504-22-102_ELECTRICAL_CD_Signed_11.15.22.pdf
PDF 29 MB Posted
- Solicitation number
- 36C25723B0003
About this file
This solicitation is for electrical upgrades to freight elevators in Buildings 4 and 7 at a Veterans Affairs medical center. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17 is seeking proposals to replace the keying system for Project 671-22-196. Offerors should respond by the deadline of November 15, 2022, as indicated in the signed PDF file titled 504-22-102_ELECTRICAL_CD_Signed_11.15.22. Upgrades are needed for freight elevators in two buildings, and the project involves replacing the keying system. The solicitation number is 36C25723B0003 and is titled J056--504-22-102 Upgrade Freight Elevators Buildings 4 & 7.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S H E E T I N D E XG E N E R A L N O T E SA B B R E V I A T I O N S
1PH SINGLE-PHASE
1P SINGLE POLE
2/C TWO-CONDUCTOR
3/C THREE-CONDUCTOR
3PH THREE-PHASE
4/C FOUR-CONDUCTOR
4W FOUR-WIRE
A/C AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
AF AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER, AUTOMATIC
FREQUENCY CONTROL, OR AVAILABLE
FAULT CURRENT
AFCI ARC-FAULT CURRENT INTERRUPTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
Ah AMPERE HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE
AMB AMBIENT
AMP AMPERE
ARCH ARCHITECT
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BAT BATTERY
BD BOARD
BFF BELOW FINISH FLOOR
BLDG BUILDING
BRKR BREAKER
BYP BY PASS
C CONDUIT
CAB CABINET
CALC CALCULATE
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CD CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/
OWNER INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
C/B CIRCUIT BREAKER
CL CONNECTOR LIGHTING
CLF CURRENT LIMITING FUSE
CLG CEILING
CO CONDUIT ONLY
COAX COAX CABLE
COMM COMMUNICATION
COMPT COMPARTMENT
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
Cu COPPER
CUR CURRENT
dB DECIBEL
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DDC DIRECT DIGITAL CONTROLS
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISC DISCONNECT
DP DISTRIBUTION PANEL
DMR SW DIMMER SWITCH
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DRSW DOOR SWITCH
DS DISCONNECT SWITCH
DWG DRAWING
EC ELECTRICAL CONTRACTOR
EL ELEVATION OR EXISTING TO BE RELOCATED
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMER/EM EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
EN EXISTING IN NEW LOCATION
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
EPRF EXPLOSION PROOF
ER EXISTING TO REMAIN
ESMT EASEMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST(E) EXISTING
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FCIO FURNISHED BY CONTRACTOR,
INSTALLED BY OWNER
FOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTOR
FIXT FIXTURE
FLA FULL LOAD AMPS
FLUOR FLUORESCENT
FP FIRE PROTECTION
FT FEET OR FOOT
FU SW FUSED SWITCH
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
G ELECTRICAL GROUND
GEN GENERATOR
GFCI GROUND FAULT
CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTION
GND GROUND
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HZ HERTZ
IG ISOLATED GROUND
IESNA ILLUMINATION ENGINEERING
SOCIETY OF NORTH AMERICA
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
IWH INSTANTANEOUS WATER HEATER
J-BOX JUNCTION BOX
kV KILOVOLT kVA KILOVOLT AMPERE kVAh KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWh KILOWATT HOUR kWhM KILOWATT HOUR METER
LCP LIGHTING CONTROL PANEL
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LP LIGHT POLE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LT LIGHT
LTG LIGHTING
LTG PNL LIGHTING PANEL
LTNG LIGHTNING
LV LOW VOLTAGE
MAX MAXIMUM
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
MLO MAIN LUGS ONLY
MS MOTOR STARTER
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT
NA NOT APPLICABLE
NAC NOTIFICATION APPLIANCE CABINET
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NEUT, N NEUTRAL
NFC NOT FOR CONSTRUCTION
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OL OVERLOAD
OS OCCUPANCY SENSOR
P POLE
PB PULL BOX
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PIV POST INDICATOR VALVE
PF POWER FACTOR
PH PHASE
PNL PANEL
PS POWER SUPPLY
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
R EXISTING TO BE REMOVED
RCP REFLECTED CEILING PLAN
REC RECESSED
RECPT RECEPTACLE
RM ROOM
RMC RIGID METAL CONDUIT
RMS ROOT MEAN SQUARE
REQD REQUIRED
SAC SMALL APPLIANCE CIRCUIT
SCC SHORT CIRCUIT CAPACITY
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SM SMART METER
SPD SURGE PROTECTIVE DEVICE
SPEC SPECIFICATION
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD OR SB SWITCHBOARD
SWGR OR SG SWITCHGEAR
TEL TELEPHONE
TR TAMPER RESISTANT
TV TELEVISION
TYP TYPICAL
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER
POWER SUPPLY
UTIL UTILITY
V VOLT
VA VOLT AMPERE
VAR VOLT AMPERE REACTIVE
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
W WATT/WEATHERPROOF
(WHILE IN USE)
WH WATER HEATER
WP/W WEATHERPROOF
XFER TRANSFER
XFMR TRANSFORMER
1. THESE "GENERAL NOTES" SHALL APPLY TO ALL DRAWINGS WITHIN THIS DRAWING SET.
2. IF THE SPECIFICATIONS OR DRAWINGS CONFLICT WITH EACH OTHER THE MORE STRINGENT CRITERIA/SCOPE OF WORK SHALL BE REQUIRED.
3. BLACKENED OR BOLDED EQUIPMENT INDICATES THE EQUIPMENT SHALL BE PROVIDED OR MODIFIED UNLESS OTHERWISE NOTED.
4. EXISTING CIRCUITS ASSOCIATED WITH THE PROJECT AREA OF WORK ARE TO BE DE-ENERGIZED DURING CONSTRUCTION.
5. ALL ELECTRICAL WORK SHALL BE COMPLETED WITH ALL PROXIMATE ELECTRICAL CIRCUITS DE-ENERGIZED (i.e. A NEW BREAKER OR CIRCUIT CANNOT BE ADDED TO A PANEL UNLESS THE PANEL IS COMPLETELY DE-ENERGIZED), OR THE CONTRACTOR MUST COMPLY WITH NFPA 70E FOR WORK ON ENERGIZED SERVICE. THE VA WILL DETERMINE IF THE ELECTRICAL SERVICE CAN BE SHUT DOWN OR IT WILL HAVE TO BE WORKED HOT DEPENDING ON THE CRITICALITY OF THE AREA BEING AFFECTED. IF THE WORK MUST BE DONE WITH THE SERVICE LIVE, THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL REQUIRED PROTECTIVE TOOLS, EQUIPMENT, AND CLOTHING, AND MUST FOLLOW THE JOB SPECIFIC WORK PLAN PREPARED BY THE CONTRACTOR AND APPROVED BY THE VA. WORK THAT REQUIRES SHUTTING DOWN ELECTRICAL SERVICE MAY HAVE TO BE
ACCOMPLISHED DURING OTHER THAN NORMAL DUTY HOURS.
6. PROVIDE RACEWAYS AND CONDUCTORS/CABLING FROM LUMINAIRES TO THEIR CORRESPONDING CONTROL DEVICES AS INDICATED ON PLANS.
7. LUMINAIRE INSTALLATIONS AND LAYOUTS SHALL BE COORDINATED WITH ALL OBSTACLES, EQUIPMENT AND ARCHITECTURAL FEATURES.
8. WHERE NOT SPECIFICALLY INDICATED ON DRAWINGS, BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG MINIMUM FOR RUNS EQUAL TO OR LESS THAN 65 FEET AND 10 AWG MINIMUM FOR RUNS GREATER THAN 65 FEET. RACEWAYS AND CONDUCTORS SHALL BE SIZED AND QUANTIFIED TO SERVE AND CONTROL APPLICABLE EQUIPMENT WITH VOLTAGE DROP NO GREATER THAN THREE PERCENT. CONDUCTOR SIZE SHALL BE INCREASED TO COMPENSATE FOR DERATING REQUIRED PER NEC 310.15 WHERE MORE THAN THREE CURRENT CARRYING CONDUCTORS WITHIN ONE RACEWAY; CONDUCTOR AMPACITIES SHALL BE TAKEN FROM THE 75°C COLUMN. INDIVIDUAL CIRCUITS SHALL NOT SHARE
NEUTRAL CONDUCTORS.
