36C25018B0823-005.pdf
PDF 13 MB Posted
- Attached to
- Replace Windows-Various Buildings 515-14-103 Federal contract opportunity
- Solicitation number
- 36C25018B0823
About this file
36C25018B0823 S02 - Drawings - 515-14-103_Part3.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25018B0823-0001000.docx | DOCX document | |
| 36C25018B0823-0001001.pdf | ||
| 36C25018B0823-002.pdf | ||
| 36C25018B0823-003.pdf | ||
| 36C25018B0823-013.pdf | ||
| 36C25018B0823-011.pdf | ||
| 36C25018B0823-018.docx | DOCX document | |
| 36C25018B0823-019.pdf | ||
| 36C25018B0823-001.docx | DOCX document | |
| 36C25018B0823-008.pdf | ||
| 36C25018B0823-015.pdf | ||
| 36C25018B0823-006.pdf | ||
| 36C25018B0823-017.pdf | ||
| 36C25018B0823-012.pdf | ||
| 36C25018B0823-010.pdf | ||
| 36C25018B0823-016.pdf | ||
| 36C25018B0823-007.pdf | ||
| 36C25018B0823-014.pdf | ||
| 36C25018B0823-009.pdf | ||
| 36C25018B0823-004.pdf | ||
| 36C25018B0823-000.docx | DOCX document |
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.netVIRIDIAN
ARCHITECTURAL DESIGN INC.
100% BID DOCUMENTS
1. DIMENSIONS ARE TO EDGE OF WALL OR TO FACE OF WALL UNLESS NOTED
OTHERWISE.
2. BUILDING DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY ALL
DIMENSIONS PRIOR TO BEGINNING OF CONSTRUCTION.
3. GENERAL CONTRACTOR TO COORDINATE ALL ASSOCIATED WORK WITH ALL
SUB-CONTRACTORS.
4. ALL MATERIALS IN DEMOLITION DETAILS INDICATED AS DASHED ARE TO BE
REMOVED, SEE DETAILS ON THE A700 SHEETS. THIS INCLUDES ALL FINISHES AND
MATERIALS NOT SPECIFICALLY CALLED OUT BUT PERTAINING TO THE INTENDED
SCOPE.
5. CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE SITE TO BECOME
FAMILIAR WITH THE EXISTING CONDITIONS. THESE DRAWINGS SHALL SERVE TO AID
THE CONTRACTOR IN THE EVALUATION OF THE EXTENT OF DEMOLITION : BUT SHALL
NOT BE HELD TO BE ALL INCLUSIVE.
6. CONTRACTORS SHALL FIELD INSPECT ALL DEMOLITION WORK PRIOR TO REMOVAL,
TO INSURE SUCH REMOVAL DOES NOT IMPAIR STRUCTURAL INTEGRITY OF THE
EXISTING BUILDING . IF THE INSPECTION INDICATES THAT THE STRUCTURAL
INTEGRITY MAY BE COMPROMISED, NOTIFY THE ARCHITECT / ENGINEER
IMMEDIATELY.
7. ALL CONTRACTORS ARE RESPONSIBLE FOR CLEANING SITE TO THE BEST OF THEIR
ABILITIES AT THE END OF EACH WORK DAY.
8. THE CONTRACTOR RESPONSIBLE FOR GENERAL DEMOLITION WORK SHALL
COORDINATE WITH THE ELECTRICAL CONTRACTOR, ALL NECESSARY DEMOLITION TO
OCCUR WHERE ELECTRICAL ACCESS WORK MUST TAKE PLACE.
UPON COMPLETION OF ACCESS WORK, THE GENERAL CONTRACTOR SHALL
REPAIR AND REFINISH ACCESS AREAS TO APPEAR AS THOUGH NO ACCESS
WORK HAD OCCURRED.
MATERIALS NECESSARY FOR THIS WORK SHALL BE COMPATIBLE WITH THE
EXISTING CONSTRUCTION AND FINISH MATERIALS AND COLORS SHALL BLEND IN
WITH THE SURROUNDING SURFACES.
CONTRACTORS SHALL COORDINATE ALL DEMOLITION AND RECONSTRUCTION
WORK WITH OTHER TRADES, TO BE ASSURED THAT WORK IN EITHER OF THESE
AREAS IS COMPLEMENTARY TO THE OTHER AND COMPLETE IN ALL RESPECTS.
9. WHERE ANCHORING DEVICES, ADHESIVES OR MASTICS OCCUR ON EXISTING
CONSTRUCTION THEY SHALL BE REMOVED FROM ALL SURFACES, REPAIRED AND
FINISHED TO MATCH ADJACENT SURFACES.
10. CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE
INSTALLATION OF NEW CONSTRUCTION, WHETHER OR NOT IT IS SPECIFICALLY
SHOWN OR NOTED IN THESE DOCUMENTS.
11. ALL CONTRACTORS TO VERIFY STAGING AND STORAGE LOCATIONS OF ALL
MATERIALS AND EQUIPMENT WITH OWNER PRIOR TO BEGINNING OF CONSTRUCTION.
12. THE GC SHALL TEMPORARILY RELOCATE FURNITURE WITHIN THE SPACE AS
NECESSARY TO COMPLETE THE WORK AND REINSTALL IN ITS ORIGINAL LOCATION.
THE VA WILL REMOVE OR OTHERWISE SECURE ALL PIH, PPI, AND PERSONAL
PROPRTY. COORDINATE WITH COR.
13. ALL CONTRACTORS RESPONSIBLE FOR ANY DAMAGES CAUSED BY THEM DURING
THE CONSTRUCTION PROCESS. IN THE EVENT OF ANY DAMAGES CONTRACTOR IS
TO CONTACT COR IMMEDIATELY; PRIOR TO THE END OF THE DAY OF
CONSTRUCTION.
14. FOR FURTHER INFORMATION WITH REGARD TO THE EXACT EXTENT OF DEMOLITION,
SEE THE CONSTRUCTION PLANS WHICH ILLUSTRATE THE ADJACENT NEW
CONSTRUCTION.
THESE NOTES APPLY TO ALL DEMOLITION DRAWINGS AND TO ALL CONTRACTORS AND / OR
SUBCONTRACTORS THAT WORK WITHIN THIS BUILDING.
1. REMOVE EXISTING WINDOW UNIT IN ITS ENTIRETY, INCLUDING ALUMINUM SASHES,
FRAMING, PANNING, AND TRIM. REMOVE ANY REMAINING WINDOW MATERIAL
FROM ALL PREVIOUS WINDOW UNITS INCLUDING, BUT NOT LIMITED TO, FRAMING,
FASTENERS, ANCHORS, STOOLS, APRONS, BLOCKING / BUCKS (WOOD AND / OR
METAL) , AND WEIGHTS. TAKE CARE NOT TO DISTURB INTERIOR PERIMETER
PLASTER WORK OR FINISHED DRYWALL ROUGH OPENING. STRUCTURAL ELEMENTS,
INCLUDING HEADERS, LINTELS, AND STRUCTURAL MULLIONS TO REMAIN IN PLACE.
CONCRETE OR MASONRY SILLS TO REMAIN IN PLACE. REMOVE ANY OTHER
MATERIAL PRESENT SO THAT ONLY THE WINDOW ROUGH OPENING, SILL, AND
INTERIOR PERIMETER PLASTER WORK OR FINISHED DRYWALL REMAIN. INSULATE
ANY WALL CAVITIES EXPOSED BY WINDOW REMOVAL. SEE DETAILS AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. REMOVE EXISTING ALUMINUM WINDOW IN ITS ENTIRETY, INCLUDING SASHES,
FRAMING, AND ANY OTHER WINDOW MATERIAL FROM PREVIOUS INSTALLATIONS,
SO THAT ONLY THE ROUGH MASONRY OPENING REMAINS. SEE DETAILS FOR
ADDITIONAL INFORMATION.
3. REMOVE WINDOW AND / OR WALL INFILL MATERIAL TO ROUGH OPENING
INCLUDING CLADDING, BRICK, STUDS, INSULATION, DRYWALL, WINDOWS, AND
ANY OTHER MATERIALS. SEE DETAILS FOR ADDITIONAL INFORMATION.
