Attachment A-603.pdf
PDF 328 KB Posted
- Solicitation number
- 36C24223B0048
About this file
This document is an engineering drawing and related federal contract opportunity for upgrading access controls at a Veterans Affairs medical center. The engineering drawing depicts the ground floor plan of Building 10 and includes keyed notes specifying the scope of work. The contractor will be required to install new card readers, approximately 1100 feet of metallic conduit and cable, and replace existing double doors to upgrade access controls at entrances including the sidewalk, S1X1 door, loading dock, room 101, and street side double doors. The related federal contract opportunity is solicitation number 36C24223B0048 to upgrade access controls station wide for the Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2. The anticipated award date is unspecified. Pricing terms and set-asides are not included in the provided information.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| REV. 1 SOW 23-506-Upgrade Access Control.docx | DOCX document | |
| Attachment Spec section 08 71 00.pdf | ||
| All drawing.pdf | ||
| Attachnent - General Note.pdf | ||
| S04 - Sign in - Pre-Bid Access Control.pdf | ||
| All Specification.pdf | ||
| S04 - Sign in - Pre-Bid Access Control Oct 19 2023.pdf | ||
| QandA_528A5-23-506_upgrade Access Control.xlsx | XLSX spreadsheet | |
| 852.219-75 VA Notice of Limitations on Subcontracting.pdf | ||
| Attachment - TOC.pdf | ||
| 36C24223B0048 0001.docx | DOCX document | |
| P07 Wage Determination.pdf | ||
| S02 All Drawing.pdf | ||
| S02 All Spec.pdf | ||
| 013200 Construction Documentation.pdf | ||
| 36C24223B0048_1.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LINEN STORAGE AREA
C R
CR
C R
CR
CR
PS
BUILDING 10 - GROUND FLOOR PLAN
LAUNDRY
CANANDAIGUA, NEW YORK
4/24/2023 RARB
100% CONSTRUCTION
DOCUMENTS
A-603
10A o n e e ig h th in ch o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
A
2 3 4 5 7 8
B
C
D
E
6 9
1 2 3 4 5 7 86 9
A
B
C
D
E
Bl dg fi rs t.d w g
[L
AY
O U
T:
2x
-1 0A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
VA MEDICAL
CENTER
ENGINEERING
CANANDAIGUA /
BATH, NEW YORK
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
No. Revision: Date:
NOTE:
USERS OF THESE DRAWINGS ARE RESPONSIBLE FOR VERIFYING EXISTING DIMENSIONS AND
CONDITIONS IN THE FIELD.
SCALE: (FOR REFERENCE ONLY)
/1
1/
:2 6:
P
M
AN
SI
D
: 2 2" x
4"
528A5-23-506UPGRADE ACCESS CONTROL
STATION WIDE
CANANDAIGUA, VAMC
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
UP
AutoCAD SHX Text 4'
AutoCAD SHX Text Sidewalk
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text S1X1
AutoCAD SHX Text
-UPPER LEVEL-
AutoCAD SHX Text
LOADING DOCK
AutoCAD SHX Text
AutoCAD SHX Text
LOADING DOCK
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
UP
