36C25019B0048-021.pdf
PDF 193 KB Posted
- Attached to
- Expand Engineering Support Space 539-19-201 Federal contract opportunity
- Solicitation number
- 36C25019B0048
About this file
This justification and approval document describes a sole source procurement by the Department of Veterans Affairs for physical access control system devices from Johnson Controls. The Veterans Administration Cincinnati VAMC requires expansion of its existing Johnson Controls physical access control system for a project to expand engineering support space. The estimated value of the access control system is $19,000. Market research found that physical access control systems use proprietary software, preventing interoperability between devices from different manufacturers. Using Johnson Controls devices will allow the new installation to communicate with the existing sole source system, maintaining security and device functionality. Approval is granted for this sole source procurement due to the need for systems interoperability and to ensure safety and security within the facility.
In a related notice, the Department of Veterans Affairs solicits bids for the engineering support space expansion project requiring the physical access control system devices. Bids will be accepted through the Federal Business Opportunities website starting in September 2019. The $500,000 to $1,000,000 project has a 275-day performance period and requires payment and performance bonds. The solicitation is a 100% set-aside for verified veteran-owned small businesses under applicable size standards and North American Industry Classification codes. Offerors must meet registration, size, and responsibility requirements to be eligible for award.
36C25019B0048 Johnson Controls System Sole Source Justification.pdf
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF VETERANS AFFAIRS
Justification and Approval
For
Other Than Full and Open Competition
Valcom Overhead Paging System
1. Contracting Activity: Department of Veterans Affairs, Network Contracting Office (NCO)
10, 260 E. University Avenue, Cincinnati, OH in conjunction with VISN 10, VAMC Medical
Center, Engineering Service (138), 3200 Vine Street, Cincinnati, OH 45220. Purchase request number 539-19-2-6905-0025, Project number 539-19-201, Expand Engineering
Support Space.
2. Brief Description of Supplies/ Services required and the intended use/Estimated
Amount:
Engineering Service is requesting approval to use other than full and open competition to solicit a Brand Name Only for the Physical Access Control System (PACS) manufactured by
Johnson Controls for use on Project No. 539-19-201 Expand Engineering Support Space.
The expansion of the existing Security Access Control System involves PACS devices, consisting of Controls/Communications Panels, Electronic Security Management System, Door Control Modules, Card Reader/Keypad Combination, Portal Control Devices, Door
Status Indicators, and Entry Control Devices. This project will be awarded as a new Firm-
Fixed Price contract. The estimated value for the PACS is $19,000.00.
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:
The PACS devices that are to be installed as part of this project represent an extension of the existing Johnson Controls PACS at our facility. As such, each new device must tie into and communicate with the existing Facility PACS, which is manufactured by Johnson. Each device in a PACS, whether it’s a card reader or control panel, constantly communicates with the front end of the PACS. This allows the system to monitor each and every device, so that it cannot only receive alarms, but also can detect failures of the device as well – which is a critical element in any PACS. Software conflicts would make it difficult to impossible for devices by another manufacturer to communicate with the existing Johnson System, and could result in circumventing the Physical Security of the Medical Center. Research has shown that in the industry, it is standard for each PACS to have their own proprietary software which prohibits communication between different manufacturers.
4. Description of market research conducted and results or statement why it was not conducted:
Research has shown that in the industry, it is standard for each PACS to have their own proprietary software which prohibits communication between different manufacturers. To ensure safety to employees all security entry/exits must be the same and to make sure all devices are compatible to the new devises, hardware and software.
5. Requirements Certification: I certify that the requirement outlined in this justification is a
Bona Fide Need of the Department of Veterans Affairs and that the supporting data under my cognizance, which are included in the justification, are accurate and complete to the best of my knowledge and belief.
Zachary Schmidt Date
Project Engineer, Engineering Service
VAMC – Cincinnati, OH