36C25621R0148 Drawings .pdf
PDF 25 MB Posted
- Solicitation number
- 36C25621R0148
About this file
This solicitation is for Project #502-17-300 to convert a laundry facility to a distribution and storage facility for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The solicitation seeks firms to convert an existing laundry building into storage space and offices through renovations such as installing walls, doors, electrical work, and HVAC systems. Responses are due by the date listed on FedBizOpps, with award expected within 90 days thereafter. The contractor will be responsible for all necessary construction work to complete the facility conversion per the drawings provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25621R0148 0003.docx | DOCX document | |
| RFI Register 502-17-300 23 July 2021.docx | DOCX document | |
| Equipment List.docx | DOCX document | |
| 36C25621R0148 0002.docx | DOCX document | |
| Pre-Award RFI Register 19 May 2021 Final.pdf | ||
| 36C25621R0148 0001.docx | DOCX document | |
| Sign in Sheet.pdf | ||
| 36C25621R0148 Specifications.pdf | ||
| 36C25621R0148 EXHIBIT F.docx | DOCX document | |
| 36C25621R0148 EXHIBIT E.docx | DOCX document | |
| 36C25621R0148 ICRA.pdf | ||
| 36C25621R0148 JA.pdf | ||
| 36C25621R0148 EFT Form.pdf | ||
| 36C25621R0148 EXHIBIT C.docx | DOCX document | |
| 36C25621R0148 Vendor Request Form.xlsx | XLSX spreadsheet | |
| 36C25621R0148 SOW .docx | DOCX document | |
| 36C25621R0148 EXHIBIT G.docx | DOCX document | |
| 36C25621R0148 EXHIBIT A.docx | DOCX document | |
| 36C25621R0148 Solicitation.docx | DOCX document | |
| 36C25621R0148 EXHIBIT B.docx | DOCX document | |
| 36C25621R0148 EXHIBIT D.docx | DOCX document | |
| 36C25621R0148 WD.txt | TXT text file | |
| 36C25621R0148 Pre-Sol.docx | DOCX document |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING LIST
1i
0 GRID / COLUMN LINE DESIGNATOR
EQUIPMENT NUMBER
DOOR NUMBER
Ga5xFB1
WALL TYPE
WINDOW TYPE
ROOM NAME
101 ROOM NAME / NUMBER
REVISION TAG
PLAN NORTH
NORTH ARROW WITH TRUE
NORTH INDICATION
EGRESS ROUTE ID AND
SECTION LENGTH
ROOM
ROOM OCCUPANCY
150 SF
EGRESS : EGRESS ID
Egress Length
ROOM OCCUPANCY & AREA
ELEVATION NUMBER
SECTION
INTERIOR ELEVATION
ENLARGEMENT,
DETAIL
SPOT ELEVATION
Name Elevation FLOOR LEVEL &
NAME
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
SHEET KEYNOTE
A101
SIM
EXTERIOR ELEVATION
A-101
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
INDEX OF DRAWINGS
202-A101
DISCIPLINE:
G - GENERAL INFORMATION
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T - TELECOM
Q - FOOD SERVICE
SHEET TYPE
DESIGNATOR
VICINITY MAP
PROJECT TEAMBUILDING SUMMARY
PROJECT INFORMATION
THE SCOPE OF THE PROJECT IS TO PROVIDE ALL CONSTRUCTION NECESSARY TO ACCOMPLISH THE CONVERSION OF THE
EXISTING LAUNDRY TO A LAUNDRY DISTRIBUTION STORAGE FACILITY.
ANNOTATION DRAWING SYMBOLSGENERAL NOTES
PROJECT NAME: CONVERT ALEXANDRIA LAUNDRY TO DISTRIBUTION STORAGE
PROJECT NUMBER: 502-17-300
PROJECT LOCATION: 2495 SHREVEPORT HIGHWAY PINEVILLE, LA 71360
PROJECT PURPOSE/USE: THE CONVERSION OF THE EXISTING LAUNDRY TO A DISTRIBUTION STORAGE.
BUILDING AREA:
FIRST FLOOR: 12,469 GSF
BASEMENT (RENOVATION AREA): 1,176 GSF
TOTAL: 13,645 GSF
BUILDING NUMBER
1. THESE DRAWINGS SHALL BE USED ONLY FOR THIS SPECIFIC PROJECT/SITE
LOCATION. THESE DRAWINGS ARE A COMPOSITE SET OF CONTRACT DOCUMENTS
AND SHALL NOT BE SEPARATED FOR DISTRIBUTION. THE GC SHALL REVIEW ALL
DRAWINGS AND PROVIDE/DISTRIBUTE THE ENTIRE SET TO EACH
SUBCONTRACTOR.
2. THE GC SHALL VISIT THE SITE TO INSPECT EXISTING CONDITIONS AND VERIFY
WORK BEING PERFORMED BEFORE SUBMITTING COST QUOTATIONS FOR WORK.
3. NOTIFY THE ARCHITECT PROMPTLY OF ANY ERRORS, OMISSIONS,
INCONSISTENCIES, DISCREPANCIES AND CONFLICTS WITHIN THE CONTRACT
DOCUMENTS AND ITS ASSOCIATED FIELD/PROJECT CONDITIONS SO THAT A
RESOLUTION CAN BE PROVIDED PRIOR TO CONTINUING WITH WORK.
4. DO NOT SCALE THE DRAWINGS. REQUEST ANY MISSING DIMENSIONS FROM THE
ARCHITECT.
5. ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH GOVERNING
FEDERAL, STATE AND LOCAL BUILDING CODE REQUIREMENTS, SHALL BE
EXECUTED IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARDS, AND SHALL
CONFORM TO SPECIFIC REGULATIONS AS MANDATED BY THE OWNER, THE
ARCHITECT, AND THE AUTHORITIES HAVING JURISDICTION. THE GENERAL
CONTRACTOR IS RESPONSIBLE FOR ANY FEES ASSOCIATED WITH PROCURING
SUCH PERMITS AND CERTIFICATES AND SHALL FURNISH COPIES OF PERMITS,
INSPECTIONS, AND CERTIFICATES TO THE OWNER.
6. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK TO MINIMIZE
DISRUPTION OF OF ANY EXISTING TENANTS OR BUILDING OPERATIONS. THE
GENERAL CONTRACTOR SHALL TAKE ADEQUATE PRECAUTIONS TO PROTECT
BUILDING OCCUPANTS, MATERIALS, AND EXISTING CONSTRUCTION THROUGHOUT
ALL PHASES OF CONSTRUCTION. DAMAGE TO EXISTING-TO-REMAIN
CONSTRUCTION OR EQUIPMENT SHALL BE RESTORED TO ORIGINAL CONDITION AT
THE CONTRACTOR'S EXPENSE.
7. THE GENERAL CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE
JOB SITE ON A DAILY BASIS.
8. ANY REQUESTS FOR SUBSTITUTIONS OF ANY SPECIFIED ITEM ARE TO BE
SUBMITTED TO THE ARCHITECT IN WRITING AND WILL BE CONSIDERED ONLY IF THE
ALTERNATE PROPOSED IS PROVEN TO BE ADVANTAGEOUS TO THE OWNER WITH
RESPECT TO DELIVERY DATE, QUALITY, OR COST.
9. THE MEANS AND METHODS OF CONSTRUCTION, AND TEMPORARY STRUCTURES
AND FACILITIES, ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE
ARCHITECT DOES NOT ASSUME ANY RESPONSIBILITY FOR THE CONTRACTOR'S
MEANS AND METHODS OR FOR TEMPORARY STRUCTURES.
10. DEMOLITION OF EXISTING STRUCTURES IS THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR. THE CONTRACTOR SHALL EMPLOY ENGINEERING EXPERTISE AS
NEEDED TO ASSIST IN DEMOLITION.
11. JOB SITE SAFETY AND SECURITY ARE THE SOLE RESPONSIBILITY OF THE GENERAL
CONTRACTOR. THE GENERAL CONTRACTOR SHALL CONSULT WITH LOCAL FIRE
AUTHORITIES TO ASCERTAIN REQUIREMENTS FOR FIRE SUPPRESSION AND
SAFETY DURING CONSTRUCTION. THE GENERAL CONTRACTOR IS SOLELY
RESPONSIBLE FOR MEETING OSHA REGULATIONS DURING CONSTRUCTION.
12. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR STORAGE AND
PROTECTION OF BUILDING MATERIALS, AND INSTALLED CONSTRUCTION, FROM
INCLEMENT WEATHER, THEFT, AND OTHER HAZARDS.
