36C25018B0823-011.pdf
PDF 11 MB Posted
- Attached to
- Replace Windows-Various Buildings 515-14-103 Federal contract opportunity
- Solicitation number
- 36C25018B0823
About this file
36C25018B0823 S02 - Drawings - 515-14-103_Part9.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25018B0823-0001001.pdf | ||
| 36C25018B0823-0001000.docx | DOCX document | |
| 36C25018B0823-007.pdf | ||
| 36C25018B0823-014.pdf | ||
| 36C25018B0823-009.pdf | ||
| 36C25018B0823-004.pdf | ||
| 36C25018B0823-019.pdf | ||
| 36C25018B0823-001.docx | DOCX document | |
| 36C25018B0823-008.pdf | ||
| 36C25018B0823-005.pdf | ||
| 36C25018B0823-015.pdf | ||
| 36C25018B0823-002.pdf | ||
| 36C25018B0823-003.pdf | ||
| 36C25018B0823-013.pdf | ||
| 36C25018B0823-018.docx | DOCX document | |
| 36C25018B0823-006.pdf | ||
| 36C25018B0823-017.pdf | ||
| 36C25018B0823-012.pdf | ||
| 36C25018B0823-010.pdf | ||
| 36C25018B0823-016.pdf | ||
| 36C25018B0823-000.docx | DOCX document |
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.netVIRIDIAN
ARCHITECTURAL DESIGN INC.
100% BID DOCUMENTS
1. DIMENSIONS ARE TO EDGE OF WALL OR TO FACE OF WALL UNLESS NOTED
OTHERWISE.
2. BUILDING DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY ALL
DIMENSIONS PRIOR TO BEGINNING OF CONSTRUCTION.
3. GENERAL CONTRACTOR TO COORDINATE ALL ASSOCIATED WORK WITH ALL
SUB-CONTRACTORS.
4. ALL MATERIALS IN DEMOLITION DETAILS INDICATED AS DASHED ARE TO BE
REMOVED, SEE DETAILS ON THE A700 SHEETS. THIS INCLUDES ALL FINISHES AND
MATERIALS NOT SPECIFICALLY CALLED OUT BUT PERTAINING TO THE INTENDED
SCOPE.
5. CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE SITE TO BECOME
FAMILIAR WITH THE EXISTING CONDITIONS. THESE DRAWINGS SHALL SERVE TO AID
THE CONTRACTOR IN THE EVALUATION OF THE EXTENT OF DEMOLITION : BUT SHALL
NOT BE HELD TO BE ALL INCLUSIVE.
6. CONTRACTORS SHALL FIELD INSPECT ALL DEMOLITION WORK PRIOR TO REMOVAL,
TO INSURE SUCH REMOVAL DOES NOT IMPAIR STRUCTURAL INTEGRITY OF THE
EXISTING BUILDING . IF THE INSPECTION INDICATES THAT THE STRUCTURAL
INTEGRITY MAY BE COMPROMISED, NOTIFY THE ARCHITECT / ENGINEER
IMMEDIATELY.
7. ALL CONTRACTORS ARE RESPONSIBLE FOR CLEANING SITE TO THE BEST OF THEIR
ABILITIES AT THE END OF EACH WORK DAY.
8. THE CONTRACTOR RESPONSIBLE FOR GENERAL DEMOLITION WORK SHALL
COORDINATE WITH THE ELECTRICAL CONTRACTOR, ALL NECESSARY DEMOLITION TO
OCCUR WHERE ELECTRICAL ACCESS WORK MUST TAKE PLACE.
UPON COMPLETION OF ACCESS WORK, THE GENERAL CONTRACTOR SHALL
REPAIR AND REFINISH ACCESS AREAS TO APPEAR AS THOUGH NO ACCESS
WORK HAD OCCURRED.
MATERIALS NECESSARY FOR THIS WORK SHALL BE COMPATIBLE WITH THE
EXISTING CONSTRUCTION AND FINISH MATERIALS AND COLORS SHALL BLEND IN
WITH THE SURROUNDING SURFACES.
CONTRACTORS SHALL COORDINATE ALL DEMOLITION AND RECONSTRUCTION
WORK WITH OTHER TRADES, TO BE ASSURED THAT WORK IN EITHER OF THESE
AREAS IS COMPLEMENTARY TO THE OTHER AND COMPLETE IN ALL RESPECTS.
9. WHERE ANCHORING DEVICES, ADHESIVES OR MASTICS OCCUR ON EXISTING
CONSTRUCTION THEY SHALL BE REMOVED FROM ALL SURFACES, REPAIRED AND
FINISHED TO MATCH ADJACENT SURFACES.
10. CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE
INSTALLATION OF NEW CONSTRUCTION, WHETHER OR NOT IT IS SPECIFICALLY
SHOWN OR NOTED IN THESE DOCUMENTS.
11. ALL CONTRACTORS TO VERIFY STAGING AND STORAGE LOCATIONS OF ALL
MATERIALS AND EQUIPMENT WITH OWNER PRIOR TO BEGINNING OF CONSTRUCTION.
12. THE GC SHALL TEMPORARILY RELOCATE FURNITURE WITHIN THE SPACE AS
NECESSARY TO COMPLETE THE WORK AND REINSTALL IN ITS ORIGINAL LOCATION.
THE VA WILL REMOVE OR OTHERWISE SECURE ALL PIH, PPI, AND PERSONAL
PROPRTY. COORDINATE WITH COR.
13. ALL CONTRACTORS RESPONSIBLE FOR ANY DAMAGES CAUSED BY THEM DURING
THE CONSTRUCTION PROCESS. IN THE EVENT OF ANY DAMAGES CONTRACTOR IS
TO CONTACT COR IMMEDIATELY; PRIOR TO THE END OF THE DAY OF
CONSTRUCTION.
14. FOR FURTHER INFORMATION WITH REGARD TO THE EXACT EXTENT OF DEMOLITION,
SEE THE CONSTRUCTION PLANS WHICH ILLUSTRATE THE ADJACENT NEW
CONSTRUCTION.
THESE NOTES APPLY TO ALL DEMOLITION DRAWINGS AND TO ALL CONTRACTORS AND / OR
SUBCONTRACTORS THAT WORK WITHIN THIS BUILDING.
WINDOW SCHEDULE CONTINUED ON SHEET 05.AS702.
1. REMOVE EXISTING WINDOW UNIT IN ITS ENTIRETY, INCLUDING ALUMINUM SASHES,
FRAMING, PANNING, AND TRIM. REMOVE ANY REMAINING WINDOW MATERIAL
FROM ALL PREVIOUS WINDOW UNITS INCLUDING, BUT NOT LIMITED TO, FRAMING,
FASTENERS, ANCHORS, STOOLS, APRONS, BLOCKING / BUCKS (WOOD AND / OR
METAL) , AND WEIGHTS. TAKE CARE NOT TO DISTURB INTERIOR PERIMETER
PLASTER WORK OR FINISHED DRYWALL ROUGH OPENING. STRUCTURAL ELEMENTS,
INCLUDING HEADERS, LINTELS, AND STRUCTURAL MULLIONS TO REMAIN IN PLACE.
CONCRETE OR MASONRY SILLS TO REMAIN IN PLACE. REMOVE ANY OTHER
MATERIAL PRESENT SO THAT ONLY THE WINDOW ROUGH OPENING, SILL, AND
INTERIOR PERIMETER PLASTER WORK OR FINISHED DRYWALL REMAIN. INSULATE
ANY WALL CAVITIES EXPOSED BY WINDOW REMOVAL. SEE DETAILS AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. REMOVE EXISTING ALUMINUM WINDOW IN ITS ENTIRETY, INCLUDING SASHES,
FRAMING, AND ANY OTHER WINDOW MATERIAL FROM PREVIOUS INSTALLATIONS,
SO THAT ONLY THE ROUGH MASONRY OPENING REMAINS. SEE DETAILS FOR
ADDITIONAL INFORMATION.
3. REMOVE WINDOW AND / OR WALL INFILL MATERIAL TO ROUGH OPENING
INCLUDING CLADDING, BRICK, STUDS, INSULATION, DRYWALL, WINDOWS, AND
ANY OTHER MATERIALS. SEE DETAILS FOR ADDITIONAL INFORMATION.
4. REMOVE INFILL PANEL OR DOOR PANEL AND ANY FRAMING MATERIAL FROM
WINDOW OPENING SO THAT ONLY A ROUGH MASONRY OPENING (WITH LENTIL)
REMAINS. SEE DETAILS FOR ADDITIONAL INFORMATION.