AutoCAD SHX Text KEYED NOTES: 1. PROVIDE AND INSTALL NEW POWER SUPPLY AND ANY PROVIDE AND INSTALL NEW POWER SUPPLY AND ANY ASSOCIATED EQUIPMENT FOR A NEW INSTALLATION IN THE OFFICE. 2. PROVIDE AND INSTALL NEW CARD READER ON SIDEWALK DOOR, PROVIDE AND INSTALL NEW CARD READER ON SIDEWALK DOOR, SIX1 DOOR,DOUBLE DOOR (STREET SIDE),LOADING DOCK DOOR, ROOM 101 THE SINGLE DOOR, WITH PIV CLASS ( RKCL40-P C/CL LCD KEYPAD READER) AND ALL ASSOCIATED EQUIPMENT FOR A NEW INSTALLATION.REFER TO (A-702-1,2) FOR DOOR DETAILERS . 3. PROVIDE AND INSTALL APPROXIMATELY (110FT) OF " METALLIC PROVIDE AND INSTALL APPROXIMATELY (110FT) OF " METALLIC 34" METALLIC TUBING CONDUIT STARTING FROM THE OFFICE TO SIDEWALK ENTRANCE. 4. PROVIDE AND INSTALL APPROXIMATELY (110FT) OF ACCESS PROVIDE AND INSTALL APPROXIMATELY (110FT) OF ACCESS CONTROL CABLE (658AMS) FROM FROM THE OFFICE ROOM TO FROM THE OFFICE ROOM TO SIDEWALK ENTRANCE. . 5. PROVIDE AND INSTALL APPROXIMATELY (60FT) OF 1' " METALLIC PROVIDE AND INSTALL APPROXIMATELY (60FT) OF 1' " METALLIC 14" METALLIC TUBING CONDUIT STARTING FROM THE OFFICE TO THE CONDUIT BOX TO REACHED THE S1X1 ENTRANCE . . 6. PROVIDE AND INSTALL APPROXIMATELY (20FT) OF " METALLIC PROVIDE AND INSTALL APPROXIMATELY (20FT) OF " METALLIC 34" METALLIC TUBING CONDUIT STARTING FROM THE BOX TO REACHED THE S1X1 ENTRANCE CARD READER REFER TO (A-702-4,5) . (A-702-4,5) . . 7. PROVIDE AND INSTALL APPROXIMATELY (80FT) OF ACCESS PROVIDE AND INSTALL APPROXIMATELY (80FT) OF ACCESS CONTROL CABLE (658AMS) FROM THE OFFICE ROOM TO S1X1 THE OFFICE ROOM TO S1X1 ENTRANCE. 8. PROVIDE AND INSTALL APPROXIMATELY (220FT) OF 1' METALLIC PROVIDE AND INSTALL APPROXIMATELY (220FT) OF 1' METALLIC TUBING CONDUIT STARTING FROM THE S1X1 CONDUIT BOX TO REACHED THE CONDUIT BOX OF 101 SINGLE DOOR ENTRANCE. 9. PROVIDE AND INSTALL APPROXIMATELY (290FT) OF ACCESS PROVIDE AND INSTALL APPROXIMATELY (290FT) OF ACCESS CONTROL CABLE (658AMS) FROM THE OFFICE ROOM TO 101 THE OFFICE ROOM TO 101 SINGLE DOOR ENTRANCE CARD READER. 10. PROVIDE AND INSTALL APPROXIMATELY (40FT) OF " METALLIC PROVIDE AND INSTALL APPROXIMATELY (40FT) OF " METALLIC 34" METALLIC TUBING CONDUIT STARTING FROM THE 101 SINGLE DOOR BOX TO REACHED THE LOADING DOCK ENTRANCE CARD READER. . 11. PROVIDE AND INSTALL APPROXIMATELY (330FT) OF ACCESS PROVIDE AND INSTALL APPROXIMATELY (330FT) OF ACCESS CONTROL CABLE (658AMS) FROM THE OFFICE ROOM TO THE FROM THE OFFICE ROOM TO THE LOADING DOCK SINGLE DOOR ENTRANCE CARD READER. . 12. PROVIDE AND INSTALL APPROXIMATELY (60FT) OF 1' METALLIC PROVIDE AND INSTALL APPROXIMATELY (60FT) OF 1' METALLIC TUBING CONDUIT STARTING FROM THE OFFICE ROOM TO REACHED THE DOUBLE DOOR STREET SIDE ENTRANCE AND THE BASEMENT DOORS. 13. PROVIDE AND INSTALL APPROXIMATELY (60FT) OF ACCESS PROVIDE AND INSTALL APPROXIMATELY (60FT) OF ACCESS CONTROL CABLE (658AMS) FROM THE OFFICE ROOM TO THE FROM THE OFFICE ROOM TO THE DOUBLE DOOR STREET SIDE ENTRANCE CARD READER. 14. REPLACE THE EXISITING DOUBLE DOORS FOR THE STREET SIDE REPLACE THE EXISITING DOUBLE DOORS FOR THE STREET SIDE ENTRANCE TO NEW DOOR MEET ALL SPECIFICATIONS REQUIREMENTS REFER TO (A-702-2) FOR DOOR GENERAL DETAILS .