A0002 PL102 - FIRST FLOOR PLAN - SANITARY SEWER.pdf
PDF 561 KB Posted
- Solicitation number
- 36C25622R0140
About this file
This document is a solicitation from the Department of Veterans Affairs for construction services to build an approximately 2,600 square foot interior space for a new satellite inpatient dialysis unit at the North Little Rock Veterans Medical Center in Arkansas. The contractor will be responsible for constructing the new interior space in accordance with the attached statement of work, specifications and drawings. The solicitation includes a price breakdown template to be completed by offerors dividing the total proposed price into material, labor, equipment and general requirement costs for each construction division. Proposals are due by January 20, 2023 and the contractor will be responsible for general liability insurance and overhead and profit in addition to the base construction costs. The awarded contract will have a not to exceed price inclusive of all costs.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H
G
J D
11.2
WC-1
WC-1
EW-1
LAV-1
S-3
FD-1
S-4
LAV-1
LAV-1
LAV-1
S-5
FD-1
FD-1
F D
-1
FD-1
FD-1
PJ102
F1
MULTIMULTIMULTIMULTI----USE ROOMUSE ROOMUSE ROOMUSE ROOM
1C-172
STAFF TOILETSTAFF TOILETSTAFF TOILETSTAFF TOILET
1C-171
BARIATRIC BEDBARIATRIC BEDBARIATRIC BEDBARIATRIC BED
STATIONSTATIONSTATIONSTATION
1C-167D
BED COMPATIBLEBED COMPATIBLEBED COMPATIBLEBED COMPATIBLE
STATIONSTATIONSTATIONSTATION
1C-167C
PATIENT TOILETPATIENT TOILETPATIENT TOILETPATIENT TOILET
1C-169
BARIATRIC CHAIRBARIATRIC CHAIRBARIATRIC CHAIRBARIATRIC CHAIR
STATIONSTATIONSTATIONSTATION
1C-167B
BARIATRIC CHAIRBARIATRIC CHAIRBARIATRIC CHAIRBARIATRIC CHAIR
STATIONSTATIONSTATIONSTATION
1C-167A
CORRIDORCORRIDORCORRIDORCORRIDOR
1C-167
EQUIPMENTEQUIPMENTEQUIPMENTEQUIPMENT
PROCESSING,PROCESSING,PROCESSING,PROCESSING,
SOILED RECEIVINGSOILED RECEIVINGSOILED RECEIVINGSOILED RECEIVING
1C-165D
EQUIPMENTEQUIPMENTEQUIPMENTEQUIPMENT
PROCESSING,PROCESSING,PROCESSING,PROCESSING,
CLEAN PREPCLEAN PREPCLEAN PREPCLEAN PREP
1C-165B
EQUIPMENTEQUIPMENTEQUIPMENTEQUIPMENT
PROCESSING,PROCESSING,PROCESSING,PROCESSING,
CLEAN STORAGECLEAN STORAGECLEAN STORAGECLEAN STORAGE
1C-165A
EQUIPMENTEQUIPMENTEQUIPMENTEQUIPMENT
PROCESSING,PROCESSING,PROCESSING,PROCESSING,
REPAIR SHOPREPAIR SHOPREPAIR SHOPREPAIR SHOP
1C-165C
MEDICATION PREPMEDICATION PREPMEDICATION PREPMEDICATION PREP
ROOMROOMROOMROOM
1C-166
NURSE STATIONNURSE STATIONNURSE STATIONNURSE STATION
STORAGE, CLEANSTORAGE, CLEANSTORAGE, CLEANSTORAGE, CLEAN
SUPPLY & CLEANSUPPLY & CLEANSUPPLY & CLEANSUPPLY & CLEAN
LINENLINENLINENLINEN
1C-168A
STORAGE, STERILESTORAGE, STERILESTORAGE, STERILESTORAGE, STERILE
SUPPLYSUPPLYSUPPLYSUPPLY
1C-168
UTILITY ROOM,UTILITY ROOM,UTILITY ROOM,UTILITY ROOM,
SOILEDSOILEDSOILEDSOILED
1C-170
CORRIDORCORRIDORCORRIDORCORRIDOR
STAFF LOUNGESTAFF LOUNGESTAFF LOUNGESTAFF LOUNGE
1C-173
FCO
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
S-2
EW-2 S-1
WF-1
S-1
WF-1 FS-1
WB-1
WB-1
WB-1
WB-1
WB-1
EW-1
FCO
FCO
EW-2