5. LOUVER, VENT, OR OTHER MECHANICAL DEVICE TO REMAIN IN OPENING.
TEMPORARILY DISCONNECT FROM MECHANICAL EQUIPMENT AND ELECTRICAL
SERVICE. TEMPORARILY SUPPORT FOR REMOVAL OF WINDOW ABOVE OR BELOW
IN SAME WINDOW OPENING. INSTALL NEW FRAMING SUPPORT FOR EQUIPMENT.
INSTALL NEW ALUMINUM DOUBLE-GLAZED INSULATED WINDOW IN REMAINING
OPENING. SEE WINDOW SCHEDULE AND DETAILS FOR ADDITIONAL INFORMATION.
6. PROVIDE AND INSTALL NEW DOUBLE-GLAZED INSULATED ALUMINUM WINDOW
UNIT. SIZE TO FIT INTO ROUGH OPENING. WINDOW TO OPERATE AS INDICATED ON
WINDOW SCHEDULE. SEE WINDOW SCHEDULE FOR APPROXIMATE DIMENSIONS
AND DETAILS. SEE SPECIFICATION FOR ADDITIONAL INFORMATION. CONTRACTOR
TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS.
7. PROVIDE AND INSTALL BLAST RESISTANT WINDOW FILM ON ALL SASHES OF THIS
WINDOW UNIT. PRODUCT BASIS OF DESIGN: 3M ULTRA 800 OR EQUAL
APPROVED BY THE VA. SEE SPECIFICATION FOR ADDITIONAL INFORMATION.
8. RELOCATE ELECTRICAL OUTLET AND REROUTE IN-WALL CONDUIT FROM J-BOX OR
PANEL TO NEW ADJACENT LOCATION OUTSIDE AREA OF WINDOW REPLACEMENT.
9. ADJUST INTERIOR HVAC DUCTING SO THAT VENT OCCURS AT TOP SASH.
10. PROVIDE AND INSTALL NEW 1/2" THICK SOLID SURFACE WINDOW STOOL. SEE
FINISH SCHEDULE, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
11. PROVIDE AND INSTALL NEW SECURITY SCREEN AT WINDOW INTERIOR TO REPLACE
EXISTING. NEW SECURITY SCREEN SHALL CONFORM TO VA SECURITY DESIGN
GUIDE. SECURITY SCREEN SHALL REMAIN FUNCTIONAL EXCEPT WHEN BEING
REPLACED. CONTRACTOR SHALL REMOVE AND REPLACE SECURITY SCREEN
DURING WORKING HOURS. WINDOW SHALL NOT BE LEFT UNSECURED AT ANY
TIME.
12. REMOVE SECURITY SCREEN AND ALL ASSOCIATED HARDWARE FROM EXTERIOR
OR INTERIOR OF WINDOW. TEMPORARILY CATALOGUE AND STORE FOR
REINSTALLATION. CLEAN, REFINISH, AND REINSTALL AT SAME LOCATION AFTER
CORRESPONDING WINDOW HAS BEEN INSTALLED. PROVIDE ANY ADDITIONAL TRIM
AND HARDWARE REQUIRED FOR COMPLETE AND SECURE INSTALLATION.
13. PROVIDE AND INSTALL NEW EXTERIOR SECURITY SCREEN TO MATCH ADJACENT.
FINISH TO MATCH ADJACENT.
14. REMOVE AND TURN WINDOW AIR CONDITIONING UNIT (AC) OVER TO VA
MECHANICAL MAINTENANCE SHOP DURING CONSTRUCTION, COORDINATE WITH
COR. CLEAN AC UNIT (INTERIOR AND EXTERIOR), AND REINSTALL FOLLOWING
CORRESPONDING WINDOW REPLACEMENT WITH COMMERCIAL GRADE MOUNTING
BRACKET, GASKETS, 1" INSULATED PANEL, WEATHERPROOFING, FASTENERS, AND
OTHER MATERIALS AS SHOWN IN AC MOUNTING DETAIL 3/AS1101. INSTALL
EXISTING AC UNIT AND CAULK AROUND ALL EDGES TO ELIMINATE AIR INFILTRATION
THROUGH WINDOW OPENING. COORDINATE WITH COR.
15. REMOVE ALL BLINDS, CURTAINS, SHADES, AND ASSOCIATED HARDWARE IN THEIR
ENTIRETY. PROVIDE AND INSTALL NEW 1" ALUMINUM HORIZONTAL BLINDS AND
CORRESPONDING HARDWARE. SEE SPECIFICATION FOR ADDITIONAL
INFORMATION.
16. RELOCATE SURFACE MOUNTED ELECTRICAL OUTLET AND SURFACE CONDUIT TO
ADJACENT LOCATION OUTSIDE OF AREA OF WINDOW REPLACEMENT. REWIRE AS
NEEDED FROM J-BOX OR PANEL.
17. CAREFULLY REMOVE DRYWALL OR PLASTER CEILING OR BULKHEAD AS NEEDED
FOR REMOVAL OF WINDOW MATERIAL. CONSTRUCT NEW DRYWALL AND LIGHT
GAUGE STEEL FRAMING POCKET/ BULKHEAD AT CEILING AROUND NEW WINDOW
OPENING. SEE SPECIFICATIONS AND DETAILS 4&5 / AS1101 FOR ADDITIONAL
INFORMATION.
18. CAREFULLY REMOVE PORTION OF WALL AS NECESSARY FOR REMOVAL OF
WINDOW MATERIAL. PATCH AND REPAIR TO MATCH ADJACENT AFTER NEW
WINDOW INSTALLATION.
19. CAREFULLY REMOVE PORTION OF SUSPENDED ACOUSTICAL TILE CEILING AS
NEEDED FOR REMOVAL OF WINDOW MATERIAL. CONSTRUCT NEW DRYWALL AND
LIGHT GAUGE STEEL FRAMING POCKET/ BULKHEAD AT CEILING AROUND NEW
WINDOW OPENING. REPAIR SUSPENDED ACOUSTICAL TILE CEILING AROUND NEW
POCKET/BULKHEAD SO THAT NO GAPS IN THE CEILING REMAIN. SEE
SPECIFICATIONS AND DETAILS 6&7 / AS1101 FOR ADDITIONAL INFORMATION.
20. REPAIR AND RESTORE DRYWALL / PLASTER WALL SURFACES ADJACENT TO
WINDOW OPENING AND REFINISH (PAINT OR WALL COVERING) TO MATCH
ADJACENT.
21. CLEAN ALL ADHESIVES, DEBRIS, CAULKING, OR OTHER MATERIALS FROM
MASONRY OPENING. REFINISH TO MATCH ADJACENT MASONRY WALL.
22. REMOVE SPEAKER WIRING / CONDUIT RUNNING THROUGH EXISTING WINDOW
FRAME. CAP AT INTERIOR FOR FUTURE USE.
23. 1" INSULATED WINDOW GLASS TO BE FROSTED AT UPPER AND LOWER SASHES.
24. 1" INSULATED WINDOW GLASS TO BE FROSTED AT LOWER SASH ONLY.
25. 1" INSULATED WINDOW GLASS TO BE WIRE SAFETY GLASS.
26. REMOVE EXISTING LIGHT FIXTURE AT WINDOW OPENING IN ITS ENTIRETY. CAP
ELECTRICAL. PATCH AND REFINISH CEILING / BULKHEAD TO MATCH ADJACENT.
27. DO NOT DISTURB EXISTING WALL INFILL. ALL WINDOW REPLACEMENT WORK TO BE
PERFORMED FROM THE EXTERIOR FOR HUNG UNITS COVERED BY AN INTERIOR
WALL, LOCK SASHES IN PLACE AND SEAL AROUND ALL EDGES OF OPERABLE
SASH, INTERIOR AND EXTERIOR. SEE DETAILS 1&2 / AS1101.
28. TEMPORARILY REMOVE, CATALOGUE, AND STORE EXISTING BLACKOUT SHADE
AND ALL CORRESPONDING HARDWARE INCLUDING CEILING POCKETS, BLACKOUT
CHANNELS, AND MOUNTING DEVICES. CLEAN AND REINSTALL FOLLOWING
CORRESPONDING WINDOW REPLACEMENT. PROVIDE AND INSTALL ANY
ADDITIONAL HARDWARE REQUIRED FOR SECURE LIGHT-BLOCKING INSTALLATION.
SEE SPECIFICATION FOR ADDITIONAL INFORMATION.
29. INFILL REMAINING ROUGH OPENING TO MATCH ADJACENT WALL CONSTRUCTION.
30. PROVIDE FROSTED GLASS AT RESTROOM HALF OF WINDOW ONLY.
31. PROVIDE DOOR AT HALF OF WINDOW OPENING AS INDICATED ON THE ELEVATION
AND DETAIL DRAWINGS.