9. MINIMUM CONDUIT SIZE SHALL BE 1” FOR EXTERIOR AND UNDERGROUND CONDUIT. MINIMUM CONDUIT SIZE SHALL BE 3/4” FOR INTERIOR CONDUIT. ADDITIONAL CONDUCTORS FOR UNSWITCHED HOT CONDUCTOR TO LUMINAIRES WITH EMERGENCY BATTERY POWERED BACKUP UNITS OR TRANSFER DEVICES SHALL BE PROVIDED. ALL CONDUIT SHALL BE CONCEALED. THE ABOVE COMMENTS SHALL BE ADHERED TO UNLESS OTHERWISE NOTED ON THE DRAWINGS.
10. EMERGENCY LIGHTING OR EQUIPMENT CIRCUITS SHALL BE ROUTED INDEPENDENT FROM OTHER CIRCUIT TYPES; ENSURE NEC 700.10 REQUIREMENTS ARE MET.
11. PROVIDE ALL CONDUIT AND WIRE FOR ALL CIRCUITS INDICATED AND/OR NOTED ON THE DRAWINGS AND/OR SPECIFICATIONS. ALL AUXILIARY OR REQUIRED APPURTENANCES
FOR PROVIDED EQUIPMENT SHALL BE PROVIDED WITH ALL CONNECTIONS AS REQUIRED.
12. ALL EQUIPMENT AND DEVICES INCLUDING, BUT NOT LIMITED TO, ELECTRICAL DISTRIBUTION EQUIPMENT, RECEPTACLES, DATA OUTLETS, AND SPECIAL SYSTEM DEVICES, SHALL HAVE THEIR EXACT LOCATION COORDINATED WITH ARCHITECTURAL DRAWINGS AND ALL TRADES PRIOR TO COMMENCING WORK.
13. COORDINATE WITH LIGHTING MANUFACTURER FOR ALL LIGHTING CONTROL EQUIPMENT AND APPURTENANCES; PROVIDE ANY ADDITIONAL SENSORS TO PROVIDE FULL COVERAGE OF THE SPACE AS REQUIRED. ALL CONDUIT, WIRE, POWER SUPPLIES, AND APPURTENANCES REQUIRED FOR THE LIGHTING CONTROL SYSTEM SHALL BE PROVIDED
TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL SYSTEM.
14. ALL EXTERIOR MOUNTED RECEPTACLES AND LUMINAIRE INSTALLATIONS SHALL COORDINATE EXACT LOCATIONS WITH ARCHITECTURAL SHEETS. ADDITIONALLY, WHERE MASONRY IS USED, SMOOTH BLOCK SHALL BE UTILIZED TO PROVIDE A PROPER MOUNTING SURFACE TO ALL EQUIPMENT; RECEPTACLES SHALL BE INSTALLED FLUSH.
15. ALL CONDUIT/SLEEVE FLOOR AND WALL PENETRATIONS SHALL BE SEALED WITH FIRE RATED ASSEMBLIES, CAULKING, AND APPURTENANCES. ELECTRICAL BOXES LOCATED IN
FIRE RATED WALLS SHALL BE RATED FOR USE IN FIRE RATED WALLS.
16. ALL EQUIPMENT AND INSTALLATION METHODS SHALL BE LISTED AND LABELED PER NEC, UL LISTED, OR REVIEWED EQUAL.
17. FOR ALL EQUIPMENT, COORDINATE WITH ALL TRADES (ARCHITECTURAL, MECHANICAL, PLUMBING, ETC) FOR ELECTRICAL REQUIREMENTS AND INSTALLATION LOCATIONS PRIOR
TO INSTALLATION.
18. ALL LOW-VOLTAGE SYSTEM CABLING NOT RAN IN CONDUIT TO WALL MOUNTED DEVICE SHALL HAVE A MINIMUM 1"C ROUTED FROM DEVICE THROUGH WALL INTO THE ACCESSIBLE CEILING SPACE; CABLING SHALL NOT BE ROUTED IN WALLS OR IN AN INACCESSIBLE LOCATION WITHOUT CONDUIT.
19. GFCI RECEPTACLES SHALL BE PROVIDED WITHIN 6’ OF A SINK/OR WATER SOURCE, WITHIN DAMP ROOMS, OR WHEN MOUNTED OUTDOORS/EXTERIOR TO THE BUILDING.
20. NO STRUCTURAL MEMBERS SHALL BE CUT, DRILLED, OR NOTCHED WITHOUT PRIOR WRITTEN CONSENT FROM THE STRUCTURAL ENGINEER OR ARCHITECT.
21. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL REFLECTED CEILING PLAN.
22. LIGHTING FIXTURES WITH MORE THAN TWO LAMPS SHALL HAVE TWO OUTER LAMPS CONTROLLED WITH ONE SWITCH AND INNER LAMP(S) CONTROLLED BY A SECOND SWITCH.
23. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC TABLE 250.122. ALL WIRING IS BASED ON Cu COPPER PER NEC TABLE 310.15(B)(16), USING 75°C AMPACITIES FOR FEEDERS.
24. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND NORMAL BRANCH WIRING DEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.
25. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES, WIRING DEVICES, CONDUITS, ETC., SHOWN ON PLANS TO BE REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE AREA OF WORK PERIMETER AND REMOVE CONDUIT WITHIN THE WORK AREA, DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE DEVICE AND REMOVE WIRING COMPLETELY
FROM THE ABANDONED CONDUITS.
26. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT PROTECTIVE DEVICE. COMPLETELY REMOVE ALL ABANDONED WIRING.
27. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS PASSING THROUGH RENOVATED AREAS AND SERVICING UNDISTURBED AREAS.
E-001 - ABBREVIATIONS, GENERAL NOTES, AND SHEET
INDEX
E-002 - ELECTRICAL LEGENDS
EP101 - BUILDING 4 - LEVEL 0 - ELECTRICAL PLAN
EP102 - BUILDING 4 - LEVEL 1 - ELECTRICAL PLAN
EP103 - BUILDING 4 - LEVEL 2 - ELECTRICAL PLAN
EP104 - BUILDING 7 - LEVEL B - ELECTRICAL PLAN
EP105 - BUILDING 7 - LEVEL 1 - ELECTRICAL PLAN
EP106 - BUILDING 7 - LEVEL 2 - ELECTRICAL PLAN
EP401 - BUILDING 4 - ENLARGED ELECTRICAL PLANS
EP402 - BUILDING 4 - ENLARGED ELECTRICAL PLANS
EP403 - BUILDING 7 - ENLARGED ELECTRICAL PLANS
E-601 - BUILDING 4 - ONE-LINE DIAGRAM
E-602 - BUILDING 7 - ONE LINE DIAGRAM
E-603 - ELECTRICAL SCHEDULES
E-604 - BUILDING 4 - ELECTRICAL LOAD SCHEDULES
E-605 - BUILDING 7 - ELECTRICAL LOAD SCHEDULES
28. PRIOR TO EQUIPMENT PROCUREMENT, CONTRACTOR SHALL PROVIDE DETAILED AND DIMENSIONED SHOP DRAWINGS INDICATING PROPOSED ELECTRICAL DISTRIBUTION EQUIPMENT LAYOUT FOR ALL ELECTRICAL EQUIPMENT INSTALLATIONS DURING THE SUBMITTAL PROCESS FOR VA AND ENGINEER REVIEW AND APPROVAL.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
Project Director
Revisions: Date:
UPGRADE FREIGHT ELEVATORS
BLDG 4 & 7
THOMAS E. CREEK, AMARILLO VA HEATLH CARE SYSTEM
6010 W AMARILLO BLVD, AMARILLO, TX
504-22-102
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REVISION 1 11.15.2022
E-001
ABBREVIATIONS, GENERAL NOTES,
AND SHEET INDEX
LRL/WNM JPS/FEB
CONSTRUCTION
DOCUMENTS
11/15/2022
SECTION A
XXX
SECTION LETTER
SHEET WHERE
SECTION IS TAKEN
FROM
A
XXX
SECTION LETTER
SHEET WHERE
SECTION IS TAKEN
FROM
XXX
DETAIL NUMBER
SHEET ON WHICH
DETAIL APPEARS
DETAIL AREA
SCALE
XXXNG
CONDUIT & WIRE TAG
(REFER TO CONDUIT
AND WIRE SCHEDULE)
XX FAULT CURRENT TAG
(3 PH, SYM AMPS)
1 KEY NOTE
XXX
FIGURE OR PHOTO
DETAIL NUMBER
IF PHOTO, ARROW
DENOTES DIRECTION
TAKEN
SHEET WHERE DETAIL
IS TAKEN FROM
DETAIL/PLAN
DETAIL/PLAN NUMBER
G E N E R A L S Y M B O L
D I V 2 6 - L E G E N D D I V 2 7 - L E G E N D D I V 2 8 - L E G E N D
G
PE
DS
X
X
X
ALL INTERIOR AREAS TO HAVE MANUAL 0N/AUTO OFF LIGHTING
CONTROL WITH THE USE OF DUAL TECHNOLOGY OCCUPANCY
SENSORS.
