPRESENTATIVE FOR APPROVAL.
OCCUPANCY SENSOR AND OCCUPANCY WALL SWITCH SHALL BE DUAL
TECHNOLOGY TYPE, UNLESS OTHERWISE INDICATED.
1.
2.
3.
4.
5.
6.
7.
1 ELEVATOR HOIST LIGHT IS ON PNL 6442Z-EHP01, CKT 13
ALL 2ND FLOOR LIGHTING NOT MARKED OTHERWISE OR MARKED
FOR EMERGENCY LIGHTING IS FED FROM PANEL 6442Z-NHP01, CKT 2.
ALL EXTERNAL LIGHTING IN PHOTO CONTROLLED FROM ROOF, AS
SHOWN ON DWG. NO. EP133.
NOT USED
ALL EXIT AND STAIRWAY LIGHTS ON PNL 6442Z-EHP01, CKT 13.
ALL EMERGENCY LIGHTS IN ROOMS ARE ON PNL 6442Z-EHP01, CKT 13.
ALL EMERGENCY LIGHTS IN CORRIDORS ARE ON PANEL 6442Z-EHP01,
CKT 13.
COORDINATE WITH ELEVATOR MANUFACTURER ON ELEVATOR HOIST
LIGHTS AND SWITCH MOUNTING HEIGHT AND LOCATION.
ROOF LIGHT SWITCH, PROVIDE PERMANENT LABEL ON SWITCH "ROOF
LIGHT SWITCH"
MOUNTED NEXT TO ROOF ACCESS LADDER, ±48".
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
3/13/2018 9:03:48 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EL112-2
ELECTRICAL LIGHTING PLAN -
ENLARGED SECOND FLOOR PLAN -
SOUTH
A. LEUNG
612-501
E. MITCH
121 151
1/4" = 1'-0"EL112-2
1 ELECTRICAL LIGHTING PLAN - PARTIAL SECOND FLOOR PLAN - SOUTH PROJECT
R
R
R
R4
R
R
2 3
PNL 6442Z-NHP01, CKT4
R 4
R
P
P
P
R
AHU
EF
EF
EF
AHU
CU
CU
CU
CU
AHU
CU
GENERAL NOTES
SHEET NOTES
1.
2.
3.
4.
5.
6.
7.
1 MOUNTED ON TOP OF MECHANICAL SCREEN FRAME. PROVIDE
MOUNTING BRACKET.
PROVIDE WALL MOUNTING BRACKET
MOUNTED ± 6" BELOW TOP OF WALL
AIM FIXTURE TO ENSURE FIXTURE DOES NOT INTERFERE WITH
PHOTOCELL OPERATION
TO SWITCH DOWN BELOW
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND WIRES
IS NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO THE
EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND INSTALL
BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND JUNCTION
BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR SHALL
PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
MINIMUM WIRE SIZE SHALL BE AWG #12 FOR POWER AND AWG #14
FOR CONTROL.
ALL OUTDOOR ELECTRICAL CONDUITS SHALL BE RGS. CONDUIT
WHICH LIES ON THE ROOF TOP SHALL BE MOUNTED ON CHANNEL
PLASTIC/RUBBER SUPPORT, COOPER B-LINE DURA-BLOCK D8 SERIES
OR EQUAL,
ALL OUTDOOR ELECTRICAL EQUIPMENT SHALL BE IN NEMA 3R
ENCLOSURES, UNLESS OTHERWISE NOTED.
ROUTE CONDUITS BELOW ROOF AND PENETRATE THRU ROOF AT
EQUIPMENT LOCATION.
PANEL D2-NH ARE LOCATED IN THE SECOND FLOOR ELECTRICAL
ROOM 2AC1E
ALL ROOF LIGHTS ARE ON PNL 6442Z-NHP01, CKT 4
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:49 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EL113
ELECTRICAL LIGHTING PLAN -
ROOF
A. LEUNG
612-501
E. MITCH
122 151
1/4" = 1'-0"EL113
1 ELECTRICAL LIGHTING PLAN - ROOF PROJECT
GENERAL NOTES
UNDERGROUND RING SHALL BE #4/0 AWG, BARE COPPER WIRE. NOT
LESS THAN 30" BELOW GRADE, UNLESS OTHERWISE NOTED.
PIGTAIL SHALL BE #2/0 AWG, BARE COPPER WIRE.
GROUND RING SHALL BE A MINIMUM 4 FEET ALL AROUND BUILDING
PERIMETER, UNLESS OTHERWISE NOTED.