32. PROVIDE NEW DECORATIVE DOUBLE-GLAZED INSULATED ALUMINUM WINDOW
WITH APPLIED MUNTINS. SEE WINDOW SCHEDULE FOR ADDITIONAL INFORMATION
AND DETAILS.
33. 1" INSULATED GLASS TO BE COLORED AT TOP PANE. COLOR TO MATCH EXISTING.
34. REMOVE CONDUIT ADJACENT TO WINDOW. RELOCATE SO NOT TO INTERFERE
WITH WINDOW OPENING.
35. INSULATED INFILL PANEL TO BE GLAZED INTO WINDOW SASH INDICATED IN
DRAWING. CUT OPENING IN INFILL PANEL AS NEED FOR RE-INSTALLATION OF
MECHANICAL EQUIPMENT, LOUVER, OR VENT. RECONNECT EQUIPMENT, LOUVER,
OR VENT AT THE INTERIOR AND ALIGN WITH ALL EXISTING ADJACENT DUCTWORK
OR OTHER MECHANICAL EQUIPMENT.
36. INTERIOR METAL SECURITY SCREEN TO BE REPLACED. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
37. CONTRACTOR TO PROTECT FLOOR. COORDINATE WITH COR.
SH SINGLE HUNG
DH DOUBLE HUNG
FXD FIXED
CASE CASEMENT
HOP HOPPER
AWN AWNING
SL SLIDER
HS HORIZONTAL SLIDER
ALS ALUMINUM STOREFRONT
DC DROPPED CEILING (ACT)
ACT ACOUSTICAL TILE CEILING
DW DRYWALL / PLASTER
RO ROUGH OPENING
BO BOTTOM OF
TO TOP OF
WC WALL COVERING
VWC VINYL WALL COVERING
WD WOOD
SCRN SCREEN
MTL METAL
SS SOLID SURFACE
CT CERAMIC TILE
VIF VERIFY IN FIELD
NOTE:
ASBESTOS ABATEMENT: THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL
CONFIRMATION TESTING AND ABATEMENT OF HAZARDOUS MATERIALS IN
RENOVATION AREAS. SEE SPECIFICATIONS, EXISTING ASBESTOS SURVEY, AND ACM
TABLE ON SHEET GI004 FOR ADDITIONAL INFORMATION. COORDINATE WITH COR.
NOTE:
LEAD CONTAINING PAINT SUSPECTED IN ALL BUILDINGS. CONTRACTOR IS
RESPONSIBLE FOR ALL TESTING AND ABATEMENT OF LEAD PAINT.
NOTE:
CONTRACTOR TO REMOVE ALL RUST IN ITS ENTIRETY FROM STEEL LINTELS AND
PRIME AND PAINT WHITE TO MATCH NEW WINDOW. SEE SPECIFICATIONS FOR
ADDITION INFORMATION.
NOTE:
WINDOW DRAWINGS DO NOT REPRESENT A SPECIFIC PRODUCT OR MANUFACTURER.
THEY INTEND TO DESCRIBE WINDOW TYPES, GENERAL FEATURES, AND GENERAL
INSTALLATION REQUIREMENTS. ALL MEASUREMENTS AND EXISTING CONDITIONS
MUST BE VERIFIED IN FIELD BY THE CONTRACTOR. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
NOTE:
WINDOW MUNTINS TO BE 7
8" WIDE AND LOCATED BETWEEN IGU GLASS LAYERS ONLY.
RESULTING "DIVIDED" LITES SHALL BE APPROX. 9"-12" WIDE. SEE WINDOW
ELEVATIONS FOR GUIDANCE. ALL WINDOW MUNTIN DIMENSIONS AND LOCATIONS TO
BE INDICATED IN SHOP DRAWINGS FOR REVIEW BY THE VA AND ARCHITECT.
NOTE:
NOT ALL WINDOW REPLACEMENT NOTES APPEAR ON THIS SHEET.
NOTE:
ALL WINDOW FRAME DEPTHS TO MATCH EXISTING.
BUILDING 5 EXISTING WINDOW CONDITIONS REPLACEMENT WINDOWS
ROOM INTERIOR ROUGH OPENING EXTERIOR ROUGH OPENING WALL THICKNESS OPERATION FINISHES SILL SIZE & TYPE CEILING CONDITION SECURTIY SCREEN A/C OPENING ADDITIONAL COMMENTS ELECTRICAL ELEVATION /
OPERATION
DETAILS REMARKS
A001 CRAWL SPACE MTL DOOR 3' 2-1/2" X 2' 2-1/2" -- -- -- -- -- -- -- -- -- 5.E /HOP 2,3/05.AS703 4,6
A002 CRAWL SPACE NO ACCESS - CRAWLSPACE 3' 2-1/2" X 2' 3" 15" HOP -- -- -- MTL SCRN -- -- -- 5.E /FXD 1,3/05.AS703 4,6,12
A003 CRAWL SPACE NO ACCESS - CRAWLSPACE 3' 2-1/2" X 2' 3" 15" -- -- -- -- MTL SCRN -- NO EXTG WINDOW OR FRAME -- 5.E /FXD 1,3/05.AS703 6,12
A004 CRAWL SPACE NO ACCESS - CRAWLSPACE 3' 2-1/2" X 2' 2-3/4" 15" HOP -- -- -- MTL SCRN -- -- -- 5.E /FXD 1,3/05.AS703 4,6,12
A005 CRAWL SPACE NO ACCESS - CRAWLSPACE 3' 2-1/2" X 2' 2-3/4" 15" HOP -- -- -- MTL SCRN -- -- -- 5.E /FXD 1,3/05.AS703 4,6,12
A006 CRAWL SPACE NO ACCESS - CRAWLSPACE 3' 2-1/2" X 2' 2-1/2" 15" HOP -- -- -- -- -- -- -- 5.E /HOP 2,3/05.AS703 4,6,12
A100 PATIENT DINING 100 10' 3" X 6' 8-1/2" 9' 11" X 7' 0-1/2" 15" DHX3 PAINT -- DW CLG 6" ABOVE R.O. -- -- WD BLINDS W/VALENCE, PARTITION WALL 2" FROM R.O., PARTITION WALL HAS WC AND
PICTURE RAIL
5.A / SH 5,6/05.AS703 1,6,10,15,20
A101 PATIENT DINING 100 10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW CLG 6" ABOVE R.O. -- -- WD BLINDS W/VALENCE, PARTITION WALL @ R.O., PARTITION WALL HAS WC &
PICTURE RAIL
5.A / SH 5,6/05.AS703 1,6,10,15,20
A102 CHIEFS OFFICE
100H
10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW POCKET AROUND R.O. -- Y BLINDS -- 5.A / SH 5,6/05.AS703 &
3/AS1101
1,6,10,15,20
A103 CANTEEN OFFICE
100H
10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW POCKET AROUND R.O. FULL SCREEN @ EXT Y BLINDS -- 5.A / SH 5,6/05.AS703 &
3/AS1101
1,6,10,12,15,20
A104 PATIENT DINING 100 10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW CLG 1/2" ABOVE R.O. -- -- WD BLINDS W/VALENCE, PARTITION WALL 1" FROM R.O.
-- 5.A / SH 5,6/05.AS703 1,6,10,15,20
A105 PATIENT DINING 100 10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/4" 15" DHX3 PAINT -- DW CLG 1/2" ABOVE R.O. -- -- WD BLINDS W/VALENCE -- 5.A / SH 5,6/05.AS703 1,6,10,15,20
A106 PATIENT DINING 100 10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW CLG 1/2" ABOVE R.O. -- -- WD BLINDS W/VALENCE -- 5.A / SH 5,6/05.AS703 1,6,10,15,20
A107 PATIENT DINING 100 10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW CLG 1/2" ABOVE R.O. -- -- WD BLINDS W/VALENCE -- 5.A / SH 5,6/05.AS703 1,6,10,15,20
A108 PATIENT DINING 100 10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW CLG 1/2" ABOVE R.O. -- -- WD BLINDS W/VALENCE -- 5.A / SH 5,6/05.AS703 1,6,10,15,20
A109 PATIENT DINING 100 10' 3" X 6' 8-1/2" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW CLG 1/2" ABOVE R.O. -- -- WD BLINDS W/VALENCE -- 5.A / SH 5,6/05.AS703 1,6,10,15,20
A110 PATIENT DINING 100 10' 3" X 6' 8-3/4" 9' 11-1/4" X 7' 0-1/2" 15" DHX3 PAINT -- DW CLG 1/2" ABOVE R.O. -- -- WD BLINDS W/VALENCE -- 5.A / SH 5,6/05.AS703 1,6,10,15,20
A200 OFFICE 204 3'11-1/2" X 5'6-1/2" 3' 8" x 5' 6" -- DH WC -- DW POCKET AROUND R.O. -- Y BLINDS OUTLET @ R.O. 5.C / SH 4,5/05.AS703
&3/AS1101
1,6,10,20
A201 OFFICE 203 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- DW @ R.O. -- Y - 25-1/2" X 17-1/2"
SHADE -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
A202 OFFICE 203 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- DW @ R.O. -- Y - 25-1/2" X 17-1/2"
SHADE -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
A203 OFFICE 202 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 WC -- DC @ R.O. -- -- SHADE -- 5.B / SH 5,6/05.AS703 1,6,10,15,20
A204 CONFERENCE ROOM
6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 WC -- DC CUTS OFF R.O. -- Y - 23-1/2" X 15" SHADE OUTLET @ 5"
FROM R.O.