4. REMOVE INFILL PANEL OR DOOR PANEL AND ANY FRAMING MATERIAL FROM
WINDOW OPENING SO THAT ONLY A ROUGH MASONRY OPENING (WITH LENTIL)
REMAINS. SEE DETAILS FOR ADDITIONAL INFORMATION.
5. LOUVER, VENT, OR OTHER MECHANICAL DEVICE TO REMAIN IN OPENING.
TEMPORARILY DISCONNECT FROM MECHANICAL EQUIPMENT AND ELECTRICAL
SERVICE. TEMPORARILY SUPPORT FOR REMOVAL OF WINDOW ABOVE OR BELOW
IN SAME WINDOW OPENING. INSTALL NEW FRAMING SUPPORT FOR EQUIPMENT.
INSTALL NEW ALUMINUM DOUBLE-GLAZED INSULATED WINDOW IN REMAINING
OPENING. SEE WINDOW SCHEDULE AND DETAILS FOR ADDITIONAL INFORMATION.
6. PROVIDE AND INSTALL NEW DOUBLE-GLAZED INSULATED ALUMINUM WINDOW
UNIT. SIZE TO FIT INTO ROUGH OPENING. WINDOW TO OPERATE AS INDICATED ON
WINDOW SCHEDULE. SEE WINDOW SCHEDULE FOR APPROXIMATE DIMENSIONS
AND DETAILS. SEE SPECIFICATION FOR ADDITIONAL INFORMATION. CONTRACTOR
TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS.
7. PROVIDE AND INSTALL BLAST RESISTANT WINDOW FILM ON ALL SASHES OF THIS
WINDOW UNIT. PRODUCT BASIS OF DESIGN: 3M ULTRA 800 OR EQUAL
APPROVED BY THE VA. SEE SPECIFICATION FOR ADDITIONAL INFORMATION.
8. RELOCATE ELECTRICAL OUTLET AND REROUTE IN-WALL CONDUIT FROM J-BOX OR
PANEL TO NEW ADJACENT LOCATION OUTSIDE AREA OF WINDOW REPLACEMENT.
9. ADJUST INTERIOR HVAC DUCTING SO THAT VENT OCCURS AT TOP SASH.
10. PROVIDE AND INSTALL NEW 1/2" THICK SOLID SURFACE WINDOW STOOL. SEE
FINISH SCHEDULE, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
11. PROVIDE AND INSTALL NEW SECURITY SCREEN AT WINDOW INTERIOR TO REPLACE
EXISTING. NEW SECURITY SCREEN SHALL CONFORM TO VA SECURITY DESIGN
GUIDE. SECURITY SCREEN SHALL REMAIN FUNCTIONAL EXCEPT WHEN BEING
REPLACED. CONTRACTOR SHALL REMOVE AND REPLACE SECURITY SCREEN
DURING WORKING HOURS. WINDOW SHALL NOT BE LEFT UNSECURED AT ANY
TIME.
12. REMOVE SECURITY SCREEN AND ALL ASSOCIATED HARDWARE FROM EXTERIOR
OR INTERIOR OF WINDOW. TEMPORARILY CATALOGUE AND STORE FOR
REINSTALLATION. CLEAN, REFINISH, AND REINSTALL AT SAME LOCATION AFTER
CORRESPONDING WINDOW HAS BEEN INSTALLED. PROVIDE ANY ADDITIONAL TRIM
AND HARDWARE REQUIRED FOR COMPLETE AND SECURE INSTALLATION.
13. PROVIDE AND INSTALL NEW EXTERIOR SECURITY SCREEN TO MATCH ADJACENT.
FINISH TO MATCH ADJACENT.
14. REMOVE AND TURN WINDOW AIR CONDITIONING UNIT (AC) OVER TO VA
MECHANICAL MAINTENANCE SHOP DURING CONSTRUCTION, COORDINATE WITH
COR. CLEAN AC UNIT (INTERIOR AND EXTERIOR), AND REINSTALL FOLLOWING
CORRESPONDING WINDOW REPLACEMENT WITH COMMERCIAL GRADE MOUNTING
BRACKET, GASKETS, 1" INSULATED PANEL, WEATHERPROOFING, FASTENERS, AND
OTHER MATERIALS AS SHOWN IN AC MOUNTING DETAIL 3/AS1101. INSTALL
EXISTING AC UNIT AND CAULK AROUND ALL EDGES TO ELIMINATE AIR INFILTRATION
THROUGH WINDOW OPENING. COORDINATE WITH COR.
15. REMOVE ALL BLINDS, CURTAINS, SHADES, AND ASSOCIATED HARDWARE IN THEIR
ENTIRETY. PROVIDE AND INSTALL NEW 1" ALUMINUM HORIZONTAL BLINDS AND
CORRESPONDING HARDWARE. SEE SPECIFICATION FOR ADDITIONAL
INFORMATION.
16. RELOCATE SURFACE MOUNTED ELECTRICAL OUTLET AND SURFACE CONDUIT TO
ADJACENT LOCATION OUTSIDE OF AREA OF WINDOW REPLACEMENT. REWIRE AS
NEEDED FROM J-BOX OR PANEL.
17. CAREFULLY REMOVE DRYWALL OR PLASTER CEILING OR BULKHEAD AS NEEDED
FOR REMOVAL OF WINDOW MATERIAL. CONSTRUCT NEW DRYWALL AND LIGHT
GAUGE STEEL FRAMING POCKET/ BULKHEAD AT CEILING AROUND NEW WINDOW
OPENING. SEE SPECIFICATIONS AND DETAILS 4&5 / AS1101 FOR ADDITIONAL
INFORMATION.
18. CAREFULLY REMOVE PORTION OF WALL AS NECESSARY FOR REMOVAL OF
WINDOW MATERIAL. PATCH AND REPAIR TO MATCH ADJACENT AFTER NEW
WINDOW INSTALLATION.
19. CAREFULLY REMOVE PORTION OF SUSPENDED ACOUSTICAL TILE CEILING AS
NEEDED FOR REMOVAL OF WINDOW MATERIAL. CONSTRUCT NEW DRYWALL AND
LIGHT GAUGE STEEL FRAMING POCKET/ BULKHEAD AT CEILING AROUND NEW
WINDOW OPENING. REPAIR SUSPENDED ACOUSTICAL TILE CEILING AROUND NEW
POCKET/BULKHEAD SO THAT NO GAPS IN THE CEILING REMAIN. SEE
SPECIFICATIONS AND DETAILS 6&7 / AS1101 FOR ADDITIONAL INFORMATION.
20. REPAIR AND RESTORE DRYWALL / PLASTER WALL SURFACES ADJACENT TO
WINDOW OPENING AND REFINISH (PAINT OR WALL COVERING) TO MATCH
ADJACENT.
21. CLEAN ALL ADHESIVES, DEBRIS, CAULKING, OR OTHER MATERIALS FROM
MASONRY OPENING. REFINISH TO MATCH ADJACENT MASONRY WALL.
22. REMOVE SPEAKER WIRING / CONDUIT RUNNING THROUGH EXISTING WINDOW
FRAME. CAP AT INTERIOR FOR FUTURE USE.
23. 1" INSULATED WINDOW GLASS TO BE FROSTED AT UPPER AND LOWER SASHES.
24. 1" INSULATED WINDOW GLASS TO BE FROSTED AT LOWER SASH ONLY.
25. 1" INSULATED WINDOW GLASS TO BE WIRE SAFETY GLASS.
26. REMOVE EXISTING LIGHT FIXTURE AT WINDOW OPENING IN ITS ENTIRETY. CAP
ELECTRICAL. PATCH AND REFINISH CEILING / BULKHEAD TO MATCH ADJACENT.
27. DO NOT DISTURB EXISTING WALL INFILL. ALL WINDOW REPLACEMENT WORK TO BE
PERFORMED FROM THE EXTERIOR FOR HUNG UNITS COVERED BY AN INTERIOR
WALL, LOCK SASHES IN PLACE AND SEAL AROUND ALL EDGES OF OPERABLE
SASH, INTERIOR AND EXTERIOR. SEE DETAILS 1&2 / AS1101.
28. TEMPORARILY REMOVE, CATALOGUE, AND STORE EXISTING BLACKOUT SHADE
AND ALL CORRESPONDING HARDWARE INCLUDING CEILING POCKETS, BLACKOUT
CHANNELS, AND MOUNTING DEVICES. CLEAN AND REINSTALL FOLLOWING
CORRESPONDING WINDOW REPLACEMENT. PROVIDE AND INSTALL ANY
ADDITIONAL HARDWARE REQUIRED FOR SECURE LIGHT-BLOCKING INSTALLATION.