A101
A101
SCOPE OF WORK SUMMARY:
SHEET NUMBER
WITHIN SERIES
ALTERNATE INDEX
DEDUCT ALTERNATE 1 SEE SHEET MD-100
0' 1'
6" 3"
1'
Gr ap hi c S ca le
: 1 /2"
1'-
0"
0' 4"
8" 1'
2'
Gr ap hi c S ca le
: 3 /32
1'
-0
0'
8' Gr ap hi c S ca le : 1
/16
1' -0
0' 8'
4' Gr ap hi c S ca le
: 1 /8"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 1 /4"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 3 /8"
1'-
0"
0' 2'
4' 1' Gr ap hi c S ca le : 1
/2"
1'- 0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 3 /4"
1'-
0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 1
1' -0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:Consultant:
EE
ES
S OF
M
R C
D
T
T T
IIN
U A
AA
V
RAP
M
N
T
T OF
E E
D
RS
I
FA
A
NT
SR
F
AEE
10/30/2020
BI
M
VI
SN
- A le xa nd ria
L au nd ry
/A le xa nd ria L au nd ry .rv t
/2 /2
:2
6:
P M
SHEET INDEX & GENERAL INFORMATION
GC TLZ
Sprinklered
ALEXANDRIA, LA
10/30/2020
ALEXANDRIA,
LA
G-00116-
502-17-300
PROJECT NUMBER - 502-17-300
RCC CONTRACT NUMBER - 36C25618C0170
RCC PURCHASE ORDER NUMBER - 502-C84108
CONVERT ALEXANDRIA
LAUNDRY TO DISTRIBUTION
STORAGE
CONSTRUCTION DOCUMENTS CONVERT ALEXANDRIA
LAUNDRY TO DISTRIBUTION
STORAGE
CONSTRUCTION DOCUMENTS
10/30/2020
2495 SHREVEPORT HIGHWAY
PINEVILLE, LA 71360
ARCHITECT:
Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093
Rebecca Olson rebecca.olson@romanykconsulting.com
855.424.3838 ext.302
MECHANICAL/ELECTRICAL/
PLUMBING/FIRE ENGINEER:
Schwab-Alexlaund 315 Arden Avenue, Suite 26, Glendale, CA 91203
Varinder Bajaj-Project Manager MEP/Fire Vbajaj@schwabeng.com
Saeid Hashemi-Sr. Mechanical Engineer shashemi@schwabeng.com
OWNER:
Network Contracting Office 16 Construction Team A Alexandria VA Health Care System 2495 Shreveport Hwy, 71N Pineville, LA 71360
JB Herbst-Contracting Specialist 318-466-2236
318-483-5063 (FAX)
SHEET # SHEET TITLE
MECHANICAL
M-001 MECHANICAL FRONT SHEET
M-100 MECHANICAL SCHEDULES
M-101 MECHANICAL SCHEDULES
M-102 MECHANICAL SCHEDULES
M-200 MECHANICAL DETAILS
M-201 MECHANICAL DETAILS
M-202 MECHANICAL DETAILS
M-203 MECHANICAL DETAILS
M-204 MECHANICAL AHU SECTION DETAILS
M-300 MECHANICAL CALCULATIONS
MD-100 MECHANICAL BASEMENT DEMOLITION PLAN
MD-101 MECHANICAL FIRST FLOOR DEMOLITION PLAN
MD-102 MECHANICAL ROOF DEMOLITION PLAN
MH-102 MECHANICAL ROOF PLAN
MH-101 MECHANICAL FIRST FLOOR PLAN
MH-200 MECHANICAL FIRST FLOOR ZONING PLAN
MI-100 MECHANICAL CONTROLS
MI-101 MECHANICAL CONTROLS
MP-100 MECHANICAL BASEMENT PIPING PLAN
MP-101 MECHANICAL FIRST FLOOR PIPING PLAN
MPD-101 MECHANICAL FIRST FLOOR DEMOLITION PIPING PLAN
ELECTRICAL
E-001 ELECTRICAL FRONT SHEET
E-002 ELECTRICAL SYMBOLS AND LEGENDS
E-003 SINGLE LINE DIAGRAM
E-004 PANEL SCHEDULE
E-100 BASEMENT NEW PLAN
ED-100 BASEMENT DEMO POWER / FIRE ALARM PLAN
ED-101 LIGHTING DEMOLITION PLAN
ED-102 POWER DEMOLITION PLAN
ED-103 LOW VOLTAGE SIGNAL DEMOLITION PLAN
ED-200 DEMOLITION ROOF PLAN
EL-101 NEW FLOOR LIGHTING PLAN
EP-102 NEW FLOOR POWER PLAN
EP-103 NEW FLOOR POWER PLAN TERMINAL UNITS
ET-103 NEW FLOOR POWER SIGNAL
EY-104 NEW FLOOR AUXILIARY / FIRE PLAN
EP-200 NEW ROOF PLAN
E-300 ELECTRICAL DETAILS
Grand total: 87
SHEET # SHEET TITLE
GENERAL
G-001 SHEET INDEX & GENERAL INFORMATION
G-002 BUILDING CODE
G-101 LIFE SAFETY PLAN
G-102 SITE PLAN
STRUCTURAL
S-001 GENERAL NOTES AND TYPICAL DETAILS
S-201 PLAN AND DETAILS
S-202 ROOF FRAMING PLAN AND DETAILS
ARCHITECTURAL
AD-100 BASEMENT DEMOLITION PLAN
AD-101 FIRST FLOOR DEMOLITION PLAN
AD-102 ROOF DEMOLITION PLAN
A-100 BASEMENT PLAN
A-101 OVERALL FLOOR PLAN
A-102 ENLARGED FLOOR PLAN - AREA 1
A-103 ENLARGED FLOOR PLAN - AREA 2
A-104 ENLARGED FLOOR PLAN - AREA 3
A-105 ROOF PLAN
A-120 FIRST FLOOR REFLECTED CEILING PLAN
A-201 EXTERIOR ELEVATIONS
A-202 BUILDING SECTIONS
A-203 BUILDING SECTIONS
A-300 ENLARGED TOILET AND SHOWER PLANS AND ELEVATIONS
A-301 ENLARGED LAUNDRY ROOM PLAN
A-402 ACCESSIBLE DETAILS
A-403 ACCESSIBLE DETAILS
A-404 ACCESSIBLE DETAILS
A-405 MILLWORK ELEVATIONS
A-407 ENLARGED RAMP AND DOCK PLAN
A-406 MILLWORK SECTIONS
A-408 STAIR & RAMP DETAILS
A-502 WALL TYPES
A-504 METAL STUD DETAILS
A-505 CEILING DETAILS SUSPENDED GYPSUM
A-601 DOOR SCHEDULES
A-602 ROOM FINISH PLANS AND SCHEDULES
FIRE
FPD-101 FIRE PROTECTION DEMOLITION PLAN
FP-001 FIRE PROTECTION GENERAL NOTES AND DETAILS
FP-101 FIRE PROTECTION NEW PLAN
PLUMBING
P-001 PLUMBING FRONT SHEET
P-002 PLUMBING SCHEDULES
P-500 PLUMBING DETAILS
PD-101 PLUMBING DEMOLITION CW AND HW FLOOR PLAN
PD-102 PLUMBING DEMOLITION WASTE AND VENT FLOOR PLAN
PD-103 PLUMBING DEMOLITION BASEMENT PLAN
PD-104 PLUMBING DEMOLITION PLUMBING ROOF PLAN
PP-101 PLUMBING NEW COLD AND HOT WATER FLOOR PLAN
PP-102 PLUMBING NEW WASTE AND VENT FLOOR PLAN
PP-103 PLUMBING NEW PLUMBING ROOF PLAN
PP-104 PLUMBING COLD AND HOT WATER RISER DIAGRAMS
PP-105 PLUMBING WASTE AND VENT RISER DIAGRAMS
Revisions: Date:
Revision 1 1/8/2020
300 GROSS
7 NET
5 NET
15 NET
BUSINESS AREAS 100 GROSS
EXERCISE ROOMS 50 GROSS
INDUSTRIAL AREAS 100 GROSS
KITCHENS, COMMERCIAL 200 GROSS
a
20 NET
50 NET
500 GROSS
a
200e 250b
NOT PERMITTED 250b
B 200 300c
300 400c
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
75d
100d
150d
175d
200c
IBC CHAPTER 3 - OCCUPANCY CLASSIFICATION:
302 CLASSIFICATION
303.1 ASSEMBLY GROUP
304.1 BUSINESS GROUP B
306.2 FACTORY INDUSTRIAL F-1 MODERATE-HAZARD OCCUPANCY
306.3 FACTORY INDUSTRIAL F-2 LOW-HAZARD OCCUPANCY
311.2 MODERATE-HAZARD STORAGE, GROUP S-1
311.3 LOW-HAZARD STORAGE, GROUP S-2
312 UTILITY AND MISCELLANEOUS GROUP U
IBC CHAPTER 6 - TYPES OF CONSTRUCTION:
Type IA Type IB Type IIA Type IIB Type IIIA Type IIIB Type IV Type VA
Type VB
TABLE 1004.5
MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
ACCESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
SEE SECTION 1004.6
FUNCTION OF SPACE OCCUPANT LOAD FACTOR
ASSEMBLY WITH FIXED SEATS
ASSEMBLY WITHOUT FIXED SEATS
CONCENTRATED (CHAIRS ONLY - NOT FIXED)
STANDING SPACE
UNCONCENTRATED (TABLES AND CHAIRS)
EDUCATIONAL
CLASSROOM AREA
SHOPS AND OTHER VOCATIONAL ROOM AREAS
WAREHOUSES
BUILDING CODE 2018
IBC CHAPTER 5 - GENERAL BUILDING HEIGHTS AND AREAS:
TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREAS
A. SEE THE FOLLOWING SECTIONS FOR GENERAL EXCEPTIONS TO TABLE 503
SECTION 507 UNLIMITED AREA BUILDINGS
507.1 GENERAL. THE AREA OF BUILDINGS OF THE OCCUPANCIES AND CONFIGURATIONS SPECIFIED IN
SECTIONS 507.1 THROUGH 507.12 SHALL NOT BE LIMITED.