5.B / SH 5,6/05.AS703 &
3,4,5/AS1101
1,6,10,14,17,15,2
A205 CONFERENCE ROOM
6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 WC -- DC CUTS OFF R.O. -- Y - 25-1/2" X
17-1/2"
SHADE OUTLET @ 6"
FROM R.O.
5.B / SH 5,6/05.AS703 &
3,4,5/AS1101
1,6,10,14,17,15,2
A206 OFFICE 200 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- DC @ R.O. -- -- BLINDS -- 5.B / SH 5,6/05.AS703 1,6,10,15,20
A207 OFFICE 226 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- CLEAR -- Y - 26" X 16" BLINDS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
A208 OFFICE 224 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- CLEAR -- Y - 25-3/4" X 17-1/2"
BLINDS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
A209 OFFICE 223 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- DC 1"-2" ABV R.O. -- Y - 25-3/4" X 17-1/2"
BLINDS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
A210 BREAK ROOM 222 6' 3" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- DC 1" ABV R.O. -- -- -- -- 5.B / SH 5,6/05.AS703 1,6,10,20
A211 OFFICE 221 6' 3" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- CLEAR -- Y - 25-3/4" X 17-1/2"
BLINDS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
A212 OFFICE 220 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- CLEAR -- Y - 19-1/2" X 14" BLINDS -- 5.B / SH AS703 / 3,4 1,6,10,14,15,20
A213 OFFICE 219 3' 7-1/4" X 5' 2-1/2" 3' 8" x 5' 6" 19-1/2" DH PAINT DW, 10-1/2" DEEP DC CUTS OFF R.O. -- BLINDS, FURRED WALL OUTLET @ 3-1/2"
FROM R.O.
5.C / SH 5,6/05.AS703 &
4,5/AS1101
1,6,10,15,17,20
A300 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
A301 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
A302 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
A303 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
A304 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
A305 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
B001 CRAWL SPACE LOCKED DOOR -- 15" -- -- -- -- -- -- -- -- 5.E / HOP 2,3/05.AS703 4,6
B002 STAIR S3 3'4-1/4" X 2'1" 3' 3" X 2' 15" HOP PAINT -- -- MTL SCRN @ INT -- -- -- 5.E / FXD 1,3/05.AS703 4,6,12
B003 STORAGE 001 3'4-1/4" X 2'1" 3' 3-1/4" X 2' 15" HOP PAINT/WD
PANELING
-- -- MTL SCRN @ INT -- -- -- 5.E / HOP 2,3/05.AS703 4,6,12
B004 STORAGE 001 3'4-1/4" X 2'1" 3' 3-1/4" X 2' 15" HOP PAINT/WD
PANELING
-- -- MTL SCRN @ INT -- -- -- 5.E / FXD 1,3/05.AS703 4,6
B005 MAIN
REFRIGERATION 004
LOUVER -- 15" -- -- -- -- -- -- -- -- -- -- --
B006 MAIN
REFRIGERATION 004
LOUVER -- 15" -- -- -- -- -- -- -- -- -- -- --
B007 TRANSFORMER
ROOM 004A
LOUVER -- -- -- -- -- -- -- -- -- -- -- -- --
B008 TRANSFORMER
ROOM 004A
LOUVER -- -- -- -- -- -- -- -- -- -- -- -- --
B009 CRAWL SPACE LOCKED DOOR -- -- -- -- -- -- -- -- -- -- 5.E / FXD 1,3/05.AS703 4,6
B010 CRAWL SPACE LOCKED DOOR -- -- -- -- -- -- -- -- -- -- 5.E / HOP 2,3/05.AS703 4,6
B100 PAPER STORAGE
PANEL & A/C 3' 2" X 4' 2" -- -- -- -- -- -- Y NO WINDOW -- 5.G / SH 4,5/05.AS703 &
3/AS1101
4,6,10,14,20
B101 PAPER STORAGE
LOUVER -- -- -- -- -- -- -- -- -- -- -- -- --
B102 CART WASH 112 3' 2-1/4" X 5' 3' 3-1/4" X 2' 8-1/2" TO B.O.
LOUVER
15" DH TILE (2
TYPES)
TILE CLEAR -- -- LOUVER @ TOP SASH ELEC CONDUIT
AND DUCTING
ADJACENT
5.H / SH 4,5/05.AS703 &
1,2/AS1101
5,10,20
B103 CART WASH 112 3' 2-1/4" X 5' 3' 3-1/4" X 5' 5-1/2" 15" DH TILE (2
TYPES)
TILE CLEAR -- -- LOUVER @ BOTTOM SASH ELEC CONDUIT
ADJACENT
5.I / SH 4,5/05.AS703 &
1,2/AS1101
5,10,20
B104 CHIEF 103D 3' 9" X 6' 11" to dw clg 3' 8" X 7' 15" DH PAINT DW DW @ R.O. -- -- WALLS FURRED IN 9" -- 5.C / SH 4,5/05.AS703 1,6,10,20
B105 CHIEF 103D 3' 9" X 6' 11" to dw clg 3' 8" X 7' 15" DH PAINT DW DW @ R.O. -- -- WALLS FURRED IN 9" -- 5.C / SH 4,5/05.AS703 1,6,10,20
B106 SECRETARY 103C 3' 9" X 3' 5" (TOP SASH R.O.) NO ACCESS 15" DH PAINT -- DW @ R.O. -- -- BLINDS, BOTTOM SASH INFILLED, TOP SASH ORIG WINDOW
-- 5.J / FXD 4,5/05.AS703 1,3,6,10,20,29
B107 SECRETARY 103C 3'9" X 6' 10" 3' 8" X 7' 15" DH PAINT -- DW @ R.O. -- -- BLINDS -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
B108 CLINICAL SECTION
CHIEF 103B
3'9" X 6' 10" 3' 8" X 7' 15" DH PAINT -- DW @ R.O. -- -- BLINDS -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
B109 TEMPORARY TRAY
LINE 103K
3'9" X 6' 11" 3' 8" X 7' 15" DH PAINT -- DW @ R.O. -- Y - 16-3/4" X 26" WD BLINDS -- 5.C / SH 4,5/05.AS703 &
3/AS1101
1,6,10,14,15,20
B110 TEMPORARY TRAY
LINE 103K
3'9" X 6' 11" 3' 8" X 7' 15" DH PAINT -- DW @ R.O. -- -- WD BLINDS -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
B111 TEMPORARY TRAY
LINE 103K
3'9" X 6' 11" 3' 8" X 7' 15" DH PAINT -- DW @ R.O. -- Y - 16-3/4" X 26" WD BLINDS -- 5.C / SH 4,5/05.AS703 &
3/AS1101
1,6,10,14,15,20
B112 TOILET 102 3' 8-3/4" X 6' 10-1/2" (to dw clg) 3' 8" X 7' 15" DH TILE, PAINT TILE DW @ R.O. -- -- TEXTURED GLASS (RR), WALL @ R.O.
-- 5.C / SH 4,5/05.AS703 1,6,10,15,20,23
B113 LOCKER ROOM
102A
3' 8-3/4" X 6' 10-1/2" (to clg) 3' 8" X 7' 15" DH TILE, PAINT TILE DW @ R.O. -- -- TEXTURED GLASS (RR) -- 5.C / SH 4,5/05.AS703 1,6,10,15,20,23
B114 SUPERVISOR 101A 11' 3-1/2" X 5' 11' 7" X 5' 3-1/2" 15" DHX3 TILE, PAINT TILE DW 2" ABV R.O. -- BLINDS -- 5.A /SH 5,6/05.AS703 1,6,10,15,20
B115 STAIR S1 3' 11-1/2" X 6' 10-1/2" 3' 8" X 7' 0-1/2" 15" DH PAINT -- CLEAR -- -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,20
NOTE:
THE PROPOSED WORK WITHIN AND AROUND CERTAIN BUILDINGS MUST BE
SCHEDULED AND COORDINATED WITH THE VA. THE GENERAL CONTRACTOR SHALL
PROVIDE A COMPREHENSIVE SCHEDULE OF EACH WINDOW IN ACCORDANCE WITH
THE FOLLOWING.