SEE SPECIFICATION FOR ADDITIONAL INFORMATION.
29. INFILL REMAINING ROUGH OPENING TO MATCH ADJACENT WALL CONSTRUCTION.
30. PROVIDE FROSTED GLASS AT RESTROOM HALF OF WINDOW ONLY.
31. PROVIDE DOOR AT HALF OF WINDOW OPENING AS INDICATED ON THE ELEVATION
AND DETAIL DRAWINGS.
32. PROVIDE NEW DECORATIVE DOUBLE-GLAZED INSULATED ALUMINUM WINDOW
WITH APPLIED MUNTINS. SEE WINDOW SCHEDULE FOR ADDITIONAL INFORMATION
AND DETAILS.
33. 1" INSULATED GLASS TO BE COLORED AT TOP PANE. COLOR TO MATCH EXISTING.
34. REMOVE CONDUIT ADJACENT TO WINDOW. RELOCATE SO NOT TO INTERFERE
WITH WINDOW OPENING.
35. INSULATED INFILL PANEL TO BE GLAZED INTO WINDOW SASH INDICATED IN
DRAWING. CUT OPENING IN INFILL PANEL AS NEED FOR RE-INSTALLATION OF
MECHANICAL EQUIPMENT, LOUVER, OR VENT. RECONNECT EQUIPMENT, LOUVER,
OR VENT AT THE INTERIOR AND ALIGN WITH ALL EXISTING ADJACENT DUCTWORK
OR OTHER MECHANICAL EQUIPMENT.
36. INTERIOR METAL SECURITY SCREEN TO BE REPLACED. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
37. CONTRACTOR TO PROTECT FLOOR. COORDINATE WITH COR.
SH SINGLE HUNG
DH DOUBLE HUNG
FXD FIXED
CASE CASEMENT
HOP HOPPER
AWN AWNING
SL SLIDER
HS HORIZONTAL SLIDER
ALS ALUMINUM STOREFRONT
DC DROPPED CEILING (ACT)
ACT ACOUSTICAL TILE CEILING
DW DRYWALL / PLASTER
RO ROUGH OPENING
BO BOTTOM OF
TO TOP OF
WC WALL COVERING
VWC VINYL WALL COVERING
WD WOOD
SCRN SCREEN
MTL METAL
SS SOLID SURFACE
CT CERAMIC TILE
VIF VERIFY IN FIELD
NOTE:
ASBESTOS ABATEMENT: THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL
CONFIRMATION TESTING AND ABATEMENT OF HAZARDOUS MATERIALS IN
RENOVATION AREAS. SEE SPECIFICATIONS, EXISTING ASBESTOS SURVEY, AND ACM
TABLE ON SHEET GI004 FOR ADDITIONAL INFORMATION. COORDINATE WITH COR.
NOTE:
LEAD CONTAINING PAINT SUSPECTED IN ALL BUILDINGS. CONTRACTOR IS
RESPONSIBLE FOR ALL TESTING AND ABATEMENT OF LEAD PAINT.
NOTE:
CONTRACTOR TO REMOVE ALL RUST IN ITS ENTIRETY FROM STEEL LINTELS AND
PRIME AND PAINT WHITE TO MATCH NEW WINDOW. SEE SPECIFICATIONS FOR
ADDITION INFORMATION.
NOTE:
WINDOW DRAWINGS DO NOT REPRESENT A SPECIFIC PRODUCT OR MANUFACTURER.
THEY INTEND TO DESCRIBE WINDOW TYPES, GENERAL FEATURES, AND GENERAL
INSTALLATION REQUIREMENTS. ALL MEASUREMENTS AND EXISTING CONDITIONS
MUST BE VERIFIED IN FIELD BY THE CONTRACTOR. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
NOTE:
WINDOW MUNTINS TO BE 7
8" WIDE AND LOCATED BETWEEN IGU GLASS LAYERS ONLY.
RESULTING "DIVIDED" LITES SHALL BE APPROX. 9"-12" WIDE. SEE WINDOW
ELEVATIONS FOR GUIDANCE. ALL WINDOW MUNTIN DIMENSIONS AND LOCATIONS TO
BE INDICATED IN SHOP DRAWINGS FOR REVIEW BY THE VA AND ARCHITECT.
NOTE:
NOT ALL WINDOW REPLACEMENT NOTES APPEAR ON THIS SHEET.
NOTE:
ALL WINDOW FRAME DEPTHS TO MATCH EXISTING.
WINDOW SCHEDULE CONTINUED ON SHEET 01.AS702.
BUILDING 1 EXISTING WINDOW CONDITIONS REPLACEMENT WINDOWS
ROOM INTERIOR ROUGH OPENING EXTERIOR ROUGH OPENING WALL THICKNESS OPERATION FINISHES SILL SIZE & TYPE CEILING CONDITION SECURTIY SCREEN A/C OPENING ADDITIONAL COMMENTS ELECTRICAL ELEVATION /
OPERATION
DETAILS REMARKS
A001 OFFICE 002 3'3" X 4'2" 3'2" X 4'4" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- 18" x 14" BLINDS -- SH / 1.B 3,4/01.AS703 &
3/AS1101
1,6,10,14,15,20
A002 CONF RM 001 3'2" X 4'2" 3'2" X 4'4" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- 24" x 14" BLINDS, PIPE AT TOP OF WINDOW WELL OUTLET IN
BUILD OUT
SH / 1.B 3,4/01.AS703 &
3/AS1101
1,6,10,14,15,16, A003 CONF RM 001 3'2" X 4'2" 3'2" X 4'4" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- -- BLINDS -- SH / 1.B 3,4/01.AS703 1,6,10,15,20
A004 CONF RM 001 3'2" X 4'2" 3'2" X 4'4" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- 24" x 14" BLINDS, PIPE AT TOP OF WINDOW WELL -- SH / 1.B 3,4/01.AS703 &
3/AS1101
1,6,10,14,15,20
A005 CONF RM 001 3'2" X 4'2" 3'2" X 2'4" 8" (FURRED OUT 12"-15") HOP PAINT PAINT DW 1" ABV R.O. -- -- BLINDS, PIPE AT TOP OF WINDOW WELL -- HOP / 1.C 7,8/AS703 1,6,10,15,20
A006 OFFICE 015 3'1" X 2'2" 3'2" X 2'4" 8" (FURRED OUT 12"-15") HOP PAINT PAINT DW 1" ABV R.O. -- -- BLINDS, PIPE AT TOP OF WINDOW WELL -- HOP / 1.C 7,8/AS703 1,6,10,15,20
A007 OFFICE 014 3'1" X 2'0" 3'2" X 2'4" 8" (FURRED OUT 12"-15") HOP PAINT PAINT DW 1" ABV R.O. -- -- BLINDS, PIPE AT TOP OF WINDOW WELL -- HOP / 1.C 7,8/AS703 1,6,10,15,20
A008 OFFICE 013 3'1" X 2'0" 3'2" X 2'4" 8" (FURRED OUT 12"-15") HOP PAINT PAINT DW 1" ABV R.O. -- -- BLINDS, PIPE AT TOP OF WINDOW WELL -- HOP / 1.C 7,8/AS703 1,6,10,15,20
A009 OFFICE 013A 3'1" X 2'0" 3'2" X 2'4" 8" (FURRED OUT 12"-15") HOP PAINT PAINT DW 1" ABV R.O. -- -- BLINDS, PIPE AT TOP OF WINDOW WELL -- HOP / 1.C 7,8/AS703 1,6,10,15,20
A010 OFFICE 013A 3'1" X 2'0" 3'2" X 2'4" 8" (FURRED OUT 12"-15") HOP PAINT PAINT DW 1" ABV R.O. -- -- BLINDS, PIPE AT TOP OF WINDOW WELL -- HOP / 1.C 7,8/AS703 1,6,10,15,20
A100 DIR OFFICE 101A 3'6" X 5'8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS, FABRIC VALANCE, BLAST-RESISTANT
FILM
-- SH / 1.A 5,6/01.AS703 1,6,7.10,15,20
A101 DIR OFFICE 101A 3'6" X 5'8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- 24" x 14" BLINDS, FABRIC VALANCE, BLAST-RESISTANT
FILM
-- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,7,10,14,15,2
