36C24818Q0491-006.pdf

PDF 2 MB Posted

Attached to
Services: Repair Active Vehicle Barriers Federal contract opportunity
Solicitation number
36C24818Q0491
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

36C24818Q0491 ATTACHMENT B South West Service Barriers Survey v3-.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Services: Repair Active Vehicle Barriers, newest first.
File Type Posted
36C24818Q0491-00001000.docx DOCX document
36C24818Q0491-00001001.docx DOCX document
36C24818Q0491-009.pdf PDF
36C24818Q0491-008.pdf PDF
36C24818Q0491-012.pdf PDF
36C24818Q0491-003.pdf PDF
36C24818Q0491-007.pdf PDF
36C24818Q0491-011.pdf PDF
36C24818Q0491-002.docx DOCX document
36C24818Q0491-004.pdf PDF
36C24818Q0491-005.pdf PDF
36C24818Q0491-013.pdf PDF
36C24818Q0491-010.pdf PDF
36C24818Q0491-001.docx DOCX document
36C24818Q0491-000.docx DOCX document
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Service Entry – South West barriers

Concrete was poured too high during installation resulting in the plate not resting properly in the down position and also damaging the paint and the galvanizing coating

Resolution: grind the concrete down, touch up paint with yellow and black paint

Concrete Slurry on top of barrier ram remove slurry and repaint

Concrete was poured too high during installation resulting in the plate not resting properly in the down position and also damaging the paint and the galvanizing coating

Oil dirty but manifold is in good shape. Less leaking down valve

Remove additional layer of controls

Concrete was poured too high during installation resulting in the plate not resting properly in the down position and also damaging the paint and the galvanizing coating

Secondary layer of controls not necessary remove and control from master panel

Surge protector terminals failing replace with standard terminals and whole unit surge protection

All barrier programming & control migrated to this control group