WORK WITHIN AND AROUND BUILDING 5 EFFECTING KITCHEN OPERATIONS SHALL
OCCUR OUTSIDE OF NORMAL WORKING HOURS.
All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.netVIRIDIAN
ARCHITECTURAL DESIGN INC.
100% BID DOCUMENTS
1. DIMENSIONS ARE TO EDGE OF WALL OR TO FACE OF WALL UNLESS NOTED
OTHERWISE.
2. BUILDING DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY ALL
DIMENSIONS PRIOR TO BEGINNING OF CONSTRUCTION.
3. GENERAL CONTRACTOR TO COORDINATE ALL ASSOCIATED WORK WITH ALL
SUB-CONTRACTORS.
4. ALL MATERIALS IN DEMOLITION DETAILS INDICATED AS DASHED ARE TO BE
REMOVED, SEE DETAILS ON THE A700 SHEETS. THIS INCLUDES ALL FINISHES AND
MATERIALS NOT SPECIFICALLY CALLED OUT BUT PERTAINING TO THE INTENDED
SCOPE.
5. CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE SITE TO BECOME
FAMILIAR WITH THE EXISTING CONDITIONS. THESE DRAWINGS SHALL SERVE TO AID
THE CONTRACTOR IN THE EVALUATION OF THE EXTENT OF DEMOLITION : BUT SHALL
NOT BE HELD TO BE ALL INCLUSIVE.
6. CONTRACTORS SHALL FIELD INSPECT ALL DEMOLITION WORK PRIOR TO REMOVAL,
TO INSURE SUCH REMOVAL DOES NOT IMPAIR STRUCTURAL INTEGRITY OF THE
EXISTING BUILDING . IF THE INSPECTION INDICATES THAT THE STRUCTURAL
INTEGRITY MAY BE COMPROMISED, NOTIFY THE ARCHITECT / ENGINEER
IMMEDIATELY.
7. ALL CONTRACTORS ARE RESPONSIBLE FOR CLEANING SITE TO THE BEST OF THEIR
ABILITIES AT THE END OF EACH WORK DAY.
8. THE CONTRACTOR RESPONSIBLE FOR GENERAL DEMOLITION WORK SHALL
COORDINATE WITH THE ELECTRICAL CONTRACTOR, ALL NECESSARY DEMOLITION TO
OCCUR WHERE ELECTRICAL ACCESS WORK MUST TAKE PLACE.
UPON COMPLETION OF ACCESS WORK, THE GENERAL CONTRACTOR SHALL
REPAIR AND REFINISH ACCESS AREAS TO APPEAR AS THOUGH NO ACCESS
WORK HAD OCCURRED.
MATERIALS NECESSARY FOR THIS WORK SHALL BE COMPATIBLE WITH THE
EXISTING CONSTRUCTION AND FINISH MATERIALS AND COLORS SHALL BLEND IN
WITH THE SURROUNDING SURFACES.
CONTRACTORS SHALL COORDINATE ALL DEMOLITION AND RECONSTRUCTION
WORK WITH OTHER TRADES, TO BE ASSURED THAT WORK IN EITHER OF THESE
AREAS IS COMPLEMENTARY TO THE OTHER AND COMPLETE IN ALL RESPECTS.
9. WHERE ANCHORING DEVICES, ADHESIVES OR MASTICS OCCUR ON EXISTING
CONSTRUCTION THEY SHALL BE REMOVED FROM ALL SURFACES, REPAIRED AND
FINISHED TO MATCH ADJACENT SURFACES.
10. CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE
INSTALLATION OF NEW CONSTRUCTION, WHETHER OR NOT IT IS SPECIFICALLY
SHOWN OR NOTED IN THESE DOCUMENTS.
11. ALL CONTRACTORS TO VERIFY STAGING AND STORAGE LOCATIONS OF ALL
MATERIALS AND EQUIPMENT WITH OWNER PRIOR TO BEGINNING OF CONSTRUCTION.
12. THE GC SHALL TEMPORARILY RELOCATE FURNITURE WITHIN THE SPACE AS
NECESSARY TO COMPLETE THE WORK AND REINSTALL IN ITS ORIGINAL LOCATION.
THE VA WILL REMOVE OR OTHERWISE SECURE ALL PIH, PPI, AND PERSONAL
PROPRTY. COORDINATE WITH COR.
13. ALL CONTRACTORS RESPONSIBLE FOR ANY DAMAGES CAUSED BY THEM DURING
THE CONSTRUCTION PROCESS. IN THE EVENT OF ANY DAMAGES CONTRACTOR IS
TO CONTACT COR IMMEDIATELY; PRIOR TO THE END OF THE DAY OF
CONSTRUCTION.
14. FOR FURTHER INFORMATION WITH REGARD TO THE EXACT EXTENT OF DEMOLITION,
SEE THE CONSTRUCTION PLANS WHICH ILLUSTRATE THE ADJACENT NEW
CONSTRUCTION.
THESE NOTES APPLY TO ALL DEMOLITION DRAWINGS AND TO ALL CONTRACTORS AND / OR
SUBCONTRACTORS THAT WORK WITHIN THIS BUILDING.
1. REMOVE EXISTING WINDOW UNIT IN ITS ENTIRETY, INCLUDING ALUMINUM SASHES,
FRAMING, PANNING, AND TRIM. REMOVE ANY REMAINING WINDOW MATERIAL
FROM ALL PREVIOUS WINDOW UNITS INCLUDING, BUT NOT LIMITED TO, FRAMING,
FASTENERS, ANCHORS, STOOLS, APRONS, BLOCKING / BUCKS (WOOD AND / OR
METAL) , AND WEIGHTS. TAKE CARE NOT TO DISTURB INTERIOR PERIMETER
PLASTER WORK OR FINISHED DRYWALL ROUGH OPENING. STRUCTURAL ELEMENTS,
INCLUDING HEADERS, LINTELS, AND STRUCTURAL MULLIONS TO REMAIN IN PLACE.
CONCRETE OR MASONRY SILLS TO REMAIN IN PLACE. REMOVE ANY OTHER
MATERIAL PRESENT SO THAT ONLY THE WINDOW ROUGH OPENING, SILL, AND
INTERIOR PERIMETER PLASTER WORK OR FINISHED DRYWALL REMAIN. INSULATE
ANY WALL CAVITIES EXPOSED BY WINDOW REMOVAL. SEE DETAILS AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. REMOVE EXISTING ALUMINUM WINDOW IN ITS ENTIRETY, INCLUDING SASHES,
FRAMING, AND ANY OTHER WINDOW MATERIAL FROM PREVIOUS INSTALLATIONS,
SO THAT ONLY THE ROUGH MASONRY OPENING REMAINS. SEE DETAILS FOR
ADDITIONAL INFORMATION.
3. REMOVE WINDOW AND / OR WALL INFILL MATERIAL TO ROUGH OPENING
INCLUDING CLADDING, BRICK, STUDS, INSULATION, DRYWALL, WINDOWS, AND
ANY OTHER MATERIALS. SEE DETAILS FOR ADDITIONAL INFORMATION.
4. REMOVE INFILL PANEL OR DOOR PANEL AND ANY FRAMING MATERIAL FROM
WINDOW OPENING SO THAT ONLY A ROUGH MASONRY OPENING (WITH LENTIL)
REMAINS. SEE DETAILS FOR ADDITIONAL INFORMATION.
5. LOUVER, VENT, OR OTHER MECHANICAL DEVICE TO REMAIN IN OPENING.
TEMPORARILY DISCONNECT FROM MECHANICAL EQUIPMENT AND ELECTRICAL
SERVICE. TEMPORARILY SUPPORT FOR REMOVAL OF WINDOW ABOVE OR BELOW
IN SAME WINDOW OPENING. INSTALL NEW FRAMING SUPPORT FOR EQUIPMENT.
INSTALL NEW ALUMINUM DOUBLE-GLAZED INSULATED WINDOW IN REMAINING
OPENING. SEE WINDOW SCHEDULE AND DETAILS FOR ADDITIONAL INFORMATION.
6. PROVIDE AND INSTALL NEW DOUBLE-GLAZED INSULATED ALUMINUM WINDOW
UNIT. SIZE TO FIT INTO ROUGH OPENING. WINDOW TO OPERATE AS INDICATED ON
WINDOW SCHEDULE. SEE WINDOW SCHEDULE FOR APPROXIMATE DIMENSIONS
AND DETAILS. SEE SPECIFICATION FOR ADDITIONAL INFORMATION. CONTRACTOR
TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS.