A102 MED CTR OFF 101 3'6" X 5'8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS, FABRIC VALANCE -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A103 MED CTR OFF 101 3'6" X 5'8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- 18" x 14" BLINDS, FABRIC VALANCE -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A104 OFFICE 100 3'6" X 5'8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- 18" x 14" BLINDS, FABRIC VALANCE OUTLET @ RO SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,15,16,20
A105 LOBBY 3' 5" X 5' 10" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A106 LOBBY 3' 5" X 5' 10" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,,15,20
A107 OFFICE 110 3' 6" X 5' 8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- 18" x 14" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A108 OFFICE 109 3' 6" X 5' 8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- 18" x 14" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A109 OFFICE 108 3' 6" X 5' 8" 3' 6" X 6' 0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A110 OFFICE 108 3' 6" X 5' 8" 3' 6" X 6' 0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A111 OFFICE 108 3' 6" X 5' 8" 3' 6" X 6' 0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A200 OFFICE 201C 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A201 OFFICE 201B 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A202 OFFICE 201A 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A203 OFFICE 201A 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A204 OFFICE 200 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A205 OFFICE 200A 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A206 OFFICE 200A 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A207 OFFICE 209 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A208 OFFICE 208 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A209 OFFICE 207 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A210 OFFICE 207 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
A211 CONF RM 206 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
A212 CONF RM 206 3' 7" X 5' 9" 3' 7" X 5' 9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
B001 OFFICE 003 3'2" X 4'2" 3'4" X 4'4" 8" (FURRED OUT 12"-15") DH PAINT WOOD R.O. CLEAR OF CLG -- 18" x 14" BLINDS -- SH / 1.B 3,4/01.AS703 &
3/AS1101
1,6,10,14,15,20
B002 OFFICE 002 3'2" X 4'2" 3'4" X 4'4" 8" (FURRED OUT 12"-15") DH PAINT WOOD R.O. CLEAR OF CLG -- -- BLINDS, PIPE AT TOP OF WINDOW WELL -- SH / 1.B 3,4/01.AS703 1,6,10,15,20
B100 OFFICE 102A 3' 6" X 5' 8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- 24" x 18" BLINDS, FABRIC VALANCE -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
B101 DIR OFFICE 101A 3' 6" X 5' 8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS, BLAST-RESISTANT FILM -- SH / 1.A 5,6/01.AS703 1,6,7,10,15,20
B102 DIR OFFICE 101A 3' 6" X 5' 8" 3' 6" X 6' 0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS, BLAST-RESISTANT FILM -- SH / 1.A 5,6/01.AS703 1,6,7,10,15,20
B200 OFFICE 201 3' 6" X 5' 9" 3' 6" X 6' 0" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
B201 OFFICE 201C 3' 6" X 5' 9" 3' 6" X 6' 0" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C001 OFFICE 012A 3'1" X 2' 6" 3'2" X 2'10" 8" (FURRED OUT 12"-15") FIXED PAINT PAINT DW 1" ABV R.O. -- 18" x 14" AC ONLY, BLINDS OUTLET IN
BUILD OUT
HOP / 1.B 7,8/01.AS703 &
3/AS1101
4,14,6,10,20,35
C002 OFFICE 012 3'1" X 2' 6" 3'2" X 2'10" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- -- BLINDS OUTLET IN
BUILD OUT
SH / 1.B 3,4/01.AS703 1,6,10,15,20
C003 MECH/JC/COMM 011E 3'1" X 3' 3" 3'2" X 2'10" 8" (FURRED OUT 12"-15") FIXED PAINT (CMU) PAINT (CMU) DW 1" ABV R.O. -- -- 1/3 GLAZING & 2/3 METAL INFILL, DUCTWORK IN
FRONT OF WINDOW
-- FXD / 1.G 2,9/01.AS703 &
1,2/AS1101
4,5,6,10,20,35
C004 MECH/JC/COMM 011E 3'1" X 3' 3" 3'2" X 3'3" 8" (FURRED OUT 12"-15") DH PAINT (CMU) PAINT (CMU) R.O. CLEAR OF CLG -- -- METAL INFILL WITH VENT, PIPING ON FRONT OF
WINDOW.
-- FXD / 1.G 2,9/01.AS703 &
1,2/AS1101
4,5,6,10,20,35
C005 STAIR S1 3'3" x 3' 2 1/2" 3'2" X 3'3" 8" (FURRED OUT 12"-15") DH PAINT PAINT R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.B 3,4/01.AS703 1,6,10,15,20
C006 OFFICE 008 3'3" X 3'7" 3'2" X 3'8" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- 18" x 14" BLINDS OUTLET @ RO SH / 1.B 3,4/01.AS703 &
3/AS1101
1,6,10,14,16,20
C007 OFFICE 008 3'3" X 3'7" 3'2" X 3'8" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- -- BLINDS OUTLET @ RO SH / 1.B 3,4/01.AS703 1,6,10,16,20
C008 ELEC 007A 3'3" X 3'7" 3'2" X 3'8" 8" (FURRED OUT 12"-15") DH PAINT (CMU) PAINT (CMU) DW 1" ABV R.O. -- -- PIPES IN FRONT OF WINDOW -- SH / 1.B 3,4/01.AS703 1,6,10,20
C009 RR 005 3'3" X 4'0" 3'2" X 3'8" 8" (FURRED OUT 12"-15") DH PAINT PAINT R.O. CLEAR OF CLG -- -- METAL INFILL WITH LOUVER/EXH FAN , BOTTOM
OF WINDOW BELOW GRADE. PIPING AT TOP OF
OPENING.
CONDUIT TO
FAN
SH / 1.F 3,4/01.AS703 &
1,2/AS1101
5,8,15,20
C010 OFFICE 004 3'3" X 4'0" 3'2" X 3'8" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- 18" x 14" BLINDS, BOTTOM OF WINDOW BELOW GRADE, PIPING AT TOP OF WINDOW.
