This document contains architectural drawings and specifications for project 520-22-102 to replace multiple flat roofs at the Biloxi Veterans Affairs Medical Center. The project involves removing existing built-up roofs and installing new standing seam metal roofs with related sheet metal gutters and accessories. Additional work includes precast concrete walls, insulated metal wall panels, roof access doors, ladders, and supports for solar heating panels and photovoltaic arrays. The drawings depict building elevations, sections, and details to communicate the scope and design of the roof replacement and associated work. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 16 for contract number 36C25622R0014.
View the file
Other files for this federal contract opportunity
Show all 39
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HIGH ROOF TOS
130'-0"
LOW ROOF TOS
115'-4"
EF E.9 E.4
STANDING SEAM METAL ROOF
SHEET METAL GUTTER
PRECAST CONCRETE CAPITAL
AE-310
HIGH ROOF TOS
130'-0"
LOW ROOF TOS
115'-4"
10987
MEZZANINE LEVEL
115'-9 1/2"
STANDING SEAM METAL ROOF
SHEET METAL GUTTER
PRECAST CONCRETE CAPITAL
LOUVER
ROOF ACCESS DOOR
6.9
L2 L1 L2
LEVEL 1
100'-0"
GRADE
99'-6"
LOW ROOF TOS
115'-4"
16 17
STANDING SEAM METAL ROOF
PRECAST CONCRETE CAPITAL PRECAST CONCRETE
FACE
BRICK
PRECAST CONCRETE PRECAST CONCRETE
PREFINISHED GUTTER
1' - 0"
9'-0"
2'-6" 4'-0" 2'-6"
'-6
2' -1
5'
-0
5' -0
4'
-5
AE-451
16.3 16.716.1 16.2 16.8 16.9
2' -0
/4
1'
-1
5/ 8"
LEVEL 1
100'-0"
LOW ROOF TOS
115'-4"
A3 A.1
AE-450
AE-450
AE-451
A2 B3A1.9 B1 B2
LEVEL 1
100'-0"
LOW ROOF TOS
115'-4"
A3 A.1
AE-450
AE-450
AE-451
A2B3 A1.9B1B2
MID ROOF TOS
123'-0"
LOW ROOF TOS
115'-4"
A C D D.1C.7C.6B.9CC C.3
INSULATED METAL WALL PANELS
B
AE-301
AE-301
SOLAR HEATING PANELS
WITH SECONDARY SUPPORTS
BY PANEL MFR
SUPPORTS FOR SOLAR HEATING
PANELS, SEE STR DWGS
AE-310
SCUPPER, CONDUCTOR HEAD
AND DOWNSPOUT
AE-512
AE-312
MID ROOF TOS
123'-0"
AE-301
AE-301
LOW ROOF TOS
115'-4"
14.5 14 13.3 13.2 13 12 1111.312.7
ROOF ACCESS LADDER
INSULATED METAL WALL PANELS
AE-312
MID ROOF TOS
123'-0"
HIGH ROOF TOS
130'-0"
LOW ROOF TOS
115'-4"
C.6 B.9
INSULATED
METAL WALL
PANELS
AE-301
AE-301
ROOF ACCESS LADDER
HIGH ROOF TOS
130'-0"
LOW ROOF TOS
115'-4"
D.1 C.7 B.9
MEZZANINE LEVEL
115'-9 1/2"
ROOF ACCESS DOOR
B
BEJBEJBEJ BEJ
AE-301
AE-301
AE-513
TOP PRECAST 1/2
LENGTH SHOWN
TYPICAL ALL AROUND
HIGH ROOF TOS
130'-0"
C D ED.9D.5D.1C.7C.6B.9B
AE-301
AE-301
C.62B.93B.1 B.5
SUPPORTS FOR
PHOTOVOLTAIC PANELS
L3
HIGH ROOF TOS
130'-0"
9 8 7 6 5 4 2
AE-301
AE-301
7.8
SUPPORTS FOR
PHOTOVOLTAIC PANELS
HIGH ROOF TOS
130'-0"
CDE B
AE-301
AE-301
SUPPORTS FOR
PHOTOVOLTAIC PANELS
LOW ROOF TOS
115'-4"
AE-451
16.216.8
AE-311
CJ CJ
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
8600 Indian Hills Drive
Omaha, NE 68114-4039 USA
Tel 402-391-8111 Fax 402-391-8564
EST. 1915
757 St. Charles Avenue
New Orleans, LA 70130 USA
Tel 504-524-4634 Fax 504-524-5128
JOINT VENTURE
Architect Project No. Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
Revisions Date
CONSULTANTS:
BILOXI, MS
ARCHITECT/ENGINEERS: 520-317S
31, 35
Office of Construction and
Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
/1
/2
:5 :4
P
M
001-10017-021
GMR RAS08/06/12
BILOXI VAMC LAUNDRY / DIETETICS
AE-202
BUILDING ELEVATIONS
SCALE: 1/8" = 1'-0"4 PARTIAL EAST ELEVATION (BEHIND MAIN ENTRY)
SCALE: 1/8" = 1'-0"5 PARTIAL SOUTH ELEVATION (BEHIND MAIN ENTRY)
SCALE: 1/8" = 1'-0"1 SOUTHEAST ELEVATION (MAIN ENTRY)
SCALE: 1/8" = 1'-0"2 PARTIAL SOUTHWEST ELEVATION (MAIN ENTRY)
SCALE: 1/8" = 1'-0"3 PARTIAL NORTHEAST ELEVATION (MAIN ENTRY)
SCALE: 1/8" = 1'-0"7 PARTIAL WEST ELEVATION (CLERESTORY ABOVE KITCHEN)
SCALE: 1/8" = 1'-0"8 PARTIAL NORTH ELEVATION (CLERESTORY ABOVE KITCHEN)
SCALE: 1/8" = 1'-0"9
PARTIAL EAST ELEVATION
(CLERESTORY ABOVE KITCHEN)
SCALE: 1/8" = 1'-0"6 PARTIAL EAST ELEVATION
SCALE: 1/16" = 1'-0"10 PARTIAL EAST ELEVATION (HIGH ROOF)
SCALE: 1/16" = 1'-0"11 PARTIAL NORTH ELEVATION (HIGH ROOF)
SCALE: 1/16" = 1'-0"12 PARTIAL WEST ELEVATION (HIGH ROOF)
SCALE: 1/8" = 1'-0"3A ELEVATION - BACKSIDE
1 RFI 5028 7/8/2013
2 RFI 5172 & 5175 5/6/2014
RECORD DRAWINGS