507.5 TWO STORY. THE AREA OF A GROUP B, F, M OR S BUILDING NO MORE THAN TWO STORIES ABOVE GRADE PLANE SHALL NOT BE LIMITED WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, AND IS SURROUNDED AND
ADJOINED BY PUBLIC WAYS OR YARDS NOT LESS THAN 60 FEET (18 288 MM) IN WIDTH.
508.3 NONSEPARATED OCCUPANCIES. BUILDINGS OR PORTIONS OF BUILDINGS THAT
COMPLY WITH THE PROVISIONS OF THIS SECTION SHALL BE CONSIDERED AS
NONSEPARATED OCCUPANCIES.
508.3.1 OCCUPANCY CLASSIFICATION. NONSEPARATED OCCUPANCIES SHALL BE
INDIVIDUALLY CLASSIFIED IN ACCORDANCE WITH SECTION 302.1. THE
REQUIREMENTS OF THIS CODE SHALL APPLY TO EACH PORTION OF THE BUILDING
BASED ON THE OCCUPANCY CLASSIFICATION OF THE SPACE. IN ADDITION, THE MOST
RESTRICTIVE PROVISION OF CHAPTER 9 WHICH APPLY TO THE NONSEPARATED
OCCUPANCIES SHALL APPLY TO THE TOTAL NONSEPARATED OCCUPANCY AREA.
WHERE NONSEPARATED OCCUPANCIES OCCUR IN A HIGH-RISE BUILDING, THE MOST
RESTRICTIVE REQUIREMENTS OF SECTION 403 WHICH APPLY TO THE
NONSEPARATED OCCUPANCIES SHALL APPLY THROUGHOUT THE HIGH-RISE
BUILDING.
508.3.3 SEPARATION. NO SEPARATION IS REQUIRED BETWEEN NONSEPARATED
OCCUPANCIES.
SECTION 1009 ACCESSIBLE MEANS OF EGRESS
1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL
COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN
ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED
BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF
THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS.
1009.7 EXTERIOR AREAS FOR ASSISTED RESCUE. EXTERIOR AREA FOR ASSISTED RESCUE SHALL
BE ACCESSED BY AN ACCESSIBLE ROUTE FROM THE AREA SERVED.
WHERE THE EXIT DISCHARGE DOES NOT INCLUDE AN ACCESSIBLE ROUTE FROM AN EXIT
LOCATED ON THE LEVEL TO THE LEVEL OF EXIT DISCHARGE TO A PUBLIC WAY, AN EXTERIOR
AREA OF ASSISTED RESCUE SHALL BE PROVIDED ON THE EXTERIOR LANDING IN ACCORDANCE
WITH SECTIONS 1009.7.1 THROUGH 1009.7.4.
1009.7.1 SIZE. EACH EXTERIOR AREA FOR ASSISTED RESCUE SHALL BE SIZED TO
ACCOMMODATE WHEELCHAIR SPACES IN ACCORDANCE WITH SECTION 1009.6.3
1009.7.4 SEPARATION. EXTERIOR WALLS SEPARATING THE EXTERIOR AREA OF
ASSISTED RESCUE FROM THE INTERIOR OF THE BUILDING SHALL HAVE A MINIMUM
FIRE-RESISTANCE RATING OF 1 HOUR, RATED FOR EXPOSURE TO FIRE FROM THE
INSIDE. THE FIRE-RESISTANCE-RATED EXTERIOR WALL CONSTRUCTION SHALL
EXTEND HORIZONTALLY NOT LESS THAN 10 FEET (93048MM) BEYOND THE
LANDING ON EITHER SIDE OF THE LANDING OR EQUIVALENT FIRE-RESISTANCE-
RATED CONSTRUCTION IS PERMITTED TO EXTEND OUT PERPENDICULAR TO THE
EXTERIOR WALL NOT LESS THAN 4 FEET (1219MM) MINIMUM ON THE SIDE OF THE
LANDING. THE FIRE-RESISTANCE-RATED CONSTRUCTION SHALL EXTEND
VERTICALLY FROM THE GROUND TO A POINT NOT LESS THAN 10 FEET (3048 MM)
ABOVE THE FLOOR LEVEL OF THE AREA FOR ASSISTED RESCUE OR TO THE ROOF
LINE, WHICHEVER IS LOWER. OPENINGS WITHIN SUCH FIRE-RESISTANCE-RATED
EXTERIOR WALL SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 716.
EXCEPTION: THE FIRE-RESISTANCE RATING AND OPENING PROTECTIVES
ARE NOT REQUIRED IN THE EXTERIOR WALL WHERE THE BUILDING IS EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALL IN ACCORDANCE
WITH SECTION 903.3.1.1 OR 903.3.1.2.
1009.7.5 OPENNESS. THE EXTERIOR AREA FOR ASSISTED RESCUE SHALL BE OPEN
TO THE OUTSIDE AIR. THE SIDES OTHER THAN THE SIDE SEPARATION WALLS
SHALL BE AT LEAST 50 PERCENT OPEN, AND THE OPEN AREA SHALL BE
DISTRIBUTED SO AS TO MINIMIZE THE ACCUMULATION OF SMOKE OR TOXIC
GASES.
1009.7.6 STAIRWAY. STAIRWAYS THAT ARE PART OF THE MEANS OF EGRESS FOR
THE EXTERIOR AREA FOR ASSISTED RESCUE SHALL PROVIDE A CLEAR WIDTH OF
48 INCHES (1219 MM)BETWEEN HAND-RAILS.
EXCEPTION: THE CLEAR WIDTH OF 48 INCHES (1219 MM) BETWEEN HAND-
RAILS IS NOT REQUIRED AT STAIRWAYS SERVING BUILDINGS EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN
ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS:
SECTION 1019.3 ALLOWS FOR OPEN COMMUNICATING STAIR(S) BETWEEN
BOTH FLOORS.***
1020.4 DEAD ENDS. WHERE MORE THAN ONE EXIT OR EXIT ACCESS
DOORWAY IS REQUIRED, THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT
DEAD-END CORRIDORS DO NOT EXCEED 20 FEET (6096 MM) IN LENGTH.
EXCEPTIONS:
2. IN OCCUPANCIES IN GROUPS B, E, F, I-1, M, R-1, R-2, R-4, S AND U,
WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC
SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, THE LENGTH
OF THE DEAD-END CORRIDORS SHALL NOT EXCEED 50 FEET (15 240 MM).
SECTION 1101 GENERAL
1101.1 SCOPE. THE PROVISIONS OF THIS CHAPTER SHALL CONTROL THE DESIGN AND CONSTRUCTION
OF FACILITIES FOR ACCESSIBILITY FOR INDIVIDUALS WITH DISABILITIES.
1102.1 DESIGN. BUILDINGS AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE
ACCESSIBLE IN ACCORDANCE WITH THIS CODE AND ICC A117.1.
1103.2.9 EQUIPMENT SPACES. SPACES FREQUENTED ONLY BY SERVICE PERSONNEL FOR
MAINTENANCE, REPAIR OR OCCASIONAL MONITORING OF EQUIPMENT ARE NOT REQUIRED TO COMPLY
WITH THIS CHAPTER.
1109.12.1 DRESSING, FITTING AND LOCKER ROOMS. WHERE DRESSING ROOMS, FITTING ROOMS OR LOCKER ROOMS ARE PROVIDED, AT LEAST 5 PERCENT, BUT NOT LESS THAN ONE, OF EACH TYPE OF
USE IN EACH CLUSTER PROVIDED SHALL BE ACCESSIBLE.
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE
OCCUPANCY WITHOUT SPRINKLER
SYSTEM
(FEET)
WITH SPRINKLER
SYSTEM
(FEET)
A, E, F-1, M, R, S-1 I-1
F-2, S-2, U H-1 H-2 H-3 H-4 H-5
I-2, I-3
ALL CODES SHALL BE THE LATEST PUBLISHED VERSION
BUILDING CODE: 2018 ICC INTERNATIONAL BUILDING CODE ® (IBC)
NFPA 101 LIFE SAFETY CODE
NFPA NATIONAL FIRE CODES WITH EXCEPTION OF NFPA 5000 AND NFPA 900
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS, VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE
PLUMBING CODE: INTERNATIONAL PLUMBING CODE
ELECTRICAL CODE: NATIONAL ELECTRICAL CODE
VA PHYSICAL SECURITY DESIGN MANUAL (PSDM) - JANUARY 2015
**VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC
REQUIREMENTS ARE DIFFERENT).
IBC CHAPTER 10: MEANS OF EGRESS
IBC CHAPTER 11: ACCESSIBILITY
NFPA 101:
SECTIONS 8.6.6 AND 43.10.4.7.1 ALLOW FOR COMMUNICATING STAIR(S) TO BE NON-RATED
AND OPEN TO BOTH FLOORS
STAIRWAYS
(INCHES PER
OCCUPANT)
0.2 a
1005 MEANS OF EGRESS SIZING ILLUSTRATED
OCCUPANCY
WITH SPRINKLER SYSTEM
OCCUPANCIES OTHER THAN H,
AND I-2
OTHER EGRESS
COMPONENTS
(INCHES PER OCCUPANT)
0.15
CONCENTRATED BUSINESS USE AREA SEE SECTION 1004.6
75 75a
Not Permitted
Not Permitted
TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
MAXIMUM OCCUPANT
LOAD OF SPACE
WITHOUT SPRINKLER
SYSTEM
(feet)
WITH
SPRINKLER
SYSTEM
(feet)
Occupant Load
OL≤30 OL>30
I-3
OCCUPANCY
H-4, H-5 I-1, I-2d, I-4
H-1, H-2, H-3
Ac, E, M B F
R-1 R-2 R-3e
R-4e
Sf
U
Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted
Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted
100a
100a
25b
75b 75a
100a
75a
125a
125a, g
125a, g
100a
75a
1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS
TRAVEL DISTANCE.
TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED
WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON PATH OF EGRESS TRAVEL
DISTANCE EXCEEDS THE VALUE LISTED IN TABLE 1006.2.1. THE CUMULATIVE
OCCUPANT LOAD FROM ADJACENT ROOMS, AREAS OR SPACES SHALL BE
DETERMINED IN ACCORDANCE WITH SECTION 1004.2.
1.THE NUMBER OF EXITS FROM FOYERS, LOBBIES, VESTIBULES OR SIMILAR
SPACES NEED NOT BE BASED ON CUMULATIVE OCCUPANT LOADS FOR AREAS
DISCHARGING THROUGH SUCH SPACES, BUT THE CAPACITY OF THE EXITS FROM
SUCH SPACES SHALL BE BASED ON APPLICABLE CUMULATIVE OCCUPANT LOADS.
I-4 150 200c
200c
1006.3.2 EGRESS BASED ON OCCUPANT LOAD. EACH STORY AND OCCUPIED
ROOF SHALL HAVE THE MINIMUM NUMBER OF SEPARATED AND DISTINCT
EXITS, OR ACCESS TO EXITS, AS SPECIFIED IN TABLE 1006.3.2. A SINGLE EXIT
OR ACCESS TO A SINGLE EXIT SHALL BE PERMITTED IN ACCORDANCE WITH
SECTION 1006.3.3 THE REQUIRED NUMBER OF EXITS, OR EXIT ACCESS
STAIRWAYS OR RAMPS PROVIDING ACCESS TO EXITS, FROM ANY STORY OR
OCCUPIED ROOF SHALL BE MAINTAINED UNTIL ARRIVAL AT THE EXIT
DISCHARGE OR A PUBLIC WAY.
TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
MINIMUM NUMBER OF EXITS OR
ACCESS TO EXITS FROM STORY
OCCUPANT LOAD
PER STORY
1-500
501-1,000
MORE THAN 1,000
BUILDING
A. BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2.
SEE SECTION 903 FOR OCCUPANCIES WHERE AUTOMATIC SPRINKLER SYSTEMS ARE PERMITTED IN ACCORDANCE WITH SECTION 903.3.1.2.
F. THE LENGTH OF COMMON PATH OF EGRESS TRAVEL DISTANCE IN A GROUP S-2 OPEN PARKING GARAGE SHALL BE NOT MORE THAN 100
FEET.
C. BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1.
BUILDING
BUILDING
BUILDING
BUILDING
BUILDING
FIRST FLOOR = 7 EXITS
BASEMENT = 2 EXITS
/EXIT ACCESS
BUILDING
FIRST FLOOR
OCCUPANT LOAD: 124
BASEMENT
OCCUPANT LOAD: 11
TOTAL OCCUPANTS: 135
REFERENCE ARCHITECTURAL BARRIERS ACT (ABA)
EXTERIOR WALLS SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLES
601 AND 602 AND THIS SECTION.
3 A,B
SECTION 601
GENERAL
TABLE 601
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
BUILDING ELEMENT TYPE I
PRIMARY STRUCTURAL FRAME f (See Section 202)
A B
2 A,B
TYPE II
A B A B
TYPE III
HT
TYPE IV TYPE V
A B
BEARING WALLS
EXTERIOR e,f
INTERIOR
NONBEARING WALLS AND PARTITIONS
EXTERIOR
NONBEARING WALLS AND PARTITIONS
INTERIORd
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY
MEMBERS (See Section 202)
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY
MEMBERS (See Section 202)
3A 2A
2 1 0 2 2 2 1 0
1 B 0 1 B 0 HT 1 B 0
1 01 0 1 0 1/HT
SEE TABLE 602
0 0 0 0 0 0 0 0
SEE SECTION
2304.11.2
HT
HT
2 2 1 0 1
1 1/2,B 1 B,C 1 B,C 0 C 1 B,C
PROJECT SUMMARY:
BUSINESS OCCUPANCY
TYPE V-B CONSTRUCTION
FULLY SPRINKLERED
FLOOR AREA IN SQ. FT PER OCCUPANT = 100
BASEMENT 1,176 S.F. /100 = 11
FIRST FLOOR 12,469 S.F. /100 = 124
TOTAL OCCUPANCY 13,645 S.F. / 1000 = 135
EXIT WIDTH BASEMENT 7 X .2" = 1.4"
EXIT WIDTH FIRST FLOOR 83 X .2" = 16.6"
(EXIT WIDTH IS .15" PER OCCUPANT FOR EGRESS COMPONENT AND .2"
FOR STAIRS IN FULLY SPRINKLED BUILDINGS)
0' 1'
6" 3"
1'
Gr ap hi c S ca le
: 1 /2"
1'-
0"
0' 4"
8" 1'
2'
Gr ap hi c S ca le
: 3 /32
1'
-0
0'
8' Gr ap hi c S ca le : 1
/16
1' -0
0' 8'
4' Gr ap hi c S ca le
: 1 /8"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 1 /4"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 3 /8"
1'-
0"
0' 2'
4' 1' Gr ap hi c S ca le : 1
/2"
1'- 0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 3 /4"
1'-
0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 1
1' -0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:Consultant:
Spinklered
10/30/2020
BI
M
VI
SN
- A le xa nd ria
L au nd ry
/A le xa nd ria L au nd ry .rv t
/3 0/
:5
9:
P M
BUILDING CODE
GC TLZ
CONSTRUCTION DOCUMENTS 502-17-300
G-002
CONVERT ALEXANDRIA LAUNDRY
TO DISTRIBUTION STORAGE
ALEXANDRIA, LA
10/30/2020
16-
ALEXANDRIA,
LA
FE
FEC
LIFE SAFETY LEGEND LIFE SAFETY NOTES
FIRE EXTINGUISHER NOTES
FIRE EXTINGUISHER DETAILS
FE
C
FE
C
FEC
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FDC
F
L
L
D
MHO
FACP
FAAP
FIRE DEPARTMENT CONNECTION
EXIT
ILLUMINATED EXIT SIGN
FIRE ALARM - MANUAL PULL STATION
FIRE ALARM - STROBE / CHIME
FIRE ALARM - STROBE
SMOKE DETECTOR
MAGNETIC HOLD OPEN
FIRE ALARM CONTROL PANEL
FIRE ALARM ANUNCIATOR PANEL
EXTERIOR EMERGENCY LIGHTING
PATH OF TRAVEL
X'-X"
EGRESS DIRECTIONAL ARROW
TRAVEL DISTANCE START CIRCLE
XX"
DOOR CLEARANCE IN
INCHES(")
ONE HOUR RATED WALL
1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.
2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13
AND IS PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE
DETECTION SYSTEM.
3. WALL TYPES ARE DETAILED ON A-502 AND INDICATED ON THE
DIMENSIONED FLOOR PLAN ON A-102, A-103, & A-104.
4. REFER TO THIS DRAWING FOR MEANS OF EGRESS
5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.
6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE
MARSHAL.
1. EXTINGUISHER LEGEND:
10:ABC CLASS DRY CHEMICAL, MULTIPURPOSE EXTINGUISHER
2. EXTINGUISHERS MUST BE LOCATED, INSTALLED, SIZED AND MAINTAINED
ACCORDING TO NFPA 10.
3. EXTINGUISHERS (LESS THAN 40 LBS) MUST BE INSTALLED SO THAT THE HANDLE
OF THE EXTINGUISHER IS NOT MORE THAN 60" ABOVE THE FLOOR.
4. EXTINGUISHERS (OVER 40 LBS) MUST BE INSTALLED SO THAT THE TOP OF THE
EXTINGUISHER HANDLE IS NOT MORE THAN 42" ABOVE THE FLOOR.
5. THERE MUST BE A CLEARANCE OF AT LEAST 4" BETWEEN THE BOTTOM OF THE
EXTINGUISHER AND THE FLOOR.
6. ALL EXTINGUISHERS MUST BE PLACE FACING OUTWARD AND BE PROVIDED WITH
SIGNAGE THAT CAN BE READ FROM 25 FEET AWAY. LOCATE 12" BELOW CEILING
TO TOP OF PLACARD.
7. LOCKED OR BREAK-GLASS TYPE CABINETS ARE NOT ACCEPTABLE. CABINET
DOOR SHALL CLOSE WITH A CATCH OR LATCH MECHANISM. (NFPA-10)
8.
9.
FIRE EXTINGUISHER CABINET
HANDRAIL / CRASHRAIL
HOLD 2" AWAY FROM
EDGE OF CABINET
ELEVATION
PLAN
SIGNAGE (12" BELOW CEILING)
F I R E
F I R E
F I R E
E X T I N G U I S H E R
MAXIMUM
PROJECTION
2"
5' -0
3"
FIRE EXTINGUISHER PER NFPA 13.6.7.3 AND 13.6.7.4
INSTALL PER 13.6.8.1.3.8 = TYPE A WITHIN 75'-0" FOR TOTAL AREA
NOT TO EXCEED 11,250 SQ. FT. PER EXTINGUISHER.