EXCEPT WHERE A WALL SWITCH OCCUPANCY SENSOR IS NOTED.
PHOTO ELECTRIC SENSOR
DAYLIGHT SENSOR FOR DAYLIGHT HARVESTING
CONTROL. SENSOR SHALL BE CEILING MOUNTED.
SWITCH, MULTIPOSITION
SWITCH, SINGLE BREAK
FUSE WITH RATING
NORMALLY CLOSED RELAY CONTACT
NORMALLY OPEN RELAY CONTACT
CIRCUIT BREAKER
DRAWOUT AIR CIRCUIT BREAKER
MOTOR, SINGLE-PHASE
MOTOR, THREE-PHASE
DELTA CONNECTION
TRANSFORMER
WYE CONNECTION
EARTH GROUND
JUNCTION BOX
PULL BOX
GENERATOR, POWER
BATTERY
CAPACITOR
RELAY; NUMBER INDICATES RELAY TYPE
50 = INSTANTANEOUS OVER CURRENT OR RATE-OF-RISE
51 = AC-TIME OVER CURRENT
67 = AC-DIRECTIONAL OVER CURRENT
86 = LOCKING OUT
DISCONNECT SWITCH, FUSED
DISCONNECT SWITCH, UNFUSED
STARTER, COMBINATION WITH DISCONNECT SWITCH
STARTER OR MOTOR CONTROLLER
METER
AMMETER
VOLTMETER
WATTMETER
WATT-HOUR METER
JUNCTION BOX
TRANSFORMER, PLAN
MOTOR
WYE CONNECTION
EARTH GROUND
LADDER CABLE TRAY
PULL BOX
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
RECEPTACLE, DUPLEX
RECEPTACLE, DUPLEX ON EMERGENCY POWER
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER
RECEPTACLE, QUADRUPLEX
RECEPTACLE
SINGLE
RECEPTACLE, SINGLE WITH SWITCH
RECEPTACLE, SPECIAL PURPOSE
A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R.
B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R.
C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R.
D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R.
E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R.
F = 208V, 30A, 3 PHASE, 3-POLE 4W, NEMA 15-30R.
G = 208V, 50A, 3 PHASE, 3 POLE, 4W, NEMA 15-30R.
H = 208V, 60A, 3 PHASE, 3 POLE, 4W, NEMA 15-60R.
RECEPTACLE, SWITCHED DUPLEX
DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE,
GROUNDING TYPE, 20A, W/#12 CONDUCTORS IN FLEXIBLE
CORD (CENTER LINE OF OUTLET: 6'-6" [1981mm] AFF. MINIMUM).
ELECTRICAL STRIP MOLD (OUTLETS ON 2'-0" [610mm]
CENTERS OR AS DESIGNATED ON DRAWINGS), MTD
3'-6" [1067mm] AFF OR AS INDICATED.
SWITCH
F = FUSED SWITCH K = KEY OPERATED
L = LOCK LM= LOW VOLTAGE MASTER
M = MANUAL MOTOR STARTING MC= MOMENTARY CONTACT
MP= MOTOR SNAP WITH PILOT LIGHT P = WITH PILOT LIGHT
(THERMAL TYPE)
PB= PUSH BUTTON STATION RC= REMOTE CONTROL
WP= WEATHER PROOF X = EXPLOSION PROOF
SWITCH, CEILING MOUNTED PULL
SWITCH (# SUBSCRIPT AS INDICATED BELOW):
BLANK = SINGLE POLE 2 = DOUBLE POLE
3 = THREE-WAY 4 = FOUR-WAY
D = DIMMER K = KEY OPERATED
LV= LOW VOLTAGE P = WITH PILOT LIGHT
LM= LOW VOLTAGE MASTER RC= REMOTE CONTROL
PB= PUSH BUTTON STATION WP= WEATHER PROOF
T = TIMER OPERATED Mo= OCCUPANCY SENSOR
RECESSED DOWNLIGHT FIXTURE, LETTER INDICATES TYPE.
LIGHT FIXTURE, RECESSED, 2'x4';
LETTER INDICATES TYPE.
LIGHT FIXTURE, RECESSED, 1'x4';
LETTER INDICATES TYPE.
LIGHT FIXTURE, RECESSED,1'x8'; LETTER INDICATES
TYPE.
LIGHT FIXTURE, SURFACE MOUNTED,2'x4';
LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED, 1'x4';
LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED,(1'x8');
LETTER INDICATES TYPE.
LIGHT FIXTURE,
EMERGENCY;
LETTER INDICATES
TYPE.
LIGHTING, ONE HEAD EMERGENCY BATTERY POWER
STREET LIGHT WITH BRACKET
LIGHT POLE, ONE LUMINAIRE
LIGHT POLE, TWO LUMINAIRES
LIGHT POLE, POST TOP MOUNT LUMINAIRE
LIGHTING WALL PACK, EXTERIOR BUILDING
LIGHTING, TWO HEAD EMERGENCY BATTERY POWER
LIGHTING, THREE HEAD EMERGENCY BATTERY POWER
EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL
ARROWS AND FACES AS SHOWN
EXIT SIGN, CEILING MOUNTED WITH
DIRECTIONAL ARROWS AND FACES AS SHOWN
LIGHT FIXTURE, RECESSED,2'x2'; LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED, 2'x2';
LETTER INDICATES TYPE.
LIGHT TRACK WITH HEADS AS SHOWN
STRIP LIGHTING, 4' LONG
LIGHT FIXTURE, WALL MOUNTED
LIGHT FIXTURE, BOLLARD
OUTLET, COMBINATION TELEPHONE/DATA COMMUNICATION
CABLE TELEVISION LINE = CATV
CLOSED CIRCUIT TELEVISION LINE = CCTV. MINIMUM 1" [25mm] CONDUIT
FIBEROPTICS LINE = FO
FLOOR RECEPTACLE, TELEPHONE
OUTLET TELEPHONE; LETTER INDICATES ASFOLLOWS:
J = JACK TYPE W = WALL TYPE
SPEAKER, CEILING MOUNTED, "X" INDICATES THE TYPE, PROVIDE SCHEDULE ON
LEGEND
SPEAKER, WALL MOUNTED, "X" INDICATES THE TYPE, PROVIDE SCHEDULE
ON LEGEND. MTD. 7'-6" [2286mm] AFF UNLESS OTHERWISE NOTED.
OUTLET DATA ONLY
TELEPHONE LINE = T
INTERCOM LINE = I. MINIMUM 3/4" [19mm] CONDUIT.
SOUND LINE = S
NURSE CALL LINE = NC. MINIMUM 3/4" [19mm] CONDUIT.
OUTLET; LETTER INDICATES AS FOLLOWS:
A = AUDIO V = VIDEO I = INTERCOM
RADIO CONDUIT RUN, MINIMUM 3/4" [19mm] CONDUIT.
RADIO CHANNEL SELECTOR FACILITIES, MTD. 4'-6" [1372mm] AFF UNLESS OTHERWISE
NOTED.
SPEAKER PROGRAM SELECTOR SWITCH & VOLUME
CONTROL MTD. 4'-6" [1372mm] AFF UNLESS OTHERWISE NOTED.
OUTLET, TELEVISION
BLANK = 4 11/16" [119mm] MASTER ANTENNA OUTLET BOX W/BLANK
COVER, MTD. 18" [457mm] AFF UNLESS OTHERWISE NOTED.
C = CAMERA (CCTV SYSTEM), MTD 18" [457mm] AFF
M = MONITOR (CTTV SYSTEM).
NURSE'S CALL MASTER STATION MTD ON
NURSE'S COUNTER TOP UNLESS OTHERWISE NOTED.
NURSE CALL TERMINAL CABINET.
NURSE CALL STATION.
2 = DUPLICATE FACILITIES FOR TWO BEDS (SEPARATE INDICATORS AT MASTER
STATION) MTD 5'-0" [1524mm] AFF UNLESS OTHERWISE NOTED.
D = DUTY STATION. MTD 5'-0" [1524mm] AFF UNLESS NOTED OTHERWISE.
E = MTD 6'-0" [1829mm] AFF FOR SHOWER LOCATION, MTD 4'-6" [1372mm] AFF FOR
TUB LOCATION, & MTD 3'-0" [914mm] AFF FOR TOILET LOCATION.