SLEEVE ALL GROUND WIRE STUB UP OUT OF CONCRETE.
ALL EQUIPMENT UNDER THIS PROJECT WHETHER OR NOT SHOWN
SHALL BE GROUNDED IN STRICT CONFORMANCE WITH NEC.
GROUND WIRE ROUTING IS FOR REFERENCE. CONTRACTOR IS TO
SELECT THE BEST ROUTING BASED ON FIELD CONDITIONS.
COORDINATE WITH SMUD ON CONDUITS BURIAL AND DEPTH
REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE FOR ALL WORK AND COSTS TO BRING
UTILITY POWER TO THE BUILDING.
ANY GROUND CONNECTION THAT IS NOT THERMOWELDED SHOULD BE
ACCESSIBLE, IF POSSIBLE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
SHEET NOTES
1 GROUND ROD AND WELL, 3/4" X 10'-0" COPPER CLAD STEEL, NUMBER
AS REQUIRED. SEE DETAIL 11/ED803.
GROUND CONNECTION TO METALLIC PIPES. PROVIDE MEANS TO
PREVENT ELECTROLYTIC ACTION. USE BRONZE, TINNED BRONZE, BI-
METAL LUGS, CLAMPS, CONNECTORS, ETC.
BARE COPPER WIRE, #4/0 TYPICAL, DIRECT BURIED MINIMUM 30"
BELOW GRADE.
EXOTHERMIC WELD.
TO TELECOM ROOM GROUNDING BAR.
GROUND CONNECTION TO BUILDING STEEL. PROVIDE MEANS TO
PREVENT ELECTROLYTIC ACTION. USE BRONZE, TINNED BRONZE, BI-
METAL LUGS, CLAMPS, CONNECTORS, ETC.
TO ELECTRICAL ROOM GROUNDING BAR.
#4/0 AWG BARE COPPER WIRE TO GROUND BAR.
EXTEND GROUND WIRE TO 2ND FLOOR GROUNDING BAR. PROVIDE
METALLIC CONDUIT FOR GROUND WIRE MECHANICAL PROTECTION.
GROUND WIRE FOR FUTURE CONNECTION TO EYE CLINIC GROUNDING
SYSTEM.
CONTRACTOR TO DETERMINE LOCATION FOR STUB-UP FOR FUTURE
CONNECTION BASED ON FIELD CONDITIONS. MARK LOCATION FOR
FUTURE DISCOVERY.
BRING CONDUITS UP TO SERVICE CABINET PER NEC AND
MANUFACTURERS CONFIGURATION.
BRING CONDUIT UP TO TRANSFORMER PAD IN ACCORDANCE WITH
SMUD REQUIREMENTS.
INSTALL TWO (2) EACH FOUR (4) INCH SCHEDULE 40 PVC CONDUITS 60
INCHES BELOW GRADE FROM SMUD VAULT TO TRANSFORMER PAD IN
ACCORDANCE WITH SMUD SPECIFICATIONS. COORDINATE WITH SMUD
INSPECTOR.
GROUND BAR IN NEMA 3R WIREWAY. PROVIDE CONDUIT FOR
MECHANICAL PROTECTION ON ABOVE GROUND WIRING
REROUTE CONDUITS/TRENCH AS NECESSARY TO AVOID FOOTINGS
AND PIERS.
PVC ENCASED IN CONCRETE.
NOT USED.
DIRECT BURIAL WITHOUT CONDUIT.
PROTECT AND MARK FOR FUTURE DISCOVERY.
MINIMUM DEPTH 60".
MINIMUM CLEARANCE 42".
CONDUITS FOR FUTURE EYE CLINIC SEE DRAWING EP134 AND SINGLE
LINE DRAWING EP601.
COORDINATE WITH SMUD ON SMUD TRANSFORMER GROUNDING
REQUIREMENTS. PROVIDE GROUND AND GROUND ROD PER SMUD
REQUIREMENTS.
CONTRACTOR IS TO FIELD DETERMINE THE CONDUITS/TRENCH
ROUTING TO ENSURE THERE IS LESS THAN 360º TURNS PER NEC
REQUIREMENTS.
EXISTING UTILITY ELECTRICAL CIRCUIT.
GROUND CONNECTION TO GATE.
