36C25622R0014 - ARCH REC DWGS 42(AE-530).pdf
PDF 241 KB Posted
- Solicitation number
- 36C25622R0014
About this file
This document contains construction drawings for ceiling details and a related federal contract opportunity notice. The drawings show framing, bracing, ceiling, wall, and toilet compartment installation details for a laundry and dietetics renovation project at the Biloxi VAMC. The contract opportunity is solicitation number 36C25622R0014 to replace multiple flat roofs at the Biloxi VAMC facility for project number 520-22-102. The Department of Veterans Affairs Veterans Health Administration VISN 16 is listed as the contracting agency. The purpose of the posting is to solicit bids for the roof replacement project. No other details are provided on response dates, award dates, pricing terms, or set asides.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLG AS
SCHEDULED
1/
4"
MAIN TEE
WALL ANGLE
DIAGONAL BRACING
METAL STUD FRAMING -
HANGER WIRE - SECURE
TO STRUCTURE ABOVE
CEILING AS SCHEDULED
ACOUSTICAL CEILING UNITS
METAL STUD FRAMING
5/8" GWB
2"
SEE RCP
VARIES
UNLESS OTHERWISE NOTED
HANGER WIRE SECURE
TO STRUCTURE ABOVE
ATTACHMENT ANGLE
ACOUSTICAL CEILING UNITS
EXPANSION JOINT ASSEMBLY
WALL STUD SUPPORT
1SA WALL - SEE WALL TYPES
EXTRA LAYER OF 5/8" GWB
STEEL STUD
5/8" GWB 6"
CLG AS
SCHEDULED
DIAGONAL BRACING -
ANCHOR TO STRUCTURE
ABOVE
HANGER WIRE - SECURE
TO STRUCTURE ABOVE
METAL STUD FRAMING
5/8" GWB
5/8" GWB
V A
R
IE
S
1"
LINE OF MILLWORK
BOTTOM OF SOFFIT
EL=6' - 4 1/2" AFF @ LOCKERS
EL=7' - 2 1/2" AFF @ UPPER CABINETS
EXTEND GWB TIGHT TO
STR DECK, INSURE
COMPLETE SEAL
FINISH CEILING
5/8" GWB
SUSPENDED BRACKET BY OPERABLE PARTITION MFR
CONTINUOUS CAULK - BOTH SIDES OF TRACK
OPERABLE PARTITION TRACK
SWAY BRACING, SEE
STR DWGS
SOUND ATTENUATION
THREADED HANGER ROD
FINISH FLOOR
ADD WOOD TRIM @ "SIM"
GWB ON METAL STUD FRAMING
W/ ACOUSTICAL BATT
INSULATION - SEE WALL TYPES
B1
EXPANDING PANEL JAMB
B2
BULB SEAL JAMB
B3
AT PERPENDICULAR TO EITHER SEAL
EXTRA METAL STUDS TO SUPPORT
PRESSURE OF PARTITION CLOSURE
A
HEAD
OPERABLE PARTITION PANEL
OPERABLE PARTITION TOP SEAL
OPERABLE PARTITION RETRACTABLE BOTTOM SEAL
OPERABLE PARTITION PANEL
EXPANDING PANEL AT
REARMOST PANEL EDGE
BULB SEAL AT LEADING PANEL EDGE
STL SUPPORT, SEE STR
A1.9
SUSPENDED ACOUSTICAL
WOOD PLANK CEILING
17'-6"
BOTTOM OF COVE
LIGHT FIXTURE AND HOUSING.
SEE ELECTRICAL
WALL AS SCHEDULED
6"
A1.9
1/4" BENT PLATE W/
4" LEGS 1'-0" LONG
1/
4" M
A X
3" M
IN
C
E
IL
IN
G
H E
IG
H
T (A
FF
A S
S C
H E
D U
LE
D
CONTINUOUS L4x4x1/4
5/8" DIAMETER STEEL ROD KICKER TO
BENT PLATE ABOVE - WELD TO VERT ROD
BEVELED WASHER
CONTINUOUS C6x8.2 FULL LENGTH OF
TOILET PARTITION
FASTEN TO CONCRETE
FILLED METAL DECK
STRUCTURE WITH (2)
3/8" HILTI KWIK HUS-EZ
ANCHORS WITH 1 5/8
EMBEDMENT AT 6" O.C.
(IN LOWER FLUTE)
5/8" DIAMETER STEEL
THREADED ROD AT 4'-0" O.C.,
FASTEN TO ANGLE ABOVE
5/8" DIAMETER STEEL
ROD KICKER AT ENDS -
BRACE AT ENDS IF C6
NOT FASTENED TO WALL
HANGER WIRE
L4x4x1/4 FASTENED
TO FRAMING IN
STUD WALL BEYOND
EXTRA STRONG STEEL
PIPE SLEEVE SPACER
GWB CEILING AS SCHEDULED
CLOSURE TO CEILING BY TOILET
COMPARTMENT MANUFACTURER
TOILET COMPARTMENT PILASTER
THREADED RODS WITH NUTS AND
WASHERS PER TOILET
COMPARTMENT MANUFACTURER'S
RECOMMENDATIONS
2" METAL DECK WITH
2" NORMAL WEIGHT
CONCRETE FILL
L4x4x1/4, 1'-0" LONG
AT 4'-0" O.C.
3/16"
3 SIDES
1/
4" M
A X
2' -0
C
E
IL
IN
G
H E
IG
H
T (A
FF
A S
S C
H E
D U
LE
D
HANGER WIRE
GWB CEILING AS SCHEDULED
CLOSURE TO CEILING BY TOILET
COMPARTMENT MANUFACTURER
TOILET COMPARTMENT PILASTER
THREADED RODS WITH NUTS AND
WASHERS PER TOILET
COMPARTMENT MANUFACTURER'S
RECOMMENDATIONS
COLD FORMED METAL FRAMING
AS REQUIRED FOR CEILING HUNG
TOILET COMPARTMENT SUPPORT
COLD FORMED METAL JOIST
FRAMING AS REQUIRED TO
SUPPORT CEILING AND
CEILING MOUNTED ITEMS
3" M
IN
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
8600 Indian Hills Drive
Omaha, NE 68114-4039 USA
Tel 402-391-8111 Fax 402-391-8564
EST. 1915
757 St. Charles Avenue
New Orleans, LA 70130 USA
Tel 504-524-4634 Fax 504-524-5128
JOINT VENTURE
Architect Project No. Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
Revisions Date
CONSULTANTS:
BILOXI, MS
ARCHITECT/ENGINEERS: 520-317S
31, 35
Office of Construction and
Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
/1
/2
:5 :5
P
M
001-10017-021
GMR ALS08/06/12
BILOXI VAMC LAUNDRY / DIETETICS
AE-530
CEILING DETAILS
SCALE: 1 1/2" = 1'-0"2 TYPICAL BULKHEAD DETAIL
SCALE: 1 1/2" = 1'-0"3 EXPANSION JOINT DETAIL - ATC TO WALL
SCALE: 1 1/2" = 1'-0"1 TYPICAL SOFFIT DETAIL @ MILLWORK
SCALE: 1 1/2" = 1'-0"4 OPERABLE PARTITION DETAIL
SCALE: 1 1/2" = 1'-0"5 COVE DETAIL AT MAIN LOBBY
SCALE: 1 1/2" = 1'-0"6 TOILET COMPARTMENT HANGER DETAIL
SCALE: 1 1/2" = 1'-0"7 TOILET COMPARTMENT HANGER DETAIL
RECORD DRAWINGS
File details come from the government source that posted it. Updated .