List - A Breakers to be Tested Perry Point.pdf
PDF 134 KB Posted
- Solicitation number
- 36C24520Q0539
About this file
This document contains a list of 74 electrical breakers at the Perry Point VA Medical Center in Maryland that require either replacement or testing. It also includes a related federal contract opportunity posted by the Department of Veterans Affairs for maintenance, inspection, and testing services of the center's electrical power distribution system.
The solicitation seeks quotations for providing electric distribution and testing services at the Perry Point VA Medical Center in accordance with the attached statement of work. Key details include a one-year period of performance for the contract, a submission deadline of the date and time specified on the SF1449, and applicable NAICS code 238210 with a $16.5 million size standard. The solicitation will be issued as a tiered evaluation for SDVOSB, VOSB, or small business concerns, with priority for HUBZone and 8(a) participants if no award can be made to higher tiers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24520Q0539 0002_1.docx | DOCX document | |
| PP Vistor Guide Site Map 2019 (002).pdf | ||
| List - B1 Transformers 4-ea replace oil.pdf | ||
| List - B Transformers to be tested Perry Point.pdf | ||
| 36C24520Q0539 0001_1.docx | DOCX document | |
| Perry Point to building 101 -by truck entrance (002).pdf | ||
| 36C24520Q0539 0001_1 02.docx | DOCX document | |
| List - A1 Breakers to be Replaced Perry Point.pdf | ||
| List D Transformer Report by ACV ENVIRO 9-27-2019.pdf | ||
| List - C Inferred Scanning Perry Point.pdf | ||
| 36C24520Q0539_2.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Co un t
Bldg. Location Label Style Device FS Amp
Rating Make Type Serial .
Replace Breaker or
Test Breaker
Night or Day
Work
1 9H High Voltage Vault Main feed- ATS Molder Case Breaker SS 1200 1200 WH NC (Cutler Hammer SNB) Style# 26080776G01, Cat# NC31200F Test Night
2 9H High Voltage Vault LPG Molder Case Breaker EM 400 400 WH DA (Westinghouse Breaker) DA2400Y2 Test Night
3 4R Main Molder Case Breaker EM 800 800 MAL Cat# MAP 36800 Test Night
4 4R High Voltage Vault Service Disconnect. Molder Case Breaker SS 600 600 WH LC (Cutler Hammer MP-40) Cat# LC3600F Test Night
5 364 High Voltage Vault ATS 1 Molder Case Breaker SS 400 GE Spectra RMS (GE SRPK) Replace Day
6 364 G03 DDRP Main Molder Case Breaker SS 800 800 GE SKHA36AT0800 (GE SRPK) Test Day
7 364 G03 225 KVA DTT Molder Case Breaker SS 600 450 GE Spectra RMS (GE SPRK) Test Day
8 364 EMDP-Main Molder Case Breaker SS 600 450 GE SGHA36AT0600 Test Day
9 364 EMDP-ATS Molder Case Breaker SS 400 400 GE SGHA36AT0400 Test Day
10 364 G03 Main integrated circuit breaker (iCB) 1600 1600 GE Power Breaker (TP1616TTEIR)
15664, Cat# TP1616TTE1R Test Day
11 344 9H / NS Air Circuit Breaker (ACB) SS 1600 1600 FPE FPS-50 WSC-117707-3 Replace Night
12 344 9H / ES Air Circuit Breaker (ACB) SS 1600 800 FP FPS50 WSC-1177028 Replace Night
13 329 Gen Bldg. 22H / ES Air Circuit Breaker (ACB) SS 600 600 FPE FPE FPS 25 XSC-1177018 Test Night
14 329 Gen Bldg. 22 HS Air Circuit Breaker (ACB) SS 1600 800 FPE FPS-50 (FPE FPS 25) WSF-1277016 Test Night
15 326 Gen Bldg. 13H / NS Air Circuit Breaker (ACB) SS 1600 1000 FP FPS-50 (FPE FPS 25) WSC-1177007-1 Test Night
16 326 Gen Bldg. 14H / NS Air Circuit Breaker (ACB) SS 1600 1000 FP FPS-50 (FPE FPS 25) WSC-1177007-2 Test Night
17 326 Gen Bldg. Spare Air Circuit Breaker (ACB) SS 1600 1600 FPE FPS-50 (FPE FPS 25) WSF-127704 Test Night
18 325 Gen Bldg. 17H / ES Air Circuit Breaker (ACB) SS 1600 1000 FPE FPE FPS 50 WSC-11702-7 Test Night
19 324 Gen Bldg. SH / NS Air Circuit Breaker (ACB) SS 600 600 FPE FPE FPS 25 XSC-1177005-2 Test Night
List A Breakers to be Tested Perry Point 2020 t
Bldg. Location Label Style Device FS Amp
Rating Make Type Serial .
Replace Breaker or
Test Breaker
Night or Day
Work
List A Breakers to be Tested Perry Point 2020
20 315 Boiler Plant Main (Indoor MDP) miniature circuit breaker
(MCB)
SS 2000 2000 WH PCG
Style# 2609D12G10, Cat# PCG32000F Test Day
21 314 High Voltage Vault EMDP Air Circuit Breaker (ACB) EM 600 400 ITE K-600 (ITE Type K 600) 42993-B22-2-6B Test Night
22 314 High Voltage Vault 314A Air Circuit Breaker (ACB) EM 600 600 ITE K-600 (ITE Type K 600) 42993-820-1-68 Test Night
23 314 High Voltage Vault MDPPB Air Circuit Breaker (ACB) EM 600 350 ITE K-600 (ITE Type K 600) 42993-B22-3-6B Test Night
24 314 High Voltage Vault Spare Air Circuit Breaker (ACB) EM 600 600 ITE K-600 (ITE Type K 600) 42993-820-2-63 Test Night
25 314 High Voltage Vault MDPLB Air Circuit Breaker (ACB) EM 600 350 ITE K-600 (ITE Type K 600) 42993-B22-1-6B Test Night
26 314 High Voltage Vault LP-314C Air Circuit Breaker (ACB) EM 600 225 ITE K-600 (ITE Type K 600) 42993-B24-1-6B Test Night
27 2H Room 102 MCC-Basement miniature circuit breaker
(MCB)
EM 800 700 SqD LA (SQ D Type EI) Test Night
28 25H Outside Vault Otsd Sub Stn Bldg. Air Circuit Breaker (ACB) SS 1600 1600 SqD DS-416 (SQ D PAF 2036) 48Y4275 Test Night
29 25H Mn Elec Rm 25 H MDP Main miniature circuit breaker
(MCB)
EM 2000 1600 SqD PAL Cat# PAF2036 Test Night
30 24H Room 23 Main miniature circuit breaker
(MCB)
EM 2000 1600 SqD PAL (SQ D PS-2 Panel) Cat# PAF-361600 Test Night
31 24H Room 23 Main Otdr Brkr Air Circuit Breaker (ACB) SS 1600 1600 SqD DS-416 48Y4275 Test Night
32 23H CC-111 Main WH Substn. Air Circuit Breaker (ACB) SS 2000 2000 WH DS-420 (SB Type DS-420) Test Night
33 23H CC-111 ATS 3 Air Circuit Breaker (ACB) SS 800 400 WH DS-206 (SB Type DS-206) Test Night
34 23H CC-111 ATS 2 Air Circuit Breaker (ACB) SS 800 300 WH DS-206 (SB Type DS-206) Test Night
35 23H #361 Sw Gr LPGB Air Circuit Breaker (ACB) SS 800 800 WH DS-206 (SB Type DS-206) Replace Night
36 23H #361 Sw Gr ATS 1 Air Circuit Breaker (ACB) SS 800 800 WH DS-206 (SB Type DS-206) Replace Night
37 23H Bldg. 23 T-3 Air Circuit Breaker (ACB) EM 600 200 GE AK-2A-25-1 (AKP-S SB) 179A4520-204-HA Test Night
38 23H CC-111 LP1 Air Circuit Breaker (ACB) SS 800 300 WH DS-206 (SB Type DS-206) Test Night
39 23H CC-111 Spare Air Circuit Breaker (ACB) SS 800 800 WH DS-206 (SB Type DS-206) Test Night t
Bldg. Location Label Style Device FS Amp
Rating Make Type Serial .
Replace Breaker or
Test Breaker
Night or Day
Work
List A Breakers to be Tested Perry Point 2020
40 23H #361 Sw Gr XRPI Air Circuit Breaker (ACB) SS 800 300 WH DS-206 (SB Type DS-206) Replace Night
41 23H #361 Sw Gr LPGA Air Circuit Breaker (ACB) SS 800 800 WH DS-206 (SB Type DS-206) Test Night
42 23H CC-111 ME1 Air Circuit Breaker (ACB) SS 800 300 WH DS-206 (SB Type DS-206) Test Night
43 23H CC-111 Main Air Circuit Breaker (ACB) EM 1600 100 GE AK-2A-50 (AKP-S Main) 179A4520-201-HA Replace Night
44 23H CC-111 X-Ray RM116 Air Circuit Breaker (ACB) EM 600 150 GE AK-2A-25-1 (AKP-S SB) 179A4520-205-HA Replace Night
45 23H CC-111 T-6 Air Circuit Breaker (ACB) EM 600 350 GE AK-2A-25-1 (AKP-S SB) 179A4520-203-HA Replace Night
46 23H CC-111 T-1 Air Circuit Breaker (ACB) EM 600 400 GE AK-2A-25-1 (AKP-S SB) 179A4520-202-HA Replace Night
47 23H CC-111 LHB-183 Air Circuit Breaker (ACB) EM 600 125 GE AK-2A-25-1 (AKP-S SB) 179A4520-206-HA Replace Night
48 23H CC-111 MCC Air Circuit Breaker (ACB) EM 600 350 GE AK-2A-25-1 (AKP-S SB) 179A4520-203-HA Replace Night
49 23H #361 Sw Gr MCC-G Air Circuit Breaker (ACB) SS 800 800 WH DS-206 (SB Type DS-206) Test Night
50 23H CC-111 ATS Air Circuit Breaker (ACB) EM 600 200 GE AK-2A-25-1 (AKP-S SB) 179A4520-204-HA Replace Night
51 20 Main miniature circuit breaker
(MCB)
EM 400 4000 SqD LA (SQ D Type EI) Cat# LA 36 400 MT Test Night
52 19H Room 16 DP-4 Air Circuit Breaker (ACB) SS 600 200 ITE K-600 (ITE Type 600K) 18914 Test Night
53 19H Room 16 Panel 1E & 2E Air Circuit Breaker (ACB) SS 600 200 ITE K-600 (ITE Type 600K) 42993-C25-1-6B Test Night
54 19H Room 16 DP-1 Air Circuit Breaker (ACB) EM 600 600 ITE K-600 (ITE Type 600K) 42993-C17-1-6B Test Night
55 19H Room 16 DP-3 Air Circuit Breaker (ACB) EM 600 600 ITE K-600 (ITE Type 600K) 42993-C17-3-6B Test Night
56 19H Room 16 DP-2 Air Circuit Breaker (ACB) EM 600 600 ITE K-600 (ITE Type 600K) 42993-C17-2-6B Test Night
57 19H Room 16 MDP-19H Air Circuit Breaker (ACB) EM 1600 1600 ITE K-1600 42993-C12-1-6B Test Night
58 19H Room 16 Secondary miniature circuit breaker
(MCB)
SS 400 400 GE (GE Sub Panel) Cat# TJ4V2604 Test Night
59 17H High Voltage Vault EMPD Air Circuit Breaker (ACB) EM 600 125 ITE K-DON (ITE K 1600) 42993-A16-1-6B Replace Night t
Bldg. Location Label Style Device FS Amp
Rating Make Type Serial .
Replace Breaker or
Test Breaker
Night or Day
Work
List A Breakers to be Tested Perry Point 2020
60 17H High Voltage Vault New Kitchen Eq Air Circuit Breaker (ACB) EM 1600 1600 ITE K-1600 (ITE K 1600) 42993-A13-3-6B Replace Night
61 17H High Voltage Vault MDP A Air Circuit Breaker (ACB) EM 1600 1600 ITE K-1600 (ITE K 1600) 42993-A13-1-6B Replace Night
62 17H High Voltage Vault MDP B Air Circuit Breaker (ACB) EM 1600 1600 ITE K-1600 (ITE K 1600) 42993-A13-26B Replace Night
63 15H Room 103 Main miniature circuit breaker
(MCB)
EM 800 800 ITE ITE Type CDP Test Night
64 14H Room 17 MDP-14-2 miniature circuit breaker
(MCB)
SS 600 600 WH LC (Cutler Hammer Type MP-40) Style# 2607078G48, Cat# LC3600G Test Night
65 14H Room 17 MDP-14 HB miniature circuit breaker
(MCB)
SS 600 600 WH LC (Cutler Hammer Type SLB) Style# 2607078G48, Cat# LC3600F Test Night
66 11W Warehouse High
Voltage Vault Main Air Circuit Breaker (ACB) EM 1600 1600 ITE
K-1600 (ITE WT J7F3204
Clampmatic)
S1715-A-2 Test Night
67 101 Room 14 Main Breaker miniature circuit breaker
(MCB)
EM 1200 1200 WH NB 4997D20602 NB31200F Test Night
68 101 Transformer Main Otdr Brkr miniature circuit breaker
(MCB)
EM 2500 1400 FPE NP Cat# NP632000 Test Night
69 344 Gen Bldg.- 2W-3E
Electrical Loop
9H/NS
miniature circuit breaker
(MCB)
EM DA2400Y2 Replace Night
70 326 Gen Bldg.- 2W-3E
Electrical Loop 14H /ES Air Circuit Breaker (ACB) SS 1600 1600 FPE FPS-50 (FPE FPS 25) WSF-127704 Test Night
71 324 Gen Bldg.- 2W-3E
Electrical Loop 3H/ ES Test Day
72 324 Gen Bldg.- 2W-3E
Electrical Loop 4H/ES Test Day
73 324 Gen Bldg.- 2W-3E
Electrical Loop 5H/ES Test Day
74 324 Gen Bldg.- 2W-3E
Electrical Loop 3H/ NS Test Night
75 324 Gen Bldg.- 2W-3E
Electrical Loop 4H/NS Air Circuit Breaker (ACB) SS 600 600 FPE FPE FPS 25 X-10670451 Test Night
Breaker Test List 2020