36C25919R0007-0002005.pdf
PDF 16 MB Posted
- Attached to
- 436-113 Renovate Primary Care
- Solicitation number
- 36C25919R0007
About this file
36C25919R0007 0002 17.1032-18.07.24 - VA Fort Harrison Bid Submission Set - E-001 - FA103_01.pdf
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
1P
1PH
2/C 2W
3PH
A
AAP
AC
ACC
ACLG
ADO
A/E
AF
AFC
AFF
AFG
AFI
AJH
AHU
AIC
AL
ALT
AMP
APPROX
ARCH
AT
ATS
AUTO
AUX
AV
AWG
BAS
BATT
BC
BD
BFF
BLDG
BMS
BYP
C
CAB
CALC
CAP
CAT
CATV
CB
CCR
CCTV
cd
CD
CF
CKT
CLG
COAX
COMM
CONN
CONST
CONT
CONTR
COORD
CPT
CRI
CT
CTV
CTR
CU
CU FT
dB
DB
DC
DEG C
DEG F
DEMO
DEPT
DIA
DISC
DIST
DN
DS
DT
DWG
EC
EG
ELEC
ELEV
EM
EMI
EMS
EMT
EPO
EQUIP
ESMT
EWC
EWH
EX
EXP
FA
FAAP
FACP
FC
FCU
FIXT
FLR
FLUOR
FU
FUDS
FVR
FVNR
GAL
GALV
GC
GEN
GFI
GND
GRS
GYP BD
HID
HOA
HP
HT
HTR
HV
HVAC
IES
IG
IMC
IR
I/W
IWH
J-BOX
KV
KVA
KVAR
KW
KWH
LED
LF
LM
LRA
LT
LTG
LTNG
LV
MATV
MAX
MC
MCA
MCB
MCC
MDP
MECH
MFR
MFS
MH
MIC
MIN
MISC
MLO
MOA
MSBD
MT
MTS
MTR
NA
NC
NEC
NEMA
NFDS
NIC
NL
NO
NRTL
NTS
OC
OD
OH
OL
PA
PB
PBPU
PCB
PC
PED
PEND
PF
PH
PIV
PNL
PoE
PR
PRI
PROJ
PRV
PT
PVC
PWR
QTY
RCP
RCPT
REQD
RGS
RM
RMS
RTU
SC
SEC
SF
SHT
SI
SIM
S/N
SPEC
SPKR
SP
SR
SS
SSW
STD
SURF
SW
SWBD
SYM
SYS
TC
TEL
TEL/DATA
TERM
TP
TPS
TR
T-STAT
TTB
TTC
TV
TYP
UC
UE
UG
UH
UL
UT
UTP
UTIL
UV
V
VA
VERT
VFD
VOL
W W/
WH
W/O
WP
XFMR
XFR
Ø C P L
L
ELECTRICAL ABBREVIATIONS LIST
SURFACE MOUNTED
SWITCH
SWITCHBOARD
SYMMETRICAL
SYSTEM
TIMECLOCK
TELEPHONE
TELEPHONE/DATA
TERMINAL
TWISTED PAIR
TWISTED PAIR SHIELDED
TAMPER RESISTANT
THERMOSTAT
TELEPHONE TERMINAL BOARD
TELEPHONE TERMINAL CABINET
TELEVISION
TYPICAL
UNDER COUNTER
UNDERGROUND ELECTRICAL
UNDERGROUND
UNIT HEATER
UNDERWRITER'S LABORATORY
UNDERGROUND TELEPHONE
UNSHIELDED TWISTED PAIR
UTILITY
UNIT VENTILATOR OR
ULTRAVIOLET
VOLT
VOLT-AMPERES
VERTICAL
VARIABLE FREQUENCY DRIVE
VOLUME
WATT
WITH
WATER HEATER
WITHOUT
WEATHERPROOF
TRANSFORMER
TRANSFER
ANGLE
AT
DELTA
FEET
INCHES
NUMBER
PHASE
CENTER LINE
PLATE
NOT APPLICABLE
NORMALLY CLOSED
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NON-FUSED SAFETY
DISCONNECT SWITCH
NOT IN CONTRACT
NIGHT LIGHT
NORMALLY OPEN
NATIONALLY RECOGNIZED TESTING
LABORATORY
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
OVERLOAD
PUBLIC ADDRESS
PULL BOX OR PUSHBUTTON
PREFABRICATED BEDSIDE
PATIENT UNIT
POLYCHLORINATED BYPHENYL
PHOTOELECTRIC CELL
PEDESTAL
PENDANT
POWER FACTOR
PHASE
POST INDICATING VALVE
PANEL
POWER-OVER-ETHERNET
PAIR
PRIMARY
PROJECTION
POWER ROOF VENTILATOR
POTENTIAL TRANSFORMER
POLYVINYL CHLORIDE (CONDUIT)
POWER
QUANTITY
REFLECTED CEILING PLAN
RECEPTACLE
REQUIRED
RIGID GALVANIZED STEEL
ROOM
ROOT MEAN SQUARE
ROOF TOP UNIT
SURFACE CONDUIT
SECONDARY
SQUARE FEET/FOOT
SHEET
INTERNATIONAL SYSTEM OF UNITS
SIMILAR
SOLID NEUTRAL
SPECIFICATION
SPEAKER
SPARE
SURFACE RACEWAY
STAINLESS STEEL
SELECTOR SWITCH
STANDARD
1 POLE (2P, 3P, 4P, ETC.)
1 PHASE
TWO-CONDUCTOR (3/C, 4/C, ETC.)
TWO-WIRE (3W, 4W, ETC.)
3 PHASE
AMPERE
ALARM ANNUNCIATOR PANEL
ABOVE COUNTER
AIR CONDITIONER
ALTERNATING CURRENT
ACCESSIBLE
ABOVE CEILING
AUTOMATIC DOOR OPENER
ARCHITECT/ENGINEER
AMP FRAME
AVAILABLE FAULT CURRENT
(KILOAMPS)
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ARC FAULT CIRCUIT
INTERRUPTER
AUTHORITY HAVING JURISDICTION
AIR HANDLING UNIT
AMPERE INTERRUPTING CAPACITY
ALUMINUM
ALTERNATE
AMPERE
APPROXIMATELY
ARCHITECT, ARCHITECTURAL
AMP TRIP
AUTOMATIC TRANSFER SWITCH
AUTOMATIC
AUXILIARY
AUDIO VISUAL
AMERICAN WIRE GAUGE
BUILDING AUTOMATION SYSTEM
BATTERY
BARE COPPER
BOARD
BELOW FINISHED FLOOR
BUILDING
BUILDING MANAGEMENT SYSTEM
BYPASS
CONDUIT
CABINET
CALCULATED
CAPACITY
CATALOG, CATEGORY
COMMUNITY ANTENNA TELEVISION
CIRCUIT BREAKER
CONTROL CONTACTOR
CLOSED CIRCUIT TELEVISION
CANDELA
CONSTRUCTION DOCUMENTS
CONTRACTOR-FURNISHED
CIRCUIT
CEILING
COAXIAL CABLE
COMMUNICATION
CONNECTION
CONSTRUCTION
CONTINUATION OR CONTINUOUS
CONTRACTOR
COORDINATE
CONTROL POWER TRANSFORMER
COLOR RENDERING INDEX
CURRENT TRANSFORMER
CABLE TELEVISION
CENTER
COPPER
CUBIC FEET
DECIBEL
DIRECT BURIAL
DIRECT CURRENT
DEGREES CELSIUS
DEGREES FAHRENHEIT
DEMOLISH/DEMOLITION
DEPARTMENT
DIAMETER
DISCONNECT
DISTRIBUTION
DOWN
SAFETY DISCONNECT SWITCH
DOUBLE THROW
DRAWING
ELECTRICAL CONTRACTOR
EQUIPMENT GROUND
ELECTRIC, ELECTRICAL
ELEVATOR
EMERGENCY
ELECTROMAGNETIC INTERFERENCE
ENERGY MANAGEMENT SYSTEM
ELECTRICAL METALLIC TUBING
EMERGENCY POWER OFF
EQUIPMENT
EASEMENT
ELECTRIC WATER COOLER
ELECTRIC WALL HEATER
ELECTRIC WATER HEATER
EXISTING
EXPLOSION PROOF
FIRE ALARM
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FOOTCANDLE
FAN COIL UNIT
FIXTURE
FLOOR
FLUORESCENT
FUSE
FUSED SAFETY DISCONNECT
SWITCH
FULL VOLTAGE REVERSING
FULL VOLTAGE NON-REVERSING
GALLON
GALVANIZED
GENERAL CONTRACTOR
GENERATOR
GROUND FAULT CIRCUIT
INTERRUPTER
GROUND
GALVANIZED RIGID STEEL
(CONDUIT)
GYPSUM BOARD
HIGH-INTENSITY DISCHARGE
HAND-OFF-AUTOMATIC
HORSEPOWER
HEIGHT
HEATER
HIGH VOLTAGE
HEATING, VENTILATING AND
AIR CONDITIONING
ILLUMINATION ENGINEERING SOCIETY
ISOLATED GROUND
INTERMEDIATE METAL CONDUIT
INFRARED
INTERLOCK WITH
INSTANTANEOUS WATER HEATER
JUNCTION BOX
KILOVOLT
KILOVOLT-AMPERE
KILOVOLT-AMPERE REACTIVE
KILOWATT
KILOWATT HOUR
LIGHT-EMITTING DIODE
LINEAR FEET/FOOT
LUMEN
LOCKED ROTOR AMPS
LIGHT
LIGHTING
LIGHTNING
LOW VOLTAGE
MASTER ANTENNA TELEVISION
SYSTEM
MAXIMUM
MECHANICAL CONTRACTOR
METAL-CLAD (CONDUIT)
MINIMUM CIRCUIT AMPACITY
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAIN DISTRIBUTION PANEL
MECHANICAL
MANUFACTURER
MAIN FUSED DISCONNECT
SWITCH
MANHOLE
MICROPHONE
MINIMUM
MISCELLANEOUS
MAIN LUGS ONLY
MULTIOUTLET ASSEMBLY
MAIN SWITCHBOARD
MOUNT
MANUAL TRANSFER SWITCH
MOTOR, MOTORIZED
GENERAL ELECTRICAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN ACCORDANCE
WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED PROCEDURES, ALL
APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND WITH THE LATEST EDITION
OF THE NATIONAL ELECTRICAL CODE.
PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE BUILDING
CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.
FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, UL LISTING REQUIREMENT AND THE APPLICABLE BUILDING CODES.
VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL REQUIRED MOUNTING
HARDWARE TO SUIT THE PARTICULAR INSTALLATION.
PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.
BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.
COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO AVOID
CONFLICT DURING CONSTRUCTION.
ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR SPARE, OR
SPACE.
MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER.
PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE ACCEPTED. ALL PRODUCTS MUST
COMPLY WITH "BUY AMERICAN ACT".
ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR
EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE
DEVICE'S SCREW TERMINALS.
MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT UNLESS
NOTED OTHERWISE.
ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.
ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.
ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. LFMC CONDUIT SHALL BE USED ON VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET). PVC SHALL BE USED FOR UNDERGROUND CONDUIT OR WHERE CONCRETE-ENCASED. WHERE VIBRATING EQUIPMENT IS LOCATED OUTSIDE, LFMC CONDUIT
SHALL BE USED (MAXIMUM SIX FEET) FOR FINAL CONNECTIONS.
ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN
APPROVED THIRD PARTY TESTING AGENCY (NRTL).
FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE
SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC
PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE
MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT
BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY.
PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.
IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS DETERMINED BY THE
GOVERNMENT, SHALL BE PROVIDED.
COMPRESSION COUPLINGS SHALL BE USED FOR EMT SIZED 3/4" TO 2".
ELECTRICAL CONTRACTOR SHALL FOLLOW SITE LOCK-OUT/TAG-OUT GUIDELINES TO DEENERGIZE
EQUIPMENT.
ELECTRICAL CONTRACTOR TO CONTACT SITE MANAGER FOR DISPOSAL OF REMOVED ELECTRICAL
EQUIPMENT.
ALL NEWLY INSTALLED PANELS SHALL BE LABLED ACCORDING TO NEC ARTICLE 110.
ELECTRICAL SYMBOL LEGEND
120V DUPLEX RECEPTACLE
RECEPTACLE MODIFIERS:
AC: 3" ABOVE COUNTERTOP/BACKSPLASH
GFI: GROUND FAULT CURRENT INTERRUPTER
WP: WEATHERPROOF ENCLOSURE
120V DUPLEX RECEPTACLE EMERGENCY OUTLET
AND COVER PLATE SHALL BE RED IN COLOR.
120V QUADRUPLEX RECEPTACLE
120V QUADRUPLEX RECEPTACLE EMERGENCY
JUNCTION BOX, PURPOSE AS NOTED
DISCONNECT SWITCH NON-FUSED
DISCONNECT SWITCH FUSED
SINGLE POLE MOTOR RATED SWITCH
SYMBOL HEIGHT DESCRIPTION
18"
18"
18"
18"
AS
NOTED
72" TOP
72" TOP
48"
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
TOP: HEIGHT TO TOP OF DEVICE
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
SPECIAL RECEPTACLE, WITH KEY NOTE
DESCRIPTION
EQUIPMENT CONNECTION
AS
NOTED
E
M
120V QUADRUPLEX FLOOR RECEPTACLEFLOOR
MOUNTED
GROUND BUS
PLUGMOLD
LIGHTING SYMBOL LEGEND
2' X 2' DIRECT/INDIRECT TROFFER
2' X 4' DIRECT/INDIRECT TROFFER
SYMBOL
HEIGHT
AFF * DESCRIPTION
WALL PACK - WALL MOUNTED
9'-0"
BOTTOM
6" DIAMETER RECESSED DOWNLIGHT---
EXIT SIGN - WALL MOUNTED
EXIT SIGN - CEILING MOUNTED---
7'-5"
BOTTOM
SINGLE POLE WALL SWITCH
WALL SWITCH DESIGNATORS:
OS: OCCUPANCY SENSOR, DUAL TECHNOLOGY
VS: VACANCY SENSOR, DUAL TECHNOLOGY
LV: LOW VOLTAGE
LVD: LOW VOLTAGE DIMMER
T: LINE VOLTAGE DIGITAL TIMER
3: 3 WAY
48"
CENTER
OS
OCCUPANCY SENSOR, DUAL
TECHNOLOGY - CEILING MOUNTED
LOW VOLTAGE LIGHTING CONTROL DEVICE -
MOUNTED ABOVE CEILING
OS OCCUPANCY SENSOR, DUAL TECHNOLOGY -
WALL, CORNER OR CEILING MOUNTED
2' LINEAR - WALL MOUNTED
7'-0"
CENTER
EMERGENCY LIGHT BATTERY OPERATED -
WALL MOUNTED
7'-6"
CENTER
RC
--- LOW VOLTAGE SINGLE RELAY LIGHTING CONTROL
DEVICE WITH 0-10V DIMMING - MOUNTED ABOVE CEILING
RCD
4' LINEAR - WALL MOUNTED
7'-0"
CENTER
* - ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
LS
LIGHT LEVEL SENSOR, SINGLE ZONE DIMMING
CLOSED LOOP - CEILING MOUNTED
--- LOW VOLTAGE DUAL RELAY LIGHTING CONTROL DEVICE
WITH 0-10V DIMMING - MOUNTED ABOVE CEILING
RCD2
--- LOW VOLTAGE THREE RELAY LIGHTING CONTROL
DEVICE WITH 0-10V DIMMING - MOUNTED ABOVE CEILING
RCD3
4' LINEAR STRIP
--- 2' LINEAR - SURFACE MOUNTED
1' LINEAR - SURFACE MOUNTED
--- 2' X 4' FLAT PRISMATIC LENS TROFFER
VS
VACANCY SENSOR, DUAL
TECHNOLOGY - CEILING MOUNTED
VS VACANCY SENSOR, DUAL TECHNOLOGY - WALL,
CORNER OR CEILING MOUNTED
FLOODLIGHT - WALL MOUNTED
9'-0"
BOTTOM
A1 b
E1 a
ELECTRICAL SYMBOL NOTES
THE LIGHTING FIXTURE TYPE IS INDICATED BY AN UPPER CASE LETTER
AND A NUMBER.
THE SWITCH DESIGNATION (IF NEEDED) IS INDICATED BY A LOWER CASE
LETTER.
EXAMPLE: LIGHTING FIXTURE TYPE 'A1' IS CONTROLLED BY SWITCH 'b'.
EXIT SIGN. STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING
MOUNTING.
SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES DIRECTIONAL
ARROW ON ILLUMINATED FACE(S).
EXAMPLE: LOW VOLTAGE DIMMER SWITCH 'a' TO CONTROL LIGHTING FIXTURES, LOCATED IN THE SAME SPACE, INDICATED BY 'a'.
SHEET KEY NOTE. SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE
NUMBER INDICATED IN THE HEXAGON.
HOME RUN TO BRANCH CIRCUIT PANEL. THE PANEL DESIGNATION AND
CIRCUIT DESIGNATION IS SHOWN ADJACENT TO THE HOME RUN ARROW.
CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE
PANEL SCHEDULE WITH THE CORRESPONDING PANEL AND CIRCUIT
DESIGNATION.
SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE A UNIT
TYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.
'LPN'-1,3,5
E2 EXAMPLE 1 : THE WALL MOUNTED EXIT SIGN TYPE 'E1' WITH SINGLE FACE AND
DIRECTIONAL ARROW.
EXAMPLE 2 : THE CEILING MOUNTED EXIT SIGN TYPE 'E2' WITH DOUBLE FACE AND
DIRECTIONAL ARROWS.
THE CONTROL DEVICE TYPE IS INDICATED BY UPPER CASE LETTERS.
THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.
LVD
EXAMPLE: HOME RUN TO PANEL 'LPN' CIRCUITS 1, 3, 5.
ALTERNATE A - REDUCE VESTIBULE AND OMIT COVERED RAMP:
WORK INCLUDES REDUCING THE ENTRY VESTIBULE TO 8' DEEP AND 10' WIDE.SLIDING
ENTRY DOORS AND HARDWARE WILL REMAIN. PROVIDE SIDEWALKAND STAIRS FROM
VESTIBULE TO EXISTING SIDEWALK AS WELL AS AN ADARAMP WITH CODE COMPLIANT
HANDRAILS AND GUARDRAILS.
ALTERNATE B - OMIT ELEVATOR:
WORK INCLUDES THE OMISSION OF ALL LABOR, MATERIAL, EQUIPMENT
ANDSUPERVISION TO PERFORM THE FURNISHING AND INSTALLATION OF
THEELEVATOR. THE ELEVATOR TOWER SHAFT SHALL NOT BE CONSTRUCTED,NEW
ADJACENT WALL CONSTRUCTION AND FLOOR SLAB SHALL CONTINUE TOTHE STAIR
AND THE INTERIOR SPACE ON THE BASEMENT AND FIRST FLOORSHALL BE
CONFERENCE ROOMS AND ALL WORK ASSOCIATED TO CREATE THECONFERENCE
ROOM SHALL BE PROVIDED WITHIN THIS ALTERNATE.