7. PROVIDE AND INSTALL BLAST RESISTANT WINDOW FILM ON ALL SASHES OF THIS
WINDOW UNIT. PRODUCT BASIS OF DESIGN: 3M ULTRA 800 OR EQUAL
APPROVED BY THE VA. SEE SPECIFICATION FOR ADDITIONAL INFORMATION.
8. RELOCATE ELECTRICAL OUTLET AND REROUTE IN-WALL CONDUIT FROM J-BOX OR
PANEL TO NEW ADJACENT LOCATION OUTSIDE AREA OF WINDOW REPLACEMENT.
9. ADJUST INTERIOR HVAC DUCTING SO THAT VENT OCCURS AT TOP SASH.
10. PROVIDE AND INSTALL NEW 1/2" THICK SOLID SURFACE WINDOW STOOL. SEE
FINISH SCHEDULE, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
11. PROVIDE AND INSTALL NEW SECURITY SCREEN AT WINDOW INTERIOR TO REPLACE
EXISTING. NEW SECURITY SCREEN SHALL CONFORM TO VA SECURITY DESIGN
GUIDE. SECURITY SCREEN SHALL REMAIN FUNCTIONAL EXCEPT WHEN BEING
REPLACED. CONTRACTOR SHALL REMOVE AND REPLACE SECURITY SCREEN
DURING WORKING HOURS. WINDOW SHALL NOT BE LEFT UNSECURED AT ANY
TIME.
12. REMOVE SECURITY SCREEN AND ALL ASSOCIATED HARDWARE FROM EXTERIOR
OR INTERIOR OF WINDOW. TEMPORARILY CATALOGUE AND STORE FOR
REINSTALLATION. CLEAN, REFINISH, AND REINSTALL AT SAME LOCATION AFTER
CORRESPONDING WINDOW HAS BEEN INSTALLED. PROVIDE ANY ADDITIONAL TRIM
AND HARDWARE REQUIRED FOR COMPLETE AND SECURE INSTALLATION.
13. PROVIDE AND INSTALL NEW EXTERIOR SECURITY SCREEN TO MATCH ADJACENT.
FINISH TO MATCH ADJACENT.
14. REMOVE AND TURN WINDOW AIR CONDITIONING UNIT (AC) OVER TO VA
MECHANICAL MAINTENANCE SHOP DURING CONSTRUCTION, COORDINATE WITH
COR. CLEAN AC UNIT (INTERIOR AND EXTERIOR), AND REINSTALL FOLLOWING
CORRESPONDING WINDOW REPLACEMENT WITH COMMERCIAL GRADE MOUNTING
BRACKET, GASKETS, 1" INSULATED PANEL, WEATHERPROOFING, FASTENERS, AND
OTHER MATERIALS AS SHOWN IN AC MOUNTING DETAIL 3/AS1101. INSTALL
EXISTING AC UNIT AND CAULK AROUND ALL EDGES TO ELIMINATE AIR INFILTRATION
THROUGH WINDOW OPENING. COORDINATE WITH COR.
15. REMOVE ALL BLINDS, CURTAINS, SHADES, AND ASSOCIATED HARDWARE IN THEIR
ENTIRETY. PROVIDE AND INSTALL NEW 1" ALUMINUM HORIZONTAL BLINDS AND
CORRESPONDING HARDWARE. SEE SPECIFICATION FOR ADDITIONAL
INFORMATION.
16. RELOCATE SURFACE MOUNTED ELECTRICAL OUTLET AND SURFACE CONDUIT TO
ADJACENT LOCATION OUTSIDE OF AREA OF WINDOW REPLACEMENT. REWIRE AS
NEEDED FROM J-BOX OR PANEL.
17. CAREFULLY REMOVE DRYWALL OR PLASTER CEILING OR BULKHEAD AS NEEDED
FOR REMOVAL OF WINDOW MATERIAL. CONSTRUCT NEW DRYWALL AND LIGHT
GAUGE STEEL FRAMING POCKET/ BULKHEAD AT CEILING AROUND NEW WINDOW
OPENING. SEE SPECIFICATIONS AND DETAILS 4&5 / AS1101 FOR ADDITIONAL
INFORMATION.
18. CAREFULLY REMOVE PORTION OF WALL AS NECESSARY FOR REMOVAL OF
WINDOW MATERIAL. PATCH AND REPAIR TO MATCH ADJACENT AFTER NEW
WINDOW INSTALLATION.
19. CAREFULLY REMOVE PORTION OF SUSPENDED ACOUSTICAL TILE CEILING AS
NEEDED FOR REMOVAL OF WINDOW MATERIAL. CONSTRUCT NEW DRYWALL AND
LIGHT GAUGE STEEL FRAMING POCKET/ BULKHEAD AT CEILING AROUND NEW
WINDOW OPENING. REPAIR SUSPENDED ACOUSTICAL TILE CEILING AROUND NEW
POCKET/BULKHEAD SO THAT NO GAPS IN THE CEILING REMAIN. SEE
SPECIFICATIONS AND DETAILS 6&7 / AS1101 FOR ADDITIONAL INFORMATION.
20. REPAIR AND RESTORE DRYWALL / PLASTER WALL SURFACES ADJACENT TO
WINDOW OPENING AND REFINISH (PAINT OR WALL COVERING) TO MATCH
ADJACENT.
21. CLEAN ALL ADHESIVES, DEBRIS, CAULKING, OR OTHER MATERIALS FROM
MASONRY OPENING. REFINISH TO MATCH ADJACENT MASONRY WALL.
22. REMOVE SPEAKER WIRING / CONDUIT RUNNING THROUGH EXISTING WINDOW
FRAME. CAP AT INTERIOR FOR FUTURE USE.
23. 1" INSULATED WINDOW GLASS TO BE FROSTED AT UPPER AND LOWER SASHES.
24. 1" INSULATED WINDOW GLASS TO BE FROSTED AT LOWER SASH ONLY.
25. 1" INSULATED WINDOW GLASS TO BE WIRE SAFETY GLASS.
26. REMOVE EXISTING LIGHT FIXTURE AT WINDOW OPENING IN ITS ENTIRETY. CAP
ELECTRICAL. PATCH AND REFINISH CEILING / BULKHEAD TO MATCH ADJACENT.
27. DO NOT DISTURB EXISTING WALL INFILL. ALL WINDOW REPLACEMENT WORK TO BE
PERFORMED FROM THE EXTERIOR FOR HUNG UNITS COVERED BY AN INTERIOR
WALL, LOCK SASHES IN PLACE AND SEAL AROUND ALL EDGES OF OPERABLE
SASH, INTERIOR AND EXTERIOR. SEE DETAILS 1&2 / AS1101.
28. TEMPORARILY REMOVE, CATALOGUE, AND STORE EXISTING BLACKOUT SHADE
AND ALL CORRESPONDING HARDWARE INCLUDING CEILING POCKETS, BLACKOUT
CHANNELS, AND MOUNTING DEVICES. CLEAN AND REINSTALL FOLLOWING
CORRESPONDING WINDOW REPLACEMENT. PROVIDE AND INSTALL ANY
ADDITIONAL HARDWARE REQUIRED FOR SECURE LIGHT-BLOCKING INSTALLATION.
SEE SPECIFICATION FOR ADDITIONAL INFORMATION.
29. INFILL REMAINING ROUGH OPENING TO MATCH ADJACENT WALL CONSTRUCTION.
30. PROVIDE FROSTED GLASS AT RESTROOM HALF OF WINDOW ONLY.
31. PROVIDE DOOR AT HALF OF WINDOW OPENING AS INDICATED ON THE ELEVATION
AND DETAIL DRAWINGS.
32. PROVIDE NEW DECORATIVE DOUBLE-GLAZED INSULATED ALUMINUM WINDOW
WITH APPLIED MUNTINS. SEE WINDOW SCHEDULE FOR ADDITIONAL INFORMATION
AND DETAILS.
33. 1" INSULATED GLASS TO BE COLORED AT TOP PANE. COLOR TO MATCH EXISTING.
34. REMOVE CONDUIT ADJACENT TO WINDOW. RELOCATE SO NOT TO INTERFERE
WITH WINDOW OPENING.
35. INSULATED INFILL PANEL TO BE GLAZED INTO WINDOW SASH INDICATED IN
DRAWING. CUT OPENING IN INFILL PANEL AS NEED FOR RE-INSTALLATION OF
MECHANICAL EQUIPMENT, LOUVER, OR VENT. RECONNECT EQUIPMENT, LOUVER,
OR VENT AT THE INTERIOR AND ALIGN WITH ALL EXISTING ADJACENT DUCTWORK
OR OTHER MECHANICAL EQUIPMENT.