P = PSYCHIATRIC CORRIDOR STATION WITH KEY SWITCH
S = AUDIO VISUAL MALL STATION (STAFF) MTD 5'-0" [1524mm] AFF UNLESS
OTHERWISE NOTED.
U = UTILITY CALL STATION, MTD 5'-0" [1524mm] AFF UNLESS OTHERWISE NOTED.
NURSE CALL STATION.
2 = NURSE'S CALL DOME LIGHT (SUFFIX INDICATES No OF
LAMP) MTD 6" [152mm] ABOVE DOOR.
D = CORRIDOR DOME LIGHT.
I = AUXILIARY INTERSECTIONAL DOME LIGHT.
TELEPHONE TERMINAL CABINET
TELEPHONE BACKBOARD (WALL MOUNTED)
3-POLE TWIST-LOCK RECEPTACLE FOR MICROPHONE, MTD. 4'-6" 1372mm] AFF.
REMOTE DICTATING OUTLET MTD 1'-6" [457mm] AFF. UNLESS OTHERWISE NOTED.
INTERCOM STATION (REFER TO SPECS. FOR FUNCTIONAL
OPERATION OF INSTRUMENT & TYPE REQUIRED).
INTERCOM STAFF STATION.
TELECOMMUNICATIONS MANHOLE
POWER
LIGHTING
DATA/COMMUNICATION
x = LUMINAIRE SWITCH ZONE (ANY LOWER CASE LETTER APPLIES)
AUDIO DEVICE; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
B-BELL C-CHIME H-HORN K-KLAXON
L-LISTEN-IN M-MICROPHONE S-SOUNDER S-SPEAKER Z-BUZZER
BI-STATIC BEAM SENSOR; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
I-INFRARED M-MICROWAVE
F=FUNCTION
RX-RECEIVE TX-TRANSMIT
BIOMETRICS ACCESS CONTROL DEVICE; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
F-FINGER PRINT H-HAND GEOMETRY I-EYE IRIS
R-EYE RETINA V-VOICE
CARD ACCESS READER; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
B-BARCODE F-ELEVATOR FLOOR CALL H-ELEVATOR HALLCALL
M-MAG STRIP P-PROXIMITY S-SMART CARD
T-TOKEN
CARD READER WITH KEYPAD; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
CARD READER WITH TIME AND ATTENDANCE; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH
H-HIDDEN M-MULLIONP-PEDESTAL R-RACK
S-SURFACE W-WALLCENTRAL PROCESSING UNIT
CONTROL PANEL; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
B-BURGLAR D-DOOR F-FIRE P-PERIMETER
ELECTRONIC LOCK; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
D-DEADBOLT H-HYBRID L-LATCH SET M-MAGNETIC S-STRIKE
EXIT DEVICE; LETTER INDICATES AS FOLLOWS:
T=TECHNOLOGY/TYPE
D-DELAYED EGRESS E-ELECTRIFIED M-MECHANICAL X-HIGH SECURITY
FIBER OPTIC MODULE; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
R-RECEIVERT-TRANSCEIVER TX-TRANSMITTER
FIELD PANEL; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
A-ALARM C-CARD READER
GLASS BREAKAGE SENSOR; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
A-AUDIO S-SHOCK
INTERCOM; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
M-MASTER S-SUBSTATION
KEYBOARD
KEYPAD DEVICE; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
MONITOR; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
D-DATA G-GRAPHIC M-MULTISCREEN V-VIDEO
MOTION DETECTOR; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN
M-MULLIONP-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
D-DUAL TECHNOLOGY IR-INFRARED M-MICROWAVE U-ULTRASONIC
X-REQUEST-FOR-EXIT
RECORDER; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
A-AUDIO D-DIGITAL V-VIDEO
SECURITY ACCESS, ANNUNCIATOR PANEL
SECURITY ACCESS, BUZZER. MTD 1'-6" [457mm] AFF
UNLESS OTHERWISE NOTED
SECURITY ACCESS, CONTROL UNIT WITH
CLOSED CIRCUIT TELEVISION CAMERA
SECURITY ACCESS, GENERIC "X" INDICATES THE
TYPE, PROVIDE SCHEDULE OR LEGEND
SECURITY ACCESS, HORN OR SIREN
SECURITY ACCESS, OUTDOOR MICROWAVE TRANSMISSION UNIT
SECURITY ACCESS, PANIC ALARM
SECURITY ACCESS, VIDEO CAMERA WITH LENS
M = MOTION DETECTOR
PZ = MOTION DETECTOR WITH PAN AND ZOOM
PTZ= MOTION DETECTOR WITH PAN, TILT, AND ZOOM
SECURITY ACCESS, VOLUMETRIC SENSOR
SECURITY SCREEN WITH ALARM; LETTER INDICATES AS FOLLOWS:
T=TECHNOLOGY/TYPE
B-BLIND S-SHADE
SECURITY WINDOW SCREEN; LETTER INDICATES ASFOLLOWS:
T=TECHNOLOGY/TYPE
B-BLIND
VIDEO CONTROL KEYBOARD
VIDEO MOTION DETECTOR
SECURITY ACCESS, PANNING CAMERA TRAVERSE ANGLE
SECURITY ACCESS, SENSOR, BURIED VEHICULAR
SECURITY ACCESS, SWITCH, BALANCED MAGNETIC CONTROL
SECURITY ACCESS, TELEPHONE HANDSET
SECURITY ACCESS, VIDEO CAMERA WITH LENS, ANGLE OF VIEW
ALARM, CHECK VALVE
ALARM, FIRE, COMMUNICATOR
ALARM, FIRE, PANEL; LETTERS INDICATE AS FOLLOWS:
FACC = CENTRAL CONSOLE FACP = CONTROL PANEL
MFACP= MASTER CONTROL PANELFAAP = ANNUNCIATOR PANEL
ALARM, FIRE, MANUAL PULL STATION
ALARM, GONG
ALARM, HORN/LIGHT, ONE ASSEMBLY WITH CHIME
ALARM, HORN/LIGHT, SEPARATE ASSEMBLY
ALARM, LAMP LIGHT, SIGNAL LIGHT, STROBE
ALARM, MANUAL CONTROL
ALARM, MINI
HORN
ALARM, SPRINKLER SYSTEM WATER FLOW BELL
ALARM, TAMPER SWITCH
DETECTION, GAS
DETECTION, SMOKE CONTROL AND PRESSURE PANEL
DETECTION SWITCH, ABORT
DETECTION SWITCH, VALVE TAMPER
DETECTOR, FLAME FLICKER
DETECTOR, FLOW SWITCH
DETECTOR, HEAT
DETECTOR, HEAT; LETTER INDICATES AS FOLLOWS:
R/T = COMBINATION F = FIXED TEMPERATURE RISE
R/C = RATE COMPENSATION R = RATE OF
DETECTOR; LETTER INDICATES AS FOLLOWS:
BLANK = SMOKE DETECTOR
H = HEAT SMOKE
I = IONIZATION SMOKE
P = PHOTOELECTRIC SMOKE
IH = IONIZATION AND HEAT SMOKE
IP = IONIZATION AND PHOTOELECTRIC SMOKE
PH = PHOTOELECTRIC AND HEAT SMOKE
IPH = IONIZATION, PHOTOELECTRIC, AND HEAT
DETECTOR, SMOKE, FOR DUCT
DETECTOR, SWITCH LEVEL
PUSH BUTTON; LETTER INDICATES AS FOLLOWS:
M=MOUNT
C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION
P-PEDESTAL R-RACK S-SURFACE W-WALL
T=TECHNOLOGY/TYPE
B-BELL PUSH D-DURESS P-PANIC R-DOOR RELEASE
X-REQUEST-FOR-EXIT
CODE ONE CONTROL AND ALARM STATION. MTD 5'-0"
AFF UNLESS OTHERWISE NOTED.
CODE ONE TERMINAL CABINET.
CODE ONE ANNUNCIATOR PANEL.
CODE ONE BEDSIDE STATION.
CODE ONE DUTY STATION, MTD 5'-0" AFF UNLESS
OTHERWISE NOTED.
ALARM, FIRE; LETTERS INDICATE AS FOLLOWS:
BATT =BATTERIESCHR = CHARGER FAR = RECORDER
ALARM, FIRE, VALVE SUPERVISORY SWITCH.
ALARM, FIRE, TERMINAL CABINET.
ALARM, FIRE, POST INDICATOR VALVE.
ALARM, TRANSPONDER OR TRANSMITTER
ALARM, VOICE COMMUNICATION PANEL
FIRE ALARM STATION, MANUAL PULL
FIRE ALARM LINE = FA
ELECTROMAGNETIC TYPE DOOR HOLDER OUTLET
CITY FIRE ALARM MASTER STATION MTD 5'-6" [1676mm] AFF UNLESS
NOTED.