SYMBOLSYMBOLSYMBOLSYMBOL
PPPP----1111
CHECK VALVECHECK VALVECHECK VALVECHECK VALVE
GATE VALVEGATE VALVEGATE VALVEGATE VALVE
BALL VALVEBALL VALVEBALL VALVEBALL VALVE
HOT WATER (HW)HOT WATER (HW)HOT WATER (HW)HOT WATER (HW)
COLD WATER (CW)COLD WATER (CW)COLD WATER (CW)COLD WATER (CW)
NEW EQUIPMENTNEW EQUIPMENTNEW EQUIPMENTNEW EQUIPMENT
DESCRIPTIONDESCRIPTIONDESCRIPTIONDESCRIPTION
PLUMBING LEGEND
PLUMBING FIXTURE DESIGNATIONPLUMBING FIXTURE DESIGNATIONPLUMBING FIXTURE DESIGNATIONPLUMBING FIXTURE DESIGNATION
HOT WATER RETURN (HWR)HOT WATER RETURN (HWR)HOT WATER RETURN (HWR)HOT WATER RETURN (HWR)
SANITARY SEWERSANITARY SEWERSANITARY SEWERSANITARY SEWER
VENTVENTVENTVENT
EXISTING EQUIPMENT TO REMAINEXISTING EQUIPMENT TO REMAINEXISTING EQUIPMENT TO REMAINEXISTING EQUIPMENT TO REMAIN
EXISTING EQUIPMENT TO BE EXISTING EQUIPMENT TO BE EXISTING EQUIPMENT TO BE EXISTING EQUIPMENT TO BE
DEMOLISHEDDEMOLISHEDDEMOLISHEDDEMOLISHED
PIPING TO BE DEMOLISHEDPIPING TO BE DEMOLISHEDPIPING TO BE DEMOLISHEDPIPING TO BE DEMOLISHED
VVVV
SSSSSSSS
FCOFCOFCOFCO FLOOR CLEANOUTFLOOR CLEANOUTFLOOR CLEANOUTFLOOR CLEANOUT
WCOWCOWCOWCO WALL CLEANOUTWALL CLEANOUTWALL CLEANOUTWALL CLEANOUT
FDFDFDFD FLOOR DRAINFLOOR DRAINFLOOR DRAINFLOOR DRAIN
EWEWEWEW EYE WASHEYE WASHEYE WASHEYE WASH
U.S. Department of Veterans Affairs
CONSULTANTS ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
Drawing Title
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Building Number
Drawing Number
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
Revisions: Date:
VA FORM 08 - 6231
FULLY SPRINKLERED
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
KCK CJC
/2
/2
:5
:5
P
M B
IM
/1
-0
C o n s tr u c t In p a ti e n t
D ia ly s is
/1
-0
I n p a ti e n t D ia ly s is
I n s ig h t C e n tr a l M o d e l
R v t
.r v t
FIRST FLOOR PLAN - SANITARY
SEWER
CONSTRUCTION
DOCUMENTS
CONSTRUCT INPATIENT DIALYSIS
FOR NLR
EJT HEALTHCARE CENTER, NLR, AR
2020.02.12
598-18-107
PL102
JDA PROJECT #: D-18-03
A/E
2200 N. RODNEY PARHAM ROAD
SUITE 210
LITTLE ROCK, AR 72212
501-404-4811 jda@JohnsonDanforth.com
JohnsonDanforth & Associates
FIRE PROTECTION
LACEY FIRE PROTECTION
ENGINEERING, LLC
P.O. BOX 723
GREENBRIER AR 72058
MEP ENGINEER
INSIGHT ENGINEERING, PLLC
900 S. SHACKLEFORD, SUITE 300
LITTLE ROCK, AR 72211
FIRST FLOOR SLAB ELEVATION = 303.0'
1/4" = 1'-0"
F4
FIRST FLOOR PLAN - SANITARY SEWER
SANITARY SEWER KEYED NOTES:
1. EXISTING 6" SANITARY LINE IS LOCATED IN CRAWL SPACE
AND EXITS BUILDING IN THE DIRECTION OF PLAN NORTH.
CONNECT NEW SANITARY LINES TO EXISTING. CONNECTION
LOCATION IS ESTIMATED.
N
KEY PLAN
PLAN
NORTH
A
B C
DE
G
M
N
HJ
K L
M
SCALE: 1/4" = 1'-0"
0 2' 4' 8'
N
AN
SKR A
A S
C E R T
IF
IC
AT
EO
FAUTHOR
IZ
AT
IO
N
INSIGHT
ENGINEERING, PLLC
No. 3523
NO. 12022
ARKANSAS
ENGINEER
PROFESSIONAL
REGISTERED
OFETAS T
K
IM
B
ERLY CLA I
R
K O C H
2020.02.122020.02.122020.02.122020.02.12
1 ADDENDUM 2 01-20-23
| Sheets |
| PL102 - FIRST FLOOR PLAN - SANITARY SEWER |
File details come from the government source that posted it. Updated .