BUILDING DATA:
FIRE RESISTANT CONSTRUCTION/
FIREPROOFING SCHEDULE
ITEM REQUIRED RATING
-EXTERIOR WALLS:
LOAD BEARING
NON LOAD BEARING
-FIRE/PARTY WALLS
(EXISTING)
-SHAFTS
-OCCUPANCY SEPARATION
-INTERIOR WALLS:
LOAD BEARING
NON LOAD BEARING
-COLUMNS
-BEAMS
-FLOOR/CEILING
-ROOF/CEILING
-SMOKE WALLS
-CORRIDOR WALLS
N/A
-STAIR ENCLOSURES 1
CONSTRUCT TO
LIMIT PASSAGE OF
SMOKE
METAL STUD WALL
SYSTEM; SEE WALL
TYPES
FIRE TREATED
WOOD BLOCKING
FIRE TREATED
WOOD BLOCKING
FIRE EXTINGUISHER
CABINET; SEMI
RECESSED; ADJUST
ROUGH OPENING TO
MEET MODEL NUMBER
REQUIREMENTS; SEE
SPECS
NOTE: ALL
PENETRATIONS IN
RATED WALL NEED TO
BE RATED
TOP OF EXTINGUISHER
METAL STUD WALL
SYSTEM; SEE WALL
TYPES
FIRE EXTINGUISHER
CABINET; SEMI
RECESSED, SEE
SPEC
FINISH FLOOR,
SEE
ROOM FINISH
SCHEDULE
FIRE TREATED
WOOD BLOCKING
PROVIDE SEALANT
AROUND CABINET,
TYP.- ALL SIDES
4'
0"
4 5 6 7 8 9 10 112
B
C
A
D
2772 SF
EMERGENCY LINEN STORAGE
105 276 SF
EMS
656 SF
EMERGENCY STORAGE
841 SF
LAUNDRY SUPPORT SPACE
474 SF
BREAKROOM
2459 SF
CLEAN LINEN
823 SF
SOILED LINEN
215 SF
WASH ROOM
103 SF
OFFICE
110F
105 SF
OFFICE
110G
114 SF
ELECTRICAL
326 SF
EQUIPMENT/ BATTERY CHARGING
110C
100 SF
OI&T CLOSET
110B
85 SF
OFFICE
107C
163 SF
CONFERENCE
107B
97 SF
OFFICE
107A
CART WASH/
MAINTENANCE
586 SF
CORRIDOR
TR
AV
EL
D
IS
TA
NC
E
: 5 0'-
0"
TR
AV
EL
D
IS
TA
NC
E
: 7 2'-
6"
TR
AV
EL
D
IS
TA
NC
E
: 1
6"
TR
AV
EL
D
IS
TA
NC
E
: 5 1'
-6
TRAVEL DISTANCE : 65' - 6"
TRAVEL DISTANCE : 57' - 6"
NEW
LANDING
NEW CONCRETE SIDEWALK
EXISTING
CONCRETE
EXISTING
CONCRETE
STOOP
TRAVEL DISTANCE : 66'-0"
203 SF
WOMENS
203 SF
MENS
374 SF
MECH. ROOM
111 SF
PUMP ROOM
EXISTING EXTERIOR COVERED AREA
TRAVEL DISTANCE : 34'-2"
TRAVEL DISTANCE : 39'-6"
TRAVEL DISTANCE : 99'-5"
91 SF
HOUSEKEEPING
110E
99 SF
COPY ROOM
107E
86 SF
OFFICE
107F
EXISTING
STAIRS -
DN
0' 1'
6" 3"
1'
Gr ap hi c S ca le
: 1 /2"
1'-
0"
0' 4"
8" 1'
2'
Gr ap hi c S ca le
: 3 /32
1'
-0
0'
8' Gr ap hi c S ca le : 1
/16
1' -0
0' 8'
4' Gr ap hi c S ca le
: 1 /8"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 1 /4"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 3 /8"
1'-
0"
0' 2'
4' 1' Gr ap hi c S ca le : 1
/2"
1'- 0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 3 /4"
1'-
0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 1
1' -0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:Consultant:
Spinklered
BUILDING KEY PLAN
1 2 3
10/30/2020
BI
M
VI
SN
- A le xa nd ria
L au nd ry
/A le xa nd ria L au nd ry .rv t
/3 0/
:5
9:
P M
LIFE SAFETY PLAN
GC TLZ
CONSTRUCTION DOCUMENTS 502-17-300
G-101
CONVERT ALEXANDRIA LAUNDRY
TO DISTRIBUTION STORAGE
ALEXANDRIA, LA
10/30/2020
16-
ALEXANDRIA,
LA
3/4" = 1'-0"2 FIRE EXTINGUISHER CABINET (F.E.C) PLAN
3/4" = 1'-0"3 FIRE EXTINGUISHER CABINET (F.E.C) SECTION
1/8" = 1'-0"1 LIFE SAFETY PLAN
SITE PLAN LEGEND
EXISTING BUILDING #13 N.I.C.
EXISTING
BUILDING #14 N.I.C.
EXISTING BUILDING #15 N.I.C.
EXISTING
BUILDING
#115 N.I.C.
EXISTING
HELIPORT
2495 SHREVEPORT HIGHWAY
PINEVILLE, LA 71360
BUILDING #16
NEW SIDE WALK
AND ACCESSIBLE
CONCRETE
RAMP. REGRADE
SITE TO
ACCOMODATE
RAMP SLOPE,
AND TO DIRECT
WATER AWAY
FROM RAMP
EXISTING
SLOPING
LANDSCAPING
EXISTING
SLOPING
LANDSCAPING
EXISTING
LANDSCAPING
EXISTING
RETAINING
WALL
EXISTING
STAIRS -
DN
EXISTING
PAVING
EXISTING
LANDSCAPING
EXISTING
PAVING
EXISTING
PAVING
EXISTING PARKING
EXISTING BUILDING #45 N.I.C.
VETERANS LOOP
EXISTING PARKING
EX
IS
TI
N
G P
AR
K
IN
G
EXISTING
DOCK CANOPY
EXISTING
STAIRS -
UP
EXISTING STAIR
TO BASEMENT
EXISTING STAIR
TO BASEMENT
EXISTING
LANDING
EXISTING
LANDING
NEW
LANDING
EXISTING
SIDEWALK
EXISTING
BUILDING
N.I.C.
EXISTING
LANDSCAPING
EXISTING
PAVING
EXISTING
STAIRS -
UP
EXISTING
COOLING
TOWER
EXISTING
TRANSFORMER
NEW
CONCRETE
RETAINING
WALL FOR
RAMP
NEW
CONCRETE
SIDEWALK
BUILDING WORK IN CONTRACT
CONCRETE PAVING IN CONTRACT
LANDSCAPE AREA IN CONTRACT
BUILDINGS NOT IN CONTRACT
0' 1'
6" 3"
1'
Gr ap hi c S ca le
: 1 /2"
1'-
0"
0' 4"
8" 1'
2'
Gr ap hi c S ca le
: 3 /32
1'
-0
0'
8' Gr ap hi c S ca le : 1
/16
1' -0
0' 8'
4' Gr ap hi c S ca le
: 1 /8"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 1 /4"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 3 /8"
1'-
0"
0' 2'
4' 1' Gr ap hi c S ca le : 1
/2"
1'- 0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 3 /4"
1'-
0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 1
1' -0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:Consultant:
Spinklered
10/30/2020
BI
M
VI
SN
- A le xa nd ria
L au nd ry
/A le xa nd ria L au nd ry .rv t
/3 0/
:5
9:
P M
SITE PLAN
GC TLZ
CONSTRUCTION DOCUMENTS 502-17-300
G-102
CONVERT ALEXANDRIA LAUNDRY
TO DISTRIBUTION STORAGE
ALEXANDRIA, LA
10/30/2020
16-
ALEXANDRIA,
LA
1/16" = 1'-0"1 SITE ORIENTATION PLAN
PLAN NORTH
2'-6" 8"
4d
4d
2 12" MIN.
'D' 'D' 'D' 'D'
SEE SCHEDULE
Ld (INCHES)
BAR DEVELOPMENT LENGTH (Ld) SCHEDULE f'c = 3000 PSI f'c = 4000 PSI
PLAN - OPENING TO 24"
PLAN OPENING 25" TO 60"
TYPICAL CONNECTION
GENERAL NOTES AND
TYPICAL DETAILS
S-001
SCALE
SCALE
SCALE
SCALE
SCALE
SCALE
Gr ap hi c S ca le
: 1 /2"
1'
-0
Gr ap hi c S ca le
: 3 /32
1'
-0
' Gr ap hi c S ca le : 1
/16
1' -0
Gr ap hi c S ca le
: 1 /8"
1'
-0
Gr ap hi c S ca le
: 1 /4"
1'
-0
Gr ap hi c S ca le
: 3 /8"
1'
-0
Gr ap hi c S ca le
: 1 /2"
1'
-0
Gr ap hi c S ca le
: 3 /4"
1'
-0
Gr ap hi c S ca le
: 1
1' -0
Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com
3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:
Spinklered
B I M
V
I S
N
A l e x a n d r i a
L u n d r y A l e x a n d r u n d r y r v t
A
M
502-17-300
ALEXANDRIA, LA
10/30/2020
ALEXANDRIA,
LA
Revisions: Date:
315 ARDEN AVE, SUITE 26, GLENDALE, CA 91203
www.schwabeng.com
Project No.: S6223180.00
CONSTRUCTION DOCUMENTS CONVERT ALEXANDRIA LAUNDRY
TO DISTRIBUTION STORAGE
AP HU
" M
IN
4" 4"
8"
1'- 0"
2'-6"
1'- 2"
T
HK
F
TG
4"
3'
MA
X.