FIRE ALARM TRANSMITTER (BASE LOOP) NUMERALS DENOTE CODE.
FIRE ALARM TROUBLE TRANSMITTER (BASE LOOP) NUMERALS DENOTE
CODE.
ALARM, HORN/LIGHT, ONE ASSEMBLY C = WITH CHIME
360°
40°
X
M PTZ
FAT
2-4-6
FAT
2-4-6
AP
NIP
NIT
NIA
NI
NID
FAC
FACP
P
C
BATT
OSY
FATC
PIV
M
TS
FTR
SCCP
HD
R/T
HD
H
FS
N
TTB
A
J
S X
S X
M
N
R M
C
DH
S
A
B
C
A
B
C
D
E
E
PB
T
PB
S
S
R
R M
NCS
NCT
S
WB
M
T
M
T
M
F
T
M
T
T
M
M
M
M
T
T
M
T
M
T
M
T
M
T
M
M
T
M
T
M
T
M
T
T
T
CP
EPO
CONDUIT OR EQUIPMENT TO BE REMOVED
CONDUIT HOME RUN 3/4"C, 2#12 & 1#12 GND. UNLESS SHOWN
OTHERWISE. (EXAMPLE SHOWN: TO PANEL P1, CIRCUIT 3)
CONDUIT HOME RUN - SEE CONDUIT AND WIRE SCHEDULE
CONDUIT CONCEALED IN WALL, CEILING, UNDER FLOOR, IN
FLOOR
SLAB, OR ROUTED UNDERGROUND
CONDUIT CONCEALED WHERE POSSIBLE, OTHERWISE EXPOSED
EXTRA-HARD USAGE FLEXIBLE CORD
FLEXIBLE CONDUIT
CONDUIT TURNED UP OR TOWARD
CONDUIT TURNED DOWN OR AWAY
CONDUIT CAPPED
XXXX
P1-3
OS
FA FA
CATV
CCTV
FO
T
I
S
NC
R
J
M
A
V
W
WH
J
P
A
J
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
Project Director
Revisions: Date:
UPGRADE FREIGHT ELEVATORS
BLDG 4 & 7
THOMAS E. CREEK, AMARILLO VA HEATLH CARE SYSTEM
6010 W AMARILLO BLVD, AMARILLO, TX
504-22-102
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REVISION 1 11.15.2022 LRL/WNM JPS/FEB
CONSTRUCTION
DOCUMENTS
11/15/2022
E-002
ELECTRICAL LEGENDS
SWITCHBOARD
NO. 2
EXISTING ELEVATOR FEED FROM
480V EMERGENCY PANEL "1-BC13EC"
IN BUILDING 1 TO BE REPLACED.
EXISTING FEED TO
PENTHOUSE MCC
ELV
E F
G H J K L M N O
A B C D
ELECTRICAL
STORAGE
STORAGE
STORAGE
STORAGE
TE
LP
H O
N E
STEAM
1019A
STORAGE
MAILROOM
COPY ROOM
1016A
UNIFORMS
ELEC
1014A
OFFICE
1012A
PATIENT LIBRARY
DAV COUNCIL
1010C
DVA
1010B
TEXAS VET COMM
1010A
TRAINING
1008B
EMS OFFICE
STORAGE
1008A
KITCHEN
EMS EQUIPMENT
STORAGE
1009B
STORAGE
1009A
POLICE STORAGE
STORAGE
1005A
STORAGE
1005B
CANTEEN
STORAGE
1005D
MECHANICAL
DRUG CACHE
RESTROOM
RESTROOM
RECEIVING
OFFICE
1021B STORAGE
1009C STORAGE
1005C
ELEV 1
STORAGE
1000D
WAITING
CORRIDOR
ELEVATOR
MACHINE
ELEV 2
EP401
EP402
EP402
EP401
SWITCHBOARD NO. 1
XFMR 4-T2
TS-9
TS-10
MTS #14-1
PANEL 4-12
XFMR-4T1
ELV3
TO ELEVATOR 2
CONTROL SWITCH
"ECS-B4-2"
4B11EL2
4EQ2-9,11
CU-2
4EQ2-6
CONTINUE TO FC-2,
REFERENCE SHEET EP402
180°
4-B10EC
360°
360°
KEY PLAN
GENERAL NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE
INVESTIGATIONS AND RECORD DRAWINGS. IF
DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK,
PROMPTLY NOTIFY VA AND ENGINEER OF SAID
DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR
CLARITY. CONTRACTOR SHALL FIELD VERIFY ALL
CONTRACTOR DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED
WITH DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL
ASSOCIATED WITH WALLS BEING REMOVED AND IN ALL
LOCATIONS WHERE JUNCTION BOXES WILL NOT REMAIN
ACCESSIBLE AFTER INSTALLATION OF MILLWORK.
4. CONTRACTOR SHALL DISPOSE OF REMOVED DEVICES.
DISPOSAL OF DEVICES SHALL COMPLY WITH ALL
APPROPRIATE CODES.
5. PROTECT ALL EXISTING WORK FROM DAMAGE DURING
CONSTRUCTION. ANY DAMAGED MATERIALS, SYSTEMS,
COMPONENTS, FINISHES THE LIKE, SHALL BE REPAIRED OR
REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
6. FIELD VERIFY ALL RACEWAY DEMOLITION AND
INSTALLATIONS PRIOR TO PERFORMING WORK.
7. CONTRACTOR TO COORDINATE NORMAL/ESSENTIAL
ELECTRICAL SYSTEM SHUTDOWNS AND PHASING WITH THE
VA PRIOR TO PERFORMING REQUIRED EQUIPMENT
UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY
POWER AND DETERMINE TIE-IN/CONNECTION PLAN WITH
EXISTING EQUIPMENT. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
8. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO
MATCH EXISTING FIRE RATING OR NEW FIRE RATING, IF
REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWINGS
AS REQUIRED.
9. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT
PANEL DIRECTORIES FOR ALL PANELS THAT CONTAIN
CIRCUITS IMPACTED BY THIS PROJECT.
10. COORDINATE RACEWAY AND CABLING TERMINATION
LOCATIONS OF FIRE ALARM DEVICES IN FIELD WITH VA.
11. REFERENCE ONE-LINE DIAGRAM FOR ALL EQUIPMENT AND
PANEL FEEDER SIZING.
12. ALL SECURITY CAMERA INSTALLATIONS AND PROGRAMMING
SHALL BE PERFORMED BY AMARILLO VA SECURITY
CONTRACTOR "A-V CORP" OF AMARILLO, TX (806.379.7700).
KEY NOTES
REPLACE ELEVATOR LOBBY CONTROLS. COORDINATE WITH
ELEVATOR CONTRACTOR AND VENDOR AS REQUIRED.
PANEL TO BE MODIFIED. REFERENCE ONE-LINE DIAGRAM
ON SHEET E-601 FOR ADDITIONAL INFORMATION.
PROVIDE RACEWAY, CABLING, AND TERMINATIONS AS
REQUIRED FROM CAMERA TO EXISTING VA SURVEILLANCE
NETWORK SWITCH. CAMERA SHALL BE POE; PROVIDE ALL
POWER SUPPLIES AND/OR AMPLIFIERS AS REQUIRED FOR
A COMPLETE AND FULLY FUNCTIONAL SYSTEM. CAMERA
SHALL BE AXIS P3727-PLE.
EXISTING SWITHCHBOARD TO BE MODIFIED. REFERENCE
ONE-LINE DIAGRAM ON SHEET E-601 FOR ADDITIONAL
INFORMATION.
SCALE : 1/8" = 1'-0"
BUILDING 4 - LEVEL 0 - ELECTRICAL PLAN1
0 4' 8' 16'
PROJECT
NORTH
PROJECT
NORTH
AREA OF WORK
BLDG.4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
Project Director
Revisions: Date:
UPGRADE FREIGHT ELEVATORS
BLDG 4 & 7
THOMAS E. CREEK, AMARILLO VA HEATLH CARE SYSTEM
6010 W AMARILLO BLVD, AMARILLO, TX
504-22-102
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REVISION 1 11.15.2022
EP101
BUILDING 4 - LEVEL 0 - ELECTRICAL
PLAN
LRL/WNM JPS/FEB
CONSTRUCTION
DOCUMENTS
E F
G H J K L M N O
A B C D
8' -1
/6
4"
8' -0
KITCHEN
POT WASH
CENTER
SOILED
CAR WASH
CLEAN
PA
TI
EN
T
C
EN
TE
R
TR
A
Y
SE
R
VI
C E
CART STORAGE
ELEV 2
COOK'S COOLER
FOOD STORAGE
CONFERENCE
SECRETARY /
WAITING
CLINICAL
DIETITIANS
CLINICAL
DIETITIANS
SECTION CHIEF
NUTRITION
TECHNICIANS /
CLERKS
CONFERENCE
SUPERVISORS
NON-FOOD
STORAGE
C.E.F.