OUTLET IN
BUILD OUT
SH / 1.B 3,4/01.AS703 &
3/AS1101
1,6,8,10,15,20
C011 OFFICE 003 3'3" X 4'0" 3'2" X 3'8" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- -- BLINDS, BOTTOM OF WINDOW BELOW GRADE -- SH / 1.B 3,4/01.AS703 1,6,10,15,20
C012 OFFICE 003 3'3" X 4'0" 3'2" X 3'8" 8" (FURRED OUT 12"-15") DH PAINT PAINT DW 1" ABV R.O. -- -- BLINDS, PIPING AT TOP OF WINDOW. -- SH / 1.B 3,4/01.AS703 1,6,10,15,20
C013 CLOSET 003E 3'3" X 4'3" 3'2" X 4'4" 8" (FURRED OUT 12"-15") DH PAINT (CMU) PAINT (CMU) DW 1" ABV R.O. -- -- METAL INFILL WITH VENT/ EXH FAN CONDUIT TO
FAN
SH / 1.E 3,4/01.AS703 5,10,20
C101 OFFICE 107 3'6" x 5'8" 3'6" x 6'0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C102 OFFICE 107 3'6" x 5'8" 3'6" x 6'0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C103 OFFICE 106 3'6" x 5'8" 3'6" x 6'0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- 18" x 14" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
C104 OFFICE 106 3'6" x 5'8" 3'6" x 6'0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C105 OFFICE 105 3'6" x 5'8" 3'6" x 6'0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS, ACCENT TRIM -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C106 OFFICE 105 3'6" x 5'8" 3'6" x 6'0" 13" DH VWC VWC R.O. CLEAR OF CLG -- 18" x 14" BLINDS, ACCENT TRIM -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
C107 RR 104 3'6" x 5'9" 3'6" x 6'0" DH VWC WOOD R.O. CLEAR OF CLG -- -- TOP PANE- METAL INFILL CONDUIT TO
EXH FAN
SH / 1.D 5,6/01.AS703 &
1,2/AS1101
1,5,10,15,20,30
C108 KITCHENETTE 102B 3'6" x 5'8" 3'6" x 6'0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C109 OFFICE 102 3'6" x 5'8" 3'6" x 6'0" 13" DH VWC VWC R.O. CLEAR OF CLG -- 18" x 14" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
C110 OFFICE 102 3'6" x 5'8" 3'6" x 6'0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C111 OFFICE 102A 3'6" x 5'8" 3'6" x 6'0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS, FABRIC VALANCE -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C112 OFFICE 102A 3'6" x 5'8" 3'6" x 6'0" 13" DH VWC VWC R.O. CLEAR OF CLG -- -- BLINDS, FABRIC VALANCE -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
SCALE: 1/4" = 1'-0"
NEW WINDOW ELEVATIONS
SEE SCHEDULE, VIF
SE
E
SC
HE
DU
LE
, V
IF
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SCALE: 1/4" = 1'-0"
NEW WINDOW ELEVATIONS
SEE SCHEDULE, VIF
SE
E
SC
HE
DU
LE
, V
IF
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SEE SCHEDULE,
VIF
SE
E
SC
HE
DU
LE
VI
F
SCALE: 1" = 1'-0"
DEMO WINDOW - HUNG
SCALE: 1" = 1'-0"
NEW WINDOW - HUNG
SCALE: 1" = 1'-0"
DEMO WINDOW - HOPPER
SCALE: 1" = 1'-0"
NEW WINDOW - HOPPER
HEAD
JAMB
SILL
HEAD
JAMB
SILL
APPLIED MUNTIN APPLIED MUNTIN
REMOVE EXISTING WINDOW UNIT
REMOVE EXISTING WINDOW TRIM
REMOVE EXISTING BLOCKING
TEMPORARILY REMOVE
SCREEN
TEMPORARILY REMOVE
SCREEN
REMOVE EXISTING WINDOW UNIT
REMOVE EXISTING WINDOW TRIM
REMOVE EXISTING BLOCKING
REMOVE EXISTING WINDOW UNIT
REMOVE EXISTING WINDOW TRIM
TEMPORARILY REMOVE
SCREEN
REINSTALL/ NEW SECURITY
SCREEN
NEW ALUMINUM INSULATED
GLASS WINDOW UNIT
NEW WOOD OR ALUMINUM
BLOCKING
NEW ALUMINUM PANNING / TRIM
NEW ALUMINUM PANNING /
TRIM
NEW BLOCKING OR PANNING
REINSTALL / NEW SECURITY
SCREENNEW ALUMINUM INSULATED
GLASS WINDOW UNIT
NEW ALUMINUM PANNING / TRIM
NEW ALUMINUM INSULATED
GLASS WINDOW UNIT
NEW ALUMINUM PANNING / TRIM
REMOVE EXISTING PANNING
EXISTING LINTEL(S) TO
REMAIN
REMOVE EXISTING FRAMING /
TRIM
DRYWALL / PLASTER WALL
SURFACE AND CORNER DETAIL TO
REMAIN. DO NOT DAMAGE
DURING CONSTRUCTION.
REMOVE EXISTING WINDOW UNIT
REMOVE EXISTING WINDOW TRIM
REMOVE EXISTING BLOCKING /
BUCKS
REMOVE EXISTING PANNING
REMOVE EXISTING FRAMING
& TRIMREMOVE EXISTING WINDOW UNIT
REMOVE EXISTING WINDOW TRIM
REMOVE EXISTING BLOCKING /
BUCKS
DRYWALL / PLASTER WALL
SURFACE AND CORNER DETAIL TO
REMAIN. DO NOT DAMAGE DURING
CONSTRUCTION.
NEW INTERNAL MUNTIN
EXTERIORINTERIOR
NEW INTERNAL MUNTIN
EXTERIORINTERIOR
REMOVE EXISTING WINDOW UNIT
REMOVE EXISTING WINDOW TRIM
REMOVE EXISTING BLOCKING /
BUCKS
REMOVE EXISTING PANNING
REMOVE EXISTING FRAMING /
TRIM
EXISTING SILL TO REMAIN
DRYWALL / PLASTER WALL
SURFACE AND CORNER DETAIL TO
REMAIN. DO NOT DAMAGE
DURING CONSTRUCTION.
REINSTALL / NEW SECURITY
SCREEN
* APPLY SEALANT AT
PERIMETER OF NEW WINDOW
AND PANNING/TRIM, ALL
SIDES, CONTINUOUS.
NEW ALUMINUM INSULATED GLASS
NEW ALUMINUM INSULATED GLASS
HEAD
JAMB
NEW ALUMINUM PANNING
NEW REMOVABLE INSECT
SCREEN
NEW ALUMINUM INSULATED
GLASS WINDOW UNIT, SASHES
FIXED
NEW 12" THICK SOLID SURFACE
STOOL
NEW WOOD OR ALUMINUM
BLOCKING
NEW ALUMINUM PANNING
NEW ALUMINUM INSULATED
GLASS WINDOW UNIT, SASHES
FIXED
NEW WOOD OR ALUMINUM
BLOCKING EXISTING LINTEL, REMOVE
RUST, PRIME, AND PAINT
EXTERIORINTERIOR
NEW ALUMINUM PANNING &
TRIM
NEW FIXED ALUMINUM
INSULATED GLASS WINDOW
UNIT
* APPLY SEALANT AT
PERIMETER OF NEW WINDOW
AND PANNING/TRIM, ALL
SIDES, CONTINUOUS.
NEW WOOD OR ALUMINUM
BLOCKING
NEW 12" THICK SOLID SURFACE
SILL, SECURE TO WALL OPENING,
PROJECT 1
2" BEYOND FACE OF
WALL (NOTE: NO SILL FOR
WINDOWS BLOCKED OFF AT
INTERIOR)
CLEAN / SCRAPE ALL
CAULKING, PAINT, AND OTHER
DEBRIS FROM EXISTING SILL
NEW REMOVABLE INSECT
SCREEN
NEW WOOD OR ALUMINUM TRIM
EXTERIORINTERIOR
MEETING RAILS
SILL
JAMB
HEAD
EXTERIORINTERIOR
SILL
NEW FIXED ALUMINUM
INSULATED GLASS WINDOW
UNIT
EXTERIORINTERIOR
EXTERIORINTERIOR
EXTERIORINTERIOR
NEW REMOVABLE INSECT
SCREEN
SCALE: 1" = 1'-0"
DEMO WINDOW - PARTIAL LOUVER
SCALE: 1" = 1'-0"
NEW WINDOW - PARTIAL LOUVER
HEAD
JAMB
SILL
MEETING RAIL
JAMB
SILL
REMOVE EXISTING
PANNING
EXISTING LINTEL(S)
TO REMAIN
DRYWALL / PLASTER WALL
SURFACE AND CORNER
DETAIL TO REMAIN. DO NOT
DAMAGE DURING
CONSTRUCTION.
REMOVE EXISTING
BLOCKING/BUCKS
REMOVE EXISTING
PANNING
REMOVE EXISTING
FRAMING & TRIMREMOVE EXISTING WINDOW
UNIT
REMOVE EXISTING WINDOW
TRIM
REMOVE EXISTING
BLOCKING/BUCKS
DRYWALL / PLASTER WALL SURFACE
AND CORNER DETAIL TO REMAIN. DO
NOT DAMAGE DURING
CONSTRUCTION
NEW ALUMINUM
PANNING / TRIM
NEW FIXED ALUMINUM
INSULATED GLASS WINDOW
UNIT
NEW ALUMINUM
PANNING / TRIM
NEW ALUMINUM INSULATED
ALUMINUM GLASS WINDOW
UNIT
NEW SOLID SURFACE SILL
NEW WOOD OR ALUMINUM
BLOCKING
NEW ALUMINUM
PANNING / TRIM
FACTORY INSTALLED MECHANICAL
EQUIPMENT IN NEW WINDOW FRAME
EXISTING LINTEL,
REMOVE RUST,
PRIME AND PAINT
EXTERIORINTERIOR
EXTERIORINTERIOR
EXTERIORINTERIOR
EXTERIORINTERIOR
EXTERIORINTERIOR
REMOVE EXISTING WINDOW
UNIT
REMOVE EXISTING WINDOW
TRIM
REMOVE EXISTING
BLOCKING/BUCKS
REMOVE EXISTING
PANNING
REMOVE EXISTING
FRAMING/ TRIM
EXISTING SILL TO
REMAINDRYWALL / PLASTER WALL
SURFACE AND CORNER DETAIL TO
REMAIN. DO NOT DAMAGE
DURING CONSTRUCTION.