8" THK
CONC. WALL
1'- 0"
1'- 0"
2'-0"
8"
4" T
HK
SL
AB
O
N
GR
AD
E
1'- 0"
(E) CONC. WALL
4'- 6"
M
AX
8"
PLAN AND DETAILS
S-201
SCALE
SCALE
SCALE
SCALE
SCALE
SCALE
BUILDING KEY PLAN
1 2 3
SCALE
Gr ap hi c S ca le
: 1 /2"
1'
-0
Gr ap hi c S ca le
: 3 /32
1'
-0
' Gr ap hi c S ca le : 1
/16
1' -0
Gr ap hi c S ca le
: 1 /8"
1'
-0
Gr ap hi c S ca le
: 1 /4"
1'
-0
Gr ap hi c S ca le
: 3 /8"
1'
-0
Gr ap hi c S ca le
: 1 /2"
1'
-0
Gr ap hi c S ca le
: 3 /4"
1'
-0
Gr ap hi c S ca le
: 1
1' -0
Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com
3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:
Spinklered
B
V
I S
N
A l e x a n d r u n d r y A l e x a n d r u n d r y r v t
A
M
502-17-300
ALEXANDRIA, LA
10/30/2020
ALEXANDRIA,
LA
Revisions: Date:
315 ARDEN AVE, SUITE 26, GLENDALE, CA 91203
www.schwabeng.com
Project No.: S6223180.00
CONSTRUCTION DOCUMENTS CONVERT ALEXANDRIA LAUNDRY
N
AC
AC
EF
EF4
EF
4 5 6 7 8 9 10 11
B
A
EF
1" MIN.
BUILDING KEY PLAN
ROOF FRAMING PLAN
AND DETAILS
S-202
SCALE
SCALE
SCALE
SCALE
SCALE
Gr ap hi c S ca le
: 1 /2"
1'
-0
Gr ap hi c S ca le
: 3 /32
1'
-0
' Gr ap hi c S ca le : 1
/16
1' -0
Gr ap hi c S ca le
: 1 /8"
1'
-0
Gr ap hi c S ca le
: 1 /4"
1'
-0
Gr ap hi c S ca le
: 3 /8"
1'
-0
Gr ap hi c S ca le
: 1 /2"
1'
-0
Gr ap hi c S ca le
: 3 /4"
1'
-0
Gr ap hi c S ca le
: 1
1' -0
Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com
3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:
Spinklered
B
V
I S
N
A l e x a n d r u n d r y A l e x a n d r u n d r y r v t
A
M
502-17-300
ALEXANDRIA, LA
10/30/2020
ALEXANDRIA,
LA
Revisions: Date:
315 ARDEN AVE, SUITE 26, GLENDALE, CA 91203
www.schwabeng.com
Project No.: S6223180.00
CONSTRUCTION DOCUMENTS CONVERT ALEXANDRIA LAUNDRY
GENERAL NOTES: KEY NOTES
STORAGE
B101
STORAGE
B102
EXISTING CRAWL SPACE
EXISTING SLAB ON GRADE
EXISTING CRAWL SPACE
EXISTING CRAWL SPACE
4 5 6 7 8 9 10 112
B
C
1 3
A
D
A-203
A-203
A-202
A-202
A-202
A-202
A-202
A-202
EXISTING
CRAWL SPACE
ACCESS DOOR
ABOVE
EXISTING
CRAWL SPACE
ACCESS DOOR
ABOVE
A-203
A-203
A-203
A-203
1. G.C. SHALL VERIFY DIMENSIONS OF OWNER
FURNISHED EQUIPMENT AND COORDINATE
INSTALLATION WITH ALL TRADES WHERE
REQUIRED.
2. REFER TO FINISH SHEETS FOR PARTITION
PROTECTION INFORMATION INCLUDING BUT NOT
LIMITED TO ALL CORNER GUARD TYPES AND
LOCATIONS.
3. G.C. SHALL INSTALL IN-WALL METAL BACKING FOR
ALL PARTITION-MOUNTED EQUIPMENT,
ACCESSORIES, PARTITION STOPS, ETC.
4. G.C. SHALL INSTALL FIRE-RETARDANT WOOD
BLOCKING WITHIN WALLS BASED ON CASEWORK
ELEVATIONS AND ALL INTERIOR PARTITION
ELEVATIONS.
5. ALL INTERIOR WALLS SHALL RECEIVE
5/8" TYPE 'X' GYPSUM BOARD.
6. G.C. SHALL PROVIDE UL APPROVED FIRE-
RESISTIVE PENETRATION SYSTEMS WHERE
PLUMBING IS LOCATED IN A FIRE-RATED
PARTITION ASSEMBLY.
7. STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSION TO POTENTIALLY CHANGE
DUE TO DISCREPANCY BETWEEN VA PROVIDED
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
8. CONTRACTOR TO FIELD VERIFY EXTISTING
STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY
VA AND ARCHITECT IF ANY DISCREPANCY FOUND
BETWEEN FIELD DIMENSIONS AND DRAWINGS.
9. ALL CORRIDOR WALLS SHALL BE CONSTRUCTED
AS NON-RATED SMOKE PARTITIONS.
10. EXTEND ALL RATED WALLS TO DECK PER UL
ASSEMBLY REQUIREMENTS. REFER TO G002 FOR
INTERIOR PARTITION TYPES & DETAILS.
11. REFER TO G002 FOR RATED PARTITION PRIORITY
AND RATED PARTITION INTERSECTIONS.
01 EXISTING STAIR TO REMAIN (NOT TO CODE)
02 NEW RAMP FOUNDATION FOOTING AND WALLS,
SEE STRUCTURAL DRAWINGS
03 NEW CONCRETE PLATFORM FOOTING AND
WALLS, SEE STRUCTURAL DRAWINGS
0' 1'
6" 3"
1'
Gr ap hi c S ca le
: 1 /2"
1'-
0"
0' 4"
8" 1'
2'
Gr ap hi c S ca le
: 3 /32
1'
-0
0'
8' Gr ap hi c S ca le : 1
/16
1' -0
0' 8'
4' Gr ap hi c S ca le
: 1 /8"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 1 /4"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 3 /8"
1'-
0"
0' 2'
4' 1' Gr ap hi c S ca le : 1
/2"
1'- 0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 3 /4"
1'-
0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 1
1' -0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:Consultant:
Spinklered
BUILDING KEY PLAN
10/30/2020
BI
M
VI
SN
- A le xa nd ria
L au nd ry
/A le xa nd ria L au nd ry .rv t
/3 0/
:5
7:
P M
BASEMENT PLAN
GC TLZ
CONSTRUCTION DOCUMENTS 502-17-300
A-100
CONVERT ALEXANDRIA LAUNDRY
TO DISTRIBUTION STORAGE
ALEXANDRIA, LA
10/30/2020
16-
ALEXANDRIA,
LA
1/8" = 1'-0"1 BASEMENT PLAN
C
FE
C
FEC
GENERAL NOTES: KEY NOTES
A-201
A-201
A-201
A-201
SCALE
SCALE
3 WASHERS
VENTLESS
DRYERS
FOLDING
TABLE
2772 SF
EMERGENCY LINEN STORAGE
276 SF
EMS
656 SF
EMERGENCY STORAGE
841 SF
LAUNDRY SUPPORT SPACE
474 SF
BREAKROOM
2459 SF
CLEAN LINEN
823 SF
SOILED LINEN
215 SF
WASH ROOM
MENDING TABLE
103 SF
OFFICE
110F
105 SF
OFFICE
110G
114 SF
ELECTRICAL
326 SF
EQUIPMENT/ BATTERY CHARGING
110C
100 SF
OI&T CLOSET
110B
85 SF
OFFICE
107C
163 SF
CONFERENCE
107B
97 SF
OFFICE
107A
5' - 0"
100 CARTS
30 CARTS
30 STACKABLE CARTS
CART WASH/
MAINTENANCE
FLOW THROUGH RACK
A-102
A-103
A-104
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
4 5 6 7 8 9 10 112
B
C
1 3
A
D
586 SF
CORRIDOR
VENDING
MACHINES
N.I.C
203 SF
MENS
203 SF
WOMENS
111 SF
PUMP ROOM
374 SF
MECH. ROOM
A-103
110D
CORRIDOR
FIELD VERIFY
158' - 2 1/4"
15' - 8 1/2" 1' - 2 1/2"
19' - 10 5/8" 22' - 0" 14' - 2" 14' - 3" 14' - 2 7/8" 14' - 3" 14' - 3 1/8" 14' - 2 1/2" 14' - 3" 13' - 6 5/8" 1' - 10 7/8"
/4
1'
5/
8"
/2
5/
8"
1'
1/
2"
A-203
A-203
A-202
A-202
A-202
A-202
A-202
A-202
/8
/2
R
M
C
91 SF
HOUSEKEEPING
110E
STACKED
WASHER/
DRYER
86 SF
OFFICE
107F
99 SF
COPY ROOM
107E
219 SF
CHECKIN
107D
DN
UP
UP
DN
28' - 1 13/16"
6 3 /4" 5' - 0"
5'
1/
8"
5' - 0"
/4
1' - 7 5/16"
5'
0"
NEW SIDEWALK
NEW
SIDEWALK
A-203
A-203
A-203
A-203
135.00°
NEW SIDEWALK
1. G.C. SHALL VERIFY DIMENSIONS OF OWNER
FURNISHED EQUIPMENT AND COORDINATE
INSTALLATION WITH ALL TRADES WHERE
REQUIRED.