ALTERNATE C - OMIT SLIDING EXAM/PATIENT ROOM DOORS:
WORK INCLUDES THE OMISSION OF ALL LABOR, MATERIAL, EQUIPMENT,
ANDSUPERVISION TO PROVIDE SLIDING DOORS AT THE PATIENT AND STAFF
ENTRYINTO EXAM ROOMS. TYPICAL 42" WOOD SWING DOORS AND
HARDWAREOUTLINED IN THE HARDWARE SCHEDULE SHALL BE PROVIDED WITHIN
THISALTERNATE.
ALTERNATE D - REDUCE CRAWLSPACE:
WORK INCLUDES THE OMISSION OF ALL LABOR, MATERIAL, EQUIPMENT,
ANDSUPERVISION TO PROVIDE A 7' HEAD HEIGHT IN THE CRAWLSPACE ANDCONCRETE
SLAB FLOOR. THE CRAWLSPACE SHALL BE CONSTRUCTED WITH A 4' HEAD HEIGHT
FROM 82' T/SLAB TO 85' T/SLAB DEPTH WITH A TYPICALDIRT/EARTH FLOOR.
ALTERNATE E - OMIT CANOPY EXTENSION (EXISTING BUILDING):
WORK INCLUDES THE OMISSION OF ALL LABOR, MATERIAL, EQUIPMENT,
ANDSUPERVISION TO PROVIDE CANOPY EXTENSION AT LOADING DOCK.
ALTERNATE F - OMIT REMODEL WORK ON FIRST FLOOR:
WORK INCLUDES THE OMISSION OF ALL LABOR, MATERIALS, EQUIPMENT
ANDSUPERVISION TO ALL RENOVATION WORK IN EXISTING BUILDING 154A ON THEFIRST
FLOOR. ROOM A187, EYE RESOURCE SHALL BE CONVERTED INTO ACORRIDOR.
REMOVE DOOR TO THIS ROOM FOR EGRESS. WORK SHALLREMAIN TO ADDITION OF
STORAGE ROOM A164 TO MAINTAIN FIRE EXISTS. ALL OTHER ROOMS ON FIRST FLOOR
SHALL BE EXISTING TO REMAIN.
ALTERNATE G - OMIT SECURITY GATE:
STATEMENT OF BID ITEMS
A
B
C
D
E
F
G
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\j m e ie r\ D o c u m e n ts
\1 -1
E le c tr ic a l M o d e l_ jm e ie r@ a c g -p a .c o m
.r v t
/1
/2
:1
:4
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
ELECTRICAL NOTES, LEGENDS,
AND ABBREVIATIONS
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
E-001Revisions: Date: 7/13/2018
DocuSign Envelope ID: 27783D38-E586-400F-8518-71AFB6E851C0
UNSURE OF WATER AND
SANITARY LINES IN
THIS LOCATION
UNSURE OF WATERLINE IN
THIS LOCATION
A
S A D
IE
P H A R M
N E W
A D D
IT
IO
N
R tp02DRILLHOLE
15282 3981.74
MH11
MH12
MH13
MH10
# SHEET KEY NOTES:
SHEET NOTES:
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\j m e ie r\ D o c u m e n ts
\1 -1
E le c tr ic a l M o d e l_ jm e ie r@ a c g -p a .c o m
.r v t
/1
/2
:1
:1
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
ELECTRICAL SITE PLAN
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
ES101
SCALE: 1" = 30'-0"ES101
1 ELECTRICAL SITE PLAN
A.
B.
C.
D.
E.
ELECTRICAL CONTRACTOR TO REFERENCE
EXISTING SITE DRAWINGS E1.0 AND E3.0 ON
PAGES E-900 AND E-901 FOR LOCATION AND
DISTANCE.
ELECTRICAL CONTRACTOR SHALL FOLLOW
SITE LOCK-OUT/TAG-OUT GUIDELINES TO
DEENERGIZE EQUIPMENT.
REFERENCE SHEET CU101 FOR MORE
INFORMATION.
ALL NEW UNDERGROUND CONDUITS
INDICATED SHOULD BE BORED IF POSSIBLE.
COORDINATE WITH SITE UTILITIES IN ORDER
TO AVOID DAMAGE TO UNDERGROUND
COMMUNICATIONS LINES.
1 NEW UNDERGROUND SERVICE LATERAL
FROM NEW TRANSFORMER TO NEW BUILDING
ADDITION. ROUTE UNDERGROUND FROM
TRANSFORMER JUNCTION BOX AND
PENETRATE INTO CRAWLSPACE. ROUTE
THROUGH CRAWLSPACE. REFERENCE SHEET
EP104 FOR FURTHER ROUTING INFORMATION.
REFERENCE SHEET E-501 DETAIL 10 FOR
DUCT BANK DETAIL.
2 EXISTING TRANSFORMER TF 150 TO REMAIN.
3 NEW 300 KVA SERVICE TRANSFORMER TF 172
FOR NEW ADDITION. NEW TRANSFORMER PAD
AND VAULT TO BE INSTALLED. INCLUDE 2'
WALKAROUND FOR TRANSFORMER, AND
CONTAINMENT PIT FOR TRANSFORMER OIL.
BOLLARDS TO BE PLACED AROUND NEW
TRANSFORMER PAD. REFERENCE CIVIL
SHEET CS501 FOR BOLLARD DETAIL.
REFERENCE ELECTRICAL SHEET E-501 DETAIL
3 FOR TRANSFORMER PAD DETAIL.
4 EXISTING UNDERGROUND MV FEEDER TO TF
150 TO REMAIN.
5 NEW UNDERGROUND MV DUCTBANK FROM
MH-12 TO FEED NEW TRANSFORMER.
REFERENCE SHEET E-501 DETAIL 10.
6 EXISTING MV SWITCH 12 TO REMAIN.
7 EXISTING SECTIONALIZER SE-12.
8 IN EXISTING SECTIONALIZER ENCLOSURE,
REPLACE EXISTING 200A 3-POINT LOAD
BREAK JUNCTIONS WITH NEW 200A 4-POINT
LOAD BREAK JUNCTIONS. CORE DRILL WALL
OF EXISTING MH 12 AS REQUIRED FOR NEW
UNDERGROUND DUCT ENTRIES. TERMINATE
NEW MV FEEDER TO NEW FOUR-POINT LOAD
BREAK JUNCTIONS.
9 EXISTING 15 KV UNDERGROUND LINE TO BE
REROUTED VIA NEW MANHOLE AROUND NEW
ADDITION. INTERCEPT EXISTING CONDUIT
AND REROUTE AROUND BUILDING FOOTING
AND EXTEND INTO NEW MANHOLE.
COORDINATE ROUTING WITH SITE UTILITY.
REFERENCE DETAILS 9 AND 10 ON SHEET
E-501.
10 NEW LOW-VOLTAGE SWITCHGEAR PDB1
LOCATED IN ELECTRICAL ROOM B109. ROUTE
ALL CONDUIT UNDERGROUND AND THROUGH
CRAWLSPACE. REFERENCE SHEETS EP101,
EP104, AND E-401. REFERENCE SHEET E-501
DETAIL 11.
11 EXISTING UNDERGROUND FIBER OPTIC
CABLE.
12 EXISTING UNDERGROUND CONDUIT
13 LOCATION OF NEW MANHOLE WITH OPENING
FOR RELOCATED EXISTING MV
SECTIONALIZER. REFERENCE SHEET E-503
DETAIL 6 FOR POWER MANHOLE DETAILS.
GROUND AS INDICATED ON SHEET E-503
DETAIL 7.
14 EXISTING UNDERGROUND 4" CONDUIT.
15 EXTEND EXISTING 4" CONDUIT INTO NEW
MANHOLE.
16 EXISTING SECTIONALIZER SE-11 INSTALLED
OVER MH11.
17 REFERENCE CIVIL SITE PLAN SHEET CD101
REGARDING REMOVAL OF TREE.
18 NEW GATE FED FROM PANEL '172-B2'.
CONTRACTOR TO INSTALL 2-10 AWG AND 1-10
AWG EG IN 1" CONDUIT. COORDINATE
PLACEMENT WITH GATE MANUFACTURER AND
INSTALLER.
19 CONTRACTOR TO ENSURE INTEGRITY OF
EXISTING UNDERGROUND
TELECOMMUNICATIONS LINES IN THIS AREA.
COORDINATE WITH OTHER TRADES.
20 BID ALTERNATE 'G', SEE GI103 FOR MORE
INFORMATION. DO NOT PROVIDE POWER OR
RUN CONDUIT FOR SECURITY GATE.
G. ELECTRICAL CONTRACTOR TO TERMINATE NEW MV CABLES.
F. ELECTRICAL CONTRACTOR TO TEST NEW MV CABLES,
E. ELECTRICAL CONTRACTOR TO INSTALL NEW MV CABLES BETWEEN MH #14/MSW #14(14.1A) AND
MH#11/SE #11(13B) AND BETWEEN MH# 14/SE #14(14A) AND MH #12/MSW #12(12B), (1 SET OF 3#1/0
15KV TYPE MV-105 XLPE CU PHASE CONDUCTORS WITH 1-#2 CU AWG 600V INSULATED GROUND
CONDUCTOR PER INSTALLATION)
D. ELECTRICAL CONTRACTOR TO INSTALL NEW UNDERGROUND CONDUITS BETWEEN MH #13 AND MH #10, (4-5” PVC WITH CONCRETE COVERING)
C. ELECTRICAL CONTRACTOR TO DEMO THE EXISTING CONDUITS BETWEEN MANHOLES #13 AND #10
B. ELECTRICAL CONTRACTOR TO REMOVE EXISTING MV CABLES BETWEEN MH #14/MSW #14 AND
MH#11/SE #11 AND REMOVE EXISTING MV CABLES BETWEEN MH# 14/SE #14 AND MH #12/MSW #12
A. ELECTRICAL CONTRACTOR TO DISCONNECT THE EXISTING MV CABLES AT MH #14/MSW #14(14.1A) AND
AT MH#11/SE #11(13B) AND AT MH# 14/SE #14(14A) AND AT MH #12/MSW #12(12B)
ELECTRICAL CONTRACTOR SITE INSTRUCTIONS:
Revisions: Date: 7/13/2018
REF.