CAULK AROUND PERIMETER
OF MECHANICAL
EQUIPMENT, CONTINUOUS
@ INTERIOR AND EXTERIOR
TEMPORARILY REMOVE EXISTING
VENT, LOUVER, OR OTHER
MECHANICAL EQUIPMENT
TEMPORARILY REMOVE EXISTING
VENT, LOUVER, OR OTHER
MECHANICAL EQUIPMENT
REMOVE EXISTING WINDOW
UNIT NEW FIXED INSULATED
GLASS WINDOW UNIT
FACTORY INSTALLED
MECHANICAL EQUIPMENT
APPLY SEALANT AT
PERIMETER OF NEW
WINDOW AND
PANNING/TRIM, ALL
SIDES, CONTINUOUS.
NEW WOOD OR ALUMINUM
BLOCKING
NEW WOOD OR ALUMINUM
BLOCKING
NEW 12" THICK SOLID
SURFACE SILL, SECURE TO
WALL OPENING CLEAN / SCRAPE
ALL CAULKING,
PAINT, AND OTHER
DEBRIS FROM
EXISTING SILL
HEAD
All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.netVIRIDIAN
ARCHITECTURAL DESIGN INC.
100% BID DOCUMENTS
AS702
1. DIMENSIONS ARE TO EDGE OF WALL OR TO FACE OF WALL UNLESS NOTED
OTHERWISE.
2. BUILDING DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY ALL
DIMENSIONS PRIOR TO BEGINNING OF CONSTRUCTION.
3. GENERAL CONTRACTOR TO COORDINATE ALL ASSOCIATED WORK WITH ALL
SUB-CONTRACTORS.
4. ALL MATERIALS IN DEMOLITION DETAILS INDICATED AS DASHED ARE TO BE
REMOVED, SEE DETAILS ON THE A700 SHEETS. THIS INCLUDES ALL FINISHES AND
MATERIALS NOT SPECIFICALLY CALLED OUT BUT PERTAINING TO THE INTENDED
SCOPE.
5. CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE SITE TO BECOME
FAMILIAR WITH THE EXISTING CONDITIONS. THESE DRAWINGS SHALL SERVE TO AID
THE CONTRACTOR IN THE EVALUATION OF THE EXTENT OF DEMOLITION : BUT SHALL
NOT BE HELD TO BE ALL INCLUSIVE.
6. CONTRACTORS SHALL FIELD INSPECT ALL DEMOLITION WORK PRIOR TO REMOVAL,
TO INSURE SUCH REMOVAL DOES NOT IMPAIR STRUCTURAL INTEGRITY OF THE
EXISTING BUILDING . IF THE INSPECTION INDICATES THAT THE STRUCTURAL
INTEGRITY MAY BE COMPROMISED, NOTIFY THE ARCHITECT / ENGINEER
IMMEDIATELY.
7. ALL CONTRACTORS ARE RESPONSIBLE FOR CLEANING SITE TO THE BEST OF THEIR
ABILITIES AT THE END OF EACH WORK DAY.
8. THE CONTRACTOR RESPONSIBLE FOR GENERAL DEMOLITION WORK SHALL
COORDINATE WITH THE ELECTRICAL CONTRACTOR, ALL NECESSARY DEMOLITION TO
OCCUR WHERE ELECTRICAL ACCESS WORK MUST TAKE PLACE.
UPON COMPLETION OF ACCESS WORK, THE GENERAL CONTRACTOR SHALL
REPAIR AND REFINISH ACCESS AREAS TO APPEAR AS THOUGH NO ACCESS
WORK HAD OCCURRED.
MATERIALS NECESSARY FOR THIS WORK SHALL BE COMPATIBLE WITH THE
EXISTING CONSTRUCTION AND FINISH MATERIALS AND COLORS SHALL BLEND IN
WITH THE SURROUNDING SURFACES.
CONTRACTORS SHALL COORDINATE ALL DEMOLITION AND RECONSTRUCTION
WORK WITH OTHER TRADES, TO BE ASSURED THAT WORK IN EITHER OF THESE
AREAS IS COMPLEMENTARY TO THE OTHER AND COMPLETE IN ALL RESPECTS.
9. WHERE ANCHORING DEVICES, ADHESIVES OR MASTICS OCCUR ON EXISTING
CONSTRUCTION THEY SHALL BE REMOVED FROM ALL SURFACES, REPAIRED AND
FINISHED TO MATCH ADJACENT SURFACES.
10. CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE
INSTALLATION OF NEW CONSTRUCTION, WHETHER OR NOT IT IS SPECIFICALLY
SHOWN OR NOTED IN THESE DOCUMENTS.
11. ALL CONTRACTORS TO VERIFY STAGING AND STORAGE LOCATIONS OF ALL
MATERIALS AND EQUIPMENT WITH OWNER PRIOR TO BEGINNING OF CONSTRUCTION.
12. THE GC SHALL TEMPORARILY RELOCATE FURNITURE WITHIN THE SPACE AS
NECESSARY TO COMPLETE THE WORK AND REINSTALL IN ITS ORIGINAL LOCATION.
THE VA WILL REMOVE OR OTHERWISE SECURE ALL PIH, PPI, AND PERSONAL
PROPRTY. COORDINATE WITH COR.
13. ALL CONTRACTORS RESPONSIBLE FOR ANY DAMAGES CAUSED BY THEM DURING
THE CONSTRUCTION PROCESS. IN THE EVENT OF ANY DAMAGES CONTRACTOR IS
TO CONTACT COR IMMEDIATELY; PRIOR TO THE END OF THE DAY OF
CONSTRUCTION.
14. FOR FURTHER INFORMATION WITH REGARD TO THE EXACT EXTENT OF DEMOLITION,
SEE THE CONSTRUCTION PLANS WHICH ILLUSTRATE THE ADJACENT NEW
CONSTRUCTION.
THESE NOTES APPLY TO ALL DEMOLITION DRAWINGS AND TO ALL CONTRACTORS AND / OR
SUBCONTRACTORS THAT WORK WITHIN THIS BUILDING.
AS702
AS702
AS702
AS702
1. REMOVE EXISTING WINDOW UNIT IN ITS ENTIRETY, INCLUDING ALUMINUM SASHES,
FRAMING, PANNING, AND TRIM. REMOVE ANY REMAINING WINDOW MATERIAL
FROM ALL PREVIOUS WINDOW UNITS INCLUDING, BUT NOT LIMITED TO, FRAMING,
FASTENERS, ANCHORS, STOOLS, APRONS, BLOCKING / BUCKS (WOOD AND / OR
METAL) , AND WEIGHTS. TAKE CARE NOT TO DISTURB INTERIOR PERIMETER
PLASTER WORK OR FINISHED DRYWALL ROUGH OPENING. STRUCTURAL ELEMENTS,
INCLUDING HEADERS, LINTELS, AND STRUCTURAL MULLIONS TO REMAIN IN PLACE.
CONCRETE OR MASONRY SILLS TO REMAIN IN PLACE. REMOVE ANY OTHER
MATERIAL PRESENT SO THAT ONLY THE WINDOW ROUGH OPENING, SILL, AND
INTERIOR PERIMETER PLASTER WORK OR FINISHED DRYWALL REMAIN. INSULATE
ANY WALL CAVITIES EXPOSED BY WINDOW REMOVAL. SEE DETAILS AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. REMOVE EXISTING ALUMINUM WINDOW IN ITS ENTIRETY, INCLUDING SASHES,
FRAMING, AND ANY OTHER WINDOW MATERIAL FROM PREVIOUS INSTALLATIONS,
SO THAT ONLY THE ROUGH MASONRY OPENING REMAINS. SEE DETAILS FOR
ADDITIONAL INFORMATION.
3. REMOVE WINDOW AND / OR WALL INFILL MATERIAL TO ROUGH OPENING
INCLUDING CLADDING, BRICK, STUDS, INSULATION, DRYWALL, WINDOWS, AND
ANY OTHER MATERIALS. SEE DETAILS FOR ADDITIONAL INFORMATION.
4. REMOVE INFILL PANEL OR DOOR PANEL AND ANY FRAMING MATERIAL FROM
WINDOW OPENING SO THAT ONLY A ROUGH MASONRY OPENING (WITH LENTIL)
REMAINS. SEE DETAILS FOR ADDITIONAL INFORMATION.