HAC
C O
R R
ID
O
R
SANITATION
SUPPLY
CHIEF
C H
IE
F
PR
O
G R
A M
M A
N A
G
EM
EN
T
CORRIDOR
STAFF LOCKERS
TOILET
TOILET
CORRIDOR
115CORRIDOR
NOURISHMENT
PREP
116 EP402
EP402
EP401
EP401
ELV
ELV
360°2
PTZM 1
SCALE : 1/8" = 1'-0"
BUILDING 4 - LEVEL 1 - ELECTRICAL PLAN1
0 4' 8' 16'
PROJECT
NORTH
PROJECT
NORTH
BLDG.4
AREA OF WORK
KEY PLAN
GENERAL NOTES
KEY NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE
INVESTIGATIONS AND RECORD DRAWINGS. IF DISCREPANCIES
ARE FOUND THAT MAY IMPACT WORK, PROMPTLY NOTIFY VA
AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR
CLARITY. CONTRACTOR SHALL FIELD VERIFY ALL
CONTRACTOR DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED
WITH DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL
ASSOCIATED WITH WALLS BEING REMOVED AND IN ALL
LOCATIONS WHERE JUNCTION BOXES WILL NOT REMAIN
ACCESSIBLE AFTER INSTALLATION OF MILLWORK.
4. CONTRACTOR SHALL DISPOSE OF REMOVED DEVICES.
DISPOSAL OF DEVICES SHALL COMPLY WITH ALL
APPROPRIATE CODES.
5. PROTECT ALL EXISTING WORK FROM DAMAGE DURING
CONSTRUCTION. ANY DAMAGED MATERIALS, SYSTEMS,
COMPONENTS, FINISHES THE LIKE, SHALL BE REPAIRED OR
REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
6. FIELD VERIFY ALL RACEWAY DEMOLITION AND
INSTALLATIONS PRIOR TO PERFORMING WORK.
7. CONTRACTOR TO COORDINATE NORMAL/ESSENTIAL
ELECTRICAL SYSTEM SHUTDOWNS AND PHASING WITH THE
VA PRIOR TO PERFORMING REQUIRED EQUIPMENT
UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY
POWER AND DETERMINE TIE-IN/CONNECTION PLAN WITH
EXISTING EQUIPMENT. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
8. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO
MATCH EXISTING FIRE RATING OR NEW FIRE RATING, IF
REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWING
AS REQUIRED.
9. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL
DIRECTORIES FOR ALL PANELS THAT CONTAIN CIRCUITS
IMPACTED BY THIS PROJECT.
10. COORDINATE RACEWAY AND CABLING TERMINATION
LOCATIONS OF FIRE ALARM DEVICES IN FIELD WITH VA.
11. REFERENCE ONE-LINE DIAGRAM FOR ALL EQUIPMENT AND
PANEL FEEDER SIZING.
12. ALL SECURITY CAMERA INSTALLATIONS AND PROGRAMMING
SHALL BE PERFORMED BY AMARILLO VA SECURITY
CONTRACTOR "A-V CORP" OF AMARILLO, TX (PH:
806.379.7700).
REPLACE ELEVATOR LOBBY CONTROLS. COORDINATE WITH
ELEVATOR CONTRACTOR AND VENDOR AS REQUIRED.
PROVIDE RACEWAY, CABLING, AND TERMINATIONS AS
REQUIRED FROM CAMERA TO EXISTING VA SURVEILLANCE
NETWORK SWITCH. CAMERA SHALL BE AXIS M5065(PTZ).
PROVIDED RACEWAY, CABLING, AND TERMINATIONS AS
REQUIRED FROM CAMERA TO EXISTING VA SURVEILLANCE
NETWORK SWITCH. CAMERA SHALL BE AXIS P3727-PLE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
Project Director
Revisions: Date:
UPGRADE FREIGHT ELEVATORS
BLDG 4 & 7
THOMAS E. CREEK, AMARILLO VA HEATLH CARE SYSTEM
6010 W AMARILLO BLVD, AMARILLO, TX
504-22-102
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REVISION 1 11.15.2022
EP102
BUILDING 4 - LEVEL 1 - ELECTRICAL
PLAN
LRL/WNM JPS/FEB
CONSTRUCTION
DOCUMENTS
E F
G H J K L M N O
A B C D
ACCESS HATCH
ELEVATOR 1
MACHINE ROOM
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE
INVESTIGATIONS AND RECORD DRAWINGS. IF
DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK,
PROMPTLY NOTIFY VA AND ENGINEER OF SAID
DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR
CLARITY. CONTRACTOR SHALL FIELD VERIFY ALL
CONTRACTOR DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED
WITH DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL
ASSOCIATED WITH WALLS BEING REMOVED AND IN ALL
LOCATIONS WHERE JUNCTION BOXES WILL NOT REMAIN
ACCESSIBLE AFTER INSTALLATION OF MILLWORK.
4. CONTRACTOR SHALL DISPOSE OF REMOVED DEVICES.
DISPOSAL OF DEVICES SHALL COMPLY WITH ALL
APPROPRIATE CODES.
5. PROTECT ALL EXISTING WORK FROM DAMAGE DURING
CONSTRUCTION. ANY DAMAGED MATERIALS, SYSTEMS,
COMPONENTS, FINISHES THE LIKE, SHALL BE REPAIRED OR
REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
6. FIELD VERIFY ALL RACEWAY DEMOLITION AND
INSTALLATIONS PRIOR TO PERFORMING WORK.
7. CONTRACTOR TO COORDINATE NORMAL/ESSENTIAL
ELECTRICAL SYSTEM SHUTDOWNS AND PHASING WITH THE
VA PRIOR TO PERFORMING REQUIRED EQUIPMENT
UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY
POWER AND DETERMINE TIE-IN/CONNECTION PLAN WITH
EXISTING EQUIPMENT. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
8. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO
MATCH EXISTING FIRE RATING OR NEW FIRE RATING, IF
REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWINGS
AS REQUIRED.
9. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT
PANEL DIRECTORIES FOR ALL PANELS THAT CONTAIN
CIRCUITS IMPACTED BY THIS PROJECT.
10. COORDINATE RACEWAY AND CABLING TERMINATION
LOCATIONS OF FIRE ALARM DEVICES IN FIELD WITH VA.
11. REFERENCE ONE-LINE DIAGRAM FOR ALL EQUIPMENT AND
PANEL FEEDER SIZING.
12. ALL SECURITY CAMERA INSTALLATIONS AND PROGRAMMING
SHALL BE PERFORMED BY AMARILLO VA SECURITY
CONTRACTOR "A-V CORP" OF AMARILLO, TX (806.379.7700).
EXISTING MOTOR CONTROL CENTER "MCC-4" PROVIDING
POWER TO ELEVATOR 1 (BUILDING 4) TO BE MODIFIED
FOR ELEVATOR REPLACEMENT. SEE ONELINE DIAGRAM ON
SHEET E-601 FOR ADDITIONAL INFORMATION.
SCALE : 1/8" = 1'-0"
BUILDING 4 - LEVEL 2 - ELECTRICAL PLAN1
0 4' 8' 16'
PROJECT
NORTH
PROJECT
NORTH
EXISTING FEEDER
FOR ELEVATOR 1
BLDG.4
EP401
EP401
AREA OF WORK
CONTINUE TO ELEVATOR
CONTROL SWITCH "ECS-B4-1"
KEY PLAN
GENERAL NOTES
KEY NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
Project Director
Revisions: Date:
UPGRADE FREIGHT ELEVATORS
BLDG 4 & 7
THOMAS E. CREEK, AMARILLO VA HEATLH CARE SYSTEM
6010 W AMARILLO BLVD, AMARILLO, TX
504-22-102
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REVISION 1 11.15.2022
EP103
BUILDING 4 - LEVEL 2 - ELECTRICAL
PLAN
LRL/WNM JPS/FEB
CONSTRUCTION
DOCUMENTS
E F G H
A B C D
STORAGE
MECHANICAL
4A
STORAGE
OFFICE
STORAGE
OFFICE
ELECTRICAL
MECHANICAL
B03A
ELEVATOR 1
PARTIALLY
EXCAVATED
PARTIALLY
EXCAVATED
PARTIALLY
EXCAVATED
OFFICE
2A
OFFICE
2PNL 7-B3EC
SPLICE BOX
PNL 7B2
PNL 7B3
PNL 7-B1EQ
PNL 73BL
GROUNDING BAR
T
7-B2EQ
TX-7B2EQ
CARD READER
CONTROL PANELS
180°
ELV
SCALE : 1/4" = 1'-0"
BUILDING 7 - LEVEL B - ELECTRICAL PLAN1
PROJECT
NORTH
EP403
EP403
3360°
2'0 4' 8'
KEY PLAN
GENERAL NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE
INVESTIGATIONS AND RECORD DRAWINGS. IF
DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK,
PROMPTLY NOTIFY VA AND ENGINEER OF SAID
DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR
CLARITY. CONTRACTOR SHALL FIELD VERIFY ALL
CONTRACTOR DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED
WITH DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL
ASSOCIATED WITH WALLS BEING REMOVED AND IN ALL
LOCATIONS WHERE JUNCTION BOXES WILL NOT REMAIN
ACCESSIBLE AFTER INSTALLATION OF MILLWORK.
