36C24818Q0491-009.pdf
PDF 3 MB Posted
- Attached to
- Services: Repair Active Vehicle Barriers Federal contract opportunity
- Solicitation number
- 36C24818Q0491
About this file
36C24818Q0491 ATTACHMENT B Warehouse Service barrier Survey v3-.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24818Q0491-00001001.docx | DOCX document | |
| 36C24818Q0491-00001000.docx | DOCX document | |
| 36C24818Q0491-008.pdf | ||
| 36C24818Q0491-012.pdf | ||
| 36C24818Q0491-006.pdf | ||
| 36C24818Q0491-003.pdf | ||
| 36C24818Q0491-007.pdf | ||
| 36C24818Q0491-011.pdf | ||
| 36C24818Q0491-002.docx | DOCX document | |
| 36C24818Q0491-004.pdf | ||
| 36C24818Q0491-005.pdf | ||
| 36C24818Q0491-013.pdf | ||
| 36C24818Q0491-010.pdf | ||
| 36C24818Q0491-001.docx | DOCX document | |
| 36C24818Q0491-000.docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Warehouse Service barrier Survey v3.docx
Warehouse Service Entrance - Outbound Side Lane
General Notes:
-Limit Sensors wiring is damaged not properly terminated for below grade application. The cable should be shortened, terminations should be soldiered, adhesive heat shrunk, and cable sleeved Lead in cables are damaged and need replaced with shielded cable
Warehouse Service Entrance - Middle Lane
General Notes:
-Limit Sensors wiring is damaged and not properly terminated for below grade application. The cable should be shortened, terminations should be soldiered, adhesive heat shrunk, and cable sleeved
-Hose needs replaced and rerouted. We moved it back slightly to avoid rubbing.
Ware Service Entrance - Left/Middle – Power Unit
General Notes:
-Hydraulic oil is extremely dirty. The oil, suction strainer needs to be replaced. The hydraulic hoses need to be blown out and flushed. The hydraulic drum needs to be wiped and cleaned thoroughly
-Eliminate the un-necessary secondary layer of PLC control
-Noticeable rusting and paint chipping is on the outdoor enclosure. The chipping spots at a minimum needs to be touched up. Full painting is suggested.
-Lid is cracked, replace with OEM reservoir lid
Warehouse Service Entrance - Inbound Side Lane
General Notes:
-Hydraulic oil is extremely dirty. The oil, suction strainer needs to be replaced. The hydraulic hoses replaced and shortened up. The hydraulic drum needs to be wiped and cleaned thoroughly
- Eliminate the un-necessary secondary layer of PLC control
-Front Rubber pad starting to come off. Needs to be replaced
-Concrete pad under the barrier needs to be repaired.
-Limit Sensors wiring is not properly terminated for below grade application. The cable should be shortened, terminations should be soldiered, adhesive heat shrunk, and cable sleeved
-limit wire damaged replace with shielded cable
-Noticeable rusting and paint chipping is on the outdoor enclosure. Full painting is suggested.