36. INTERIOR METAL SECURITY SCREEN TO BE REPLACED. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
37. CONTRACTOR TO PROTECT FLOOR. COORDINATE WITH COR.
SH SINGLE HUNG
DH DOUBLE HUNG
FXD FIXED
CASE CASEMENT
HOP HOPPER
AWN AWNING
SL SLIDER
HS HORIZONTAL SLIDER
ALS ALUMINUM STOREFRONT
DC DROPPED CEILING (ACT)
ACT ACOUSTICAL TILE CEILING
DW DRYWALL / PLASTER
RO ROUGH OPENING
BO BOTTOM OF
TO TOP OF
WC WALL COVERING
VWC VINYL WALL COVERING
WD WOOD
SCRN SCREEN
MTL METAL
SS SOLID SURFACE
CT CERAMIC TILE
VIF VERIFY IN FIELD
NOTE:
ASBESTOS ABATEMENT: THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL
CONFIRMATION TESTING AND ABATEMENT OF HAZARDOUS MATERIALS IN
RENOVATION AREAS. SEE SPECIFICATIONS, EXISTING ASBESTOS SURVEY, AND ACM
TABLE ON SHEET GI004 FOR ADDITIONAL INFORMATION. COORDINATE WITH COR.
NOTE:
LEAD CONTAINING PAINT SUSPECTED IN ALL BUILDINGS. CONTRACTOR IS
RESPONSIBLE FOR ALL TESTING AND ABATEMENT OF LEAD PAINT.
NOTE:
CONTRACTOR TO REMOVE ALL RUST IN ITS ENTIRETY FROM STEEL LINTELS AND
PRIME AND PAINT WHITE TO MATCH NEW WINDOW. SEE SPECIFICATIONS FOR
ADDITION INFORMATION.
NOTE:
WINDOW DRAWINGS DO NOT REPRESENT A SPECIFIC PRODUCT OR MANUFACTURER.
THEY INTEND TO DESCRIBE WINDOW TYPES, GENERAL FEATURES, AND GENERAL
INSTALLATION REQUIREMENTS. ALL MEASUREMENTS AND EXISTING CONDITIONS
MUST BE VERIFIED IN FIELD BY THE CONTRACTOR. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
NOTE:
WINDOW MUNTINS TO BE 7
8" WIDE AND LOCATED BETWEEN IGU GLASS LAYERS ONLY.
RESULTING "DIVIDED" LITES SHALL BE APPROX. 9"-12" WIDE. SEE WINDOW
ELEVATIONS FOR GUIDANCE. ALL WINDOW MUNTIN DIMENSIONS AND LOCATIONS TO
BE INDICATED IN SHOP DRAWINGS FOR REVIEW BY THE VA AND ARCHITECT.
NOTE:
NOT ALL WINDOW REPLACEMENT NOTES APPEAR ON THIS SHEET.
NOTE:
ALL WINDOW FRAME DEPTHS TO MATCH EXISTING.
BUILDING 5 EXISTING WINDOW CONDITIONS REPLACEMENT WINDOWS
ROOM INTERIOR ROUGH OPENING EXTERIOR ROUGH OPENING WALL THICKNESS OPERATION FINISHES SILL SIZE & TYPE CEILING CONDITION SECURTIY SCREEN A/C OPENING ADDITIONAL COMMENTS ELECTRICAL ELEVATION /
OPERATION
DEMO DETAILS REMARKS
B200 STAIR S1 3' 11-1/2" X 5' 6-1/2" 3'8" X 5'6" 15" DH PAINT -- CLEAR -- -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,20
B201 CORRIDOR 3' 11-1/2" X 5' 6-1/2" 3'8" X 5'6" 15" DH PAINT -- DW 2" ABV R.O. -- -- SHADE -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
B202 OFFICE 204 3'7" X 5'7-1/2" 3'8" X 5'6" -- DH WC -- DW @ R.O. -- -- BLINDS, WALL FURRED IN -- 5.C / SH 4,5/05.AS703 1,6,10,20
B300 IT IT PANEL COVERING WINDOW -- -- DH -- -- -- -- -- NO INTERIOR ACCESS -- 5.C / SH 4,5/05.AS703 1,6,10,20
C001 CRAWL SPACE 005 LOUVER -- -- -- -- -- -- -- -- -- -- -- -- --
C002 STORAGE 001 3'4-1/4" X 2'1" 3' 3-1/4" X 2' 15" HOP PAINT/WD
PANELING
-- -- MTL SCRN @ INT -- PIPE IN FRONT OF R.O. -- 5.E / FXD 1,3/05.AS703 4,6,20
C100 TOILET 100D/
PATIENT DINING 100
6'3-1/2" X 6'10-1/2" 6' X 7' 0-1/2" 15" DHX2 PAINT, TILE DW, TILE DW @ R.O. -- -- PARITION WALL @ CTR WINDOW
MULLION
-- 5.B / SH 5,6/05.AS703 1,6,10,18,20,30
C101 DISH WASHING
AREA 101E
6' 4-1/2" X 5' 9-1/4" 6' 7" X 6' 2-1/4" 15" DHX2 FRP FRP, 5-3/4" DW @ R.O. -- -- SILL ANGLED TO WINDOW -- 5.B /SH 5,6/05.AS703 1,6,10,20
C102 CHIEF 103D 3' 4" X 5' 4-1/2" 3' 3-1/2" X 5' 5-1/2" FURRED DH PAINT DW, 9" DEEP DW @ R.O. -- Y - 19-1/2" X 14" FURRED WALL, BLINDS -- 5.C / SH 4,5/05.AS703 &
3/AS1101
1,6,10,14,15,17,2
C200 OFFICE 218 6'4-1/8" X 5'6-1/4" 6' X 5'6" 15" DHX2 PAINT -- CLEAR -- N BLINDS, TEXTURED GLASS @
LOWER SASH
-- 5.B / SH 5,6/05.AS703 1,6,10,20
C201 OFFICE 217 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- CLEAR -- Y - 25-1/2" x 17-1/2" BLINDS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
C202 OFFICE 216 6'3-1/2" X 5'6-1/2" 6' X 5'6" 15" DHX2 PAINT -- CLEAR -- Y - 19-1/2" x 14" SHADES OUTLET 1" FROM R. O.
5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
C203 OFFICE 215 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- CLEAR -- Y - 25-1/2" x 17-1/2" BLINDS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
C204 OFFICE 214 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 WC -- DW 1-2" ABV R.O. -- Y - 25-1/2" x 17-1/2" BLINDS, CURTAINS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
C205 OFFICE 212 3' 11" (=1/2 R.O.) 15" DH PAINT -- DW 1-2" ABV R.O. -- Y FROSTED GLASS, BLINDS OUTLET 6" FROM R.O.
5.C / SH 4,5/05.AS703 1,6,10,14,15,20,2
C206 TOILET 211 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" COMM STL DR &
DH
PAINT -- CLEAR -- -- TEXTURED GLASS (RR), DOOR
W/N 1/2" OF WINDOW FRAME
-- 5.K / DBL COMM
STL DR
5,6/05.AS703 1,6,10,20,23,31
C207 TOILET 209 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- DW 1-2" ABV R.O. -- -- TEXTURED GLASS (RR) -- 5.B / SH 5,6/05.AS703 1,6,10,20,23
C208 OFFICE 208 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 WC -- DC @ R.O. -- Y - 19-1/2" x 14" BLINDS OUTLET 7" FROM R.O.
5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
C209 OFFICE 207 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 WC -- DC @ R.O. -- Y - 25-1/2" x 17-1/2" BLINDS, CURTAINS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
C210 OFFICE 207 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 WC -- DC @ R.O. -- -- BLINDS -- 5.B / SH 5,6/05.AS703 1,6,10,15,20
C211 OFFICE 206 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 WC -- DW @ R.O. -- Y - 25-1/2" x 17-1/2" BLINDS, CURTAINS -- 5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
C212 OFFICE 205 6' 3-1/2" X 5' 6-1/2" 6' X 5'6" 15" DHX2 PAINT -- DW @ R.O. -- Y - 25-1/2" x 17-1/2" BLINDS, INWARD ANGLED WALL @ R.O.
OUTLET W/N 4"
FROM R.O.
5.B / SH 5,6/05.AS703 &
3/AS1101
1,6,10,14,15,20
C300 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
C301 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
C302 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- LOUVER -- -- -- --
C303 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- WINDOW/VENT -- 5.F / SH 4,5/05.AS703 &
1,2/AS1101
1,6,10,20
C304 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- LOUVER -- -- -- --
C305 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
C306 ATTIC 4'8-3/4" X 2'10-1/4" -- -- DH -- -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
D001 PIPE TUNNEL NO ACCESS 3' 2-1/2" X 2' 2-1/2" 15" -- -- -- -- MTL SCRN -- -- -- 5.E / FXD 1,3/05.AS703 4,6,12,20
D002 CRAWL SPACE 005 STAIRWELL, NO WINDOW -- -- -- -- -- -- -- -- -- -- -- -- --
D003 PIPE TUNNEL LOCKED DOOR -- -- -- -- -- -- -- -- -- -- 5.E / FXD 1,3/05.AS703 4,6,20
D004 PIPE TUNNEL R.O. ONLY, NO WINDOW -- -- -- -- -- -- -- CONDUIT RUNS THROUGH -- 5.E / HOP 2,3/05.AS703 4,6,20
D100 STAIR S2 3' 11-1/2" X 6' 10-1/2" 3' 8" X 7' 1" 15" DH PAINT -- CLEAR -- -- HANDRAIL OVERLAPS R.O. -- 5.C / SH 4,5/05.AS703 1,6,10,20
D101 DISHWASHING AREA
101E
3'6-1/4" X 5' 9-1/4" 3' 8" X 7' 1" 15" DH FRP -- DW @ R.O. -- -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,20
D102 DISHWASHING AREA
101E
3'6-1/4" X 5' 9-1/4" 3' 8" X 7' 1" 15" DH FRP -- DW @ R.O. -- -- VENT TOP SASH ELEC CONDUIT AT
VENT
5.F / SH 4,5/05.AS703 &
1,2/AS1101
5,10,20
D103 DISHWASHING AREA
101E
3'6-1/4" X 5' 9-1/4" 3' 8-1/4" X 6' 2-1/4" 15" DH FRP -- DW @ R.O. -- -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,20
D104 DISHWASHING AREA
101E
3'6-1/4" X 5' 9-1/4" 3' 8" X 5' 11" 15" DH FRP FRP, 6-1/4" DEEP -- -- -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,20
D105 FOOD BANK
REFRIGERATOR
101D
NO ACCESS 3'8" X 3' 3-1/2" (TO BOTTOM OF
VENT)
15" DH -- -- -- -- -- BLOCKED BY COOLER AT
INTERIOR-ALL WORK TO BE
COMPLETED FROM EXT.
-- 5.F / SH 4,5/05.AS703 &
1,2/AS1101
5,10,20,27
D106 FOOD BANK
REFRIGERATOR
101D
NO ACCESS 3' 8" X 6' 5" 15" DH -- -- -- -- -- BLOCKED BY COOLER AT
INTERIOR-ALL WORK TO BE
COMPLETED FROM EXT.
-- 5.C / SH 4,5/05.AS703 1,6,10,20,27
D107 FOOD TRAY
ASSEMBLY 119
3'4" X 6' 3' 8" X 6' 5" 15" DH FRP FRP, 6-1/4" DEEP CLEAR -- Y - 26" X 16-1/2" -- -- 5.C / SH 4,5/05.AS703 &
3/AS1101
1,6,10,14,20
D108 FOOD TRAY
ASSEMBLY 119
3'4" X 6' 3' 8" X 6' 5" 15" DH FRP CLEAR -- -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,20
D109 FOOD TRAY
ASSEMBLY 119
3'4" X 6' 3' 8" X 6' 5" 15" DH FRP CLEAR -- -- SHADE -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
D110 FOOD TRAY
ASSEMBLY 119
3'4" X 6' 3' 8" X 6' 5" 15" DH FRP CLEAR -- -- SHADE -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
D111 RECEIVING 118 3' 11-1/2" X 5' 6-1/2" 3' 8" X 5' 3-1/2" 15" DH PAINT -- DW @ R.O. SCREEN @ INT -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,12,20
D112 STORAGE 118B 3' 11-1/2" X 5' 6-1/2" 3' 8" X 5' 3-1/2" 15" DH PAINT -- DW @ R.O. SCREEN @ INT -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,12,20
D113 STORAGE 118B 3' 11-1/2" X 5' 6-1/2" 3' 8" X 5' 3-1/2" 15" DH PAINT -- DW @ R.O. SCREEN @ INT -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,12,20
D114 STORAGE 118B 3' 11-1/2" X 5' 6-1/2" 3' 8" X 5' 3-1/2" 15" DH PAINT -- DW @ R.O. SCREEN @ INT -- -- -- 5.C / SH 4,5/05.AS703 1,6,10,12,20
D115 STORAGE 118B 3' 11-1/2" X 5' 6-1/2" 3' 8.5" X 5' 3-1/2" 15" DH PAINT -- DW @ R.O. SCREEN @ INT -- R.O. @ DW CHASE -- 5.C / SH 4,5/05.AS703 1,6,10,12,20
D116 STORAGE 118B 3' 11-1/2" X 5' 6-1/2" 3' 8" X 5' 3-1/2" 15" DH PAINT -- DW @ R.O. SCREEN @ INT -- R.O. @ DW CHASE -- 5.C / SH 4,5/05.AS703 1,6,10,12,20
D200 OFFICE 219 3' 7" X 5' 3" (TO DW CLG) 3' 8" x 5' 6" 19-1/2" DH PAINT DW, 10-1/2" DEEP DC CUTS OFF R.O. -- -- BLINDS, FURRED WALL -- 5.C / SH 4,5/05.AS703 &
4,5/AS1101
1,6,10,15,17,20
D201 CORRIDOR 3' 11-1/2" X 5' 6-1/2" 3' 8" x 5' 6" 15" DH PAINT -- CLEAR -- -- SHADE -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
D202 STAIR S2 3' 11-1/2" X 5' 6-1/2" 3' 8" x 5' 6" 15" DH PAINT -- DC 1"-2" ABV R.O. -- -- SHADE -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
D300 ATTIC 3'5" X 4'10" -- -- -- BRICK -- -- -- -- -- -- 5.D / SH 4,5/05.AS703 1,6,10,20
E101 C15 6' 2-1/2" X 5' 5-1/2" NO ACCESS -- DHX2 FRP, PAINT -- ACT CLG CUTS OFF R.O. -- -- -- 5.B / SH 5,6/05.AS703 1,6,10,19,20
F101 SUPERVISORS 105 3'6" X 5'5" NO ACCESS 15" DH FRP FRP ACT CLG CUTS OFF R.O. -- -- -- -- 5.C / SH 4,5/05.AS703 &
6,7/AS1101
1,6,10,19,20
F102 SUPERVISORS 105 3'6" X 5'5" NO ACCESS 15" DH FRP FRP ACT CLG CUTS OFF R.O. -- -- -- -- 5.C / SH 4,5/05.AS703 &
6,7/AS1101
1,6,10,19,20
G101 CLERKS 106 2'10" X 3'11" NO ACCESS 10" DH PAINT STEEL, 1-1/2" DEEP DC 1" ABV R.O. -- -- BLINDS, ORIG STEEL FRAME -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
G102 CLERKS 106 2'10" X 3'11" NO ACCESS 10" DH PAINT STEEL, 1-1/2" DEEP DC 1" ABV R.O. -- -- BLINDS, ORIG STEEL FRAME -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
G103 CLERKS 106 2'10" X 3'11" NO ACCESS 10" DH PAINT STEEL, 1-1/2" DEEP DC 1" ABV R.O. -- -- BLINDS, ORIG STEEL FRAME OUTLET 6" FROM R.O.
5.C / SH 4,5/05.AS703 1,6,10,15,20
H101 TEMP KITCHEN 103G 3' 11-1/4" X 6' 3-1/5" NO ACCESS -- DH PAINT, TILE TILE DW @ R.O. -- -- BLINDS -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
H102 TEMP KITCHEN 103G 3' 11-1/4" X 6' 3-1/5" NO ACCESS -- DH PAINT, TILE TILE DW @ R.O. -- -- BLINDS -- 5.C / SH 4,5/05.AS703 1,6,10,15,20
NOTE:
THE PROPOSED WORK WITHIN AND AROUND CERTAIN BUILDINGS MUST BE
SCHEDULED AND COORDINATED WITH THE VA. THE GENERAL CONTRACTOR SHALL
PROVIDE A COMPREHENSIVE SCHEDULE OF EACH WINDOW IN ACCORDANCE WITH
THE FOLLOWING.
WORK WITHIN AND AROUND BUILDING 5 EFFECTING KITCHEN OPERATIONS SHALL
OCCUR OUTSIDE OF NORMAL WORKING HOURS.
NOTE:
PROVIDE AND INSTALL A DOUBLE INSULATED STEEL DOUBLE DOOR IN OPENING
C206 ONLY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMAITON.
| 3 |
| 18 515-14-103.05-AS701 |
| Sheets and Views |
| AS701 |
| 19 515-14-103.05-AS702 |
| Sheets and Views |
| AS702 |
| 20 515-14-103.05-AS703 |
| Sheets and Views |
| AS703 |
File details come from the government source that posted it.