4. CONTRACTOR SHALL DISPOSE OF REMOVED DEVICES.
DISPOSAL OF DEVICES SHALL COMPLY WITH ALL
APPROPRIATE CODES.
5. PROTECT ALL EXISTING WORK FROM DAMAGE DURING
CONSTRUCTION. ANY DAMAGED MATERIALS, SYSTEMS,
COMPONENTS, FINISHES THE LIKE, SHALL BE REPAIRED OR
REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
6. FIELD VERIFY ALL RACEWAY DEMOLITION AND
INSTALLATIONS PRIOR TO PERFORMING WORK.
7. CONTRACTOR TO COORDINATE NORMAL/ESSENTIAL
ELECTRICAL SYSTEM SHUTDOWNS AND PHASING WITH THE
VA PRIOR TO PERFORMING REQUIRED EQUIPMENT
UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY
POWER AND DETERMINE TIE-IN/CONNECTION PLAN WITH
EXISTING EQUIPMENT. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
8. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO
MATCH EXISTING FIRE RATING OR NEW FIRE RATING, IF
REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWINGS
AS REQUIRED.
9. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT
PANEL DIRECTORIES FOR ALL PANELS THAT CONTAIN
CIRCUITS IMPACTED BY THIS PROJECT.
10. COORDINATE RACEWAY AND CABLING TERMINATION
LOCATIONS OF FIRE ALARM DEVICES IN FIELD WITH VA.
11. REFERENCE ONE-LINE DIAGRAM FOR ALL EQUIPMENT AND
PANEL FEEDER SIZING.
12. ALL SECURITY CAMERA INSTALLATIONS AND PROGRAMMING
SHALL BE PERFORMED BY AMARILLO VA SECURITY
CONTRACTOR "A-V CORP" OF AMARILLO, TX (806.379.7700).
KEY NOTES
REPLACE ELEVATOR LOBBY CONTROLS. COORDINATE WITH
ELEVATOR CONTRACTOR AND VENDOR AS REQUIRED.
PANEL TO BE MODIFIED. REFERENCE ONE-LINE DIAGRAM
ON SHEET E-601 FOR ADDITIONAL INFORMATION.
PROVIDE RACEWAY, CABLING, AND TERMINATIONS AS
REQUIRED FROM CAMERA TO EXISTING VA SURVEILLANCE
NETWORK SWITCH. CAMERA SHALL BE POE; PROVIDE ALL
POWER SUPPLIES AND/OR AMPLIFIERS AS REQUIRED FOR
A COMPLETE AND FULLY FUNCTIONAL SYSTEM. CAMERA
SHALL BE AXIS P3727-PLE.
INSTALL MODULES AS NEEDED TO SERVE CARD READER
FOR BUILDING 7 ELEVATOR MACHINE ROOM. COORDINATE
WITH VA AS REQUIRED.
PROJECT
NORTH
AREA OF WORK
BLDG.7
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
Project Director
Revisions: Date:
UPGRADE FREIGHT ELEVATORS
BLDG 4 & 7
THOMAS E. CREEK, AMARILLO VA HEATLH CARE SYSTEM
6010 W AMARILLO BLVD, AMARILLO, TX
504-22-102
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REVISION 1 11.15.2022
EP104
LRL/WNM JPS/FEB
CONSTRUCTION
DOCUMENTS
11/15/2022
BUILDING 7 - LEVEL B - ELECTRICAL
PLAN
A B C 108B D E F G H
110A
106B
111A
108A 114
ELEVATOR 1
106A
111B REPLACE ELEVATOR LOBBY CONTROLS. COORDINATE WITH
ELEVATOR CONTRACTOR AND VENDOR AS REQUIRED.
PROVIDE RACEWAY, CABLING, AND TERMINATIONS AS
REQUIRED FROM CAMERA TO EXISTING VA SURVEILLANCE
NETWORK SWITCH. CAMERA SHALL BE POE; PROVIDE ALL
POWER SUPPLIES AND/OR AMPLIFIERS AS REQURED FOR A
COMPLETE AND FULLY FUNCTIONAL SYSTEM. CAMERA
SHALL BE AXIS P3727-PLE.
ELV 1
SCALE : 1/4" = 1'-0"
BUILDING 7 - LEVEL 1 - ELECTRICAL PLAN1
0 2' 4' 8'
PROJECT
NORTH
PROJECT
NORTH
AREA OF WORK
360°
360° 2
KEY PLAN
GENERAL NOTES
KEY NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE
INVESTIGATIONS AND RECORD DRAWINGS. IF DISCREPANCIES
ARE FOUND THAT MAY IMPACT WORK, PROMPTLY NOTIFY VA
AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR
CLARITY. CONTRACTOR SHALL FIELD VERIFY ALL
CONTRACTOR DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED
WITH DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL
ASSOCIATED WITH WALLS BEING REMOVED AND IN ALL
LOCATIONS WHERE JUNCTION BOXES WILL NOT REMAIN
ACCESSIBLE AFTER INSTALLATION OF MILLWORK.
4. CONTRACTOR SHALL DISPOSE OF REMOVED DEVICES.
DISPOSAL OF DEVICES SHALL COMPLY WITH ALL
APPROPRIATE CODES.
5. PROTECT ALL EXISTING WORK FROM DAMAGE DURING
CONSTRUCTION. ANY DAMAGED MATERIALS, SYSTEMS,
COMPONENTS, FINISHES THE LIKE, SHALL BE REPAIRED OR
REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
6. FIELD VERIFY ALL RACEWAY DEMOLITION AND
INSTALLATIONS PRIOR TO PERFORMING WORK.
7. CONTRACTOR TO COORDINATE NORMAL/ESSENTIAL
ELECTRICAL SYSTEM SHUTDOWNS AND PHASING WITH THE
VA PRIOR TO PERFORMING REQUIRED EQUIPMENT
UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY
POWER AND DETERMINE TIE-IN/CONNECTION PLAN WITH
EXISTING EQUIPMENT. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
8. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO
MATCH EXISTING FIRE RATING OR NEW FIRE RATING, IF
REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWING
AS REQUIRED.
9. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL
DIRECTORIES FOR ALL PANELS THAT CONTAIN CIRCUITS
IMPACTED BY THIS PROJECT.
10. COORDINATE RACEWAY AND CABLING TERMINATION
LOCATIONS OF FIRE ALARM DEVICES IN FIELD WITH VA.
11. REFERENCE ONE-LINE DIAGRAM FOR ALL EQUIPMENT AND
PANEL FEEDER SIZING.
12. ALL SECURITY CAMERA INSTALLATIONS AND PROGRAMMING
SHALL BE PERFORMED BY AMARILLO VA SECURITY
CONTRACTOR "A-V CORP" OF AMARILLO, TX (PH:
806.379.7700).
BLDG.7
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
Project Director
Revisions: Date:
UPGRADE FREIGHT ELEVATORS
BLDG 4 & 7
THOMAS E. CREEK, AMARILLO VA HEATLH CARE SYSTEM
6010 W AMARILLO BLVD, AMARILLO, TX
504-22-102
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REVISION 1 11.15.2022
EP105
LRL/WNM JPS/FEB
CONSTRUCTION
DOCUMENTS
11/15/2022
BUILDING 7 - LEVEL 1 - ELECTRICAL
E F G H
A B C D
ELEVATOR
CHIEF
SECRETARY
ISC
203 PROGRAM
COMPUTER
ROOM
RESTROOM
MECHANICAL
207A
HAC
HALL
PRIVATE ROOM
208A
ELV 1
SCALE : 1/4" = 1'-0"
BUILDING 7 - LEVEL 2 - ELECTRICAL PLAN1
PROJECT
NORTH
EP403
EP403
360° 2 360°
2'0 4' 8'
REPLACE ELEVATOR LOBBY CONTROLS. COORDINATE WITH
ELEVATOR CONTRACTOR AND VENDOR AS REQUIRED.
PROVIDE RACEWAY, CABLING, AND TERMINATIONS AS
REQUIRED FROM CAMERA TO EXISTING VA SURVEILLANCE
NETWORK SWITCH. CAMERA SHALL BE POE; PROVIDE ALL
POWER SUPPLIES AND/OR AMPLIFIERS AS REQURED FOR A
COMPLETE AND FULLY FUNCTIONAL SYSTEM. CAMERA
SHALL BE AXIS P3727-PLE.
KEY PLAN
GENERAL NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE
INVESTIGATIONS AND RECORD DRAWINGS. IF
DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK,
PROMPTLY NOTIFY VA AND ENGINEER OF SAID
DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR
CLARITY. CONTRACTOR SHALL FIELD VERIFY ALL
CONTRACTOR DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED
WITH DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL
ASSOCIATED WITH WALLS BEING REMOVED AND IN ALL
LOCATIONS WHERE JUNCTION BOXES WILL NOT REMAIN
ACCESSIBLE AFTER INSTALLATION OF MILLWORK.
4. CONTRACTOR SHALL DISPOSE OF REMOVED DEVICES.
DISPOSAL OF DEVICES SHALL COMPLY WITH ALL
APPROPRIATE CODES.
5. PROTECT ALL EXISTING WORK FROM DAMAGE DURING
CONSTRUCTION. ANY DAMAGED MATERIALS, SYSTEMS,
COMPONENTS, FINISHES THE LIKE, SHALL BE REPAIRED OR
REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
6. FIELD VERIFY ALL RACEWAY DEMOLITION AND
INSTALLATIONS PRIOR TO PERFORMING WORK.
7. CONTRACTOR TO COORDINATE NORMAL/ESSENTIAL
ELECTRICAL SYSTEM SHUTDOWNS AND PHASING WITH THE
VA PRIOR TO PERFORMING REQUIRED EQUIPMENT
UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY
POWER AND DETERMINE TIE-IN/CONNECTION PLAN WITH
EXISTING EQUIPMENT. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
8. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO
MATCH EXISTING FIRE RATING OR NEW FIRE RATING, IF
REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWINGS
AS REQUIRED.
9. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT
PANEL DIRECTORIES FOR ALL PANELS THAT CONTAIN
CIRCUITS IMPACTED BY THIS PROJECT.
10. COORDINATE RACEWAY AND CABLING TERMINATION
LOCATIONS OF FIRE ALARM DEVICES IN FIELD WITH VA.
11. REFERENCE ONE-LINE DIAGRAM FOR ALL EQUIPMENT AND
PANEL FEEDER SIZING.
12. ALL SECURITY CAMERA INSTALLATIONS AND PROGRAMMING
SHALL BE PERFORMED BY AMARILLO VA SECURITY
CONTRACTOR "A-V CORP" OF AMARILLO, TX (806.379.7700).
KEY NOTES
PROJECT
NORTH
AREA OF WORK
BLDG.7
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
Project Director
Revisions: Date:
UPGRADE FREIGHT ELEVATORS
BLDG 4 & 7
THOMAS E. CREEK, AMARILLO VA HEATLH CARE SYSTEM
6010 W AMARILLO BLVD, AMARILLO, TX
504-22-102
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REVISION 1 11.15.2022
EP106
LRL/WNM JPS/FEB
CONSTRUCTION
DOCUMENTS
11/15/2022
BUILDING 7 - LEVEL 2 - ELECTRICAL
G H
SWITCH
ELEVATOR 1
MACHINE ROOM
THRESHOLD.
M J
G H
ELEVATOR 1
MACHINE ROOM
SCALE : 1/2" = 1'-0"
BUILDING 4 - LEVEL 0 - ELEVATOR 1 PIT
ENLARGED DEMOLITION PLAN1
EP101 SCALE : 1/2" = 1'-0"
BUILDING 4 - LEVEL 1 - ELEVATOR 1 TOP OF
HOISTWAY ENLARGED DEMOLITION PLAN2
EP102
PROJECT
NORTH
SHOWN AREA
EXISITING ELECTRICAL EQUIPMENT AND ASSOCIATED
CONDUIT AND WIRE TO BE DEMOLISHED BACK TO
SOURCE, UNLESS NOTED OTHERWISE.
1. PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND
RECORD DRAWINGS. IF DISCREPANCIES ARE FOUND THAT
MAY IMPACT WORK, PROMPTLY NOTIFY VA AND ENGINEER
OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR
CLARITY. CONTRACTOR SHALL FIELD VERIFY ALL POWER
AND SIGNAL DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED
WITH DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. PROTECT ALL EXISTING WORK FROM DAMAGE DURING
CONSTRUCTION. ANY DAMAGED MATERIALS, SYSTEMS,
COMPONENTS, FINISHES THE LIKE, SHALL BE REPAIRED OR
REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
4. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO
MATCH EXISTING FIRE RATING OR NEW FIRE RATING, IF
REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWING
AS REQUIRED.
5. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT
PANEL DIRECTORIES FOR ALL PANELS THAT CONTAIN
CIRCUITS IMPACTED BY THIS PROJECT.
6. ALL FIRE ALARM FIELD DEVICES SHALL INTERFACE WITH
EXISTING FIRE ALARM ZONE AS REQUIRED.
7. ALL SURVEILLANCE CAMERAS SHALL BE NETWORKED WITH
EXISTING IT NETWORK.
8. REFERENCE ONE-LINE DIAGRAM FOR ALL EQUIPMENT AND
PANEL FEEDER SIZING.
9. SECURITY CAMERA, CAMERA INSTALLATION, AND
SURVEILLANCE SYSTEM PROGRAMMING SHALL BE
PERFORMED BY AMARILLO VA SECURITY CONTRACTOR "A-V
CORP" OF AMARILLO, TX (PH: 806.379.7700).
SCALE : 1/2" = 1'-0"
BUILDING 4 - LEVEL 0 - ELEVATOR 1 PIT
ENLARGED ELECTRICAL PLAN4
EP101 SCALE : 1/2" = 1'-0"
BUILDING 4 - LEVEL 1 - ELEVATOR 1 TOP OF
HOISTWAY ENLARGED ELECTRICAL PLAN5
EP102
SCALE : 1/2" = 1'-0"
BUILDING 4 - LEVEL 2 - ELEVATOR 1 MACHINE
ROOM ENLARGED DEMOLITION PLAN3
EP103
SCALE : 1/2" = 1'-0"
BUILDING 4 - LEVEL 2 - ELEVATOR 1 MACHINE
ROOM ENLARGED ELECTRICAL PLAN6
EP103
H
H
G
G
HG
HG
DISCONNECT
MITSUBISHI
CONTROL PANELCOURION CONTROL
PANEL
DOOR POWER RESET
DISCONNECT SWITCH
HYDRAULIC UNIT
J
EXISTING ELEVATOR CAB AND ALL RELATED ELECTRICAL
EQUIPMENT TO BE DEMOLISHED AND REMOVED, UNLESS
SHOWN OTHERWISE.
EXISTING NON-GFCI RECEPTACLE AND BOX TO BE
REPLACED WITH 20A, 120V, DUPLEX, GFCI, TR, WR
RECEPTACLE WITH WHILE-IN-USE DIE-CAST ALUMINUM
COVER. EXISTING CONDUIT AND WIRING TO BE REUSED
AND EXTENDED AS REQUIRED. REFERENCE DETAIL '4' ON
THIS SHEET FOR ADDITIONAL INFORMATION.
PROVIDE (5) JUNCTION BOXES (MINIMUM) AND REQUIRED
CONDUIT AND WIRING FOR ELEVATOR AND FIRE ALARM
SYSTEM INTERFACING. JUNCTION BOXES SHALL PROVIDE
INTERFACING RECALLS INCLUDING, BUT NOT LIMITED TO,
THE FOLLOWING: PRIMARY, ALTERNATE, MACHINE ROOM,
HOISTWAY, AND SHUNT TRIP. COORDINATE WITH ELEVATOR
MANUFACTURER, INSTALLER, AND AHJ FOR A FULLY
FUNCTIONAL SYSTEM AS REQUIRED.
CIRCUIT TO EXISTING PIT RECEPTACLE AND LIGHTING