LEGEND
UNDERGROUND CONDUCTORS
PIGTAIL
EXOTHERMIC WELD
GROUND ROD AND WELL
.0
FUTURE EYE
CLIN
IC
LOCATIO
N
PROPOSED D
ERMATOLOGY
OUTPATIENT BUILDIN
G
EX. B
LDG
. 6
EX. B
LDG
. 6
E
HOSPITAL WAY
INSTALL
6" FIRE
SERVICE
8" W A
T E R
CONNECT TO
(E) 8" WATER
LINE
CONNECT TO
(E) 8" WATER
LINE
" W
A T E
R
8" W
ATER
FIRE HYDRANT
4" DOMESTIC WATER
4" BFP
3" DW
3" DW
STUB OUT
NEW
LOCATION
OF (E) BFP
8" WATER
ELECTRICAL
VAULT (E)
E E E
E
E
E
EEEE
S D
M H
S D
M H
S
S
S
S
S
S
S
S
S
S
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
W
W
W
WW
W
WWW
W
W
W
W
W
W
W
W
W
W
NEW TRANSFORMER
PAD FOR UTILITY
TRANSFORMER
(N) SMUD
SERVICE
CABINET
2 EA 4" SCH. 40 PVC
CONDUIT ENCASED
IN CONCRETE
5 SETS OF 4# 500 KCMIL & 1# 250
KCMIL GND IN 5 EA 4" SCH. 40
+ 1-4" SCH 40 SPARE
. 22
FUTURE EYE CLINIC 1ST FLOOR
ELECTRICAL ROOM
3 10
11 19 20
3 10 11
19 20
GND
GND
GND
GND
GND
TYP.
G N
D
TYP.
W
W
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:51 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EP120
ELECTRICAL POWER AND
GROUNDING SITE PLAN
A. LEUNG
612-501
E. MITCH
123 151
1" = 10'-0"EP120
4 ELECTRICAL POWER AND GROUNDING SITE PLAN TRUE
UP
.E
.C
G F
C I
GFCIGFCI
G F
C I
G F
C I
G F
C I
G F
C I
J
G F
C I
G F
C I
GFCI
GFCI
J
GFCI
GENERAL NOTES
SHEET NOTES
1.
2.
3.
4.
5.
6.
7.
1 PROVIDE GROUNDING BAR AND GROUND CONNECTION.
MOUNT SIX (6) QUAD OUTLETS ON OVERHEAD CABLE TRAY AND RUN
THREE (3) CONDUITS WITH DUAL CIRCUITS IN EACH ONE. (4 EACH ON
EMERGENCY POWER AND 2 EACH NORMAL POWER) SEE TELECOM
DRAWINGS FOR DETAILS.
PROVIDE 2" X 4" JUNCTION BOX AND 3/4" CONDUIT. TERMINATE
CONDUIT 6" ABOVE CEILING. CAP & SEAL.
RECEPT TYPE SHOWN IS FOR REFERENCE. COORDINATE WITH VAMC
ON SPECIAL RECEPTACLE REQUIREMENTS.
20A RECEPTACLES ON OVERHEAD CABLE TRAY.
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND WIRES
IS NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO THE
EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND INSTALL
BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND JUNCTION
BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR SHALL
PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
ALL CONDUITS SHALL BE CONCEALED IN ACCORDANCE WITH
SPECIFICATION SECTION 26 05 33. CONDUITS SHALL RUN ABOVE THE
CEILING OR WITHIN FINISH WALLS, UNLESS OTHERWISE NOTES.
OPPOSING RECEPTACLES (BACK TO BACK) SHALL BE SPACED
MINIMUM 12" APART AND NOT IN SAME STUD BAY.
TELECOMMUNICATION RECEPTACLE AND POWER RECEPTACLE SHALL
BE A MINIMUM OF 6" APART.
CIRCUIT NUMBERS WITHOUT IDENTIFICATION ARE FROM PANEL
6441Z-NLD01 AND 6441Z-NLD02 OTHERS ARE PROCEEDED BY PANEL
IDENTIFICATION.
LASER ROOM AND EXAM ROOM SEE EP402 FOR DETAIL.
ELECTRIC RECEPTACLES IN IT ROOM SEE IT DRAWINGS FOR
REQUIREMENT.
225 SF
ELECTRICAL
1A15
710 SF
MECHANICAL
1A14
108 SF
MULTI
PURPOSE
1A02B
100 SF
I.T.