2. REFER TO FINISH SHEETS FOR PARTITION
PROTECTION INFORMATION INCLUDING BUT NOT
LIMITED TO ALL CORNER GUARD TYPES AND
LOCATIONS.
3. G.C. SHALL INSTALL IN-WALL METAL BACKING FOR
ALL PARTITION-MOUNTED EQUIPMENT,
ACCESSORIES, PARTITION STOPS, ETC.
4. G.C. SHALL INSTALL FIRE-RETARDANT WOOD
BLOCKING WITHIN WALLS BASED ON CASEWORK
ELEVATIONS AND ALL INTERIOR PARTITION
ELEVATIONS.
5. ALL INTERIOR WALLS SHALL RECEIVE
5/8" TYPE 'X' GYPSUM BOARD.
6. G.C. SHALL PROVIDE UL APPROVED FIRE-
RESISTIVE PENETRATION SYSTEMS WHERE
PLUMBING IS LOCATED IN A FIRE-RATED
PARTITION ASSEMBLY.
7. STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSION TO POTENTIALLY CHANGE
DUE TO DISCREPANCY BETWEEN VA PROVIDED
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
8. CONTRACTOR TO FIELD VERIFY EXTISTING
STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY
VA AND ARCHITECT IF ANY DISCREPANCY FOUND
BETWEEN FIELD DIMENSIONS AND DRAWINGS.
9. ALL CORRIDOR WALLS SHALL BE CONSTRUCTED
AS NON-RATED SMOKE PARTITIONS.
10. EXTEND ALL RATED WALLS TO DECK PER UL
ASSEMBLY REQUIREMENTS. REFER TO G002 FOR
INTERIOR PARTITION TYPES & DETAILS.
11. REFER TO G002 FOR RATED PARTITION PRIORITY
AND RATED PARTITION INTERSECTIONS.
IF SLOPE IS REQUIRED PROVIDE HANDRAILS ON
SLOPING SECTION OF SIDEWALK. REFER TO
3/A-407 -TYPICAL RAMP SECTION. SLOPE TO BE
1:20 MAX IF SLOPE IS REQUIRED AND HANDRAILS
(IF REQUIRED) TO BE PAINTED COLOR "PT-6" ON
FINISH MATERIAL SCHEDULE ON SHEET A-602
VARIFY COLOR WITH VA.
0' 1'
6" 3"
1'
Gr ap hi c S ca le
: 1 /2"
1'-
0"
0' 4"
8" 1'
2'
Gr ap hi c S ca le
: 3 /32
1'
-0
0'
8' Gr ap hi c S ca le : 1
/16
1' -0
0' 8'
4' Gr ap hi c S ca le
: 1 /8"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 1 /4"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 3 /8"
1'-
0"
0' 2'
4' 1' Gr ap hi c S ca le : 1
/2"
1'- 0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 3 /4"
1'-
0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 1
1' -0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:Consultant:
Spinklered
BUILDING KEY PLAN
1 2 3
10/30/2020
BI
M
VI
SN
- A le xa nd ria
L au nd ry
/A le xa nd ria L au nd ry .rv t
/3 0/
:5
7:
P M
OVERALL FLOOR PLAN
GC TLZ
CONSTRUCTION DOCUMENTS 502-17-300
A-101
CONVERT ALEXANDRIA LAUNDRY
TO DISTRIBUTION STORAGE
ALEXANDRIA, LA
10/30/2020
16-
ALEXANDRIA,
LA
1/8" = 1'-0"1 FIRST FLOOR PLAN
GENERAL NOTES: KEY NOTES
2772 SF
EMERGENCY LINEN STORAGE
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
105B
105A
105C
B
C
1 3 A
D
/8
6'
0"
2'
1/
2" 8'
7"
5'
1/
4" 7'
7"
4'
3/
4" 8'
1"
4'
8" 7'
1/ 2"
2'
/8
6' - 6" 6' - 0"
374 SF
MECH. ROOM
6"
6"
7'
/4
19' - 11"
E1
E1
P04
E1
P04
P03 P03
E1
P03 P03
E1
P01
P01
E1
P03 P03
R01R01
E1
R02
R02
R02
E1E1E1
E1
E1
E1
E1
E1
E1
E1
E1
5'
1/
4"
5'
/2
4'
5/
8"
104B
104A
DN
114 SF
ELECTRICAL
A-407
1. G.C. SHALL VERIFY DIMENSIONS OF OWNER
FURNISHED EQUIPMENT AND COORDINATE
INSTALLATION WITH ALL TRADES WHERE
REQUIRED.
2. REFER TO FINISH SHEETS FOR PARTITION
PROTECTION INFORMATION INCLUDING BUT NOT
LIMITED TO ALL CORNER GUARD TYPES AND
LOCATIONS.
3. G.C. SHALL INSTALL IN-WALL METAL BACKING FOR
ALL PARTITION-MOUNTED EQUIPMENT,
ACCESSORIES, PARTITION STOPS, ETC.
4. G.C. SHALL INSTALL FIRE-RETARDANT WOOD
BLOCKING WITHIN WALLS BASED ON CASEWORK
ELEVATIONS AND ALL INTERIOR PARTITION
ELEVATIONS.
5. ALL INTERIOR WALLS SHALL RECEIVE
5/8" TYPE 'X' GYPSUM BOARD.
6. G.C. SHALL PROVIDE UL APPROVED FIRE-
RESISTIVE PENETRATION SYSTEMS WHERE
PLUMBING IS LOCATED IN A FIRE-RATED
PARTITION ASSEMBLY.
7. STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSION TO POTENTIALLY CHANGE
DUE TO DISCREPANCY BETWEEN VA PROVIDED
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
8. CONTRACTOR TO FIELD VERIFY EXTISTING
STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY
VA AND ARCHITECT IF ANY DISCREPANCY FOUND
BETWEEN FIELD DIMENSIONS AND DRAWINGS.
9. ALL CORRIDOR WALLS SHALL BE CONSTRUCTED
AS NON-RATED SMOKE PARTITIONS.
10. EXTEND ALL RATED WALLS TO DECK PER UL
ASSEMBLY REQUIREMENTS. REFER TO G002 FOR
INTERIOR PARTITION TYPES & DETAILS.
11. REFER TO G002 FOR RATED PARTITION PRIORITY
AND RATED PARTITION INTERSECTIONS.
VA TO NOTIFY A/E FIRM OF EQUIPMENT AND
SPACE NEEDS BEFORE A/E FIRM CAN DESIGN
INTERIOR SPACE.
