A0005_AE503 AMEND 0003.pdf
PDF 530 KB Posted
- Solicitation number
- 36C25622R0140
About this file
This federal solicitation is for the construction of an approximately 2,600 gross square foot inpatient dialysis facility at the North Little Rock VA Medical Center in Arkansas. Key requirements include general construction work across multiple divisions such as concrete, masonry, metals, wood, thermal and moisture protection, openings, finishes, specialties, and mechanical, electrical and plumbing systems. Offerors must provide a price breakdown and total proposed cost for all labor, materials and equipment for the base project. The solicitation also specifies applicable federal agencies as the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The response deadline and award date are not stated.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CORNER BEAD
EXISTING STEEL LINTEL
EXISTING CONSTRUCTION
CONTINUOUS BACKER ROD
& SEALANT
AT CEILING AS
SCHEDULED
INTERIOR EXTERIOR
CONTINUOUS
CAULK JT
FILL EXISTING STUD
CAVITY w/ R-19 BATT
INSULATION
NEW 5/8" GYP BOARD OVER ALL
EXPOSED EXTERIOR WALL
SURFACES WHERE EXISTING
GWB REMOVED
ALUMINUM STOREFRONT
FRAMING
AS SCHEDULED
2 1/2"
BLAST-RESISTANT
INSULATING GLAZING
UNIT AS SCHEDULED
F.V.
5"
EXISTING
CONSTRUCTION
NEW 3/4" FRT
PLYWOOD
3/4" SOLID SURFACE
SILL & STOOL (SS-01)
PTN TYPE M_1e TO
SILL HEIGHT
EXISTING
CONSTRUCTION
(REPLACE EXISTING SILL
TRACK w/ NEW)
CONTINUOUS BACKER
ROD & SEALANT
ALUMINUM
STOREFRONT FRAMING
AS SCHEDULED
BLAST-RESISTANT
INSULATING GLAZING
UNIT AS SCHEDULED
INTERIOR EXTERIOR
CONTINUOUS
CAULK JT
2 1/2"
F.V.
5"
SILL FLASHING
1 1/4" 4 1/4"
INTERIOR EXTERIOR
F.V.
5"
CORNER BEAD
EXISTING CONSTRUCTION
CONTINUOUS BACKER ROD
& SEALANT
CONTINUOUS
CAULK JT
FILL EXISTING STUD
CAVITY w/ R-19 BATT
INSULATION
NEW 5/8" GYP BOARD OVER
ALL EXTERIOR WALL
SURFACES WHERE
EXISTING GWB REMOVED
ALUMINUM STOREFRONT
FRAMING
AS SCHEDULED
BLAST-RESISTANT
INSULATING GLAZING
UNIT AS SCHEDULED
NEW SILL BELOW
NEW SILL FLASHING BELOW
2 1/2"
REF PLAN
5/8" GYPSUM WALL
BOARD, BOTH SIDES
METAL STUD BOX
BEAM HEADER
CONTINUOUS
SEALANT (TYPICAL),
BOTH SIDES
CONT. METAL STUD
TRACK, TOP &
BOTTOM, SEE
FLOOR PLAN FOR
WALL TYPE
CONTINUOUS
GYPSUM CORNER
BEAD (TYPICAL)
BOTH SIDES
PREFINISHED
ALUMINUM
STOREFRONT SYSTEM
GLAZING AS
SCHEDULED
SHIM AS REQUIRED
E.Q. E.Q.
REF PLAN
E.Q. E.Q.
5/8" GYPSUM WALL
BOARD, BOTH SIDES
METAL STUD BOX
BEAM HEADER
CONTINUOUS
SEALANT (TYPICAL),
BOTH SIDESCONTINUOUS
GYPSUM CORNER
BEAD (TYPICAL)
BOTH SIDES
PREFINISHED
ALUMINUM
STOREFRONT SYSTEM
GLAZING AS
SCHEDULED
SHIM AS REQUIRED
CONT. METAL STUD
TRACK, TOP &
BOTTOM, SEE
FLOOR PLAN FOR
WALL TYPE
R E
F P
L A
N
DOUBLE STEEL
C-CHANNELS
E .Q
E
.Q
5/8" GYPSUM WALL
BOARD, BOTH SIDES
CONTINUOUS
SEALANT (TYPICAL),
BOTH SIDES
CONTINUOUS
GYPSUM CORNER
BEAD (TYPICAL)
BOTH SIDES
PREFINISHED ALUMINUM
STOREFRONT SYSTEM
GLAZING AS
SCHEDULED
SHIM AS REQUIREDCONTINUOUS TOP &
BOTTOM TRACK
A
6' - 0"
EQ EQ
B5
AE503
E5
AE503
D5
AE503
3' - 6" 7' - 4"
CB
R.O.
F.V. 1' - 9 1/4"
R.O.
F.V.
R .O
F .V
A .F
.F
B1
AE503
D1
AE503
B1
AE503
D1
AE503
F1
AE503
F1
AE503
U.S. Department of Veterans Affairs
CONSULTANTS ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
Drawing Title
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Building Number
Drawing Number
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
Revisions: Date:
VA FORM 08 - 6231
FULLY SPRINKLERED
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
/1
/2
:3
:2
A
M E d ro p b o x
A R
C H
IT
E
C T
U R
E
B
IM
A S
S
IS
T
P R
O J E
C T
S \J
D A
\j d m
.0
N L R
D ia ly s is
C
A
B id
D o c u m e n ts
\5
-1
-1
B
-1
D ia ly s is
A rc h
A d d e n d u m
R
D e ta c h e d .r v t
WINDOW DETAILS CONSTRUCTION
DOCUMENTS
CONSTRUCT INPATIENT DIALYSIS
FOR NLR
EJT HEALTHCARE CENTER, NLR, AR
2020.02.12 JDM AGM
598-18-107
AE503
JDA PROJECT #: D-18-03
A/E
2200 N. RODNEY PARHAM ROAD
SUITE 210
LITTLE ROCK, AR 72212
501-404-4811 jda@JohnsonDanforth.com
JohnsonDanforth & Associates
FIRE PROTECTION
LACEY FIRE PROTECTION
ENGINEERING, LLC
P.O. BOX 723
GREENBRIER AR 72058
MEP ENGINEER
INSIGHT ENGINEERING, PLLC
201 S. CHESTER, SUITE B
LITTLE ROCK, AR 72201
6" = 1'-0" B1
EXTERIOR WINDOW - HEAD DETAIL
6" = 1'-0" D1
EXTERIOR WINDOW - SILL DETAIL
6" = 1'-0" F1
EXTERIOR WINDOW - JAMB DETAIL
3" = 1'-0" B5
INTERIOR WINDOW - HEAD DETAIL
3" = 1'-0" D5
INTERIOR WINDOW - SILL
3" = 1'-0" E5
INTERIOR WINDOW - JAMB DETAIL
SCALE: 6" = 1'-0"
0 1" 2" 4"
SCALE: 3" = 1'-0"
0 2" 4" 8"
1/4" = 1'-0"
INTERIOR WINDOW ELEVATION - A
1/4" = 1'-0"
EXTERIOR WINDOW ELEVATION B & C
FRAME TYPE
GLAZING IL#1GLAZING MG#1
2 AMENDMENT 0003 2023-02-16
| 598-18-107_B-170 Dialysis_Arch - Addendum R20 Detached |
| AE503 - WINDOW DETAILS |
File details come from the government source that posted it. Updated .