1A16
1193 SF
OPEN OFFICE
1A02
102 SF
OFFICE
1A02A
170 SF
LASER
1A12
123 SF
EXAM
ROOM
1A11
124 SF
EXAM
ROOM
1A10
847 SF
CORRIDOR
1AC2
M A
T C
H L
IN
E
S E
E E
P -2
M A
T C
H L
IN
E
S E
E E
P -2
WP
-A
WP
WP
WP
A
B
C
D
C4
D1
A.3
A.7
B.3
-B
55 55 55
PNL 6441Z-ELP01, CKT 1
PNL 6441Z-NLD02, CKTS 43,45,47
PNL 6441Z-NLD02,
CKTS 51,53,55
6441Z-ELP01-18
PNL 6441Z-ELP01,
CKT 23,29
PNL 6441Z-NLD02, CKT 84
31,33 Y4
PNL 6441Z-NLD01, CKT 31,33,35,37,39,41
(TYP OF 6)
6441Z-ELP01-12
6441Z-ELP01-7
6441Z-ELP01-3
6441Z-ELP01-5
49 81
6441Z-ELP01-17
6441Z-ELP01-21
6441Z-
ELP01-23
6441Z-ELP01-29
PNL 6441Z-ELP01, CKTS 7,12,18
PNL 6441Z-NLP02, CKT 49,81
PNL 6441Z-ELP01, CKT 17,21
PNL 6441Z-ELP01,
CKT 3,5
6441Z-ELP01-1
6441Z-ELP01-1
6441Z-ELP01-1
6441Z-ELP01-1
-A
-A
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:52 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EP121-1
ELECTRICAL FIRST FLOOR
ENLARGED POWER PLAN - NORTH
A. LEUNG
612-501
E. MITCH
124 151
PROJECT
NORTH
1/4" = 1'-0"EP121-1
1 ELECTRICAL FIRST FLOOR ENLARGED POWER PLAN - NORTH
UP
JJ
J
J
G F
C I
G F
C I
G F
C I
G F
C I
G F
C I
J
J
J
J
G F
C I
G F
C I
G F
C I
GFCI
G F
C I
J
JJ
JJ
JJ
J
JJJJJJ
JJ JJ
G F
C I
GFCI
ELEVATOR
E1
1193 SF
OPEN OFFICE
1A02
63 SF
STAFF
1A02C
56 SF
STAFF
1A02D 34 SF
ELEVATOR
CONTROL
1A01A
801 SF
WAITING
1A01
179 SF
HALL
1AC1
210 SF
RECEPTION
1A03
36 SF
H.A.C.
1AC2A
59 SF
PUBLIC
TOILET
1AC1B
58 SF
PUBLIC
TOILET
1AC1A
354 SF
STAFF
1AC2B
63 SF
PATIENT
TOILET
1AC2C
75 SF
SHOWER
1A13A
174 SF
PHOTO
1A13
124 SF
EXAM
ROOM
1A10
124 SF
EXAM
ROOM
1A09
124 SF
EXAM
ROOM
1A08
124 SF
EXAM
ROOM
1A07
122 SF
EXAM
ROOM
1A06
125 SF
EXAM
ROOM
1A05
126 SF
EXAM
ROOM
1A04
STAIR 2
S2
847 SF
CORRIDOR
1AC2
WP
0.9122.135
A
B
C
D
C4
D1
3.1
WP
GFCI
GFCI
WP
- B
GFCI
- B
- B
GFCI GFCI
- A
GFCI
- B
GFCI
- B
GFCI
- B
GFCI
- B
GFCI
WP
676563
GFCI
74 74
SC
SC
SC
SC
SC70
SC
-H
-H
TV
(TYP)(TYP)
626464
6441Z-
ELP01-9
565654 54
-B
6441Z-ELP01-15
GFCI
IN ELEVATOR PIT
12" B.F.F.
TO TOP OF ELEVATOR
HOISTWAY
PNL 6441Z-NLD02, CKT 48,50,52
-A-A
PNL 6441Z-NLD02, CKT 69,71,75
333333
GFCI
PNL 6441Z-NLD01, CKT 36
PNL 6441Z-NLD02, CKT 78
PNL 6441Z-NLD02, CKT 63,65,67
PNL 6441Z-NLD02, CKT 57,59,61
ED801
PNL 6441Z-NLD02, CKT 60,68,76
PNL 6441Z-NLD02, CKT 62,64,66
46 48 48 50 50 52 52
6441Z-ELP01-9
Y
39,41
35,37
5 6
F A
C U
PNL 6441Z-ELP01, CKT 4
PNL 6441Z-NLD02, CKT 70,72,74
PNL 6441Z-ELP01, CKT 9,11,15
PNL 6441Z-NLD02, CKT 54,56,58
PNL 6441Z-NLD02, CKT 44,46
6441Z-
ELP01-116441Z-
ELP01-11
12,14
PNL 6441Z-NLD01, CKT 12,14
N S
PNL 6441Z-ELP01, CKT 10
-A
-A
-A-A-A-A-A-A
PNL 6441Z-NLD02, CKT 82
-A
GENERAL NOTES
SHEET NOTES
1.
2.
3.
4.
5.
6.
PROVIDE 2" X 4" J BOX AND WIRE WHIP TO SUPPLY POWER TO
MODULAR FURNITURE UNITS IN OPEN OFFICE AND STAFF. MOUNT J
BOX ±18" AFF. COORDINATE WITH COR ON WIRE WHIP
REQUIREMENTS AND LENGTH.
PROVIDE RECEPTACLE NEXT TO TV CABLE OUTLET. MTD AT
HEIGHT SUITABLE FOR TV.
PROVIDE 2" X 4" J BOX AND 3/4" CONDUIT. FOR VAMC FUTURE USE
TERMINATE CONDUIT 6" ABOVE CEILING. CAP AND SEAL.
LIFT BATTERY CHARGER MOUNTED AT A LOCATION SUITABLE FOR
THE LIFT. COORDINATE WITH COR ON EXACT LOCATION.
RECEPT TYPE SHOWN IS FOR REFERENCE. COORDINATE WITH
VAMC ON SPECIAL RECEPTACLE REQUIREMENTS.
30A, 120/208V, 4 POLE, 5 WIRE GROUNDING, TWIST-LOCK
RECEPTACLE.
ELEVATOR POWER AND TELECOM CONNECTION SEE DETAIL
11/ED801.
NURSE CALL STATION AND CONSOLE. SEE IT DRAWING FOR
REQUIREMENTS.
RECEPTACLE FOR KIOSK.
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND
WIRES IS NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO
THE EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND
INSTALL BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND
JUNCTION BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR
SHALL PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
ALL CONDUITS SHALL BE CONCEALED IN ACCORDANCE WITH
SPECIFICATION SECTION 26 05 33. CONDUITS SHALL RUN ABOVE THE
CEILING OR WITHIN FINISH WALLS, UNLESS OTHERWISE NOTES.
OPPOSING RECEPTACLES (BACK TO BACK) SHALL BE SPACED
MINIMUM 12" APART AND NOT IN THE SAME STUD BAY.
TELECOMMUNICATION RECEPTACLE AND POWER RECEPTACLE
SHALL BE A MINIMUM OF 6" APART.
CIRCUIT NUMBERS WITHOUT IDENTIFICATION ARE FROM PANEL
6441Z-NLD01 AND 6441Z-NLD02 OTHERS ARE PROCEEDED BY PANEL
IDENTIFICATION.
PHOTO ROOM AND EXAM ROOM SEE EP402 FOR DETAIL.
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:54 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EP121-2
ELECTRICAL FIRST FLOOR
ENLARGED POWER PLAN - SOUTH
A. LEUNG
612-501
E. MITCH
125 151
1/4" = 1'-0"EP121-2
1 ELECTRICAL FIRST FLOOR ENLARGED POWER PLAN - SOUTH PROJECT
NORTH
M A
T C
H L
IN
E
S E
E E
P -1
M A
T C
H L
IN
E
S E
E E
P -2
J
J
J
J
G F
C I
J
GFCI
101 SF
I.T.
2A08
316 SF
IT OPEN
OFFICE
2A05
73 SF
ELECTRICAL
2AC1E
370 SF
IT STORAGE
2A06
293 SF
STAFF
2AC2D
1078 SF
CORRIDOR
2AC1
M A
T C
H L
IN
E
S E
E E
P -2
M A
T C
H L
IN
E
S E
E E
P -2
A
B
C
D
C4
D1
A.3
A.7
B.3
15 15
PNL 6442Z-NLP01,
CKT 13,15,17
11 11
6442Z-ELP01-29
PNL 6442Z-NLP01, CKT 7,11
WP
PNL 6442Z-ELP01, CKT 29
PNL 6442Z-ELP01, CKT 6,12
6442Z-ELP01-5
PNL 6442Z-NLP01, CKT 1,5,9
80 SF
CLEAN
SUPPLY
2AC2E
6442Z-
ELP01-29
BPSPNL 6442Z-ELP01, CKT 15
WP
6442Z-
ELP01-3 6442Z-ELP01-7
PNL 6442Z-ELP01, CKT 3,5,7
6442Z-ELP01-25
3 34
6442Z-ELP01-2
6442Z-ELP01-4
6442Z-ELP01-6
6442Z-ELP01-12
PNL 6442Z-NLP01, CKT 3,34
PNL 6442Z-ELP01, CKT 2,4
PNL 6442Z-ELP01, CKT 23,25
5 (TYP 6)
6442Z-ELP01-23
GENERAL NOTES
SHEET NOTES
1.
2.
3.
4.
5.
6.
1 PROVIDE 2" X 4" J BOX AND WIRE WHIP TO SUPPLY POWER TO
MODULAR FURNITURE UNITS IN OPEN OFFICE AND STAFF. MOUNT J
BOX ±18" AFF. COORDINATE WITH COR ON WIRE WHIP
REQUIREMENTS AND LENGTH.
PROVIDE GROUNDING BAR AND GROUND CONNECTION.
MOUNT SIX (6) QUAD OUTLETS ON OVERHEAD CABLE TRAY AND RUN
THREE (3) CONDUITS WITH DUAL CIRCUITS IN EACH ONE. (4 EACH ON
EMERGANCY POWER AND 2 EACH NORMAL POWER) SEE TELECOM
DRAWINGS FOR DETAILS.
F/A BOOSTER POWER SUPPLY PANEL.
20A RECEPTACLES ON OVERHEAD CABLE TRAY.
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND WIRES IS
NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO THE
EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND INSTALL
BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND JUNCTION
BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR SHALL
PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
ALL CONDUITS SHALL BE CONCEALED IN ACCORDANCE WITH
SPECIFICATION SECTION 26 05 33. CONDUITS SHALL RUN ABOVE THE
CEILING OR WITHIN FINISH WALLS, UNLESS OTHERWISE NOTES.
OPPOSING RECEPTACLES (BACK TO BACK) SHALL BE SPACED MINIMUM
12" APART AND NOT IN THE SAME STUD BAY.
TELECOMMUNICATION RECEPTACLE AND POWER RECEPTACLE SHALL
BE A MINIMUM OF 6" APART.
CIRCUIT NUMBERS WITHOUT IDENTIFICATION ARE FROM PANEL
6442Z-NLP01 AND 6442Z-NLP02, OTHERS ARE PROCEEDED BY PANEL
IDENTIFICATION.
ELECTRIC RECEPTACLES IN IT ROOM, SEE IT DRAWING FOR
REQUIREMENT.
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:55 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EP122-1
ELECTRICAL SECOND FLOOR
ENLARGED POWER PLAN - NORTH
A. LEUNG
612-501
E. MITCH
126 151
1/4" = 1'-0"EP122-1
1 ELECTRICAL SECOND FLOOR ENLARGED POWER PLAN - NORTH
PROJECT
.E
.C
UP
F.E.C.
J
GFCI
G F
C
IG
F C
I
G F
C I
G F
C I
G F
C I
GFCI
GFCI
J
G F
C I
G F
C I
GFCI
G F
C I
J GFCI
G F
C I
GFCI
J
GFCI
G F
C I
GFCI
J
GFCI
J
G F
C I
G F
C I
G F
C I
GFCI
J
J
J
G F
C I
GFCI
631 SF
CORRIDOR
2AC2
175 SF
GEN
PROCEDURE
2A13
172 SF
DERM LAB
2A12
174 SF
GEN
PROCEDURE
2A11
175 SF
GEN
PROCEDURE
2A10
120 SF
PROCEDURE
PREP
2A09
240 SF
PROCEDURE
WAITING
2A01
188 SF
MEN'S
TOILET
2AC1A
183 SF
WOMEN'S
TOILET
2AC1B
81 SF
DIRTY
2AC2B
19 SF
TANK STO.
2AC2A
67 SF
PATIENT
TOILET
2AC2C
1078 SF
CORRIDOR
2AC1
370 SF
CONFERENCE
2A02
214 SF
LOUNGE
2A03
262 SF
CONFERENCE
2A04
103 SF
OFFICE
2A05A
99 SF
MULTI
PURPOSE
2A05B
316 SF
IT OPEN
OFFICE
2A05
SHAFT
(TYP.)
2A07A
-W
- B
- B - B
- W
- C
WP
- C
0.9122.135
A
B
C
D
C4
D1
3.1
6442Z-ELP01-13
3/4" C. TO AHU-3
AND EF-3 FOR
FUME HOOD
INTERLOCK
SC
SC
SC
SC
SC
SC
-H
PNL 6442Z-NLP01 CKT, 25,27,29
26 26
-H
PNL 6442Z-NLP01,
CKT 24,26,28
PNL 6442Z-NLP01, CKT 30,32
SC
SC
SC
-H
SC
-H
PNL 6442Z-ELP01, CKT 15
VIA ELEVATOR PIT
- H
SC
6442Z-
ELP01-13
X
10,12
PNL 6442Z-NLP01, CKT 2,4,6,8,10,12
X
6,8
6442Z-ELP01-11
6442Z-
ELP01-11
PNL 6442Z-NLP01,
CKT 33,35,37
PNL 6442Z-ELP01, CKT 19,21,23
D2-EL-9
D2-EL-9
X
2,4
PNL 6442Z-ELP01, CKT 9,11,13
11 D2-EL-17
PNL 6442Z-ELP01, CKT 17
PNL 6442Z-NLP01, CKT 14,16,18
D1-EL-15
PNL 6442Z-NLP01, CKT 20,22,31
N S
PNL 6442Z-ELP01, CKT 8
-A-A -A
-A
-A
-W
PNL 6442Z-ELP01, CKT 18
-A
PNL 6442Z-NLP01, CKT 38
PNL 6442Z-NLP01, CKT 18
-W
-W
-W
GENERAL NOTES
SHEET NOTES
1.
2.
3.
4.
5.
6.
1 TV POWER RECEPTACLE MTD NEXT TO TV OUTLET AND SAME
HEIGHT AS TV.
MANUAL RETRACTABLE VIDEO SCREEN.
PROVIDE 2" X 4" J BOX AND WIRE WHIP TO SUPPLY POWER TO
MODULAR FURNITURE UNITS IN OPEN OFFICE AND STAFF. MOUNT J
BOX ±18" AFF. COORDINATE WITH COR ON WIRE WHIP
REQUIREMENTS AND LENGTH.
ELEVATOR RECEPTACLE 12" BELOW OVERHEAD DUCT, IN ELEVATOR
HOISTWAY.
2" X 4" J-BOX AND 3/4" C. TERMINATE 6" ABOVE CEILING CAP & SEAL.
RECEPTACLE FOR PROJECTOR MTD NEXT TO PROJECTOR TELECOM
OUTLET.
RECEPTACLE TYPE SHOWN IS FOR REFERENCE. COORDINATE WITH
COR ON SPECIAL RECEPTACLE REQUIREMENT.
RECEPTACLE FOR KIOSK.
NURSE CALL STATION AND CONSOLE. SEE IT DRAWING FOR
REQUIREMENTS.
RECEPTACLE FOR FUME HOOD.
PROVIDE ALL THE REQUIRED WIRES FOR INTERLOCKING PER
MECHANICAL DRAWINGS AND FUME HOOD MANUFACTURER'S
REQUIREMENTS.
FOR DRINKING FOUNTAIN.
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND WIRES
IS NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER TO THE
EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND INSTALL
BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND JUNCTION
BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR SHALL
PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
ALL CONDUITS SHALL BE CONCEALED IN ACCORDANCE WITH
SPECIFICATION SECTION 26 05 33. CONDUITS SHALL RUN ABOVE THE
CEILING OR WITHIN FINISH WALLS, UNLESS OTHERWISE NOTES.
OPPOSING RECEPTACLES (BACK TO BACK) SHALL BE SPACED
MINIMUM 12" APART AND NOT IN THE SAME STUD BAY.
TELECOMMUNICATION RECEPTACLE AND POWER RECEPTACLE SHALL
BE A MINIMUM OF 6" APART.
CIRCUIT NUMBERS WITHOUT IDENTIFICATION ARE FROM PANEL
6442Z-NLP01 AND 6442Z-NLP02 OTHERS ARE PROCEEDED BY PANEL
IDENTIFICATION.
GEN PROCEDURE, PROCEDURE PREP AND LABORATORY SEE
DRAWING EP402 FOR DETAIL.