02 EXISTING STEEL COLUMN TO REMAIN
03 EXISTING STAIR TO REMAIN
04 WALL TO WRAP EXISTING STRUCTURE
05 NEW ELEVATED CONCRETE LANDING, SEE
STRUCTRUAL DRAWINGS
06 NEW METAL GUARDRAILS
0' 1'
6" 3"
1'
Gr ap hi c S ca le
: 1 /2"
1'-
0"
0' 4"
8" 1'
2'
Gr ap hi c S ca le
: 3 /32
1'
-0
0'
8' Gr ap hi c S ca le : 1
/16
1' -0
0' 8'
4' Gr ap hi c S ca le
: 1 /8"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 1 /4"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 3 /8"
1'-
0"
0' 2'
4' 1' Gr ap hi c S ca le : 1
/2"
1'- 0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 3 /4"
1'-
0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 1
1' -0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:Consultant:
Spinklered
BUILDING KEY PLAN
10/30/2020
BI
M
VI
SN
- A le xa nd ria
L au nd ry
/A le xa nd ria L au nd ry .rv t
/3 0/
:5
7:
P M
ENLARGED FLOOR PLAN - AREA 1
GC TLZ
CONSTRUCTION DOCUMENTS 502-17-300
A-102
CONVERT ALEXANDRIA LAUNDRY
TO DISTRIBUTION STORAGE
ALEXANDRIA, LA
10/30/2020
16-
ALEXANDRIA,
LA
1/4" = 1'-0"1 AREA 1 FLOOR PLAN
(SEE WALL TYPES SHEET. 20 GAUGE DEFLECTION TRACK REQUIRED AT ALL PARTITION WALL CONNECTIONS TO STRUCTURE WITH
1/2" GAP BETWEEN GYP. AND TRACK)
Type Mark WALL TYPE DESCRIPTION
E1 EXISTING EXTERIOR BRICK WALL
P01 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE - (TAKE 6" ABOVE CEILING IN ROOMS
THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK)
P03 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE WITH ACOUSTICAL BATT INSULATION -
(TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK) P04 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT
INSULATION - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK) P05 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE WITH ACOUSTICAL BATT INSULATION -
60" HIGH TILE ON BATHROOM SIDE - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO
UNDERSIDE OF DECK)
P06 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT INSULATION - 60" HIGH TILE ON BATHROOM SIDES - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK) - REDUCE SCREW SPACING TO 12" BETWEEN SCREWS TO SUPPORT
TILES
P07 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE WITH ACOUSTICAL BATT INSULATION - FULL HEIGHT TILE ON SHOWER SIDE - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO
UNDERSIDE OF DECK)
P08 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT INSULATION - FULL HEIGHT TILE ON BOTH SIDES - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE
OTHERWISE TAKE TO UNDERSIDE OF DECK)
P09 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT INSULATION - 60" TILE ON BATHROOM SIDE AND FULL HIEGHT TILE ON SHOWER SIDE - (TAKE 6" ABOVE CEILING IN
ROOMS THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK)
P10 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT INSULATION - FULL HIEGHT TILE ON SHOWER SIDE - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE
OTHERWISE TAKE TO UNDERSIDE OF DECK)
R01 1HR RATED 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE TO DECK R02 1HR RATED 3-5/8" METAL STUD WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES TO DECK
FE
C
GENERAL NOTES: KEY NOTES
474 SF
BREAKROOM
72 SF
MENS SHOWER
101B
97 SF
OFFICE
107A
163 SF
CONFERENCE
107B
85 SF
OFFICE
107C
656 SF
EMERGENCY STORAGE
276 SF
EMS
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
A-300
4 5 6 7
B
C
A
D
107B
107A
107C
107D
103B
100A
100B
105B
105C
586 SF
CORRIDOR
100C
5'
5/
8"
8'
/1
6" 6'
5/
/2
7' - 3" 10' - 5" 13' - 7" 9' - 11" 16' - 10"
3'
2" 9'
7/ 8"
3/ 8"
/8
7' - 2 1/2" 5' - 5 3/8" 14' - 0 1/2" 8' - 9 3/8" 5' - 6 5/8" 8' - 10" 5' - 4"
2'
/1 6"
5'
5/
8"
5' - 4 7/8" 26' - 4 3/4"
P04P04 P04P04
P04
P04
P04P04
P04
P06
P04
P04
P04
P01 P01
P01
P01 P04
P01
P01
P04
P04
P04
P05
P05
R01R01
P03P03
P04
P01
P01P03
P03
P03 P03
P04
P01
P01
P03
P01
P01
P04
P04
P01
P04
103A
103C
203 SF
WOMENS
203 SF
MENS
71 SF
WOMANS SHOWER
102B
101A
102A
111 SF
PUMP ROOM
E1
6"
6"
6"
4"
7' - 4 7/16"
VENDING
MACHINES
N.I.C
P03P04 P04 P04 P04
P01
E1
E1
P04
E1
P04
P04
E1
E1
P04
E1
P04
841 SF
LAUNDRY SUPPORT SPACE
215 SF
WASH ROOM
114 SF
ELECTRICAL
2772 SF
EMERGENCY LINEN STORAGE
2772 SF
EMERGENCY LINEN STORAGE
02020202
M
C
5' - 3 1/2"
6' - 4"
109A
8'
7/
6"
6" 6"
6"
6" 6"
6"
99 SF
COPY ROOM
107E
86 SF
OFFICE
107F
219 SF
CHECKIN
107D
107E
107F
2"
A-405 1
A-405
R
P04
P04
P04
P04
P04
P04
P04
P0401
1. G.C. SHALL VERIFY DIMENSIONS OF OWNER
FURNISHED EQUIPMENT AND COORDINATE
INSTALLATION WITH ALL TRADES WHERE
REQUIRED.
2. REFER TO FINISH SHEETS FOR PARTITION
PROTECTION INFORMATION INCLUDING BUT NOT
LIMITED TO ALL CORNER GUARD TYPES AND
LOCATIONS.
3. G.C. SHALL INSTALL IN-WALL METAL BACKING FOR
ALL PARTITION-MOUNTED EQUIPMENT,
ACCESSORIES, PARTITION STOPS, ETC.
4. G.C. SHALL INSTALL FIRE-RETARDANT WOOD
BLOCKING WITHIN WALLS BASED ON CASEWORK
ELEVATIONS AND ALL INTERIOR PARTITION
ELEVATIONS.
5. ALL INTERIOR WALLS SHALL RECEIVE
5/8" TYPE 'X' GYPSUM BOARD.
6. G.C. SHALL PROVIDE UL APPROVED FIRE-
RESISTIVE PENETRATION SYSTEMS WHERE
PLUMBING IS LOCATED IN A FIRE-RATED
PARTITION ASSEMBLY.
7. STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSION TO POTENTIALLY CHANGE
DUE TO DISCREPANCY BETWEEN VA PROVIDED
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
8. CONTRACTOR TO FIELD VERIFY EXTISTING
STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY
VA AND ARCHITECT IF ANY DISCREPANCY FOUND
BETWEEN FIELD DIMENSIONS AND DRAWINGS.
9. ALL CORRIDOR WALLS SHALL BE CONSTRUCTED
AS NON-RATED SMOKE PARTITIONS.
10. EXTEND ALL RATED WALLS TO DECK PER UL
ASSEMBLY REQUIREMENTS. REFER TO G002 FOR
INTERIOR PARTITION TYPES & DETAILS.
11. REFER TO G002 FOR RATED PARTITION PRIORITY
AND RATED PARTITION INTERSECTIONS.
EQUIPMENT AND FURNITURE SPACE LAYOUT IS
FOR EXAMPLE ONLY OF CONFIGURATION USED
FOR DESIGN
02 EXISTING STEEL COLUMN TO REMAIN
60" FLATSCREEN TV N.I.C - CENTER ON THE
WALL HORIZONTALLY AND MOUNT WITH CENTER
OF SCREEN 5'-0" AFF. PROVIDE HORIZONTALLY
AND VERTICALLY ADJUSTABLE MOUNT
04 MICROWAVE N.I.C. - ON COUNTER (2'-10" AFF)
05 COFFE MAKER MACHINE N.I.C. - ON COUNTER
(2'-10" AFF)
A
111 SF
PUMP ROOM
656 SF
EMERGENCY STORAGE
E1
E1
E1
E1
P04
0' 1'
6" 3"
1'
Gr ap hi c S ca le
: 1 /2"
1'-
0"
0' 4"
8" 1'
2'
Gr ap hi c S ca le
: 3 /32
1'
-0
0'
8' Gr ap hi c S ca le : 1
/16
1' -0
0' 8'
4' Gr ap hi c S ca le
: 1 /8"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 1 /4"
1'-
0"
0' 2'
1' 4'
Gr ap hi c S ca le
: 3 /8"
1'-
0"
0' 2'
4' 1' Gr ap hi c S ca le : 1
/2"
1'- 0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 3 /4"
1'-
0"
0' 1'
2' 6"
Gr ap hi c S ca le
: 1
1' -0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
A/E:Consultant:
Spinklered
BUILDING KEY PLAN
10/30/2020
BI
M
VI
SN
- A le xa nd ria
L au nd ry
/A le xa nd ria L au nd ry .rv t
/3 0/
:5
7:
P M
ENLARGED FLOOR PLAN - AREA 2
GC TLZ
CONSTRUCTION DOCUMENTS 502-17-300
A-103
CONVERT ALEXANDRIA LAUNDRY
TO DISTRIBUTION STORAGE
ALEXANDRIA, LA
10/30/2020
16-
ALEXANDRIA,
LA
1/4" = 1'-0"1 AREA 2 FLOOR PLAN
(SEE WALL TYPES SHEET. 20 GAUGE DEFLECTION TRACK REQUIRED AT ALL PARTITION WALL CONNECTIONS TO STRUCTURE WITH
1/2" GAP BETWEEN GYP. AND TRACK)
Type Mark WALL TYPE DESCRIPTION
E1 EXISTING EXTERIOR BRICK WALL
P01 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE - (TAKE 6" ABOVE CEILING IN ROOMS
THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK)
P03 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE WITH ACOUSTICAL BATT INSULATION -
(TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK) P04 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT
INSULATION - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK) P05 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE WITH ACOUSTICAL BATT INSULATION -
60" HIGH TILE ON BATHROOM SIDE - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO
UNDERSIDE OF DECK)
P06 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT INSULATION - 60" HIGH TILE ON BATHROOM SIDES - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO UNDERSIDE OF DECK) - REDUCE SCREW SPACING TO 12" BETWEEN SCREWS TO SUPPORT
TILES
P07 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON ONE SIDE WITH ACOUSTICAL BATT INSULATION - FULL HEIGHT TILE ON SHOWER SIDE - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE OTHERWISE TAKE TO
UNDERSIDE OF DECK)
P08 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT INSULATION - FULL HEIGHT TILE ON BOTH SIDES - (TAKE 6" ABOVE CEILING IN ROOMS THAT HAVE ONE
OTHERWISE TAKE TO UNDERSIDE OF DECK)
P09 3-5/8" METAL STUDS WITH 5/8" TYPE X GYPSUM WALL BOARD ON BOTH SIDES WITH ACOUSTICAL BATT INSULATION - 60" TILE ON BATHROOM SIDE AND FULL HIEGHT TILE ON SHOWER SIDE - (TAKE 6"…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .