List - C Inferred Scanning Perry Point.pdf
PDF 137 KB Posted
- Solicitation number
- 36C24520Q0539
About this file
This solicitation requests proposals for maintenance, inspection, and testing of the electrical power distribution system at the Perry Point VA Medical Center in Maryland. The one-year contract will provide electric distribution and testing services in accordance with the attached statement of work. Proposals are due by the date and time specified on the SF1449 form. This is a tiered evaluation with priority given to service-disabled veteran-owned small businesses, then veteran-owned small businesses, and then other small businesses, with preference to HUBZone and 8(a) participants. The North American Industry Classification System code for this procurement is 238210 for electrical contractors with a business size standard of $16.5 million. All inquiries must be submitted in writing to the specified contracting officer by email.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24520Q0539 0002_1.docx | DOCX document | |
| PP Vistor Guide Site Map 2019 (002).pdf | ||
| List - B1 Transformers 4-ea replace oil.pdf | ||
| List - B Transformers to be tested Perry Point.pdf | ||
| 36C24520Q0539 0001_1.docx | DOCX document | |
| Perry Point to building 101 -by truck entrance (002).pdf | ||
| 36C24520Q0539 0001_1 02.docx | DOCX document | |
| List - A1 Breakers to be Replaced Perry Point.pdf | ||
| List D Transformer Report by ACV ENVIRO 9-27-2019.pdf | ||
| List - A Breakers to be Tested Perry Point.pdf | ||
| 36C24520Q0539_2.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
List C Infrared Scanning Perry Point
Emergency Generator Location
# of
ATS
Em-Gen Serves
Buildings Building Function
Infrared/scan Main Distribution Panel this Building:
Infrared/scan 4-each *sub-panels this Building:
20G 1 20G Water Pumping Station 20G 20G
103A
103B
360G 1 26 Fire House 26 26
23H 1 23H Patient Care 23H 23H
311G 1 211 Sewage Pump Station 211 211
315 Boiler Plant Chiller Plant) 315 315
321 Chiller Plant 321 321
1 3H Admin 3H 3H
1 4H Admin 4H 4H
1 5H Admin 5H 5H
1 1H Patient Care 1H 1H
1 2H vacant 2H 2H
1 17H Kitchen (N&FS) feeds17H 17H 17H
1 13H IRM-Admin 13H 13H
1 14H Patient Care 14H 14H
1 24H vacant 24H 24H
1 25H vacant 25H 25H
329G 1 22H Patient Care 22H 22H
333G 2 20H Telephone Operator and
Main Computer Room 20H 20H
9H NCCC (admin) 9H 9H
Recreation, Pool, Theater:
lights only 314 314
361G 4 361 Clinical Services 361 361
365H 2 364 Patient Care 364 364
19H 2 19H Patient Care 19H 19H
17H 1 17H Kitchen
Nutarian &Food Service 17H 17H
Main Distribution Panels 18 each sub-panels (4 x 18) 72 each
Inferred Scan Total 90 each
327G
1031 103 New Water Treatment Plant
315G 1
324G
344G
* Sub-panels location in building to be determine by COR
325G
Infra-red scanning