36C25622R0014 - ARCH REC DWGS 22(AE-301).pdf

PDF 447 KB Posted

Attached to
Z2DZ--Regular Construction Project: 520-22-102 Replace Multiple Flat Roofs, Biloxi
Solicitation number
36C25622R0014
Issued by

About this file

This document contains architectural drawings and related specifications for a federal construction project. The drawings depict building sections for a laundry and dietetics facility at the Biloxi Veterans Affairs Medical Center in Biloxi, Mississippi. The project involves replacing multiple flat roofs and will be awarded through solicitation number 36C25622R0014 by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The solicitation type is listed as regular construction. No further salient details are provided in the architectural drawings or federal contract opportunity beyond the project name and location.

View the file

Other files

File Type Posted
36C25622R0014 A0004 - RFI Register.pdf PDF
36C25622R0014 0004.docx DOCX document
36C25622R0014 - ARCH REC DWGS 18(AE-140).pdf PDF
36C25622R0014 - RFI Register.pdf PDF
36C25622R0014 - ARCH REC DWGS 38(AE-512).pdf PDF
36C254622R0014 - Revised Specifications (31).pdf PDF
36C25622R0014 - ARCH REC DWGS 20(AE-201).pdf PDF
36C25622R0014 - ARCH REC DWGS 36(AE-510).pdf PDF
36C25622R0014 - VAAR Clause 852.219-77 - Certification.docx DOCX document
36C25622R0014 - ARCH REC DWGS 40(AE-514).pdf PDF
36C25622R0014 - ARCH REC DWG BLDG 31 ROOF LAYOUT.pdf PDF
36C25622R0014 - ARCH REC DWGS 42(AE-530).pdf PDF
36C25622R0014 - ARCH REC DWGS 39(AE-513).pdf PDF
36C25622R0014 - ARCH REC DWGS 23(AE-310).pdf PDF
36C25622R0014 - ARCH REC DWGS 21(AE-202).pdf PDF
36C25622R0014 - ARCH REC DWGS 41(AE-515).pdf PDF
36C25622R0014 - ARCH REC DWGS 13(AE-130).pdf PDF
36C25622R0014 0003.docx DOCX document
36C25622R0014 - ARCH REC DWGS 24(AE-311).pdf PDF
36C25622R0014 - ARCH REC DWGS 25(AE-312).pdf PDF
36C25622R0014 - ARCH REC DWGS 37(AE-511).pdf PDF
(2) Site Visit Sign-In Sheets - Proj 520-22-102.pdf PDF
36C25622R0014 0002.docx DOCX document
36C25622R0014 - A0001 RFI Register.pdf PDF
36C25622R0014 0001.docx DOCX document
36C25622R0014 - Drawing 3 (T-105).pdf PDF
36C25622R0014_1.docx DOCX document
36C25622R0014 - Specifications.pdf PDF
36C25622R0014 - Site Visit Map - Biloxi VA.pdf PDF
36C25622R0014 - Drawing 2 (T-104).pdf PDF
36C25622R0014 - Davis Bacon Wage Determination.pdf PDF
36C25622R0014 - Infection Control Constr Permit-IRCA.pdf PDF
36C25622R0014 - Exhibit A Performance Relevancy Survey.docx DOCX document
36C25622R0014 - Exhibit F - Request for Information Form.docx DOCX document
36C25622R0014 - Exhibit E - Surety Form.docx DOCX document
36C25622R0014 - Exhibit C Subcontractor Information and Consent.docx DOCX document
36C25622R0014 - Drawing 1 (Bldg 31).pdf PDF
36C25622R0014 - Exhibit B - Past and Present Performance Questionnaire.docx DOCX document
36C25622R0014 - Exhibit D - Contractor Evaluation Form Construction Safety.docx DOCX document
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEVEL 1

100'-0"

MID ROOF TOS

123'-0"

HIGH ROOF TOS

130'-0"

LOW ROOF TOS

115'-4"

AE.4 D.9 D.5 D.1 C.7 C.6 B.9

AE-310

INSULATED METAL

PANEL WALL

STANDING SEAM METAL ROOF

INSULATED METAL PANEL WALL

CANOPY ROOF

DIETICIAN HAC

FOOD PREP &

PRODUCTION

TRAY ASSEMBLY

TRAY RETHERM

SYSTEM

TRUSS SYSTEM

AABBCCB

AE-301

AE-301

1'-6"

SC-1 FINISH SC-1 FINISH

AE-310

SIM

AE-512

AE-605

12 SIM

REV

AE-310

LEVEL 1

100'-0"

HIGH ROOF TOS

130'-0"

LOW ROOF TOS

115'-4"

CDEFG

AE-310

AE-310

AE-310

SPARE PARTS

MEZZANINE

BACK-UP

STORAGE

CLEAN LINEN

PROCESSING

SOILED CART

HOLDING

SORTING

PLATFORM

INSULATED METAL PANEL WALL

TRUSS SYSTEM

STANDING SEAM METAL ROOF

B

AE-310

AE-301

AE-301

STEEL SUPPORT FRAMING

LEVEL 1

100'-0"

MID ROOF TOS

123'-0"

HIGH ROOF TOS

130'-0"

AE-301

AE-301

LOW ROOF TOS

115'-4"

1514.51413.313.21312111098765421

AE-301

AE-301

MEZZANINE LEVEL

115'-9 1/2"

15.515.20.9 0.95

AE-310

INSULATED METAL PANEL WALL

STANDING SEAM METAL ROOF

CANOPY ROOF INSULATED METAL PANEL WALL

STANDING SEAM METAL ROOF

INSULATED METAL

PANEL WALL

STANDING SEAM METAL ROOF

INSULATED METAL PANEL WALL

RECEIVING

SOILED CART

HOLDING

CLEAN LINEN

PROCESSING MECHANICAL

MAIN ELECTRICAL

SUBSTATION

NON FOOD

STORAGE

FOOD PREP &

PRODUCTION

REFRIGERATED

BLAST CHILLED

STORAGE

AUTOMATED

CART WASH

MECHANICAL

MEZZANINE

SORTING

PLATFORM

TRUSS SYSTEMTRUSS SYSTEM

AE-310

STEEL SUPPORT FRAMING

6.95 7.8

SC-1 FINISH

2' -2

/8

" 3 5/8"

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

8600 Indian Hills Drive

Omaha, NE 68114-4039 USA

Tel 402-391-8111 Fax 402-391-8564

EST. 1915

757 St. Charles Avenue

New Orleans, LA 70130 USA

Tel 504-524-4634 Fax 504-524-5128

JOINT VENTURE

Architect Project No. Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

Revisions Date

CONSULTANTS:

BILOXI, MS

ARCHITECT/ENGINEERS: 520-317S

31, 35

Office of Construction and

Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

/1

/2

:5 :4

P

M

001-10017-021

GMR CRD08/06/12

BILOXI VAMC LAUNDRY / DIETETICS

AE-301

BUILDING SECTIONS

SCALE: 1/8" = 1'-0"3 BUILDING SECTION

SCALE: 1/8" = 1'-0"2 BUILDING SECTION

SCALE: 1/16" = 1'-0"1 BUILDING SECTION

1 RFI 5123 1/20/2014

2 RFI 5148 2/25/2014

RECORD DRAWINGS