5. LOUVER, VENT, OR OTHER MECHANICAL DEVICE TO REMAIN IN OPENING.
TEMPORARILY DISCONNECT FROM MECHANICAL EQUIPMENT AND ELECTRICAL
SERVICE. TEMPORARILY SUPPORT FOR REMOVAL OF WINDOW ABOVE OR BELOW
IN SAME WINDOW OPENING. INSTALL NEW FRAMING SUPPORT FOR EQUIPMENT.
INSTALL NEW ALUMINUM DOUBLE-GLAZED INSULATED WINDOW IN REMAINING
OPENING. SEE WINDOW SCHEDULE AND DETAILS FOR ADDITIONAL INFORMATION.
6. PROVIDE AND INSTALL NEW DOUBLE-GLAZED INSULATED ALUMINUM WINDOW
UNIT. SIZE TO FIT INTO ROUGH OPENING. WINDOW TO OPERATE AS INDICATED ON
WINDOW SCHEDULE. SEE WINDOW SCHEDULE FOR APPROXIMATE DIMENSIONS
AND DETAILS. SEE SPECIFICATION FOR ADDITIONAL INFORMATION. CONTRACTOR
TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS.
7. PROVIDE AND INSTALL BLAST RESISTANT WINDOW FILM ON ALL SASHES OF THIS
WINDOW UNIT. PRODUCT BASIS OF DESIGN: 3M ULTRA 800 OR EQUAL
APPROVED BY THE VA. SEE SPECIFICATION FOR ADDITIONAL INFORMATION.
8. RELOCATE ELECTRICAL OUTLET AND REROUTE IN-WALL CONDUIT FROM J-BOX OR
PANEL TO NEW ADJACENT LOCATION OUTSIDE AREA OF WINDOW REPLACEMENT.
9. ADJUST INTERIOR HVAC DUCTING SO THAT VENT OCCURS AT TOP SASH.
10. PROVIDE AND INSTALL NEW 1/2" THICK SOLID SURFACE WINDOW STOOL. SEE
FINISH SCHEDULE, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
11. PROVIDE AND INSTALL NEW SECURITY SCREEN AT WINDOW INTERIOR TO REPLACE
EXISTING. NEW SECURITY SCREEN SHALL CONFORM TO VA SECURITY DESIGN
GUIDE. SECURITY SCREEN SHALL REMAIN FUNCTIONAL EXCEPT WHEN BEING
REPLACED. CONTRACTOR SHALL REMOVE AND REPLACE SECURITY SCREEN
DURING WORKING HOURS. WINDOW SHALL NOT BE LEFT UNSECURED AT ANY
TIME.
12. REMOVE SECURITY SCREEN AND ALL ASSOCIATED HARDWARE FROM EXTERIOR
OR INTERIOR OF WINDOW. TEMPORARILY CATALOGUE AND STORE FOR
REINSTALLATION. CLEAN, REFINISH, AND REINSTALL AT SAME LOCATION AFTER
CORRESPONDING WINDOW HAS BEEN INSTALLED. PROVIDE ANY ADDITIONAL TRIM
AND HARDWARE REQUIRED FOR COMPLETE AND SECURE INSTALLATION.
13. PROVIDE AND INSTALL NEW EXTERIOR SECURITY SCREEN TO MATCH ADJACENT.
FINISH TO MATCH ADJACENT.
14. REMOVE AND TURN WINDOW AIR CONDITIONING UNIT (AC) OVER TO VA
MECHANICAL MAINTENANCE SHOP DURING CONSTRUCTION, COORDINATE WITH
COR. CLEAN AC UNIT (INTERIOR AND EXTERIOR), AND REINSTALL FOLLOWING
CORRESPONDING WINDOW REPLACEMENT WITH COMMERCIAL GRADE MOUNTING
BRACKET, GASKETS, 1" INSULATED PANEL, WEATHERPROOFING, FASTENERS, AND
OTHER MATERIALS AS SHOWN IN AC MOUNTING DETAIL 3/AS1101. INSTALL
EXISTING AC UNIT AND CAULK AROUND ALL EDGES TO ELIMINATE AIR INFILTRATION
THROUGH WINDOW OPENING. COORDINATE WITH COR.
15. REMOVE ALL BLINDS, CURTAINS, SHADES, AND ASSOCIATED HARDWARE IN THEIR
ENTIRETY. PROVIDE AND INSTALL NEW 1" ALUMINUM HORIZONTAL BLINDS AND
CORRESPONDING HARDWARE. SEE SPECIFICATION FOR ADDITIONAL
INFORMATION.
16. RELOCATE SURFACE MOUNTED ELECTRICAL OUTLET AND SURFACE CONDUIT TO
ADJACENT LOCATION OUTSIDE OF AREA OF WINDOW REPLACEMENT. REWIRE AS
NEEDED FROM J-BOX OR PANEL.
17. CAREFULLY REMOVE DRYWALL OR PLASTER CEILING OR BULKHEAD AS NEEDED
FOR REMOVAL OF WINDOW MATERIAL. CONSTRUCT NEW DRYWALL AND LIGHT
GAUGE STEEL FRAMING POCKET/ BULKHEAD AT CEILING AROUND NEW WINDOW
OPENING. SEE SPECIFICATIONS AND DETAILS 4&5 / AS1101 FOR ADDITIONAL
INFORMATION.
18. CAREFULLY REMOVE PORTION OF WALL AS NECESSARY FOR REMOVAL OF
WINDOW MATERIAL. PATCH AND REPAIR TO MATCH ADJACENT AFTER NEW
WINDOW INSTALLATION.
19. CAREFULLY REMOVE PORTION OF SUSPENDED ACOUSTICAL TILE CEILING AS
NEEDED FOR REMOVAL OF WINDOW MATERIAL. CONSTRUCT NEW DRYWALL AND
LIGHT GAUGE STEEL FRAMING POCKET/ BULKHEAD AT CEILING AROUND NEW
WINDOW OPENING. REPAIR SUSPENDED ACOUSTICAL TILE CEILING AROUND NEW
POCKET/BULKHEAD SO THAT NO GAPS IN THE CEILING REMAIN. SEE
SPECIFICATIONS AND DETAILS 6&7 / AS1101 FOR ADDITIONAL INFORMATION.
20. REPAIR AND RESTORE DRYWALL / PLASTER WALL SURFACES ADJACENT TO
WINDOW OPENING AND REFINISH (PAINT OR WALL COVERING) TO MATCH
ADJACENT.
21. CLEAN ALL ADHESIVES, DEBRIS, CAULKING, OR OTHER MATERIALS FROM
MASONRY OPENING. REFINISH TO MATCH ADJACENT MASONRY WALL.
22. REMOVE SPEAKER WIRING / CONDUIT RUNNING THROUGH EXISTING WINDOW
FRAME. CAP AT INTERIOR FOR FUTURE USE.
23. 1" INSULATED WINDOW GLASS TO BE FROSTED AT UPPER AND LOWER SASHES.
24. 1" INSULATED WINDOW GLASS TO BE FROSTED AT LOWER SASH ONLY.
25. 1" INSULATED WINDOW GLASS TO BE WIRE SAFETY GLASS.
26. REMOVE EXISTING LIGHT FIXTURE AT WINDOW OPENING IN ITS ENTIRETY. CAP
ELECTRICAL. PATCH AND REFINISH CEILING / BULKHEAD TO MATCH ADJACENT.
27. DO NOT DISTURB EXISTING WALL INFILL. ALL WINDOW REPLACEMENT WORK TO BE
PERFORMED FROM THE EXTERIOR FOR HUNG UNITS COVERED BY AN INTERIOR
WALL, LOCK SASHES IN PLACE AND SEAL AROUND ALL EDGES OF OPERABLE
SASH, INTERIOR AND EXTERIOR. SEE DETAILS 1&2 / AS1101.
28. TEMPORARILY REMOVE, CATALOGUE, AND STORE EXISTING BLACKOUT SHADE
AND ALL CORRESPONDING HARDWARE INCLUDING CEILING POCKETS, BLACKOUT
CHANNELS, AND MOUNTING DEVICES. CLEAN AND REINSTALL FOLLOWING
CORRESPONDING WINDOW REPLACEMENT. PROVIDE AND INSTALL ANY
ADDITIONAL HARDWARE REQUIRED FOR SECURE LIGHT-BLOCKING INSTALLATION.
