36C25019B0048-020.pdf
PDF Posted
- Attached to
- Expand Engineering Support Space 539-19-201 Federal contract opportunity
- Solicitation number
- 36C25019B0048
About this file
This justification and approval document outlines a sole source procurement by the Department of Veterans Affairs for a Honeywell brand fire alarm system. The Veterans Administration Cincinnati VAMC intends to expand an existing Honeywell fire alarm system at a cost of $15,000. Intermixing manufacturers would compromise the ability to respond efficiently to alarms and void the UL listing of the integrated system. The solicitation will be a 100% small business set-aside with a preference for verified veteran-owned small businesses. Offerors must be registered in the Vendor Information Pages and SAM databases. The projected value is between $500,000 and $1,000,000 under NAICS code 236220. The response time is 275 calendar days from the notice to proceed. Payment and performance bonds will be required.
36C25019B0048 Honeywell Fire Alarm System Sole Source Justification.pdf
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF VETERANS AFFAIRS
Justification and Approval
For
Other Than Full and Open Competition
Valcom Overhead Paging System
1. Contracting Activity: Department of Veterans Affairs, Network Contracting Office (NCO)
10, 260 E. University Avenue, Cincinnati, OH in conjunction with VISN 10, VAMC Medical
Center, Engineering Service (138), 3200 Vine Street, Cincinnati, OH 45220. Purchase request number 539-19-2-6905-0025, Project number 539-19-201, Expand Engineering
Support Space.
2. Brief Description of Supplies/ Services required and the intended use/Estimated
Amount:
Engineering Service is requesting approval to use other than full and open competition to solicit a Brand Name Only for Honeywell brand Fire Alarm System for use on Project No.
539-19-201 Expand Engineering Support Space. This includes an expansion of the existing fire alarm system involving smoke detectors, duct detectors, sprinkler supervisory switches, electromagnetic door holders, manual fire alarm stations, water flow and pressure switches, speakers, strobes and a voice annunciation system. This project will be awarded as a new
Firm-Fixed Price contract. The estimated value for the fire alarm system is $15,000.00.
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:
The fire alarm devices that are to be installed under this project represent an extension of the existing Fire Alarm System at our facility. As such, each new device must tie into and communicate with the existing Facility Fire Alarm System, which is manufactured by
Honeywell. Each device in a fire alarm system, whether it’s a smoke detector or supervisory switch, constantly communicates with the front end of the fire alarm system. This allows the system to monitor each and every device, so that it can not only receive alarms, but also can detect failures of the device as well – which is a critical element in any fire alarm system. In addition, the software allows for a graphics package, which displays the floor plans of the entire facility depicting each and every fire alarm device. This allows for fast response in any alarm situation, as the system can tell Fire Fighters and VA Police the exact location of the device in alarm. Besides the fact that software conflicts would make it difficult to impossible for devices by another manufacturer to communicate with the existing Honeywell System, it would void the warranty and the UL Listing of the fire alarm system. A UL Listed Fire
Alarm System is a Life Safety Code requirement. Maintaining the warranty and UL Listing of the Fire Alarm System is critical and cannot be jeopardized.
4. Description of market research conducted and results or statement why it was not conducted:
Research has shown that in the industry, it is standard for each fire alarm system to have their own proprietary software which prohibits communication between different manufacturers.
There is just too much at risk from a Life Safety Code Standpoint to attempt to intermingle manufacturers on a Fire Alarm System; this facility has a Honeywell Fire Alarm System, and we should only add devices to it that are manufactured by Honeywell. Additionally, attempting to introduce a fire alarm from a different manufacturer with different software would no doubt compromise the ability of staff to respond efficiently, let along the issues of how it would communicate with the existing Honeywell fire alarm system.
5. Requirements Certification: I certify that the requirement outlined in this justification is a
Bona Fide Need of the Department of Veterans Affairs and that the supporting data under my cognizance, which are included in the justification, are accurate and complete to the best of my knowledge and belief.
Zachary Schmidt Date
Project Engineer, Engineering Service
VAMC – Cincinnati, OH
6. Contracting Officer’s Certification
Yvonne Demorest
Contracting Officer
VHACINSchmiZ Typewritten Text 3/27/2019
| 2019-03-27T10:20:12-0400 | |
| Zachary Schmidt |
| 2019-04-02T09:30:40-0400 | |
| Yvonne Demorest 497489 |
File details come from the government source that posted it. Updated .