FF
S
I J K L M N O P Q R
S
EX
ACCU
EX
ACCU
EX
LOUVER
172-RH-13
# SHEET KEY NOTES:
SHEET NOTES:
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\j m e ie r\ D o c u m e n ts
\1 -1
E le c tr ic a l M o d e l_ jm e ie r@ a c g -p a .c o m
.r v t
/1
/2
:1
:2
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
BASEMENT ELECTRICAL
DEMOLITION PLAN
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
ED101
N
SCALE: 1/8" = 1'-0"ED101
1 BASEMENT ELECTRICAL DEMOLITION PLAN
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
CONTRACTOR SHALL BE RESPONSIBLE FOR
TRACING AND IDENTIFYING ALL CIRCUITS AND
CONDUITS THAT ORIGINATE, PASS THROUGH,
OR TERMINATE IN THE AREA OF WORK.
DEMOLISH ALL CIRCUITS THAT ARE NO
LONGER IN USE. MAINTAIN CIRCUIT
CONTINUITY TO ALL CIRCUITS WHICH ARE NOT
COMPLETELY REMOVED.
CONTRACTOR TO DISCONNECT AND REMOVE
ELECTRICAL CONNECTION TO OUTLETS,
RECEPTACLES, HVAC EQUIPMENT AND OTHER
ELECTRICAL DEVICES. REMOVE CONDUCTORS
AND CONDUIT BACK TO PANELBOARD
SERVING EQUIPMENT OR TO THE POINT
WHERE OTHER REMAINING LOADS ARE
CONNECTED. MARK EXISTING OVERCURRENT
PROTECTION DEVICE AS "SPARE (UNUSED)".
CONTRACTOR SHALL REMOVE ALL
ELECTRICAL CONDUIT, CABLE, WIRING,
DEVICE, JUNCTION BOXES, FITTINGS, AND
RELATED ITEM FROM ALL PORTIONS OF THE
AREA OF WORK INCLUDING WALL, CEILING
AND FLOORS. THIS SHALL BE FOR ALL WALLS,
EVEN WALLS NOT SUBJECT TO REMOVAL.
FOR ELECTRICAL CIRCUITS BEING
DEMOLISHED REMOVE BOXES, CONDUIT AND
CONDUCTORS BACK TO SOURCE, INCLUDING
THOSE CONCEALED WITHIN WALLS, LEAVING
NO ABANDONED ITEMS.
WHERE CONDUIT IS REMOVED FROM AN
EXISTING RATED ASSEMBLY NOT SUBJECT TO
DEMOLITION, THE REMAINING HOLE SHALL BE
PATCHED/REPAIRED TO MAINTAIN THE RATING
OF THE ASSEMBLY.
EACH PHASE OF THE CONSTRUCTION IS TO BE
PERFORMED WHILE LEAVING WORK AREAS OF
OTHER PHASES ACTIVE, TO THE GREATEST
EXTENT POSSIBLE. NOTIFY COR IF ANY WORK
IS REQUIRED THAT WILL CROSS MULTIPLE
PHASES OF THE WORK AREA, PRIOR TO
PERFORMING THE WORK.
ELECTRICAL CONTRACTOR SHALL FOLLOW
SITE LOCK-OUT/TAG-OUT GUIDELINES TO
DEENERGIZE EQUIPMENT.
ELECTRICAL CONTRACTOR TO CONTACT SITE
MANAGER FOR DISPOSAL OF REMOVED
ELECTRICAL EQUIPMENT.
DEVICES INDICATED WITH HIDDEN LINES ARE
TO BE REMOVED, UNLESS NOTED OTHERWISE.
COOLING UNITS FED OUT OF BUILDING 150
ROOM B9.
1 EXISTING AIR HANDLER UNIT 'ACCU 1' FED
FROM PANEL 'MDP' CIRCUIT 7. AIR HANDLER
UNIT IS TO BE RELOCATED, AND ALL FEEDERS
REMOVED BACK TO PANEL. AIR HANDLER
UNIT WILL BE REFED FROM NEW PANEL.
REFERENCE SHEET EP103. SALVAGE
DISCONNECT AND RETURN TO VA.
2 EXISTING AIR HANDLER UNIT 'ACCU 2' FED
FROM 300A CIRCUIT BREAKER ON PANEL
'154A-BF1' CIRCUIT 9. AIR HANDLER UNIT IS TO
BE RELOCATED, AND ALL FEEDERS REMOVED
BACK TO PANEL. ELECTRICAL CONTRACTOR
TO INSTALL NEW FEEDERS AND CONDUIT
FROM PANEL '154A-BF1' TO NEW LOCATION.
REFERENCE SHEET EP103. SALVAGE
DISCONNECT AND RETURN TO VA.
3 EXISTING FAN AND MOTOR. FAN AND
ASSOCIATED EQUIPMENT TO BE REMOVED,
AND CIRCUIT FEEDING MOTOR TO BE
REMOVED BACK TO PANEL. CONTRACTOR TO
COORDINATE WITH SITE MAINTENANCE AND
COR TO LOCATE FEEDING PANEL AND
CIRCUIT.
4 DOOR TO BE SALVAGED. RETURN ALL
ASSOCIATED HARDWARE TO VA.
GFI
GFI
B C D E F G
H I J K L M N O P Q R
S T
EX
EX
EX
EX EX
EX
EXEX
EX
EX
EX EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EXEX
EX
EX
EXEX
EX
EX
EX
EX
EX
EX
EX
EXEX
EX
EX
INDICATED ELECTRICAL DEVICES IN THIS
BORDERED AREA FED FROM EXISTING
PANEL '154A-1F1' CIRCUITS 1,3. CONTRACTOR
TO LOCATE PANEL AND VERIFY FOR LOCK-
OUT/TAG-OUT PURPOSES PRIOR TO WORK.
INDICATED ELECTRICAL DEVICES IN THIS
AREA FED FROM EXISTING PANEL 'D'.
CONTRACTOR TO LOCATE PANEL AND
VERIFY FOR LOCK-OUT/TAG-OUT
PURPOSES PRIOR TO WORK.
# SHEET KEY NOTES:
SHEET NOTES:
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\j m e ie r\ D o c u m e n ts
\1 -1
E le c tr ic a l M o d e l_ jm e ie r@ a c g -p a .c o m
.r v t
/1
/2
:1
:3
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
FIRST FLOOR ELECTRICAL
DEMOLITION PLAN
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
ED102
N
SCALE: 1/8" = 1'-0"ED102
1 FIRST FLOOR ELECTRICAL DEMOLITION PLAN
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
CONTRACTOR SHALL BE RESPONSIBLE FOR
TRACING AND IDENTIFYING ALL CIRCUITS AND
CONDUITS THAT ORIGINATE, PASS THROUGH,
OR TERMINATE IN THE AREA OF WORK.
DEMOLISH ALL CIRCUITS THAT ARE NO
LONGER IN USE. MAINTAIN CIRCUIT CONTINUITY
TO ALL CIRCUITS WHICH ARE NOT
COMPLETELY REMOVED.
CONTRACTOR TO DISCONNECT AND REMOVE
ELECTRICAL CONNECTION TO OUTLETS,
RECEPTACLES, HVAC EQUIPMENT AND OTHER
ELECTRICAL DEVICES. REMOVE CONDUCTORS
AND CONDUIT BACK TO PANELBOARD SERVING
EQUIPMENT OR TO THE POINT WHERE OTHER
REMAINING LOADS ARE CONNECTED. MARK
EXISTING OVERCURRENT PROTECTION DEVICE
AS "SPARE (UNUSED)".
CONTRACTOR SHALL REMOVE ALL
ELECTRICAL CONDUIT, CABLE, WIRING,
DEVICE, JUNCTION BOXES, FITTINGS, AND
RELATED ITEM FROM ALL PORTIONS OF THE
AREA OF WORK INCLUDING WALL, CEILING AND
FLOORS. THIS SHALL BE FOR ALL WALLS, EVEN
WALLS NOT SUBJECT TO REMOVAL.
FOR ELECTRICAL CIRCUITS BEING
DEMOLISHED REMOVE BOXES, CONDUIT AND
CONDUCTORS BACK TO SOURCE, INCLUDING
THOSE CONCEALED WITHIN WALLS, LEAVING
NO ABANDONED ITEMS.
WHERE CONDUIT IS REMOVED FROM AN
EXISTING RATED ASSEMBLY NOT SUBJECT TO
DEMOLITION, THE REMAINING HOLE SHALL BE
PATCHED/REPAIRED TO MAINTAIN THE RATING
OF THE ASSEMBLY.
EACH PHASE OF THE CONSTRUCTION IS TO BE
PERFORMED WHILE LEAVING WORK AREAS OF
OTHER PHASES ACTIVE, TO THE GREATEST
EXTENT POSSIBLE. NOTIFY COR IF ANY WORK
IS REQUIRED THAT WILL CROSS MULTIPLE
PHASES OF THE WORK AREA, PRIOR TO
PERFORMING THE WORK.
ELECTRICAL CONTRACTOR SHALL FOLLOW
SITE LOCK-OUT/TAG-OUT GUIDELINES TO
DEENERGIZE EQUIPMENT.
ELECTRICAL CONTRACTOR TO CONTACT SITE
MANAGER FOR DISPOSAL OF REMOVED
ELECTRICAL EQUIPMENT.
DEVICES INDICATED WITH HIDDEN LINES ARE
TO BE REMOVED, UNLESS NOTED OTHERWISE.
DEMOED LED LIGHTING FIXTURES TO BE
RETURNED TO VA FOR REINSTALLATION.
REFERENCE SHEETS EP104, EL101, EL102, AND
EL103.
1 BID ALTERNATE 'F', SEE GI103 FOR MORE
INFORMATION. NO REMODEL WORK TO TAKE
PLACE IN EXISTING BUILDING IN FIRST FLOOR.
D
D
D
D
D
B C D E F G
H I J K L M N O P Q R
S
EX
EX
EX
EX EX
EXEX
EX
EXEX
EX EX
EX
EX
EXEX
EXEX
EX
EXEX
EX
EXEX
EX
EX
EX
EXEX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX EX
EX EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
INDICATED ELECTRICAL DEVICES IN THIS
BORDERED AREA FED FROM EXISTING
PANEL '154A-1F1' CIRCUITS 1,3. CONTRACTOR
TO LOCATE PANEL AND VERIFY FOR LOCK-
OUT/TAG-OUT PURPOSES PRIOR TO WORK.
INDICATED ELECTRICAL DEVICES IN THIS
AREA FED FROM EXISTING PANEL 'D'.
CONTRACTOR TO LOCATE PANEL AND
VERIFY FOR LOCK-OUT/TAG-OUT
PURPOSES PRIOR TO WORK.
# SHEET KEY NOTES:
SHEET NOTES:
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\j m e ie r\ D o c u m e n ts
\1 -1
E le c tr ic a l M o d e l_ jm e ie r@ a c g -p a .c o m
.r v t
/1
/2
:1
:3
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
FIRST FLOOR LIGHTING
DEMOLITION PLAN
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
ED103
N
SCALE: 1/8" = 1'-0"ED103
1 FIRST FLOOR LIGHTING DEMOLITION PLAN
1 EXISTING LIGHT FIXTURE TO BE DEMOLISHED
AND RETURNED TO VA.
2 EXISTING DOWNLIGHT TO BE REMOVED
(TYPICAL).
3 CORRIDOR CEILING IN THIS AREA TO BE TAKEN
DOWN DURING CONSTRUCTION AND
REINSTALLED. REFERENCE ARCHITECTURAL
REFLECTED CEILING PLANS.
4 BID ALTERNATE 'F', SEE GI103 FOR MORE
INFORMATION. NO REMODEL WORK TO TAKE
PLACE IN EXISTING BUILDING IN FIRST FLOOR.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
CONTRACTOR SHALL BE RESPONSIBLE FOR
TRACING AND IDENTIFYING ALL CIRCUITS AND
CONDUITS THAT ORIGINATE, PASS THROUGH,
OR TERMINATE IN THE AREA OF WORK.
DEMOLISH ALL CIRCUITS THAT ARE NO LONGER
IN USE. MAINTAIN CIRCUIT CONTINUITY TO ALL
CIRCUITS WHICH ARE NOT COMPLETELY
REMOVED.
CONTRACTOR TO DISCONNECT AND REMOVE
ELECTRICAL CONNECTION TO OUTLETS,
RECEPTACLES, HVAC EQUIPMENT AND OTHER
ELECTRICAL DEVICES. REMOVE CONDUCTORS
AND CONDUIT BACK TO PANELBOARD SERVING
EQUIPMENT OR TO THE POINT WHERE OTHER
REMAINING LOADS ARE CONNECTED. MARK
EXISTING OVERCURRENT PROTECTION DEVICE
AS "SPARE (UNUSED)".
CONTRACTOR SHALL REMOVE ALL ELECTRICAL
CONDUIT, CABLE, WIRING, DEVICE, JUNCTION
BOXES, FITTINGS, AND RELATED ITEM FROM ALL
PORTIONS OF THE AREA OF WORK INCLUDING
WALL, CEILING AND FLOORS. THIS SHALL BE
FOR ALL WALLS, EVEN WALLS NOT SUBJECT TO
REMOVAL.
FOR ELECTRICAL CIRCUITS BEING DEMOLISHED
REMOVE BOXES, CONDUIT AND CONDUCTORS
BACK TO SOURCE, INCLUDING THOSE
CONCEALED WITHIN WALLS, LEAVING NO
ABANDONED ITEMS.
WHERE CONDUIT IS REMOVED FROM AN
EXISTING RATED ASSEMBLY NOT SUBJECT TO
DEMOLITION, THE REMAINING HOLE SHALL BE
PATCHED/REPAIRED TO MAINTAIN THE RATING
OF THE ASSEMBLY.
EACH PHASE OF THE CONSTRUCTION IS TO BE
PERFORMED WHILE LEAVING WORK AREAS OF
OTHER PHASES ACTIVE, TO THE GREATEST
EXTENT POSSIBLE. NOTIFY COR IF ANY WORK IS
REQUIRED THAT WILL CROSS MULTIPLE PHASES
OF THE WORK AREA, PRIOR TO PERFORMING
THE WORK.
ELECTRICAL CONTRACTOR SHALL FOLLOW SITE
LOCK-OUT/TAG-OUT GUIDELINES TO
DEENERGIZE EQUIPMENT.
ELECTRICAL CONTRACTOR TO CONTACT SITE
MANAGER FOR DISPOSAL OF REMOVED
ELECTRICAL EQUIPMENT.
DEVICES INDICATED WITH HIDDEN LINES ARE TO
BE REMOVED, UNLESS NOTED OTHERWISE.
DEMOED LED LIGHTING FIXTURES AND EXIT
LIGHTS TO BE RETURNED TO VA FOR
REINSTALLATION. REFERENCE SHEETS EP104,
EL101, EL102, AND EL103. COORDINATE WITH
COR. COORDINATE STORAGE OF DEMOED
LIGHTING FIXTURES WITH COR.
DEMOLISHED CIRCUITS FED FROM PANEL
'154A-1F1' CIRCUITS 1 & 3, AND PANEL 'D'.
CONTRACTOR TO CONFIRM AND LOCK OUT
AFFECTED CIRCUIT, AND MARK AS SPARE IF
APPROPRIATE.
UP
DN
AC
GFI
AC
GFI AC
GFI
GFI
GFI
DED
AC
GFI
GFI
DED
GFI
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
GFI GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
16"
GFI
DED
AC
GFI
GFI
WP
2 2
2 2
2 2
2 2
GFI
GFI
J
J
72" 72"
AC
GFI
GFI
JJJ
J
JJJJJJ
J
AC
AC
J
J
J
J
J J J
J
J
JJJJJJ
J
J J
J J
GFI
WP
GFI
WP
GFI
WP
60"60"
GFI
J
60"
60"
GFI
WP
2 2
M
J
CLNG
CLNG
J GFI
WP
60"
J
J
AC
GFI
J
K L M N O P Q R
ELEV 1
B103
STAIR 1
B102
COFFEE
B100C
B-9
VEST
C-3
STORAGE
B31J
WORK ROOM
B31I
OFFICE
B31G
Unoccupied
Unoccupied OFFICE
B31D
SPEECH
B31E
POOL THERAPY
B31P
TELEMEDICINE
B31H
WAITING
B31B
RECEPT
B31C
HALLWAY
B31F
MECHANICAL
B2
OFFICE
B1
REHABILITATION
SERVICES
B31A
IRM
B30
MECHANICAL
ROOM
B32
ELEV
Unoccupied
Unoccupied
B-13 B-11
Unoccupied
Unoccupied
EXAM/CONSULT 5
B129
EXAM/CONSULT 6
B128
EXAM/CONSULT 7
B127
EXAM/CONSULT 8
B126
P. TOILET
BARIATRIC
B136B
STAFF TOILET
B120
RECEPTION
B101
H.W. ALCOVE
B143
BARIATRIC TOILET
B104
FAMILY TOILET
B105
P. TOILET
B132
EXAM/CONSULT 3
B131
PROCEDURE
ROOM
B136
EXAM/CONSULT 2
B133
EXAM/CONSULT 1
B134
WOMEN'S EXAM
B135
CORRIDOR
B115Unoccupied
Unoccupied
UNISEX TOILET
B106
OT
B31K
EXAM
B31L
EXAM
B31M
EXAM
B31N
PT WORK AREA
B310
Unoccupied
Unoccupied
EXAM/CONSULT 4
B130
ELEC.
B111
EQUIP. STOR.
B122
TELE HEALTH
B146
HSK
B112
P. TOILET
B145
DATA
B113
WORK ROOM /
PATIENT
COUNSELLING
B117
CONFERENCE/
BREAK
B114
CLEAN SUPPLY
B123
MED ROOM
B124 EXAM/CONSULT 9
B125
CORRIDOR
B144
COPIER/FAX
B140
TEAM WORK AREA
B139
FIRE SPRINKLER
B137
CORRIDOR
B138
CRAWL SPACE
C101
COMPRESSORS
B-12
S T U V W
E-401
E-401
E-401
'172-B3'- 41
'172-B3'- 37
'172-B3'- 44
'172-B3'- 29
'172-B3'- 38 '172-B3'- 36
'172-B3'- 40
'172-B3'- 20
'172-B3'- 21 '172-B3'- 17
'172-B3'- 13
'172-B3'- 9 '172-B3'- 5
'172-B2'- 37
'172-B3'- 6 '172-B3'- 16
'172-B3'- 18
'172-B3'- 48
'172-B3'- 26 '172-B3'- 33
'172-B3'- 24
'172-B3'- 25
'172-B3'- 34
'172-B3'- 22
'172-B3'- 46
'172-B2'- 22
PANEL
'172-B2'
PANEL
'172-B3'
'172-B2'- 24
'172-B3'- 2
'172-B3'- 4
'172-B3'- 10 '172-B3'- 12
'172-B3'- 32
'172-B3'- 30
SHARED MED
STORAGE
B110
'172-B2'- 39
'172-B2'- 43
WAITING
B100
'172-B3'- 27
E-401
'172-B3'- 8
'172-B3'- 35
22'172-B3'- 39
'172-B3'- 43
'172-B3'- 23
'172-B3'- 31
'172-B3'- 19
'172-B3'- 15
'172-B3'- 11
'172-B3'- 7
'172-B3'- 3
'172-B2'- 29
'172-B2'- 31
'172-B2'- 33
'172-B2'- 34,36
'172-B3'- 42
'172-B2'- 20
'172-B3'- 45
'172-B3'- 1
'172-B3'- 28
'172-B2'- 28
SOILED HOLDING
B121
'172-B2'- 10
'172-B3'- 14 7
STAFF TOILET
B119
'172-B3'- 49
'172-B3'- 47
'172-B3'- 51
'172-B3'- 50
'172-B2'- 25
'172-B2'- 27
'172-B2'- 35
'172-B2'- 6
'172-B2'- 9
'172-B2'- 18
'172-B3'- 54
'172-B2'- 23
'172-B2'- 17
'172-B2'- 19
'172-B2'- 21
'172-B2'- 49
'172-B2'- 51
'172-B2'- 53
'172-B2'- 55
'172-B2'- 57
SHARED OFFICE
B107
SHARED OFFICE
B108
TELE HEALTH
B109
'172-B4IT'- 9
'172-B3'- 60
'172-B3'- 58
'172-B3'- 56
'172-B2'- 41
154 A
SADIE
PHARMACY
MED LAB
PROJECT
AREA
N N
KEYPLANPLAN NORTHTRUE NORTH
# SHEET KEY NOTES:
SHEET NOTES:
WALL RATING LEGEND
1 HR FIRE SEPARATION
2 HR FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\j m e ie r\ D o c u m e n ts
\1 -1
E le c tr ic a l M o d e l_ jm e ie r@ a c g -p a .c o m
.r v t
/1
/2
:1
:0
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
BASEMENT POWER PLAN
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
EP101
N
SCALE: 1/8" = 1'-0"EP101
1 BASEMENT POWER PLAN
A.
B.
C.
D.
E.
F.
SEE E-401 FOR ELECTRICAL ROOM AND
CLOSET ENLARGEMENTS.
ALL RECEPTACLE CONDUCTORS ARE 2-12
AWG, 1-12 AWG EG IN 3/4" CONDUIT MINIMUM
UNLESS NOTED OTHERWISE.
COORDINATE LOCATION AND ELECTRICAL
REQUIREMENTS OF ALL MECHANICAL AND
PLUMBING EQUIPMENT WITH MECHANICAL
AND PLUMBING CONTRACTORS.
COORDINATE EQUIPMENT WITH
ARCHITECTURAL EQUIPMENT PLANS AND
SCHEDULES.
ELECTRICAL CONTRACTOR SHALL FOLLOW
SITE LOCK-OUT/TAG-OUT GUIDELINES TO
DEENERGIZE EQUIPMENT.
ALL RECEPTACLES SHALL HAVE THEIR
SOURCE PANEL AND CIRCUIT NUMBER
INDICATED ON THEIR FACEPLATE.
1 JUNCTION BOX TO POWER CEILING-MOUNTED
OVERHEAD LIFT
2 POKE-THRU TO POWER EXAM TABLE.
CONNECT TO JUNCTION BOX IN
CRAWLSPACE.
3 CEILING-MOUNTED JUNCTION BOX TO POWER
ENTRANCEWAY AUTOMATIC DOOR OPENER.
CONTRACTOR TO PROVIDE FIXTURE WHIP TO
DEVICE IF NECESSARY. COORDINATE EXACT
LOCATION WITH VA AND DEVICE
MANUFACTURER.
4 TRANSFORMER PAD LOCATION WITH 2'
WALKABOUT. REFERENCE SHEET ES101 AND
E-501 DETAIL 3.
5 PROVIDE JUNCTION BOX TO POWER
LOW-VOLTAGE TRANSFORMER MOUNTED IN
WALL WITH PANEL ACCESS FOR AUTOMATIC
PLUMBING FIXTURES. COORDINATE WITH
PLUMBING CONTRACTOR.
6 PROVIDE JUNCTION BOX TO POWER
LOW-VOLTAGE TRANSFORMER FOR
AUTOMATIC PLUMBING FIXTURES.
COORDINATE WITH PLUMBING CONTRACTOR.
7 CEILING-MOUNTED JUNCTION BOX TO POWER
ENTRANCEWAY SIGN. CONTRACTOR TO
PROVIDE FIXTURE WHIP TO DEVICE IF
NECESSARY. COORDINATE EXACT LOCATION
WITH VA AND DEVICE MANUFACTURER.
8 RECEPTACLES TO POWER OMNICELL
EQUIPMENT. COORDINATE FINAL PLACEMENT
OF RECEPTACLES WITH MANUFACTURER.
9 JUNCTION BOX TO POWER CEILING-MOUNTED
OVERHEAD PROJECTOR SCREEN.
COORDINATE WITH DEVICE MANUFACTURER.
10 JUNCTION BOX TO BE FACE MOUNTED TO
CENTER BEAM FOR INSTALLATION OF FUTURE
FAN. PROVIDE ASSOCIATED CONDUIT AND
FITTINGS TO PANEL '172-B2', AND INCLUDE
PULL STRINGS IN CONDUIT.
11 CONTRACTOR TO INSTALL 3 -3/4" SPARE
CONDUITS FROM ROOM B-111 TO VESTIBULE
AND J-BOXES IN CONCRETE LANDING EAST
FACE RAMP WALL NORTH OF STAIRS.
COORDINATE LOCATION WITH COR.
12 BID ALTERNATE 'A', SEE GI103 FOR MORE
INFORMATION. REDUCE LIGHTING AND
RECEPTACLES PROVIDED IN VESTIBULE
AREA.
AC
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
16"
GFI
DED
GFI
GFIGFI
GFI GFI
AC
GFI
AC
GFI
GFI
DED
GFI
60"
AC
GFI
GFI
AC
GFI
AC
GFI
AC
GFI
G
FI
A C
G
FI
GFI
GFI
GFI
2 2
22 2
60"
GFI
GFI
72"72"
J
J
J
J J J
JJJJJ
J
J
AC
AC
J
J
J
J J
J
J J J J J J
JJJJJ
J
J
GFI
AC
GFI
GFI
J J
J
60"
60"
G
FI
4 4
CLNG
CLNG
J
GFI
60"
J
J
CLNG
J
60" 4 4 4
I J K L M N O P Q R
ENT OFFICE
A169
A176 SPECIALIST
A176
EXAM
EYE EXAM C3
A184
STOR
A166A
TOILET
A166
PROCEDURE
A168
FEMALE TOILET
A171
MALE TOILET
A172
TELEHEALTH
A188
TOILET
A202
BARIATRIC TOILET
A104
OFFICE
A148
EYE EXAM C1
B186
EYE EXAM C2
B185
MINOR PROCDURE
A183
GYN PROCEDURE
A167
ENT OFFICE
A170
CORRIDOR
B25
INTAKE
EVALUTATION
A143
CORRIDOR
AC111
EKG OFFICE
A155
EKG OFFICE
A156
CARDIOLOGY
OFFICE
A157
CARDIOLOGY
OFFICE
A158
HALL
AC113
EXAM
A159
EXAM
A160
EXAM
A161
PODIATRY EXAM
A162
Unoccupied
Unoccupied
PATIENT ED
CONFERENCE
A163
CHIROPRACTOR
ORTHO
A181
ORTHO CAST
A179
ORTHO EXAM
A178
STORAGE
OFFICE
STAIR
EXAM/CONSULT 2
A131
EXAM/CONSULT 1
A132
WOMEN'S EXAM
A133
EXAM/CONSULT 5
A127
EXAM/CONSULT 6
A126
EXAM/CONSULT 7
A125
EXAM/CONSULT 8
A124
P. TOILET
BARIATRIC
A134B
EXAM/CONSULT 3
A129
STAFF TOILET
A117
STAFF TOILET
A118
RECEPTION
A101
BARIATRIC TOILET
A104
REFRIG.
106-N
B43
A146
PT WORK AREA
A145
FAMILY TOILET
A105
P. TOILET
A149A
OFFICE
B1
TEAM WORK AREA
A136
MENS RESTROOM
A135
SCHEDULING
A133
ORTHO EXAM
A180
PODIATRY EXAM
A165
LAB
A149B
STORAGE
A164
ELEV.
TELEHEALTH
A187
CORRIDOOR
A113
P. TOILET
A130
UNISEX TOILET
A106
OFFICE
B7
WAITING
A197
CORRIDOR
AC109
HSK STROAGE
A198
EXAM/CONSULT 4
A128
LOCKERS
A116
EQUIP. STOR.
A120
WORK ROOM /
PATIENT
COUNSELLNG
A115
TELE HEALTH
A143
STORAGE
A110
P. TOILET
A142
DATA
A111
CONFERENCE/
BREAK
A112
STAIR 1
A102
ELEV.
A103
CORRIDOR/WAITING
A137
MED ROOM
A122
EXAM/CONSULT 9
A123
CLEAN SUPPLY
A121
CORRIDOR
AC112
COPIER/FAX
A136A
PROCEDURE
ROOM
A134
TEAM WORK AREA
A136
TEAM WORK AREA
A136
CORRIDOR
AC114
SOILED UTILITY
A173
VISITING
SPECIALIST
A177
EXAM
A175
OFFICE
A192
TELEHEALTH
A190
S T U V W
E-401
E-401
EX
EX
EX EX
EX
EX
EX
EX
EX
EX
EX EX
EX
EX
EX
EX
EX EX
EX
EX
EX
EX
EX
EX
EX
EXEX
EX
EX
EX
EX
EX
EX
EX
EX
EX EX
EX
'172-F3'- 37 '172-F3'- 33 '172-F3'- 29
'172-F3'- 10
'172-F3'- 25
'172-F3'- 2
'172-F3'- 43
'172-F3'- 12
'172-F3'- 47
'172-F3'- 20
'172-F3'- 14
'172-F3'- 16
'172-F3'- 18
PANEL
'172-F2'
'172-F3'- 1 '172-F3'- 5
'172-F3'- 13 '172-F3'- 21 '172-F3'- 9
'172-F3'- 45
'172-F3'- 40
'172-F3'- 42
'172-F2'- 24
'172-F3'- 24
'172-F3'- 28
'172-F3'- 26
'172-F3'- 32 '172-F3'- 36
'172-F3'- 34
'172-F3'- 30
'172-F3'- 46
'172-F2'- 9
'172-F2'- 7
'172-F2'- 5
'172-F2'- 11
'172-F3'- 17
'172-F3'- 38
PANEL
'172-F3'
'172-F2'- 26
'172-F2'- 15
E-401
SOILED HOLDING
A119
'172-F3'- 39
'172-F3'- 4
'172-F3'- 35
'172-F3'- 31
'172-F3'- 27
'172-F3'- 23
'172-F3'- 15
'172-F3'- 11
'172-F3'- 7
'172-F3'- 3
'172-F3'- 19 22
'172-F3'- 6
'172-F3'- 22
STORAGE
A108
SHARED MEDIA
ROOM
A107
CORRIDOOR
A114
ELEC.
A109
'172-F2'- 10
'172-F2'- 20
'172-F2'- 18
'172-F3'- 2
3 3 3
3 3 3
3 3
'172-F2'- 8
'172-F2'- 12
'172-F3'- 8
'172-F3'- 48
'172-F3'- 44
'172-F2'- 3
'172-F2'- 1
'172-F2'- 17
'172-F2'- 19
'172-F2'- 22
PANEL 'D'
PANEL 'D'
PANEL 'D'
PANEL 'D'
'172-F2'- 29
'172-F3'- 56
'172-F2'- 4
'172-F2'- 14
'172-F2'- 16
'172-F2'- 31
'172-F2'- 2
'172-F2'- 6
'172-F3'- 41
7 '172-B2'- 13
'172-F2'- 13
'172-F2'- 23 '172-F2'- 28
'172-F2'- 34
154 A
SADIE
PHARMACY
MED LAB
PROJECT
AREA
N
N
KEYPLANPLAN NORTHTRUE NORTH
# SHEET KEY NOTES:
SHEET NOTES:
WALL RATING LEGEND
1 HR FIRE SEPARATION
2 HR FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\s h a rm o n \D o c u m e n ts
\R e v it F ile s L o c a l\ -1
E le c tr ic a l M o d e l_ s h a rm o n A
C G
.r v t
/2
/2
:4
:0
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
FIRST FLOOR POWER PLAN
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
EP102
N
SCALE: 1/8" = 1'-0"EP102
1 FIRST FLOOR POWER PLAN
A.
B.
C.
D.
E.
F.
SEE E-401 FOR ELECTRICAL ROOM AND CLOSET
ENLARGEMENTS.
ALL RECEPTACLE CONDUCTORS ARE 2-12 AWG,
1-12 AWG EG IN 3/4" CONDUIT MINIMUM UNLESS
NOTED OTHERWISE.
COORDINATE LOCATION AND ELECTRICAL
REQUIREMENTS OF ALL MECHANICAL AND
PLUMBING EQUIPMENT WITH MECHANICAL AND
PLUMBING CONTRACTORS.
COORDINATE EQUIPMENT WITH ARCHITECTURAL
EQUIPMENT PLANS AND SCHEDULES.
ELECTRICAL CONTRACTOR SHALL FOLLOW SITE
LOCK-OUT/TAG-OUT GUIDELINES TO
DEENERGIZE EQUIPMENT.
ALL RECEPTACLES SHALL HAVE THEIR SOURCE
PANEL AND CIRCUIT NUMBER INDICATED ON
THEIR FACEPLATE.
1 JUNCTION BOX TO POWER CEILING-MOUNTED
OVERHEAD LIFT
2 POKE-THRU TO POWER EXAM TABLE.
CONNECT TO JUNCTION BOX UNDER FLOOR.
3 PROVIDE JUNCTION BOX TO POWER
LOW-VOLTAGE TRANSFORMER FOR
AUTOMATIC PLUMBING FIXTURES.
COORDINATE WITH PLUMBING CONTRACTOR.
4 PROVIDE JUNCTION BOX TO POWER
LOW-VOLTAGE TRANSFORMER MOUNTED IN
WALL WITH PANEL ACCESS FOR AUTOMATIC
PLUMBING FIXTURES. COORDINATE WITH
PLUMBING CONTRACTOR.
5 RECEPTACLES TO POWER OMNICELL
EQUIPMENT. COORDINATE FINAL PLACEMENT
OF RECEPTACLES WITH MANUFACTURER.
6 JUNCTION BOX TO POWER CEILING-MOUNTED
OVERHEAD PROJECTOR SCREEN.
COORDINATE WITH DEVICE MANUFACTURER.
7 120V 20A RECEPTACLE FOR MATV
EQUIPMENT
W
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
G
FI
W P
GFI
WP
GFI
WP
G
FI
W P
M
M
E
GFI
WP
M
E
E
E
M
E
E
E E
E
E
E
E
P Q R
S T U V W
E-401
PANEL
'172-R1'
'172-R1'- 42
172-AHU-1
172-HUH-3
172-HD-2
172-HUH-4
172-HD-1
172-CUAC-1
RELOCATED
ACCU
172-CU-1 172-CU-2
RELOCATED
ACCU
172-HWP-2
AHU PENTHOUSE
R104
STAIR
R102
'172-R1'- 20,22,24
'172-R1'- 25,27,29
'172-R1'- 14,16,18
'172-R1'- 19,21,23
'172-R3'- 3
'172-R3'- 2
'172-R1'- 7,9,11
'172-R1'- 13,15,17
'172-R1'- 26,28,30
'172-R3'- 9
172-CU-3
'172-R3'- 5
172-HWRP-1
172-HWRP-2
'172-R3'- 4
PANEL
'172-R3'
ELEV. MACHINE
R103
'172-R3'- 24
'172-R3'- 1
'172-R3'- 8
'172-R3'- 6
'172-R3'- 7
'172-R1'- 8,10,12
172-VAV-52
'172-R3'- 11
'172-F3'- 54 3
'172-R1'- 32,34,36
'172-R1'- 31,33,35
'172-R1'- 37,39,41
172-HWP-1
'172-R3'- 10,12,14
172-EF-5
172-EF-3
172-EF-2
172-EF-4
'172-R3'- 13,15
'172-R3'- 16,18
'172-R3'- 20,22
'172-R3'- 17,19,21
154 A
SADIE
PHARMACY
MED LAB
PROJECT
AREA
N N
KEYPLANPLAN NORTHTRUE NORTH
# SHEET KEY NOTES:
SHEET NOTES:
WALL RATING LEGEND
1 HR FIRE SEPARATION
2 HR FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\j m e ie r\ D o c u m e n ts
\1 -1
E le c tr ic a l M o d e l_ jm e ie r@ a c g -p a .c o m
.r v t
/1
/2
:1
:0
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
ROOF POWER PLAN
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
EP103
N
SCALE: 1/8" = 1'-0"EP103
1 ROOF POWER PLAN
A.
B.
C.
D.
E.
F.
ALL RECEPTACLE CONDUCTORS ARE 2-12
AWG, 1-12 AWG EG IN 3/4" CONDUIT MINIMUM
UNLESS NOTED OTHERWISE. REFERENCE
CONDUCTOR SCHEDULE ON SHEET E-602.
COORDINATE LOCATION AND ELECTRICAL
REQUIREMENTS OF ALL MECHANICAL AND
PLUMBING EQUIPMENT WITH MECHANICAL
AND PLUMBING CONTRACTORS.
ELECTRICAL CONTRACTOR SHALL FOLLOW
SITE LOCK-OUT/TAG-OUT GUIDELINES TO
DEENERGIZE EQUIPMENT.
ROUTE ALL CONDUIT UNDER ROOF.
ALL RECEPTACLES SHALL HAVE THEIR
SOURCE PANEL AND CIRCUIT NUMBER
INDICATED ON THEIR FACEPLATE.
COORDINATE PLACEMENT OF ALL UNIT-
MOUNTED DISCONNECT SWITCHES WITH UNIT
MANUFACTURER.
1 RELOCATED 'ACCU 1' TO BE FED FROM PANEL
R1. REFERENCE SHEET ED101
2 RELOCATED 'ACCU 2' TO BE REFED FROM
PANEL '154A-BF1' CIRCUIT 9 ON 300A
BREAKER. RUN 3-350 KCMIL AND 1-2 AWG EG
IN 3" CONDUIT FROM PANEL '154A-BF1'
CIRCUIT 9 TO 'ACCU 2' TO DISCONNECT
SWITCH MOUNTED ON UNIT AND WIRE
ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. REFERENCE SHEET ED101.
3 CIRCUIT TO POWER AHU INTERNAL LIGHTING
AND RECEPTACLES.
4 CONNECTION TO AHU. COORDINATE WORK
WITH MECHANICAL/HVAC CONTRACTORS AND
UNIT MANUFACTURER.
T T
TT
G
FI
G
FI
G
FI
GFI
GFIGFIGFI
G
FI
GFIGFIGFIG
FI
GFI GFI
GFIGFI
GFI GFI
M
M
E M
K L M N O P Q R
S T U V W
172-HUH-1
172-EF-1
172-HUH-2
G
G
E-401
'172-B1'- 3
BOUNDARY OF LIGHT FIXTURES
SERVED BY CIRCUIT INDICATED
(TYPICAL)
F
F
F
F
F
F F
F
F
F
FF
F
F
FF
FFF
'172-B1'- 1
'172-B1'- 1
E1
E2
E2E2
E2
'172-B2'- 1
'172-B2'- 5
'172-B2'- 12,14,16
NL
NL
NL
'172-B2'- 7 a b a a a a a a a a a b b b bb b b
'172-B2'- 2
'172-B2'- 4
'172-B2'- 3
172-FCU-1
'172-B2'- 15
154 A
SADIE
PHARMACY
MED LAB
PROJECT
AREA
N N
KEYPLANPLAN NORTHTRUE NORTH
# SHEET KEY NOTES:
SHEET NOTES:
WALL RATING LEGEND
1 HR FIRE SEPARATION
2 HR FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON DESIGN, INC
TEL: 317-800-6388
905 N CAPITOL AVE, SUITE 100
INDIANPOLIS, IN 46204
KARI ALLEN
Contract Number
Drawing Number
Building Number
VA259-17-C-0201
C U s e rs
\j m e ie r\ D o c u m e n ts
\1 -1
E le c tr ic a l M o d e l_ jm e ie r@ a c g -p a .c o m
.r v t
/1
/2
:1
:1
A
M
100% CONSTRUCTION
DOCUMENTS
JDMDS
CRAWLSPACE POWER AND
LIGHTING PLAN
07/13/2018
436-113CONSTRUCT PRIMARY CARE
MENTAL HEALTH INTEGRATION
EP104
N
SCALE: 1/8" = 1'-0"EP104
1 CRAWLSPACE POWER AND LIGHTING PLAN
A.
B.
C.
D.
E.
G.
H.
I.
J.
ALL RECEPTACLE CONDUCTORS ARE 2-12
AWG, 1-12 AWG EG IN 3/4" CONDUIT MINIMUM
UNLESS NOTED OTHERWISE.
COORDINATE LOCATION AND ELECTRICAL
REQUIREMENTS OF ALL MECHANICAL AND
PLUMBING EQUIPMENT WITH MECHANICAL AND
PLUMBING CONTRACTORS.
ALL LIGHTING CONDUCTORS SHALL BE 2-12
AWG, 1-12 AWG EG IN 3/4" CONDUIT UNLESS
NOTED OTHERWISE.
CONTRACTOR SHALL VERIFY COMPATIBILITY
OF ALL LIGHTING CONTROLS WITH THE LED
DRIVERS TO BE CONTROLLED.
COORDINATE ALL TIME DELAY, AUTO DIM,
PRESET DIMMING LEVELS, SENSOR
SENSITIVITY AND CONFIGURATIONS WITH THE
VA.
PROVIDE BACNET INTERFACE AND CONNECT
NEW ADDITION LIGHTING CONTROL SYSTEM TO
EXISTING BUILDING SCHNEIDER ELECTRIC
BUILDING AUTOMATION SYSTEM. COORDINATE
REQUIREMENTS WITH MANUFACTURER AND
VA.
ELECTRICAL CONTRACTOR SHALL FOLLOW
SITE LOCK-OUT/TAG-OUT GUIDELINES TO
DEENERGIZE EQUIPMENT.
ALL CRAWLSPACE UN-SWITCHED EXIT SIGNS,
NIGHT LIGHTS (NL), STAIRWELL LIGHTS, AND
EMERGENCY LIGHTING UNITS SHALL BE
CIRCUITED FROM LIGHTING CIRCUIT '154A-
EC5'-X, BUT AHEAD OF ANY CONTROLS OR
SWITCHING.
ALL RECEPTACLES SHALL HAVE THEIR
SOURCE PANEL AND CIRCUIT NUMBER
INDICATED ON THEIR FACEPLATE.
1 CONDUITS TERMINATING IN LOW VOLTAGE
SIDE OF UNDERGROUND JUNCTION BOX
BELOW TRANSFORMER. REFERENCE SINGLE
LINE ON SHEET E-601 AND DETAIL 3 ON E-501.
COORDINATE WITH MANUFACTURER OF
SELECTED TRANSFORMER.
2 LOCATION OF PANEL '172-SDB1' ON FIRST
FLOOR. REFER TO SINGLE LINE ON SHEET
E-601 FOR MORE ROUTING INFORMATION.
3 MV FEEDER TERMINATING INTO HV SIDE OF
TRANSFORMER JUNCTION BOX.
4 ROUTE ELECTRICAL CONDUIT BENEATH HVAC
AND PLUMBING. COORDINATE WITH OTHER
TRADES.
5 REFERENCE E-503 DETAIL 8 FOR POTENTIAL
PENETRATIONS THROUGH CONCRETE.
6 BID ALTERNATE 'D', SEE GI103 FOR MORE
INFORMATION. REDUCE LIGHTING IN
CRAWLSPACE.
REF.
R E
F
OSOS
VS
LVD
OS
OS
VS
VS
OS
VS VS
LVD
OS
LVD LVDLVD
L V
D
LV
V S
LVD
LV
LVD LVD
L V
D
OS
O S
LVD LVD LVD LVD LVD LVD
T
VS
VS VS VS
VS VS VSVSVS
VS
VS
VS
LVD VS
OS OS
LV
OSOSOSOS
VS
OS
OS
OS OS
OSOSOSOS
VS
OS OS
OS
OS
OS OS OS
OS
OS
OS
LVD LVD LVD
OS OSOSOS
L V
D
LVD
L V
D
VS
VS
VS
D
D
K L M N O P Q R
S T U V W
ELEV 1
B103
STAIR 1
B102
COFFEE
B100C
B-9
STORAGE
B31J
WORK ROOM
B31I
ELEV
B-13
B-11
EXAM/CONSULT 5
B129
EXAM/CONSULT 6
B128
EXAM/CONSULT 7
B127
EXAM/CONSULT 8
B126
P. TOILET
BARIATRIC
B136B
STAFF TOILET
B119
STAFF TOILET
B120
RECEPTION
B101
H.W. ALCOVE
B143
SHARED OFFICE
B108
P. TOILET
B132
EXAM/CONSULT 3
B131
PROCEDURE
ROOM
B136
EXAM/CONSULT 2
B133
EXAM/CONSULT 1
B134
WOMEN'S EXAM
B135
CORRIDOR
B115Unoccupied
Unoccupied
UNISEX TOILET
B106
OT
B31K
EXAM/CONSULT 4
B130
ELEC.
B111
EQUIP. STOR.
B122
CORRIDOR
B116
TELE HEALTH
B146
HSK
B112
P. TOILET
B145
DATA
B113
WORK ROOM /
PATIENT
COUNSELLING
B117
CONFERENCE/
BREAK
B114
MED ROOM
B124
EXAM/CONSULT 9
B125
CORRIDOR
B144
COPIER/FAX
B140
TEAM WORK AREA
B139
FIRE SPRINKLER
B137
CORRIDOR
B138
CRAWL SPACE
C101
RCD
RCD
RCDRCDRCDRCD
RCDRCDRCDRCDRCDRCD
RCD
RCD
REHABILITATION
SERVICES
B31A
RECEPT
B31C
OFFICE
B31G
OFFICE
B31D
HALLWAY
B31F
TELEMEDICINE
B31H
SPEECH
B31E
WAITING
B31B
IRM
B30
PT WORK AREA
B310
POOL THERAPY
B31P
EXAM
B31N
EXAM
B31M
EXAM
B31L
COMPRESSORS
B-12
BARIATRIC TOILET
B104
RCD
RCD
WAITING
B100
SHARED MED
STORAGE
B110
B B B B B B B B BB B B
G
B
B
B
B
B
B
B
B
B
B
B
B
B
B B
E1
E2
E2
BBBBBBB
E1
F
B
A A
B
B
B B B B B BF
A
B
B
B
B B B B B
B
B
B B B B C
C
A A
A
B B B BC
A A C
B B B B B B B
E2
B
BBBBBBBB
B
B
B
B
B B B B
C A A
B B B B
A
B
B
C
BBB
B
B
B
B E1E1
W1
KKKK
K
B
B
K K K K K K
K K
K
B B B B B
W1
E1
G
C
K
RCD2
B B
D
D
D
D
RCD2
NL NL
NL
NLNL
NL
NLNLNL
NL
'172-B1'- 3
'172-R2'- 10
'172-R2'- 10
SOILED HOLDING
B121
'172-B1'- 2
'172-B1'- 2
'172-B1'- 5
'172-B1'- 6
'172-B1'- 5
'172-B1'- 5
'172-B1'- 5 '172-B1'- 5
'172-B1'- 4 '172-B1'- 4
'172-B1'- 6
'172-B1'- 6
'172-B1'- 2
'172-B1'- 2
BOUNDARY OF LIGHT FIXTURES
SERVED BY CIRCUIT INDICATED
(TYPICAL)
E1
E2
EMR
B
B B B B B B B B
B B B B B B B B B B B B
B B
A
F
K
F
FAMILY TOILET
B105
1 1
B
CLEAN SUPPLY
B123
D
NL
NL
NL NL
NL
L L L
L
LL
L L
L W1
B
B
D
RCD
B
B
B
B
E1
TELE HEALTH
B109
SHARED OFFICE
B107 a b a a b b b b c c c c c c d d d d d d c d a,b
B a c c,d c,d d
154 A
SADIE
PHARMACY
MED LAB
PROJECT
AREA
N N
KEYPLANPLAN NORTHTRUE NORTH
# SHEET KEY NOTES:
SHEET NOTES:
WALL RATING LEGEND
1 HR FIRE SEPARATION
2 HR FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Project NumberProject Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
ROY STEINER, COR/PE
ENGINEERING/FMS
FORT HARRISON, MT.
FULLY SPRINKLERED
FORT HARRISON VAMC 172
APOGEE CONSULTING GROUP
TEL: 919-858-7420
151 KILDRAIRE FRAM ROAD, SUITE 120
CARY, NC 27511
GUIDON…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.