S T
A
T E
O F CA L I FORN
I A
EXP.________
E 17641 9-30-2019
R
EG
IS
T
ER
ED
PROFESS IONAL
ENG
IN
E E
RA
U
G
UST I NE K . LEU
N G
E
L E C T R I C A
L
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of02/12/2018
VA MEDICAL CENTER, MATHER, CA 95655
644K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
"FULLY SPRINKLERED"
3/13/2018 9:03:57 AMH:\PROJECTS\VA MEDICAL CENTERS\MATHER - DERMATOLOGY - 10TH SUBMITTAL_vball314.rvt
NEW DERMATOLOGY
OUTPATIENT SERVICES
BUILDING
E. MITCH
EP122-2
ELECTRICAL SECOND FLOOR
ENLARGED POWER PLAN - SOUTH
A. LEUNG
612-501
E. MITCH
127 151
1/4" = 1'-0"EP122-2
1 ELECTRICAL SECOND FLOOR ENLARGED POWER PLAN - SOUTH PROJECT
NORTH
M A
T C
H L
IN
E
S E
E E
P -1
M A
T C
H L
IN
E
S E
E E
P
-1
.E
.C
T
T
T
T
T
T
T
GENERAL NOTES
SHEET NOTES
1.
2.
3.
4.
1 PROVIDE ALL THE REQUIRED WIRES IN CONDUIT BETWEEN T-STATS
AND ASSOCIATED EQUIPMENT, UNLESS OTHERWISE NOTED. SEE
MECHANICAL DRAWING FOR REQUIREMENTS.
PROVIDE 20A 120/277 VAC 2P TOGGLE DISC. SW. MOUNTED IN A
NEMA 1 ENCLOSURE, WITH A PADLOCKABLE FACEPLATE, NEXT TO
UNIT.
PROVIDE EU UNIT DISCONNECT PER MANUFACTURER'S
RECOMMENDATIONS.
NOT USED.
PROVIDE SELF-SUPPORTING FREE-STANDING STAND.
PROVIDED BY EQUIPMENT SUPPLIER.
PROVIDE CONDUIT, POWER, CONTROL AND SIGNAL WIRES PER
MANUFACTURER'S REQUIREMENTS.
SEE DRAWING NUMBER EP133.
PROVIDE ALL POWER, CONTROL AND SIGNAL CONDUITS AND WIRES
PER MANUFACTURER REQUIREMENTS.
PROVIDE CONDUIT AND WIRES FOR CONTROL, AS REQUIRED.
MOUNT NEXT TO CP-1 AT LEAST 4'-0" AFF AND WITHIN REACH OF
CP-1 POWER CORD.
LEGEND
# DOOR NUMBER
AUTOMATIC DOOR OPERATOR
CARD READER
ELECTRIC DOOR STRIKE
POWER SUPPLY
REQUEST TO EXIT DEVICE
DOOR CONTACT SWITCH
SPEED CONTROL UNIT
VARIABLE FREQUENCY DRIVE
WITH DISCONNECT
ADD
CR
ES
PS
RX
D
SC
FOR SIMPLICITY AND CLARITY BRANCH FEEDER CONDUIT AND
WIRES IS NOT SHOWN ON THE DRAWING. ONLY CIRCUIT NUMBER
TO THE EQUIPMENT IS SHOWN. CONTRACTOR SHALL PROVIDE AND
INSTALL BRANCH FEEDER CONDUITS, OUTLET BOXES, WIRE AND
JUNCTION BOXES FOR NEW WIRING INSTALLATION. CONTRACTOR
SHALL PROVIDE CONDUITS AND WIRES MEETING NEC AND VAMC
REQUIREMENTS, UNLESS OTHERWISE NOTED.
ALL CONDUITS SHALL BE CONCEALED IN ACCORDANCE WITH
SPECIFICATION SECTION 26 05 33. CONDUITS SHALL RUN ABOVE
THE CEILING OR WITHIN FINISH WALLS, UNLESS OTHERWISE
NOTED.
PROVIDE ALL REQUIRED CONTROL AND SIGNAL CONDUITS AND
WIRING PER MANUFACTURER'S RECOMMENDATIONS.
ALL DOOR HARDWARE PROVIDED BY OTHERS UNLESS
OTHERWISE NOTED. SEE ACCESS CONTROL DRAWING FOR
REQUIREMENTS.
S T
A
IR
MECHANICAL YARD
M A
T C
H L
IN
E
S E
E E
P -2
M A
T C
H L
IN
E
S E
E E
P -2
102 SF
OFFICE
1A02A
170 SF
LASER
1A12
100 SF
I.T.
1A16
108 SF
MULTI
PURPOSE