SEE SPECIFICATION FOR ADDITIONAL INFORMATION.
29. INFILL REMAINING ROUGH OPENING TO MATCH ADJACENT WALL CONSTRUCTION.
30. PROVIDE FROSTED GLASS AT RESTROOM HALF OF WINDOW ONLY.
31. PROVIDE DOOR AT HALF OF WINDOW OPENING AS INDICATED ON THE ELEVATION
AND DETAIL DRAWINGS.
32. PROVIDE NEW DECORATIVE DOUBLE-GLAZED INSULATED ALUMINUM WINDOW
WITH APPLIED MUNTINS. SEE WINDOW SCHEDULE FOR ADDITIONAL INFORMATION
AND DETAILS.
33. 1" INSULATED GLASS TO BE COLORED AT TOP PANE. COLOR TO MATCH EXISTING.
34. REMOVE CONDUIT ADJACENT TO WINDOW. RELOCATE SO NOT TO INTERFERE
WITH WINDOW OPENING.
35. INSULATED INFILL PANEL TO BE GLAZED INTO WINDOW SASH INDICATED IN
DRAWING. CUT OPENING IN INFILL PANEL AS NEED FOR RE-INSTALLATION OF
MECHANICAL EQUIPMENT, LOUVER, OR VENT. RECONNECT EQUIPMENT, LOUVER,
OR VENT AT THE INTERIOR AND ALIGN WITH ALL EXISTING ADJACENT DUCTWORK
OR OTHER MECHANICAL EQUIPMENT.
36. INTERIOR METAL SECURITY SCREEN TO BE REPLACED. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
37. CONTRACTOR TO PROTECT FLOOR. COORDINATE WITH COR.
SH SINGLE HUNG
DH DOUBLE HUNG
FXD FIXED
CASE CASEMENT
HOP HOPPER
AWN AWNING
SL SLIDER
HS HORIZONTAL SLIDER
ALS ALUMINUM STOREFRONT
DC DROPPED CEILING (ACT)
ACT ACOUSTICAL TILE CEILING
DW DRYWALL / PLASTER
RO ROUGH OPENING
BO BOTTOM OF
TO TOP OF
WC WALL COVERING
VWC VINYL WALL COVERING
WD WOOD
SCRN SCREEN
MTL METAL
SS SOLID SURFACE
CT CERAMIC TILE
VIF VERIFY IN FIELD
NOTE:
ASBESTOS ABATEMENT: THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL
CONFIRMATION TESTING AND ABATEMENT OF HAZARDOUS MATERIALS IN
RENOVATION AREAS. SEE SPECIFICATIONS, EXISTING ASBESTOS SURVEY, AND ACM
TABLE ON SHEET GI004 FOR ADDITIONAL INFORMATION. COORDINATE WITH COR.
NOTE:
LEAD CONTAINING PAINT SUSPECTED IN ALL BUILDINGS. CONTRACTOR IS
RESPONSIBLE FOR ALL TESTING AND ABATEMENT OF LEAD PAINT.
NOTE:
CONTRACTOR TO REMOVE ALL RUST IN ITS ENTIRETY FROM STEEL LINTELS AND
PRIME AND PAINT WHITE TO MATCH NEW WINDOW. SEE SPECIFICATIONS FOR
ADDITION INFORMATION.
NOTE:
WINDOW DRAWINGS DO NOT REPRESENT A SPECIFIC PRODUCT OR MANUFACTURER.
THEY INTEND TO DESCRIBE WINDOW TYPES, GENERAL FEATURES, AND GENERAL
INSTALLATION REQUIREMENTS. ALL MEASUREMENTS AND EXISTING CONDITIONS
MUST BE VERIFIED IN FIELD BY THE CONTRACTOR. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
NOTE:
WINDOW MUNTINS TO BE 7
8" WIDE AND LOCATED BETWEEN IGU GLASS LAYERS ONLY.
RESULTING "DIVIDED" LITES SHALL BE APPROX. 9"-12" WIDE. SEE WINDOW
ELEVATIONS FOR GUIDANCE. ALL WINDOW MUNTIN DIMENSIONS AND LOCATIONS TO
BE INDICATED IN SHOP DRAWINGS FOR REVIEW BY THE VA AND ARCHITECT.
NOTE:
NOT ALL WINDOW REPLACEMENT NOTES APPEAR ON THIS SHEET.
NOTE:
ALL WINDOW FRAME DEPTHS TO MATCH EXISTING.6
AS702
AS702
ROOM INTERIOR ROUGH OPENING EXTERIOR ROUGH OPENING WALL THICKNESS OPERATION FINISHES SILL SIZE & TYPE CEILING CONDITION SECURTIY SCREEN A/C OPENING ADDITIONAL COMMENTS ELECTRICAL ELEVATION /
OPERATION
DETAILS REMARKS
C200 CONF RM 206 3'7" x 5'9" 3'6" x 6'0" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C201 CONF RM 206 3'7" x 5'9" 3'6" x 6'0" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C202 OFFICE 205 3'7" x 5'9" 3'6" x 6'0" 13" DH VWC WOOD R.O. CLEAR OF ACT -- 18" x 14" BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
C203 OFFICE 205 3'7" x 5'9" 3'6" x 6'0" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS, WD CASEWORK DATA CABLE
THRU FRAME
SH / 1.A 5,6/01.AS703 1,6,10,15,20
C204 STAIR S1 3'7" x 5'9" 3'6" x 6'0" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- WD CASEWORK -- SH / 1.A 5,6/01.AS703 1,6,10,20
C205 OFFICE 204 3'7" x 5'9" 3'6" x 6'0" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C206 OFFICE 204 3'7" x 5'9" 3'6" x 6'0" 13" DH VWC WOOD R.O. CLEAR OF ACT -- 24" x 14" BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
C207 FILE RM 204A 3'7" x 5'9" 3'6" x 6'0" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- -- SHADE, WD CASEWORK -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C208 RR 202 3'7" x 5'9" 3'6" x 6'0" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- -- WD CASEWORK,TOP PANE-
METAL INFILL
CONDUIT TO
EXH FAN
SH / 1.D 5,6/01.AS703 &
1,2/AS1101
1,5,10,20,30
C209 OFFICE 201 3'7" x 5'9" 3'6" x 6'0" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- -- BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
C210 OFFICE 201 3'7" x 5'9" 3'6" x 6'0" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- 18" x 14" BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
C211 OFFICE 201 3'7" x 5'9" 3'6" x 6'0" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- 18" x 14" BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
C212 OFFICE 201 3'7" x 5'9" 3'6" x 6'0" 13" DH PAINT WOOD R.O. CLEAR OF ACT -- -- BLINDS, WD CASEWORK -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
D001 OFFICE 013A 3'1" x 2'0" 3'2" x 2'5" 8" (FURRED OUT 12"-15")
DH PAINT PAINT -- -- BLINDS, PIPE AT TOP OF
WINDOW WELL
-- HOP / 1.C 7,8/AS703 1,6,10,15,20
D100 OFFICE 108 3'7" x 5'8" 3'6" x 6'0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- 18" x 14" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
D101 OFFICE 107 3'6" x 5'8" 3'6" x 6'0" 13" DH PANELING WOOD R.O. CLEAR OF CLG -- 24" x 18" BLINDS -- SH / 1.A 5,6/01.AS703 &
3/AS1101
1,6,10,14,15,20
D200 CONF RM 206 3'7" x 5'9" 3'7" x 5'9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
D201 CONF RM 206 -- 3'7" x 5'9" 13" -- -- -- -- -- -- INTERIOR INFILLED- NO
ACCESS
-- SH / 1.A 5,6/01.AS703 1,6,27
D202 CONF RM 206 3'7" x 5'9" 3'7" x 5'9" 13" DH VWC WOOD R.O. CLEAR OF ACT -- -- BLINDS -- SH / 1.A 5,6/01.AS703 1,6,10,15,20
| 2 |
| 08 515-14-103.01-AS701 |
| Sheets and Views |
| AS701 |
| 09 515-14-103.01-AS702 |
| Sheets and Views |
| AS702 |
| 10 515-14-103.03-AS401 |
| Sheets and Views |
| AS401 |